Loading...
23C-066 (8) BP-2021-2347 93 BLISS ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 23C-066-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2021-2347 PERMISSION IS HEREBY GRANTED TO: Project# SOLAR Contractor: License: NORTHEAST SOLAR DESIGN Est. Cost: 50748 ASSOCIATES LLC 106113 Const.Class: Exp.Date:06/07/2023 Use Group: Owner: CLOONEY DAVID & AMBER Lot Size (sq.ft.) Zoning: WSP Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC Applicant Address Phone: Insurance: 136 Elm St 4132476045 WC201900019843 HATFIELD, MA 01038 ISSUED ON:12/29/2021 TO PERFORM THE FOLLOWING WORK: 22 ROOF MOUNT SOLAR PANELS - 10KW BATTERY IN BASEMENT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough:, House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: • ".2 Qs- .; . iv . Fees Paid: $75.00 212Main Street, Phone(413) 587-1240,Fax:(413)587-1272 Office of the Building Commissioner ,M� �� C Orj I/ ir. -------,./1,— .17) - I oFC2 / Department use oily 8 2021 City'af Northampton Status of Permit Bui ding Department Curb Cut Driveway Permit r °rpr op.. 12 Main Street Seen-Septic Availability No�T 01NDIN =4,1 iNG/NSPCTI / Room 100 Vvater'WellAvailabiliy MA°r0s ONs Northampton, MA 01060 Two Seta of Structure Plans phon 31587.1240 Fax 413.587-1272 Piot'Sitb Plans Ober Speofy APPUCATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION y This section to be completed by office 1.1 emu= 93 Bliss St Map /`��-' Lot (2 Unit Florence MA 01062 tone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIPIAUTHORIZED AGENT 2.1 Owner of Record: 93 Bliss St t Amber Clooney Florence MA 01062 4 rre(Pnntl Curren;Miunr,ACdre5s. - Ctn' ,' 7elephore 413-345-9838 5o9ralure 2.2 Authorized Agent: Nort ---= t Sr I r 136 Elm St. Hatfield. MA 01038 Vane(Print) Curran;Malin,Andress' #‘111,z 413-247-6045 Signature A A* Tdnphurd . SECTION 3- - . TIO OST5 Item Estimated Coat(Dollars♦to be Official Use Only completed by permit applicant 1. Building (a f Bulldinp Permit Fee 2. Electrical (PI Estimated Total Cost of Construction trvrn f6) • 3. Plumbing Building Permit Fee 4. 141eohenical(HVAC) s.Fire Protector 6. Total ={l *2 *3*4 *5) $50.748 Check Number Ai 5Q0 This Section For OMlciai Use Only b s" d l- O�'`f 7 Date Building Permit Numer. ��fJ issued: Signature: i►1 i # 1 d-/ q/( .1 Elu/cln,Cpmmisb+oner;Ireepect r ryi HWdnr,c asta octopi S-DESCRIPTION Of PROPOSED WORK tcA.ck ill aDDlicablg) New House ❑ Addition ❑ Replacement Windows Alteration(s) Q Roofing [] Or Doors El Accessory Bldg. C3 Demolition ❑ New Signs (O] Decks IC Siding ID) Other(gig Brief Description of Proposed Install 22 solar panels on Roof& 10 kWh ESS Battery in basement Work: Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovabng unfinished basement Yea __No Plans Attached Roll -Sheet es.tr New house and or sddaritran to iodetino hceisirm complete the 1ollowhio: a. Use of building:One Farr ly Two Earrtily Other b. Number of rooms in each family unit: Number of Bathrooms c_ is there a garage attached? d. Proposed Square footage of new construction. Dimensions e_ Number of stories? f. Method of heating? Fireplaces or Weodstoves Number of each g. Energy Conservation Compliance_ Mas-acheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construcbon within 100 yr. floodplein Yes_____No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No_ I. Septic Tank City Sewer Private well_ City water Supply SECTDON Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1 Amber Clooney ,as Owner of the subject property hereby authorize Northeast Solar to act on my behalf.on II matters relative to work authorized by this building permit application. Si+ ..ure or caner 11 t�dtn 1. Gregory Garrison/Northeast Solar ,aa OwnadAuthohzed Agent hereby declare that the statements and information an the foregoing application are true and accurate,to the cost of my knowledge and belief_ Signed under the pains and penalties of perjury. Gregory Garrison Print hair* / '0 j g Sivature cr'arm-Mgt-'arm-Mg'arm-Mgt-re id,i SECTION 8-CONSTRUUCTION SERVICES 11 Licensed Construction Supervisor: Nat Applicable 0 Nee of LSunsa Holder. FY l l_p Ba�.tn s a�rd CS 10 6113 License Number 41 f-io_a_h Rd Co_ sin, Ma 4 c 6/7/23 'T = jJ =xpirstiun Oaf ------ ----- /'� ///C�/J 413-247-6045 �.Rialslond Hams imnovrasnt Contractor,tor, Not Applicable 0 Northeast Solar 169641 Campany.Name Registration Number 136 Elm. St . Hatfield, Na0103E 7/13/23 Address Expiration Data f 4 13-2 4 7-6 0 4 5 Telephone 4 • SECTION 10- s -K-tg •ENSATION*SURANCE AFFIDAVIT(M,O.L. c.1S2,$25C(6)) Workers Compensation Insurance affidavit must be completed and submitted Mth this application.Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes..._._.Xl No_...-, 0 11. -Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a License,provided that the owner acts 1O snoertisor.Cam 780. Sixth Edition Section 108.3.5.1, Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends co reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and or farm structures.A person who constructs more than one home In a two-rear period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that hef she shall be resoonsibllc for all such work performed under the bulldlne permit, As acting Comixoctimasperikex your presence an the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(1Vorkcrs'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you mutt be Liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsbilicy for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature _ City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facilitl S tyy, as defined by MGL c 111, S 150A. Address of the work: The debris will be transported by: PO ct' t w (p.uv The debris will be received by: ti('5 lG ( d "zr Building permit number: Name of Permit Applicant 0041/14064— }� �la pp : Date gnature of Permit Ap•�' nt The Commonwealth of Massachusetts Department of Industrial Accidents • _ lid?s N Office of Investigations 1 Congress Street, Suite 100 Boston, MA 02114-2017 •ja••.•0, -w ww.mass.gov/dia ww.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name:Northeast Solar Address:136 Elm St. City/State/Zip:Hatfield,Ma 01038 Phone#:413-247-6045 Are you an employer?Check the appropriate box: Business Type(required): 1. J❑ I am a employer with 17 employees(full and/ 5. ❑Retail or part-time).* 6. ❑Restaurant/Bar/EatingEstablishment 2.El I am a sole proprietor or partnership and have no 7. ❑Office and/or Sales(inch. real estate, auto, etc.) employees working for me in any capacity. [No workers' comp.insurance required] 8. ❑Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑Entertainment their right of exemption per c. 152,§1(4), and we have 10.0 Manufacturing no employees.[No workers'comp.insurance required]** 4.El We are anon-profit organization, staffed by volunteers, 11.0Healthcare with no employees. [No workers' comp. insurance req.] 12.0 Other *Any applicant that checks box#1 mist also fill out the sectionbelo v shoving their workers'compensation policy information. **If the corporate offices have exempted themselves,but the cceporation has other employees,aworkers compensation policy is required and such an organization should check box#1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance Company Name:New York Marine and General Insurance Company Insurer's Address: 93 Bliss St City/State/zip: Florence MA 01062 P olicy#or elf-ins.Lic.K #WC201900019843 pi 7/8/2022 Expiration Date: Attach a copy of the workers'comp ensatio n p olicy declaration page(showing the p olicy numb er and exp iratio n date). Failure to secure coverage as required under Section25A of MGL c. 152 can lead to the imposition of criminal penalties cf a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for ance coverage verification. Ido hereby cemfy, under . _ us • . • rperjwy that the information provided above is true and correct. Signature: Date: 10/18/2021 .44 Phone# 413-247-6045 '� Official use only. Do not wri . . A area, to be completed by city or town official City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.rnas s gov/dia NORTSOL-01 JHOGAN A4'-'CPR'O CERTIFICATE OF LIABILITY INSURANCE DATE D/YYYY) �� 7/9/2/9/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: EPIC Insurance Brokers&Consultants PHONE FAX (A/c,No,Ext):(781)455-0700 I puc,No):(781)449-8976 144 Gould Street Suite 100 Needham,MA 02494 n DD IIL55;certificates@robiininsurance.com INSURER(t)AFFORDING COVERAGE [ NAIC N INSURER A:Gotham Insurance Company INSURED i INSURER B:Safety Insurance Company 39454 Northeast Solar Design Associates,LLC I INSURER C:Capitol Indemnity Corporation 136 Elm Street INSURER D:New York Marine and General Insurance Company 16608 Hatfield,MA 01038 INSURER E: i INSURER F: COVERAGES CERTIFICATE NUMBER: • REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR i TYPE OF INSURANCE ADDL[SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD I WVD IMMJDD/YYYY) IMMIDDIYYYY) A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE S 1,000,000 CLAIMS-MADE X OCCUR 'PK201900018166 7/8/2021 7/8/2022 DAMAGETORENTED 300,000 PREMISES IEa occurrence) $ MED EXP(Any one person) S 5,000 PERSONAL 8 ADV INJURY S 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE S 2,000,000 POLICY X j LOC PRODUCTS-COMP/OP AGG S 2,000,000 OTHER: S 'COED B AUTOMOBILE LIABILITY (EaaMBIN acciden SINGLE LIMIT S 1,000,000 ANY AUTO 5909629 7/8/2021 7/8/2022 BODILY INJURY(Per person) S OWNED SCHEDULED AUTOSIRE� ONLY X AUTNOSSWN BODILY INJURY(Per accident) S X AUTOS ONLY X AUTOS ONLY PRarraccida DAMAGE S S C I X UMBRELLA(JAB ' X OCCUR EACH OCCURRENCE S 1,000,000 EXCESS LIAB I I CLAIMS-MADE 7/8/2021 7/8/2022 1,000,000 1 AGGREGATE S DED X RETENTIONS 10,000. S D WORKERS COMPENSATION X STATUTE OTH- AND EMPLOYERS'LIABILITYER Y/N WC201900019843 7/8/2021 7/ff/2022� 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L EACH ACCIDENT S OFFICER/MEMBER n BHR EXCLUDED? N N/A E.L.DISEASE-EA EMPLOYEE S 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT S A ,Property PK201900018166 7/8/2021 7/8/2022 BPP 225,000 A Property I PK201900018166 7/8/2021 7/8/2022 BI 350,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Issued as evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Cityof Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. 210 Main Street Northampton,MA 01060 AUTHORIZED REPRESENTATIVE IC'2ZL , , ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: LLC NORTHEAST SOLAR DESIGN ASSOCIATES, LLC Registration: 17 136 ELM ST Expiration: 07//13/1312023 HATFIELD,MA 01038 Update Address and Return Card. Office of Consumer Affairs ii Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:LLC before the exp ation date. If found return to: Registration Expiration Office of Co - mer Affai = and Business Regulation 169641 07/13/2023 1000 Washin) ).n Street 'Suite 710 NORTHEAST SOLAR DESIGN ASSOCIATES,LLC Boston,MA I 8 GREGORY GARRISON ,_ 136 ELM ST %xGl004 ■ HATFIELD,MA 01038 Undersecretary Not I • without signature Commonwealth of Massachusetts Division of Professional Licensure • Board of Building Regulations and Standards Conti -trpilt t rvisor CS-106113 fpires:06/07/2023 PHILUP BAUNSGARD;,J ' 41 HEATH ROAD 7-7COLRAIN MA741340 '•.,�a i • • Commissioner daeficR, t74+�c�ra. . . e ....f ^ '15•V,t,•%...4.-Akr,;7;'.•?tPt,3-.6,•-!..4:',-!-1`;'ilit.,•,1. ,-,, : ,„,,• - ••: ,. . . •, ..,,. Main electric P.';,'...C‘' • !.-' ",. , '40--:114--litay.;,:vitae_x andjultlity- '--, - „. - _ .i.;.,..e'i;-f...,!--14.'20:r ,:— v, ,--''-'7''''':' Ar• 'P- .• panel in • -,-_, "Pt-- - --- -A-N-4..-----•,V;z:l..,-*4.(*estlit.,;stilar AG=,-•-•_, r • I basement . "-* .--- .i -- tlo-t- rt- ,, ,, - , •--,- - • _ erior ext wail , : - • \ , , , -e.e.- ,.1„t---..,2! .-2!--, 0 -,it t . ._ ,. Roof mounted solar array with 21x LG modules and . 0 :.- -• 21x Enphase IQ7Plus-72-2-US .., . - • . mi•croinverters . 1 ....4 - it ,• . J. * ! • • .,A,, •- ., 44, 4." _4( . ' ..f" 1 .i. . t I- ' 46 "1, '-,; tV ' ". .4• V • . 1^ pi ':.1 ' • 4- '',i. ii. ,.. • . -, """44t, )il(-7 ..' , -' "..- • .•A••• if . ,. ..•• • , _ , 0 ‘ • -A.,-•t,rt_i AAA— ' '. • -. t ' I ' i..* "• * • "le-•R'll 4. ' i r'.-''L.': _ '...1.V ' ....•••‘:,•-. 1 i ' ' , ••.. "..s• k ., ,• ., • o s.i,11,7, f. , 4... lliti.. . ,c, • ; .,. . . . - i, ' • :"•4""' , 44r ;.,' "-.144kb' -_ .7' . - • • ..'•''' " :4'''. N. lif , ,44t: , ' ' 0-, ' •4r.,. 4.4 It 4.i ' 1.• . ..7.. •- ' 4,.",.\'-',, 'tl..."n .1114-.i.:•• .1", ,, . , • , '‘, , '' • ' .._ ' ob ‘ , i 4'. ' . ',,i,;,. ' '''''•..i ,s, '0"' , .e. • _ , .,, • . .- ) . ' ' r 4 ir 1 'lk,„,?'‘ ' .4 V\ :\ - . ; .. • ,,,t4.-. .i ''' 4 A . #:.*. ,0 ..„‘' , 1 .1, ' r • ", . .i.o:. • -.0 14 ' _ .' ,`".c, -,,k.O tt' *,;-•-,.. 9,'t-, ' N,4..„ „4,,•4,'i,":"f 4.4.,;t.'.4 "",".",. . L, , l . %„ •, -t.. .t•1ik t i'-t„-.. •'•",-,_•,..• .. . r ,. . 1 -•1 - t t - - _.. . ; . . _ k . ....,-: 4,,,7.FAI•ti ., e 1 ,,, ", - \le ' k ‘• t. —",k 4 - . \ \,..-f, -,..- ' , • .7 , . .. ,. . . - - - . . . _. . •,-- ,,,,' . Amber Clooney 93 Bliss St 4 Florence, Ma 01062 ... . Northeast Solar Vreeland Design Associates An integrative approach to design engineering and site planning Date: December 23, 2021 To: Justin Annis NorthEast Solar 136 Elm Street Hatfield, MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: Amber Clooney, 93 Bliss St, Florence, MA: Structural assessment of existing house roofs to support proposed solar arrays. I have investigated the existing main house roof framing for the proposed PV solar panel installations. The original 22'x 26', 1-3/4-story stone faced house was constructed around 1850. A 14'x 12', 2-story ell addition has been constructed off the west side of the main house starting at the north gable end at a later date. 12 PV solar panels are to be installed on the east facing roof of the main house, 4 solar panels on the west facing roof and 5 solar panels on the south facing roof of the ell addition. The main house rafters are full dimension 2x5+ installed 24"±on-center, spanning 10' with a pitch of 9/12. The rafters appear to be supported on balloon framed full dimension 2x4 walls with the top of the walls approximately 4' above the floor. 2x5 ceiling joists are attached to the sides of the rafters approximately 3' above the top of the walls and help along with the balloon framed walls to prevent the roof from spreading. The ell addition roof is framed with full dimension 2x5 rafters installed 18"-24"on-center, spanning 6'-8"with an 8/12 roof pitch. 2x5 ceiling joists are attached to the bottom of the rafters preventing the roof from spreading. The old roofing has been removed with %"plywood installed over the original 1" roof boards, Standing-seam metal roofing,the seams at 16" on-center, has been installed on the plywood. Snow guards have been installed along the roof eaves. I have reviewed the mounting details for the proposed array. Based on my calculations and a PV solar panel unit weight of 40± lbs, with the attachment points of the array placed at a maximum of 32"on center(every other standing seam)and staggered to minimize the load to any one rafter, the existing roof framing of the main house and ell addition are adequate to support the proposed PV solar arrays and the snow and wind load requirements of the current MA State Building Code. Please contact me if you have any questions or need additional information. Sincerely, (6kDF Mgssgc DAVID A. y VREELAND ^, cte. 9CIVIL No. 46317 "' David Vreeland, PE ,-Po ,�.G p �, Vreeland Design Associates 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 LGNON®R LG400Q 1 C-A6 400W LG NeON®R is powerful solar module that provides world-class performance.A new cell structure that eliminates electrodes on the front maximizes the utilization of light and enhances reliability. - - LG NeON®R is a result of LG's efforts to increase customer's values beyond efficiency.LG NeON®R features enhanced durability, performance under real-world conditions,an enhanced warranty and aesthetic design suitable for roofs. .4. 25, C ® US YEAR PRODUCT•PERFORMANCE•LABOR WARRANTY • • Features Roof Aesthetics ® 25-Year Limited Product Warranty LG NeON®R has been designed with "' The NeON®R is covered by a 25-year limited aesthetics in mind:the lack of any product warranty.In addition,up to$450 of electrodes on the front creates an labor costs will be covered in the rare case that improved,modern aesthetic. a module needs to be repaired or replaced. Enhanced Performance Warranty More generation per square meter The LG NeON®R has an enhanced The LG NeON®R has been designed to performance warranty.After 25 years, significantly enhance its output,making LG NeON®R is guaranteed at least it efficient even in limited space. 92.5%of initial performance. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA,Inc. �� LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar energy source research program in 1985,supported by LG Group's vast eopenence in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoX•series to the market,which is now available in 32 countries.The NeON.(previous MonoX•NeON),NeONS2,NeON'2 BiFacial won the"Intersolar Life 5 Good AWARD'in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. LG NeON'R LG400Q1 C-A6 General Data Electrical Properties(STC*) Cell Properties(Material/Type) Monocrystalline/N-type Model LG40001C-A6 - • Cell Maker LG Maximum Power(Pmax) [W] 400 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [V] 37.2 Module Dimensions(L x W x H) 1,740mm x 1,042mm x 40mm MPP Current(Impp) [A] 10.76 Weight --_- - 18.5 kg -_-- Open Circuit Voltage(Voc,t5%) [V] 43.8 Glass(Material) Tempered Glass with AR Coating Short Circuit Current(Isc,t5%) [A] 11.32 Backsheet(Color) White Module Efficiency [%] 22.1 Frame(Matenal) Anodized Aluminium Power Tolerance [%] 0-.3 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes `STC(Standard Test Condition).Irradiance 1000 Wm',Cell temperature 25'C,AM 1.5 Cables(Length) 1,250mm a 2EA Measure Tolerance.±3% Connector(Type/Maker) MC 4/MC Operating Conditions Certifications and Warranty Operating Temperatu a [°c] 40-+85 - Maxmum System Voltage [V] 1,000 !EC 61215-1/-1-1/2:2016,IEC 61730-1/2:2016, -- UL 61730-1:2017,UL 61730-2:2017 Maximum Series Fuse Rating [A] 20 Certifications' ISO 9001,ISO 14001,ISO 50001 Mechanical Test Load'(Front) [Pa/psf] 5,400 OHSAS 18001 MechanicalTest Load'(Rear) [Pa/psfl 4,000 Salt Mist Corrosion Test IEC 61701:2012 Severity 6 'The operating ambient temperature of these devices may exceed 40'C at full load for all wire sizes if is determined suitable in the field use application. Ammonia Corrosion Test IEC 62716:2013 **Based on IEC 61215-2:2016(Test Load-Design Load x Safety Factor(1 5)) Module Fire Performance Type 1(UL 61730) Fire Rating Class C(UL 790,ULC/ORD C 1703) Solar Module Product Warranty 25 Years Packaging Configuration Solar Module Output Warranty Linear Warranty* Number of Modules per Pallet [EA 25 "Improved 1" 985%,from2-24th -025 Number of Modules per40'Container [EA] 650 year year %/year down,92.5%at year 25 Number of Modules per 53'Container [EA] 850 Packaging Bon Dimensions(L x W x H) (mm] 1,790 a 1,120 x 1,227 Temperature Characteristics Packaging Box Dimensions(L x W x H) [in] 70.5 x 44.1 x 48.3 NMOT ['C] 44-r 3 --- -.- Packaging Box Gross Weight [kg] 498 Pima [%PC] -0.29 __ - Packaging Box Gross Weight [lb] 1,098 Voc [%PC] -0,24 Pic [%PC] 0.04 *NMOT(Nominal Module Operating Temperature):Irradiance 800 W/m',Ambient temperature 20'C, Dimensions(mm/inch) Wind speed 1 m/s,Spectrum AM 1.5 1042 0/41 0(Steep(Short Side) Electrical Properties(NMOT) Model LG400Q1C-A6 1002.0/39A(Distance Inferno GroindingaMorxruq ) a. Maximum Power(Pmax) [W] 303 600/,57 MPP Voltage(Vmpp) [V] 35.2 16-8.0x 3.0/0.3x0.1 1 Drain Hales MPP Currem(Impp) [A] 8.62 (-) I*) t --. _ B-04.3/0.2 o Open circuit voltage Na) [V] Grounding Holes -(unction Box Short Circuit Current(Isc) [A] --- 9.13 8-8.5x120/03x0.5 •--1 Mouxag Holes I-V Curves 12500/49.2 F Came Length 1 2.0 1000 W I I 10.0- 800W 600 W el el g 400W I 4.0- 200W • 2.0- \ . .- 0.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 0 AAUP m1 � `� - • • � LG Electronics USA,Inc. Product specifications are subject to change without notice. • Solar Business Division LG40001C-A6.pdf L" LG 2000 Millbrook Drive 011821 Lincolnshire,IL 60069 Life's Good www.lg-solarcom 0 2021 LG Electronics USA,Inc.All rights reserved. • CCE i G rr;> In The Right Way! " 2 0 as 3-5-U Ciamp p I The S-5-U clamp is by far our most LC) I popular and most versatile clamp. It fits about 85%of the standing seam profiles manufactured in North America—including most structural and 3 ,„ v-- 4 architectural profiles. It can be used on 0 vertically oriented seams and, by rotating Othe clamp 90 degrees, it can also be used _ *� O on most horizontal 2" seam profiles. L Its simple design, generous dimensioning, _. co and multiple hole orientations are what ,111.11111111111 make the S-5-U clamp so versatile for use CD Ewith the S-5!`" snow retention products, such as ColorGard", as well as with other iiik O heavy-duty applications. 0) Installation is as simple as setting the C specially patented round-point setscrews I. t into the clamp, placing the clamp on t\ 11 '*-' the seam, and tightening them to the cspecified tension.Then,affix ancillary co items using the bolt provided with the E 4-+ product. Go to www.S-5.com/tools 0 O for information and tools available for () Eproperly attaching and tensioning S-5! LO clamps. ca Cl) . S-b-U Mini C amr asThe S-5-U Mini is a bit shorter than the 5-5-U and has one setscrew rather than 4-6 CU two.The mini is the choice for attaching O all kinds of rooftop accessories: signs, The S-5-U clamp is N walkways, satellite dishes,antennas, M rooftop lighting, lightning protection our most popular andgzt clasystems, solar arrays, exhaust stack versatile clamp, fitting M bracing,conduit,condensate lines, LO .= mechanical equipment—just about about 85% of the N ,a) anything!* standing seam profiles co i CO S-5!mini clamps are not compatible with,and should not in North America. co 1rz'z be used with 5-5!SnoRail"/SnoFence—or ColorGard"snow CO retention systems. s_5! k The strength of the S-5-U clamp is in its simple design. The patented setscrews will slightly dimple the metal seam material but not pierce it— leaving the roof manufacturer's warranty intact. The Right Way!' The S-5-U and 5-5-U Mini clamps are each furnished with S-5-U C I a Cn p the hardware shown to the right.Each box also includes a bit tip for tightening setscrews using an electric screw gun.A structural aluminum attachment clamp,the S-S-U is compatible with most common metal roofing materials excluding copper.All included hardware is stainless \ steel.Please visit www.S-5.com for more information „j including CAD details,metallurgical compatibilities and =y, specifications. , � //) The S-5-U clamp has been tested for load-to-failure results $A - / on most major brands and profiles of standing seam o R /`/I roofing. The independent lab test data found at J y j , www.S-5.com can be used for load-critical designs and ` applications.S-5!®holding strength is unmatched in the lids ,,'industry. o S. Example Profiles ti. Note:Install both 4) setscrews on same side of clamp. I S-5-U Mini Clamp I III a 1 For horizontal seams under 0.65",do not use this clamp.Visit figQ'4n ' ... d www.S-5.com for more detailed information and proper clamp usage. fi3 /h 7-- Please note:All measurements are rounded to the second decimal place. S-5!"Warning!Please use this product responsibly! Distributed by Products are protected by multiple U.S.and foreign patents.Visit the website at www.S-5.com for complete information on patents and trademarks.For maximum holding strength,setscrews should be tensioned and re-tensioned as the seam material compresses.Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel.Consult the 5-51 website at www.S-5.com for published data regarding holding strength. Copyright 2020,Metal Roof Innovations,Ltd.S-51 products are patent protected. 5-5!aggressively protects its patents,trademarks,and copyrights.Version 050721. Tech Brief IRONRIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless / / I extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of -.- ripping panels from a roof, and snowfalls weighing '`� \ enough to buckle a panel frame. \,� XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently ; ,, transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof penetrations and the amount 4 ,( of installation time. 1 1 / 41.01K., I`,„ , Q°. r, ._ Force-Stabilizing Curve Sloped roofs generate both vertical and lateral _..-- forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat&Pitched Roofs • Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000-series compatible with �� a range of tilt legaluminum alloy,then protected with an I- otherpool and r-1 options for flatanodized finish.Anodizing prevents surface 1other pitched roof ( l 1 roof mounting and structural corrosion,while also providing attachments. applications. a more attractive appearance. Ilthill' XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. ii____ ,.........,..... ,....................... XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:AS",,,CE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF) Wind(MPH) 5'4" 6' 8' 10' 12' 90 120 None 140 1 XR10 160 • 90 120 20 , 140 160 90 30 160 90 40 *, 160 80 160 120 160 • `Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. ©2020 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.20 'AMMO 5/8" Type X gypsum mounted to floor joist extending 24" past perimeter of battery footprint. i Qty. 1 @ Enphase Encharge 10 Battery mounted on wall Basement has varying types of poured concrete, stone with mortar, and brick walls Note: A 2x4" stud wall for component mounting may be installed with 5/8" Type X gypsum extending 24" past perimeter of battery Data Sheet En phase Storage System Enphase The Enphase Encharge 10TM all-in-one AC-coupled storage system is reliable,smart,simple,and safe. It is Encharge 10 comprised of three base Encharge 3TM storage units,has a total usable energy capacity of 10.08 kWh and twelve embedded grid-forming microinverters with 3.84 kW power rating. It provides backup capability and installers can quickly design the right system size to meet the needs of both new and retrofit solar customers. Reliable • Proven high reliability IQ Series Microinverters • Ten-year limited warranty • Three independent Encharge storage base units ENPHASE • Twelve embedded IQ 8X BAT Microinverters • Passive cooling(no moving parts/fans) kaa Smart d y, k , • Grid-forming capability for backup operation • Remote software and firmware upgrade , 4 • Mobile app-based monitoring and control k '4 • Support for self consumption • Utility time of use(TOU)optimization 2 Simple • Fully integrated AC battery system • Quick and easy plug-and-play installation • Interconnects with standard household AC wiring Safe • Cells safety tested • Lithium iron phosphate(LFP)chemistry for maximum safety and longevity ENPHASE P H AS E To learn more about Enphase offerings,visit enphase.com u Enphase Encharge 10 MODEL NUMBER ENCHARGE-10-1P-NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery management unit(BMU).Includes: -Three Encharge 3.36 kWh base units(B3-A01-US001-1-3) -One Encharge 10 cover kit with cover,wall mounting bracket,watertight conduit hubs,and interconnect kit for wiring between batteries(B10-C-1050-0) ACCESSORIES ENCHARGE-HNDL-R1 One set of Encharge base unit installation handles OUTPUT(AC) @ 240 VAC' Rated(continuous)output power2 3.84 kVA Peak output power 5.7 kVA(10 seconds) Nominal voltage/range 240/211 —264 VAC Nominal frequency/range 60/57—61 Hz Rated output current 16 A Peak output current 24.6A(10 seconds) Power factor(adjustable) 0.85 leading...0.85 lagging Maximum units per 20 A branch circuit 1 unit(single phase) Interconnection Single-phase Maximum AC short circuit fault current over 3 cycles 69.6 Arms Round trip efficiency2 89% BATTERY Total capacity 10.5 kWh Usable capacity 10.08 kWh Round trip efficiency 96% Nominal DC voltage 67.2 V Maximum DC voltage 73.5 V Ambient operating temperature range -15°C to 55°C(5°F to 131°F)non-condensing Optimum operating temperature range 0°C to 30°C(32°F to 86°F) Chemistry Lithium iron phosphate(LFP) MECHANICAL DATA Dimensions(WxHxD) 1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) Weight Three individual 44.2 kg(97.4 Ibs)base units plus 21.1 kg(48.7 Ibs)cover and mounting bracket;total 154.7 kg(341 Ibs) Enclosure Outdoor—NEMA type 3R IQ 8X-BAT microinverter enclosure NEMA type 6 Cooling Natural convection—No fans Altitude Up to 2500 meters(8200 feet) Mounting Wall mount FEATURES AND COMPLIANCE Compatibility Compatible with grid-tied PV systems.Compatible with Enphase IQ Series Micros,Enphase Enpower,and Enphase IQ Envoy for backup operation. Communication Wireless 2.4 GHz Services Backup,self-consumption,TOU,Demand Charge,NEM Integrity Monitoring Enlighten Manager and MyEnlighten monitoring options;API integration Compliance UL 9540,UN 38.3,UL 9540A,UL 1998,UL 991,NEMA Type 3R,AC156 EMI:47 CFR,Part 15,Class B,ICES 003 Cell Module:UL 1973,UN 38.3 Inverters:UL 62109-1,IEC 62109-2,UL 1741SA,CAN/CSA C22.2 No.107.1-16,IEEE 1547 LIMITED WARRANTY Limited Warranty' >70%capacity,up to 10 years or 4000 cycles 1.Supported in backup/off grid operations 2.AC to Battery to AC at 50%power rating. 3.Whichever occurs first.Restrictions apply. To learn more about Enphase offerings,visit enphase.com ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Encharge 10,and other trademarks or service names are the trademarks E N P H A S E of Enphase Energy,Inc.Data subject to change.2020-11-23 `/