PHEC-2296 66 Chestnut St Ext code guide66 Chestnut St Ext Leeds, MA 01053
All specifications used above, and
home built per plans 55
Refrigerator Energy Star certified
Dishwasher Energy Star certified
Washer Energy Star certified
Dryer Energy Star certified
Projected Rating Results
Scenario HERS Index Score
Windows & Glass Doors U-Factor = .28
Maximum blower door test of 3 ACH50Air Barrier & Air Sealing Details
Lighting 100% LED Bulbs
Heating Equipment 96% AFUE Furnace W/ ECM
Cooling Equipment 13 SEER Central AC
Some ductwork located outside of envelope
Ventilation System Energy Recovery Ventilator (ERV)
Water Heater .95 UEF On-Demand
Lighting & Appliances
Cathedral Ceilings
Stretch Code Specifications
Project Address
HERS Rater Jared Kain-Woods
Insulation & Air Sealing
R-38 insulation
Ducts
Projected Ventilation CFM 65
Slab Uninsulated
Foundation Walls R-10 fire rated foamboard
Floors R-32 dense cellulose
Blockers & Runners R-21 insulation
Mechanical Equipment
Exterior Walls R-20 dense cellulose
Flat Ceilings R-60 loose cellulose (16" deep)