Loading...
Stamped_221R-040GILL_PE1 - Rev AAstra v.1.36 April 1, 2021 PIL CAT 1 Subject : Structural Certification for Proposed Residential Solar Installation. Job Number: 221R-040GILL; Rev A Client: sarah gilleman Address: 40 Spring St, Northampton, MA, 01062 Attn: To Whom It May Concern Digitally Signed on: 4/1/2021 A field observation of the existing structure at the address indicated above was performed by a site survey team from Sunrun. Structural evaluation of the loading was based on the site observations and the design criteria listed below. Design Criteria: • MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC), 7-10 ASCE & 2015 NDS • Basic Wind Speed V = 117 mph, Exposure B • Ground Snow Load = 40 psf, Min Flat Roof Snow Load = 35 psf Based on this evaluation, I certify that the alteration to the existing structure by the installation of the PV system meets the requirements of the applicable existing building and/or new building code provisions referenced above. Additionally, I certify that the PV module assembly including all attachments supporting it have been reviewed to be in accordance with the manufacturer's specifications. Results Summary (Hardware Check Includes Uplift Check on Attachments/Fastener, Structure Check Considers Main Structure) AR-01 Orientation Attachment Spacing/Cantilever Configuration Governing DCR Result Landscape 72 / 28 Staggered 41%Pass Portrait 48 / 23 Staggered 45%Pass Roofing Material Pitch Structure Check Comp Shingle 32°Pass AR-02 Orientation Attachment Spacing/Cantilever Configuration Governing DCR Result Landscape 72 / 28 Staggered 41%Pass Portrait 48 / 23 Staggered 45%Pass Roofing Material Pitch Structure Check Comp Shingle 32°Pass 225 Bush St. Suite 1400 San Francisco, CA 94104 | P (949)383-0993