38A-029 (4) 4 RUST AVE BP-2021-1231 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A-029 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2021-1231 Project# JS-2021-002051 Est.Cost: $21979.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: PIONEER VALLEY PHOTOVOLTAICS 111266 Lot Size(so. ft.): 4922.28 Owner: KARATSOREOS ILIA Zoning: URB(100)/ Applicant: PIONEER VALLEY PHOTOVOLTAICS AT: 4 RUST AVE Applicant Address: Phone: Insurance: 311 WELLS ST - SUITE B (413) 772-8788 Workers Compensation GREENFIELDMA01301 ISSUED ON:4/27/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 18 PANEL 6.57 KW SOLAR SYSTEM ON ROOF WITH INVERTER IN BASEMENT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signat � . TAR•f;; � 1 � FeeType: Date Paid: Amount: Building 4/27/2021 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner Department use only Cityof Northampton Status of Permit: p � r. Building Department1/ - Curb Cut/Driveway Permit 7 ff 212 Main Street 0 Sewer/Septic Availability ' Room 100 40(9/ vyater/Well Availability ,` • Northampton, MA 010bl0 ;., /Two Sets of Structural Plans phone 413-587-1240 Fax 413-5874 / Plot/Site Plans 0p6oCNs Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: � (} Map g1/1 Lot Qv/ Unit 4 Rust Ave, Northampton MA 01060 Zone Overlay District Elm St. District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Ilia Karatsoreos 4Rust Ave, Northampton MA 01060 Name(Print) Current Mailing Address: (509) 288-9854 See Attachment A Telephone Signature 2.2 Authorized Agent: Pioneer Valley Photovoltaics 311 Wells St. Greenfield, MA 01301 Name(Print) Current Mailing Address: ��d 413-772-8788 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 6,366 (a)Building Permit Fee 2. Electrical 15,613 (b)E o ConstructionstimatedTotal from Cost(6) f 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total= (1 +2+ 3+4+ 5) 21,979 Check Number l 3 q This Section For Official Use Only �a/„'a Building Permit Number. DateIssued: Signature: �1/UN y/; //g-g Building Commissioner/Inspector of Buildings Date buildingpermits @ pvsquared.coop EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) 4 RF 4 PV Squared Solar I www pvsquared coop Phone:413-772-8788 I Fax: 413-772-8668 s e 311 Wells St.,Ste. B I Greenfield,MA 01301 4,4 . P MA Elec. Lic.A13764 I MA HIC 140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering, civil engineering, electricians, construction supervisors, roofers, and their associated helpers. We are a company that values training and education. We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by the January 30, 2009 Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that have followed. We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Maya Fulford Installation Manager Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L:r.. _ , R:C tt 11 Rear L lM�l Building Height Bldg. Square Footage 1 r" j % Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES 0 IF YES, date issued: 1 IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES 0 IF YES: enter Book j Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO 0 IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition El Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors El Accessory Bldg. El Demolition El New Signs [CI] Decks [Ej Siding[D] Other[m] Brief Description of Proposed Installation of a 6.57 kW DC PV system with(18)panels Work: Alteration of existing bedroom Yes xx No Adding new bedroom Yes "" No Attached Narrative Renovating unfinished basement Yes xx No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a -OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Ilia Karatsoreos , as Owner of the subject property PV Squared (Pioneer Valley Photovoltaics) hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. See Attachment A See Attachment A Signature of Owner Date PV Squared as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Daniel Gomez Print Name 4/15/2021 Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Daniel Gomez Gonzalez License Number 43 Hatfield St. Northampton, MA 01060 CS-111266 Address Expiration Date 03/14/2023 Signature Telephone 413-772-8788 9. Registered Home Improvement Contractor: Not Applicable 0 Pioneer Valley Photovoltaics Cooperative Company Name Registration Number 311 Wells Street, Suite B, Greenfield, MA, 01301 140077 Address Expiration Date 413-772-8788 Telephone 09/15/2021 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes Z. No 0 DocuSign Envelope ID:FDD9B6AF-69B0-423A-80D7-C12E48BFF9AF Attachment A AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above, and I agree to pay the contract price according to the Terms of Payment. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. I hereby authorize Pioneer Valley PhotoVoltaics Cooperative to proceed with the above-referenced Project in accordance with this Agreement. I further authorize Pioneer Valley PhotoVoltaics Cooperative, or its designated representative, to obtain required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be used by Pioneer Valley PhotoVoltaics Cooperative for marketing purposes.A check for the First Payment is enclosed and I am returning this Agreement within 21 days of the Proposal date. Ilia Karatsoreos 2/17/2021 111:54 AM PST Printed Name Date DocuSigned by: LUt1. caratSOVtOS system OCC31976EC8F421 owner(s) Signature Title Proposal and Agreement#00016158 Page 7 of 13 Ilia Karatsoreos-February 16,2021 Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Constmet CS-111266 Expires: 0311412023 DANIEL GO(I EZ-GONZALEz 43 HATFIELD.`STREET NORTHAMPT044 MA 0:11060 (11, • •Commissioner dtsa '. ., Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card Registration: 140077 PIONEER VALLEY PHOTOVOLTAICS COOP Expiration: 09/15/2021 311 WELLS ST SUITE B GREENFIELD,MA 01301 SCA 0 zo►a-osrn Update Address and Return Card. /.,,,,,,a,..v, ,/, V. f .,..1 r!ii•;.// Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:Supplement Card before the expiration date. H found return to: Reaistratiori Expiration Office of Consumer Affairs and Business Regulation 140077 09/15(2021 1000 Washington Street - 710 PIONEER VALLEY PHOTOVOLTAICS COOP Boston,MA 02118 MAYA FULFORD i J 311 WELLS ST SUITE B n+../ 1(•1444/s ,'� ���.• A_ GREENFIELD,MA 01301 -'of vali')- ithout signal Undersecretary / / , 0 DATE(MM/DD/YYYY) ACCORD CERTIFICATE OF LIABILITY INSURANCE 12/22/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Kathy Parker NAME: Webber&Grinnell PHONE (413)586-0111 FAX (413)586-6481 (A/C,No,Eat): (A/C,No): 8 North King Street E-MAIL kparker@webberandgrinnell.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC C Northampton MA 01060 INSURER A: Ohio Casualty/Liberty 24074 INSURED INSURER B: Ohio Security/Liberty 24082 Pioneer Valley PhotoVoltaics Cooperative,Inc. INSURER C: Continental Indemnity/AUW Attn:Kim Pinkham INSURER D: 311 Wells Street,Suite B INSURER E: Greenfield MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER: CL20122214681 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN.THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MMIDD/YYYY) (MM/DDIYYYY)- LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE OCCUR DAMAGE TO RENTED 300,000 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 15,000 — A — BKS57072282 01/01/2021 01/01/2022 PERSONAL&ADVINJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY ❑PRO00 JECT LOC PRODUCTS-COMP/OPAGG $ 2,00" OTHER. $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) ANY AUTO BODILY INJURY(Per person) $ B OWNED v SCHEDULED BAS57072282 01/01/2021 01/01/2022 BODILY INJURY(Per accident) $ AUTOS ONLY /—•• AUTOS X AUHIREDTOS ONLY X NON-OOWNESONLD PROPERTY DAMAGE (Per accident) $ ^_ AUTY _ Underinsured motorist $ 300,000 UMBRELLA LIAB "�""""'�CURR'"CE 5,000,000 X _ OCCUR EACH OCCURRENCE $ A EXCESS LIAR CLAIMS-MADE US057072282 01/01/2021 01/01/2022 AGGREGATE $ 5,000,000 DED >4 RETENTION$ 10,000 $ WORKERS COMPENSATION PER I OTH- AND EMPLOYERS'LIABILITY YIN STATUTE ER C ANY PROPRIETOR/PARTNER/EXECUTIVE N NIA 375928710101 01/01/2021 01/01/2022 E.L.EACH ACCIDENT $ 1.000'000 OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1.000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Business Pers Property $1,820,700 Commercial Property A BKS57072282 01/01/2021 01/01/2022 Installation $25,000 Transportation $75,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Worker's compensation includes MA and NY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Proof of Insurance ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts 1. Department of Industrial Accidents 1 Congress Street, Suite 100 __`_`_ Boston, MA 02114-2017 ,vww.mass.gov/dia N. Workers' Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address: 311 Wells Street, SuiteB City/State/Zip:Greenfield MA 01301 Phone#:413-772-8788 Are you an employer?Check the appropriate box: Type of project(required): 1.0 I am a employer with 48 employees(full and/or part-time).* 7. ❑New construction 20 I am a sole proprietor or partnership and have no employees working for me in 8. ❑ Remodeling any capacity.[No workers'comp.insurance required.] IC I am a homeowner doing all work myself.[No workers'comp.insurance required.]i 9. El Demolition 4.0 I am a homeowner and will be hiring contractors to conduct all work on my property. 1 will 10 El Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.❑Roof repairs These sub-contractors have employees and have workers'comp.insurance.: 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.�✓ Other Solar PV 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. 'Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Continental Indemnity/AUW Policy#or Self-ins.Lic.#:37-592871-01-01 Expiration Date:01/01/2022 Job Site Address: 4 Rust Ave City/State/Zip:Northampton MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Ak I do hereby ce t r t,a ai s and penalties of perjury that the information provided above is true and correct. Signatu- . %, =� � - - Date: 4/15/2021 Phone#:413-772-87 8 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone#: KARATSOREOS RESIDENCE N 4 RUST AVE ® SITE MAP III ;���ry-�;;:a� z S CO namasee NORTHAMPTON, MA 01060 �'=y '` �' `�� 0 op SOLAR - � - 1.0100..01.416.31.0.1410 a PHONE:(509) 288-9854 "e"� v „ .. ; R0 �� w or \ wE MAIL:IKARATSOREOS@ME.COM A"' '" • q`Xale 'r '. •- o ',I! /` Cr a2 ' u t%Ave _ _ cl • "Ithmpo •a:060 Q wf6.57KWDC • 32 nw ROOF MOUNTED PHOTOVOLTAIC SYSTEM `, "r"'_ J '' -;:cif-,` fir. ,. " %'y, 0 c H PHOTOVOLTAIC SYSTEM DETAILS ^�' s T 1 a CC CC IL • MODULES = REC REC365AA BLK 365W (I8 PCS) �.' • ',�L H"" 1 ''• '4,4 0cn • INVERTER = SOLAREDGE SE6000H-US (I PCS) �, • •iv` - • Q • RACKING SYSTEM = IRONRIDGE XRI00 W/ QUICKFOOT ' t,✓• t : • , �� ��f/ Q •DATA ACQUISITION =SOLAREDGE CONSUMPTION MONITORING Ct Q O Z AUTHORITY HAVING JURISDICTION N • BUILDING AUTHORITY = KEVIN ROSS (413) 587-1239 ® VICINITY M A P • ELECTRICAL AUTHORITY = ROGER MALO (413)587-1244 • CODE REFERENCE = 2020 NEC aaveero oot Y a commuedr Gardens • ELECTRICAL UTILITY COMPANY = NGRID Qw Light of Coy Bindery $ DESIGN CRITERIA . 0 "'•"�` sz •DESIGN WIND LOAD = 117 MPH ' © K.9 Mevp AND •DESIGN ROOF SNOW LOAD = 40 PSF � � ;�'$ "-' y •EXPOSURE CATEGORY = C Lti.it m.eeV a. >o 0 •HIGH TEMP(ASHRAE 2% HIGH) = 32°C ago = s.> ti •LOW TEMP(ASHRAE EXTREME LOW) _ -20°C KrnQ ��a •ROOF TYPE =ASPHALT SHINGLE •�I�eU+e Nodh•dgo MA 01060 „z, i ago i 'e, SHEET INDEX PV-G.0 COVER PAGE PV-A.I ARRAY LAYOUT PV-E.I LINE DIAGRAM C w . CD • PV-E.2 ELECTRICAL CALCS w e PV-P.I PLACARDS > Q o T 9 _ z 0_ ROOF CONSTRUCTION ',=, .0. • ROOF TYPE = ASPHALT SHINGLE • PV ARRAY = 335 SQUARE FEET DESIGN INPUTS- SATELLITE IMAGERY &FIELD MEASUREMENTS • TYPICAL ATTCHMENT SPAN = 46" • MAX ATTACHMENT SPAN = 76" CO namasGe • MAX CANTILEVER = 30.4" go SOLAR • ATTACHMENTS SHALL BE STAGGERED SO THE LOAD IS DISTRIBUTED EVENLY TO RAFTERS UNDERNEATH THE ARRAY MODULE CLAMP ZONES MAIN SERVICE PANEL - INTERIOR w o (BASEMENT) MODULE MODEL: REC365AA BLK U o Z O MODULE DIMENSIONS: 67.75" X 40.00" w CLAMP BETWEEN: 8.2" - 23.8" ON THE LONG SIDE •© UTILTY METER - EXTERIOR v) w Q 4" -9.8" ON THE SHORT SIDE LU Q E Dv SMART METER - EXTERIOR z -ri 0- PV AC DISCONNECT - EXTERIOR o j z cL IX Ct INVERTER - INTERIOR o s Q (BASEMENT) Q C o a Z i I I RAFTERS, 16" O.C. ' RAIL d ATTACHMENTS Sr' . III/�• 3� 1) axLI1 is I =p,r.=e_ %gP I I l l l l I ARRAY INFORMATION STRING CONFIGURATION Q _, Q 6' STRING SIZE DOES NOT VARY 0 MOD QTY ��° STRINGS QTY Ct Q Z TISTRING I 9 Q CL AZIMUTH 220° STRING 2 9 New England Construction Engineering, PLC 436 Campbell Street (NECE) Structural Construction Solutions White River Junction, VT 05001 Jonathan Rugg, P.E. 603-903-9798 j.rugg@NewEnglandConstructionEngineering.com April 7, 2021 Ms. Madeleine Geschwind Pioneer Valley PhotoVoltaics Cooperative, Inc. 311 Wells Street, Suite B Greenfield, MA 01301 Re: Karatsoreos Residence, MA NECE Project No. 20-01 T-27 Dear Ms. Geschwind, At your request New England Construction Engineering, PLC (NECE) has reviewed the information that Pioneer Valley PhotoVoltaics Cooperative, Inc. (PV Squared) provided on the Karatsoreos residence, at 4 Rust Avenue, in Northampton, MA. The purpose of this review was to provide an opinion regarding the structure's capacity to support a proposed rooftop mounted photovoltaic (PV) array.The information that you provided is attached to this letter for reference. You are proposing to mount PV panels on one side of the house roof. The house is a recently constructed, two-story,wood framed home with unfinished attic. You have provided selected architectural plans by Laura's Architectural Drafting and Design, dated May of 2019. The main house measures approximately 30'x30'. The house has a gable roof with an 8/12 pitch. The roof is supported by 2x10 rafters at 16" O.C. These rafters span approximately 15' on the horizontal. Second-floor ceiling joists resist the outward end reaction of the rafters on the walls. The roof has a structural wood panel (OSB) deck, and asphalt shingles. The photographs that you provided suggest that the house is well maintained, and the roof is performing well. NECE's review and analysis included controlling gravity load combinations (snow and dead load). Development of sloped roof snow loads (Ps) indicated that the increase in dead load from the PV array, is more than offset by the reduction of sloped roof snow load, owing to the smooth surface of the PV panels. This is the case despite the higher thermal coefficient (Ct) due to the air space (thermal break) under the PV panels. Conclusion: Based on the information that you provided and my analysis, I conclude that the house roof will support your proposed PV array. I base this opinion on the following. The PV panels will be New England Construction Engineering, PLC PV Squared— Karatsoreos Residence Jonathan Rugg, P.E. Northampton, MA Page 2 of 2 installed parallel to the roof, eliminating additional wind load.The ground snow load (Pg)for Northampton is 40psf. The minimum flat roof snow load (Pf) is also 35psf. The information that you provided on similar projects indicates that the proposed panels weigh approximately 2.3psf. In summary, in my opinion, the roof will support your proposed PV array. Thank you for the opportunity to assist with this project. If I can be of further assistance, please contact Jonathan Rugg at NECE. ‘kof I4AS 4� s�� o* yGSincerely, JONATHAN A o rm RUGG �/' ' No. 51982 '� . ;����j Ld..L� �: C C Jonathan Rugg, P.E. � G New England Construction Engineering, PLC. t,,,w„ , - le)4 /2/21 Attachments: -Building& Proposed Array Information l' t• 4 0, ,,.. lit • , i ....._ ,...-- • . IST TRUSTED ... • .. REc .. ........ 0*.J.‘,...,,,„,. , . . . ov \411 .. . . .. ; ;•!...,,s,, . 1 , , ', ': ,,. 0,,., .: • ,, • ' ,,,1 , .•,,,,;.,,,,,I. •:',,— ., .,4„,'21.,' • 1.!., - , , ' • ., ,,,. ,., 3, i, _,, . •, ,, • • ,,, •,,. • .., ,,,, :7,14i. ;.• ,',.,!;„i I i A '•''' • - I il '. , 1 ;I i I , •:.le p. ' IT.:.•1: :!..Al• ; '.1',.:' ;.''..i,A.; . ; 11,,!. ..:•.1';:: ::1::, ;,;;;:r i.:: , :414:11j: 1 1 if ' . -... .• .. . •. ' ! „. • .; . ,. - . .. , ',1•!..., . ir,' .1.! .,, -, '4!j,i I, ....t ,il!j,,i1 # n ';. . ' '' . . , ,‘ :'i''' '' .i ir:'.,'.1., ''.1 11 ' '': ; 11..: ' '''. 1 ' .: •;:',. :1 1 i . .. - '... ' 4t.- I• ....!1 1, '' .t • i+'I.'. ,4 ; I ,•,•‘....; 1r, -• r',',1i1.• 1itl'. ''.11 :: ' •'''' ' '' I ; ' 11 'I'.!! •• . ' ' • . . " it, : . .*' ,' : 1•' • .':', ',,i 'J ' 1 , i'.;;,• ;; :, 1 :...r. ;. ' . ; ; 1.F. ; - . ;.; '• : ; ;'; ; t . . ... ... ;;; . i ', ; .. ; ; • ; - 1 ' ; ; ; r.• . ':;i' ;, .., . . . ti,..,. i . _ • 17.. kt, REE ALPHOC .... L . BLACK SERIES .. . ., .. . .. .... . .. . . ... , . , . .. ,----'ir--2.0DUci. inter r,---- --,,,,,,,,N,\N.\ EXPERIENCE 375 _ 25 YEAR c,c,), i i\LJ i Fcl_ 13 award WP 0 POWERWINNER ELIGIBLE FOR PERFORMANCE CERTIFICATIONS IEC 61215:2016,IEC 61730:2016,UL1703,UL61730 1721±2.5(67.75±0.11 -_... •�28[1.11 ,� - 1102[31.5] _.�,� 455[17.9] IEC62804 PID IEC61701 Salt Mist + • IEC 62716 Ammonia Resistance �~ 1000[39) UL1703 Fire Type Class 2 • IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone(35mm) • A54040.2 NCC 2016 Cyclic Wind Load +d 15014001:2004,1509001:2015,0HSAS18001:2007,IEC62941 g sA°s C E 111 a u 2 n 11t0.2 WARRANTY 1[0.43*0.81 • Standard RECProTrust J Installed by an REC Certified No Yes Yes R. 20st0 Solar Professional 10.78 t0A8] 1200 N71 _... ��� a System Size All '25 kW 25 500 kW 1.. - Product Warranty(yrs) 20 25 ......._25 k Power Warranty(yrs) 25 25 25 45[15] 2231011 621±3[245*0.12] r Labor Warranty(yrs) 0 25 10 Power in Year 1 •'98% 98% 98% Measurements in mm[in] - ♦GENERAL DATA Annual Degradation 025% 0,25% 025% 120 half-cut cells with REC Power in Year 25 92% 92% 92% StaubliMC4PV KBT4/KST4,12AWG(4mm) See warranty documentsfor details.Conditions apply. Cell type: heterojunction cell technology Connectors: in accordance with lEC 62852 • 6 strings of 20 cells in series IP68 only whenconnected 'MAXIMUM RATINGS 0.13 in(3.2 mm)solar glass with 12AWG(4mm2)PVwire,39+47in(1+1.2m)in Glass: anti-reflection surf ace treatment Cable: accordancewith EN 50618 Operational temperature: 40...+85°C Highly resistant 67.8x40x1.2in(1721x1016x30mm) Maximum system voltage: 1000V Backsheet: Dimensions: a Design (+):snow 4666Pa 97.51bs s ft polymeric construction(black) 18.8sgft(1.75m2) 8 ( lbs/sq )' Maximum test load(+): 7000 Pa(146 lbs/sq ft)* Frame: Anodized aluminum(black) Weight: 43lbs(195kg) Design load(-):wind 2666 Pa(55.6 lbs/sq ft)' Junction box: 3-part,3bypassdiodes,IP67rated Origin: MadeinSingapore Maximum test load(-): 4000Pa(83.5lbs/sgft)* ?; in accordance with IEC 62790 Max series fuse rating: 25A I ELECTRICAL DATA Product Code':RECxxxAABlack Max reverse current: 25A t Power Output-PM (Wp) 355 360 365 370 375 Calculated using asafety factor ofl.S m Watt Class Sorting-(W) -0/+5 -0/+5 -0/+5 -0/+5 -0/+5 See installation manual for mounting instructions -6 Nominal Power Voltage-V (V) 36.4 36.7 37.1 37.4 37.8 f TEMPERATURE RATINGS o ;, H Nominal Power Current-IMw(A) 9.77 9.82 9.85 9.9 9,94 Nominal Module Operating Temperature: 44°C(i2'C) 6 VI Open Circuit Voltage-Voc(V) 43.6 43.9 44.0 44.1 44.2 Temperature coefficient ofPmx: -0.26%/'C o Temperature -0.24%/'C Short Circuit Current-Ix(A) 10.47 10.49 10.52 10.55 10.58 Tem P a _ Power Density(W/sgft) 18.88 19.15 19.41 19.68 19.94 Temperature coefficient ofI,r: 0.04%/°C ifl Panel Efficiency(%) 20.3 20.6 20.9 21.2 21.4 The temperature coefficients stated are linear values Power Output P W ♦LOW LIGHT BEHAVIOUR P tux( p) 271 274 278 282 286 N Typical low irradiance performance of module at STC: Nominal Power Voltage-Vmpp(V) 34.3 34.6 35.0 35.2 35.6 6 Z IN o Nominal Power Current-1Mw(A) 7.89 7.93 7.96 8.00 8.03 w cc Open Circuit Voltage-Vo,(V) 41.1 41.4 41.5 41.6 41.6KJ a c Short Circuit Current-I„(A) 8.46 8.47 8.50 8.52 8.55 i Values at standard test conditions WC:air mass AM1 5,in-adiance10.75W/sq ft 0000 W/ml.temperature 77'F(25*C),based on a production 9 spread witha tolerance ofP V &Ixi3%withinonewatt class.Nominal module operating temperature(NMOT:air mass AMl.S.irradiance „ 800W/rrP,temperature 68 20�C),windspeed33ft/sf m/s).'Wherexxx indicates the nominal powerclass(P,,)atSTCabove. Irradiance(W/m9 Ir. e ,+ REC Group is an international pioneering solar energy company dedicated to empowering m, ( ' a 1� .Y consumers with clean,affordable solar power in order to facilitate global energy transitions. eo, RE y 3 i• k `• ' * '1' Committed to quality and innovation,REC offers photovoltaic modules with leading high quality, f `£ i 1+ Y t ` r , t t backed by an exceptional low warranty claims rate of less than 100ppm.Founded in Norway inl996, wwwrecg[. 1 ` 'F ' 1 % ',t, • 1 Tt's REC employs 2,000 people and has an annual solar panel capacity of 1.8 GW.With over 10 GIN �. •0 ,`� • + h. rA installed worldwide,REC is empowering more than 16 million people with clean solar energy.REC w , Group is a Bluestar Elkem company with headquarters in Norway,operational headquarters in (a ® 1 t. j�` ',S ; 1 Singapore,and regional bases in North America,Europe,and Asia-Pacific. " y ° "2 ,s 4t Cut Sheet IRONRIDGE XR100 Rail See Descri tion / t enc7tt 4 Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in2 .66 Section Modulus (X-axis) 0.297 in3 .46 Moment of Inertia (X-axis) 0.390 in" Moment of Inertia (Y-axis) 0.085 in" Torsional Constant 0.214 in3 Polar Moment of Inertia 0.126 in" 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) i .58 1 1 T I Clear Part Black Part Description/Length Material Weight Number Number . XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) 6000 Series 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 11.60lbs. v1.1 Cut Sheet IRONRIDGE XR100 Bonded Splice I .0...".""°"co XR-100 RAIL 12.0 L1,1011019 I XR-100-SPLC-BD KIT, XR100 BONDED SPLICE 1) Splice, XR100, Mill 12" long 2) Screw, Self Drilling 1.24 .63 1.93 .31 FOP 0.42 .15- i .93 f #12-14 TYPE "B"THREAD Property Value Property Value Material 6000 Series Aluminum Material 300 Series Stainless Steel Finish Mill Finish Clear vl.0 ti) Z QuikFoot PRODUCT GUIDE O Exploded Product View/B.O.M. - 1 Installation Instructions - 2 Cut Sheets - 3 Specifications -4 J Cl• 3— uJ lam uLLJ J pAQ --- ;Oa EcoFasten Solar` QuikFoot— Product Guide Exploded Product View, Bill of Materials Materials Needed for Assembly I l O _ Item No. Description of Material/Part Quantity vii1 QuikFoot Base Plate 1 i • ' 2 Fastener(Length to be determined) 2 tit3 QuikFoot Flashing 1 © 4 EPDM Washer 1 "i 1111.111114 O5 L-102-3"Bracket*(other options available) 1 : ' Cr) O 6 5/16"EPDM Bonded 18.8 SS Washer 1 7 3/8"Stainless Steel Hex Nut 1 CI) immi Required Tools I w o 410 0 V0 LIMIllilimkiiiiimitilatio- ,.. r 1 4111A • C4 D �a 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 1.1 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 82 8,245,454 B2 8,272,174 B2 8,225,557 B2 QuikFoot— Product Guide Cut Sheets: QF-AL-Base 2X 0 .33in [8.38mm] Igi Cid JD o � Lo � u u WiMi (114 0 (Ni ,i cf5 (Ni rTl tit O _p_i 1 .50in La_ Co) [38.10mm] IIIrT1 3/8"-16 Stud t1 ooa N QF-M : 1 .5" QF-L : 1 .75" t ___..t I, M. II. IIMEN. UT 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 3.1 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8.245,454 B2 8,272,174 82 8,225.557 B2 QuikFoot- Product Guide • Cut Sheets: QFL-81 2 R.38in [9.53mm] .032in [0.81mm] tit -N A CI:01 Cf) .. .. Z 41 (n 12.00in rTI [304.80m m] II rT1 L Oo 11 3.00in aA [76.20 m m] =J v Sam koectionr isaOQ L .50in _ �' 8.00in _ [ 12.70mm 1 �. [203.20mm] 11111 877-859-3947 EcoFasten Solar®All content protected under copyright.Alf rights reserved.10/09/14 3.2 EcoFasten Solar products are protected by the following U.S.Patents:8.151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 r G QuikFoot- Product Guide Cut Sheets: Bracket Options- SCL-101-3 , i 3/8" !- -1 A CI , 46 SERRATIONS li l O Cf) in r U 0 = so VJ t - R1/16r PlIZ 1/4 - co 1/16" ---] / a R.005 R.010 pz4 2X R.01 © �1 60.00° Q n+ 08 \ - L__ L6 0 3/8 1/8" 0 \/ 0 7/8" X82° EAISE3i 877-859-3947 EcoFasten Solar•All content protected under copyright.All rights reserved.10/09/14 3.7 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 QuikFoot- Product Guide Specifications PART 1 -GENERAL • 1.1 SUMMARY 1.3 SUBMITTAL A WORK INCLUDES A Submit manufacturer's written specifications. B. Base plate is 6000 series aluminum with one 1. QuikFoot base plate attachment bracket that B. Submit standard product cut sheets. PEM Type Press-In Stud 18.8 SS. attaches directly to the roof deck. C. Submit installation instructions. C. Fasteners to be compatible with chosen roof 2. Provide appropriate bracket and fasteners D. Submit product specific load test data,showing application and meet specified pull out values for the roof system. ultimate and allowable load values specific to as shown in load test data. B. RELATED SECTIONS the roof deck specified for the project. D. Counter flashing is.032 gauge aluminum em- tit 1.Section 07600:Flashing and Sheet Metal bossed to accept shape of stainless steel base 2.Section 07500:Roofing 1.4 QUALITY ASSURANCE plate , 3.Division 1:Administrative and Procedural O Installer to be experienced in the installation of Requirements specified roofing material for no less than 5 years in 2.3 FINISH 4,' Cip 4.Division7:Thermal and Moisture Protection the area of the project. z i 1.2 SYSTEM DESCRIPTION A. Bracket is mill finish aluminum 4- 1.5 DELIVERY/STORAGE/HANDLING B. Base flashing-Black-kynar painted A. COMPONENTS: Inspect material upon delivery.Notify manufacturer 1. QuikFoot system consists of aluminum within 24 hours of any missing or defective items. PART 3- EXECUTION • bracket and base plate with(1)stainless steel Keep material dry,covered,and off the ground until CD stud,(1)stainless steel nut,(1)EPDM washer installed. and(1)bonded stainless steel and EPDM 3.1 EXAMINATION �/� washer.Cli A. Substrate:Inspect structure on which brackets 2. Fasteners PART 2 -PRODUCTS are to be installed and verify that it will with- A.To be of metal compatible with QuikFoot stand bracket. 2.1 MANUFACTURER any additional loading that maybe incurred. 1111111100.4 B.Fasteners should be selected for compat- ibility with the roof deck. 289 Harrel Street,Morrisville,VT 05661 B. Notify General Contractor of any deficiencies 11111110 C.Fastener strength should exceed or be (877)859 3947 before installing EcoFasten Solar brackets. equal to that of the allowable load of the www.ecofastensolar.com C. Verify that roofing material has been installed system.See test data at 2.2 MATERIALS correctly prior to installing solar attachment www.ecofastensolar.com brackets. " CI il ITI 4A 3. Sealant(if required by roof manufacturer): A. Attachment Bracket to be roof manufacturer approved. 6000 Series Aluminum(choose one) PP 3.2 INSTALLATION '; Q 4. Aluminum counter-flashing 1.CP-SQ-Slotted A. Comply with architectural drawings and project A 5. Aluminum attachment bracket 2.F-111-A engineer's recommendations for location of Q D 3.P-3-CSK system.Comply with Manufacturer's written in- k' 4 B. DESIGN REQUIREMENTS: 4.SCL-101-3 stallation instructions for installation and layout. 1. Bracket spacing to be recommended by 5. L-102-3" project engineer. 6.L-102-6" 2. Install a minimum of two fasteners per 7.Z-101 base plate. 8.Comp Slide .,• ` 3. It is important to design new structures or 8.Custom assess existing structures to make sure that • they can withstand retained loads. • 877-859-3947 EcoFasten Solar®All content protected under copyright.All rights reserved.10/09/14 4.1 EcoFasten Solar products are protected by the following U.S.Patents:8,151,522 B2 8,153,700 B2 8,181,398 B2 8,166,713 B2 8,146,299 B2 8,209,914 B2 8,245,454 B2 8,272,174 B2 8,225,557 B2 3/8" - • A 46 SERRATIONS co No R1/16" 1 7/8" 1/4" oD — 3/4" 1/16" � R.005 R.010 /� rr 2X R.OI ® 60.00° 0 3/81(01 1/8" Y 0 7/8" X 82° DETAIL A X = +/- •1 SCALE 3:1 .XX = +/- .01 .XXX= +/- .005 289 Harrel Street pip Morrisville, VT 05661 SCL-101 -3 iEIriEcoFasten Solaro Toll Free Phone 1.8 . . 9 Toll Free Fax 1.888.766.9994 MATERIAL: 6000 SERIES ALUMINUM V web www.ecofastensolar.com _ e-mail info@ecofastensolar.com SCALE: 1:1 1/6/2012 SHEET 1 OF 1 Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 INSTALLATION CREW OPERATING POLICY This policy applies to all PV Squared employees in Massachusetts, but is particularly directed at those involved in the installation of solar electric and other renewable energy systems (licensed electrician, learner/apprentice electrician, licensed constructor supervisor, supervised carpenter and laborer). When engaged in this work as an employee of PV Squared on a PV Squared project site, activities of PV Squared employees are covered under the General Liability Insurance maintained by the Cooperative. It is the intent of this policy to provide clarity to installation situations where the applicable codes and regulations are unclear, ambiguous, or silent. It is possible that a municipal building or electrical inspector could interpret the codes and regulations in a manner that differs from what appears here. But this policy sets out, in writing, how the cooperative interprets legal work requirements and unclear details. It is an internal consensus working model, intended to be revised and improved from time to time. As a general matter, a city's or town's Building Commissioner is charged with enforcing the State Building Code, Plumbing and Gas Code, Electrical Code and Architectural Access Code. The commissioner addresses concerns about the safety, accessibility and security of construction of homes and businesses. The commissioner also enforces zoning bylaws. In accordance with Massachusetts General Law, employees of the cooperative who perform electrical tasks and activities must hold a Massachusetts journeymen's electrician license or be under the direct supervision of such licensed personnel. These tasks and activities include installing electrical wiring, conduits, apparatus, devices, fixtures or other appliances for carrying or using the electricity associated with Renewable Energy Generators (electrically active solar photovoltaic modules, wind turbine-generators, hydroelectric generators, etc.). In no circumstances shall the Massachusetts licensed journeymen have more than one learner or apprentice working with him/her or under his/her supervision. Mounting structures come in a variety of configurations and have differing functional and physical characteristics. A structural component or assembly becomes associated with electrical work as the Renewable Energy Generator is electrically bonded to the mounting structure. Unless otherwise noted in M.G.L. c.143 §S3 through §S60 inclusive, all structural work defined as follows shall not be required to be performed by a Massachusetts licensed journeymen electrician: • Structural improvements • Elements of a Renewable Energy Generator's support structure that fall under a building permit (e.g., assembly of top-of-pole mounting structure on steel pole with concrete foundation prior to execution of any required electrical bonding of the support structure and associated renewable energy generator (solar electric module) to the support structure Policy # 9 Installation Crew Operating Policy Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 • Roof-top mounting support structures including but not limited to posts, stand-offs, flashings, feet, and mounting rails • Operation of heavy equipment involved in moving, hoisting, digging and other tasks • Earth work, excavation and concrete work • Manual labor involved in moving loading and unloading of equipment • Moving, hoisting, and attaching an electrically bonded panel assembly (defined as one or more assembled and electrically bonded solar electric modules) to an existing structural support designed to host the panel assembly. Note however that construction of a panel assembly is an electrical task due to the required electrical bonding activities. Repair and Servicing of Installed Equipment Repair or replacement of an electrically bonded and/or energized renewable energy generator (e.g., installed solar electric panel) will be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician. Replacement of an installed inverter must be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician, if the work requires removal of AC and/or DC conduit and associated wiring that originates outside of the installed inverter (e.g., removal of external AC conduit and wiring between the inverter and point of interconnection with the on-site electrical service). Note that this activity may require a wiring permit in some local jurisdictions. This requirement also applies to the servicing of an installed inverter that involves replacement or repair of components and wiring internal to the pre-manufacturer inverter (i.e., factory installed components that were originally shipped with the inverter) even though such activity may not require a wiring permit. Replacement of an installed inverter may also be performed by a qualified technician who may or may not be a licensed electrician or properly supervised learner or apprentice working with a licensed electrician if the inverter is of a "plug and play" design. Such a qualified technician can also performed other tasks that include installation and servicing inverter-based performance monitoring systems (e.g., replacing internal communication cards, making "plug and play" ethernet connections, etc.), assuming these activities do not require creation of a new AC power source circuit to operate the communication system(s). Policy # 9 Installation Crew Operating Policy Non Electrical Work at a typical PV Squared installation: • All Material Handling tasks o Module prep and moving o Ladder lift set up o Ladder set up o Trash/recycling removal and sorting • Structural Improvements o All carpentry work • Roof Mount Array o Fall protection anchor setup and removal o Layout and mounting bases o Racking up to but not including"bonding/grounding related activities" o Leveling of racking o Sealing seams/patching roofing/additional flashing • Ground mount array o Site work, earth moving o Trenching/digging o Construction of racking up to but not including "bonding/grounding related activities" • Conduit run o Making holes in structure o Fire blocking, sealing penetrations o Stickers • Power Board o Build wall, hang plywood o Stickers • Interconnection o Stickers • Monitoring o Wifi options o Any"plug and play"devices o Programming of monitoring devices o Computer based activities • Installation completion o Final building inspections o Install pictures-See checklist o Update one line and roof drawings to reflect as built o Completion checklist o Notes for others o COC left onsite • Misc o Truck Organizing o Material List, ordering o Daily check-in o Customer interaction and training activities