Stamped Plans_Gilleman Sarah_Rev BCOVER SHEET
SCOPE OF WORK GENERAL NOTES
REV NAME DATE COMMENTS
A
AC
AFCI
AZIM
COMP
DC
(E)
ESS
EXT
INT
MAG
MSP
(N)
NTS
OC
PRE-FAB
PSF
PV
RSD
TL
TYP
V
W
AMPERE
ALTERNATING CURRENT
ARC FAULT CIRCUIT INTERRUPTER
AZIMUTH
COMPOSITION
DIRECT CURRENT
EXISTING
ENERGY STORAGE SYSTEM
EXTERIOR
INTERIOR
MAGNETIC
MAIN SERVICE PANEL
NEW
NOT TO SCALE
ON CENTER
PRE-FABRICATED
POUNDS PER SQUARE FOOT
PHOTOVOLTAIC
RAPID SHUTDOWN DEVICE
TRANSFORMERLESS
TYPICAL
VOLTS
WATTS
PAGE
REV: B 8/13/2021
734 FOREST STREET #400, MARLBOROUGH, MA 01752
PHONE 888.657.6527
FAX 805.528.9701
SARAH GILLEMAN
40 SPRING ST, NORTHAMPTON,
MA, 01062
PROJECT NUMBER:
221R-040GILL
SHEET
DESIGNER:
BRIAN CALDERON
CUSTOMER RESIDENCE:
TEL. (413) 218-3435
APN: NHAM-000022B-000057-000001
#180120
(415) 580-6920 ex3
TABLE OF CONTENTS
PAGE #DESCRIPTION
PV-1.0 COVER SHEET
PV-2.0 SITE PLAN
PV-3.0 LAYOUT
PV-4.0 ELECTRICAL
PV-5.0 SIGNAGE
PV-1.0
LEGEND AND ABBREVIATIONS
SCALE: NTS
MAIN PANEL
INVERTER(S)
AC DISCONNECT(S)
DC DISCONNECT(S)
PV LOAD CENTER
SUB-PANEL
CB
ATTIC VENT
FLUSH ATTIC VENT
PVC PIPE VENT
SATELLITE DISH
T-VENT
CHIMNEY
FIRE SETBACKS
SUNRUN METER
METAL PIPE VENT
DEDICATED PV METER
SERVICE ENTRANCE
IQ COMBINER BOX HARDSCAPE
PROPERTY LINEINTERIOR EQUIPMENT
SHOWN AS DASHED
PL
SOLAR MODULES
SNR MOUNT & SKIRT
SNR MOUNT
MP
SP
SM
PM
INV
AC
DC
LC
SE
VICINITY MAP
• SYSTEM SIZE: 5760W DC, 6000W AC
• MODULES: (16) TRINA SOLAR: TSM-360DE06X.05(II)
• INVERTERS: (1) SOLAREDGE TECHNOLOGIES:
SE6000H-USS3
• RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL
TRACK ON COMP, SEE DETAIL SNR-DC-00436
• ENERGY STORAGE SYSTEM: (1) LG CHEM: RESU 10H
• SERVICE ENTRANCE CONDUCTORS TO BE REPLACED.
#SSTAMPCS
#ESTAMPCS
• ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC),
MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION
INSTRUCTIONS.
• PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
• ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
• PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY
GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35.
• MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
• INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
• SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II
MODULES, ARE CLASS A FIRE RATED.
• RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
• CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
• ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
• 10.3 AMPS MODULE SHORT CIRCUIT CURRENT.
• 16.09 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)].
• PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
• ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540.
• ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING
ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH NEC 706.30
AND EXCEPTION 1 NEC 706.30 (A).
• ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE ENERGY
STORAGE DEVICE INPUT AND OUTPUT TERMINALS ARE MORE THAN 5 FT FROM
CONNECTED EQUIPMENT, OR WHERE THE CIRCUITS FROM THESE TERMINALS
PASS THROUGH A WALL OR PARTITION PER 706.7(E).
• LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP
CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY
ADDITIONAL OUTLETS OR DEVICES PER NEC 210.12(D).
• THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR
GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION
EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A)
• ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8
PL
PL
PL
PL
PL
PL
P
L
P
L
P
L
P
L PLPL
PL PLPLPLP
L
P
L
P
L
PAGE
REV: B 8/13/2021
734 FOREST STREET #400, MARLBOROUGH, MA 01752
PHONE 888.657.6527
FAX 805.528.9701
SARAH GILLEMAN
40 SPRING ST, NORTHAMPTON,
MA, 01062
PROJECT NUMBER:
221R-040GILL
SHEET
DESIGNER:
BRIAN CALDERON
CUSTOMER RESIDENCE:
TEL. (413) 218-3435
APN: NHAM-000022B-000057-000001
#180120
(415) 580-6920 ex3
SITE PLAN
ARRAY
PITCH
PV AREA
(SQFT)
AR-01 32°158.8
AR-02 32°99.3
AR-03 26°59.6136°150°
316°
TRUE
AZIM
MAG
AZIM
150°136°
330°
PV-2.0
#SSTAMPSP #ESTAMPSP
SITE PLAN - SCALE = 1/16" = 1'
BPBI
(N) ARRAY AR-01
MP
(N) ARRAY AR-02
(E) GATE
(E) DETACHED
STRUCTURE
(E) DRIVEWAY
S
PR
I
NG
S
T
PM
DC
SE AC INV
(N) ARRAY AR-03
PAGE
REV: B 8/13/2021
734 FOREST STREET #400, MARLBOROUGH, MA 01752
PHONE 888.657.6527
FAX 805.528.9701
SARAH GILLEMAN
40 SPRING ST, NORTHAMPTON,
MA, 01062
PROJECT NUMBER:
221R-040GILL
SHEET
DESIGNER:
BRIAN CALDERON
CUSTOMER RESIDENCE:
TEL. (413) 218-3435
APN: NHAM-000022B-000057-000001
#180120
(415) 580-6920 ex3
PV-3.0
LAYOUT
#SSTAMP
STRUCTURAL NOTES:
·INSTALLERS SHALL NOTIFY
ENGINEER OF ANY
POTENTIAL STRUCTURAL
ISSUES OBSERVED PRIOR
TO PROCEEDING W/
INSTALLATION.
·IF ARRAY (EXCLUDING
SKIRT) IS WITHIN 12"
BOUNDARY REGION OF ANY
ROOF PLANE EDGES
(EXCEPT VALLEYS), THEN
ATTACHMENTS NEED TO BE
ADDED AND OVERHANG
REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS
FOLLOWS:
··ALLOWABLE ATTACHMENT
SPACING INDICATED ON
PLANS TO BE REDUCED BY
50%
··ALLOWABLE OVERHANG
INDICATED ON PLANS TO
BE 1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION
Name Type Height Type Max
Span
OC
Spacing Detail Max Landscape
OC Spacing
Max Landscape
Overhang
Max Portrait
OC Spacing
Max Portrait
Overhang Configuration
AR-01 COMP SHINGLE - RLU 2-Story TRUE CUT 2X4 RAFTERS 8' - 3"24"RL UNIVERSAL, SPEEDSEAL TRACK ON
COMP, SEE DETAIL SNR-DC-00436 6' - 0"2' - 4"4' - 0"1' - 11"STAGGERED
AR-02 COMP SHINGLE - RLU 2-Story TRUE CUT 2X4 RAFTERS 8' - 3"24"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE
DETAIL SNR-DC-00436 6' - 0"2' - 4"4' - 0"1' - 11"STAGGERED
AR-03 COMP SHINGLE - RLU 2-Story 2X6 RAFTERS 8' - 1"24"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE
DETAIL SNR-DC-00436 6' - 0"2' - 4"4' - 0"1' - 8"STAGGERED
DESIGN CRITERIA
MAX DISTRIBUTED LOAD: 3 PSF
SNOW LOAD: 40 PSF
WIND SPEED:
117 MPH 3-SEC GUST.
S.S. LAG SCREWS:
5/16"X4.5": 2.5" MIN EMBEDMENT
D1 - AR-01 - SCALE: 3/16" = 1'-0"
PITCH: 32°
AZIM: 136°
D3 - AR-03 - SCALE: 3/16" = 1'-0"
PITCH: 26°
AZIM: 136°
D2 - AR-02 - SCALE: 3/16" = 1'-0"
PITCH: 32°
AZIM: 316°
1'-8"22'-4"3'-6"
1'-7"
6'-7"
2'-4"
1'-8"16'-9"9'-1"
1'-9"
6'-7"
2'-1"
2'-10"16'-9"5'-1"
1'-6"
3'-3"
3'-11"
6'TYP
6'TYP
6'TYP
JUNCTION BOX
MIN RATED NEMA3R
SQUARE D
HU361RB
3R, 30A, 600VDC
(N) HEAVY DUTY
SAFETY SWITCH
+-
(1) ENERGY STORAGE SYSTEM
LG ENERGY SOLUTION: RESU 10H
PRIME
3
1
3
2
4
PV MODULES
TRINA SOLAR: TSM-360DE06X.05(II)
(16) MODULES
OPTIMIZERS WIRED IN:
(1) SERIES OF (8) OPTIMIZERS
(1) SERIES OF (8) OPTIMIZERS
SOLAREDGE POWER OPTIMIZERS
P370
LOAD RATED DC DISCONNECT,
AFCI, REVENUE GRADE METER,
RAPID SHUTDOWN AND ENERGY
STORAGE SYSTEM INPUTS
SOLAREDGE TECHNOLOGIES:
SE6000H-US WITH REVENUE
GRADE METERING (PN
SE6000H-USS3), 6000 WATT
INVERTER
6000 WATT INVERTER
BATTERY
SOLAR
2
3
5
M
240V METER SOCKET
100A CONTINUOUS
(N) MA SMART
UTILITY
REVENUE
METER
UTILITY SIDE OF CIRCUIT
CONNECTS TO TOP LUGS -
(LINE AT TOP LOAD AT BOTTOM)
(N) 125A
BACKUP
LOADS PANEL
FACILITY
LOADS
(N) 50A
FEEDER
BREAKER
(N) CURRENT
TRANSFORMERS
1
(1) 40A
BREAKER
(N) SOLAREDGE
BACKUP INTERFACE
BI-NUSGN-01
M 1
200A
MICROGRID
INTERCON.
DEVICE
CTRL 25
(N) LOCKABLE
BLADE TYPE
AC DISCONNECT
SQUARE D
DU222RB
3R, 60A,2P
120/240VAC
44
3
FACILITY
GROUND
(N) 50 FEEDER BREAKER
AT OPPOSITE END OF
BUSBAR
EXISTING
100A MAIN
BREAKER
(END FED)
EXISTING
125A
MAIN
PANEL
FACILITY
LOADS
M
METER #:
NATIONAL GRID 91836129
120/240 VAC
SINGLE PHASE
SERVICE
UTILITY
GRID
NOTE: TOTAL PV BACKFEED = 31A
USED FOR INTERCONNECTION
CALCULATIONS
NEW 100A
SERVICE
DISCONNECT
CONDUIT SCHEDULE
#CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER
2 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2
3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2
4 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2
5 1" EMT OR EQUIV.(2) 4 AWG THHN/THWN-2 (1) 4 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2
PAGE
REV: B 8/13/2021
734 FOREST STREET #400, MARLBOROUGH, MA 01752
PHONE 888.657.6527
FAX 805.528.9701
SARAH GILLEMAN
40 SPRING ST, NORTHAMPTON,
MA, 01062
PROJECT NUMBER:
221R-040GILL
SHEET
DESIGNER:
BRIAN CALDERON
CUSTOMER RESIDENCE:
TEL. (413) 218-3435
APN: NHAM-000022B-000057-000001
#180120
(415) 580-6920 ex3
PV-4.0
ELECTRICAL
#ESTAMP
MODULE CHARACTERISTICS
TRINA SOLAR: TSM-360DE06X.05(II):
OPEN CIRCUIT VOLTAGE:
MAX POWER VOLTAGE:
SHORT CIRCUIT CURRENT:
360 W
44.8 V
37 V
10.3 A
PAGE
REV: B 8/13/2021
734 FOREST STREET #400, MARLBOROUGH, MA 01752
PHONE 888.657.6527
FAX 805.528.9701
SARAH GILLEMAN
40 SPRING ST, NORTHAMPTON,
MA, 01062
PROJECT NUMBER:
221R-040GILL
SHEET
DESIGNER:
BRIAN CALDERON
CUSTOMER RESIDENCE:
TEL. (413) 218-3435
APN: NHAM-000022B-000057-000001
#180120
(415) 580-6920 ex3
SIGNAGE
PV-5.0
#ESTAMP
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
25.00 AMPS
240 VAC
LABEL LOCATION:
AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION.
PER CODE(S): NEC 2020: 690.54
PV SYSTEM DISCONNECT
WARNING!
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
POWER SOURCE OUTPUT CONNECTION
LABEL LOCATION:
ADJACENT TO PV BREAKER AND ESS
OCPD (IF APPLICABLE).
PER CODE(S): NEC 2020:
705.12(B)(3)(2)
NOTES AND SPECIFICATIONS:
·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR
IF REQUESTED BY THE LOCAL AHJ.
·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
WORDS, COLORS AND SYMBOLS.
·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
METHOD AND SHALL NOT BE HAND WRITTEN.
·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
INVOLVED.
·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY
SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.
·DO NOT COVER EXISTING MANUFACTURER LABELS.
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
TURN RAPID SHUTDOWN
SWITCH TO THE "OFF"
POSITION TO SHUT DOWN
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY.
LABEL LOCATION:
ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED.
PER CODE(S): NEC 2020: 690.56(C)
4"
3"
ELECTRICAL SHOCK HAZARD
WARNING
TERMINALS ON LINE AND LOAD
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
LABEL LOCATION:
INVERTER(S), AC DISCONNECT(S), AC
COMBINER PANEL (IF APPLICABLE).
PER CODE(S): NEC 2020: 690.13(B)
!INVERTER 1
PHOTOVOLTAIC DC DISCONNECT
MAXIMUM SYSTEM VOLTAGE:VDC480
LABEL LOCATION:
INVERTER(S), DC DISCONNECT(S).
PER CODE(S): NEC 2020: 690.53
CAUTION:
40 SPRING ST, NORTHAMPTON, MA, 01062
PER CODE(S): NEC 2020: 705.10, 710.10
MULTIPLE SOURCES OF POWER
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING: PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION:
INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN, ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S): NEC 2020: 690.31(D)(2), IFC 2012:
605.11.1.4
WARNING!
SOURCES: UTILITY GRID,
BATTERY AND PV SOLAR
ELECTRIC SYSTEM
THREE POWER SUPPLY
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S): NEC 2020: 705.12(C),
706.11(A), & 706.11(B)
LABEL LOCATION:
INSTALLED WITHIN 3' OF RAPID SHUT DOWN
SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), IFC
2012: 605.11.1, IFC 2018: 1204.5.3
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
!
DO NOT ADD LOADS
PHOTOVOLTAIC SYSTEM
COMBINER PANEL
WARNING
LABEL LOCATION:
PHOTOVOLTAIC AC COMBINER (IF
APPLICABLE).
PER CODE(S): NEC 2020: 705.12(D)(2)(3)(c)
SERVICE ENTRANCE
PV PRODUCTION
METER(EXT)
AC DISCONNECT(EXT)
INVERTER(EXT)
DC DISCONNECT(INT)
ENERGY STORAGE(INT)
MAIN PANEL PV BREAKER
DISCONNECT(INT)
SOLAR PANELS ON ROOF