Loading...
CARL Dawson 77 brookwood dr noho 1-14-21-LayoutTo the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expense and responsibility. The contractor shall verify all dimensions and enclosed drawing. YOUR COMPANY NAME HERE is not liable for errors once construction has begun. While every effort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. P-1P-1 LAURA'S ARCH DRAFTING AND DESIGN DRAWING PREPARED FORDAWSON RESIDENCEDAWSON RESIDENCE77 BROOKWOOD DR 77 BROOKWOOD DR NORTHAMPTON MA NORTHAMPTON MA ADDITION ADDITION ELEVATIONSELEVATIONS1/4"=1'0"1/4"=1'0"DRAWINGS PROVIDED BYLAURA'S ARCHITECTURAL DRAFTING AND DESIGN220 TAYLOR ST. GRANBY, MA 01033 413-467-2899ADDITION ADDITION ADDITION ADDITION ADDITION ADDITION SHEET: SCALE: DATE: 3/2/2021 ADDITION ADDITION ADDITION ADDITION ADDITION ADDITION EXISTING EXISTING ADDITION ADDITION ADDITION ADDITION EXISTING EXISTING EXISTING EXISTING DNDN SB3018B30SB4221 SB4221 LSB36RSB36 ChefSeries Dishwasher B24R B24R B12R B24RB24RB12R B27SB3018B30SB4221 SB4221 LSB36RSB36 ChefSeries Dishwasher B24R B24R B12R B24RB24RB12R B27DCW2436RW3936W3519W1236R W3024 W3636 W2436RW29369080 80682050DH4050FX2050DH30683042DH3042DH 2436DH 3068 3046DH3046DH3046DH3046DH 3050DH3050DH30681609030683046DH3046DH26683046DH3046DH246826682668 3068 3636DC 6068 2446DH 2446DH 3068 20683668 DN DN DN SD SD SD CO/SD CO/SD CO/SD HD E12E12 Elevation 12 E13E13 Elevation 13 3'-6"15'-6"7'-6"9'11'11'9'11'-6"11'-6" 13'-2"7'-6"2'-4"10'-6"9'-2"2'-4"10'-6"9'-2"12'-3"5'-9"6'-8"3'-2"11'18'6'4'-1" 3'-8"3'-1"11'-7"11'-7"4'3'-6"11'-6" 3'-6" 17'-1"6'-1"15'-3"4'7'-10"5'3'8'-3"10'-2"2'9'-3"11'-7"11'-7"16'-7" 12'-1"22'2'40'74'-6" 23'33'-6"18'12'22'6'46'22'24'74'-6" 40'11'-6"23' MASTER BEDROOM MASTER BEDROOM WALK WALK ININ CLOSETCLOSET BEDROOM BEDROOM BEDROOM BEDROOM KITCHEN KITCHEN DINING ROOM DINING ROOM NEW NEW LIVING ROOM LIVING ROOM (PREVIOUSLY GARAGE )(PREVIOUSLY GARAGE ) REMOVE WALL REPLACE W/ LVL BEAM ARCHED OPENING CATHEDRALCATHEDRAL CEILING CEILING EXISTING DECK EXISTING DECK 4'' POURED CONCRETE FLOOR 4000 PSI ROOF TRUSSES @ 24'' OC 11'0'' CEILING HEIGHT NEW GARAGE ADDITIONNEW GARAGE ADDITION 7'5'' CEILING HEIGHT V.I.F. 2X8 RAFTERS @ 16'' OC 2X10 CEILING JOISTS @ 16'' OC NEW MASTER BATH NEW MASTER BATH LINEN FUTURE W/D LOCATION SISTER EXISTING RAFTERSW/ NEW 2X8 RAFTERS @ 16'' OC NEW CLOSED CELL SPRAY FOAM INSULATION IN RAFTERS R-38 NEW COVERED PORCH NEW COVERED PORCH 2X8 RAFTERS @ 16'' OC 2X10 CEILING JOISTS @ 16'' OC 3-2X10 HEADER 3-2X10 HEADER REMOVE EXISTING GARAGE DOOR ADD NEW TRIPLE D/H WINDOW VERIFY CLOSET OVER STAIRS TO REMAIN P-2P-2FLOOR PLANFLOOR PLANDRAWING PREPARED FORDAWSON RESIDENCEDAWSON RESIDENCE77 BROOKWOOD DR 77 BROOKWOOD DR NORTHAMPTON MA NORTHAMPTON MA 1/4"=1'0"1/4"=1'0"DRAWINGS PROVIDED BYLAURA'S ARCHITECTURAL DRAFTING AND DESIGN220 TAYLOR ST. GRANBY, MA 01033 413-467-2899SHEET: SCALE: DATE: 3/2/2021 S S 30683016RS3068 UP UP CO/SD E1E1 Elevation 1 E5 P-1 E5 P-1Elevation 5 E12E12 Elevation 12 E14E14 Elevation 146'6'6'16'6'6'-6"6'-6"6'-6"5' 9'9'11'11'22'2'40'8'32'6'12'46'22'24'11'-6"22' 74'-6" 23'33'-6"18' 7'-6"15'-6" 74'-6" 40'11'-6"23' 11'-6"11'-6" UNEXCAVATED UNEXCAVATED PROVIDE M.O. FOR 16'0'' OH DOOR PROVIDE M.O. FOR 16'0'' OH DOOR PROVIDE M.O. FOR 9'0'' OH DOOR PROVIDE M.O. FOR 30'' DOOR EXISTING FOUNDATIONEXISTING FOUNDATION 2X6 PT FLOOR JOISTS @ 16'' OC NEW 2X10 FLOOR JOISTS @ 16'' OC 2X10 LEDGER BOLTED BOTH SIDES R-30 INSULATION 3/4'' T&G ADVANTECH MATCH EXISTING FLOOR HEIGHTS EXISTING CONCRETE FLOOR TO REMAIN 2X8 FLOOR JOISTS @ 16'' OC 2X8 FLOOR JOISTS @ 16'' OC BEAM POCKET BEAM POCKET 4'' POURED CONCRETE FLOOR 3500 PSI 8'' POURED CONCRETE WALLS W/ 18'' X 10'' CONT'D FOOTING 3 1/2'' LALLY COLUMN 8'' POURED CONCRETE WALLS W/ 18'' X 10'' CONT'D FOOTING 12'' X 48'' CONC. COLUMNS W/ BIGFOOTS 3-2X8 PT DROP BEAM 2X8 PT LEDGER BOLTED 8X8X12 CONCRETE BLOCKS TO FILL IN EXISTING GARAGE DOOR TO BE REMOVED OPENING PROVIDE OPENING INTO NEW FOUNDATION VERIFY LOCATION AND SIZE LVL ENGINEERED CARRYING BEAM AS REQ'D. P-3P-3DRAWING PREPARED FORDAWSON RESIDENCEDAWSON RESIDENCE77 BROOKWOOD DR 77 BROOKWOOD DR NORTHAMPTON MA NORTHAMPTON MA 1/4"=1'0"1/4"=1'0"DRAWINGS PROVIDED BYLAURA'S ARCHITECTURAL DRAFTING AND DESIGN220 TAYLOR ST. GRANBY, MA 01033 413-467-2899SHEET: SCALE: DATE: 3/2/2021FOUNDATION PLANFOUNDATION PLANPINNED AND SEALED TO EXISTING 11'APPROX GRADE 2X6 PT FLOOR JOISTS @ 16" OC VINYL RAILING AND BALUSTERS TYP CONT'D RIDGE VENT VINYL SIDING W/ HOUSEWRAP 18"X10" CONT'D FOOTING W/ 2X4 KEYWAY 5 VERIFY 12 8" POURED CONCRETE FROST WALLS 5/4X6 DECKING 4" POURED CONCRETE FLOOR 4000 PSI 2X6 PT SILL W/ SEALER W/ 1/2"X12" ANCHOR BOLTS @ 6' OC ROOF TRUSSES @ 24" OC TO BE ENGINEERED BY MANUF. 2-2X10 HEADERS 2-2X6 TOP PLATES 3-2X8 DROP PT BEAM 2X6 EXT STUDS @ 16" OC 12X48 CONC. COLUMNS W/ BIG FOOTS 1/2" CDX WALL SHEATHING 5/8" FC DRYWALL ON CEILING AND WALLS DEC. LOAD BEARING COLUMNS 3-2X10 CONT'D HEADER 2X8 RAFTERS @ 16'' OC 2X10 RIDGE BOARD 2X10 CEILING JOISTS @ 16'' OC ASPHALT SHINGLES W/ 15# FELT 1/2" CDX SHEATHING 36" ICE AND WATER BARRIER 6" FASCIA W/ 12" VENTED SOFFIT VINYL SOFFIT 5 VERIFY 12 2-2X6 TOP PLATES R-38 INSULATION NEW 2X10 FLOOR JOISTS @ 16" OC 2-2X10 HEADERS 3/4" T&G ADVANTECH 1/2" DRYWALL INT FINISH NEW 2X8 CEILING JOISTS @ 16'' OC EXISTING RAFTERS @ 16'' OC TO REMAIN SISTER EXISTING RAFTERS W/ 2X10 @ 16'' OC W/ R-38 INSULATION R-38 INSULATION 6 MIL POLY ABOVE EXISTING CONCRETE FLOOR EXISTING FOUNDATION EXISTING ROOF TO REMAIN REPLACE EXISTING RIDGE WITH NEW LVL BEAM AS REQ'D. EXISTING WALLS TO REMAIN W/ NEW R-15 INSULATION 7'-6"VERIFY R-30 INSULATION 2X10 RAFTERS @ 16" OC 2-2X6 TOP PLATES 2X12 RIDGE BOARD R-38 INSULATION 2X6 COLLAR TIES @ 32'' OC 30X30X12 CONC. PADS 3-2X10 CARRYING BEAM 5 +/- 2X6 PT SILL W/ SEALER W/ 1/2"X12" ANCHOR BOLTS @ 6' OC 2X8 FLOOR JOISTS @ 16" OC CONT'D RIDGE VENT R-21 INSULATION 2X6 EXT STUDS @ 16" OC 2-2X10 HEADERS 6" FASCIA W/ 12" VENTED SOFFIT 4" POURED CONC FLOOR 3500 PSI 1/2" CDX SHEATHING 12 3 1/2" LALLY COLUMNS ASPHALT SHINGLES W/ 15# FELT 3/4" T&G ADVANTECH 8" POURED CONCRETE WALLS 18"X10" CONT'D FOOTINGS W/ 2X4 KEYWAY 2X4 INT STUDS @ 16" OC DAMPPROOFING 1/2" DRYWALL INT FINISH APPROX GRADE 0 12 LVL BEAM TO BE ENGINEERED AS REQ'D 2X8 BOX SILL 72" ICE AND WATER BARRIER 1/2" CDX SHEATHING 2X10 CEILING JOISTS @ 16'' OC VINYL SIDING W/ HOUSEWRAP Elevation 13 P-4P-4DRAWING PREPARED FORDAWSON RESIDENCEDAWSON RESIDENCE77 BROOKWOOD DR 77 BROOKWOOD DR NORTHAMPTON MA NORTHAMPTON MA 1/4"=1'0"1/4"=1'0"DRAWINGS PROVIDED BYLAURA'S ARCHITECTURAL DRAFTING AND DESIGN220 TAYLOR ST. GRANBY, MA 01033 413-467-2899SHEET: SCALE: DATE: 3/2/2021CROSS SECTIONS CROSS SECTIONS LIVING ROOM 2X4 COLLAR TIES @ 16'' OC