Loading...
31C-081 0 ir)1 - ZZ BP-2021-2344 117OLANDER PHASE 4 COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 3 I C-081-027 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2021-2344 PERMISSIONIS HEREBY GRANTED TO: Project# SOLAR Contractor: License: PIONEER VALLEY Est.Cost: 63950 PHOTOVOLTAICS 111266 Const.Class: Exp.Date:03/14/2023 SCH LACK, MARK I &JULIE W TRUSTEES Use Group: Owner: KENNEY, JESSIC L & MILES L STEELE Lot Size (sq.ft.) Zoning: Applicant: PIONEER VALLEY PHOTOVOLTAICS Applicant Address Phone: Insurance: 311 WELLS ST - SUITE B (413)772-8788 375928710101 GREENFIELD, MA 01301 ISSUED ON:12/28/2021 TO PERFORM THE FOLLOWING WORK: 26 ROOF MOUNT PANELS - 19.6KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. • Signature: 861,4m., � 3 Fees Paid: $75.00 212 Main Street,Phone(413) 587-1240,Fax:(413)587-1272 Office of the Building Commissioner Department use only City Of NOrthar, pt0gStatus of Permit: Building Depa4'tme t •if , Curb Cut/Driveway Permit 212 Main tree `Sewer/Septic Availability Room 700 DEC 8 Water/Well Availability NOrthamptonMP) 060 202/' Two Sets of Structural Plans o 4+ .. 7. phone 413-587-1240' Fix�; „ ,, 2 Plot/Site Plans — 4' Nr�✓�Sp Tether Specify APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATOR-DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: JJ Q Map L3`� Lot O g/ Unit 117 Olander Dr - Unit 22, Northampton MA 011 Zone Overlay District Elm St.District CB District SECTION 2 -PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Mark Schlack 117 Olander Dr-Unit 22 Northampton MA 01060 Name(Print) Current Mailing Address: 413 570 4142 4PP AttarhmPnt A Telephone Signature 2.2 Authorized Agent: Pioneer Valley Photovoltaics 311 Wells St. Greenfield, MA 01301 Name(Print) J Current Mailing Address: C4A/u• 413-772-8788 Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 10439 (a)Building Permit Fee 2. Electrical 5351 1 (b)Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee `(/�1/_7 4. Mechanical (HVAC) 5. Fire Protection 6. Total= (1 +2 +3 +4+5) 63950 Check Number /a 7 00 /� This Section For Official Use Only Building Permit Number: 3�A/ � 4/y Date Issued: Signature: ' I /De/a 1 �• ! Building Commissioner/Inspector of Buildings Date buildingpermits @ pvsquared.coop EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding [O] Other[p] Brief Description of Proposed Workinstallation of 26 PV Panels on roof of residence. Installation of(2) solaredqe 9.8 kWh batteries, totaling 19.6kWh in basemei As this falls under 20kWh guidance, we will install per manufacterers specifications Alteration of existing bedroom Yes xx No Adding new bedroom Yes xx No Attached Narrative Renovating unfinished basement Yes xx No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves_ Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Mark Schlack , as Owner of the subject property PV Squared (Pioneer Valley Photovoltaics) hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. See Attachment A See Attachment A Signature of Owner Date PV Squared , as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Daniel Gomez Print Name 12/14/2021 Signature of Owner/Agent Date SECTION 8 -CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable E Name of License Holder: Daniel Gomez Gonzalez License Number 43 Hatfield St. Northampton, MA 01060 CS-111266 Address Expiration Date 03/14/2023 Signature Telephone / 413-772-8788 9. Registered Home Improvement Contractor: Not Applicable ❑ Pioneer Valley Photovoltaics Cooperative Company Name Registration Number 311 Wells Street, Suite B, Greenfield, MA, 01301 140077 Address Expiration Date 413-772-8788 Telephone 9/15/2023 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152, §25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ✓ No ❑