09-007 426 KENNEDY RD BP-2021-1437
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block: 09-007 CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: BUILDING PERMIT
Permit# BP-2021-1437
Project# JS-2021-002391
Est.Cost:
Fee: $40.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Group: OLDE HADLEIGH HEARTH & HOME CENTER 98784
Lot Size(sq.ft.): 190357.20 Owner: SALZ SCHUYLER
Zoning: RR(100)/WSP(100)/ Applicant: OLDE HADLEIGH HEARTH & HOME CENTER
AT: 426 KENNEDY RD
Applicant Address: Phone: Insurance:
119 WILLIMANSETT ST (413) 538-9845 WC
SOUTH HADLEYMA01075 ISSUED ON:6/2/2021 0:00:00
TO PERFORM THE FOLLOWING WORK:WOODSTOVE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
I• 11 •
Certificate of Occupancy Signatur . yyQQ •
FeeType: Date Paid: Amount:
Building 6/2/2021 0:00:00 $40.00
212 Main Street,Phone(413)587-1240,Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
(I-
/4,, ,„ . ' City of Northampton
E r 3 1,, Massachusetts �.� t
r
' ` DEPARTMENT OF BUILDING INSPECTIONS tC
•tta' ° .�.1e 212 Main Street • Municipal Building
`� ::,"'*f Northampton, Mh 01060 s 14`.
APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION C ?
• sCR —00 7 , 4),,,
Property Information 3,4,M4,44,
/
Owners Name: ��'�,I�U�r k� c and K l-i e. S a Z r��O7,cT'ONs
r
i
Address: (/2.(9 Ke nil'dv 12d.,_,_, LePdf 0JC53
(No.) (Street Address)
qa�-L3q-C�s$�
Phone: 11: 97g- 8(tY- Email: KKcci-i•e,sa_lz ? 0n-mail . cc".
Owners Signature: Date: S lZ /Z l
Contractor's Information ((ffApplicable)
Name: c‘cte 4 il,e,_\_, ft co- fi- 1--c e. Phone: i((3 .5•3s 4. s.15
Construction Supervisor's License #: ess L'oe,S1 Y`I Expiration: 'I• li- )
Home Impr. Contractor License #: tii I , Expiration: 9• I P- a I
Stove Information
Type of Fuel (check all that apply): Wood V Pellet Coal
Location: L I.,\.tis (Z0 G,,.,, Freestanding 1/' Insert
Manufacturer: r-Ac.,l Model: I Soc.) U -3
.. _ _N --FOR BUILDING DEPA.RTMENT USE ONLY--
Permit# 12 t-/ Date Applied: Total all Fees: $ t4i
II
Building Official: & ✓U;, �k 5 Date Issued: Co Z' ZOZI
(Prim) / il�
Signature of Building Official: /
The Commonwealth of Massachusetts
--- —_ Department of lndustrkl Accidents
.kr . �,-_!I Office of Investigations
jI
600 Washington Street
Boston,MA 02111
www.mass,gov/dia
Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers
Annli ant Information Please Print Lesibly
Name(BusinesstDcganiution/indivtdual) )( h Ht{,, 4 f i CLf't t UiC.
Address: I)vl W i l IlMa tSe4I- <C-te
City/State/Zi 1, Phone# a 5'� q%96
Are you an employer?Check t appropriate box:
I,LD I am a employer with •Y 4. 0 I am a general contractor and I Type of project(required);
employees(R111 and/or part-ttme).e have hired the sub-contractors t5• 0 New construction
2,❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. []Remodeling
ship and have no employees These sub-contractors have 8. 0 Demolition
worming for me in any capacity. employees and have workers' 9. Building addition
[No workers'comp,insurance comp,insurance,= 0 8
required,] 5. 0 We are a corporation and its 10.0 Electrical repairs or additions
3,❑ I am a homeowner doing ell work officers have exercised their 11.❑Pltunbing repairs or additions
myself.[No workers'comp, right of exemption per MOL 12.0 Roof repairs
insurance required.)t c. 152,§1(4),and we have no 13.❑Other
employees.[No workers'
i comp,insurance required.)
'Any applicant War checks box 01 must also nil out tba seetioe'below showing their wariest'eoenpoustion policy intbrmation.
t Homeowners who submit this affidavit indicating they are dotes aA wodt and tics kite outside teetracttors must submit a:saw ditdsvi:Indicating such,
;Contractors that check this box must attached an add kioesl sheet showing the n nss of the sob-contrectors and stun whether or not thou entities have
employees, If the sub-contractors have er>zployees,they must provide their warkiars'coup.policy cumber,
I am an employer that is providing workers'compensation buurante for my,employees, Below is rite policy and Job site
Information.
Insurance Company Name:•TQyettgs
Policy#or Self-ins.Lic,#;U24"&..)1 ICA 63 Expiration Date:01 )la IQ
Job Site Address: City/State/Zip:
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of M(JL c. 152 can lead to the imposition of criminal penalties of a
fine up to S1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to S250,00 a day against the violator, Be advised that a copy of this statement may be forwarded to the Office of
investigations of the DIA for insurance coverage verification.
I do hereby certil,under thepaint¢nd penalties of perjury that fee information provided above La true and correct.
Signature: ��`-`" C� �// `- Date: -l'd • i 5• Au_"
Phone#:
Official icial use only. Do not write In this area,to be completed by city or town official i
City or Towns Permit/License#
Iuuing Authority(circle one):
1.Board of Health 2.Building Department 3.City/Town Clerk 4,Electrical Inspector S.Plumbing Inspector
6,Other
Contact Person: , , Phone#:
Conlnilortwealtli of Massachusetts i:.:
',Division of Professional LiC:ensure
{
t- :hoard ofi Buiiding . f fan an Standards
CQnstruc , . p•' specialty .,.
CSSL-09878 4 ; . . ;® ire-se 04/28/2023
�} M" t. t J .ajMil(�I ivr ter
.
ill
t, n
,`rixY Ey 7 - - 71
r�
::;.,,:,-,..,
i .
.'., yX F 'P.y f ti 4.
Office of Consumer Affairs and Business Regulation
1000 Washingt n Street Suite 710
Boston, M , ckhusetts 02118
Home Improveme: Ce tractor Registration
uiI. ;� Type: Corporation
i Registration: 148198
OLDS HADLEIGH HEARTH&HOME CENT- Tt1ra Expiration: 09/12/2021
119 WILLIMANSETT STRETT RT 33
S.HADLEY,MA 01075 _;'
7Cf "�'
Update Address and Return Card.
I 0 20M•05/17 ..
F I _.
Office of Consumer Affairs&Business Regulation
HOME IMPRO MENT CONTRACTOR Registration valid for Individual use only
TYP 'Corooration before the expiration date. If found return to:
s Exolratlorl Office of Consumer Affairs and Business Regulation
-09/122021 1000 Washington Street -Suite 710
OLDE HADLEIG'I`lA f'5ME CENTER,INC. Boston,MA 02118
MATTHEW D.COX �% ,� ����
119 WILLIMANSET�T TII T�f RT 33 ,ot-�arC,/7a-e4"-k- CC.
S.HADLEY,MA 01075 Undersecretary Not valid WI out signature
JOtu l F 500 V3
Oslo
e Catalytic Wood Heater
Classic and Clean Face Models
v,
O
O
C Installation and Operating Instructions
0 W for the United States and Canada
Atrom • The JOtul F 500 V3 wood stove is listed
: to burn solid wood only. Do not burn
e� • fir s any other fuels.
'. �y � , • Read this entire manual before you
:al ,.r install and use this appliance.
` ■ Save these instructions for future
reference and make them available to
anyone using or servicing this wood
Classic heater.
■ This wood heater contains a catalytic
combustor that requires periodic
inspection and repair for proper
operation. See this manual for
specific maintenance information.
It is against federal regulations to
operate this wood heater in a manner
inconsistent with the operating
W} y
instructions in this owner's manual,or
if the catalytic element is deactivated
or removed.
Clean Face
004 •
Une version francaise de ce manuel est disponible
JOTUC aupres de votre revendeur et sur le site www.jotul.ca.
F500 V3 Oslo Oct 2o2o
Table of Contents Standards
The J0tul F 500 V3 Oslo solid fuel heater has been tested and
Combustion Specifications, listed to ANSI/UL 1482-11 in the U.S.and
Building Codes, ANSI ULC-5627-M20 in Canada.
Safety Notices 3 Certified Safety Tests performed by
Intertek Testing Services,Middleton,WI U.S.A.
.. Installation
1.1 Assembly before Installation 4 Manufactured by
2. Chimney and Connector Requirements 10tul North America,Inc.
2.1 chimney Connector 4 55 Hutcherson Drive
2.2 General Requirements 4 Gorham,Maine 04038,U.S.A.
2.3 Masonry Chimneys 5
2.4 Prefabricated Chimneys 5
2.5 Chimney Height 5 This heater meets the 2020 U.S.
2.6 Wall Pass-through 6 Environmental Protection Agency's
3. Connecting to the Chimney emission limits for wood heaters
31 Masonry Chimney Thimbles 6 manufactured after May 15,2020.
3.2 Hearthmount into a Masonry Fireplace 6
3.3 Prefabricated Chimneys 7
4. Clearances to Combustibles WARNING
41 Floor Protection 7 THIS WOOD HEATER HAS A MANUFACTURER-
4,2 Clearances to Walls and Ceilings 7 SET MINIMUM LOW BURN RATE THAT MUST
4.3 Using Shields to reduce Clearances 7-8 NOT BE ALTERED. IT IS AGAINST FEDERAL
4.4 Alcove Installation 8 REGULATIONS TO ALTER THIS SETTING
4.5 Mobile Home Installation 8 OR OTHERWISE OPERATE THIS WOOD
5. Operation HEATER IN A MANNER INCONSISTENT WITH
5.1 Combustion Efficiency 9 OPERATING INSTRUCTIONS IN THIS MANUAL.
5.2 CO Emissions 9
5.3 Wood Fuel and Performance 9-to
5.4 Stove Control-Functions and Settings to This manual describes the installation and
5.5 Catalytic Combustor Monitor to-rt operation of the 1Otul F 500 V3 catalytic equipped
5.6 Break-in Procedure it wood heater.This heater meets the 2020 U.S.
5.7 Starting and Maintaining a Fire 11-12
5.8 Creosote Formation and Removal 12 Environmental Protection Agency's crib wood
5.9 Adding Fuel 13 emission limits for wood heaters sold after May
15,2020.Under specific test conditions,this
heater has been shown to deliver heat at rates
6. Maintenance ranging from t
6.1 Annual Stove Inspection 13 g g 3,o0o to 37,00o Btu/hr.
6.2 Ash Removal 13
6.3 Chimney System 13
6.4 Enamel Care 13 NOTE:It is normal for a new,painted stove
6.5 Glass Care/Glass Replacement 14 to emit odor and smoke during initial fires,
6.6 Gaskets 14 depending upon temperatures over time.This is
caused by the curing of high temperature paint
7. Accessories 15 and manufacturing materials.This condition
8. Illustrations can be alleviated by opening a window or door
Figures 16-21 to provide additional ventilation.See Break-in
Clearance Chart and Diagrams 22-23 Procedure,Sect.5.6 for details.
9. Appendix
A.Catalytic Combustor Maintenance 24 NATIONAL We suggest that our woodburning hearth
FIREPLACE
Catalytic Combustor Replacement 25-26 INSTITUTE products be Installed and serviced by
B. Alternate Floor Protection �7 I NFI I professionals who are certified in the U.S.
by the National Fireplace Institute*(NFI)as
10.Warranty z8_ o NFI Woodburning Specialists or who are
3 certified in Canada by 0
CERTIFIED Wood Energy Technical Wood Ener9r
rtsinIng
...., ,w„a Training(WETT). r cnnka�t,,,
,wy ..
2
F 500 V3 Oslo Oct.2020
Combustion Specifications Safety Notices
Heat Output Range:' 13,200 to 37,00o BTU/hr.(3.g-io.8 kW) • BURN SOLID,NATURAL WOOD FUEL ONLY.DO NOT BURN ANY
Max. Heat Output: 70,00o BTU/hr. OTHER FUEL.
Heating Capacity:2 Up to 2300 sq. ft. • DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE.DO NOT
Maximum Burn Time:2 Up to 12 hours BURN GARBAGE OR FLAMMABLE FUELS.
EPA Efficiency:3 HHV: 78.4o% LHV: 84.73% • DO NOT USE A GRATE OR ELEVATE THE FIRE.BUILD THE FIRE
CO Emissions:4 .5o g/min. DIRECTLY ON THE HEARTH.
Pariculate Emissions:5 5o g/hr. • IF THIS ROOM HEATER IS NOT PROPERLY INSTALLED,A HOUSE
Fuel: Up to 24"Logs(609 mm) FIRE MAY RESULT.TO REDUCE THE RISK OF FIRE,FOLLOW THE
INSTRUCTIONS IN THIS MANUAL.FAILURE TO FOLLOW THESE
Heat Output Range results are determined during specific emis- INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,BODILY
sions tests established by the EPA. INJURY,OR LOSS OF LIFE.
The Maximum Heat Output value is representative of a more • CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC-
frequent re fueling cycle than specified in the EPA High Heat TIONS AND INSTALLATION INSPECTION REQUIREMENTS IN
Output test method. YOUR AREA.
2 Heating Capacity and Maximum Burn Time will vary depending
on design of home,climate,wood type and operation. • ANY EXISTING CHIMNEY SYSTEM MUST BE INSPECTED BEFORE
3 INSTALLATION OF THIS APPLIANCE.
EPA Validated Efficiency:
High Heat Value and Low Heat Value efficiencies are determined • DO NOT CONNECT THIS STOVE TO ANY AIR DISTRIBUTION
per the CSA B415.1-io test method.The difference between the DUCT OR SYSTEM.
HHV and LHV is how the energy in the exhaust gas water vapor . EXTREMELY HOT WHILE IN OPERATION! KEEP CHILDREN,
is accounted for. CLOTHING,AND FURNITURE AWAY.CONTACT WILL CAUSE SKIN
LHV efficiency assumes all the water vapor in combustion gases BURNS.USEACHILDGUARDSCREENTOPREVENTACCIDENTAL
was condensed and the heat from such was recovered and CONTACT BY SMALL CHILDREN.
transferred to the dwelling.HHV calculations do not assume all
water vapor is condensed,therefore the HHV value is less than • INSTALL CO SMOKE DETECTORS IN THE LIVING AREA AND
the LHV value. BEDROOMS OF YOUR HOME.TEST THEM REGULARLY AND
4 Carbon Monoxide Emissions rate results from
INSTALL FRESH BATTERIES TWICE ANNUALLY.
Test Method CSA 8475.i-io. WHEN INSTALLED IN THE SAME ROOM AS THE STOVE,ASMOKE
OR CARBON MONOXIDE DETECTOR SHOULD BE LOCATED AS
S Particulate Emissions rate is obtained using
EPA Test Method 28-R. FAR FROM THE STOVE AS POSSIBLE TO PREVENT THE ALARM
SOUNDING WHEN ADDING FUEL.
• Avoid creating a low pressure condition in the room where
EPA Certified Emissions Tests pFs,, the stove is operating.Be aware that operation of an exhaust
performed by ® fan or clothes dryer can create a low pressure area and conse-
PFS TECO,Portland,OR U.S.A. quently promote flow reversal through the stove and chimney
USsystem.In some cases,the optional Outside Air Kit#154335
can be used to alleviate this condition.The chimney and build-
ing,however,always work together as a system-provision of
outside air,directly or indirectly to an atmospherically vented
appliance will not guarantee proper chimney performance.
Consult your local Jotul authorized dealer regarding specific
installation/performance issues.
Check Building Codes
• J0tul strongly recommends that this stove be installed by
Your city,town,county or province may require a building a professional solid fuel technician,or that you consult one
if you do the work yourself.Also,consult your insurance
permit to install a solid fuel burning appliance. company regarding any other specific requirements.
In the U.S.,the National Fire Protection Association's See Sect.5.0 of this manual for important information
Code,NFPA zit,Standards for Chimneys,Fireplaces,Vents regarding the safe,proper,and most efficient operation
and Solid Fuel Burning Appliances,or similar regulations,
may apply to the installation of a solid fuel burning of your stove.
appliance in your area.
Always follow the guidelines presented in this manual
Always consult your local building inspector or authority when installing,operating,and maintaining this
having jurisdiction to determine what regulations apply appliance and make this manual available to anyone
in your area. using or servicing the stove.
3
F 500 V3 Oslo Oct.2o2o
Fig.3. Chimney height; 3/2/ro Rule.
8. Illustrations •
Fig.ia
281/q" �
NI III 11111
"' 7ao mm 1Ei�■ At least 2feet
At least 3feet illEf lA
•rni
801, ,
(-------Nitisl
.... ..... - -- _
P■O.
wri_•
Ir
--1111110, sill
a' 'ilillr _ ro feet
f7��gl� t gg
i• l.!Uli li . ii ill r —_
_ ._ T.
_ Flue liner
-- Wood stud 2"clearance
from chimney wall ,,� ,
Pleader Alir���1
Fig.ib Thimble assembly: �� 11 ."11 /�'
if of brick separation from \ \f _ /
243/4" clay liner to combustibles '% '�#� ///�
629mm a � �� � �
Fireday liner 5/8"min. k"����' /
` or equivalent � /
fit
k `:\./ /
L. ,..— _ � sill/support �\ \ il�/�
°N° Chimney wall
�I�"�\ '�
�, r Ili
''''''JIEJ
l
N
4.II !i. LL._ t 4vo...,,ee
...
tr Fig.4. Masonry chimney penetration.
16 r/4"
420 mm Fig.5. Chimney thimble components.
Connector pipe shall be flush
Fig.2. Chimney connector assembly with the inside of the flue they ,--- i/y,,
'1.1141. s
IIIII Stove pipe connector �4
tnr7p , t'rit�i4t ) •f I ��h
rt}.rt??i4t..;rj'r.L' r��4�
///�/i, r s I
Toward Stove Flue Gas Direction Thimble 7-4
LJ Flue thel
, / 7
7.,
16
F 500 V3 Oslo Oct.2020
JOtul F 500 V3 Clearances
These clearance specifications result from safety testing by Intertek Testing Services,Inc. Use the table below
together with the diagrams on the facing page to determine the clearances for your particular installation.
• Stove clearances result from tests that include the chimney connection in the system.
• Chimney connector clearances listed separately are from NFPA 211,independant of the stove position.
Stove Clearance Unprotected surface Protected surface*
Side Rear Corner** Side Rear Corner'
Stove-no heat shield 14"A i8"B 13"C 6"D i2"E g"F
Single-wall pipe 355mm 46omm 33omm t5omm 3oomm 23omm
Stove with rear heat shields 14"A to"G 9"F 6"D 10"G g"F
and single-wall pipe 355mm 255mm 230mm 15omm 255mm 230mm
Stove with rear heat shield 14"A 6"D 9"F 6"D 6"D 6"D
and connector shields 355mm 15omm 23omm i5omm i5omm i5omm
or double-wall pipe
Vertical Connector Clearance (X)
Unprotected surface Protected surface*
Single wall pipe 18" / 46omm 12"/3oomm X
Single-wall pipe 6" / i5omm 6" / i5omm
with connector shields
Double-wall pipe 6" / i5omm 6" / i5omm Y
Horizontal Connector Clearance (Y)
Unprotected surface Protected surface*
Single-wall pipe 18" 460mm 12" 3oomm
ir 1
Double-wall pipe 6" i5omm 6" i5omm
Fireplace Mantle and Trim Clearance
Stove Side to Side Trim- t"thick or less: 12" 3oomm
Stove Top to Upper Trim-i"thick or less: i6" 4tomm
Stove Top to Mantle-12"maximum depth: 3o" 765mm
Mantel and Trim clearances may be reduced by 50%following protection construction methods specified by NFPA 2ft
Standards for Chimneys,Fireplaces,Vent and Solid Fuel Burning Appliances or similar local regulations.
*Protection specified per NFPA 271.
**Use of the left side load door is prohibited in Alcove and Corner installations.
Use Side Door Lock Kit#75585o to permit installation.
22