20025 mineral hills winery 3 DEC 2020 (1)This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPlan North
Drawn by:
Checked by:
Scale:
Date:
20-025
JPB
JPB
AS NOTED
12/3/2017
Project No.:
Rev Date Description
1 12/3/2020 PERMIT SETProposed Renovations to MINERAL HILLS WINERYat GODARD'S RED HEN FARM592 Sylvester RoadFlorence, MassachusettsPLANS
A-1exist h.w.h.PROPOSED FLOOR PLAN AT NEW RESTROOMS
Scale: 1/4" = 1'-0"2
±6'-0"
existing covered walkway
Existing hot water heater.
Connect water supply to
new restrooms.existing conc. walknew sidewalkNew sidewalk to
covered, exterior
shed & tasting
room. Slope walk
to align level with
existing covered
walkway.
16'-5"7'-6 3/4"8 1/2"3 1/2"6'-1 1/4"6'-0" clear, finished5 1/2"5 1/2"7'-7 1/4"
7'-6" clear, finished
3 1/2"7'-7 1/4"
7'-6" clear, finished
5 1/2"
1'-6 5/8"
typ.
1'-6 5/8"
typ.
2'-0"2'-0"
EXTERIOR WALL
5/8" GWB at interior
Vapor barrier
2x6 @ 16" OC
Min. R-21 insulation per Code1/2" ZIP sheathing
Metal wall panel to match existing
building
3'0"x7'0" insulated metal door w/
ADA compliant lever hardware.
Provide ADA compliant door
closer. Provide ADA compliant
door threshold.
6"3'-6"1'-0"3'-6"42" long x 1-1/2" OD grab
bar
alignalign w/ existing posts at porch13'-8 3/4"22'-1"6'-0"EQ.EQ.NEW WALK TO EXIST. COVERED TERRACEexist h.w.h.PROPOSED FLOOR PLAN
Scale: 1/8" = 1'-0"1EXISTINGRESTROOM ADDITIONRESTROOM ADDITION
EXISTING
TASTING ROOM
AND STORE
FERMENTATION
ROOM
WAREHOUSE,
STORAGE &
SHIPPING
EXISTING WALKNEW WALKAPPROXIMATE PATH OF
SANITARY LINE TO
HOLDING TANK - TO BE
DETERMINED IN FIELD
BY PLUMBING
APPROXIMATE LINE OF
EXISTING FENCING. MODIFY AS
REQUIRED BY WORK AT NEW
RESTROOM ADDTION
APPROXIMATE LOCATION OF
NEW HOLDING SANITARY
HOLDING TANK. LOCATION
TO BE VERIFIED IN FIELD BY
PLUMBING AND TANK
INSTALLER.
NEW COVERED WALKWAY AT
RESTROOM ADDITION. SLOPE
CONCRETE OR PAVER WALK TO
MATCH LEVEL AT EXISTING FRONT
PORCH. WALKWAY TO BE LEVEL AT
ENTRY TO RESTROOMS. EXTEND
PORCH ROOF ALONG SIDE AND
NORTH ELEVATION OF RESTROOM
ADDITION.
NEW RESTROOM ADDITION
This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPlan North
Drawn by:
Checked by:
Scale:
Date:
20-025
JPB
JPB
AS NOTED
12/3/2017
Project No.:
Rev Date Description
1 12/3/2020 PERMIT SETProposed Renovations to MINERAL HILLS WINERYat GODARD'S RED HEN FARM592 Sylvester RoadFlorence, MassachusettsEXTERIOR
ELEVATIONS
A-2
Top of wall, existing
Fin. floor, existing
Fin. floor, new
Bot. footing
4
12
Extend existing porch roof at
new restroom addition. Tie new
roof into existing roof.
Metal siding to match existing
at new addition.
Top of wall, existing
Fin. floor, existing
Fin. floor, new
Bot. footing
New wood post at new
addition covered walk /
porch. Match style of posts at
existing.
4
12
±312
Continue fascia & overhang
at new addition porch. Match
profile.
ADDITIONEXISTING
Top of wall, existing
Fin. floor, existing
Fin. floor, new
Bot. footing
Top of wall, existing
Fin. floor, existing
Fin. floor, new
Bot. footing
Existing roof at covered
walk / porch
Existing post at covered
walk / porch
New roof at addition. Match
existing. Flash into existing.
Flashing at
bot. of siding.
New insulated fiberglass door & metal
frame at restroom entry. 3'0"x7'0" w/ ADA
compliant privacy hardware. Provide ADA
compliant door closer, ea. door. Provide
ADA compliant metal threshold, ea. door
Metal siding to match existing
at new addition.
New wood post at new
addition covered walk /
porch. Match style of posts at
existing.
Infill wall as required at
junction of new addition
and exisitng building. New
or re-used siding to match
existing.
Tie overhang at new roof
into existing roof
overhang. Match profile.
New roof at addition. Match
existing. Flash into existing.
EAST (STREET) ELEVATION
Scale: 1/4" = 1'-0"1
NORTH ELEVATION
Scale: 1/4" = 1'-0"2 WEST ELEVATION
Scale: 1/4" = 1'-0"3
This drawing is not intended nor shall it be used for construction purposes unless the Signed professional seal of a registered architect employed by Jody Barker, Architecture & Design, LLC is affixed. The Architect shall be deemed the author of these documents and shall retain all common law, statutory and other reserved rights, including the copyright.JODY BARKER, A.I.A. | Architecture + Design, LLC32 Willow StreetFlorence, Massachusetts 01062cell: 617.216.5988e: jodybarker.aia@gmail.comPlan North
Drawn by:
Checked by:
Scale:
Date:
20-025
JPB
JPB
AS NOTED
12/3/2017
Project No.:
Rev Date Description
1 12/3/2020 PERMIT SETProposed Renovations to MINERAL HILLS WINERYat GODARD'S RED HEN FARM592 Sylvester RoadFlorence, MassachusettsBUILDING
SECTION AT
ADDITION
A-3
MATERIALPRODUCTTRADENAMEMODELNUMBER
BUILDING SECTION AT NEW RESTROOMS
Scale: 3/4" = 1'-0"1
Top of wall, existing
Fin. floor, existing
Fin. floor, new
Bot. footing2'-0"4"±10'-8"Existing pre-cast pier foundation
Existing slab
Existing exterior wall
Existing truss framed roof
1'-5"3'-0"3'-6"1'-0"7'-6" ceiling ht.±3
12
New 2x12 @ 16" OC wood framed roof at new addition. Overframe new roof onto existing roof. Demo existing metal
roofing as required to reach existing roof sheathing. 5/8" sheating
at new roof. Install new metal roofing to match existing. Flash
roofs as required.
R-49 insulation, per Code at attic space
1-1/2" O.D. grab bar as indicated on plans.
5/8" GWB at ceiling & walls
Tile wall base, TBD
Tile floor, TBD
1'-0"6'-8 1/4"
New reinforced conc., slab-on-grade & foundation at restroom addition.
6-mil. vapor barrier below slab
2" rigid insul., continuous below slab, R-10
8-10" gravel
Match fascia type & profile of
existing porch.
Cont. flashing
8"x5.5" conc. curb
Ice & water shield at base of wall to bot. of ftg.
Flashing to protect insulation at foundation
New side walk
±2'-2"
Rigid insulation installed
horizontally, min. 2'0"
EXTERIOR WALL
5/8" GWB at interior
Vapor barrier
2x6 @ 16" OC
Min. R-21 insulation per Code
1/2" ZIP sheathing
Metal wall panel to match existing building