Loading...
31B-253 (24) 33 ELM ST-ALUMNAE HOUSE BP-2021-1363 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 31B-253 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:renovation BUILDING PERMIT Permit# BP-2021-1363 Project# JS-2021-002246 Est.Cost: $17588108.00 Fee: $123117.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SHAWMUT DESIGN & CONSTRUCTION 048817 Lot Size(sq.ft.): 77101.20 Owner: SMITH COLLEGE OFFICE OF THE TREASURER Zoning: EU(100)/URC(100)/ Applicant: SHAWMUT DESIGN & CONSTRUCTION AT: 33 ELM ST - ALUMNAE HOUSE Applicant Address: Phone: Insurance: 560 HARRISON AVE (617) 622-7000 WC BOSTONMA02118 ISSUED ON:6/17/20210:00:00 TO PERFORM THE FOLLOWING WORK:INTERIOR & EXTERIOR RENOVATIONS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. ( � , • SQO I Certificate of Occupancy Signatu . • ,' 157 FeeType: Date Paid: Amount: Building 6/17/2021 0:00:00 $123117.90 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner • The Commonwealth of Massachusetts14Y /8 Office of Public Safety and Inspections,, 449/ Massachusetts State Building Code(780 CMR) Building Permit Application for any Building other than a One-orIN4Tamily Dwelling •(This Section For Official Use Only) ".'' c_,,31-1=�ri 70 Building Permit Number:$p ea (3 U3 Date Applied: Building Official: SECTION 1:LOCATION 33 Elm Street Northampton 01060 Smith College Alumnae House No.and Street City/Tow Zip Code Name of Building(if applicable) 31 B / 31 D 31B-253 1D-102 Assessors Map# and/or Lot # SECTION 2:PROPOSED WORK Edition of MA State Code used If New Construction check here 0 or check all that apply in the two rows below Existing Building El Repair® Alteration ® Addition 0 Demolition 0 (Please fill out and submit Appendix 2) Change of Use 0 Change of Occupancy 0 Other 0 Specify: Are building plans and/or construction documents being supplied as part of this permit application? Yes El No 0 Is an Independent Structural Engineering Peer Review required? Yes 0 No 011 Brief Description of Proposed Work: Full interior renovation and exterior restoration of historic components. Interior work includes all new mechanical,electrical, plumbing and life safety systems and interior fit-up. Means of Egress will be upgraded to be compliant. The existing fire escape will be demolished and replaced.Accessibility will be upgraded.A new elevator will be installed serving all floor levels. SECTION 3:COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATION,ADDITION,OR CHANGE IN USE OR OCCUPANCY Check here if an Existing Building Investigation and Evaluation is enclosed(See 780 CMR 34) ❑ Existing Use Group(s): A-2, A-3, B Proposed Use Group(s): A-2, A-3, B SECTION 4:BUILDING HEIGHT AND AREA Existing Proposed No.of Floors/Stories(include basement levels)&Area Per Floor(sq.ft.) 5 9,000 5 9,000 Total Area(sq.ft.)and Total Height(ft.) 29,000 64 29,000 64 SECTION 5:USE GROUP(Check as applicable) A: Assembly A-1 0 A-2 El Nightclub 0 A-3 ® A-4 0 A-5 0 B: Business III E: Educational 0 F: Factory F-1 0 F2 0 H: High Hazard H-1 0 H-2 0 H-3 0 H-4 0 H-5 0 I: Institutional I-1 0 I-2 0 I-3 0 I-4 0 M: Mercantile 0 R: Residential R-10 R-2 0 R-3 0 R-4 0 S: Storage S-1 0 S-2 0 U: Utility 0 Special Use 0 and please describe below: Special Use Description: SECTION 6:CONSTRUCTION TYPE(Check as applicable) IA 0 IB 0 IIA 0 IIB 0 IIIA 0 IIIB ® IV 0 VA 0 VB 0 SECTION 7:SITE INFORMATION(refer to 780 CMR 105.3 for details on each item) Water Supply: Flood Zone Information: Sewage Disposal: Trench Permit: Debris Removal: El Public El Check if outside Flood Zone 0 Indicate municipal A trench will not be Licensed Disposal Site Private 0 or indentify Zone: or on site system 0 required 0 or trench or specify: permit is enclosed El Railroad right-of-way: Hazards to Air Navigation: MA Historic Commission Review Process: Not Applicable XI Is Structure within airport approach area? Is their review completed? or Consent to Build enclosed 0 Yes 0 or No® Yes 0 No SECTION 8:CONTENT OF CERTIFICATE OF OCCUPANCY Edition of Code: Ninth(780 CMR)Use Group(s): A-2.A-3,B Type of Construction: IIIB See drawing A1.07 Does the building contain an Sprinkler System?: Yes Special Stipulations: None Ground Floor=115 Design Occupant Load per Floor and Assembly space: F�Conference Hall=297 -Media Center/Lounge=52 -Living Room/Lounge=80 Second Floor=72 Third Floor=33 SECTION 9: PROPERTY OWNER AUTHORIZATION Name and Address of Property Owner The Trustees of Smith College 10 Elm Street Northampton MA 01063 Name(Print) No.and Street City/Town Zip Property Owner Contact Information: Capital Construction Director 413-585-2406 - - pgagnon@smith.edu Title Telephone No. (business) Telephone No. (cell) e-mail address If applicable,the property owner hereby authorizes: Peter Gagnon 126 West Street Northampton MA 01063 Name Street Address City/Town State Zip to apply for and act on the property owner's behalf,in all matters relative to work authorized by this building permit application. SECTION 10:CONSTRUCTION CONTROL(Please fill out Appendix 1) If a building is less than 35,000 cu.ft.of enclosed space and/or not under Construction Control then check here❑. Otherwise provide construction control forms(see section 107 in the code)as required. 10.1 Registered Professional Responsible for Construction Control (the professional coordinating document submittals) Marianne McKenna 416-977- 5104 31529 Name(Registrant) Telephone No. e-mail address Registration Number 8/31/2021 351 King Street Ease.Ste 1200 Toronto.ON Canada M5A 0L6 Architect Street Address City/Town State Zip Discipline Expiration Date 10.2 General Contractor Shawmut Design and Construction Company Name Steven DeLisi CS-048817 Name of Person Responsible for Construction License No. and Type if Applicable 560 Harrison Ave Boston MA 02118 Street Address City/Town State Zip 617-.622-7000 617-352- 5897 SDeLisi@shawmut.com Telephone No.(business) Telephone No. (cell) e-mail address SECTION 11:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§25C(6)) A Workers'Compensation Insurance Affidavit from the MA Department of Industrial Accidents must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Is a signed Affidavit submitted with this application? Yes MI No 0 SECTION 12:CONSTRUCTION COSTS AND PERMIT FEE Item Estimated Costs: (Labor 17 588108 and Materials) Total Construction Cost(from Item 6)=$ 1.Building $10,812,350 Building Permit Fee= $7.00 per$1000 pn Coct x (Inert here 2.Electrical $ 2,263,271 =$123,117. 3.Plumbing $ 506,589 4.Mechanical (HVAC) $ 3,793,331 Note:Minimum fee=$ 100 (contact municipality) 5.Mechanical (Other) $ 212,267 (Sprinkler) Enclose check payable to City of Northampton 6.Total Cost $17,588,108 (contact municipality)and write check number here # si g416G SECTION 13:SIGNATURE OF BUILDING PERMIT APPLICANT By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the be of my knowledge and understanding. Douglas Lake Project Manager 857-337-8138 05/12/21 Please print and sign name Title Telephone No. Date 650 Harrison Ave Boston iStlk 02118 _QLake@shawmut.com Street Address City/Town State Zip Email Address I 2 P , - Go '1 Municipal Inspector to fill out this section upon application approval: g � 0A Name ' I Dae CITY OF NORTHAMPTON SETBACK PLAN MAP: LOT: LOT SIZE: REAR LOT DIMENSION: REAR YARD RENOVATION PROJECT REFER TO PROJECT DRAWING SHEETS A1.00 AND C-200 SIDE YARD SIDE YARD FRONT SETBACK FRONTAGE nor City of Northampton s —. si '' Massachusetts <t L '�".< ( : 1 R DEPARTMENT OF BUILDING INSPECTIONS g r I! 212 Main Street • Municipal Building yJ �f "- lir Northampton, MA 01060 'r�y`'4««»4 WO110 CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number [by official] is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: HOLYOKE TRANSFER STATION, 686 Main Street, Holyoke, MA 01040 The debris will be transported by: Name of Hauler: WASTE MANAGEMENT, INC. Signature of Applicant: Date: 05/12/21 1 ne uommonweaun of lvlassacnusetts ►�; Department of Industrial Accidents Office of Investigations WINO t�t,.P 600 Washington Street Boston, MA 02111 • www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Shawmut Woodworking & Supply, Inc. dba Shawmut Design and Construction Address: 560 Harrison Avenue City/State/Zip: Boston, MA 02118 Phone #: 617-622-7000 Are you an employer? Check the appropriate box: Type of project(required): 1.❑ I am a employer with 4. ❑X I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑ New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. X❑ Remodeling ship and have no employees These sub contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.t required.] 5. ❑ We are a corporation and its 10.111 Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.111 Roof repairs insurance required.] t c. 152, §1(4), and we have no 13.❑ Other employees. [No workers' comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. The Charter Oak Fire Insurance Co. Insurance Company Name: Policy#or Self-ins. Lic. #: U BO R4283962025 H Expiration Date: 1 1/01/2021 Job Site Address: 33 Elm Street City/State/Zip: Northampton, MA 01160 Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature: Date: Phone#: 61 622- 114 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3. City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: TRAVELERS J WORKERS COMPENSATION ONE TOWER SQUARE AND HARTFORD CT 06183 EMPLOYERS LIABILITY POLICY TYPE v INFORMATION PAGE WC 00 00 01 ( A) POLICY NUMBER: UB-0R428396-20-25-H NJ TAX IDENTIFICATION NO. : 042759985000 RENEWAL OF (VTROUB-1C79107-2-19) INSURER: THE CHARTER OAK FIRE INSURANCE COMPANY A Stock Company 1 NCCI CO CODE: 15318 INSURED: PRODUCER: SHAWMUT WOODWORKING & SUPPLY, AON RISK SERVICES NE INC INC. 53 STATE ST FL 22 560 HARRISON AVE BOSTON, MA 02109 BOSTON, MA 02118 Insured is A CORPORATION Other work places and identification numbers are shown in the schedule(s) attached. 2. The policy period is from 11-01-20 to 11-01-21 12:01 A.M. at the insured's mailing address. 3. A. WORKERS COMPENSATION INSURANCE: Part One of the policy applies to the Workers Compensation Law of the state(s) listed here: AL AZ CA CO CT DC DE FL GA HI ID IL IN KS KY LA MA MD ME MI MN MO NC NE NH NJ NM NV NY OK OR PA RI SC SD TN TX UT VA VT WI B. EMPLOYERS LIABILITY INSURANCE: Part Two of the policy applies to work in each state listed in item 3.A. The limits of our liability under Part Two are: Bodily Injury by Accident: $ 1,000,000 Each Accident Bodily Injury by Disease: $ 1,000,000 Policy Limit Bodily Injury by Disease: $ 1,000,000 Each Employee C. OTHER STATES INSURANCE: Part Three of the policy applies to the states, if any, listed here: AR IA MS MT WV D. This policy includes these endorsements and schedules: SEE LISTING OF ENDORSEMENTS - EXTENSION OF INFO PAGE 4. The premium for this policy will be determined by our Manuals of Rules, Classifications, Rates and Rating Plans. All required information is subject to verification and change by audit to be made ANNUALLY DATE OF ISSUE: 09-22-20 AJ OFFICE: HARTFORD CT 084 PRODUCER: AON RISK SERVICES NE INC G9651 Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute, an employee is defined as "...every person in the service of another under any contract of hire, express or implied, oral or written." An employer is defined as"an individual,partnership, association, corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the receiver or trustee of an individual, partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally, MGL chapter 152, §25C(7) states "Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub-contractor(s) name(s), address(es) and phone number(s)along with their certificate(s) of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships (LLP)with no employees other than the members or partners, are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition, an applicant that must submit multiple permit/license applications in any given year, need only submit one affidavit indicating current policy information(if necessary) and under"Job Site Address"the applicant should write"all locations in (city or town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e. a dog license or permit to burn leaves etc.) said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address, telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 Tel. # 617-727-4900 ext 406 or 1-877-MASSAFE Fax # 617-727-7749 Revised 4-24-07 www.mace unv/di a 1 Initial Construction Control Document \ ti ! To be submitted v�Tith the bui:ding permit application by a r' Registered Design Professional \N„,..„ ;, t for work per the ninth edition of the •_��'` Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Date: May 12, 2021 Smith College Alumnae House Renovation Property Address: Project: Check(x)one or both as applicable: New construction Existing ConstructionX Project description: Marianne McKenna I MA Registration Number:31529 Expiration date:8/31/21,am a registered design professional,and I have prepared or directly supervised the preparation of all design plans,computations and specifications concerningl: ArchitecturalX Structural X Mechanical X Fire Protection X Electrical X Other: for the above named project and that to the best of my knowledge, information, and belief such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I (or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1_ Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable_ 3_ Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 1I7_ When required by the building official,I shall submit field/progress reports(see item 3.)together with pertinent comments,in a form acceptable to the building official. Upon completion of the work,I shall submit to the building official a'Final Construction Control Document'. "wet" �I� v �\\E�d; Enter in the space to the right a or c electronic signature and seal: ' ^'Q roHUNiO ,y , Phone number: 416-977-5104 Email:kpmb@kpmbarchitects.com Building Official Use Only Building Official Name: Permit No.: Date: Note 1.Indicate with an'x`project design plans,computations and specifications that:you prepared or directly supervised If'other'is chosen,provide a description. Version 01 01 201g Appendix 1 Construction Documents are required for structures that must comply with 780 CMR 107. The checklist below is a compilation of the documents that may be required. The applicant shall fill out the checklist and provide the contact information of the registered professionals responsible for the documents. This appendix is to be submitted with the building permit application. Checklist for Construction Documents* Mark"x"where applicable No. Item Submitted Incomplete Not Required 1 Architectural X 2 Foundation X 3 Structural X 4 Fire Suppression X 5 Fire Alarm(may require repeaters) X 6 HVAC X 7 Electrical X 8 Plumbing(include local connections) X 9 Gas(Natural,Propane,Medical or other) X 10 Surveyed Site Plan(Utilities,Wetland,etc.) X 11 Specifications X 12 Structural Peer Review X 13 Structural Tests&Inspections Program X 14 Fire Protection Narrative Report X 15 Existing Building Survey/Investigation X 16 Energy Conservation Report X 17 Architectural Access Review(521 CMR) X 18 Workers Compensation Insurance X 19 Hazardous Material Mitigation Documentation X 20 Other(Specify) 21 Other(Specify) 22 Other(Specify) *Areas of Design or Construction for which plans are not complete at the time of application submittal must be identified herein.Work so identified must not be commenced until this application has been amended and the proposed construction document amendment has been approved by the authority having jurisdiction. Registered Professional Contact Information 49538 Gregory D Shreve 6178h8-1200 nontact@)lemessitrier corn Registration Number Name(Registrant) Telephone No. e-mail address 1380 Soldiers Field Road Boston MA 02135 Structural 6/30/22 Street Address City/Town State Zip Discipline Expiration Date 50643 John K Wieber 203-866-5538 sfplotner@altierisw.com Registration Number Name(Registrant) Telephone No. e-mail address 31 Knight St Norwalk CT 06851 MEP 6/30/22 Street Address City/Town State Zip Discipline Expiration Date 40075 John T Difini _617--338--0063 info@nitscheng.com Registration Number Name(Registrant) Telephone No. e-mail address 2 Center Plaza,Suite 430 Boston MA 02108 Civil 6/30/22 Street Address City/Town State Zip Discipline Expiration Date Please follow this link for construction control forms to be used by Registered Design Professionals. DATE(MM/DD/YYYY) "A ORO CERTIFICATE OF LIABILITY INSURANCE 05/13/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If • SUBROGATION IS WAIVED, subject to the terms and conditions of the .=policy, certain policies may require an endorsement. A statement on this t certificate does not confer rights to the certificate holder In lieu of such endorsement(s). N, PRODUCER CONTACT Aon Risk Services Northeast, Inc. NAME: Boston MA Office (A/CNNo.Eat): (866) 283-7122 FAX No) (800) 363-0105 53 State Street E-MAIL = Suite 2201 ADDRESS: Boston MA 02109 USA INSURER(S)AFFORDING COVERAGE NAIC# INSURED INSURER A: The Travelers indemnity Co. 25658 Shawmut woodworking & Supply Inc INSURERS: The Charter Oak Fire Insurance Company 25615 dba Shawmut Design and Construction 560 Harrison Ave INSURER C: Travelers Property Cas Co of America 25674 Boston MA 02118 USA INSURERD: Starr Indemnity & Liability Company 38318 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 570087312337 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES,LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. Limits shown are as requested INSR ADDL SUER POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER IMM/Ormyyr I IMbI/DD(CYYYI LIMITS A X COMMERCIAL GENERAL LIABILITY VTRKCo8206A920IND20 11/01/2020 11/01/2021 EACH OCCURRENCE S3,000,000 DAMAGE TO RENTED $3OO,OOO CLAIMS-MADE X OCCUR PREMISES(Ea occurrence) MED EXP(Any one person) $10,000 PERSONAL S ADV INJURY $2,000,000 r` GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE S6,000,000 m POLICY X PRO- X co JECT I LOC PRODUCTS-COMP/OPAGG S6,000,000 0o OTHER: O O t\ C AUTOMOBILELIABILRY VTJ-CAP-8206A932-TIL-20 11/01/2020 11/01/2021 COMBINEDSINGLELIMIT $1,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) •• 0 OWNED SCHEDULED BODILY INJURY(Per accident) Z AUTOS ONLY _ PROPERTY DAMAGE AUTOS HIRED AUTOS NON-OWNED t~i —ONLY —AUTOS ONLY (Per accident) D UMBRELLA LIAB X OCCUR 1000584632201 11/01/2020 11/01/2021 EACH OCCURRENCE $5,000,000 X EXCESS LIAB CLAIMS-MADE AGGREGATE $5,000,000 DED RETENTION B WORKERS COMPENSATION AND UB0R4283962025H 11/01/2020 11/01/2021 X I PER STATUTE IOTH EMPLOYERS'LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT S1,000,000 OFFICER/MEMBER EXCLUDED? N N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 101 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) RE: Project No. 171336, Project Name: Smith College Alumnae House Renovation, Location: 33 Elm Street, Northampton, MA try 01063. The Trustees of the Smith College, its agents, its employees and its assigns are included as Additional Insured with '?sc respect to General Liability where required by written contract. 06.2 54 CERTIFICATE HOLDER CANCELLATION 1■ SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Smith College AUTHORIZED REPRESENTATIVE ¢� 126 west Street Northampton MA 01063 USA ele � _ c(Xon c�% Cp�sGLveed ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD AGENCY CUSTOMER ID: 570000037534 • LOC#: �--� ADDITIONAL REMARKS SCHEDULE Page _ of _ AGENCY NAMED INSURED Aon Risk Services Northeast, Inc. . Shawmut woodworking & Supply Inc POLICY NUMBER See Certificate Number: 570087312337 CARRIER NAIC CODE See Certificate Number: 570087312337 EFFECTIVE DATE: ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: ACORD 25 FORM TITLE: Certificate of Liability Insurance Excess Liability up to $25M 2nd Excess Layer: Policy No#US00064417L120A Insurer: XL Insurance America, Inc. Policy Term: 11/1/20-11/1/21 Layer Limit: $10M xs $5M Each Occurrence: $10M Aggregate: $10M 3rd Excess Layer Policy No. : XCQG46820277004 U/W Co.: ACE Property & Casualty Insurance Co. Policy Term: 11/1/20 - 11/1/21 Limit: $10M excess of $15M Each occurrence: $10,000,000 Aggregate: $10,000,000 ACORD 101(2008/01) ®2008 ACORD CORPORATION.All rights reserved. The ACORD name and logo are registered marks of ACORD Commonwealth alt of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Constr4Jctiort Supervtsor CS -048817 Expires : y y, .�. STEVEN L DELISI 8 MORGAN ST 6173525897 HOLYOKE MA 01040 r Commissioner /t-il-4t'444-- , w......,.. .i. _...„......„, ..y ?o`.1HAMpro CITY OF NORTHAMPTON, MASSACHUSETTS .liti , -. DEPARTMENT OF PUBLIC WORKS p 7,)',I` - -, 125 Locust Street Trench Permit Number: la '' Northampton,MA 01060 Date Approved: <:a 413-587-1570 Fax 413-587-1576 Expiration Date: (for City Use Only) EXCAVATION/TRENCH PERMIT Pursuant to G.L. c. 82A and 520 CMR 14.00 et seq. (as amended) This permit must be fully completed prior to consideration. Submit completed form with permit fee to Northampton Department of Public Works, 125 Locust Street,Northampton, MA 01060. This permit is issued under the provisions of M.G.L. c. 82A, 520 CMR 14.00 and applicable sections of the Revised Ordinances of the City of Northampton, including, but not limited to, Section 285-21. Fee: $250 Check#: Date Issued: Name of Applicant Primary Phone# Douglas Lake,Project Manager Shawmut Design and Construction 857-337-8138 Street Address Emergency Phone# 560 Harrison Ave 617-352-5897[Steve DeLisi, Project Super] City/Town State Zip Email Boston MA 02109 dlake@shawmut.com Name of Excavator Primary Phone# T&M Equipment 413-785-1941 Street Address Emergency Phone# 177 Rocus Street 413-374-9951 City/Town State Zip Email Springfield MA 01104 j.champigny@tandmequipcorp.com Name of Property Owner(s) Primary Phone# The Trustees of Smith College 413-585-2406 Street Address Emergency Phone# 10 Elm Street 413-585-2490 City/Town State Zip Email Northampton MA 01063 pgagnon@smith.edu Insurance Certificate# Policy Expiration Date 570084388433 Name&Contact Information of Insurer Aon Risk Services Northeast,Inc. 53 State Street,Suite 2201,Boston MA 02109 USA Dig Safe#& Start Date from Dig Safe Ticket: TBD-Dig Safe to be on site approximately 5/18/21 Project Description/Location of Work. Provide the following: ❑Description of purpose and exact location of proposed work including description of what is to be laid or repaired in the proposed trench (e.g. water pipe, sewer pipe, drain pipe, gas line, power line, communication lines, etc.) ❑Sketch or drawing showing all proposed work. ❑Anticipated Start of Work Date. Description: Reference project drawing sheets C-200,C-500. Project is replacing the water main that services the building from Elm street,about 75'east of Bedford Terrace. Start date is approx.September 1,2021. Check if applicable: ❑ Emergency ® Work on Private Property ® Work in Public Right of Way O Work within State Layout(attach State Permit) O Work within 50' of a Public Shade Tree(see attached Public Shade Tree Regulations) 0 Tree removal required(see attached Public Shade Tree Regulations) 0 Tree protection,trimming, or root pruning required(see attached Public Shade Tree Regulations) 0 Work within 100' of a wetland or 200 Ft. of a stream or river (attach Permit) 0 Work within floodplain (attach permit) O Public Water/Sewer/Drain Entry Permit (attach permit, if available) ❑ Driveway Permit(attach permit, if available) O Pole and Wire Petition (attach approval) Pg.2/4 By signing this form, the applicant, owner and excavator all acknowledge and certify that they are familiar with, or, before commencement of the work, will become familiar with, all laws and regulations applicable to work proposed, including OSHA regulations, M.G.L. c. 82a, 520 CMR 14.00 et seq., and any applicable municipal ordinances, by-laws and regulations, and they covenant and agree that all work done under the permit issued for such work will comply therewith in all respects and with the conditions set forth below. The undersigned owner authorizes the applicant to apply for the permit and authorizes persons duly appointed by the municipality to enter upon the property to monitor and inspect the work for conformity with the conditions attached hereto and the laws and regulations governing such work for the duration of the construction. The undersigned applicant, owner and excavator agree jointly and severally to reimburse the municipality for any costs and expenses incurred by the municipality in connection with this permit and the work conducted thereunder, including but not limited to enforcing the requirements of state law and conditions of this permit, inspections made to assure compliance therewith, and measures taken by the municipality to protect the public where the applicant, owner or excavator has failed to comply therewith, including police details and other remedial measures deemed necessary by the municipality. The undersigned applicant, owner and excavator agree jointly and severally to defend, indemnify, and hold harmless the municipality and all of its agents and employees from any and all liability, causes or action, costs and expenses resulting from or arising out of any injury, death, loss or damage to any person or property during the work conducted under this permit. By signing this form, the applicant, owner and excavator acknowledge that they have read and understand all the information set forth in and referenced within this application package and that they agree to comply in all respects with the requirements therein. Douglas Lake, Project Manager,Shawmut Design and Construction. 05/12/21 Applicant Date Excavator Signature(if different) Date Owner Signature(if different) Date To be completed when approved permit is picked up. Pg.3/4 By signing below, the applicant acknowledges and agrees to all the conditions of approval stated below and validates this permit. 05/12/21 Apfi t Date For City Use-- Do not write in this section Department Approvals/Comment Water: Sewer/Storm Drain: FPC: Streets: Traffic Signals: ❑ Subject to 5-yr. pavement moratorium Road last paved: ❑ Special Conditions: Fee ❑ $250 Permit Application received(Check payable to the City of Northampton) ❑ Waived. Reason: ❑ Tree mitigation: Permit Approval Director of Public Works Date Pg.4/4 Excavation/Trench Permit Policy Permit Requirements In accordance with the Revised Ordinances of the City of Northampton, Section 285-21,an excavation/ trench permit,commonly referred to as a Trench Permit, is required for any excavation within the City of Northampton road layout or on property owned by the City of Northampton. Under M.G.L.c.82A and 520 CMR 14.00,trench permits may also be required for work on private property. Call the Department of Public Works(413-587-1570) for a determination. This work may include,but shall not be limited to,underground utility installation or repair,driveway or walkway construction,or installation of signs,trees or other features.Trench permits are issued by the Department of Public Works. The fee for a trench permit is$250. Trench Permits are valid for thirty calendar days from the date of approval. Applicants will be notified by phone that their permit has been approved and they will have ten(10)business days to pick up and sign their permit. Permits not picked up within ten(10)business days will require the applicant to file for a permit extension. If a permit is not picked up for a period of 30 days,a new permit will be required.Applicants whose application for trench permit has been disapproved will be notified in writing. Permits will generally be issued within 10 business days,but this may be extended during periods when high volumes of permit requests are received. Emergency requests will be handled on a case by case basis and expedited to the extent possible.Permits will not be valid until the applicant has picked up and signed the approved permit. If work is to be completed within 50'of a Public Shade Tree, see Public Shade Tree Regulations. The Department of Public Works recognizes an excavation moratorium for roadways that have been reconstructed or have had pavement overlay for a period of 5 years from the date of completion.Trench permits will not be issued for areas subject to this moratorium except in cases of emergency. No work shall be allowed in the public right-of-way between November 15th and March 15th or during winter conditions, as determined by the DPW Director. All work within the public right-of-way must be completed by November 15.No trench permit will be issued for work in the public right-of-way that cannot be completed by November 15. Permits for work in the public way do not remain valid through the winter and a new permit will be required for work in the spring Permits may be extended by up to 1 month or until November 15 unless interrupted by winter conditions,as determined by the DPW Director. To obtain a permit extension,the applicant must submit a completed Excavation/Trench Permit Extension Request to the Northampton Department of Public Works, 125 Locust Street,Northampton,MA 01060 for consideratiOn. Requests for extension should include a brief explanation of the reason for the request and a projected completion date.There is no fee for permit extensions. Applicants will be notified of the approval or disapproval of their request. Permit extensions are not valid until they have been approved in writing by the DPW Director. Applicants are advised to request an extension in advance of the termination date of the initial permit to allow sufficient time for processing of the extension request. Work may not proceed without a valid,fully signed Trench Permit or extension thereof which must be posted in plain view at the project location. If proposed work is located within the State layout,a copy of the State permit must be attached.The trench permit will not be approved without it. In accordance with Section 285-21 of the Revised Ordinances of the City of Northampton,the applicant shall agree to hold the City of Northampton harmless from all claims for damages whatsoever. A certificate of Liability Insurance listing the City of Northampton as an Additional Insured and indicating general liability coverage of $500,000 per person and$1,000,000 per claim or evidence of self-insurance in an equal amount is required under this permit. During construction,barriers, signage, lights and such other measures as may be necessary shall be erected and maintained for the protection of the public, in accordance with the Revised Ordinances of the City of Pg.5110 Northampton, Section 285-22. Traffic shall be maintained at all times during construction. If a police detail is required,it is the applicant's responsibility to schedule and pay for said detail. Contact the Northampton Police Department at 413-587-1105 to schedule a police detail. The Northampton Department of Public Works does not in any way warrant or guarantee accuracy of its utility markings. Said markings are provided from the best available information and should be considered to be approximate only. The applicant, in all operations,shall anticipate the existence of utilities that are consistent with local usage requirements. Construction Requirements Work shall conform with standards set forth in applicable sections of the Revised Ordinances of the City of Northampton, including but not limited to Section 290 Article VII,Design Standards,and the conditions set forth in the permit. The contractor shall notify the Department of Public Works when work has begun and upon completion. Work shall considered substantially complete after construction activities have been finished,temporary roadway pavement patch has been installed and all other surfaces and features have been appropriately restored. Prior to the start of excavation, bituminous concrete or concrete surfaces shall be cut vertically in a line parallel to the center line of construction,and slightly larger than the trench width,using an approved hand or power operated tool, so as to allow for trench excavation without further disturbance of the adjacent surfaces. Backfill will consist of the excavated material if it is declared suitable by the DPW Director or his/her assigns. If, in the opinion of the DPW Director, the excavated material is unsuitable, the entire material for filling shall consist of approved gravel or approved borrow as directed. Backfill will be placed in successive layers of not more than six inches in compacted depth. No frozen material shall be used as backfill. After thorough tamping around and beneath the utility, the six-inch layers of backfill will be thoroughly compacted by tamping with a mechanical rammer or by hand tampers having a tamping face not exceeding 25 square inches in area. If dry, the material shall be moistened and then compacted. All sub-base layers shall be compacted to not less than 95% of the maximum dry density of the material as determined by the ASTM D-1557 (Modified Proctor) compaction test at optimum moisture content. Controlled Density Fill (CDF) will be used in all cases, as the backfill material, when an emergency trench cut is required in a roadway which is subject to the five year moratorium,or as directed by the DPW Director due to the condition or intensity of use of the roa way. The method of installation and the specification for CDF shall be attached to this permit if required. Temporary trench patch is required at all disturbe paved roadway areas. A 3-inch temporary bituminous patch shall be installed within 24 hours f backfilling. After backfill has been in place for a period of at least 90 days, the temporary patch shall be removed. A cut shall be made at least 1'beyond each side of the trench. Where trench cuts or a series of trench cuts under the same permit or permitted by the same applicant are within 10' of one another, the pavement cut shall be enlarged to pave them with a single pavement patch. Permanent pavement patch shall be placed over 12" minimum depth of approved compacted gravel base. Permanent pavement patch shall consist of bituminous concrete Type I-1 (Hot Mix) laid in two 2-inch layers consisting of a base course, and a top course for a total finished pavement depth of 4-inches. The patch will be rolled with a 5-ton roller. The patch shall be neat, uniform and conform to the existing grade. Infra-red shall be required as determined by the DPW Director or his/her assigns. For 30-day permits, removal of the temporary patch and installation of the permanent patch will be considered as part of the initial permit and the applicant will be duly covered under said permit provided that the initial permit is posted on site and all other permit requirements have been met. Where Pg.6/10 permanent pavement patch cannot be installed prior to the onset of winter, it is expected that permanent pavement will be installed as soon as conditions become favorable in the spring. Full width overlay shall be required in pavement areas subject to a 5-year excavation moratorium. Existing pavement shall be milled to receive 1.5" minimum depth overlay of top course bituminous concrete pavement. The area subject to overlay shall extend at least 20 feet in all directions from the limits of excavation or as determined by the DPW Director. An asphalt emulsion tack coat shall be applied to the milled existing pavement prior to the placement of the overlay. Installed overlay shall be rolled to provide suitable compaction and to form a neat and uniform surface which conforms with existing grades. If, in the opinion of the DPW Director, a 6-inch cement concrete (Hi-Early Type) slab is necessary, it shall be laid over the backfilled trench extending 1-foot beyond each side of the trench and allowing for a 2- inch bituminous concrete surface. After a period of two days, a single layer of top course bituminous concrete Type I-1 (Hot Mix) shall be laid in a 2-inch in depth, and rolled with a 5-ton roller. Sidewalks and curbs shall be restored to match existing material, line and grade. Concrete sidewalks shall conform to the material and construction methods as specified in Section 701 of the Commonwealth of Massachusetts Department of Public Works Standard Specifications for Highways, Bridges and Waterways. In addition, all concrete sidewalks shall consist of 4,000 psi. concrete, reinforced with 10/10 six-by-six wire fabric and shall be placed to minimum depth of 4". A minimum depth of 6 inches of concrete is required at all driveway crossings. An 8" minimum depth base of approved, compacted gravel is required for all restored concrete sidewalks. Bituminous concrete sidewalks shall conform to the relevant provisions of Section 701 of the Commonwealth of Massachusetts Department ofPublic Works Standard Specifications for Highways, Bridges and Waterways. The bituminous concrete pavement shall be Type I-1 (Hot Mix) consisting of 1.5" layer of base course and 1.5" layer of top course. Afl 8" minimum depth base of approved, compacted gravel is required for all restored sidewalks. Lawn and grassed areas shall receive 6" minimum depth of good quality screened loam. Spreading of loam and seed shall be in accordance with Sections 751 acid 765 of Commonwealth of Massachusetts Department of Public Works Standard Specifications for Highways, Bridges and Waterways. Grass seed shall be in compliance with Materials Specifications Section M6.03.0 of the aforementioned document. Grass shall not be accepted until the DPW Director or his/her assigns has determined that it is well established and that good coverage and vigorous growth have been achieved. The applicant shall warranty installed grass for 1 year from the date of completion. The applicant shall warranty other aspects of the work, including but not limited to,settlement for a period of 5 years. Pavement markings, signs and all other features imp4cted by the work shall be restored in kind. Warranty The applicant shall warranty the trench cut for a 5-year period following approved installation of permanent roadway pavement patch or restoration of other surfaces and features. If repairs are required during the warranty period and the applicant is unwilling or unavailable,the Department of Public Works will contract for the necessary work and the applicant will be billed for all costs incurred. Violation Violation of this permit shall be assessed a fine of$50.00 per day for every day in non-compliance. Parties determined to be in non-compliance will be notified in writing. Parties in non-compliance will not be issued subsequent trench permits until the permit in violation is brought into full compliance. Pg 7/10 Conditions& Requirements Pursuant to M.G.L.c. 82A & 520 CMR 7.00 et seq. (as amended) By signing the application,the applicant understands& agrees to comply with the following: i. No trench may be excavated unless the requirements of sections 40 through 40D of chapter 82,and any accompanying regulations,have been met and this permit is invalid unless and until said requirements have been complied with by the excavator applying for the permit including,but not limited to,the establishment of a valid excavation number with the underground plant damage prevention system as said system is defined in section 76D of chapter 164(DIG SAFE); ii. Trenches may pose a significant health and safety hazard. Pursuant to Section 1 of Chapter 82 of the General Laws, an excavator shall not leave any open trench unattended without first making every reasonable effort to eliminate any recognized safety hazard that may exist as a result of leaving said open trench unattended. Excavators should consult regulations promulgated by the Department of Public Safety in order to familiarize themselves with the recognized safety hazards associated with excavations and open trenches and the procedures required or recommended by said department in order to make every reasonable effort to eliminate said safety hazards which may include covering, barricading or otherwise protecting open trenches from accidental entry. iii. Persons engaging in any trenching operation shall familiarize themselves with the federal safety standards promulgated by the Occupational Safety and Health Administration on excavations: 29 CFR 1926.650 et.seq., entitled Subpart P"Excavations". iv. Excavators engaging in any trenching operation who utilize hoisting or other mechanical equipment subject to chapter 146 shall only employ individuals licensed to operate said equipment by the Department of Public Safety pursuant to said chapter and this permit must be presented to said licensed operator before any excavation is commenced; v. By applying for, accepting and signing this permit,the applicant hereby attests to the following: (1) that they have read and understand the regulations promulgated by the Department of Public Safety with regard to construction related excavations and trench safety; (2)that he has read and understands the federal safety standards prorulgated by the Occupational Safety and Health Administration on excavations: 29 CMR 1926.650 et.seq.,entitled Subpart P,Excavations,as well as any other excavation requirements established by this municipality; and(3)that he is aware of and has,with regard to the proposed trench excavation on private property or proposed excavation of a city or town public way that forms the basis of the permit application, complied with the requirements of sections 40-40D of chapter$2A. vi. This permit shall be posted in plain view on the site of the trench. Summary of Excavation & Trench Safety Regulation (520 CMR 14.00 et seq.) This summary was prepared by the Massachusetts Department of Public Safety pursuant to M.G.L.c.82A and does not include all requirements of the 520 CMR 14.00. to view the full regulation and M.G.L.c.82A,go to www.mass.gov/dps. Pursuant to M.G.L. c.82, §1,the Department of Public Safety,jointly with the Division of Occupational Safety,drafted regulations relative to trench safety. The regulation is codified in section 14.00 of title 520 of the Code of Massachusetts Regulations(CMR). The regulation requires all excavators to obtain a permit prior to the excavation of a trench made for a construction-related purpose on public or private land or rights-of-way. All municipalities must establish a local permitting authority for the purpose of issuing permits for trenches within their municipality. Trenches on land owned or controlled by a public (state)agency requires a permit to be issued by that public agency unless otherwise designated. In addition to the permitting requirements mandated by statute,the trench safety regulations require that all excavators,whether public or private,take specific precautions to protect the general public and prevent unauthorized access to unattended trenches. Accordingly,unattended trenches must be covered,barricaded or backfilled. Covers must be road plates at least 3/4"thick or equivalent; barricades must be fences at least 6' high with no openings greater than 4"between vertical supports;backfilling must be sufficient to Pg.8/10 eliminate the trench. Alternatively, excavators may choose to attend trenches at all times, for instance by hiring a police detail, security guard or other attendant who will be present during times when the trench will be unattended by the excavator. The regulations further provide that local permitting authorities,the Department of Public Safety,or the Division of Occupational Safety may order an immediate shutdown of a trench in the event of a death or serious injury;the failure to obtain a permit; or the failure to implement or effectively use adequate protections for the general public. The trench shall remain shutdown until re-inspected and authorized to re- open,provided,however,that excavators shall have the right to appeal an immediate shutdown. Permitting authorities are further authorized to suspend or revoke a permit following a hearing. Excavators may also be subject to administrative fines issued by the department of Public Safety for identified violations. For additional information please visit the Department of Public Safety's website at www.mass.gov/dps Summary of 1926 CFR Subpart P- OSHA Excavation Standard This is a worker protection standard,and is designed to protect employees who are working inside a trench. This summary was prepared by the Massachusetts Division of Occupational Safety and not OSHA for informational purposes only and does not constitute an official interpretation by OSHA of their regulations, and may not include all aspects of the standard. For further information or a full copy of the standard go to www.osha.gov. • Trench Definition per the OSHA standard: o An excavation made below the surface of the ground, narrow in relation to its length. o In general,the depth is greater than the width,but the width of the trench is not greater than fifteen feet. • Protective Systems to prevent soil wall collapse are always required in trenches deeper than 5',and are also required in trenches less than 5' deep when the competent person determines that a hazard exists. Protection options include: o Shoring. Shoring must be used in accordance with the OSHA Excavation standard appendices,the equipment manufacturer's tabulated data,or designed by a registered professional engineer. o Shielding(Trench Boxes). Trench boxes must be used in accordance with the equipment manufacturer's tabulated data,or a registered professional engineer. o Sloping or Benching. In Type C soils(what is most typically encountered)the excavation must extend horizontally 1-1/2 feet for every foot of trench depth on both sides, 1 foot for Type B soils,and 3/4 foot for Type A soils. o A registered professional engineer must design protective systems for all excavations greater than 20'in depth. • Ladders must be used in trenches deeper than 4'. o Ladders must be inside the trench with workers at all times, and located within 25'of unobstructed lateral travel for every worker in the trench. o Ladders must extend 3'above the top of the trench so workers can safely get onto and off of the ladder. • Inspections of every trench worksite are required: o Prior to the start of each shift, and again when there is a change in conditions such as a rainstorm. o Inspections must be conducted by the competent person(see below). • Competent Person(s)is: o Capable(i.e. trained and knowledgeable) in identifying existing and predictable hazards in the trench,and other working conditions which may pose a hazard to workers,and Pg.9/10 o Authorized by management to take necessary corrective action to eliminate the hazards. Employees must be removed from hazardous areas until the hazard has been corrected. • Underground Utilities must be: o Identified prior to opening the excavation(e.g.,contact Digsafe). o Located by safe and acceptable means while excavating. o Protected, supported,or removed once exposed. • Spoils must be kept back a minimum of 2' from the edge of the trench. • Surface Encumbrances creating a hazard must be removed or supported to safeguard employees. Keep heavy equipment and heavy material as far back from the edge of the trench as possible. • Stability of Adjacent Structures: o Where the stability of adjacent structures is endangered by creation of the trench,they must be underpinned,braced,or otherwise supported. o Sidewalks, pavements,etc. shall not be undermined unless a support system or other method of protection is provided. • Protection from water accumulation hazards: o It is not allowable for employees to work in trenches with accumulated water. If water control such as pumping is used to prevent water accumulation,this must be monitored by the competent person. o If the trench interrupts natural drainage of surface water,ditches,dikes or other means must be used to prevent this water from entering the excavation. • Additional Requirements: o For mobile equipment operated near the edge of the trench, a warning system such as barricades or stop logs must be used. o Employees are not permitted to work underneath loads. Operators may not remain in vehicles being loaded unless vehicles are equipped with adequate protection as per 1926.601 (b)(6). o Employees must wear high-visibility clothing in traffic work zones. o Air monitoring must be conducted in trenches deeper than 4'if the potential for a hazardous atmosphere exists. If a hazardous atmosphere is found to exist(e.g.,02<19.5%or>23.5%, 20%LEL, specific chemical hazard),adequate protections shall be taken such as ventilation of the space. o Walkways are required where employees must cross over the trench. Walkways with guardrails must be provided for crossing over trenches>6'deep. o Employees must be protected from loose rock or soil through protections such as scaling or protective barricades. Pg.10/10 • Building Permit Caluclation PROJECT: Alumnae House Renovation ADDRESS: 33 Elm Street, Northampton, MA,01060 ARCHITECT: KPMB Architects SHAWMIIT PROJECT#: 171336 6csLJn ntnl Cans46ckon CSI# Trade Final Pricing 024100 DEMOLITION $873,180 028000 ABATEMENT $329,063 033000 CONCRETE $532,834 042000 MASONRY $646,583 050393 REFURBISH METAL LOCKERS $27,434 051000 STRUCTURAL STEEL $640,913 055000 MISC. METALS $741,373 057000 ORNAMENTAL BRASS RESTORATION $46,000 061000 ROUGH CARPENTRY $613,322 062000 EXTERIOR SIDING&FINISH CARPENTRY $250,594 064000 MILLWORK $424,064 064400 MILLWORK SALVAGE&RESTORATION $466,363 071000 WATERPROOFING $81,335 072000 SPRAY-APPLIED FOAM INSULATION $93,650 075000 ROOFING $548,699 078100 FIREPROOFING $3,900 079200 JOINT SEALANTS $32,000 081000 DOORS,FRAMES&HARDWARE $161,462 081116 ALUM-CLAD WOOD WINDOWS&DOORS $245,230 083000 WOOD DOOR RESTORATION $65,840 084100 INTERIOR STOREFRONT $142,465 085123 STEEL WINDOW&DOOR RESTORATION $147,977 085200 WOOD WINDOW RESTORATION $90,140 088000 GLASS&GLAZING $21,635 092000 DRYWALL $967,343 092300 PLASTER $154,700 093000 TILE $298,545 095100 ACOUSTICAL CEILINGS $90,900 096000 CARPET/RESILIENT FLOORING $255,789 096400 WOOD FLOORING $66,327 097723 ACOUSTIC WALL PANELS $54,500 099000 PAINTING $245,918 099600 STRIP&POWDER COAT METAL $14,700 100000 SPECIALTIES $44,700 114000 FOOD SERVICE EQUIPMENT $170,860 122000 WINDOW TREATMENT $71,046 123640 MARBLE SALVAGE&REUSE $20,690 142000 ELEVATOR $161,850 210000 FIRE PROTECTION $212,267 220000 PLUMBING $506,589 230000 HVAC $3,793,331 260000 ELECTRIC&LIGHT FIXTURE REST. $2,263,571 310000 EARTHWORK $817,563 316200 DRILLED MICRO PILES $150,863 Total Construction Cost: $17,588,108 Building Permit Fee(Renovation)_$7 per$1000 Building Permit+Trench Fee= $123,117