Loading...
43-107 (3) 63 PARK HILLRD COMMONWEALTH OF MASSACHUSETTS BP-2021-1759 Map:Block:Lot:43-107-001 Permit: Solar Build CITY OF NORTHAMPTON PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2021-1759 PERMISSION IS HEREBY GRANTED TO: Project# Contractor: License: NORTHEAST SOLAR DESIGN Est. Cost: $32729 ASSOCIATES LLC 106113 Const.Class: Exp.Date:06/07/2023 Use Group: Owner: SYLVAN THOMAS M&ELIZABETH I Lot Size (sq.ft.) Zoning: WSP Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC Applicant Address Pon : Insurance: 136 ELM ST (413)247-6045 0 PK201900018166 HATFIELD, MA 01038 ISSUED ON:08/19/2021 TO PERFORM THE FOLLOWING WORK: INSTALL 28 PANEL 10.22 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: OH: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: t i . cfr't • Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner / ( va1n City of orth ptorAf/ >//'Sows of Permit Building•pe'l ent �' J v°,ktiub Cut)Uriwtway Penult 212 Main\ 6 Sepnc,watlablHtp Room 1t&'1‘./ c M'. Awallabf!ty , „ Northampton, MA` fi, ! Seat St►urt_,-a Plans phone 413-587.1240 Fax 41 +58 272 :' Plot►�d6.Plans __APPLICATION TO CONSTRUCT,ALTER,REPAIR, RE VATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION t 1 This section to be compk s.d by etas 63 Park Hill Rd Map Lot Unit Florence MA 01062 zoos Overlay Dtstrldt Elm St District CB Olabtet SECTION 2-PROPERTY OWN ERSHIP!AUTHORIZED AGENT 2.1 Owner of Record: 63 Park Hill Rd Thomas Sylvan Florence MA 01062 w rra(Prink; / _ Currerc ramie-el Address' 4_�� iglgptgre 413-475-2417 SKJnalure 22 Authori2ed Apnnt: North--• So,: 136 Elm St. Hatfield. MA 01038 V9rre(Print) Curren rtarinr,Address, .......... f 413-247-6045 Sigrulurn AI • 1l. ` Tdnphore tl .... - .,i - 4 o ,. . e 1. isl 1,•,.1'.0:- • Items Estimated Cost(Dollars}to be Official Use Only completed by permit applicant 1. Building iaF Building Permit Fee 2. Electrical (bb Estimated Total Cost of Construction from j6) 3. Plumbing Building Pontiff Fee 4476 4. Mechanical(HVAC} 5.Fire Pretecbce 6. Tote!=(1 *2*3 s•4*5) 532.729 Check Number _ a/4/ > TThle Section For Official Use Only Building Permit Number. .. i /Sy Data Issue& //g2 Hutdrrlg C4mnasyoner;lrspeaor ri auldrnr, Dale Section 4. ZONING All Information Must ee Compieeed, Permit...an 4r•Denied Due To Incomplete information Existing Proposed Required by Zoning This a+lumn to be blind in by Building Department Lot Sizc Frontage Setbacks Front ' t ��' L_J I V. Sure L: 1 R: LA---J II1:U [ k 11113 Rear I I Building Height Bldg. Square Footage *'e Open Space Footage S r r (LM ma vinus Mktg pa,LJ 1 of Parking Spaces - ._ fvoturac k Locacm; A. Has a Special Permit/Variance/Finding ever been °ssued for:on 1-c site? NO 0 DONT KNOW 0 YES i ) IF YES, date issued: F YES: Was the permit recorded at the Registry of Deeds? NIO 0 DONT KNOW YES C) IF YES: enter Book r Page a..dfor DucLme-t B. Does the site contati•H a brook, body of water or wetlands? NO () DONT KSCW YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: C. Do any signs exist c:7 the prob rty? YES (0 NO IF YES, describe size, type arid location: D. Are there any proposed changes to or additions of signs intended for he broocrty ? YES 0 NO 0 IF YES, describe size, type and tocation: E. 441II the construction activity disturb(ct .€�radtnt), cavatlon.or filling)over 1 acre or i s it pert of a common plan that will disturb over I acre? YES fWO IF YES.then a Northampton Storm Water Managernent Permit from the DPW is required. by .• , •!: • •. • is • .•:• • :i•: 'r New House Q Addition ❑ Replacement Windows Alteration(s) ❑ Roofing El Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs (DJ Decks IC slcting ire) Other(NI Bnef Description of Proposed Install 28 solar panels on Roof Watt: Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes __No Plans Attached Roll -Sheet ta.f Now house and or addition to adding hooting.co,AOislo ifs Movable a. Use of building:One Family Two Family_ Other b. Number of rooms in each family unit: Number of Bathrooms c_ Is there a garage attached? d. Proposed Square footage of new construction_ Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodatoves Nu mber of each g. Energy Conservation Compliance. Masacheck Energy Compliance form attached?_ h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building end Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City wager Supply SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLES FOR BUILDING PERMIT l Thomas Sylvan ,as Owner of the subject property hereby authorize Northeast Solar a my behalf,in MI ma relative to work authorized by this building permit application. < 5-Z/ -0/ 41111111/ Si ure Or Omer ask' 1, Gregory Garrison/Northeast Solar ,as Ownen'Aulhorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief_ Signed under the pains arid penalties of perjury. Gregory Garrison Print Name / . 1 (P111412 Siwwrurn CTwmriA ,act ,41 r SECTION 8-CONSTRUCTION SERVICES 0.1 Licensed Construction Supervisor: Not Applicable 0 Phi11_p 3aunsgard name of License Fielder .__ CS106113 License Number 41 Heath Rd Colrain, Ma 01340 6/7/23 ` ► / 413-247-6045 Telephone 9.Redlstered some IrMrcverent Ccnt-acto': Not Applicable 0 Northeast Solar 1E3641 Company Name Registrat or Number 136 Elm Hat r -1d Ma 01038 7/13/2023 Address Exo!ratrr Gate Telephone413-247-EC45 14, . SECTION 10-WOR OMPENSATION INSURANCE AFFIDAVIT(M.G.L c.152.§25C(6)) Workers Compensa:!on Ins.rance afflda'nt must be corroeted and submitted with this appl cater. Failure t_:prc•.+de this affidavit will result in the•:eniai of the esLarce of the building permit Signed.Af`ielavit Attached Yes....._.Xi No 0 11. — Home Owner Exemption The current exemption:or"homeowners"was extended to include Owner-occupied Dwellings of one(I) or :wo12) families and to allow such homeowner to engage an individual for hire who does no:possess a license,provided that the owner acts as rarer rigor.CNIR 780, Sixth Edition Section 148.3.11, Definition of Homeowner: Person(s)who own a parcel of land on which bcfsbc resides or intends to reside,on which there is,or is intended to be,a one or tan family dwelling,attached or detached structures accessory to such use and or farm structures.A person who constructs more than one home In a two-year period shall not be considered a homeowner. Such"homeowner"shall sLbr..:t:o the Building Official,on a form acceptable to the Building Official,that he,she shall b e responsible for all such work performed under the barb, As acting Constructioe5uperyisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,von may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and=sums responsibility for compliance with the State Building Co4e,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined++ by MGL c 111, S 150A. Address of the work: 03 Var �'L � o re,v. d The debris will be transported by: Po r-hu Cl cuj The debris will be received by: U._ 11 Building permit number: Name of Permit Applicant : 13° Da a ignature of Permit Appl. t The Common-wealth of Massachusetts Department of Industrial Accidents Office of Investigations 1 Congress Smet, Suite 100 Boston, MA 02114-2017 www.marss.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print L egibly Business/Organization Name: Northeast Solar Address:136 Elm St. City../StatelZip:Hattield, MO 010:38 Phone #:413-247-6045 Are you an employer? Check the app rop riate box: Business Type(requited): 1.0 I am a employer with 17 employees(full and! 5. ❑Retail or part-time).* 6. ❑RestaurantlBarVEatingEstablishmxit 2.❑ I am a sole proprietor or partnership and have no 7. ❑Office and/or S ales(incl. real estate, auto, etc.) employees working for m e in any capacity. [No workers' comp.insurance required] 8. ❑Non-profit 3.1=1 We are a corporation and its officers have ex ercised 9. ❑Entertairanent their right of exemption per c. 152,§1(4), and we have 10.❑A1lanufacturing no employees. [No workers'comp. insurance required]** 4.El '.Ve are a non-pr ofit or ganiz ati on, staffed by volunteers, 11.12Healthcare with no employees. [No workers' comp, insurance req.] 12.0 Other *Any applicant that cheers box#1 mist also fill cut the sectionbelow slowing their workers'compels ation policy information **If the curppTate officer;have erempted themselves,but the corporation has o$er employees,aworkers'cu ripe rationpolicy is nquued and such an oganimtion should cluck box#I. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Ina arance C ompany Name.New York Marine and General Insurance Company Ins-ixer'sAddress: 63 Park Hill Rd City/State/Zip: Florence MA 01062 Policy or S elf-ins,Lic. . #WC201900019843 Expir ation Date: 7/8/2022 Attach a copy of the workers' comp ensatio n p o licy declaration page (showing the p olicy number and exp iratio n date). Failure to secure coverage asrequiredunder Section25A of IVICIL c. 152 can lead to the imposition of criminal penalties of a fine lip to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of aSTOP WORE ORDER and a fine of yap to$250.00 a day against the violator. Be advised that a copy of this statement maybe forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certafy, under th. ;'ins ( perjury that the information provided above is true and corral. Sienattrre: D ate: 5/21/2021 Phone41:3-247-6047 - +,i Official use only. Do note _ area, to be completed by city or town official City or Town: Permit;License Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Licensing Board 5. Selectmen's Office 6. Other Contact Person: Phone/4: yr w.rriass govlaia ___...--.,N NORTSOL-01 JHOGAN ACORO CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDlYYYY) `-------- 7/9/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: EPIC Insurance Brokers&Consultants PHONE FAX 1aa Gould Street Suite 100 (A/C,1No,Ext►:(781)455-0700 I(NC,No):(781)449-8976 Needham,MA 02494 Am ass,certificates@roblininsurance.com INSURER(S)AFFORDING COVERAGE NAIC M INSURER A:Gotham Insurance Company INSURED INSURER B:Safety Insurance Company 39454 Northeast Solar Design Associates,LLC INSURER C:Capitol Indemnity Corporation 136 Elm Street INSURER D:New York Marine and General Insurance Company 16608 Hatfield,MA 01038 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBRI MD NUMBER M/POUCY EFF POUCY EXP LIMITS LTR INSD D IMDD/YYYYI IMMIDD/YYYYI A X COMMERCIAL GENERALUABIUTY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR PK201900018166 7/8/2021 7/8/2022 DAMAGE TO RENTED 300,000 PREMISES(Ea occurrence) _,S ' MED EXP(Any one person) I$ 5,000 I PERSONAL 8 ADV INJURY $ 1,000,000 GEM.AGGREGATE UMIT APPUES PER: GENERAL AGGREGATE $ 2'000'000 —I POUCY X PECT LOC PRODUCTS-COMP/OP AGO $ 2,000,000 OTHER: $ B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea acadentl $ ANY AUTO 15909629 7/8/2021 7/8/2022 BODILY INJURY(Per person) $_ __ SCHEDULEDO AUTOS ONLY X �RE� �N yy�Ep � BODILY INJURY(Per accident) $ X AUTOS ONLY j X i AUTO ONLY (Per accident) DAMAGE $ $ C X_ UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 1,000,000 EXCESS LIAB CLAIMS-MADE 7/8/2021 7/8/2022 AGGREGATE S 1,000,000 • DED X I RETENTION$ 10,000 S D WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABIUTY X STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE YIN WC201900019843 7/8/2021 7/8/2022 E.LEACHACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N N/A E.L DISEASE-EA EMPLOYEE $ 1'000'OOO If yes.describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Property PK201900018166 7/8/2021 7/8/2022 BPP 225,000 A Property 'PK201900018166 7/8/2021 7/8/2022 BI 350,000 1 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Issued as evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Cityof Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. 210 Main Street Northampton,MA 01060 AUTHORIZED REPRESENTATIVE Z '� 1k fikt. --, ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Conskroa l i164 prvisor CS-t0 ?� 113 I ,M f�pires:06/07J2023 COLRAiii • j O� • Commissioner dada J. , HOME IMPROVEMENT C:ONTRAC:TOR Registration valid for individual use only TYPE.LI_C, before expiration• If found return to: Registration n Office• Onsurna '• rs and Business Regulation 169tirl: ;l't 312023 1000 i ••>•S 1. -Suite 710 NL;P.'MEAST SOLAR DESIGN ASSOC 02118 / h. w Gk6i;CJkY GARRISON ie._n am, 13E.F.:.W$T (iow,d/::L i' >w.>!c _ ali/tttl valid tJi A1'FIE NIA 0:03:, Undersecretary valid �� nature U ifi‘ , L 1 A ....0. r lADA4) 4 ( W ail- ,t.)oti NeO poNt /71--I• 11 gig-3 • let '� `" , i t 4 P 4 '' ,s �, " lig 4 '''' ' . ' ' • 4: ' , Ostr, 4 4, '' 4 •‘`,,' s, ..".• .. „k .,"..% - . -. . . -, i 4.- , v-, - ,t. . . ,, , , . . , . . . . ,, .4,,, . . ,_ , .... ., . i , _ „ ,,. . Y ., , .., P' bbb s s kror lit .....lot <. .� .rt- 1} �i ., � S.•. � k� r a s '�.. HIL FL Pr) p 4 i fI ti fin iv i \ Y ,� 1. f S Roof mounted solar array with 5`PAi<� ; I , 41% 28x LG modules and II 28x Enphase IQ7PIus-72-2-US ;., 6 _ _ . .,t''� r iI. . 1 microinverters ty rtX V' 4 , 6 10' . It. , : ,,,,... --1-111—„, 4.,,, P"C.1:144.411v:;,",..,41.1c11:,rP :„... .. , , 46 i At Alkt -401 :,. ... ,4 ,k'I, \1 4 'yam r,� y�J 'x� ; P r4 ya 41 \ w y 1- "k -40 niiillitt ' ,'1 .''" Main electric R. t `j �� . V , A - - panel in ' ' •,, • - 1,,,.. ''1'_ r' Ai „ 40... N basement A; � v. _ 4 , •• •4 , ., . r- . ii ,,,,„, t...4fi Thomas Sylvan 63 Park Hill Rd '4, Florence, Ma 01062 ..1‘ Northeast Solar Vreeland Design Associates An integrative approach to design engineering and site planning Date: August 11, 2021 To: Justin Annis Northeast Solar 136 Elm Street Hatfield, MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: Tom Sylvan, 63 Park Hill Rd, Florence, MA: Structural assessment of existing house roof to support proposed solar array. I have investigated the existing roof framing of the 28'x 48', 1-1/2-story split-level ranch style house with a walkout basement garage. Based on the Assessor's records the house was constructed in 1983. 28 PV solar panels are to be installed on the front south facing roof. The rafters are 2x8 installed at 16"on-center, spanning 13'-6"over a 24' long section and spanning 11'-6"over the remaining 24' with the longer overhang sheltering the front entry. The roof pitch is 5.5/12. 2x6 ceiling joists are attached to the bottom of the rafters and prevent the roof from spreading. The roofing is composite asphalt shingles. I have reviewed the mounting details for the proposed solar arrays. Based on my calculations and on the specified PV solar panel unit weight of 45± Ibs, with the attachment points of the array placed at a maximum of 4' on center and staggered to minimize the load to any one rafter, the existing rafters are adequate to support the proposed PV solar array and the snow and wind load requirements of the current MA State Building Code for the City of Northampton. Please contact me if you have any questions or need additional information. Sincerely, ("C‘:\OF MgssgcDAVID A. y VREELAND P L 4:1-A fo CIVIL Y 3 =f *.cisitioy. 46 David Vreeland, PE Vreeland Design Associates /pNA 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 a • a CD LG355N1K-A6 I LG360N1 K-A6 I LG365N1K-A6 Preliminary1111 355W I 360W I 365W The LG NeON®2 is LG's best selling solar module and one of the most powerful and versatile modules on the market today.The cells are designed to appear all-black at a distance,and the performance warranty guarantees 90.6%of labeled power output at 25 years. WPM°PRODUCT C 42) US E cc. 25' YEAR PRODUCT•PERFORMANCE•LABOR WARRANTY Features Enhanced Performance Warranty 25-Year Limited Product Warranty ® ' LG NeON®2 Black has an enhanced The NeON®2 Black is covered by a 25-year , performance warranty.After 25 years, J limited product warranty.In addition,up to$450 LG NeON®2 Black is guaranteed at least of labor costs will be covered in the rare case 90.6%of initial performance. that a module needs to be repaired or replaced. Solid Performance on Hot Days � Roof Aesthetics '7/ LG NeON®2 Black performs well on hot LG NeON®2 Black has been designed with days due to its low temperature coefficient. aesthetics in mind using thinner wires that appear all black at a distance. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA,Inc. LG LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar energy source research program in 1985,supported by LG Group's vast expenence in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoX0 series to the market,which is now available in 32 countries The NeONS(previous MonaXS NeON),NeONe2,NeONe2 8iFacial won the"Intersalar Llfe'S Good AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. LG NeON'2 Black Preliminary LG355N1K-A6 1 LG360N1K-A6 1 LG365N1K-A6 General Data Electrical Properties(STC*) Cell Properties(Matena&Type) Monocrystalline/N-type Model '+. 46 LG365N116A6 Cell Maker LG Max m .... 355 360 -.. 365 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) - [V] 343 34.7 35.1 Number of Busbars 12EA _ MPP Current(Impp) , [A] 1037 10.39 10.41 Module Dimensions(I x W x hi) 1,740mm x 1,042mm x 40 mm _ Open Circuit Voltage(Vac(Vac!'5% ,;) . . [V] 4 41.6 41.7 41.8 Weight _ 18.6kg Short Circuit Current(Isct5%) [A] 5 10.84 10.88 10.92 Glass(Material) Tempered Glass with AR coating Module Efficiency [%] 19.6 19.9 20.1 Badrsheet(Color) Black Power Tolerance [%] 0-.3 Frame(Material Anodized Aluminium `STC(Standard Test Condition).Irradiance 1000 W/m',cell temperature 25 C,AM 1.5 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes Measurement Tolerence of Pmax.t 3% Cables(Length) 1,100mm x 2EA Connector(Type/Maker) MC 4/MC Operating Conditions Operating Temperature -40-+85 Certifications and Warranty Maximum System Voltage 1,000(UL/IEC) :1' IEC 61 21 5-1/-1-1/2:2016,IEC61730-1/2:2016, Maximum Series Fuse Rating 20 UL 61730-1:2017,UL 61730-2:2017 Certifications- ISO 9001,150 14001,150 50001 -Mechanical Test Load`(Front) 5,400 OHSAS 18001 Mechanical Test Load.(Rear) INR41, 4,000 - -- - -- `Based on IEC 61215-2 2016(Test Load-Design Load a Safety Factor(1.5)) Salt Mist Corrosion Test'- 61701:2012 Severity 6 - Mechanical Test Loads fi 000Pa/5 400Pa based on IEC 61215:2005 Ammonia Corrosion Test _ EC IEC62716:2013 Module Fire Performance,._'. Type2(UL61730) Packaging Configuration Fire Rating Class C(UL 790,ULC/ORD C 1703) Number of Modules per Pallet [EAl I 25 Solar Module Product Wn aattgr 25 Year Limited -- Solar Module Output Warranty .';..z Linear Warranty' _-- Number of Modules per 40'Container [EA] 650 'Improved 1"year 985%,from 2-24th year-0.33%Jyear down,90.6%at year 25 Number of Modules per 53'Container [EA] 850 "In progress Packaging Box Dimensions(Ix W x H) [rem] 1,790 x 1,120 x 1,213 Paclmging Box Dimensions(L x W x H) [in] I 70.5 x 44.1 x 47.8 Temperature Characteristics Packaging Box Gross Weight [kg] 500 NWT* ['C] 42 t 3 - - - --- - -- _- Packaging Box Gross VVeight Db] 1,102 Pmax [%/'C] -0.35 Voc [ ] -- -- -0.26 ----- Isc [96PC] 0.03 Dimensions(mm/inch) `NMOT(Nominal Module Operating Temperature)Irradiance 800 W/m',Ambient temperature 20'C, Wind speed 1 m/s,Spectrum AM 1 5 1042.0/41.0(See of Seer Side) a. Electrical Properties(N M OT) 10020/39.4(Distant between Grounding 6 Mounting Noes) Min Model LG3 rt.... '.' too/i s/ 175.0/69 Mardmurn Power(Pmax) [W].>' 266 270 274 16-8.0.30/03s0.1 ' A EEEvoc) 02 39.2 393 39A , 8.8.5s12.0/0.3s0.5 �-I 8.72 875 8.78 M0areeg Holes I-V Curves 1150.0/453 i r I Cable Length 8 3 t 20- 1000W f Z 10.0- e00w j jSy I d S -A ... 6.0- QQ 400W g M ...., ::: 200W • 0.0 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 Q vduye M ` ni 2 _ 1 ® LG Electronics USA,Inc Product specifications are subject to change without notice. LG Solar Business Division LG355-365N 1 K-A6.pdf 2000 Millbrook Drive 121520 Lincolnshire,IL 60069 Life's Good www.lg-solarcom 0 2020 LG Electronics USA,Inc.All rights reserved. Tech Brief //r IRONRIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless - Y extreme weather events. Not just the worst storms in years, r � -<. but the worst storms in 40 years. High winds capable of 2 ripping panels from a roof, and snowfalls weighing �} ; enough to buckle a panel frame. ,,, _i 4- ` t XR Rails are the structural backbone preventing r '- these results. They resist uplift, protecti in. : -1 against buckling and safely and efficiently :- transfer loads into the building structure. - Their superior spanning capability 1 Y y requires fewer roof attachments, ,, 4. reducing the number of roof , - rt penetrations and the amount of installation time. "a/,,, 6 _, *4%14104'-.0// •••, , , i 1 ;3 Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails -, , . is specially designed to increase strength in both " z'(10 directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000-series ; ^� compatible with a range of tilt leg aluminum alloy,then protected with an 11 Flash Foot and options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing attachments. applications. s a more attractive appearance. IN Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF) Wind (MPH) 4' 5'4" 6' 8' 10' 12' 90 120 None 140 XR10 XR1000 160 • 90 120 20 140 160 90 30 160 90 40 160 80 160 ( 120 160 ( `Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. ©2020 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.20 ,��_ ', :"' ' '' - - . .77: --; , '7.-- 4,..:r- :- . - ..,.. SUN ....„ ;, , ,.. a,„ _,,,,,,,,, ....,-, ,,,..,,= eY „_, ., _ ` s re ,-• ' .,. INSTALLATIONMADE EZ & EZR! 1 E Z a ‘Iiiik -. EZR r ti • 4 S U r1 IVI O C� O'S best-selling i EZ Roof Mount is the industry standard for PV system The EZ & EZR Advantage mounting on any composite ✓ Leak-proof design protects shingle roof. sealing points from elements. ✓ ICC Certified for both rafter and Now, SunModo introduces a decking solution. smaller footprint, EZR Roof ✓ Exceptional resistance to corrosion Mount flashing, where truss and wear. anchoring can be assured, embossed design minimizes ✓ A wide variety of L-feet and standoffs available. bending, and only one tool is needed. ✓ Surprisingly easy to install! Key Features of EZ and EZR viwor.0 . o .4411110, MODEL EZ Mount EZR Mount Raked teardrop design diverts water from the roof penetration. ✓ f I 1 360-degree L foot positioning, serrated L foot on both sides for rail mounting. ✓ 1 J 1 1 A wide variety of L-feet and standoffs available. 1 1 1 Versatile mounting option includes direct-to- decking for easy installation. r 1 1 Stamped emboss features stiffen the flashing to minimize bending. Only one tool is needed. '41( Technical Data Application Composite shingle Material High grade aluminum, 304 stainless steel hardware Finish Clear anodized, silver or black powder coated Flashing Size EZ Roof Mount: 10.00 x 12.48 x 0.04 inches EZR Roof Mount: 8.00 x 1 1 .38 x 0.03 inches Roof Attachment EZ Roof Mount: Rafter and decking EZR Roof Mount: Rafter only Structural Integrity IBC and IRC compliant Warranty 20 years SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com