Emily Wojick ELEC Plans UpdatedCOMPANY INFORMATION
CLIENT INFORMATION
SYSTEM DETAILS
PROJECT-PAGE TITLE
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
PAGE NUMBER
A
REVISIONS
LAST: 08/31/21 AH
AZIMUTH
ACCOUNT: 76397-21017
PREMISE: N/A
METER: 83004954
SITE MAP
N
EMILY WOJCIK
26 LONGFELLOW DR
NORTHAMPTON, MA 01062
PO 37349
NOTES:
1. (20) ENPHASE IQ7+
INVERTER(S) = 5.8kW AC
2. ARRAY 1:
270° AZIMUTH, 42° TILT
(20) LG 335W = 6.7kW
3. ARRAY 2:
(Array 2 Azimuth)° AZIMUTH,
(Array 2 Tilt)° TILT
((Array 2 Panel Qty)) LG 335W =
(Array 2 kW)kW
4. ARRAY 3:
(Array 3 Azimuth)° AZIMUTH,
(Array 3 Tilt)° TILT
((Array 3 Panel Qty)) LG 335W =
(Array 3 kW)kW
5. ARRAY 4:
(Array 4 Azimuth)° AZIMUTH,
(Array 4 Tilt)° TILT
((Array 4 Panel Qty)) LG 335W =
(Array 4 kW)kW
NOTES:
1. LOCATION OF SERVICE PANEL AND ELECTRICAL
EQUIPMENT ARE SHOWN. FINAL LOCATION MAY
CHANGE
2. LOCATION OF SERVICE PANEL AND ADDITIONAL
ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE
3. PV INTERCONNECTION IS A SECONDARY
INTERCONNECTION
4. AC DISCONNECT AND UTILITY REVENUE METER IN
READILY ACCESSIBLE LOCATION WITHIN 10' OF MAIN
SERVICE METER/UTILITY METER. 24/7 UNESCORTED
KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC
DISCONNECT, UTILITY REVENUE METER, & UTILITY
METER.
5. PV EQUIPMENT SHALL BE INSTALLED IN
ACCORDANCE WITH NEC 690 AND POSTED WITH
APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES
PER NEC 705-10, 690-17, & 690-64 (b)(5).
6. CIRCUITS:
(1) CIRCUIT(S) OF 10 (20AMPS EACH)
(1) CIRCUIT(S) OF 9 (15AMPS EACH)
(1) CIRCUIT(S) OF 1 (15AMPS EACH)
((Qty of circuits with the number of inverters optimizers
above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a
circuit/string) ([Amps] (If Enphase. Based on 15 or 20A
breakers)AMPS EACH)
((Qty of circuits with the number of inverters optimizers
above)) CIRCUIT(S) OF (Qty of inverters/optimizers in a
circuit/string) ([Amps] (If Enphase. Based on 15 or 20A
breakers)AMPS EACH)
1 2
34
5
6
LABELS LOCATED ON UTILITY REVENUE METER, UTILITY
METER, AC DISCONNECT(S), INVERTER(S), AND APPROPRIATE
LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE
PERMANENT, WEATHERPROOF, AND DURABLE
THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD
POWERLINES.
10
7
8<10'LONGFELLOW DRARRAY 1
9
11 12
CALL-OUTS:
1: SOLAR PANELS
2: INVERTERS
3: ENPHASE IQ COMBINER PANEL
4: UTILITY REVENUE METER
5: UTILITY PV AC DISCONNECT
6: UTILITY ESS AC DISCONNECT
7: AUTOMATIC TRANSFER SWITCH
8: HEAVY LOAD PANEL
9: UTILITY METER
10: MAIN LOAD PANEL
11: ESS AC DISCONNECT
12: ENERGY STORAGE SYSTEM
DISTANCESSOLAR PANELS - INVERTERS: 5' MAX
INVERTERS - IQ COMBINER PANEL: 50' MAX
IQ COMBINER PANEL - UTILITY REVENUE METER: 2'
UTILITY REVENUE METER - UTILITY PV AC DISCONNECT: 2'
UTILITY PV AC DISCONNECT - UTILITY ESS AC DISCONNECT: 2'
UTILITY ESS AC DISCONNECT - HEAVY LOAD PANEL: 2'
HEAVY LOAD PANEL - AUTOMATIC TRANSFER SWITCH: 2'
AUTOMATIC TRANSFER SWITCH - UTILITY METER: 2'
UTILITY METER - MAIN LOAD PANEL: 5'
MAIN LOAD PANEL - ESS AC DISCONNECT: 2'
ESS AC DISCONNECT - ENERGY STORAGE SYSTEM: 2'
COMPANY INFORMATION
CLIENT INFORMATION
SYSTEM DETAILS
PROJECT-PAGE TITLE
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
PAGE NUMBER
A
REVISIONS
LAST: 08/31/21 AH
NOTES:
1. DESIGN MEETS NEC CODE
AND SHALL BE INSTALLED IN
ACCORDANCE WITH NEC 690
AND POSTED WITH APPLICABLE
WARNINGS, SIGNAGE, AND
PLAQUES PER NEC 705-10, 690-
17, & 690-64 (b) (5)
2. SOLAR MODULES, INVERTERS,
AND CORRESPONDING
ELECTRICAL EQUIPMENT ARE
LISTED.
3. INVERTERS ARE UL 1741
LISTED
4. PV INTERCONNECTION IS A
SECONDARY INTERCONNECTION
SYSTEM SIZE: 6.7kW DC
MAXIMUM POWER: 5.8 kW AC
OPERATING VOLTAGE: 120/240V
MAXIMUM CURRENT: 24.2A
ACCOUNT: 76397-21017
PREMISE: N/A
METER: 83004954
*DISTANCES NOT TO SCALE*DISTANCES NOT TO SCALE
ELECTRICAL
LINE DIAGRAM
EMILY WOJCIK
26 LONGFELLOW DR
NORTHAMPTON, MA 01062
PO 37349
TO UTILITY
UTILITY REVENUE METER
(MA SMART)
120/240V, 100A WITH
BYPASS
1-PHASE, 3-WIRE
SEE LABEL(S) 21 ON
FOLLOWING PAGES
LINE
LOAD
AC
DC
5' MAX
[1 OF 2]
UTILITY PV
AC DISCONNECT
VISIBLE-OPEN TYPE, LOCKABLE,
READILY ACCESSIBLE
1 PHASE, 60A, 120/240V
SEE LABEL(S) 10, 14, 15, 16, 20, 35a
ON FOLLOWING PAGES
Round Trip
Efficiency: >96%
10.5kWh Storage
AC
DC
[2 OF 2]
UTILITY ESS
AC DISCONNECT
VISIBLE-OPEN TYPE, LOCKABLE,
READILY ACCESSIBLE
1 PHASE, 30A, 120/240V
SEE LABEL(S) 14, 19, 91b
ON FOLLOWING PAGES
5' MAX 3/4" EMT:
(2) #10 THWN
(1) #10 NEUTRAL
(1) #10 GROUND
5' MAX 3/4" EMT:
(2) #10 THWN
(1) #10 NEUTRAL
(1) #10 GROUND
(19) LG
335N1K-V5
6.365kW
75' MAX 3/4" EMT:
(4) #10 THWN
(1) #10 GROUND
2' MAX 3/4" EMT:
(2) #8 THWN
(1) #10 NEUTRAL
(1) #10 GROUND
ENPHASE IQ COMBINER PANEL
120/240V 125A 1 PHASE
PLACARD INDICATING
"NO LOAD TO BE SERVED"
SEE LABEL(S) 16, 18, 24
ON FOLLOWING PAGES
2' MAX 3/4" EMT:
(2) #8 THWN
(1) #8 NEUTRAL
(1) #10 GROUND
120/240V
200A RATED BUS
200A
MAIN
[EXISTING]
MAIN LOAD PANEL
SEE LABEL(S) 18
ON FOLLOWING PAGES
NATIONAL GRID
UTILITY METER
120/240V, 1-PHASE, 3-WIRE
SEE LABEL(S) 41, 42
ON FOLLOWING PAGES
ENPHASE ENPOWER
SMART SWITCH
SEE LABEL(S) 18
ON FOLLOWING PAGES
MICROGRID
INTERCONNECT
DEVICE
100A
MAIN
[NEW]
HEAVY LOAD PANEL
SEE LABEL(S) 18
ON FOLLOWING PAGES
[Break
er Am
ps for
Backu
p Gate
way]A 2' MAX 2" PVC:
(2) #4/0 AL
(1) #2/0 AL N
(1) #6 GROUND
2': 1" PVC
(2) #3 THWN
(1) #3 NEUTRAL
2' EXISTING
CONDUIT
40A
30A
ESS
AC DISCONNECT
1 PHASE, 30A, 120/240V
SEE LABEL(S) 14
ON FOLLOWING PAGES
2' MAX 3/4" EMT:
(2) #10 THWN
(1) #10 NEUTRAL
(1) #10 GROUND
5' MAX
(1) ENPHASE
IQ7+
120/240V
(1) CIRCUIT(S) OF 1 (15A EA)
((Qty of circuits with the number
of inverters optimizers above))
CIRCUIT(S) OF (Qty of
inverters/optimizers in a
circuit/string) ([Amps] (If
Enphase. Based on 15 or 20A
breakers)A EA)
((Qty of circuits with the number
of inverters optimizers above))
CIRCUIT(S) OF (Qty of
inverters/optimizers in a
circuit/string) ([Amps] (If
Enphase. Based on 15 or 20A
breakers)A EA)
PV SHEDDING
RELAY
AC
DC
75' MAX 3/4" EMT:
(2) #10 THWN
(1) #10 GROUND
15A
SOLAR THAT PASSES THROUGH
RELAY BOX WILL SHUT DOWN
DURING GRID OUTAGE
LINETAP VIA UL-LISTED
POLARIS LUGS
(1) LG
335N1K-V5
0.335kW
(19) ENPHASE
IQ7+
120/240V
(1) CIRCUIT(S) OF 10 (20A EA)
(1) CIRCUIT(S) OF 9 (15A EA)
(1) CIRCUIT(S) OF 1 (15A EA)
((Qty of circuits with the number
of inverters optimizers above))
CIRCUIT(S) OF (Qty of
inverters/optimizers in a
circuit/string) ([Amps] (If
Enphase. Based on 15 or 20A
breakers)A EA)
((Qty of circuits with the number
of inverters optimizers above))
CIRCUIT(S) OF (Qty of
inverters/optimizers in a
circuit/string) ([Amps] (If
Enphase. Based on 15 or 20A
breakers)A EA)
2' MAX 3/4" EMT:
(2) #10 THWN
(1) #10 GROUND
2' MAX 3/4" EMT:
(2) #8 THWN
(1) #8 NEUTRAL
(1) #10 GROUND
(1)
ENPHASE
ENCHARGE 10
(240V)
(LOCATED INSIDE)
COMPANY INFORMATION
CLIENT INFORMATION
SYSTEM DETAILS
PROJECT-PAGE TITLE
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
PAGE NUMBER
A
REVISIONS
LAST: 08/31/21 AH
EQUIPMENT
SPECIFICATIONS
EMILY WOJCIK
26 LONGFELLOW DR
NORTHAMPTON, MA 01062
PO 37349
ENERGY STORAGE SYSTEM IS DESIGNED WITH THE
CHARGING CAPABILITY OF GENERATION ONLY, AND
THE DISCHARGING CAPABILITY OF ONSITE LOADS
ONLY.
STORAGE SYSTEM DETAILS:
(1) ENPHASE ENCHARGE 10 AC (240V)
Total Energy: 10.5.kWh
Usable Energy: 10.08kWh
Real Power, max continuous: 1.28kW (charge & discharge)
Real Power, peak (10s): 1.92kW (discharge only)
Max Current: 16A
Internal DC Voltage 67.2V
Round Trip Efficiency: >89%
LG
335N1K-V5
RATED POWER
AT STC:335W
VMP:34.50V
IMP:9.72A
VOC:41.10V
ISC:10.31A
MODULE DETAILS:
(20)
INVERTER DETAILS:
ENPHASE IQ7PLUS-72-2-US
Rating: 290 W
CEC Weighted Efficiency: 97 %
Max DC Voltage: 60.V V
Max AC Output Current: 1.21 A
Nominal Voltage Range:
240V / 211-264V (1-Phase)
Nominal Frequency: 60 Hz
COMPANY INFORMATION
CLIENT INFORMATION
SYSTEM DETAILS
PROJECT-PAGE TITLE
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
PAGE NUMBER
A
REVISIONS
LAST: 08/31/21 AH
LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
MOUNTED, AND COMPLY WITH
NEC 690
ACCOUNT: 76397-21017
PREMISE: N/A
METER: 83004954
LABELS
EMILY WOJCIK
26 LONGFELLOW DR
NORTHAMPTON, MA 01062
PO 37349
INVERTER(S): N/A
AC DISCONNECT(S): 10, 16, 18
UTILITY AC
DISCONNECT: 10, 14, 15, 16, 20,
35
UTILITY REVENUE
METER: 21
MAIN ELECTRICAL SERVICE: 18
UTILITY METER: 41, 42
IQ COMBINER PANEL: 16, 18, 24
PHOTOVOLTAIC AC DISCONNECT
MAXIMUM AC OPERATING CURRENT:
NOMINAL OPERATING AC VOLTAGE:
P H O T O V O L T A I C
A C D I S C O N N E C T
MAIN PHOTOVOLTAIC
SYSTEM DISCONNECT
CAUTION: SOLAR ELECTRIC
SYSTEM CONNECTED
! WARNING DUAL POWER SOURCE
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
WARNING: PHOTOVOLTAIC
POWER SOURCE
WARNING!
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
16
13
15
41
42
14
5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT.
8:
10
HOUSE
METER
21
PV
PRODUCTION
METER
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
SOLAR ELECTRIC
PV PANELS
35
MAXIMUM DC VOLTAGE
OF PV SYSTEM
7
PHOTOVOLTAIC
DC DISCONNECT
6
!
POWER SOURCE OUTPUT CONNECTION. DO NOT
RELOCATE THIS OVERCURRENT DEVICE.
WARNING
PV SYSTEM CIRCUIT BREAKER IS BACKFED
CAUTION
36
37
UTILITY
AC DISCONNECT
20
NOTE: LABELS ARE FOR
GENERAL REFERENCE.
NOT ALL LABELS ARE USED
FOR EVERY INSTALLATION.
INTERCONNECTION
DISCONNECT SWITCH
17
COMPANY INFORMATION
CLIENT INFORMATION
SYSTEM DETAILS
PROJECT-PAGE TITLE
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
PAGE NUMBER
A
REVISIONS
LAST: 08/31/21 AH
LABELS 2
LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
MOUNTED, AND COMPLY WITH
NEC 690
ACCOUNT: 76397-21017
PREMISE: N/A
METER: 83004954
43
18
MAIN PV DISCONNECT
PV COMBINER PANEL
(INSIDE GARAGE)
MAIN ESS DISCONNECT
EMILY WOJCIK
26 LONGFELLOW DR
NORTHAMPTON, MA 01062
PO 37349
CAUTION:MULTIPLE SOURCES OF POWER:
N
All Energy Solar
www.allenergysolar.com
(800) 620-3370
SOLAR ARRAY
HOUSE SERVICE DISCONNECT
INTERCONNECTION
DISCONNECT SWITCH
17
DUAL POWER SOURCE
PHOTOVOLTAIC CIRCUIT
Operating Voltage: 120/240
Maximum Current: 24.2 Amps
Maximum Power: 5.8 KW
MAXIMUM VOLTAGE
MAXIMUM CIRCUIT CURRENT
MAX RATED OUTPUT CURRENT OF
THE CHARGE CONTROLLER
OR DC-TO-DC CONVERTER
(IF INSTALLED)
22
24
NOTICEPV COMBINER
PANEL ONLY
NO LOADS
EMERGENCY DISCONNECT
SERVICE DISCONNECT
15
INVERTER(S): N/A
AC DISCONNECT(S): 10, 16, 18
UTILITY AC
DISCONNECT: 10, 14, 15, 16, 20,
35
UTILITY REVENUE
METER: 21
MAIN ELECTRICAL SERVICE: 18
UTILITY METER: 41, 42
IQ COMBINER PANEL: 16, 18, 24
COMPANY INFORMATION
CLIENT INFORMATION
SYSTEM DETAILS
PROJECT-PAGE TITLE
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
PAGE NUMBER
A0
REVISIONS
LAST: 08/31/21 AH
LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
MOUNTED, AND COMPLY WITH
NEC 690
ACCOUNT: 76397-21017
PREMISE: N/A
METER: 83004954
LABELS (ESS)
EMILY WOJCIK
26 LONGFELLOW DR
NORTHAMPTON, MA 01062
PO 37349
-UTILITY PV AC DISCONNECT 1 OF 2-
BOTH UTILITY AC DISCONNECTS MUST BE OPEN IN
ORDER TO ISOLATE NON-UTILITY POWER SOURCES
-UTILITY ESS AC DISCONNECT 2 OF 2-
BOTH UTILITY AC DISCONNECTS MUST BE OPEN IN
ORDER TO ISOLATE NON-UTILITY POWER SOURCES
- ENERGY STORAGE SYSTEM WITH AUTOMATIC
TRANSFER SWITCH IS PRESENT
NOTE: LABELS ARE FOR
GENERAL REFERENCE.
NOT ALL LABELS ARE USED
FOR EVERY INSTALLATION.
ENERGY
STORAGE
SYSTEM
DISCONNECT
22
NOMINAL ESS AC VOLTAGE:
MAXIMUM ESS DC VOLTAGE:
AVAILABLE FAULT CURRENT
DERIVED FROM THE ESS
DATE CALCULATION PERFORMED
23:
26
NOTICEENERGY GENERATION
COMBINER PANEL ONLY
NO LOADS
27
NOTICETHIS PANEL SUPPLIED BY
UTILITY, SOLAR AND
BATTERY
Label 91a
Label 91b
Label 44
25
NOTICEPOWERWALL COMBINER
PANEL ONLY
NO LOADS
INVERTER(S): N/A
AC DISCONNECT(S): 10, 16, 18
UTILITY AC
DISCONNECT: 10, 14, 15, 16, 20,
35
UTILITY REVENUE
METER: 21
MAIN ELECTRICAL SERVICE: 18
UTILITY METER: 41, 42
IQ COMBINER PANEL: 16, 18, 24