Loading...
Enpower-DS-EN-US (4)The Enphase Enpower™ smart switch connects the home to grid power, the Encharge storage system, and solar PV. It provides microgrid interconnection device (MID) functionality by automatically detecting and seamlessly transitioning the home energy system from grid power to backup power in the event of a grid failure. It consolidates interconnection equipment into a single enclosure and streamlines grid independent capabilities of PV and storage installations by providing a consistent, pre-wired solution for residential applications. Enphase Enpower To learn more about Enphase offerings, visit enphase.com Data SheetEnphase Ensemble energy management system Reliable • Durable NEMA type 3R enclosure • Ten-year limited warranty Smart • Controls safe connectivity to the grid • Automatically detects grid outages • Provides seamless transition to backup Simple • Connects to the load or service equipment¹ side of the main load panel • Centered mounting brackets support single stud mounting • Supports conduit entry from the bottom, bottom left side, and bottom right side • Supports whole home and partial home backup and subpanel backup • Up to 200A main breaker support • Includes neutral-forming transformer for split phase 120/240V backup operation 1. Enpower is not suitable for use as service equipment in Canada. To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enpower, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2021-01-25 MODEL NUMBER EP200G101-M240US00 Enphase Enpower smart switch with neutral-forming transformer (NFT), Microgrid Interconnect Device (MID), breakers, and screws. Streamlines grid-independent capabilities of PV and storage installations. ACCESSORIES and REPLACEMENT PARTS XA-E3-PCBA-ENS Replacement Enpower controller printed circuit board EP200G-NA-HD-200A Eaton type BR circuit breaker hold-down screw kit, BRHDK125 EP200G-HNDL-R1 Enpower installation handle kit (order separately) Circuit breakers (as needed)2, 3 BRK-100A-2P-240V BRK-125A-2P-240V BRK-150A-2P-240V BRK-175A-2P-240V BRK-200A-2P-240V BRK-20A-2P-240V-B BRK-30A-2P-240V BRK-40A-2P-240V BRK-60A-2P-240V BRK-80A-2P-240V Not included, must order separately: • Main breaker, 2 pole, 100A, 25kAIC, CSR2100 • Main breaker, 2 pole, 125A, 25kAIC, CSR2125N • Main breaker, 2 pole, 150A, 25kAIC, CSR2150N • Main breaker, 2 pole, 175A, 25kAIC, CSR2175N • Main breaker, 2 pole, 200A, 25kAIC, CSR2200N • Circuit breaker, 2 pole, 20A, 10kAIC, BR220B • Circuit breaker, 2 pole, 30A, 10kAIC, BR230B • Circuit breaker, 2 pole, 40A, 10kAIC, BR240B • Circuit breaker, 2 pole, 60A, 10kAIC, BR260 • Circuit breaker, 2 pole, 80A, 10kAIC, BR280 ELECTRICAL SPECIFICATIONS Assembly rating Continuous operation at 100% of its rating Nominal voltage / range (L-L)240 VAC / 100 - 310 VAC Voltage measurement accuracy ±1% V nominal (±1.2V L-N and ±2.4V L-L) Auxiliary contact for load control and excess PV control 24V, 1A Nominal frequency / range 60 Hz / 56 - 63 Hz Frequency measurement accuracy ±0.1 Hz Maximum continuous current rating 160A Maximum input overcurrent protection device 200A Maximum output overcurrent protection device 200A Maximum overcurrent protection device rating for storage branch circuit4 80A Maximum overcurrent protection device rating for PV combiner branch circuit4 80A Neutral Forming Transformer (NFT)• Breaker rating (pre-installed): 40A between L1 and Neutral; 40A between L2 and Neutral • Continuous rated power: 3600VA • Maximum continuous unbalance current: 30A @ 120V • Peak rated power: 8800VA for 30 seconds • Peak unbalanced current: 80A @ 120V for 30 seconds MECHANICAL DATA Dimensions (WxHxD)50cm x 91.6cm x 24.6cm (19.7 in x 36 in x 9.7 in) Weight 38.5 kg (85 lbs) Ambient temperature range -40º C to +50º C (-40º F to 122º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NEMA type 3R, polycarbonate construction Altitude To 2500 meters (8200 feet) WIRE SIZES Connections (All lugs are rated to 90C) • Main lugs and backup load lugs • CSR breakers • BR breakers (wire provided) • AC combiner lugs, Encharge lugs, and generator lugs • Neutral (large lugs) Cu/Al: 1 AWG – 300 KCMIL Cu/Al: 2 AWG – 300 KCMIL 6 AWG 14 AWG – 2 AWG Cu/Al: 6 AWG - 300 KCMIL Neutral and ground bars Large holes (5/16-24 UNF) Small holes (10-32 UNF) 14 AWG – 1/0 AWG 14 AWG – 6 AWG COMPLIANCE Compliance UL 1741, UL 1741 SA, UL 1741 PCS, UL1998, UL869A5, UL675, UL5085, UL50E5 CSA 22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003, AC156. 2. Compatible with BRHDK125 Hold-Down Kit to comply with 2017 NEC 710.15E for back-fed circuit breakers.3. The Enpower is rated 22 kAIC4. Not included. Installer must provide properly rated breaker per circuit breaker list above.5. Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. Enphase Enpower