24D-344 (3) 21 STODDARD ST BP-2021-1115 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:24D-344 CITY OF NORTHAMPTON Lot: - PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2021-1115 Project# JS-2021-001879 Est.Cost: $26812.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: NORTHEAST SOLAR DESIGN ASSOCIATES LLC 106113 Lot Size(sq.ft.): Owner: PELLETIER MARSHA Zoning: Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC AT: 21 STODDARD ST Applicant Address: Phone: Insurance: 136 ELM ST (413) 247-6045 () Liability HATFI ELDMA01038 ISSUED ON:4/2/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 24 PANEL 8.64 KW SOLAR SYSTEM ON ROOF POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. 1 yJ . Certificate of Occupancy Signatur : FeeType: Date Paid: Amount: Building 4/2/2021 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner CI i b f..,�' _ Department use y City of Nv m n Sta or Perm: Building Q rtmAPR nt _ CurtCuvDrive•,e},Perrril 212 Main Str c 2021 se,sr,Sept: 4;vailabiii;y Room 00 w'awr� A'vaiI bih r Northampton, MA Demo aun_Din�c tntsr�=c ,' >uS�ets�el 61 Stn.i,:L'a Plans phone 413-587.1240 Fay-4 .MAOiat>o_tJSitePlans Other Spec ty APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 11 Prosody AdcMau: TMs section to be completed by oftcs 21 Stoddard St Map ...2`IP Lot .3 L 7 . Unit Northampton MA 01060 Zef a Oven ay Di strict Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: 21 Stoddard St Marsha Pelletier Northampton MA 01060 yaTB(I'nnt) Curren,11,1.iilnr,ACr1reSs' s I la,t.l`k 617-831-6730 ",���ttrllj,,, _ 'Tet9prrora 2.2 Authorized Agent 4/Norther.:. Sol. 136 Elm St, Hatfield, MA 01038 Npfre(PnntJ Curren M iir�Addrd85' - . -1 413-247-6045 SignatureAlb , Tddph are gCTtON 3-ES .��M .tAlliipiti CTlQN�ill T!I Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building is)Building Permit Fee r 2. Electrical (b}Estimated Torai Cost at Construction from(B) 3. Plumbing Building Permit Fee 4. Mechanical(1-11lAC J r7( - 5. Fire Protection �/ 6. Total=(1 *2+3*4 *5) , $26,812 Cheat(Nurrater /25— 7 This Sadler Far Ofaalal Use Only^ Building Permit Nurnoe+:,r7P-a is I,1 II C ssusd: Signature: / .'Z Li- Z- ZOZ j Surging Cemmsaionerltrepector o''@urdstgs Date Section 4. ZONING Au informaticn must Be Completed. Permit Can Be Denied Due To incernplete information Existing Proposed Required by Zoning Thins:3*nm IL'b iilfrcl in by Buckling Deparznear. Lot Size Frontage Setbacks Front Sisic L R L: R. Rear . Budding Height Bldg. Square Footage L-1-1 Open Space Footage tiAkc ;Lord parkinaj fl 4 of Parking Ssaces FtLL (volurse it Lac 'atm") A. Has a Special Permit/Varfance/Finding ever been Issued for/on NO 0 DON'T KNOW YES 0 IF YES,date issued:[ IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES C. IF YES: enter Book Page aid lor Document#[ B. Does be site contain a brook, bud,' ut wale• or wetlands? NO DON"- ICNCV.' 0 YES 0 IF YES, has a permit been or need to be uotained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: C. Do any sN-s exist on the property? YES (Th. IF YES,describe size, type and location: _ D. Are there any proposed changes to or additions of signs intended for the Dr uDerty ? YES 0 NO IF YES, describe size, type and locution: E. Will the UMSITUdial actrvity tiskirio(a.=3'"g, xca...allon.or fillingl over 1 acre cr s : Part of a cornrrc-- plan that will disturb over 1 acre? YES 0 O_C IF YES.then a Northampton Storm Water Management Permit from the DPW is required_ SECTION S.DEURIPYlON OF PROPOSED PMFUS fchelrkal.apnttcablt) New House Q Addition ❑ Replacement Windows Altsrstlon(e) [J Roofing ❑ Or Doors Cl Acoeseory Bldg. 0 Demolition ❑ New Signe (0) Deck. l4 Siding l©l Other(peg anef Description of Proposed Install 24 solar panels on Roof Work: Arieretion of existing bedroom Yes No Adaing new bedroom Yes ro Attached Narratrve Renovating unfinished basement Yes No Plans Attached Roll -Sheet ea.,if house and or addition to exiatinsathou$Ino,Comph*,tls o110winA: a. Use of building :One minty _ Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. DOmensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Nu tuber of each g. Energy Conservation Compliance_ Masscheck Energy Compliance form attached? h. Type of construction Is construction within 100 It.of wetlands? Yes No. Is txonatrucbon within 100 yr. floodplain Yes No Depth of basement or cellar floor below finished grade k. Win building conform to the Building end Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Marsha Pelletier , as Owner of the subject property hereby authorize Northeast Solar bo s o my behalf,in all a ve to work authorized by this building permit application. t? ANN si ar rear Owner Date I, Gregory Garrison/Northeast Solar ,as OwneriAuthorized Agent hereby declare that the statements and inforrnabon on the foregoing application are true and accurate.to the best of my knowledge end; ef. Signed under the pains and penalties of perjury. Gre.o A.r ison Print ham / / 2 I Sig7a:ure of ova rr,h; . il� ' I Oatl v SECTION.9 -CONSTRUCTION SERVICES D.1 L,censed Constructio^ S,fpervlsor: Not Applicao e 0 Phi11_p Baunsgard Knoll:of Licerse Hotcar CS 1'J 5 113 - - Lioanne Nurrber 41 Heath Rd Colrain, Ya 01340 6/7/21 l4ddr Expirali:;i ._• 413-247-6045 one 9. Ra isierec -lame lni rcver"en: Ccnt•acto• Not Applicable 0 Northeast solar 169641 Company Name Regisirator Number 136 Elm S . Hatf ' e1d, Ma 01039 7/13/2021 Address Expiration Date tAlk, Telephone413-247-6045 SECTION 10-WOR11'- ,• PENSATION INSURANCE AFFIDAVIT (M.G.L.c. 152.§25C(6)) Workers Compensation Insurance affidavit must be cormieted and submttec w,th this applicabon. Failure to prc.:ce'r.s affidavit will result in the penal of the;ssuance of me building permit. Signed Affidavit Attached Yes.......X] Nc_._._. 0 11. - Home Owner Exemption The current exemption for"homeowners'.was extended to include Owner-occupied Dweillncs of one(I) or two(2)families and to allow such homeowner to engage an individual for hire who does not p,�ssess a license.provided that the owner acts as supervisor. CMMR 780, Sixth Edition Section 108.3.5.1 Definition of Homeowner: Person(a)who own a parcel of land on which hcfshc resides or intends to reside,oat whk h::ief is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and or faro: structures.A person who constructs more than one home In a two-year period shall not be considered a honteow ner. Such"homeowner"shall suhr.Jt:o the Building Official,on a form acceptable to the Building Official,that he,she shall be responsible for all such work performed under the buildin_permit. As acting Construction Supervisor your presence on the job sate will be required from time to time,during and upon completion of the work for which this pcimit is issued. Also be advised that with reference to Chapter 152(Workers"Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 5-tc,kUtn43, The debris will be transported by: or-11 w)l--- air (Irk The debris will be received by: ( jV -- Oa/ Building permit number: Name of Permit Applicant : 00/ b1 61(01 - 1421.,te gnature o ermit A licant µ - The Commonwealth of Massachusetts Department of Industrial Accidents _4 � C)fice of Investigations 1 Congress Street, Suite 100 t . Boston, MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/organization Name: Northeast Solar Address:136 Elm St. City/State/Zip:Hatfield, Ma 01038 Phone #:413-247-6046 Are you an employer?Check the app rop riate box: Business Type(requited): 1.0 I am a employer with 17 employees(full and/ 5. ❑Retail or part-time).* 6. ❑RestaurantBar/EatingEstablishmexrt 2.0 I am a sole proprietor or partnership and have no 7 El Office anchor Sales(incl. real estate, auto, etc.) employees working for m e in any capacity. [N o workers' comp.insurance required] 8. ❑Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑Entertainm end their tight of exemption per c. 152, §1(4), and we have 10.12 Manufacturing no employees. [No workers' comp. insurance required]** 4.0 We are anon-profit organization, staffed by volunteers, il.❑Healthcare with no employees. [No workers' comp. insurance req.] 12.0 Other *Any applicant that clucks box#1 mist also fill out the sectionbelvx sh wire their workers'currg,eisation policy information **If tlu corporate officers have exempted tlumselves,but the corporationhas otlerenmployees,a workers'compensation pairyis required and such an organization should cluck box#1. I am an employer that is providinng workers'compensation insurance for my employees. Below is the policy information. Insurance CcmpanyN ante:Gotham Insurance Company Insurer'sAddress: 21 Stoddard St City/State/zip: Northampton MA 01060 Policy# or Self-ins.Lic. m #WC201900019843 Expiration Date: 7/8/2021 Attach a copy of the workers' comp ensatio n p o licy declaration page (showing the p olicy number and exp iratio n date). Failure to secure coverage as required under Section25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. B e advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for ance coverage v rificaticn. I do hereby certify, under ; ns pen perfuy that the information provided above is trine arid correct. Signature: !/ Date: 9/28/2020 Phone# 413-247-604 Official use only. Do not write this area, to be completed by city or town official City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4.Licensing Board 5. Selectmen's Office 6. Other Contact Person: Phone#: ww5'n ssgo+tidia i"1 NORTSOL-01 MMONSINI ACORN CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) ki.—i 7/10/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Roblin Insurance Agency PHONE Fax iA c,No,Est):(781)455-0700 I(A/C,No):(781)449-8976 144 Gould Street Suite 100 Needham,MA 02494 aooREss:certfficates@roblininsurance.com INSURER(S)AFFORDING COVERAGE NAIC N INSURER A:Gotham Insurance Company INSURED INSURERB:Safety Insurance Company 39454 Northeast Solar Design Associates,LLC INSURER C:New York Marine and General Insurance Company 16608 136 Elm Street INSURERD: Hatfield,MA 01038 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL,iSUBR POUCY NUMBER POLICY EFF POLICY EXP LIMITS LTRINSD WVD (MMIDDIYYYYI (MM/DDIYYYYI A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR PK201900018166 7/8/2020 7/8/2021 DAMAGE O aocNTED ce) $ 300,000 PREMISSMED EXP(Any one person) $ 5,000 'PERSONAL&ADV INJURY I $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY X Pog LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ B AUTOMOBILE LIABILITY : COMBINED SINGLE LIMIT 1,000,000 (Ea accidents $ ANY AUTO 5909629 7/8/2020 7/8/2021 BODILY INJURY(Per person) $ OWNED ONLY X SCHEDULED I BODILY INJURY(Per accident) $ X AUTOS ONLY X AUTOS ONLY re?aident) GE $ 1 . $ A X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 1,000,000 EXCESS LIAB CLAIMS-MADE UM201900008269 7/8/2020 7/8/2021 AGGREGATE $ 1,000,000 DEC X RETENTION$ 10,000 3 C WORKERS COMPENSATION X I PER I OTH- AND EMPLOYERS'LIABILITY _STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE YIN WC201900019843 7/8/2020 7/8/2021 E.L.EACHACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Property PK201900018166 7/8/2020 7/8/2021 BPP 225,000 A Property PK201900018166 7/8/2020 7/8/2021 BI 350,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Issued as evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Cityof Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN P ACCORDANCE WITH THE POLICY PROVISIONS. 210 Main Street Northampton,MA 01060 AUTHORIZED REPRESENTATIVE y � ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD T T.! cc weahh of Massachusetts Division of Professional licensure Board of Building Regulations and Standards Constroators pervisor CS-106113 spires: 06/071"2U21 PHILLIP BA UNSG . 41 HEATH ROAD COl.RAJN MA 01 It -� Commissioner AlAift4)11 HOME IMPROVEMENT CONTRACTOR Registration valid for vidual use only TYPE:LLC before expiration If found return to: Re_ strn_ Expiration Office and Business Regulation 16964 07/13/2021 1000 -Suite 710 NORTHEAST SOLAR DESIGN ASSOC. 0211E GREGORY GARRISON 136 ELM ST e'mr ___ _ _. HATFIELD,MA 01038 Undersecretary valid tho nature ilk, kT Main electric •� 4 * 4003110,,, „ 0„...,..,• , panel on ' _ i , interior wall V A r m�t "? v. .0di • , Roof mounted solar array with ., • d 'le nd �s . x IQ Plu 72 2 US PT,. IiilLsr . microinverters PERK, "flPii` '141';\ '7,',,:: . i--- ...-..!- - 1------ ,e,ar, , , 4/1/4 f ',-'+ate. ,� -. ,i , .. �.; 4 - P crtki i 4TY`,1DGA kit"��jj �!� y ` �- tt tr -k ' t r L; a a.. � '' A,oPIPS. \ 4°7'7r , »y „ AVE OP "' "IF rr i t�ViI'N 1iO ��A '*sy, 4. } { 'r - w 3T A � w1' 'yki 7 Pelletier 21 Stoddard St Northampton, Ma 01060 1.1‘ Northeast Solar Vreeland Design Associates An integrative approach to design engineering and site planning Date: April 1, 2021 To: Justin Annis NorthEast Solar 136 Elm Street Hatfield, MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: Marsha and John Pelletier, 21 Stoddard St, Northampton, MA: Revised structural assessment of new house roofs to support proposed solar arrays. I have investigated the existing roof framing in the areas of the proposed PV solar panel installations and have reviewed the architectural and construction plans prepared by Habitat Post & Beam, South Deerfield. The contemporary 2-story, 20'x 71' house, fabricated by Habitat Post & Beam is presently under construction. 24 PV solar panels are to be installed on the southwest facing roofs; 6 solar panels on the 13' wide 2-story gable section, 12 panels on the 20' wide 2- story section and 6 panels on the 11'-9"wide 1-story garage section. The house roofs are framed with 2x12 rafters installed 24" on-center, spanning 6'-6"over the 13' wide section and spanning 10' over the 20' wide section with 10/12 roof pitches. 2x8 ceiling joists are attached to the bottom of the rafters on the 13' section and 2x12 ceiling joists are attached to the bottom of the rafters over the 20' wide 2-story section preventing those roofs from spreading. The garage roof is framed with 2x8 rafters installed 24"on-center, spanning 11'-6"with a 4/12 pitch. 2x8 ceiling joists are attached to the bottom of the rafters and to a 2x8 ledger at the house to prevent the roof from spreading. The roofing is composite asphalt shingles. I have reviewed the mounting details for the proposed solar array. Based on my calculations and a PV solar panel unit weight of 41± lbs, with the attachment points of the array placed at a maximum of 4' on center and staggered to minimize the load to any one rafter, and with snow guards installed on the main house roof with the 12 solar panels, the roof framing is adequate to support the proposed PV solar arrays and the snow and wind load requirements of the current MA State Building Code for the City of Northampton. Please contact me if you have any questions or need additional information. Sincerely, (\----Pk DFSASDAVID A. -# VREELAND r, CIVIL No. 46317 "' David Vreeland, PE v�� ��� Vreeland Design Associates 4S/ONA1.t4' 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 LG N ON®2 111111111111 360W I 355W I 350W The LG NeON 2 is one of the most powerful and versatile modules on the mar- ket today.Featuring LG's Cello Technology in monocrystalline n-type solar cells, the LG NeON®2 increases power output.Now includes a 25 years product and 90.1%performance warranty for higher performance and reliability. The new LG NeON®2 has been designed with aesthetics in mind using new cell design. DVE (1,10 us c App. 4 Feature Enhanced Performance Warranty Enhanced Product warranty 25 LG NeON® 2 has an enhanced performance LG has extended the warranty of the NeON®2 warranty. After 25 years,LG NeON®2 is guar- to 25 years,which is among the top of industry anteed to perform at minimum 90.1%of initial standards. performance. About LG Electronics G Electronics is a g,o ommitted to expanding its operations with the solar marker ne company first embarked on a solar energy source research program 1 1985 supportea by LG soups vast experience in the semi-conductor,LCD,chemistry and mat,als industries.In 2010,LG Solar successfully released its first Monaa° I_ LG series to the market,which is now available in 32 countries.The NeON°(previous.MonoX°NeON NeON°2,NeON°2 BiFacial wan the"Intersolar AWARD"in 2013,2015 L i and 2016,which demonstrates LG Solar's lead,innovation and commitment to the industry. --.. LG NeON®2 LG360N1C-N5 LG355N1C-N5 LG350N1C-N5 General Data Electrical Properties(STC*) Cell?rc,lerves(Matenal/Type) MonocrystaIline/N-type Model LG360N1C-N5 I LG355N1C-N5 LG350N1C-N5 Cell Maker LG Maximum Power(Pmax) [W] 360 355 350 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [VI 35.1 J 34.7 34.3 Number of Busbars 12EA MPP Current(Impp) [A] 10.28 ' 10.25 10.22 Module Dimensions(L x W x H) 1,700mm x 1,016mm x 40 mm Open Circuit Voltage(Vuc,!Sig) [V] 41.6 41.5 41.4 Weight 18.0 kg Short Circuit Current*,25%) [A] 10.84 10.80 10.76 Glass(Material) 'tempered Glass with AR Coating Module Efficiency [%j 20.8 20.6 20.3 Backsheet(Color) - White -- - Power Tolerance [%]I 0-+3 STC(Standard Test Condition).Irradiance 1000 W/m',Cell temperature 25*C,AM 1.5, Frame(Material) Anodized Aluminium Measurement Tolerance of Prnax ±3% Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes Cables(Length) 1,000 mm x 2EA Operating Conditions _ Connector(Type/Maker) MC 4/MC Operating Temperature [°C] -40-+90 Maximum System Voltage [V] I 1000(IEC) Maximum Series Fuse Rating [A] 20 Certifications and Warranty Mechanical Test Load*(Front) [Pa/psf] 5,400/113 IEC 61215-1/-1-1/2:2016,IEC 61730-1/2:2016 Mechanical Test Load'(Rear) i [Pa/psf]I 4,000/84 Certifications ISO 9001,ISO 14001,ISO 50001 *Based on IEC 61215-2.2016(Test Load-Design Load x Safety Factor(1.5)) OHSAS 18001 0 Mechanical Test Lands 5,000Pa/5,400Pa based on IEC 61215.2005 Salt Mist Corrosion Test I IEC 61701:2012 Severity 6 Ammonia Corrosion Test IEC 62716:2013 Packaging Configuration Hail Test 25mm(1")diameter at 23 m/s(52 mph) Number of Modules per Pallet [EA] 25 Number of Modules per 40k HQ Container [EA] i 650 Fire Rating Class C(UL 790) ------ -- Packaging Box Dimensions(L x W x H) [mm] 1,750 x 1,120 x 1,221 Solar Module Product Warranty 25 Years ----- Packaging Box Gross Weight [kg] 464 Solar Module Output Warranty Linear Warranty. *1)First year 98%2)After 1st year 0.33%annual degradation,3)90.1%for 25 years Dimensions(mm/inch) Temperature Characteristics NNlor [ °c] li 42 t3 ioi5.o,a0,0 Pmax [%/°C] I -0.34 Voc [WC] 0.26 or - +o.o n Sr Isc [%/C] ----_... .0.03-- - cro„°d',.a do es _1 ',VD I-(Nominal Module Operating Temperature).Irradiance 800 W/m',Ambient temperature 20°C, . . . . .. - Wind .. 1I t i,r,r,��e., Ii Wind speed I m/s,Spectrum AM LS Electrical Properties(NMOT) Model 'LG360N1C-N5 LG355N1C-NS' LG350N1C-N5 Maximum Power Pmax 270 I 256 263 ' ' MPP Voltage(Vmpp) [V) 33.0 32.6 32.2 1 MPP Current(Impp) ' [A] 8.20 8.17 8.15 Ti Ti Open Circuit Voltage(Voc) . [V] 39.2 39.1 I 39,0 o j o g Short Circuit Current(Isc) ; [A] 8.71 8.68 8,64 8, : 8 1-V Curves 12.0 1000W 0.0 I:L WOW a8.0 600W y 6.0 U 400W 200W 2.0 0.0 00 10,0 200 300 40.0 Voltage[V) ® LG LG Electronics Inc. Product specifications are subject to change without notice. Energy Business Division DS-NS-60-C-G-F-EN-200507 _ "y'4 LG Twin Towers,128 Yeoul-daero,Veongdeungpo-gu,Seoul TAEI T'+" 07336,Korea 02020 LG Electronics.All rights reserved. j Life ❑�s Good + wwwlg-solarcom Tech Brief 40.. k IRONRIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless / \ extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ��_ ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. r XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. �a Their superior spanning capability �, requires fewer roof attachments, --� reducing the number of roof �� penetrations and the amount of installation time. � � ", -- ,, , ,.. lilt (10 :iiiii -- . ice \ Force-Stabilizing Curve Sloped roofs generate both vertical and lateral - forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme % ' .'::;), / ..,„: weather and a longer system lifetime. 4, � Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000-series �,. ^ compatible with a range of tilt leg aluminum alloy,then protected with an r1 FlashFoot andoptions for flat anodized finish.Anodizing prevents surface 1 other pitched roof I 1 roof mounting and structural corrosion,while also providing attachments. applications. 1 a more attractive appearance. 1 Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow(PSF) Wind (MPH) 4' 5' 4" 6' 8' 10' 12' 90 120 None 140 XR10 160 90 120 20 140 160 90 30 160 90 40 -' 160 80 160 120 160 ' 'Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. ©2020 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.20 ���_ Cut Sheet - ASGU2 1. Installation to be completed in accordance with manufacturer's written specifications and installation instructions. 2. See spec sheet or contact manufacturer for detailed material, finishes, and configuration options. 3. Contact manufacturer for detailed layout. 4. Do not scale drawings. 5. Subject to change without notice. 1 1 /2" 7 [38.10mm] 7 i,1 0 ci 1 2" [50.80mm] t ' 3/8" -16 Tapped Hole 9/16" III [ 13.72mm] 1 1 /2" 7J8, [38.10mm] [22.86mm] 10 0 [____ 16' 10.54mm 3/8"-24 Tapped Hole I have verified that this clamp/bracket will fit the seam for this project. Quote#: Signature: Date: To confirm order,return signed cut sheet and sales quote. ALPINE SC EcoFasten Solar` 289 Harrel Street NOWGUARI k7 . Morrisville, VT 05661 Toll Free Phone 1.888.766.4273 Toll Free Phone 1.877.859.3947 Material: See Spec Sheet Toll Free Fax 1.888.766.9994 Toll Free Fax 1.888.766.9994 Scale: 1:1 3/16/2015 ASG: X EFS: -