Cohen- Planset (Full)RELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVINGJURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNAdvancedSolarSolutions39650MallardBassLake,CA93604 PHONE: 559-321-7000EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSEDWRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING BLOCKS RSD DEVICE BATTERY UNIT SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLEALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDEDAND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJREQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT ROOF COVERING NORTH ⅊⅊ ⅊ ⅊ DRIVEWAY WARD AVE N/A VB 7.600 KW PV-001 COVER SHEET Cohen, Michael Jake Stocker 2015 National Grid 2015 05013881 2015 21134A(413) 584-8844 2020 Lilian Wanjiku(413) 584-8844 City of Northampton jstocker@valleysolar.solar R-3 II Exposure C 40 (413) 584-8844jstocker@valleysolar.solar Cohen, Michael44 Ward Ave, Northampton, MA 01060 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/ BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 Q-Cells Q.Peak BLK G9 380Enphase IQ7PLUS-72-2-US (240V) EcolibriumSolar EcoFoot 2+ Ballast Blocks INTEGRATED IN INV Enphase Encharge-10 & Encharge-3 2020 N/A 82 N/A 2 1 (E) GPS COORDINATES:(42.31881574710984, -72.65245405878163) 5.900 KW 2 120/240V - 1 10° 175° MAX ARRAY HGT 117 N/A MEMBRANE N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION E-001 EQUIP. CALCULATION METER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS Enphase X-IQ-AM1-240-3-ES 400A BUS/400A MAIN BREAKER BACK-FED BREAKER PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS GENERALNOTES:* PROPERACCESSANDWORKINGCLEARANCEAROUND EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE PROVIDEDASPERSECTIONNEC110.26. PVSYSTEMCOMPONENTS;INCLUDINGBUTNOTLIMITED TO,MODULES,INVERTERSANDSOURCECIRCUIT COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV SYSTEMSINCOMPLIANCEWITHNEC690.4AND690.6 ANDALLUL,IEC,IEEECLASSIFICATIONSAS REQUIREMENTS. RAPIDSHUTDOWNNOTES:* PVSYSTEMCIRCUITSINSTALLEDONORINBUILDIDNG SHALLINCLUDEARAPIDSHUTDOWNFUNCTIONTHAT CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE WITH2020NEC690.12(A)-(D) EQUIPMENTLOCATIONS&ELECTRICAL NOTES:* JUNCTIONANDPULLBOXESAREPERMITTEDTOBE INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH NEC690.34. ADDITIONALACDISCONNECT(S)SHALLBEPROVIDED WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SERVICINGDISCONNECT.2020NEC690.15(A) ALLEQUIPMENTSHALLBEINSTALLEDACCESSIBLETO QUALIFIEDPERSONNELINCOMPLIANCEWITHNEC APPLICABLECODES. ALLCOMPONENTSARELISTEDFORTHEIRINTENDED PURPOSEANDRATEDFOROUTDOORUSAGEWHEN APPLICABLE. STRUCTURALANDINSTALLATION NOTES:* RACKINGSYSTEM&PVPANELSMOUNTEDONA ROOFTOPSHALLBELISTEDANDLABELEDINACCORDANCE WITHUL1703ANDSHALLBEINSTALLEDINACCORDANCE WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED THEPRE-ENGINEEREDMAXSPANSOUTLINEDBYTHE RACKINGMANUFACTURESENGINEEROFRECORD. GROUNDINGNOTES:* INUNGROUNDEDSYSTEMSONLYTHEDCCONDUCTORS AREUNGROUNDEDANDREQUIREANEQUIPMENT GROUNDINGCONDUCTOR.ALLMETALELECTRICAL EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUND,INCOMPLIANCEWITHNEC250.134ANDNEC 250.136(A). PVEQUIPMENTINCLUDINGMODULEFRAMESANDOTHER METALPARTSSHALLBEGROUNDEDINCOMPLIANCE WITHNEC690.43ANDMINIMUMGROUND CONDUCTORSSIZEDINACCORDANCEWITHNECTABLE 250.122. CONDUCTIVEPARTSOFMODULEFRAMES,MODULE RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN COMPLIANCEWITHNEC250.134ANDNEC250.136(A). UL2703APPROVEDMODULEANDRACKGROUNDING SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S INSTALLATIONMANUAL.IFUL2703APPROVED GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG HOLESPERTHEMANUFACTURER'SINSTALLATION REQUIREMENTS. THEGROUNDINGCONNECTIONTOAMODULESHALLBE ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER MODULE. THEGROUNDINGELECTRODESYSTEMCOMPLIESWITH NEC690.47ANDNEC250.50THROUGHNEC250.106. IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN COMPLIANCEWITHNEC250,NEC690.47ANDAHJ. PVSYSTEMSSHALLBEPROVIDEDWITHDCGROUND- FAULTPROTECTION2020NEC690.41(B) INTERCONNECTION/POCNOTES:* ALLLOAD-SIDEINTERCONNECTIONSAREINCOMPLIANCE WITH2020NEC705.12(B) THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN COMPLIANCEWITHNEC705.12(B)(2)(3)(c) ALLFEEDERTAP(LOADSIDE)INTERCONNECTIONSAREIN COMPLIANCEWITH2020NEC705.12(B)(2)(1) THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL ALSOBESIZEDAPPROPRIATELYASPER2020NEC 705.12(B)(2)(3)(b) SUPPLYSIDETAPINTERCONNECTIONSAREIN COMPLIANCEWITHNEC705.12(A)WITHSERVICE ENTRANCECONDUCTORSINCOMPLIANCEWITHNEC 230.42 BACKFEEDINGBREAKERFORINVERTEROUTPUTISEXEMPT FROMADDITIONALFASTENING2020NEC705.12(B)(5) MICROINVERTERBRANCHCIRCUITSSHALLBECONNECTED TOASINGLEOCPDINACCORDANCEWITHTHEIR INSTALLATIONINSTRUCTIONSANDNEC690.9 DISCONNECTSANDOCPDNOTES:* ALLDISCONNECTINGSWITCHESWILLBECONFIGUREDSO THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” (TYPICALLYTHEUPPERTERMINALS) ALLACDISCONNECTSSHALLBELABELED,LOCKABLE,OF VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. ACDISCONNECTSSHALLBEA“KNIFEBLADE”TYPE DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER PERNEC110.28 ADDITIONALACDISCONNECTSSHALLBEPROVIDED WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC DISCONNECT.2020NEC690.15(A) BOTHPOSITIVEANDNEGATIVEPVCONDUCTORSREMAIN UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH 2020NEC690.15(D) ALLOCPDRATINGSANDTYPESSPECIFIEDSHALLBEIN COMPLIANCEWITHNEC690.8,690.9,705.12AND240. BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE UNGROUNDED;BOTHREQUIREOVERCURRENT PROTECTIONINCOMPLIANCEWITHNEC690.9 ARCFAULT(AFCI)DCCIRCUITPROTECTIONISREQUIRED FORALLPVSYSTEMSONORPENETRATINGABUILDING WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR GREATER.ALLDCPVCIRCUITSINSTALLEDINORON BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN COMPLIANCEWITHNEC690.11,UL1699BANDSHALLBE LISTEDANDLABELEDINACCORDANCEWITHUL1699(B). WIRING&CONDUITNOTES:* ALLCONDUITANDCONDUCTORSSHALLBEAPPROVED FORTHEIRINTENDEDPURPOSEINCLUDINGWET LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE MINIMUMCODEREQUIREMENTSANDARENOTLIMITED TOUPSIZING. ALLCONDUCTORSSHALLBESIZEDINCOMPLIANCEWITH NEC690.8,NEC690.7. ALLCONDUCTORSSHALLBEDERATEDASAPPLICABLETO THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT SUNLIGHTINACCORDANCEWITH2020NEC 310.15(B)(3)(4)(c) EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT CIRCUITSSHALLUSECONDUCTORSLISTEDANDIDENTIFIED ASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE2020NEC 690.31(C)(1).PVMODULESWIRELEADSSHALLBELISTED FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE WITH2020NEC690.4(B) PVWIREBLACKWIREMAYBEFIELD-MARKEDWHITEIN COMPLIANCEWITHNEC200.6(A)(6). PVMODULECONDUCTORSLOCATEDUNDERARRAYSWILL BESECUREDINAWORKMANLIKEMANNERIN COMPLIANCEWITHNEC110.12. WATERPROOFING:* ALLNEWROOFTOPPENETRATIONSSHALLBESEALEDAND MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SEALANTANDFLASHINGSWHEREREQUIREDPERCODE ANDGENERALBUILDINGANDROOFINGWORKMANSHIP STANDARDSBYALICENSEDCONTRACTOR. ALLEXTERIORELECTRICALEQUIPMENT,SHALLBENEMA 3RORBETTERRATED.ALLEXTERIORCONDUITAND CONNECTORSSHALLBERATEDFORWETLOCATIONS. *ALLNOTESAREASAPPLICABLETOTHISPROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS PROJECT.N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPN2015 IFC ROOF ACCESS REQUIREMENTS PV SITE LAYOUT LEGEND * EXISTING DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 NORTH SECTION 1 RA RA SECTION 2 VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 LOCATED ON SHEET E-100. A. B. C. THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOTBE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALEAND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 3/32” = 1’0” @ SHEET SIZE A3 3021 SECTION-1 367 13.51% 175 1.2°SECTION-1 175 1.2°SECTION-2 41SECTION-2 QTY 20 Q-Cells Q.Peak BLK G9 380 MODULES, QTY 20 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESS* EXISTING ROOF DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFING COVERING RACKING MAX PSF ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO NORTH 1 1 1 1 1 1 1 1 2 2 2 2 2 2 22 2 2 2 2 2 2 2 2 2 2 2 2 2 2 63 3 3 3 3 3 3 3 32'-10"18'-2"3'-4"12'-1" ￿ ￿￿￿ ￿ BYTHEBALLASTEDMOUNTINGMANUFACTURER. BAYLOCATIONS,QUANTITYOFBALLASTBLOCKSINEACHBAY,AVERAGEANDMAXIMUMPOUNDSPERSQUAREFOOT,ROOFANCHORLOCATIONSIFREQUIREDSHALLBEDETERMINEDANDVERIFIEDBYALLMANUFACTURERGUIDELINESANDRECOMMENDATIONSASWELLASSTRUCTURALENGINEERING C.ANYROOFANCHORATTACHMENTPOINTSIDENTIFIEDASNECESSARYBYTHEMANUFACTURERORSTRUCTURALSHALLBEINSTALLEDINACCORDANCEROOFANCHORMANUFACTURESDETAILEDINSTRUCTIONS. SECTION 1 PVARRAYTAGSECTION#MODULEGROUP ROOFATTACHMENTPOINT BALLASTRACKINGSYSTEMW/BLOCKNUMBER # PVMODULE PVRACKINGLEGEND A.ROOFSLOPESSHALLNOTEXCEEDTHEMAXIMUMRECOMMENDED B.BALLASTEDRACKINGCONFIGURATIONINCLUDINGBALLASTBLOCK ENGINEERINGWITHTHEBALLASTANDTHE SCALE: 3/32” = 1’0” @ SHEET SIZE A3 Flat Roof With Trusses 16" O.C. Steel Trusses @ 16" MAX OC MEMBRANE 2.72 PSF QTY 20 Q-Cells Q.Peak BLK G9 380 MODULES, QTY 20 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER S-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND 21SCALE: NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODEREQUIREMENTS AT THE TIME IT WAS BUILT. C.STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING ISACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARYCONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL BE NO MORETHAN TWO LAYERS.(SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ONPLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUTSIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURALDETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I.AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES.STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSPER RAIL MANUFACTURER L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILSARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL D2 (E)WALL D2 D2 BALLASTBLOCKS 9.61".7 64.5 LBracket,2”x3” Bolt,Carriage3/8”x1” Nut,SerratedFlangeHex,3/8” Strut,15/8”x15/8” Nut,Strut3/8”x1” Bolt,SerratedFlangeHex,3/8” A B C D E F 26.5" 18.25" 39" 64.5" TTCHDGRGDCOGURTOTOOLORMORORMTO TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS H1 PV MODULE HGT. ABOVE ROOF RISE ROOF PITCH OH1 OVERHANG IN THIS AREA UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D2 MODULE WIDTH MAX TRUSS SPACING BALLAST FOOTING O.C. (E) PRE-ENGINEERED TRUSS @ 16" OC MANUF TRUSS / TRUSS - PORTRAIT STANCHION DETAIL STANCHION SPACING DETAIL EXPLODED STANCHION DETAIL EcolibriumSolar EcoFoot 2+ Ecolibrium Solar Ballast Blocks NO PENETRATION 25' MEMBRANE N/A S-200 N/A ECOLIBRIUM PRODUCT ECOLIBRIUM PRODUCT Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT1.2°3" - 10" TYP N/A40.6"64.5" 16" RELEASEREVDATE NAME ADDRESSAPNEQUIP. CALCULATIONSPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STCTEMPERATURE CORRECTEDTEMPERATURE MFR. PMAX TEMPCOEFFICIENT[-0.#%/C] * 100 FORMULA CORRECTEDTEMP.COEFFICIENT MODULE Voc[VDC] TEMPERATURECORRECTEDOPEN CIRCUITVOLTAGE-=*+=*= PV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/THICK PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (SHORT-CIRCUIT POWER)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC AC COMBINER (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) AC SUB-PANEL #2 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS AMPS (Imax) AMPS (Imax) MICRO INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs.DC INPUT Max PV POWER @ MODULE STC WATTS Max INPUT DC VOLTAGE VOLTS DC Max INPUT CURRENT AMPS MODULES PER MICRO INVERTER QTYAC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT #1 (PV) MANUFACTURER AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 (BATTERY) MANUFACTURER AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 ALT. ENERGY BACKFEED BREAKER (IF APPL.)AMPS (Imax) 4 6EXIHGSRXMRSWSXTXTSIVs O:% 4IEOSXTXTSIV O:%WIGSRHW 2SQMREPSPXEIVERI :% 2SQMREPVIUIRGVERI , 6EXIHSXTXGVVIRX % 4IEOSXTXGVVIRX%WIGSRHW 4SIVEGXSVEHNWXEFPIPIEHMRPEMR 1EMQQRMXWTIV%FVERGLGMVGMX RMXWMRPITLEWI -RXIVGSRRIGXMSR7MRPITLEWI 1EMQQ%WLSVXGMVGMXEPXGVVIRXSIVGGPIW %VQW Roundtripefciency² ) 8SXEPGETEGMXO;L 9WEFPIGETEGMXO;L Roundtripefciency 2SQMREP(SPXEI : 1EMQQ(SPXEI : %QFMIRXSTIVEXMRXIQTIVEXVIVERI XSXSRSRGSRHIRWMR 3TXMQQSTIVEXMRXIQTIVEXVIVERI XSXS LIQMWXV0MXLMQMVSRTLSWTLEXI04 )20( (MQIRWMSRW;,(QQQQQQMRMRMR ;IMLX 8LVIIMRHMMHEPOPFWFEWIRMXWTPWOPFWGSIVERHQSRXMRFVEGOIXXSXEPOPFW )RGPSWVI 3XHSSV2)1%XTI6 -5%8QMGVSMRIVXIVIRGPSWVI 2)1%XTI SSPMR2EXVEPGSRIGXMSR2SERW %PXMXHI 9TXSQIXIVWIIX 1SRXMR;EPPQSRX ENERGY STORAGE SYSTEM #1 SPECIFICATIONS ()02))2,%6) ()02))2,%6)42% 4 6EIHGSRMRSWSTTSIV O:% 4IEOSTTSIV O:%WIGSRHW 2SQMREPSPEIVERI :% 2SQMREPVIUIRGVERI , 6EIHSTGVVIR% 4SIVEGSVEHNWEFPIPIEHMRPEMR 1EMQQRMWTIV%FVERGLGMVGM8LVIIRMWWMRPITLEWI -RIVGSRRIGMSR 7MRPITLEWI Roundtripefciency² ) 9WEFPIGETEGMO;L Roundtripefciency 1EMQQ(SPEI : %QFMIRSTIVEMRIQTIVEVIVERI SSRSRGSRHIRWMR 3TMQQSTIVEMRIQTIVEVIVERI SS LIQMWV0MLMQMVSRTLSWTLEI04 )20( (MQIRWMSRW;,(QQQQQQMRMRMR ;IML3RIIEGLOPFWFEWIRMTPWOPFWGSIVERHQSRMRFVEGOISEPOPFW )RGPSWVI 3HSSV2)1%6 SSPMR2EVEPGSRIGMSR2SERW %PMHI 9TSQIIVWII 1SRMR;EPPQSR ENERGY STORAGE SYSTEM #2 SPECIFICATIONS Q-CellsQ.Peak BLK G9 38042.9972.4 x 40.6 x 1.2638045.0437.8510.510.04-0.2720.0 EnphaseIQ7PLUS-72-2-US (240V)2902.38 2906015.01 240201.21 EnphaseX-IQ-AM1-240-3-ES24012523RN/A24.22 EatonDG222URB NON-FUSIBLE DISCONNECT120/2406023RN/A 24.2 EXISTING120/240V Single Phase400400 08035 -20 25 -45 -0.27%0.12 1 1.12 45.04 50.44 50.44 1 E-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMITEatonDG222URB NON-FUSIBLE DISCONNECT120/2406023RN/A21.3 1 RELEASEREVDATE NAME ADDRESSAPNDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUITORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 MAXCURRENT690.8 (A)(1) CONT.OPERATION690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT.TEMP. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILLDERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY DC1 XXX=XX=<WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3. PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT AREEQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED CONDUCTOR(S).TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES ADDRESS kW PHOTOVOLTAIC PLANSWHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED.USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. 4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X = AC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < #OFCOMBINEDPARALLELCIRCUITS QTY INPARALLEL &MATERIAL QTY INPARALLEL &MATERIAL DESTINATION MAX INV. OUTPUTCURRENT (AMPS)ORCOMPONENT(AMPS) lsc (AMPS)ORCOMPONENT(AMPS) PV MODULE INVERTER (1) CU 90 #12 AWG 30 10.5 1 1.25 1.25 16.4 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 16.4 28.8 INVERTER JUNCTION BOX (1) CU 75 #12 AWG 25 1.25 12.1 15.1 ROOFTOP 35 >7/8"0 35 0.94 4 N/A 25 0.94 1.0 23.5 15.1 23.5 AC COMBINER (1) CU 75 #10 AWG 35 1.25 12.1 15.1 ROOFTOP 35 >7/8"0 35 4 0.8 350.94 0.94 0.8 26.32 15.1 26.32 AC DISCONNECT (1) CU 75 #8 AWG 50 1.25 24.2 30.2 EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 30.2 47.0 PRODUCTION METER (1) CU 75 #8 AWG 50 1.25 24.2 30.2 EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 30.2 47.0 SMART TRANSFER SWITCH (1) CU #8 AWG 50 1.25 24.2 30.2 EXT WALL 35 N/A 0 JUNCTION BOX AC COMBINER AC DISCONNECT PRODUCTION METER 75 35 0.94 3 1.0 50 0.94 1.0 47.0 30.2 47.0 E-002WIRE COLOR CODING (2020) NEC SECTIONS 250.119 & 200.6 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMITEXISTING SERVICE PANEL (1) CU #6AWG 65 1.25 24.2 30.2 EXT WALL 35 N/A 0SMART TRANSFER SWITCH 75 35 0.94 3 1.0 65 0.94 1.0 61.1 30.2 61.1 PROTECTED LOADS PANEL (1) CU #8 AWG 50 1.25 24.2 30.2 EXT WALL 35 N/A 0SMART TRANSFER SWITCH 75 35 0.94 3 1.0 50 0.94 1.0 47.0 30.2 47.0 ENERGY STORAGE SYSTEM #2 (1) CU #8 AWG 50 1.25 16 20 EXT WALL 35 N/A 0ENERGY STORAGE SYSTEM #1 75 35 0.94 2 1.0 50 0.94 1.0 47.0 20 47.0 AC DISCONNECT #2 (1) CU #8 AWG 50 1.25 21.3 26.6 EXT WALL 35 N/A 0ENERGY STORAGE SYSTEM #2 75 35 0.94 2 1.0 50 0.94 1.0 47.0 26.6 47.0 SMART TRANSFER SWITCH (1) CU #8 AWG 50 1.25 21.3 26.6 EXT WALL 35 N/A 0AC DISCONNECT #2 75 35 0.94 2 1.0 50 0.94 1.0 47.0 26.6 47.0 LEGEND RELEASEREVDATE NAME ADDRESSTHREE LINE DIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 MICRO INVERTER 3 AC COMBINER BOX 4 JUNCTION BOX 5 NEW SOLAR LOAD CENTER 9 AC DISCONNECT #2 FOR ESS 7 PROD/GENERATION METER 8 PROTECTED LOADS PANEL 10 11 12 EXISTING UTILITY METER TAG APN ADDRESSBRANCH MODULE QTY OCPD BACK-FEED SOLAR BREAKER: TAG QTY*SIZE TYPE DC1 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE AC6 kW PHOTOVOLTAIC PLANSAC7 AC9 AC10 AC8 6 AC DISCONNECT AT GROUND LEVEL * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS 13 ENERGY STORAGE SYSTEM UNIT#1 14 NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND ELECTRICAL NOTES SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS CONDUCTOR TABLE CONDUIT TABLE • •INTEGRATED MICRO INVERTERS (AC MODULES) MUST BE CERTIFIEDUL1742 AND UL1703 COMPLIANT. AS EITHER INDIVIDUALCOMPONENTS OR AC MODULE ASSEMBLY. THEY MUST ALSO BELABELED "UTILITY INTERACTIVE" CONFORMING TO IEEE1547TESTING. •PV MODULES THAT HAVE INVERTERS ATTACHED WITHOUT AN ACMODULE EVALUATION BY A NRTL MAY VIOLATE THE ORIGINALLISTING OF THE PV MODULE AND VOID THE WARRANTY OFTHE MODULE. •VERIFY MODULE IS COMPATIBLE WITH MICRO INVERTERMANUFACTURER AND MODEL. •ARTICLE CEC/NEC 690 STILL APPLIES. THE INSTALLER WILL NEED TO CONSIDER REQUIREMENTS SUCH AS: DC GROUND FAULT DETECTION AND INTERRUPT, DC CABLE MANAGEMENT, DCDISCONNECTING MEANS AND DC GROUNDING AS WELL AS THE ACEQUIPMENT GROUNDING CONDUCTOR TO THE INVERTER. BACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS,UNLESS OTHERWISE MARKED, ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINE” AND “LOAD” SHALL NOTBE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITYINTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BE RATEDFOR 600 VOLTS ON THE DC / PV POWER SIDE OF THE INVERTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FORWET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FOR N G L2 L1PV N G L2 L1 7 L2 L1 G BUSRATING 3 125A L2L1 G N ENVOY-IQFOR MONITORING GEC N 20A 20A 10A Wi-FiEthernet/Cellular Installed L2 L1 L2 L1 GG NN 6 L2 L1 SMART TRANSFER SWITCH L1 L2 N G 35AN L2 L1 G 40A L1 L2 N G G L1 L2 N G ENPHASE ENCHARGE 10 L2 L1G ENPHASE ENCHARGE 3 AC 1413 AC8 AC9 M 12 G N BUSRATING 11 MAIN C/BRATING GEC 400A 400A 10 AC5 BUSRATING125A 40A CONFIGURED AS MAIN OCPD SHALL BE IN COMPLIANCE WITH NEC 408.36(D) N G L2 L1 L2 L1 GG NN 9 AC10 7 READILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT VISIBLE FROMAPPROACH TO RESIDENCE60A 240VLOCATED EXTERIOR ON WALL NEAR METER NEMA 3R RATED READILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT VISIBLE FROM APPROACH TO RESIDENCE 60A 240V LOCATED EXTERIOR ON WALL NEAR METER NEMA 3R RATED 8 AC6 INVERTER NAMEPLATE RATING 290W/240V MODULE NAMEPLATE RATING 380W (-)(+) (-)(+) ACDC AC DC 2 2 10 MODULES 1 1 10 MODULES (+) (+) 2 2 ACDC(-) (-)DCAC 1 1 DC1 EGC AC1 G G L1 L1 L1 L1 L2 L2 L2 L2 L1 L1 L2 L2 4 AC2 AC4AC3 LOCATEDEXTERIOR SOLARGENERATION(LOAD) BOTTOMLUGSTO TOPLUGSTOUTILITY(LINE)MASMARTGENERATIONMETER ENERGY STORAGE SYSTEM UNIT#2 60A THE BATTERY WILL ONLY BE CHARGED BY PV. THE BATTERY WILL DISCHARGE TO ON SITE LOADS. THE BATTERY DISCHARGES TO THE GRID ONLY IF REQUESTED BY THE GRID VIA CONNECTED SOLUTIONS. (2)STRINGS(L1/L2SHOWEN)OF:(10)MODULES NOTE:CONDUCTORSAC3,AC4, AC5, AC6, AC7, AC8, AC9 AND AC10MAYBETHWN-2ORSERCABLE 20 Q-Cells Q.Peak BLK G9 380 Enphase IQ7PLUS-72-2-US (240V) Generic NEMA 4 JUNCTION BOX Eaton DG222URB MA SMART GENERATION METER 1 10 20A 2 10 20A 120/240V - 1 #12 AWG PV Wire Open Air 60A NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER CEC/NEC 705.12(B)(2)(3)(b) 20 1 2 0 1 1 1 1 1 Eaton DG222URB 1 1 2 #6 AWG N/A 5 #12 AWG TRUNK CBL #6 AWG N/A Open Air 5 #10 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #6 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 3 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 3 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 3 #8 AWG THWN-2 #8 AWG 3/4 inch EMT Enphase X-IQ-AM1-240-3-ES 125A BUS/ MLO E-003SMART TRANSFER SWITCH EXISTING MAIN SERVICE PANEL 400A BUS/400A MB Enphase EP200G101-M240US00 1 ENPHASE ENCHARGE-10-1P-NA ENPHASE ENCHARGE-3-1P-NA1 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNELECTRICAL SYMBOL LEGEND SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP AC DISCONNECT PERFORMANCE METER UTILITY METER JUNCTION BOX AC P M ELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES NEED TO BE CONNECTED TO THE EGC(EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSOR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBSARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKINGSPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2.FOR "LAY-IN" LUG MODULE GROUNDING; CORRECTHARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED,TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BEATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TOBOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETAL PARTS THAT MIGHT COME INTO CONTACT WITHCURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THEMETAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS,DISCONNECTS, METERS, JUNCTION BOXES AND COMBINERBOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTSTO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THECONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THESYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT,OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECTCONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING,USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER.THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP ADDRESS kW PHOTOVOLTAIC PLANSAUTO TRANSFORMERATF SOLAR LOAD CENTER ENERGY STORAGE SYSTEM SLC AC COMBINERACC ESS PLP PROTECTED LOADS PANEL JB XFMR TRANSFORMER SUB-PANELSUB STS SMART TRANSFER SWITCH CB CIRCUIT BREAKER DISCONNECTAC#1SPMACCPESSPLPAC#2NORTH JB JB#1ACSTSSCALE: 3/32” = 1’0” @ SHEET SIZE A3QTY 20 Q-Cells Q.Peak BLK G9 380 MODULES, QTY 20 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER E-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSTANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSSHEET NOTES1SCALE:1/2" = 1'-0"CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 2 3 5 6 8 SCALE:1/4" = 1'-0"9 10 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12"FROM BENDS, 12" ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE: NEC 690.31(G)(3)3.MINIMUM OF 1 1/8" x 5 3/4" 4.FONT: 3/8" AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX, DC COMBINER, AND DC DISCONNECT WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SCALE:1/4" = 1'-0" 1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITSOR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSEDDURING SERVICE. 3.MINIMUM OF 3" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. NON-LOAD BREAK DC COMBINER / J-BOX WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SCALE:1/2" = 1'-0" 1.PLACED ON DC DISCONNECT(S) AND ON ANYEQUIPMENT THAT STAYS ENERGIZED IN THE OFFPOSITION FROM THE PV SUPPLY. 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 3 1/2" x 10" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. INVERTER(S)SCALE:1/2" = 1'-0" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 1.A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATEDON OR NO MORE THAN 1M (3 FT) FROM THE SWITCH THATINCLUDES THE FOLLOWING: 2. 3. MINIMUM OF 3 1/2" x 10 1/2" 4. FONT: 3/8" WHITE LETTERS ON A RED BACKGROUND. AC AND DC DISCONNECTS PV SYSTEM DISCONNECT 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 1" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/4" = 1'-0"SCALE:1/4" = 1'-0" DC COMBINER BOX 1. 2. USE PLACARD "COMBINER # 1" WHEN MORE THAN 1DC COMBINER IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1" x 4" 4. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR WHITE LETTERS ON A RED BACKGROUND. 1.CODE REFERENCE: NEC 690.13(C) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1" x 6" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1.USE PLACARD ON CUSTOMER GENERATION METER. 2.VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. SOLAR kWh METER SCALE:1/2" = 1'-0" INVERTER # 1 1.USE PLACARD "INVERTER # 1" WHEN MORE THAN 1INVERTER IS USED. NUMBER ACCORDING TO THREELINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1" x 4" 3.FONT: 3/8" 4.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/2" = 1'-0" USE PLACARD "[AC][DC] DISCONNECT # 1" WHEN MORETHAN ONE DISCONNECT IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 11 SCALE:1/4" = 1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.13 & 690.53) 4.THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLEASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALLTURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOWALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS ANDBARRIERS. (IFC 605.11.1.4, NEC 690.31[G][3] ) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATEOR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOTCOVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THELOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT, NON-BOLD. 7.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA7.4.CONTRASTING BACKGROUND AND LETTERING. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT CODE ABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE (IBC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY (UL) DO NOT DISCONNECT UNDER LOAD 7 RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZEDAND HAVING A MINIMUM HEIGHT OF 9.5 MM (3⁄8 IN.),IN WHITE ON RED BACKGROUND. 2. 1/4" = 1'-0"SCALE: 2CODEREFERENCE:NEC690.56(C)(1)(a) 3TITLE:MIN.3/8"BLACKCHARACTERSONYELLOWBACKGROUND,REMAININGCHARACTERSMIN.3/16"INBLACKONWHITEBACKGROUND. 1LOCATENOMORETHAN1mFROMTHESERVICEDISCONNTMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDSHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDSHUTDOWNSWITCHESIFNOTATTHESAMELOCATION. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS INVERTER(S)P-001QTY 20 Q-Cells Q.Peak BLK G9 380 MODULES, QTY 20 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNDYNAMIC PLACARDS ADDRESS kW PHOTOVOLTAIC PLANS1.PRIME CONTRACTOR / PERMIT APPLICANT SIGNERIS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEMINSTALLATION. PRIME CONTRACTOR / PERMITAPPLICANT SIGNER WILL BE RESPONSIBLE FORCOLLECTION OF EXISTING ONSITE INFORMATIONREQUIREMENTS TO DESIGN, SPECIFY, AND INSTALLTHE EXTERIOR MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEM DETAILED IN THISDOCUMENT. 2.ADVANCED SOLAR SOLUTIONS, INC ISRESPONSIBLE FOR APPLYING SUPPLIEDINFORMATION INTO A SET OF PERMIT DRAWINGS.ANY CHANGES TO DRAWINGS ARE SUBJECT TOCONTRACT CONDITIONS BETWEEN THE CLIENTAND ADVANCED SOLAR SOLUTIONS, INC. INACCORDANCE WITH THE REQUIREMENTS OF THEAHJ. RESPONSIBILITY NOTES SHEET NOTES 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2. 4. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT, NON-BOLD.5.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 5.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS.5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BEREDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT 6.ANSI Z535.4 PRODUCT SAFETY SIGNS AND LABELS: THISINFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDS MAY BE USED WITH PRIOR APPROVAL OF THE AHJ.MOST NOTABLE DIFFERENCES IS COLOR OF PLACARDS AND USEOF HAND WRITTEN VALUES WITH INDUSTRIAL MARKERS ONSTANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT AFUTURE DATE. I.E. ADDING MODULES AT A FUTURE DATE, ORSTANDARD PLACARD MANUFACTURER INSTALLED ONELECTRICAL COMPONENT. AHJ APPROVAL REQUIRED. (SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 2 3 4 SCALE:1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE:1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / AC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.54 4.MINIMUM OF 1 1/2" x 8 1/2" (TOP), 1 3/4" x 6 1/2" (BOT) 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1) PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEMSUPPLY BREAKER AT POINT OF INTERCONNECTION. (#2 & #3) PLACARD(S)REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT ARENOT LOCATED NEXT TO EACH OTHER. MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS. IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS; SEESHEET "E-001 / STRING INVERTER[#] SPECIFICATIONS".2.1.1.INVERTERS ARE PARALLEL CONNECTIONS.2.1.2."RATED AC OUTPUT CURRENT" WILL BE THE SUM OF THE INVERTERS 2.1.3."AC NORMAL OPERATING VOLTAGE" WILL BE THE NAME PLATE RATING OF THEINVERTER 3.CODE REFERENCE: NEC 690.54, NEC 705.12(B)(3) 4.MINIMUM OF 2" x 6 1/2" (#1), VARIES (#2 & #3) 5.FONT: 3/8" HEADER, 3/16" DATA (#1), 1/4" (#2 & #3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PVINVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICEDISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEMDISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 7 3/4" x 5" 6.FONT: 3/4" "CAUTION", 1/4" "WARNING", 3/16" HEADER,1/8" DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEDISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERETHE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRCR331.2.3) MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE:1/2" = 1'-0" CAUTION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND ATTHE PV INVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THESERVICE DISCONNECTING MEANS ANDPHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 6 1/2" x 6 1/2" 6.FONT: 3/4" "CAUTION", 1/4" HEADER, 1/8" DATAAND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAINSERVICE DISCONNECT IN A LOCATION CLEARLYVISIBLE FROM WHERE THE DISCONNECT ISOPERATED. (CFC 605.11.1.3 & CRC R331.2.3) AC COMBINER AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING SCALE:1/2" = 1'-0" 1. 2. USE PLACARD "COMBINER # 1" WHEN MORE THAN 1 AC COMBINER IS USED. NUMBERACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1" x 4" 4. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR MINIMUM. 5. WHITE LETTERS ON A RED BACKGROUND. PLACARDS MAY BE COMBINED TOGETHER. I.E. "AC COMBINER BOX #1". MINIMUM REQUIREMENTS LISTED ABOVE. AC COMBINER / DISCONNECT #1 AC SUB-PANEL #1 AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC COMBINER / DISCONNECT #2 AC SUB-PANEL #2 AC COMBINER / DISCONNECT #3 #1 #2 #3 CODE ABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE (IBC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY (UL) 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.53) N UTILITY METER &SERVICE PANEL PRODUCTIONMETER AC DISCO PROTECTEDLOADS PANEL AC COMBINER SOLAR ARRAYON ROOF TOP N UTILITY METER &SERVICE PANEL PRODUCTIONMETER AC DISCO PROTECTEDLOADS PANEL AC COMBINER ENERGY STORAGESYSTEM SOLAR ARRAYON ROOF TOP AC DISCO SWITCHSMART TRANSFER AC DISCO ENERGY STORAGESYSTEM SWITCHSMART TRANSFER 24.2 240 240 24.2 240 24.2 240 24.2 240 24.2240 240 21.3 21.3 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.6 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (6000 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative 12-busbar design with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Q.PEAK DUO BLK ML-G9+ 365-385 ENDURING HIGH PERFORMANCE 74.4 in 1890 mm 42.5 in 1080 mm 47.6 in 1208 mm 1458 lbs 661 kg 28 24 32 α [% / K]+0.04 β [% / K]−0.27 γ [% / K]−0.35 NMOT [°F]109 ± 5.4 (43 ± 3 °C) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us [V]1000 (IEC)/ 1000 (UL)Class II [A DC]20 TYPE 2 [lbs / ft2]84 (4000 Pa) / 55 (2660 Pa) −40 °F up to +185 °F(−40 °C up to +85 °C)[lbs / ft2]125 (6000 Pa) / 84 (4000 Pa) 3 See Installation Manual 365 370 375 380 385 [W]365 370 375 380 385 [A]10.40 10.44 10.47 10.50 10.53 [V]44.93 44.97 45.01 45.04 45.08 [A]9.87 9.92 9.98 10.04 10.10 [V]36.99 37.28 37.57 37.85 38.13 [%]≥ 19.3 ≥ 19.5 ≥ 19.8 ≥ 20.1 ≥ 20.3 [W]273.3 277.1 280.8 284.6 288.3 [A]8.38 8.41 8.43 8.46 8.48 [V]42.37 42.41 42.44 42.48 42.51 [A]7.76 7.81 7.86 7.91 7.96 [V]35.23 35.48 35.72 35.96 36.20 53' 40' HC CertifiedUL 61730 MECHANICAL SPECIFICATION Format 72.4 in × 40.6 in × 1.26 in (including frame)(1840 mm × 1030 mm × 32 mm) Weight 43.0 lbs (19.5 kg) Front Cover 0.11 in (2.8 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in (53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 47.2 in (1200 mm), (−) ≥ 47.2 in (1200 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and useof this product. Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK ML-G9+_365-385_2020-07_Rev02_NAELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country.Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Maximum Series Fuse Rating Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull3 DETAIL A 0.63" (16 mm) 0.33" (8.5 mm)0.96" (24.5 mm) 42.9" (1088 mm) 72.4" (1840 mm) 4 × Mounting slots (D ETAIL A) Frame 40.6" (1030 mm) 38.6" (981 mm) 1.26" (32 mm) 8 × Drainage holes 15.0“ (376 mm) 4 × Grounding points ø 0.18" (4.5 mm) Label ≥47.2" (1200 mm) ≥47.2" (1200 mm)RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100 95 90 85 80 75 155 2520010YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014) 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENC Y [%]IRRADIANCE [W/m²] QUALIFICATIONS AND CERTIFICATES PACKAGING AND TRANSPORT INFORMATION UL 61730, CE-compliant, IEC 61215:2016, IEC 61730:2016, U.S. Patent No. 9,893,215 (solar cells) Horizontalpackaging pallets pallets modules RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSPV MODULE CUT SHEET R-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT IMTSIIQEMIE EIMEREIM EQEMEPPMQTPMIMREPPEMSRTSIMPI achievingthehighestsystemefciency. ESIRTEI-7IQI-ER -MSMRIIMRIEIMIRTEI -RSRTEI-EIERIRTEI Enlighten™monitoringandanalysissoftware. -7IMIMSMRIIIIRIIPMEMPM EREISTIMSIRIEMSRER RISSIEQMPPMSRSSTSISRIMR IREPMRRTEISTSMIERMRPIEMR warrantyofupto25years. EI E MMII 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ EE7IIEIMMIIIMSR-7 )EWXS-RWXEPP 0MLXIMLXERHWMQTPI *EWXIVMRWXEPPEXMSRMXLMQTVSIHPMLXIVXSMVIGEFPMR &YMPXMRVETMHWLYXHSRGSQTPMERX2) 4VSHYGXMIERH6IPMEFPI 3TXMQMIHSVLMLTSIVIHGIPPLEPGIPPERHGIPPLEPGIPPQSHYPIW 1SVIXLEREQMPPMSRLSYVWSXIWXMR PEWW--HSYFPIMRWYPEXIHIRGPSWYVI 90PMWXIH 7QEVX+VMH6IEH SQTPMIWMXLEHERGIHVMHWYTTSVXSPXEIERHVIUYIRGVMHIXLVSYLVIUYMVIQIRXW 6IQSXIPYTHEXIWXSVIWTSRHXSGLERMR VMHVIUYMVIQIRXW • Congurableforvaryinggridproles 1IIXW%6YPI907% 8LI-51MGVSMWVIUYMVIHXSWYTTSVXGIPPLEPGIPPQSHYPIW 2SIRSVGIH(%VEXMS7IIXLIGSQTEXMFMPMXGEPGYPEXSVEXLXXTWIRTLEWIGSQIRYWWYTTSVXQSHYPIGSQTEXMFMPMX2SQMREPSPXEIVERIGERFIIXIRHIHFISRHRSQMREPMVIUYMVIHFXLIYXMPMX0MQMXWQEEV6IIVXSPSGEPVIUYMVIQIRXWXSHIMRIXLIRYQFIVSQMGVSMRIVXIVWTIVFVERGLMRSYVEVIE 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ ©2020EnphaseEnergy.Allrightsreserved.Enphase,theEnphaselogo,EnphaseIQ7,EnphaseIQ7+,EnphaseIQBattery, EnphaseEnlighten,EnphaseIQEnvoy,andothertrademarksorservicenamesarethetrademarksofEnphaseEnergy,Inc.Datasubjecttochange.2020-08-12 -2((-7 -77 SQQSRPYWIHQSHYPITEMVMRWz ;;;; 1SHYPIGSQTEXMFMPMXGIPPLEPGIPP4:QSHYPIWSRPGIPPLEPGIPPERHGIPPLEPGIPP4:QSHYPIW 1EMQYQMRTYX(SPXEI :: 4IEOTSIVXVEGOMRSPXEI :::: 3TIVEXMRVERI :::: 1MR1EWXEVXSPXEI :::: 1E(WLSVXGMVGYMXGYVVIRXQSHYPI-WG%% 3IVSPXEIGPEWW(TSVX ---- (TSVXFEGOIIHGYVVIRX %% PVarrayconguration YRVSYRHIHEVVE2SEHHMXMSREP(WMHITVSXIGXMSRVIUYMVIH%WMHITVSXIGXMSRVIUYMVIWQE%TIVFVERGLGMVGYMX (-MVSMIVIV -MVSMIVIV 4IEOSYXTYXTSIV :%:% 1EMQYQGSRXMRYSYWSYXTYXTSIV :%:% 2SQMREP00SPXEIVERIs :::::::: 1EMQYQGSRXMRYSYWSYXTYXGYVVIRX %:%:%:%: 2SQMREPVIUYIRG,, )XIRHIHVIUYIRGVERI ,, %WLSVXGMVGYMXEYPXGYVVIRXSIVGGPIW %VQW %VQW 1EMQYQYRMXWTIV%00FVERGLGMVGYMXt :%:%:%:% 3IVSPXEIGPEWW%TSVX ------ %TSVXFEGOIIHGYVVIRX Q%Q% 4SIVEGXSVWIXXMR 4SIVEGXSVEHNYWXEFPIPIEHMRPEMRPIEHMRPEMR )--)2 Peakefciency CECweightedefciency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kW PHOTOVOLTAIC PLANSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT 8IEEESISTIWSEI WWIWEEEE-EWESE WEIIIETESEIWS IIISSIIW TSIE-TSIWETETEEWEIW EIWIWWIWISIII needsofbothnewandretrotsolarcustomers. E E 8SPIEVRQSVIEFSX)RTLEWISIVMRWMWMXIRTLEWIS EEII ESE 6IPMEFPI 4VSIRLMLVIPMEFMPMX-57IVMIW1MGVSMRIVXIVW 8IRIEVPMQMXIHEVVERX SVIQFIHHIH-5%81MGVSMRIVXIVW 4EWWMIGSSPMRRSQSMRTEVXWERW 7QEVX VMHSVQMRGETEFMPMXSVFEGOTSTIVEXMSR • Remotesoftwareandrmwareupgrade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oundtripefciency² ) 8SXEPGETEGMXO;L 9WEFPIGETEGMXO;L Roundtripefciency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t GETEGMXTXSIEVWSVGGPIW 7TTSVXIHMRFEGOTSVMHSTIVEXMSR%XSFEXXIVXS%EXTSIVVEXMR3.Whicheveroccursrst.Restrictionsapply. EE 8SPIEVRQSVIEFSX)RTLEWISIVMRWMWMXIRTLEWIS kTEWIIWIWIITEWIITEWISSEIESIEIEWSWIIEIWEIIEIEWSTEWII-EEWISEIRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSBATTERY CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANS8IEEESISTI WSEIWWIWEEEE-W STWISIIEWIEIWSEIWEW ESEWEIIIETESEII IIISSIIW TSIE-TSIWETETEEWEIW EIWIWWIWISIII needsofbothnewandretrotsolarcustomers. E E 8SPIEVRQSVIEFSX)RTLEWISIVMRWMWMXIRTLEWIS EEII ESE 6IPMEFPI 4VSIRLMLVIPMEFMPMX-57IVMIW1MGVSMRIVXIVW 8IRIEVPMQMXIHEVVERX 8LVIIMRHITIRHIRX)RGLEVIWXSVEIFEWIRMXW 8IPIIQFIHHIH-5%81MGVSMRIVXIVW 4EWWMIGSSPMRRSQSMRTEVXWERW 7QEVX VMHSVQMRGETEFMPMXSVFEGOTSTIVEXMSR • Remotesoftwareandrmwareupgrade 1SFMPIETTFEWIHQSRMXSVMRERHGSRXVSP 7TTSVXSVWIPGSRWQTXMSR 9XMPMXXMQISWI839STXMQMEXMSR 7MQTPI PPMRXIVEXIH%FEXXIVWWXIQ 5MGOERHIEWTPERHTPEMRWXEPPEXMSR -RXIVGSRRIGXWMXLWXERHEVHLSWILSPH%MVMR 7EI IPPWWEIXXIWXIH 0MXLMQMVSRTLSWTLEXI04GLIQMWXVSVQEMQQ WEIXERHPSRIMX ()02) )2,%6)42%)RGLEVIFEXXIVWXSVEIWWXIQMXLMRXIVEXIH)RTLEWI1MGVSMRIVXIVWERHFEXXIVQEREIQIRXRMX19-RGPHIW8LVII)RGLEVIO;LFEWIRMXW%973RI)RGLEVIGSIVOMXMXLGSIVEPPQSRXMRFVEGOIXEXIVXMLXGSRHMXLFWERHMRXIVGSRRIGXOMXSVMVMRFIXIIRFEXXIVMIW3 )) )2,%6),2(063RIWIXS)RGLEVIFEWIRMXMRWXEPPEXMSRLERHPIW 4 6EXIHGSRXMRSWSXTXTSIVs O:% 4IEOSXTXTSIV O:%WIGSRHW 2SQMREPSPXEIVERI :% 2SQMREPVIUIRGVERI , 6EXIHSXTXGVVIRX % 4IEOSXTXGVVIRX%WIGSRHW 4SIVEGXSVEHNWXEFPIPIEHMRPEMR 1EMQQRMXWTIV%FVERGLGMVGMX RMXWMRPITLEWI -RXIVGSRRIGXMSR7MRPITLEWI 1EMQQ%WLSVXGMVGMXEPXGVVIRXSIVGGPIW %VQW Roundtripefciency² ) 8SXEPGETEGMXO;L 9WEFPIGETEGMXO;L Roundtripefciency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t GETEGMXTXSIEVWSVGGPIW 7TTSVXIHMRFEGOTSVMHSTIVEXMSRW%XSEXXIVXS%EXTSIVVEXMR3.Whicheveroccursrst.Restrictionsapply. EE 8SPIEVRQSVIEFSX)RTLEWISIVMRWMWMXIRTLEWIS kTEWIIWIWIITEWIITEWISSEIESIEIEWSWIIEIWEIIEIEW STEWII-EEWISEI BATTERY CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/22/2021SUBMIT FOR PERMIT IEEVMSII SISVMTSIVI)EVISVEII ESPEV-TVSMIMVSVMMIVSIMS IMI1-(MSEPMESEMEPPIIM EIEPIPVEMMSMISIIIVI VSVMTSIVSETTSIVMIIISEVM EMPVI-SSPMEIMIVSIMSIMTIMS EMPIIPSVIEVIEPMIVMMITII ETEMPMMISESVEIMEPPEMS TVSMMESMITVIMVISPMSSV VIMIMEPETTPMEMS E 8SPIEVRSVIEFSX)RTLEWISIVMRKWMWMXIRTLEWIS (EEIIEIIVEEIII 6IPMEFPI (VEFPI2)1%XTI6IRGPSWVI 8IRIEVPMMXIHEVVERX 7EVX SRXVSPWWEIGSRRIGXMMXXSXLIKVMH %XSEXMGEPPHIXIGXWKVMHSXEKIW 4VSMHIWWIEPIWWXVERWMXMSRXSFEGOT 7MTPI SRRIGXWXSXLIPSEHSVWIVMGIIUMTIRXzWMHI SXLIEMRPSEHTERIP IRXIVIHSRXMRKFVEGOIXWWTTSVXWMRKPIWXH SRXMRK 7TTSVXWGSRHMXIRXVVSXLIFSXXSFSXXSPIXWMHIERHFSXXSVMKLXWMHI 7TTSVXWLSPILSIERHTEVXMEPLSIFEGOT ERHWFTERIPFEGOT 9TXS%EMRFVIEOIVWTTSVX -RGPHIWRIXVEPSVMRKXVERWSVIVSVWTPMX TLEWI:FEGOTSTIVEXMSR )RTSIVMWRSXWMXEFPISVWIEWWIVMGIIUMTIRXMREREHE8SPIEVRSVIEFSX)RTLEWISIVMRKWMWMXIRTLEWIS k)TEI)IVPPVMVIIVI)TEII)TEIPSS)TSIVESIVVEIEVSVIVMIEIEVIIVEIEVS)TEI)IV-(EEISEI )4+197)RTLEWI)RTSIVWEVXWMXGLMXLRIXVEPSVMRKXVERWSVIV281MGVSKVMH-RXIVGSRRIGX(IMGI1-(FVIEOIVWERHWGVIW7XVIEPMRIWKVMHMRHITIRHIRXGETEFMPMXMIWS4:ERHWXSVEKIMRWXEPPEXMSRW ERH %)4%)27 6ITPEGIIRX)RTSIVGSRXVSPPIVTVMRXIHGMVGMXFSEVH MVGMXFVIEOIVWEWRIIHIH 6/%4: 6/%4: 6/%4:6/%4: 6/%4: 6/%4: 6/%4: 6/%4:6/%4: 6/%4: 2SXMRGPHIHWXSVHIVWITEVEXIP 1EMRFVIEOIVTSPI%O%-762SV761EMRFVIEOIVTSPI%O%-762 1EMRFVIEOIVTSPI%O%-7621EMRFVIEOIVTSPI%O%-7621EMRFVIEOIVTSPI%O%-762 MVGMXFVIEOIVTSPI%O%-6MVGMXFVIEOIVTSPI%O%-6 MVGMXFVIEOIVTSPI%O%-6MVGMXFVIEOIVTSPI%O%-6MVGMXFVIEOIVTSPI%O%-6 )4+,2(06)RTSIVMRWXEPPEXMSRLERHPIOMXSVHIVWITEVEXIP %WWIFPVEXMRK SRXMRSWSTIVEXMSREXSMXWVEXMRK 2SMREPSPXEKIVERKI00:%:% :SPXEKIIEWVIIRXEGGVEGr:RSMREPr:02ERHr:00 2SMREPVIUIRGVERKI ,, VIUIRGIEWVIIRXEGGVEGr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kW PHOTOVOLTAIC PLANSSMART TRANSFER SWITCH CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT | 740-249-1877 | www.ecolibriumsolar.com Three main components PVinstallationProfessionalsuseEcoFoot2+tocompletetheirprojectsin recordtime.TherefreshedEcoFoot2+designisnowavailableinBlack, alongwithacomprehensiveUL2703certification. Base OurnewUL-ListedASAbased resinisadurablematerialcommonly usedinautomotiveandconstruction applications.Thematerialis classAfireratedaspartof ourUL2703Certification. PreassembledUniversalClamp Thenewpreassembleduniversal clampachievesintegratedgrounding withouttheuseofgroundingwashers. TM Back in Black PV installation Professionals use EcoFoot2+ to complete their projects in record time. The refreshed EcoFoot2+ design is now available in Black, along with a comprehensive UL2703 certification. WindDeflector Corrosion-resistantwind deflectoroneverymodulehelps minimizeuplift,reduceballast requirementsandcarriesUL2703 validatedgroundpathfrom modulesandrackingcomponents. 1ooo System Benefits Lowpartcount Rapidsystemdeployment PreassembledUniversalClamp Increaseddesignflexibility Moreballastcapacity Simplifiedlogistics (upto50kWperpallet) Validation Summary CertifiedtoUL2703FireClassA forTypeIandIImodules CertifiedtoUL2703 GroundingandBonding Windtunneltestedto150mph SEAOCseismiccompliant CFDandstructurallytestedDNVGL ratedat13.5panelsperinstaller-hour — — — — — — — — — — — Technical Specification s Dimensions:26.5”Lx18.25”Wx8.3”H TypicalSystemWeight:3.5–6lbs.persq.ft. Moduleorientation:Landscape/Portrait Tiltangle:Landscape10°/Portrait5° Moduleinter-rowspacing:18.9” Roofpitch:0°to7° Ballastrequirements:4”x8”x16” Warranty:25years EcoFoot2 + Installer Feedback = EcoFoot2+™ Our design enhancement s help you master the most challenging site an d rooftop conditions 1oooRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT Business Stream Products Renewable and Solar Technology TÜV Rheinland PTL Photovoltaic Testing Laboratory 2210 South Roosevelt Street Tempe, Arizona 85282 Main Phone: 480-966-1700 Main Fax; 775-314-6458 Email: info@tuvptl.com TÜV Rheinland North America Holding, Inc. 1 Federal Street Boston, MA 02110 Main Phone: 617-426-4888 Main Fax: 617-426-6888 Member of TÜV Rheinland Group Attn: Mr. Chad Parsons Ecolibrium Solar 340 West State Street Athens, OH 45701 USA Email: jcastagna@us.tuv .com 480-966-1700, x153 June 16, 2014 UL SU 2703 Bonding Tests Completed Type of Equipment: PV Mounting System Model Designation: Ecolibrium Solar Ecofoot2+ Test Requirement: UL Subject 2703 TÜV Rheinland File Number: L1-ELS130905 TÜV Rheinland Project Number: ELS130905 Dear Mr. Parsons, This letter is confirmation that the Ecolibrium Solar Ecofoot2+ PV Mounting System has successfully completed electrical bonding tests according to the UL Subject 2703 standard. Congratulations on this achievement. All summary test results will be provided to you separately when the full report is completed. The final Test Report and associated Constructional Data Form (CDF) will be submitted to our certification department for final processing and subsequent listing on the TUV Rheinland Certipedia website. You may use this correspondence as an interim Letter of Compliance (LOC) indicating your system has met the relevant bonding requirements of UL Subject 2703. Sincerely, Jack Castagna Solar Components Program Manager TÜV Rheinland PTL, LLC RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT KN FRIRR3OVB,VDOOBLGB9,1/-o -DDU6FROLEULPVRODUFRP hhD / t d FRIRR3OVB,VDOOBLGB9,1/-o -DDU6FROLEULPVRODUFRP uom7bmom7bm ddsh t/ EE/EW tt K t tht K ,:,: t EhD& hEh E ERELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANS 44 Ward Ave 44 Ward Ave, Northampton, MA 01060 September 2, 2021 SOLUTION OVERVIEW VICINTY MAP PROJECT SPECIFICATIONS Total System Size (KW)7.6 Total Module Quantity 20 Module Orientation Landscape Module Manufacturer Hanwha Q.Cells Module Model Q.PEAK DUO BLK G9+ 380 Module Wattage 380 Module Length (in.)72.44 Module Width (in.)40.55 Module Weight (lbs)42.99 Roof Type EPDM Membrane Parapet Height (in)0 Setback (in)28 Roof Height (ft)30 Roof Slope (degrees)1.20 ASCE Version 2010 Basic Windspeed (mph)117 Wind Exposure Category B Occupancy Category II Ground Snow Load (lb/ft2)40 SOLAR PROJECT DESIGN With 500MW installed, EcoFoot Racking is preferred by installers for fast, simple installation and streamlined logistics. The enclosed provides the layout and system details for a complete solution for your project using this validated and reliable product. Installers complete projects in less time with self-aligning Bases, simple pre-assembled components, five-minute learning curve, and one-tool installation. Install speed is rated at 13.5 modules/installer-hour by DNV-GL. EcoFoot2+ consists of three core components: roof friendly, durable Base with integrated north/south Wire Clips, pre-assembled Clamps, and Wind Deflector to reduce ballast and provide east/west bonding. Stackable Bases fit up to 50kW per pallet, meaning fewer crane lifts and less space used on the job site. Experienced project managers and field technicians support your project from bid to inspection. Project managers ensure you have needed details to obtain a permit and pass inspection. Our field team offers a dedicated phone line and email. On-site training is available. DESIGN IS FINALIZED WHEN ACCOMPANIED BY STAMPED ENGINEERING REPORT. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ROOF CAPACITY. CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL DESIGN CRITERIA ARE CORRECT AND APPROPRIATE FOR THE PROJECT SITE. CONTRACTOR MUST CONFIRM DESIGN MEETS ALL UTILITY AND AHJ REQUIREMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT BUILDING STRUCTURE AND RELATED CONNECTIONS CAN SUPPORT ALL LOADS IMPOSED BY PV SYSTEM. REFER TO INSTALLATION MANUAL FOR FULL PRODUCT DETAILS AND ADDITIONAL INFORMATION. BALLAST REPORT R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSInstaller Name: Project Name: Project Address: Date Prepared: Introduction, Site Specifics and Variable Definition………………………………………………………………………Page 2 Wind Tunnel Testing, Uplift and Drag Force Calculations……………………………………………………………….Page 3 Ballast Application to Sheet S-1.0……………………………………………………………………………………….Page 5 Detailed Calculations From Table 4……………………………………………………………………………………………Page 7 SEAOC PV1 - 2012 - Section 4: Attached Arrays………………………………………………………………………………………Page 8 Table 1: System Design Criteria………………………………………………………………………………………….. Table 2: PV Module Specifics………………………………………………………………………………………………. Table 3: Calculation Inputs, Constants, and Variables…………………………………………………………………………… Table 4: Ballast to Resist Uplift Calculations for the Above Address………………………………………………………… Image 1: Aerodynamic Zones From RWDI Report……………………………………………………………………………………… Table 5: Ballast to Resist Sliding Calculations…………………………………………………………………………………………………… Image 2: Ballast to Resist Sliding Equation from RWDI………………………………………………………… Image 3: Example of Module and Ballast Graphical Representation………………………………………………………… Image 4: Ballast Prescriptions Produced by Table 4 ………………………………………………………… Table 6: Seismic Design Inputs…………………………………………………………………………………………………... Table 7: ASCE7 Inputs……………………………………………………………………………………… Table 8: Calculation of Physical Attachment Requirements……………………………………………………………………………………… Image 5: Example of ballast layout with seismic attachment callouts……………………………………………………………………………………… ……………………………………………………………………………………………………………………………………………………………………….. Rowan, Williams, Davies, & Irwin Inc (RWDI) -- Wind Tunnel Testing Per ASCE 7 / IBC Maffei Structural Engineering -- Peer Review of Wind Tunnel Testing Testing Engineers, Inc. -- Friction Testing per ASTM G115 CBC Engineers -- Professional Engineering Review and Certification Table Of Figures: 3rd Party Engineering Resources Explanation of EcoFoot System Calculations and Design Procedure Calculation Explanation Key Sections: Uplift, Sliding and Seismic Calculations Valley Solar 44 Ward Ave 44 Ward AveNorthampton, MA 01060 9/2/2021 …………... Page 2 Page 2 Page 3 Page 4 Page 4 Page 5 Page 5 Page 6 Page 6 Page 8 Page 8 Page 9 Page 9 ecolibriumsolar.com Page 2 507 Richland Ave., Athens, OH 45701 740-249-1877 Uplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 *req's slip sheets Utilizing the inputs from Tables 1 and 2, the factors in Table 3 are generated for the site. This list of factors is used in various ways to fully define a proposed system according to calculations laid out in the SEAOC and ASCE documents. In the scope of this explanation, factors are used to calculate velocity pressure, qh as defined in ASCE7-05, Section 6.5.10; ASCE7-10, Section 30.3.2; or ASCE7-16, Section 26.10.2, and ultimately the amount of ballast required to offset uplift and drag forces. Product Line EcoFoot 2+ Module Manufacturer Module Model Q.PEAK DUO BLK G9+ 380 Hanwha Q.Cells 380Module Power (w) Module Weight (lbs.) Module Length (in)Module Width (in) Introduction, Site Specifics and Variable Definition In order to efficiently design EcoFoot2+ and EcoFoot5D ballasted photovoltaic systems, Ecolibrium Solar makes use of a proprietary solar array design aid called “EcoCalcs”. Starting with a set of design criteria, shown here in Table 1 below, EcoCalcs utilizes methodologies laid out in the ASCE7 and SEAOC PV1/PV2 documents, and derivative building codes. Actual calculations for this project are included herein, and are accompanied by a step-by-step explanation of Ecolibrium Solar's design process. The output of EcoCalcs is a comprehensive set of ballast prescriptions, including Image 3 found on Page 5. Ballast prescriptions are applied to a proposed system layout by the Ecolibrium Solar engineering team. CBC Engineers, Ecolibrium Solar's professional engineering partner, has reviewed and verified EcoCalcs and reviews system designs to ensure that calculations and ballast prescriptions were correctly applied. Upon successful review, CBC Engineers provides a stamped design review including relevant supporting documentation (this explanation included) and a stamped, approved ballast plan. Please note: Ecolibrium Solar and CBC engineers are not conducting a structural review of the proposed site. Table 2: PV Module Specifics 117 Min Edge Setback (in)Module Orientation Landscape D 40.0 0.1710Soil Site Class Snow Load (psf)Seismic Data (SS) 72.4440.55 42.99 Below, Table 1 and Table 2 list the design criteria and project details for a proposed system in Northampton, MA. These values will be used throughout the remainder of this explanation. 2010 EPDM Membrane ASCE7 Version Roof Type Table 1: System Design Criteria 0.49Coeff. Of Friction (fn)* N/AGround Elevation (ft) Occupancy Category 28 301.20 Wind Exposure 3 Sec. Gust (mph) B Parapet Height (in.) Roof Slope (deg)Roof Height (ft.) 0 II ecolibriumsolar.com Page 3 507 Richland Ave., Athens, OH 45701 740-249-1877 BALLAST REPORT R-109Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSUplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 Racking Component Weight per Module lbs. lbs. ft2 ft2 lbs. in. ft. ft. ft. Wind tunnel testing of the EcoFoot product line to determine GCn values has been conducted by Rowan Williams Davies & Irwin Inc. (RWDI), a nationally recognized boundary-layer wind tunnel test firm. Testing was conducted in accordance with ASCE7-05, section 6.6; and ASCE7-10 or 16, section 31.2. Module-specific GCn data allows for precise application of ballast to prevent uplift. Deviation from prescriptive wind GCn values has been addressed according to SEAOC PV2 via a peer review of the wind tunnel testing and results by Maffei Structural Engineering. GCn and qh are used to calculate the pressure exerted on each module via the design wind pressure equations (ASCE7- 05 – section 6.5.12.4, ASCE7-10 – section 30.4.2, ASCE7-16 – section 30.5.1). Ballast required to offset uplift and drag forces (BWUz) is calculated with load combination calculations from ASCE7-05/10 section 2.3.2, or ASCE7-16 section 2.3.1. Detailed calculations for this project are found in Table 4. Resulting required ballast BWUz is displayed graphically in Image 3. Wind Tunnel Testing, Uplift and Drag Force Calculations 0.6 20.87 zmin (from ASCE7 Table 6-2)= z selected (from zmin & inputs)= Kz= Adjustment Factor for Building Height and Exposure Wind design load factor 0.6 Kzt= Topographic Factor 1 0.85 I= Importance Factor 32 zg (from ASCE7 Table 6-2 or 26.9.1)= Load Combination Factor for Wind 0.6 Roof Setback Minimum α (from ASCE7 Table 6-2 or 26.9.1)= Load Combination Factor for Seismic 1200 30 30 20.133 28 1 Ballast Block Weight Asymmetric lift load Ratio (North Row) Asymmetric lift load Ratio (South Row) Ala= Effective Lift Area of PV Module 57.533 3.28 1.4 1.6 Ada= Effective Drag Area of PV Module dLF1= Dead Load of Module and Attributed Racking qh= Velocity Pressure (0.00256*Kz*Kzt*Kd*V2*I) Dead Load design load factor 14.54 Table 3: Calculation Inputs, Constants, and Variables 1Ke= Ground Elevation Factor 0.70 0.7 7 Kd= Directionality Factor An explanation of variables: Asymmetric Lift Load Ratio: This is a ratio describing the leverage created by EcoFoot base dimensions, module attachment location and location of center of ballast mass. Assessed as a multiplier on top of ballast distribution scheme in Image 4. dLF1= Dead Load of Module and Attributed Racking: the weight of one module and hardware attributed to that module, not including ballast. Ala= Effective Lift Area of PV Module:The surface area of a module projected onto the horizontal plane for lift calculations. Ada= Effective Drag Area of PV Module: The surface area of a module projected onto the horizontal plane for drag calculations. qh= Velocity Pressure at height "h":Calculation prescribed by ASCE7-05, eq. 6-15, and ASCE7-10, eq. 30.3-1, or ASCE7-16, eq. 26.10-1(subscript "h" used here for clarity, ASCE7 utilizes subscript "z"). ecolibriumsolar.com Page 4 507 Richland Ave., Athens, OH 45701 740-249-1877 Uplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 pUz=Uplift design wind pressure =qh*GCnUz WLFUz=Uplift wind force =pUz*Ala DLFUz=Net ASD uplift = dLF1*0.6 + WLFUz*0.6 BWuz=ballast required = -DLFUz/0.6 pUz=Uplift design wind pressure =qh*GCnUz WLFUz=Uplift wind force =pUz*Ala DLFUz=Net ASD uplift = dLF1*0.6 + WLFUz*0.6 BWuz=ballast required = -DLFUz/0.6 pUz=Uplift design wind pressure =qh*GCnUz WLFUz=Uplift wind force =pUz*Ala DLFUz=Net ASD uplift = dLF1*0.6 + WLFUz*0.6 BWuz=ballast required = -DLFUz/0.6 pUz=Uplift design wind pressure =qh*GCnUz WLFUz=Uplift wind force =pUz*Ala DLFUz=Net ASD uplift = dLF1*0.6 + WLFUz*0.6 BWuz=ballast required = -DLFUz/0.6 pUz=Uplift design wind pressure =qh*GCnUz WLFUz=Uplift wind force =pUz*Ala DLFUz=Net ASD uplift = dLF1*0.6 + WLFUz*0.6 BWuz=ballast required = -DLFUz/0.6 pUz=Uplift design wind pressure =qh*GCnUz WLFUz=Uplift wind force =pUz*Ala DLFUz=Net ASD uplift = dLF1*0.6 + WLFUz*0.6 BWuz=ballast required = -DLFUz/0.6 -29.0 lbs -6.0 -121.0 -38.1 63.5 lbs lbs lbs psf lbs lbs Load Sharing Area -4.8 -95.8 -23.0 38.3 -4.3 -85.7 -16.9 28.2 3x3 -4.8 -95.8 -23.0 38.3 -4.3 -85.7 -131.1 -44.1 73.6 3x23x3 -110.9 -32.0 3x22x32x2#col x #rows -131.1 -44.1 73.6 psf lbs. lbs lbs psf lbs lbs lbs psf lbs lbs lbs psf lbs lbs -6.5 -131.1 -44.1 73.6 -6.0 -121.0 -38.1 63.5 -6.5 -29.0 48.3 -38.1 63.5 -6.5 -6.0 -121.0 53.4 -5.0 -100.8 -26.0 43.3 -5.8 -116.0 -35.1 58.4 -5.3 -105.9 -29.0 48.3 -5.5 -110.9 -32.0 53.4 -5.3 -105.9 -29.0 48.3 48.3 -5.5 -5.3 -105.9 -23.0 38.3 -4.3 -5.3 -105.9 -105.9 -29.0 48.3 -5.0 -100.8 -26.0 43.3 -5.3 -105.9 -95.8 -23.0 38.3 -4.3 -85.7 -16.9 28.2 -4.8 -95.8 -4.8 -4.8 -5.3 -29.0 48.3 -5.0 -100.8 -26.0 43.3 -26.0 43.3 12.5 -16.9 28.2 -95.8 -23.0 38.3 -4.3 -85.7 -16.9 28.2 Down (1x1) -85.7 -16.9 28.2 -5.3 -105.9 -29.0 48.3 -5.0 -100.8 -26.0 43.3 -5.3 48.3 -5.0 -100.8 16.3 16.3 lbs psf -4.8 43.3 -16.9 Table 4: Ballast to Resist Uplift Calculations for Project Proposed in Northampton, MA 01060 North CornerNorth Edge12.5 16.3 South EdgeFieldE/W Edge-5.3 -105.9 -29.0 South CornerImage 1: Aerodynamic Zones from RWDI Report The aerodynamic differences among different sub-sections of a large array are handled by various calculation sections (North Corner, North Edge, E/W Edge...) and apply according to the excerpt from the RWDI report shown below in Image 1. The highlighted sections of Table 4 correspond to specific module locations, also shown in Image 4: green - the north corners, purple - the east or west edge, orange - the deep interior. See Page 7 for expanded calculations pertaining to the highlighted sections. -105.9 -29.0 48.3 -5.0 -100.8 -26.0 12.5 -95.8 -23.0 38.3 -4.3 -85.7 28.2 ecolibriumsolar.com Page 5 507 Richland Ave., Athens, OH 45701 740-249-1877 BALLAST REPORT R-110Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSUplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060Uplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 For easier interpretation, the results calculated in Table 4 are laid out in graphical representations of a solar array, shown in Image 4. Ecolibrium Solar engineers and drafters make use of this graphical layout when applying ballast to a given system design. As shown in Image 3, the ballast required to resist lift - BWUz from Table 4 - is listed for each module location in Image 4. A portion of each BWUz value is distributed to each of the connected EcoFoot Bases, also detailed in Image 3 and included in Image 4. The total ballast required at each EcoFoot location is then calculated and rounded up to the next ballast block increment. Ballast Application to Sheet S-1.0 To check the amount of drag a given sub-array will experience, the equation in Image 2 is utilized - an excerpt from RWDI's test report. Each sub-array is checked for sliding, proceeding from the smallest to largest or until drag no longer governs total required ballast. Table 5 lists the calculations used to identify the total required ballast to counteract drag forces and prevent sliding. Friction values have been identified by Testing Engineers (IAS accredited) according to ASTM G115 - Standard Guide for Measuring and Reporting Friction Coefficients. Unless detailed information is available pertaining to the location of the sub-array, the roof's worst case uplift GCp are utilized in calculating drag and required ballast. 1627.16 0.22 0.47 0.34 -0.65 Image 2: Ballast to Resist Sliding Equation 0.49 (GCp)*drag = 0.6 Table 5: Ballast to Resist Sliding Calculation Sub-Array Module Count Total: Area Reduction Factor = ad = Dead Load Combination Factor = qz (qh in Table 3)= M = dLF1 from Table 3 = fn (also see Table 1) = Auplift = Ala in Table 3 = 0.6 GCp-drag GCp-uplift 57.53 3.28 1.38 20.13 32 20.87 16aw = Wind Load Combination Factor = Wballastblock = Total Required Ballast Blocks:51 Total Required Ballast Weight (Per Image 2)= Adrag = Ada in Table 3 = |GCp|*uplift = ecolibriumsolar.com Page 6 507 Richland Ave., Athens, OH 45701 740-249-1877 Uplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 EcoFoot 2+ Ballast Layout EcoFoot 5D Ballast Layout 2 2 1 2 2 1 2 2 1 1 2 2 2 2 2 0 0 2 2 2 1 1 1 0 0 2 2 2 2 1 1 0 0 2 2 2 2 1 1 0 0 N 2 2 2 2 1 1 0 0 2 2 2 2 1 1 0 0 2 2 2 2 1 1 0 0 2 2 2 2 2 2 0 0 2 2 2 2 2 2 0 0 Array Continues Inward, Is Symmetric About CenterlineNOTE: The colored module locations in Image 4 correspond to the same colored areas in Table 4: green - the north corners, purple - the east or west edge, orange - the deep interior. See Page 7 for more detailed calculations. 0 0 0 00 52.47 1 Break Line (green dashed line) Module, with required ballast weight "BWUz" called out 27.36 27.36 53.38 38.26 EcoFoot location with required number of ballast blocks 00 43.3073.55 48.3448.34 2 52.47 27.36 2 53.38 38.26 28.18 28.18 0 73.55 28.18 28.18 43.30 The ballast prescription array shown in Image 4 is one of many similar arrays created automatically through EcoCalcs in order to address all possible array configurations. The data calculated in Table 4 was ultimately used to assign ballast to the system design in Sheet S-1.0 by Ecolibrium Solar. EcoCalcs and the resulting ballast plan S-1.0 are reviewed by CBC Engineers for correctness and completeness. Once approved, an engineering report including Sheet S-1.0 and any supporting material (this explanation included) are stamped and sealed by a professional engineer registered in the state where the project is proposed. Image 4: Ballast Prescriptions Produced by Table 4 000 0 0 0 0 0 48.34 48.34 43.30 0 0 38.26 0 0 Image 3: Example of Module and Ballast Graphical Representation 0 0 0 2 1 52.47 27.36 1 0 0 0 0 0 52.47 0 38.26 38.26 0 38.26 38.26 28.18 28.18 0 28.18 28.18 0 0 38.26 28.18 0 0 0 00 38.26 28.18 28.18 00 38.26 0 38.26 0 Exposed Edge53.38 53.38 43.30 0 28.18 0 0 58.43 58.43 38.26 ecolibriumsolar.com Page 7 507 Richland Ave., Athens, OH 45701 740-249-1877 BALLAST REPORT R-111Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSUplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 psf sqft deg sqft lbf lbf lbf lbf psf sqft deg sqft lbf lbf lbf lbf psf sqft deg sqft lbf lbf lbf lbf DLFUz=Uplift design load using ASD combo #7 = dLF1*0.6 + WLFUz*0.6 -16.91 BWuz=ballast weight required to resist wind uplift= -DLFUz/0.6 28.18 Ala = PV Module Lift Area = Am * Cos (Θm):20.13 WLFUz=Uplift wind load force in Z direction=pUz*Ala -110.92 dLF1 = Dead load of one module and attributed hardware:57.53 DLFUz=Uplift design load using ASD combo #7 = dLF1*0.6 + WLFUz*0.6 -32.03 Θm = Module Incline: Am = Surface Area of Module: 20.40 Θm = Module Incline:9.27 Ala = PV Module Lift Area = Am * Cos (Θm):20.13 WLFUz=Uplift wind load force in Z direction=pUz*Ala -85.71 dLF1 = Dead load of one module and attributed hardware:57.53 BWuz=ballast weight required to resist wind uplift= -DLFUz/0.6 53.38 Interior Module GCn Value from RWDI report:-0.20 qh value from Table 3:20.87 pUz = Uplift design wind pressure in Z direction = qh*GCn:-4.26 9.27 BWuz=ballast weight required to resist wind uplift= -DLFUz/0.6 -0.31 20.87-6.5120.409.27 20.13 -131.0857.53-44.1373.55 WLFUz=Uplift wind load force in Z direction=pUz*Ala dLF1 = Dead load of one module and attributed hardware:DLFUz=Uplift design load using ASD combo #7 = dLF1*0.6 + WLFUz*0.6 East/West Edge ModuleGCn Value from RWDI report:-0.26 qh value from Table 3:20.87 pUz = Uplift design wind pressure in Z direction = qh*GCn:-5.51 Am = Surface Area of Module: 20.40 Detailed Calculations From Table 4 North Corner Module GCn Value from RWDI report: qh value from Table 3:pUz = Uplift design wind pressure in Z direction = qh*GCn:Am = Surface Area of Module: Θm = Module Incline: Ala = PV Module Lift Area = Am * Cos (Θm): ecolibriumsolar.com Page 8 507 Richland Ave., Athens, OH 45701 740-249-1877 Uplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 Ecolibrium Solar utilizes the unattached design approach to account for seismic force as provided for by Section 16 of the California Building Code (CBC) and the Structural Engineering Association of California PV1 Requirements (SEAOC PV1- 2012). Section 1613 of the CBC defines “Ballasted Photovoltaic System”. SEAOC PV1 defines conservative calculations to be used to design unattached photovoltaic systems, independent of friction considerations. The unattached approach begins with the project specific design criteria. Table 6 lists the relavent project inputs. SEAOC PV1 - 2012 - Section 5: Unattached Arrays Seismic Design Category B Table 6: Seismic Design InputsSite Class D Fa (Site Class D)1.6Ip1 IIOccupancy Category Sds = (2/3) x Sms 0.182Sms = Fa x Ss 0.274Fa (Site Class E)2.5 6 in.A, B, C Ie Seismic Design Category ΔMPV Table 7: SEAOC PV1 ΔMPV Definitions 1 SEAOC PV1 defines the value ΔMPV, which is the design seismic displacement of the array relative to the roof. This is defined in Table 7. According to SEAOC research, these values are more conservative than shake table testing. D, E, F [(SDS – 0.4)2] * 60 in. ≥ 6 in. For this project, the Seismic Design Category is evaluated as B, and so ΔMPV evaluates as 6 in. SEAOC PV1 Section 6 - Design of Unattached Arrays to Accommodate Seismic Displacement accommodates seismic events by providing calculations to determine the minimum separation required between arrays and roof features. In a seismic event, this minimum spacing ensures the ballasted solar system is allowed to move freely without damaging any roof features, or itself. The calculations outlined in SEAOC PV1 and results are shown in Table 8. Condition Calculation ResultTable 8: SEAOC PV1 Array Setback Requirement Calculations Between array and fixed object (Ip ) ΔMPV 6 in.Between arrays of similar construction 0.5(Ip)ΔMPV 3 in. Between array and roof edge with no parapet 1.5(Ie) ΔMPV 9 in. Between array and roof edge with parapet (Ie ) ΔMPV 6 in. ecolibriumsolar.com Page 16 507 Richland Ave., Athens, OH 45701 740-249-1877 BALLAST REPORT R-112Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSUplift, Sliding, & Seismic Calculations for the Proposed Project in Northampton, MA 01060 Once the minimum separation distances are defined, the maximum allowable array size is determined according to the calculations found in Section 6 pertaining to the interconnection strength of an array. Ultimately, the arrays must not break apart under the forces experienced during potential seismic events. The total horizontal force is defined in SEAOC PV1 as the larger of 0.133SDSW1 and 0.1W1, where W1 is "the weight of the portion of the array, including ballast, on the side of the section that has smaller weight." In practice, Ecolibrium Solar uses the SEAOC equations to calculate the maximum number of modules allowable in the north/south and east/west directions of a rectangular array. This is done by finding the maximum allowable W1 per module at the interconnection plane, based on the interconnection strengths listed in Table 9. As per SEAOC PV1 - 2012, the system as been determined to have a coefficient of friction greater than 0.4. The coefficients of friction is based on roof material, use of a slip sheet, wet or dry conditions, and expected ballast conditions. All friction values have been identified by Testing Engineers (IAS accredited) according to ASTM G115 - Standard Guide for Measuring and Reporting Friction Coefficients, methodology that is in agreement with SEAOC and Los Angeles, CA stipulations. Table 9: EcoFoot2+ Interconnection Strength E/W Horizontal Force 358 lbs.Module Design Strength N/S Horizontal Force 110 lbs. Force Direction Table 10: Maximum W1, and W1 side modules As the east/west and north/south interconnection strengths are known, the SEAOC equations are rearranged to use horizontal force to determine a maximum W1 for a given section. Then from the maximum sectional W1, the maximum allowable modules on the smaller side of an array is determined from the module and racking weights, as shown in Table 10. The maximum dimensions of any given array, or 2x the maximum W1 half of an array, is also listed in Table 10. These values are used as the maximum dimensions of any array for this particular project. Maximum Section W1 per Module Interconnection 1100 pounds East-West Calculations Maximum Section W1 per Module at Interconnection North-South Calculations Maximum Array E/W Width (Maximum Section Modules x 2)58 modules Maximum Section Modules from Maximum W1 29 modules 3580 pounds 16 modules Maximum Modules per Section per Module at Interconnection 8 modules Maximum Array N/S Depth (Maximum Section Modules x 2) ecolibriumsolar.com Page 17 507 Richland Ave., Athens, OH 45701 740-249-1877 BALLAST REPORT R-113Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/22/2021SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANS8LIEI-SQMIML )RTLEI-)RSERMRIVEI08)1IPP QSIQMRPISRPML-SQMRIV )SRSPMEIMRIVSRRIMSRIMTQIR MRSEMRPIIRPSVIERVIEQPMRIER SVEIMREPPEMSRTVSMMRESRMIR TVIMVISPMSRSVVIMIRMEPETTPMEMSR -SIVTSSVTSPIMRTMVMER )ESR6IVMIEVEIQP EI -SQMI -1 -1 8SPIEVRQSVIEFSX)RTLEWISIVMRKWMWMXIRTLEIS (EELII EI2IXSM 7QEVX -RGPHIW-5)RSSVGSQQRMGEXMSRERHGSRXVSP -RGPHIW08)1GIPPQSHIQMRGPHIHSRPMXL -5SQFMRIV)7 -RGPHIWWSPEVWLMIPHXSQEXGL)RWIQFPIIWXLIXMGWERHdeectheat PIMFPIRIXSVOMRKWTTSVXWMM )XLIVRIXSVGIPPPEV 3TXMSREP%VIGITXEGPIEEMPEFPISV40FVMHKI 4VSMHIWTVSHGXMSRQIXIVMRKERHGSRWQTXMSR QSRMXSVMRK 7MQTPI 6IHGIHWMIVSQ-5SQFMRIV-5%1IRXIVIHQSRXMRKFVEGOIXWWTTSVXWMRKPI WXHQSRXMRK 7TTSVXWFEGOERHWMHIGSRHMXIRXV 9TXSSVTSPIFVERGLGMVGMXWSV:% TPKMRFVIEOIVWRSXMRGPHIH %XSXEP4:SVWXSVEKIFVERGLGMVGMXW 6IPMEFPI •DurableNRTL-certiedNEMAtype3Renclosure MIIEVPMQMXIHEVVERX 8SIEVWPEFSVVIMQFVWIQIRXTVSKVEQGSIVEKI MRGPHIH 90PMWXIH -1 -18SPIEVRQSVIEFSX)RTLEWISIVMRKWMWMXIRTLEIS k)RTLEI)RIVPPVMLVIIVI)RTLEILI)RTLEIPSS-SQMRIV)ERSLIVVEIQEVSVIVMIREQIEVIVEIQEVS)RTLEI)RIV-R(EEISLERI -5SQFMRIV)7-5%1)7-5SQFMRIV)7MXL)RTLEWI-5)RSTVMRXIHGMVGMXFSEVHSVMRXIKVEXIHVIIRIKVEHI4:TVSHGXMSRQIXIVMRK%27-ERHGSRWQTXMSRQSRMXSVMRK-RGPHIWEWMPIVsolarshieldtomatchtheEnchargestoragesystemandEnpowersmartswitchandtodeectheat. -5SQFMRIV)7-5%1)7-5SQFMRIV)7MXL)RTLEWI-5)RSTVMRXIHGMVGMXFSEVHSVMRXIKVEXIHVIIRIKVEHI4:TVSHGXMSRQIXIVMRK%27-ERHGSRWQTXMSRQSRMXSVMRK-RGPHIW)RTLEWI1SFMPISRRIGX08)1)0013()11ETPKERHTPEMRHWXVMEPKVEHIGIPPQSHIQSVWWXIQWTXSQMGVSMRIVXIVW%EMPEFPIMRXLI97EREHE1IMGS4IVXS6MGSERHXLI97:MVKMR-WPERHWLIVIXLIVIMWEHIUEXIGIPPPEVWIVMGIMRXLIMRWXEPPEXMSREVIE-RGPHIWEWMPIVWSPEVshieldtomatchtheEnchargestoragesystemandEnpowersmartswitchandtodeectheat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utdoor,NRTL-certied,NEMAtype3R,polycarbonateconstruction MVIWMIW %XS%FVIEOIVMRTXWXS%+GSTTIVGSRHGXSVW%FVIEOIVFVERGLMRTXXS%+GSTTIVGSRHGXSVW1EMRPKGSQFMRIHSXTXXS%+GSTTIVGSRHGXSVW2IXVEPERHKVSRHXSGSTTIVGSRHGXSVW%PEWSPPSPSGEPGSHIVIUMVIQIRXWSVGSRHGXSVWMMRK %PXMXHI 8SQIXIVWIIX -RXIKVEXIHMM FKR IPPPEV )0013()11+FEWIH08)1GIPPPEVQSHIQMRGPHIHSRPMXL-5SQFMRIV)72SXIXLEXER)RTLEWI1SFMPISRRIGXGIPPPEVQSHIQMWVIUMVIHSVEPP)RWIQFPIMRWXEPPEXMSRW )XLIVRIX 3TXMSREPEX)SVEX984)XLIVRIXGEFPIRSXMRGPHIH SQTPMERGISQFMRIV 90%27%2S64EVXPEWW-)74VSHGXMSRQIXIVMRK%27-EGGVEGGPEWW4:TVSHGXMSRSRWQTXMSRQIXIVMRKEGGVEGGPEWW SQTPMERGI-5)RS90%27%2S EI-SQMI AC COMBINER CUT SHEET R-114Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/22/2021SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy-duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general-duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-115Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.600Cohen, Michael44 Ward AveNorthampton, MA 0106009/23/2021SUBMIT FOR PERMIT