Loading...
05-058 (4) ill 371 AUDUBON RD BP-2022-0022 GIS#: COMMONWEALTH OF MASSACHUSETTS • Map:Block: 05 -058 CITY OF NORTI�I', AMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM B V ILDING1 PERMIT Permit# BP-2022-0022 - Project# JS-2022-000027 Est. Cost: $63624.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: NORTHEAST SOLAR DESIGN ASSOCIATES LLC 106113 Lot Size(sq ft.): 203860.80 Owner: HELFAND IRA&DEBORAH E SMITHII Zoning:RR(102)/ Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC AT: 371 AUDUBON RD Applicant Address: Phone: Insurance: 136 ELM ST (413) 247-6045 0 Liability HATFIELDMA01038 ISSUED ON:7/19/20210:00:00 TO PERFORM THE FOLLOWING WORK:•INSTALL 31 PANELi11.32 KW SOLAR SYSTEM ON ROOF WITH 20 KW BATTERY SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter:, Footings: Rough: Rough: House# Fouindation: Driveway Final: Final: Final: Rough Frame: 7 Gas: Fire Department ! Fireplace/Chimney: Rough: ( Oil: Insu lation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. 1` • Certificate of Occupancy signature./ i • FeeType: Date Paid: Amount: Building 7/19/2021 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner Ner-0 I-102c: I o.Jl-p f Dui 20 I4W 4 v ate. , Fi go. , i of , ` , C.) Oeparbrientlule Oak ' City of No m pt�ri c� ,,_i+ `ci Per m 1 y Building 9Q ppa tint c, .' Penrtlt 212 Main S . , i -Avai'attllit Room" oo 6' ell '' atalli&y Northampton, MA o (?1 T of tru a Plans .. phone 413-5137.1240 Fax 41 € , 2 It. APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOV° '°OR DE LISH'A ONE OR TWO FAMILY DWELLING SECTION 1-SITE INFORMATION 1.f Ebesant+t Addr _ - This section to be completed by office 371 Audubon Rd Map Lot Unit Northampton MA 01060 tome Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2,1 Owner of Record: PO Box 324 Ira Helfand and Deborah Smith Northampton MA 01060 . U ��-.r"' � ��"' Jw,fi ,` Y�A$h4�e urt,Address: swell� � A 413-320-7829 Sklr aly►ra, ! L LI I 22 Authorized Agent orth-,- , o : — 136 Elrn St,Hatfield, MA 01038 `4 rre(Print: Curren:Malin,Address: ; %�� 413-247-6045 Sigr 1ure lit ! Teti:wh ortl SECTION3.-E_ 'II T;�- II CT'ION C'v STS Item • Estimated Coat(Dollars)to be Official Use Only I convicted by permit applicant 1. Building /a'l Building Permit Fee 2. Electrical al)Estimated Total Cost of Construction from f61 3. Plumbing Building Permit Fee A. Mechanical 0-(V, C} 44176- 5.Fire Protection S. Total=(1 +2+3+4 +5) $63.624 Check Number i ,2 ///6 This Seat GO Far Official Use Only Building Permit Number60- ' ' a'a Date Issued_. Signature: 7- i q-zozf fits+'+tin,:D.rris.4onen'trsper,Wr.x.Hutdings L}nte Section 4. ZONING AU information must i Completed, Permit Can ig prAed Om`re incomplete inte rrnatien Existing Proposad Rixuircd by Zoning Titii Mi mn 10 bc IIkd in by flubding Deparaner. Lot Sisk ' 1 , ._— -—I Fronkas ,_._ .�,_�_... . - _ _. .. . .-. Setbacks Front E L:_._ sidc i;I.. R: L:J l R_:..— .._I I:._ H l.___.. .; Rear Ea] E Building Height = _-1 1---_- 1 Bldg. Square Footage 771 L , �-- n Space Footage 1 narkinzl #_of EWPZ SilliaCP I--+ Fell: Natal=&L.acniFcr- A. Has a Special Permit/Variance/Finding ever been issued forlon the site? {O0 DONT KNOW 0 YES IF YES, date issued: 1F YES: Was the permit recorded at the Registry of Deeds? NO OONT KNOW 0 YES IF YES: enter nook 1 Page ® and/or Document ft li. Does the site contain a brook, body of water or wetlands? NO 0 Dom.IQ{OW ��4 YES IF YES,has a permit been or need to be obtained from the Consehratiori Commission? Needs to be obtained ed Obtained l , Date Issued: C. Do any signs exist on the property? YES 0NO to IF YES, describe size, type and location: O. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO ►:�. IF YES, describe size, type and location: E. '6Mill the construction activity d irb(et ng,grading, aaxatian,ar filling}over 1,scre or is it part of a ocinrr plan that will disturb agar 1 acre? YES NO IF YES,then a Northampton Storn,Weber Management Pam it from the DPW is required. • CTIDN S-DESCRIPTION OP PROPOSE W�RK'f h It _ � o �eok� a t I New House ® Addition ❑ Replacement Windows Alterations} ❑ Roofing Q Or Doors 0 Accessory Bldg. ® Demolition ❑ . New Signs (0] Decks jil Siding ID) Other(NI Brief Description of Proposed Warts: Install 31 solar panels on Roof andk f vtol tylk e'. 5 $it1M Alteration of existing bedroom Yes No Adding new bedroom Yes No 6 I20tWk Attached Narrative Renovating unfinished basement Yes __No 0( Plana Attached Roll -Sheet lbs..WNeyf.hctutstyalnjt r: 6'1 bre&**Sting lion stnai-ciiminiti .1 ci1C iiisi •a. Use of building:One Family Two Family Other b. Number of roams in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction_ Dimensions e. Number of stories' f. Method of heating? Fireplaces or Woodetomes Nu mbar of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes N o j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building end Zoning regulations? Yes No. I. Septic Tank City Sewer Pnwate well City water Supply SECTION Js-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I Ira Helfand and Deborah Smith ,as owner of the subiect property hereby authorize Northeast Solar to ad on. y beh- .in all ;;=•fore relative to wort authorized b this building permit applicationi.. 11.0 ,,,,i,:-4-,_...-c----.1::••-•,,,. ,,'._,' -'), 1 F Si,. artredrOA Ief Dale I, Gregory Garrison/Northeast Solar ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application ire true and accurate,to the best of my knowledge end belief. Signed under the pains and penalties of perjury. .. • Gregory Garrison priid nstree cji2 ( sadurtt 4r aArterfAgjwil. • SECTION S-CONSTRUCTION SERVICES SA Licpppgl Construct'orkStlpepvlpor: Not Applicable 0 Phillip Baunsgard Hanna of License Header: CS 10 6113 Lir er ae Number 41 Heath Rd Colrain, M 01340 6/7/25 ALtir-•_ J/� Expiration Date V. . 0 �//, // 413-247-6045 -11, na elaphone 4.Reglstenid Hoene I over ent.Cantrsctorr . ; ' n,_,_ ,. ,� ., . . ,�J Not Applicable ❑ Northeast Solar 169641 Compaoli Name Registration Number 136 Elm S47,.. Hatfield, Ma 01038 7/13/2021 Address - Expiration Data Telephone 413-247-6045 SECTIION 1S-WO '' «Ill'I PENSAT ON INSURANCE AFFIDAVIT'("M.G.L,c 1S , 25C(6))d Workers Compensation Insurance affidavit must be completed and submitted with this application:.Failure to provide this affidavit will result in the denial of the issuance of the building permit Signed Affidavit Attached Yes )Sl Na 0 iI L -Home Owner Exemption The current exemption for 4'homcowners'was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not posses a license,provided that the owner acts as_sneer-lsar.CAR 7410,_SSixtb_Etildon Section tO&.3.5.1g RefinItIonof Homeowner:Person(a)who own a parcel of land on which bei she resides or intends to reside,on which there is,or Es intended to be,a one or two family dwelling,attached or detached structures accessory to such use and.'or farm structures.A person who constructs more than one home In a Iwo-Year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building OibciaL that hefshe shall be responsible.fora]l_suclr_wwark¢rerformed_onder_tile bnildinlr permit, As acting gontriaction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued_ Also be advised that with reference to Chapter 152(Workers'Compenmtion) and Chapter 353(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for p€rsan(s) you hire to perform work for you under this permit. The undersigned{'homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of • Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated_ Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: 5-1 I /LA u4OVI The debris will be transported by: A10(11ALA,64- (af- (..noto The debris will be received by: ft's'f'rV0-4-aLiLi Building permit number: Name of Permit Applicant : Na(kVIAifr S 'Ltr 0e,-) stit W V 2 I • Date ature of Per pplicant The Commonwealth of Massachusetts Department of Industrial Accidents Office of f Investigations _= ;!, 1 Congress Street, Suite 100 H��I Baston,MA0211�2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print L egibly Business/Organization Name: Northeast Solar Address:136 Elm St. City/State/Zip:Hatfield,Ma 01038 Phone#:413-247-6045 Are you an employer?Check the app rep riate box: Business Type(required): 1. 0 I am a employer with 17 employees(full and/ 5• ❑Retail or part-time).* 6. ❑Restaurant/Bar/EatingEstablishment 2.El I am a sole proprietor or partnership and have no 7. ❑Office and/or Sales(incl.real estate, auto, etc.) employees working for me in any capacity. [N o workers' comp.insurance required] 8. ❑Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑Entertainment , their right of exemption per c. 152,§1(4), and we have 10.0 Manufacturing no employees.[No workers'comp.insurance required]** 4.0 We are anon-profit organization, staffed by volunteers, 11.❑Healthcare with no employees.[No workers' comp.insurance req.] 12.13 Other *Any applicant that checks box#1 mist also fill cut the sectionbelow slowing theirwoikers'compensation policyinfon ation "If the cooporate officer lave exempted themselves,but the corporation has other employees,awoskers'compensation policy is sequined and suck an osganiationskasld cleckba c#1. I am an employer that is providing workers'compensation insar mce for my employees. Slow is the policy information. Insurance CompanyName:Gotham Insurance Company Insurer's Address: 371 Audubon Rd City/State/zip: Northampton MA 01060 P olicy#or S elf-ins.Lic.K #WC201900019843 Expiration Date: 7/8/2021 Attach a copy of the workers'comp ensationp olicy declaration page(showing the p olicy number and exp iration date). Failure to secure coverage as required under Section25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of aISTOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for ance coverage v;rification. I do hereby certify,under 'rts r 1,perjury that the information provided above is trace and correct. V Signature: - D ate: 4/19/2021 11 �•Phone#:413 247-604 4 : - Official use only. Do not write ' this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.nm s gov1dia �...4) NORTSOL-01 MMONSINI ACORO® DATE(MM/DD/YYYY) 4.---- CERTIFICATE OF LIABILITY INSURANCE 7/10/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Roblin Insurance Agency PHONE FAX 144 Gould Street Suite 100 (NC,No,Est):(781)455-0700 (NC,No):(781)449-8976 Needham,MA 02494 att DRESS:certificates@roblininsurance.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Gotham Insurance Company INSURED INSURER B:Safety Insurance'Company 39454 Northeast Solar Design Associates,LLC INSURER C:New York Marine and General Insurance Company 16608 136 Elm Street INSURER D: Hatfield,MA 01038 INSURER E: I INSURER F: COVERAGES CERTIFICATE NUMBER: 1 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP'1 LIMITS LTR INSD MDIMM/DD/YYYY) IMMIDDIYYYYI A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR PK201900018166 7/8/2020 7/8/2021 DAMAGE TO RENTED 000,300 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: i GENERAL AGGREGATE $ 2,000,000 POLICY X JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ ANY AUTO 5909629 7/8/2020 7/8/2021 BODILY INJURY(Per person) $ OWNED SCHEDULED AUT�O�S ONLY X AUTOSyy�E BODILY INJURY(Per accident) $ X AUTOS ONLY X AUTO ONLY (Per acEcidentDAMAGE $ $ A X UMBRELLA UAB X OCCUR EACH OCCURRENCE $ 1,000,000 EXCESS LIAB CLAIMS-MADE UM201900008269 7/8/2020 7/8/2021 AGGREGATE $ 1,000,000 DED X RETENTION$ 10,000 C WORKERS COMPENSATION •AND EMPLOYERS'LIABILITY Y/N WC201900019843 •� 7/8/2020 7/8/2021 X STATUTE ERH 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) 1 E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Property PK201900018166 7/8/2020 7/8/2021 BPP 225,000 A Property PK201900018166 7/8/2020 7/8/2021 BI 350,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Issued as evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Cityof Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN p ACCORDANCE WITH THE POLICY PROVISIONS. 210 Main Street 1 Northampton,MA 01060 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION.,All rights reserved. The ACORD name and logo are registered marks of ACORD Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Cc nst,11416WZIAiipprvisor 01, CS-106113 5' -- .� Etat�pires 06107/2023 PHILLIP BAl1, SGARDl 41 HEATH ROAD �, j -- COLRAIN MAQ130° �, f' ,,=1• dV0 • lSti;l;t' •. Commissioner (Iva ' HOME IMPROVEMENT CONTRACTOR Registration valid for Individual use only TYPE:_l_C before th expiration il aie, If found return to: PCegistrat: 0/113/ 021 Office 0 onsumar Affairs and Business Regulation 169fi4: „ll3i2021 1000,N ington Sir et -Suite 710 NORTHEAST SOLAR DESl5N ASSOC Bosto ,fy A 02118 GREGORY GARRISON 1� Ise rl_,v sT � t valid tv thou signature aTFIc'i.D MA 0`03.; Undersecretary tea# r. Main. electric !*. • • P. base,rne;nt Orr _—_ _ .,.. 2x Encharge10 f ' A battery modules. • , ; �t' I i. g in basement , a 14*.lt.;;T'2... • • - • •-"'"i'-- l''""...r ••:„, ,,,,, •_ ... „.:,,,. ..„..4..1p.:,,:• ...• .:,,....1‘. . ,. ...,...:„.„1:,c. :,?,....,1„.,,,, ..„,„,•••„,,, •••• • .. ki. �� t .. 7,,rn©© ��"`�' s °� 5'i" .err- gyp•, t'.,� •. . . ¢ g 11 . _ 3 a. s .tea . -10 -V-::---* t .,:-7=1 ---:": '‘-t--,••::-.. . -.' .1-..:::.-• . ,r R 1 # v a r t ti '' � s,.1 .' .Z }:,1 '_'� i;; • Y 1. a t i F�- - .. iE. • 4' . »1 "' "t:e .:. _ y pf M � 8 4 Ira Helfand 371 Audubon Rd . Northampton, Ma 01060 Northeast Sol Vreeland Design Associates An integrative approach to design engineering and site planning Date: April 26, 2021 To: Justin Annis NorthEast Solar 136 Elm Street Hatfield,MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: Ira Helfand, 371 Audubon Rd,Northampton, MA: Structural assessment of existing house roof to support proposed solar array. I have investigated the existing roof framing for the proposed PV solar panel installation. The 2- story, 28'x 40' colonial style house was constructed in 1986. 31 PV solar panels are to be installed on the back south facing roof. The house roof is framed with 2x8 rafters installed 16"on-center, spanning 13'-6"with a roof slope of 7.5/12. The 2x8 attic joists are secured to the bottom of the rafters and prevents the roof from spreading. The roofing is composite asphalt shingles. I have reviewed the mounting details for the proposed solar array. Based on my calculations and a PV solar panel unit weight of 45±lbs,with the attachment points of the array placed at a maximum of 4' on-center and staggered to minimize the load to any one rafter,the existing house roof framing is adequate to support the proposed PV solar array and the snow and wind load requirements of the current MA State Building Code for the City of Northampton. Please contact me if you have any questions or need additional information. Sincerely, (c.0:0 OF MAssq * DAVID VREELAND vs VA-4A_AdJ o CIVIL rn -4 " No. 4631�`' David Vreeland, PE ,, Vreeland Design Associates ��"SS/ONA ekG\ 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 sz 'sue. . LG N ON®2 Black I , - * ., , , . _,AD , , : ' LG355N1K-A6 I - LG360N1 k-A6 ` I . .LG365N1 K-A6 .Preliminary ' , .1,. - ________:,_ 355W I 360W I 365W The LG NeON®2 is LG's best selling solar module and one of the most powerful and versatile modules on the market,today.The cells are designed to appear all-black at a distance,and the performance warranty guarantees 90.6%of labeled power output at 25 years. � � us CE $E! f .,,, * : YEAR ,, )PRODUCT•PERFORMANCE•LABOR - WARRANTY "" '' • Features Enhanced Performance Warranty i 25 Year Limited Product Warranty zs;`' LG NeON®2 Black has an enhanced ® The NeON®2 Black is covered by a 25-year performance warranty.After 25 years, limited product warranty.In addition,up to$450 LG NeON®2 Black is guaranteed at least of labor costs will be covered in the rare case 90.6%of initial performance. that a module needs to be repaired or replaced. Solid Performance on Hot Days + Roof Aesthetics •ket • _- LG NeON®2 Black performs well on hot LG NeON®2 Black has been designed with , days due to its low temperature coefficient. aesthetic in mind using thinner wires that appear all black at a distance. When you go solar, ask for the brand you can trust: LG Solar About LG a in Electronics USA,Inc. 7. LG f LG Electronics is a global leader in eelectronicp ronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked or a solar L energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoX®series to the market,which is now available in 32 countries.The NeONe(previous MonoX®NeON),NeONe2,NeONa2 BiFacial won the"Intersolar AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. Life S Good LG NeON®2 Black Preliminary LG355N1K-A6 I LG360N1K-A6 I LG365N1K-A6 General Data Electrical Properties(STC*) (,Cell'Properdes(MaterialType) Monocrystalline/N-type Model LG355N1KA6 'LG360N1KA6 LG365N1K-A6't I Cell Maker LG fMaximumPower(Pmax).: [W]: 355 360 365 !Cell Configuration. - 60 Cells(6 x 10) '.MPP Voltage(Vmpp) - . [V] 343 34.7 35.1 ;(Number of Busbars ' 12EA !:MPP'Cunent(Impp) [A], 10.37 10.39 10.41 !Module Dimensions(LxW x:H) 1,740mm x 1,042mm x 40 mm Open C'vcuit voltage(Voc_+ 5%), °M ! 41.6 41.7 41.8 1Neight 18.6 kg 'Short Circuit Current( ) [A] 10.84 10.88 10.92 - Isct5%'� Glass(Material). Tempered Glass with AR coating ''Module Efficiency ., i.Badaheet(Color) ` _ [%] 19.6 19.9 20.1 Black i Power Tolerance i Frame(Material) _ Anodized Aluminium *STC(Standard Test Condition):Irradiance 1000 W/m',cell temperature 25'C,AM 1.5 Junction'Box(Protection Degree)', IP 68 with 3 Bypass Diodes Measurement Tolerence of Pmax:t3% Cables(Length) - 1,loommxSEA Connector.(Type/Maker)- MC4/MC Operating Conditions OperatingTemperature. (*C]- -40-+85 Certifications and Warranty I Maidmum SystemVoltage . ' [V] 1,000(UL/IEC) AC 61 21 5-1/-1-1/2:2016,IEC 61730-1/2:2016, '}M - • Maximum5eries Fuse Rating [A] 20 UL 61730-1:2017,UL 61730-2:2017 - - 'Certifications";, ISO9001,ISO 14001,ISO 50001 MechanicalTest Load"(Front) [Pa/Psf]., 5,400 , • OHSAS 18001 1MechanialTest Load*,(Rear)' . [Pa/psf] 4,000 *Based on IEC 61215-2:2016(Test Load-Design Load x Safety Factor(1.5)) 'Salt Mist Corrosion Test IEC 61701:2012 Seventy 6 Mechanical Test Loads 6,000Pa/5,400Pa based on IEC 61215:2005 ';AmmoniaCorrosionTest IEC 62716:2013 ]Module Fire Performance - Type 2(UL 61730) 1 Fire Rating. Class C(UL790,ULC/ORD C 1703) Packaging Configuration _ j:NumberofModules.per Pallet, [CAI, 25 S Solar Module Product Warranty ' 25 Year Limited Solar Module Output Warranty Linear Warranty" j:NumberofModules per 4,0'Container [EA] 650 . ''Improved:1'year 98.5%,from2-24th year:-0.33%/year down,90.6%at year 25 lNumberof Modules per 53'Container = [EA]. 850 *In progress !'Packaging Box Dimensions(Lx Wx H)'. [mm] 1,790 x 1,120 x 1,213 [,Packaging.Box Dimensions(Lx.WxH) [in]' 70.5x44.1 x47.8 Temperature Characteristics • j,Paclaging Box Gross Weight [kg] 500 ?NMOT; [°C]` 42±3 ' . PackagingBoxGrossWeight • [lb] 1,102 %.Pmax .[55/°G]�. -0.35 '',Voc [%/°C]: -0.26 ''Isc, [%rC]- 0.03 Dimensions(mm/inch) *NMOT(Nominal Module Operating Temperature):Irradiance 800 W/m',Ambient temperature 20°C, Wind speed 1 m/s,Spectrum AM 1.5 1042.0/41.0(Sze of Short Side) Electrical Properties(NMOT) 10020/39.4(oistance between Grounding&Mounting Holes) Model LG355N1K-A6 LG360N1K-A6„LG365N1KA61 40.0/1.57 Maximunr Pmax(Power ) ' [W]; 266 270 274 -• �/ 16-80 x3.0/03 a 0.1 �MPP Voltage(Vm _pp) 'M . 322 32.6 33.0 Drain Holes MPP Current Onion) [A], 8.27 8.28 8.30 Junction Box Grounding Holes � Open Circuit Voltage(Voc)- " " [V],' 39.2 393 39.4 , ns.o/6s• e-8.5z 12.0/03x0.5 ' }Short Circuit Current(Isc) '[A]'., 8.72 8.75 8.78 Mounting Holes I-V Curves 1150.0/45.3 f ,§ Cable Length q rn 12.0- 1000W E 5 5 10.0- BOOW . H 600W n 1--)\ r.,' 1 1 l'''' 6.0- - 1 400W 4.0- 200W z.o- 0.0 m 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 ry o c Voltage(V] ✓ -. -. \ , .•--- LG Electronics USA,Inc. Product specifications are subject to change without notice. • LG Solar Business Division LG355-365N1 K-A6.pdf 2000 MillbrookOrive 121520 Lincolnshire,IL 60069 Life's Good www.lg-solar.com ©2020 LG Electronics USA,Inc All rights reserved. Tecl .Brief:: /k IRONRIDGE XR Rail Family Solar as Not Always Sunny Over their lifetime, solar panels experience countless ; --,,\ extreme weather events. Not just the worst storms in years, _ but the worst storms in 40 years. High winds capable of �,L� ,` �; �. ripping panels from a roof, and snowfalls weighing '� �� enough to buckle a panel frame. +.� S� , ,-. �=y i XR Rails are the structural backbone preventing ,;(' � these results. They resist uplift, protect � � ® `-. against buckling and safely and efficiently - ® `- " ` �\ ®� .1%1 transfer loads into the building structure. ,F �� pop . .�,,� � �,,,�-,.,. Their superior spanning capability . " ® �` ' N- .„--..,, --.„S �. ®® requires fewer roof attachments, . yam`/ 4 ` ®��� reducing the number of roof � �� ��� t� � v,.. penetrations and the amount `,, ;., '-, ¢ d;n '= ��� �`' of installation time. .` t �.." , 0` ¢.. %1' :' " ram fo,., .,."'„,, ''''' ''.:i t jf a•f • r: ,1 a J�h.. o .I ,J Force-Stabilizing Curve • I. • b : Sloped roofs generate both vertical and lateral -' forces on mounting rails which can cause then °•W..••' ' '`; to bend and twist.The curved shape of XR Rails �° • .r d� k;" •is •specially designed to increase strength in both �' • 4 directions while resisting the twisting.This unique ° , feature ensures greater security during extreme ',.. ° ° y °° 1 weather and a longer system lifetime. Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials ,` S ,' , XR Rails are -. IronRidge offers All XR Rails are made of 6000-series riAlv,i , compatible with �8m�►71►`r a range`of tilt leg aluminum alloy,then protected with an t r ' ® FlashFoot and fd°, rrn options for flat anodized finish.Anodizing prevents surface a¢ ( ; other pitched roof r..1. 1' C.r` roof mounting and structural corrosion,while also providing . : attachments. � , ' applicati 4� ons. a more attractive appearance. °ft. "rr w!`e • ' . " 5 r, s .: Y m ' ti.„4:B4e', *e5 $. ° * pP ": 4 . Lro. s " a a: ^$.Y.. , ., " 4 `re � "1 .'11- ,, ... . "A`"`�'i%,I6 5 * ,.;r:,s e',' `st �C` ' aL" w "' r� s gyp,.. s t`,;A "`' t �,v`.5max'��.,g.;.,a:�... .. ,. .� ..w �`�_��4>,i-.w.,�,�.nt:.a,.'�* .,,.��:r .:roY:� ,+ .+w°s.,�.,s;�" i.: , x„ •:r�vt...a>....,,.x&gsw .. « -;^.g$ r�,,°F,U.,;'�s���. J���..�s,."�.a�s�,..r�x ,� .,.. ..,� Tech:Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.*Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load . - Rail'Span, Snow.(PSF) , Wind.(MPH} : 4' - ' 5'4" 6' 8' 10' 1`2'' 90 - .; 120 5- None ' 140 XR10, ' - XR 100 = "i XR1000.: s" { 160 ,4$ ,.4 .„'J •• e ,,.4 MM-,,,,-. 90 I f^ �W A'.� � •f yt 120 :l ,�� 20 160 6 rt''' ,, -- 90 .I30 , , 160 • 1' - ': 4 �V 90 1 40 . 160 it n 17 120 160 :._ �� ' `Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. • 0.2020 lronR dge.Inc.All rights reserved.Visit www5ronridge:com or call 1-8OO-227 9523,for more information.Version 1 20' `` ��® SUNMOD�. I N STAL LAT I O N MAD E EVEZR! EZ EZR r SunModo's best-selling. fx , EZ Roof Mount is, the industry. The EZ & EZR Advantage standard for PV system mounting, on any composite . ✓ Leak-prol'of design protects shingle, roof.. sealing points from elements. ./ ICC Certified for both rafter and Now, SunModo introduces a , ° decking (solution. • smaller footpri,nt,, EZR Roof . ./ Exceptional resistance to corrosion Mount flashing, where truss and wear. affchoring can be assured, , e b ./ A wide variety of L-feet and embossed design: moinimti3zes. . standoff available. • bending, and only one tool: , . . •is4 needed. . , ' . . ✓ Surprisingly easy to install? Key Features of EZ and EZR SvNM A • • 1 I O 1 MODEL EZ Mount ; EZR Mount 0 I 1 1 I Raised teardrop design diverts water from the I I , roof penetration,. 360-degree L foot positioning, serrated L foot on.• both sides for rail mounting. 1 , , A wide variety°ofL-feet and standoffs.available. . Versatile mounting,option.includes direct-to- decking for easy instalIation. 1 1 , Stamped emboss features stiffen'the flashing;to. 1 1 minimize bending. 1 , , Only one tool is needed '14(' I I I 1 1 , , Technical Data Application Composite shingle Material High grade aluminum, 304 stainless steel hardware Finish Clear anodized, silver or black powder coated' Flashing Size EZ Roof Mount: 10.00 x 12.48 x 0.04 inches EZR Roof Mount: 8.00 x 11 .38 x 0.03 inches Roof Attachment EZ Roof Mount: Rafter and decking EZR Roof Mount: Rafter only Structural. Integrity IBC and IRC compliant Warranty 20 years SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com 5/8" Type X gypsum mounted to floor joist extending 24" past perimeter of battery footprint. Qty. 2 @ Enphase Encharge 10 Batteries mounted on wall Concrete Basement Wall Note, house has hardwired smoke detectors