15B-017 (2) 157 CHESTERFIELD RD SM-2021-0035 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 1048 Map: 15B 1�atirs: a Block: °17T_ SHEETMETAL PERMIT Lot: 001 Permit: SHEETMETAL Category: SHEETMETAL Permit# SM-2021-0035 PERMISSION IS HEREBY GRANTED TO: Project# JS-2021-001413 Est. Cost: $13,500.00 Contractor: License: Expires: Fee Charged:;$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2022 Balance Due:1$.00 Owner: HARDING CHRISTINE R #of Fixtures: Applicant: ROCK VALLEY HVAC DigSafe# AT: 157 CHESTERFIELD RD UseGroup ConstClass ISSUED ON: 23-Mar-2021 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: HVAC FOR RENOVATION THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. I e. • � 1 � I Signatur•; Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2021-002846 23-Mar-21 1416 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:Ihasbrouck@northamptonma.gov GeoTMS®2021 Des Lauriers Municipal Solutions,Inc. Commonwealth of Massachusetts ' etal Permit Date: 3/17/2021 / Permit#,;,�Y'/y7/—3 S Estimated Job Cost: $13 500 'Ar �� '�it,Fee: $ �j C� `l 10 do oA / Plans Submitted: YES N ?'ti��''�n, �`�� 'lan Reviewed: YES NO nti 4QpF Business License# 824 0,06co oN Aiplicant License# s Business Information: lrroperty Owner/Job Location Information: Name: Jesse Fortier(Rock Valley HVAC) Name: Tina Harding Street: 296C Nonotuck Street Street: 157 Chesterfield Rd. City/Town: Florence City/Town: Leeds Telephone: (413) 535-7804 Telephone: (413) 575-0777 Photo I.D. required/Copy of Photo I.D. attached: YES NO Stall Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family )( Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. /over 10,000 sq. ft. Number of Stories:2 Sheet metal work to be completed: New Work: 7- Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Remove existing gas forced air furnace. Provide and install American Standard HVAC system, AHRI reference #201813143 (see attached). Existing ductwork was terrible, sized improperly, and not insulated. We ripped that out and fabricated new system main trunk lines, new ductwork sealed and insulated to code. Added three system supply and three system returns to home. Sealed existing branch ductwork as good as possible, some branches run through a tight crawlspace. INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes "'No ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy • Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waives this requirement. Check One Only Owner • Agent ❑ Signature of Owner or Owner's Agent By checking this box., I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.\ Duct inspection required prior to insulation installation: YES NO /�- Progress Inspections / Date Comments Final Inspection Date Comments Type of License: By Master Title ❑ Master-Restricted City/Town _ ❑ Journeyperson Signature of Licensee Permit# ❑ Journeyperson-Restricted License Number: 3(1A?62 Fee$ ❑ Check at www.mass.gov/dpl , CsT 2/3Ya,1 pector Signature of Permit Ap. .val Project SummaryJob: Rock Valley Date: 3/1/2021 HEATING AND Entire House By: Wesley Fortier AIR CONDITIONING Rock Valley HVAC Inc. 296C Nonotuck Street,Florence,Ma 01062 Phone:(413)535-7804 Email:RockValleyHVAC@yahoo.com Web:wwwRockValleyHVAC.com License:SM2626 Pro'ect Information For: Harding Residence,Classic Colonial Homes 157 Chesterfield Rd.,Leeds,Ma 01053 Phone:(413)575-0777 Email:nate©cchonline.com Notes: Desi•n Information Weather: Greenfield(Worcester Dd),MA,US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 °F Daily range M Relative humidity 50 % Moisture difference 42 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 40552 Btuh Structure 20427 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40552 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 18384 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 0 Structure 2132 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1080 1080 Equipment latent load 2132 Btuh Volume(ft3) 9720 9720 Air changes/hour 0.90 0.47 Equipment Total Load(Sen+Lat) 20516 Btuh Equiv.AVF(cfm) 146 76 Req.total capacity at 0.70 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 1441 cfm Actual airflow 1441 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.071 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� C rsVhero OneDrse\De Right-Sute®Universal 2021 21.0.03 RSU24598 2021-Mar-171 Page sktop\CCH Leeds load.rup Calc=MJ8 Front Door faces: N N UMW LV->' 1"- -i\i ' 4-k.N k\ 11.11110 5%ti b %Caeca\ C uL i l \-0 isko.--Lc\ aim 4‘‘k-cliCO,A.c..-\,..)0( Level 1 .111 ,2 Er"tr Bath/Laundry 01 Cr f Stairs I'� f — Egt j 02nc-,f G`>c�' Living Room iiimmisomil sKrP 1 Y Closet l Li entry 2 i y girlillir I .1] Job#: 1 :47 Performed by Wesley Facer for: RockValey H VAC Inc. Scale:Pag z Haring Residarroe 293C NaldcYic Street FightSLte0lhuersa12021 157Chestefie1d Rd Raeroe;Ma 01062 21.0.03 FE17 24598 Leech,Ma 01053 PFme(413)535-7804 ove 1-W r p00 I Leeds bad.rup Phor (413)5750777 WON.Rcdalleii-NAC.ccm RodcValleyMAC@yatnacan r>te@adcriineccm N Level 2 Knee Wall 2nd floor bedroom [ n c1 r7°°C (a-) 5 PPC`l II (2? Knee Wall 2 Job#: Scale:1 :47 Performed by Wesley Forcer for: Rock Valey HVAC Inc. Page 1 Hari ngResideroe / NorntlrkStreet RhtSLle®Lhversa12021 157 Chaste-field Rd Acraroe,Ma 01062 21.0.03 F6L24598 2:2 1 2021 0v1ar-17 9:22 Leeds,Ma 01063 Pt e(413)5 -7804 ...Oiie\0eskop\172:2ds Leda* Flue(413)575-G777 vwwi.RCd<\tIleyl VAC.ccm Ro*ValleyH\AC@yatno.com rr{e@ochuiirecom This combination qualifies for a Federal Energy Efficiency Tax Credit when AI umbel placed in service between 1/1/2015 and 12/31/2020. ru ■.ail CERTIFIED' www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:201813143 Date:03-02-2021 Model Status:Active AHRI Type:RCU-A-CB(Split System:Air-Cooled Condensing Unit,Coil with Blower) Series:SILVER 16 Outdoor Unit Brand Name:AMERICAN STANDARD Outdoor Unit Model Number (Condenser or Single Package):4A7A6024J1 Indoor Unit Model Number(Evaporator and/or Air Handler):4TXCB004DS3 Furnace Model Number:S9V2B060U3VSA Region: All(AK,AL,AR,AZ,CA,CO,CT,DC,DE,FL,GA,HI,ID,IL, IA, IN,KS,KY, LA, MA,MD,ME,MI,MN,MO,MS, MT, NC,ND,NE,NH, NJ,NM, NV,NY,OH,OK,OR, PA,RI,SC,SD,TN,TX,UT,VA,VT,WA,WV,WI,WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1,2015 are eligible to be installed in all regions until June 30,2016.Beginning July 1,2016 central air conditioners can only be installed in region(s)for which they meet the regional efficiency requirement. The manufacturer of this AMERICAN STANDARD product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1,Performance Rating of Unitary Air-Conditioning &Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh:24000 SEER: 17.00 EER(A2)-Single or High Stage(95F) :14.00 1-"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published ratina is shown alone with the Previous(i.e.WAS)ratina. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2021 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 132591887226273283