Loading...
36-384 (2) SM-2021-0071 214EMERSON WAY COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 36-384-001 CITY OF NORTHAMPTON Permit: Sheet Metal PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# SM-2021-0071 PERMISSIONIS HEREBY GRANTED TO: Project# SHEET METAL Contractor: License: SOVEREIGN BUILDERS INC ROCK Est. Cost: 26000 VALLEY HVAC Const.Class: Exp.Date: Use Group: Owner: BERKENWALD, AARON &BIANCA Lot Size (sq.ft.) Zoning: SR Applicant: ROCK VALLEY HVAC Applicant Address Phone: Insurance: 296CNONOTUCK STREET 4135357804 FLORENCE, MA 01062 ISSUED ON:11/22/2021 TO PERFORM THE FOLLOWING WORK: HVAC FOR NEW HOUSE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: imid,646.k., .>2 Fees Paid: $50.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner Commonwealth of Massachusetts R A •tal Permit Date: 11/10/2021 'VE 'ermi # S/1/ 7/ Estimated Job Cost: $26,001.00 1 'e t Fee: $ '. NOV 5 2021 � Lp Plans Submitted: YES NO; Lo,au1CO�NG iNSPEcrioN$lan Reviewed: YES NO NOR7HAMProN,MA 01060 Business License# 824 : i s icant License# Business Information: Property Owner/Job Location Information: Name: Jesse Fortier(Rock Valley HVAC) Name: Sovereign Builders Street: 296C Nonotuck Street Street: 214 Emerson Way City/Town: Florence City/Town: Northampton Telephone: (413) 535-7804 Telephone: (413) 527-8001 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft.A1 over 10,000 sq. ft. Number of Stories:2 Sheet metal work to be completed: New Work: Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide and install American Standard 20-SEER ducted heat pump system. Fabricate and install custom sheet metal duct system, ductwork to be sized according to Manual J 8tn edition heat load calculation. Ductwork to be sealed with Aeroseal technology, duct leakage to be sealed below 5 sq. in of leakage. Attic ductwork to be wrapped with R8 insulation, basement ductwork to be wrapped with R6 insulation. INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes MNo 0 If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy • Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner • Agent ❑ Signature of Owner or Owner's Agent By checking this box.,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progress Inspections Date Comments Final Inspection Date Comments Type of License: By Master Title ❑ Master-Restricted City/Town ❑ Journeyperson Signature of Licensee Permit# _ ❑ Journeyperson-Restricted AA �/b�� License Number: „l Fee$_ ❑ Check at www.mass.qov/dpl •n tti\f ;t4,4 1/4g, nspector Signature of Permi g&proval Pro ect Job: -� Summa wrightsoft � � Date: 11/4/2021 Entire House By: Rock Valley HVAC Inc. 296C Nonotuck Street,Florence,Ma 01062 Phone:(413)535-7804 Email:RockValleyHVAC@yahoo.com Web:wwwRockValleyHVAC com License:SM2626 Pro'ect Information For: Sovereign Builders 214 Emerson Way,Northampton,Ma 01062 Phone:(413)527-8001 Notes: Desi•n Information Weather: Greenfield(Worcester Dd),MA,US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 °F Daily range M Relative humidity 50 % Moisture difference 42 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 33862 Btuh Structure 15115 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfrn) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33862 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 13603 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 612 Btuh Ducts 0 Btuh Central vent(0 cfrn) 0 Btuh Heating Cooling (none) Area(ft') 2429 2429 Equipment latent load 612 Btuh Volume(ft') 21861 21861 Airchanges/hour 0.11 0.06 Equipment Total Load(Sen+Lat) 14215 Btuh Equiv.AVF(cfrn) 40 22 Req.total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make American Standard Make American Standard Trade AMERICAN STANDARD Trade AMERICAN STANDARD Model 4A6V0036A1 Cond 4A6V0036A1 AHRI ref 10093447 Coil TAM9A0B30V31 AHRI ref 10093447 Efficiency 10 HSPF Efficiency 13.0 EER,20 SEER Heating input Sensible cooling 24780 Btuh Heating output 32600 Btuh @ 47°F Latent cooling 10620 Btuh Temperature rise 25 °F Total cooling 35400 Btuh Actual airflow 1180 cfrn Actual airflow 1180 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.078 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.96 Capacity balance point=5°F Backup:American Standard Input=8 kW, Output=27297 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft'" 2021-Nov-10 12:16:29 _ Right-Sute®Uriversal 2021 21.0.07 RSU24598 Page 1 ACCA ...Jobs\Sovereign 214 Emerson\214 Emerson Way.rup Calc=MJ8 Front Door faces: N N Level I r J _" T .11. 1 at Roo r ba50A§.4 , E. <----... • Garage Pa ry $ (__ COhSe- -0 AReel Ft r P iMubom STR Foyer A CL AIN p Lap aifJ i (N ba_L( --ypkkit .........- ri isms Sytk k • ) / 11,40 h 5 Nei Viic I le\ ( ba. etv'kul-1 Job#: Rock Valley HVAC Inc. Scale:l :108 Performed for: Page 2 Sovereign Builders 296C Nonotud<Street Right-Suite®Universal 2021 214 Emerson Way Florence,Ma 01062 21.0.07 RSU24598 Northampton,Ma 01062 Phone:(413)535-7804 2021-Nov-10 12:16:21 Phone:(413)527-8001 www.RodcValleyHVAC.com RockValleyHVAC@yahoo.00m 214 Emerson\214 Emerson Way rup N .47 2nd Floor I1_,._ --�.._ 4 I M WIC Office T Bed Btl 2 -; CL3 t , , aVI rillialligiLe ball I C Of E---c�ds.e_ .(19( 5 �' Y Lu ry ' r -ci 4-o .� t C. Master STR2 t Oa( 4 feed.reed"(o Bath A 12 6/e • I ( A Bath i MP 11\R lk, Alp .. le___,C...\--cL( k- 5o_OL -f-r ittn5 cn ifi4i L Job#: Rock Valley HVAC Inc. Scale.1 :108 Performed for: Page 1 Sovereign Builders 296C Nonotudc Street RightSuite®Universal 2021 214 Emerson Way Florence,Ma 01062 21.0.07 RSU24598 Northampton,Ma 01062 Phone:(413)535-7804 2021-Nov-10 12.16:20 Phone:(413)527-8001 www.RockValleyHVAC.com Rock\alleyHVAC@yahoo.com 214 Emerson\214 Emerson Way.rup Eligible for Federal Tax Credit . ...1 CERTIFIED www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 10093447 Date: 11-10-2021 Model Status:Active AHRI Type: HRCU-A-CB(Split System: Heat Pump with Remote Outdoor Unit-Air-Source) Series:PLATINUM ZV Outdoor Unit Brand Name:AMERICAN STANDARD Outdoor Unit Model Number (Condenser or Single Package):4A6V0036A1 Indoor Unit Model Number(Evaporator and/or Air Handler):TAM9AOB30V31 The manufacturer of this AMERICAN STANDARD product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F), btuh :35400 SEER:20.00 EER(A2)-Single or High Stage(95F): 13.00 Heating Capacity(H12)-Single or High Stage(47F):32600 HSPF(Region IV): 10.00 t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on`Verify Certificate"link we make life better' and enter the AHRI Certified Reference Number and the date on which the certificate was issued. which is listed above,and the Certificate No.,which Is listed at bottom right. ©2021 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132810393286028487