Stamped Plans_Gilleman Sarah_Rev ACOVER SHEET SCOPE OF WORK GENERAL NOTES REV NAME DATE COMMENTS A AC AFCI AZIM COMP DC (E) ESS EXT INT MAG MSP (N) NTS OC PRE-FAB PSF PV RSD TL TYP V W AMPERE ALTERNATING CURRENT ARC FAULT CIRCUIT INTERRUPTER AZIMUTH COMPOSITION DIRECT CURRENT EXISTING ENERGY STORAGE SYSTEM EXTERIOR INTERIOR MAGNETIC MAIN SERVICE PANEL NEW NOT TO SCALE ON CENTER PRE-FABRICATED POUNDS PER SQUARE FOOT PHOTOVOLTAIC RAPID SHUTDOWN DEVICE TRANSFORMERLESS TYPICAL VOLTS WATTS PAGE REV: A 4/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 SARAH GILLEMAN 40 SPRING ST, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 221R-040GILL SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (413) 218-3435 APN #: APN: NHAM-000022B-000057-000001 #180120 (415) 580-6920 ex3 TABLE OF CONTENTS PAGE #DESCRIPTION PV-1.0 COVER SHEET PV-2.0 SITE PLAN PV-3.0 LAYOUT PV-4.0 ELECTRICAL PV-5.0 SIGNAGE PV-1.0 VICINITY MAP • SYSTEM SIZE: 3465W DC, 3800W AC • MODULES: (11) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M • INVERTERS: (1) SOLAREDGE TECHNOLOGIES: SE3800H-USM3 • RACKING: SNAPNRACK RLU; RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 • ENERGY STORAGE SYSTEM: (1) LG CHEM: RESU 10H SEG, 9.8 KWh, 5KW LITHIUM-ION BATTERY (WEIGHT: 214LB EACH). #SSTAMPCS #ESTAMPCS • ALL WORK SHALL COMPLY WITH MA 9th Ed. CMR 780 (2015 IRC/IBC/IEBC), MUNICIPAL CODE, AND ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • SNAPNRACK RACKING SYSTEMS, IN COMBINATION WITH TYPE I, OR TYPE II MODULES, ARE CLASS A FIRE RATED. • RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. • 9.94 AMPS MODULE SHORT CIRCUIT CURRENT. • 15.53 AMPS DERATED SHORT CIRCUIT CURRENT [690.8 (a) & 690.8 (b)]. • PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(B)(2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION • ENERGY STORAGE SYSTEM CONFORMS TO AND IS LISTED UNDER UL 9540. • ENERGY STORAGE SYSTEM LIVE PARTS ARE NOT ACCESSIBLE DURING ROUTINE MAINTENANCE. SYSTEM VOLTAGE IN ACCORDANCE WITH NEC 706.30 AND EXCEPTION 1 NEC 706.30 (A). • ADDITIONAL DISCONNECTING MEANS SHALL BE INSTALLED WHERE ENERGY STORAGE DEVICE INPUT AND OUTPUT TERMINALS ARE MORE THAN 5 FT FROM CONNECTED EQUIPMENT, OR WHERE THE CIRCUITS FROM THESE TERMINALS PASS THROUGH A WALL OR PARTITION PER 706.7(E). • LISTED, COMBINATION TYPE AFCI SHALL BE INSTALLED WHERE BACKED UP CIRCUIT WIRING IS EXTENDED MORE THAN 6FT AND DOES NOT INCLUDE ANY ADDITIONAL OUTLETS OR DEVICES PER NEC 210.12(D). • THE CAPACITY OF THE STANDALONE SYSTEM SUPPLY SHALL BE EQUAL TO OR GREATER THAN THE LOAD POSED BY THE SINGLE LARGEST UTILIZATION EQUIPMENT CONNECTED TO THE SYSTEM PER NEC ARTICLE 710.15(A) • ALL PASS-THROUGH CONDUCTORS MUST COMPLY WITH NEC 312.8 LEGEND AND ABBREVIATIONS SCALE: NTS PVC PIPE VENT SATELLITE DISH T-VENT FIRE SETBACKS METAL PIPE VENT HARDSCAPE PROPERTY LINE INTERIOR EQUIPMENT SHOWN AS DASHED PL MAIN PANEL PV LOAD CENTER SUB-PANEL SUNRUN METER DEDICATED PV METER SERVICE ENTRANCE INVERTER(S) AC DISCONNECT(S) DC DISCONNECT(S) CB IQ COMBINER BOX ENERGY STORAGE SYSTEM BP BACKUP LOADS PANEL SOLAR MODULES SNR A MOUNT SNR B MOUNT ATTIC VENT FLUSH ATTIC VENT CHIMNEY SE MP SP LC SM PM INV AC DC BI BACKUP INTERFACE 1 COMMUNICATION WIRES EXTERNAL RAPID SHUTDOWN SWITCH RSD PL PL PL PL PL PL P L P L P L P L PLPLPLPLPL PL P L P L P L PAGE REV: A 4/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 SARAH GILLEMAN 40 SPRING ST, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 221R-040GILL SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (413) 218-3435 APN #: APN: NHAM-000022B-000057-000001 #180120 (415) 580-6920 ex3 SITE PLAN ARRAY PITCH PV AREA (SQFT) AR-01 32°144.3 AR-02 32°54.1316° TRUE AZIM MAG AZIM 150°136° 330° PV-2.0 #SSTAMPSP #ESTAMPSP BPBI SITE PLAN - SCALE = 1/16" = 1'-0" (N) ARRAY AR-01 MP (N) ARRAY AR-02 (E) GATE (E) DETACHED STRUCTURE (E) DRIVEWAY S PR ING S T PM DC SE AC INV PAGE REV: A 4/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 SARAH GILLEMAN 40 SPRING ST, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 221R-040GILL SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (413) 218-3435 APN #: APN: NHAM-000022B-000057-000001 #180120 (415) 580-6920 ex3 PV-3.0 LAYOUT #SSTAMP ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height Type Max Span OC Spacing Detail Max Landscape OC Spacing Max Landscape Overhang Max Portrait OC Spacing Max Portrait Overhang Configuration AR-01 COMP SHINGLE - RLU 2-Story TRUE CUT 2X4 RAFTERS 8' - 3"24"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 6' - 0"2' - 4"4' - 0"1' - 11"STAGGERED AR-02 COMP SHINGLE - RLU 2-Story TRUE CUT 2X4 RAFTERS 8' - 3"24"RL UNIVERSAL, SPEEDSEAL TRACK ON COMP, SEE DETAIL SNR-DC-00436 6' - 0"2' - 4"4' - 0"1' - 11"STAGGERED DESIGN CRITERIA MAX DISTRIBUTED LOAD: 3 PSF SNOW LOAD: 40 PSF WIND SPEED: 117 MPH 3-SEC GUST. STRUCTURAL NOTES: ·INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. ·IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED WITHIN THE 12" BOUNDARY REGION ONLY AS FOLLOWS: ··ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50% ··ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS S.S. LAG SCREWS: 5/16"X4.5": 2.5" MIN EMBEDMENT D1 - AR-01 - SCALE: 1/4" = 1'-0" PITCH: 32° AZIM: 136° D2 - AR-02 - SCALE: 1/4" = 1'-0" PITCH: 32° AZIM: 316° 2'-3"22'-3"3'-2" 1'-3" 6'-7" 2'-8" 4'-2"16'-8"6'-7" 2'-1" 3'-3" 5'-2" 6'TYP 6'TYP JUNCTION BOX MIN RATED NEMA3R SQUARE D HU361RB 3R, 30A, 600VDC (N) HEAVY DUTY SAFETY SWITCH +- LG CHEM RESU 10H, 9.8 KWh, 5KW (1) ENERGY STORAGE SYSTEM 520V MAX VOLTAGE, 14.3A MAX CURRENT NEMA 3R 3 1 3 2 4 PV MODULES LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M (11) MODULES OPTIMIZERS WIRED IN: (1) SERIES OF (11) OPTIMIZERS SOLAREDGE POWER OPTIMIZERS P370 LOAD RATED DC DISCONNECT, AFCI, REVENUE GRADE METER, RAPID SHUTDOWN AND ENERGY STORAGE SYSTEM INPUTS SOLAREDGE TECHNOLOGIES: SE3800H-USM3 3800 WATT INVERTER BATTERY SOLAR 2 3 5 M 240V METER SOCKET 100A CONTINUOUS (N) MA SMART UTILITY REVENUE METER UTILITY SIDE OF CIRCUIT CONNECTS TO TOP LUGS - (LINE AT TOP LOAD AT BOTTOM) (N) 125A BACKUP LOADS PANELFACILITY LOADS (N) 50A FEEDER BREAKER (N) CURRENT TRANSFORMERS 1 (1) 40A BREAKER (N) SOLAREDGE BACKUP INTERFACE BI-NUSGN-01 M 1 200A MICROGRID INTERCON. DEVICE CTRL 25 (N) LOCKABLE BLADE TYPE AC DISCONNECT SQUARE D DU222RB 3R, 60A,2P 120/240VAC 44 3 FACILITY GROUND (N) 50 FEEDER BREAKER AT OPPOSITE END OF BUSBAR EXISTING 100A MAIN BREAKER (END FED) EXISTING 125A MAIN PANEL FACILITY LOADS M METER #: NATIONAL GRID 91836129 120/240 VAC SINGLE PHASE SERVICE UTILITY GRID NOTE: TOTAL PV BACKFEED = 20A USED FOR INTERCONNECTION CALCULATIONS NEW 100A SERVICE DISCONNECT CONDUIT SCHEDULE #CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 3 3/4" EMT OR EQUIV.(2) 10 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 4 3/4" EMT OR EQUIV.(2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 5 1" EMT OR EQUIV.(2) 4 AWG THHN/THWN-2 (1) 4 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 PAGE REV: A 4/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 SARAH GILLEMAN 40 SPRING ST, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 221R-040GILL SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (413) 218-3435 APN #: APN: NHAM-000022B-000057-000001 #180120 (415) 580-6920 ex3 PV-4.0 ELECTRICAL #ESTAMP SYSTEM CHARACTERISTICS - INVERTER 1 SYSTEM SIZE: SYSTEM OPEN CIRCUIT VOLTAGE: SYSTEM OPERATING VOLTAGE: MAX ALLOWABLE DC VOLTAGE: SYSTEM OPERATING CURRENT: SYSTEM SHORT CIRCUIT CURRENT: 3465 W 11 V 400 V 500 V 9.12 A 15 A P370 OPTIMIZER CHARACTERISTICS: MIN INPUT VOLTAGE: 8 VDC MAX INPUT VOLTAGE: 60 VDC MAX INPUT ISC: 11 ADC MAX OUTPUT CURRENT: 15 ADC MODULE CHARACTERISTICS LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR6-60HPB-315M: OPEN CIRCUIT VOLTAGE: MAX POWER VOLTAGE: SHORT CIRCUIT CURRENT: 315 W 40.6 V 33.7 V 9.94 A PAGE REV: A 4/1/2021 734 FOREST STREET #400, MARLBOROUGH, MA 01752 PHONE 888.657.6527 FAX 805.528.9701 SARAH GILLEMAN 40 SPRING ST, NORTHAMPTON, MA, 01062 PROJECT NUMBER: 221R-040GILL SHEET DESIGNER: BRIAN CALDERON CUSTOMER RESIDENCE: TEL. (413) 218-3435 APN #: APN: NHAM-000022B-000057-000001 #180120 (415) 580-6920 ex3 SIGNAGE PV-5.0 #ESTAMP CAUTION: 40 SPRING ST, NORTHAMPTON, MA, 01062 MULTIPLE SOURCES OF POWER PER CODE(S): NEC 2020 and NEC 2017: 705.10 + 710.10 SERVICE ENTRANCE PV PRODUCTION METER(EXT) AC DISCONNECT(EXT) INVERTER(EXT) DC DISCONNECT(INT) ENERGY STORAGE(INT) MAIN PANEL PV BREAKER DISCONNECT(INT) SOLAR PANELS ON ROOF MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 15.83 AMPS 240 VAC LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2020: 690.54, NEC 2017: 690.54, NEC 2014: 690.54, NEC 2011: 690.54 PV SYSTEM DISCONNECT WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC 2020: 705.12(B)(3)(2), NEC 2017: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(3), NEC 2014: 705.12(B)(3), NEC 2011: 705.12(D)(7) NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2020: 690.56(C), NEC 2017: 690.56(C)(1)(a) 4" 3" ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC 2020: 690.13(B), NEC 2017: 690.13(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2020: 690.56(c)(2), NEC 2017: 690.56(C)(3), NEC 2014: 690.12, NEC 690.56, IFC 2012: 605.11.1, IFC 2018: 1204.5.3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM INVERTER 1 PHOTOVOLTAIC DC DISCONNECT MAXIMUM SYSTEM VOLTAGE:VDC480 LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): NEC 2020: 690.53, NEC 2017: 690.53, NEC 2014: 690.53, NEC 2011: 690.53 WARNING: PHOTOVOLTAIC POWER SOURCE WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): NEC 2020: 690.31(D)(2), NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 CAUTION: MULTIPLE POWER SOURCES PER CODE(S): NEC 2020 690.56(B), NEC 2020 705.10 PHOTOVOLTAIC DC DISCONNECT LABEL LOCATION: DC DISCONNECT (PER CODE: IFC.60.11.3 IFC 605.11.1.4 NEC 690.15, NEC 690.13(B) & NEC 690.14C.2.)