Loading...
42-179 (4) 115 GLENDALE RD BP-2021-1054 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:42- 179 CITY OF NORTHAMPTON Lot:-1 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2021-1054 Project# JS-2021-001790 Est.Cost: $8862 00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: PIONEER VALLEY PHOTOVOLTAICS 111266 Lot Size(sq. ft.): Owner: PIONEER VALLEY HABITAT FOR HUMANITY Zoning: Applicant: PIONEER VALLEY PHOTOVOLTAICS AT: 115 GLENDALE RD Applicant Address: Phone: Insurance: 311 WELLS ST - SUITE B (413) 772-8788 Workers Compensation GREENFIELDMA01301 ISSUED ON:3/25/2021 0:00:00 TO PERFORM THE FOLLOWING WORK:INSTALL 22 PANEL 7.04 KW SOLAR ARRAY ON ROOF, INVERTER OUTSIDE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. I Q Certificate of Occupancy Signat e: FeeType: Date Paid: Amount: Building 3/25/202I0:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner (t -::::;) 4, tics s;2Uc1ueAL i,r-0 ir U _ 2• N I' CD : N` Si, The Commonwealth of Massachusetts 1 : Board of Building Regulations and Standards FOR �ti7 =- Massachusetts State Building Code,780 CMR MUNICIPALITY = USE = a (" Building Permit Application To Construct,Repair,Renovate Or Demolish a Revised Mar 2011 One-or Two-Family Dwelling This Section For Official Use Only —'if Building ermit Number: £P—a-i " (05Y Date Applied: ct,j� 55 `/Z 3-25-2o21 Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 115 Glendale Rd 1.1a Is this an accepted street?yes x no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: PIONEER VALLEY HABITAT FOR HUMANITY FLORENCE Name(Print) City,State,ZIP PO Box 60642 413-586-5430 megan@pvhabitat.org No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg.0 Number of Units Other ❑� Specify:Solar PV Brief Description of Proposed Work2:Installation of a roof mounted solar array SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $8,862.00 1. Building Permit Fee: $75. Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee 0 Total Project Costa(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire .$ Suppression) Total All Fees:$ Check No.�oZOY Check Amount: Cash Amount: 6.Total Project Cost: $8862 0 Paid in Full ❑Outstanding Balance Due: g0U4 a 44O PV Squared Solar I www.pvsquared.coop Phone:413-772-8788 I Fax:413-772-8668 311 Wells St.,Ste.B I Greenfield,MA 01301 4. $�`' MA Elec.Lic.A13764 I MA HIC 140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering, civil engineering, electricians, construction supervisors, roofers, and their associated helpers. We are a company that values training and education. We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by the January 30, 2009 Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that have followed. We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Maya Fulford Installation Manager SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-111266 03/14/2023 Daniel Gomez-Gonzalez License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 43 Hatfield Street No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft.) Northampton MA 01060 R Restricted I&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-772-8788 BUILDINGPERMITS@PVSQUARED.COOP I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 140077 9/15/2021 PIONEER VALLEY PHOTOVOLTAICS COOP HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 311 WELLS STREET BUILDINGPERMITS@PVSQUARED.COOP No.and Street Email address GREENFIELD MA 01301 413-772-8788 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes p No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Pioneer Valley Photovoltaics Cooperative to act on my behalf,in all matters relative to work authorized by this building permit application. SEE ATTACHMENT (A) Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. 3/18/21 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" attachment A PV Squared is committed to providing a high quality product and service and we look forward to working with you on your renewable energy project. Sincerely, Pioneer Valley PhotoVoltaics Cooperative Jonathan Child Design and Sales Team Attachments: A-PV Array Sketch General Terms and Conditions AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. I hereby authorize Pioneer Valley PhotoVoltaics Cooperative to proceed with the above-referenced Project in accordance with this Agreement. I further authorize Pioneer Valley PhotoVoltaics Cooperative, or its designated representative, to obtain required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be used by Pioneer Valley PhotoVoltaics Cooperative for marketing purposes. Megan McDonough August 7.2019 Executive Director Sign ure Pioneer Valley Habitat for Humanity, Inc. Proposal and Agreement#00015082 Page 5 of 10 Pioneer Valley Habitat for Humanity Inc.-August 7,2019 New England Construction Engineering, PLC 436 Campbell Street (NECE) Structural Construction Solutions White River Junction, VT 05001 Jonathan Rugg, P.E. 603-903-9798 j.rugg©NewEnglandConstructionEngineering.com March 24, 2021 Ms. Simone Audette Pioneer Valley PhotoVoltaics Cooperative, Inc. 311 Wells Street, Suite B Greenfield, MA 01301 Re: Habitat for Humanity House, Northampton NECE Project No. 21-001 T21 Dear Ms. Audette, At your request New England Construction Engineering, PLC (NECE) has reviewed the information that you provided on the proposed Habitat for Humanity house at 115 Glendale Road, in Northampton, MA.The purpose of the review was to provide an opinion regarding the roofs' capacity to support rooftop mounted solar panels. The information that you provided is attached to this letter for reference. You are proposing to mount PV panels on one side of the house roof. The proposed house measures 26'x36'. You have provided architectural plans by Austin Design Inc. These plans are dated October of 2020. You have also provided roof truss design and plan output from Universal Forest Products, dated June of 2020. The house is a one-story ranch with gable roof.The roof pitch is 6/12 The roof will be supported by manufactured wood roof trusses at 24 O.C. These trusses span 26' on the horizontal. The trusses have 2x6 top chords, and 2x4 bottom chords. All truss members are#2 SPF.The truss web members are 2x4, except the short, 2x6 verticals at the supporting walls which make up the "high heal". The trusses were designed for a top chord live load of 35psf.This top chord live load is the flat roof snow load (Pf). The truss design loads also include dead loads 20psf on the top chord and 10psf on the bottom chord. The roof will have a structural wood panel (Plywood or OSB) deck, and asphalt shingles. In providing this review and report, I assume that the house will be built as design, I further assume that the trusses will be properly installed, including required lateral bracing on truss T02, members 3-12 and 5-8, as shown on the truss plans, and diagonal bracing along members 4-11 and 4-12 at the gable ends. NECE's review included the controlling gravity load combination (snow and dead load). New England Construction Engineering, PLC PV Squared—Habitat for Humanity House Jonathan Rugg, P.E. 115 Glendale Road, Northampton, MA Page 2 of 2 Conclusion: Based on my review, I conclude that, property constructed as designed, the roof will support your proposed PV array. I base this on the following: the PV panels will be installed parallel to the roof, eliminating any additional wind load. The smooth surface of the proposed PV panels will shed snow more readily than the asphalt roofing. The ground snow load (Pg) for Northampton is 40 psf. The minimum flat roof load (Pf) is 35psf. According to the information that you provided; the proposed PV panels weigh approximately 2.3psf. In summary, the house roof will support your proposed PV array. Thank you for the opportunity to assist with this project. Please contact me if NECE can be of further assistance. Sincerely, JONATHAN A RUGG No. 51982 c* 22 /Jonathan Rugg, P.E. "eSS,, New England Construction Engineering, PLC. � ����• �'� '� Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Constr t i ti ,nvisor CS-111266 spires: 03)14/2023 DANIEL GOME2-GONZALEZ 43 HATFIELD'STREET NORTHAMPTON MA 01 . C kiikar Commissioner + . . , ,, . 77 Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card Registration: 140077 PIONEER VALLEY PHOTOVOLTAICS COOP Expiration: 09/15/2021 311 WELLS ST SUITE B GREENFIELD,MA 01301 Update Address and Return Card. SCA I 0 204.1.05r17 Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:Supplement Card before the expiration date. If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 140077 09/1512021 1000 Washington Street -Sufto710 PIONEER VALLEY PHOTOVOLTAICS COOP Boston,MA 02118 MAYA FULFORD 311 WELLS ST SUITE B 1,(,.a..w'f i ee••✓ GREENFIELD,MA 01301 Undersecretary of vali ithout slgna e DATE(MM/DDPNYY) ACORD CERTIFICATE OF LIABILITY INSURANCE 12/22/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Kathy Parker NAME: Webber&Grinnell PHONE (413)586-0111 FAX (413)586-6481 (A/C,No,Ext): (A/C,No): 8 North King Street E-MAIL kparker@webberandgrinnell.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# Northampton MA 01060 INSURER A: Ohio Casualty/Liberty 24074 INSURED INSURER B: Ohio Security/Liberty 24082 Pioneer Valley PhotoVoltaics Cooperative,Inc. INSURER C: Continental Indemnity/AUW Attn:Kim Pinkham INSURER D: 311 Wells Street,Suite B INSURER E: Greenfield MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER: CL20122214681 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD,WVD POLICY NUMBER (MMIDD/YYYY) (MM/DD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE IX OCCUR DAMAGE TO RENTED 300,000 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 15,000 A BKS57072282 01/01/2021 01/01/2022 PERSONAL aADvw uRv $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY PRO LOC PRODUCTS-COMP/OPAGG $ 2,000,000 PRO- OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) ANY AUTO BODILY INJURY(Per person) $ B OWNED X SCHEDULED BAS57072282 01/01/2021 01/01/2022 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE X AUTOS ONLY X AUTOS ONLY (Per accident) _ Underinsured motorist $ 300,000 UMBRELLA LIAB VV"'V""V "'y'v"""' 5,000,000 X _ OCCUR EACH OCCURRENCE _$ A EXCESS GAB CLAIMS-MADE US057072282 01/01/2021 01/01/2022 AGGREGATE $ 5,000,000 DED X RETENTION$ 10'000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 C OFFICER/MEMBER EXCLUDED? N N/A 375928710101 01/01/2021 01/01/2022 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Business Pers Property $1,820,700 Commercial Property A BKS57072282 01/01/2021 01/01/2022 Installation $25,000 Transportation $75,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Worker's compensation includes MA and NY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Proof of Insurance ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts *_ 1. Department of Industrial Accidents :el'_ 1 Congress Street,Suite 100 %3f:= Boston,MA 02114-2017 � www mass.gov/dia .. Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name(Business/Organization/Individual): Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address: 311 Wells Street, SuiteB City/State/Zip:Greenfield MA 01301 Phone#:413-772-8788 Are you an employer?Check the appropriate box: Type of project(required): LEI I am a employer with 48 employees(full and/or part-time).* 7. ❑New construction 2.11 I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] 3.01 am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. El Demolition 10 ❑Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.12 Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13. Roof repairs These sub-contractors have employees and have workers'comp.insurance.: p 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14.D Other See below: 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. $Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Continental Indemnity/AUW Policy#or Self-ins.Lic.#:37-592871-01-01 Expiration Date:03/14/2023 Job Site Address:115 Glendale Rd City/State/Zip: Florence MA 01039 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby ce :r t e,a' s 'nd penalties of perjury that the information provided above is true and correct Signatu . ►� ' 0110 Date: 3/18/21 Phone#:413-7 -87 8 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: PROJECT INFORMATION: N SOUq • Owner: Pioneer Valley Habitat a II) R4O for Humanity • Address: 115 Glendale Rd s��ef Northampton, MA 01060 �'"* a 5°y� PV Squared Solar • Phone: 413-218-0683 311 Wells Street,Suite B Greenfield,MA 01301 design@pv • Email: megan@pvhabitat.org 413-772-8788372. 788 JOB: Habitat 115 Glendale • System Size: 7.04 DC-STC SITE: 115 Glendale Rd • Modules: REC REC325NP - - - Northampton,MA 01060 • Rail: Ironridge XR100 REVISIONS: • Bases: EcoFasten Quickfoot • Snow Load: 40 lbs • Wind Speed: 117 mph ROOF STRUCTURE: • 26°Trusses @ 24"OC ®Site Plan No Scale ROOF MATERIAL: • Asphalt shingles Description Item Qty Ironridge XR100 Rail 168 BLACK XRL100-168BLK 8 PROJECT NOTES: Ironridge XR100 Rail 132 BLACK XRL100-132BLK 4 1. Framing location to be verified on site. Ironridge XR100 Splice SPLIC2 8 2. Slide rail assembly as needed to avoid Ironridge Universal Module Clamp BLACK UFO-CL-001-B 48 interfering with splices or bases. Ironridge Stopper Sleeve 30mm BLACK UFO-STP-30MM-B 8 3. Unless otherwise noted bases are staggered (1 Pair L/R) IR XR100 End Cap Rail XR100ENDCAP 24 TITLE: Site Plan and spaced not more than 48"O.C. Ironridge Low Profile Grounding Lug IRN GD-LUG-003 4 ____ 4. Additional or alternative bases may be used to meet actual roof conditions. Ironridge Plastic Clip TWO29-4000-077 44 FDN#: Wire Management Clip DCS-1307 88 BY: JG 1/4-20 x 3/4 T-Bolt OPT mount kiT IRN 29-50TB-005 22 DATE: 2/25/2021 QuikFoot AL Base QF-AL-M 40 QuikFoot Flashing BLACK QFL-BLK-812 40 SCALE: No Scale Slotted L-Foot3in BLACK SCL-101-3-ANODZD 40 SIZE: 8-1/2"x11" 5/16x3-1/8in fastener GRKRSS2 80 GEO-CEL clear PROFLEX26100 2 PV_0 1 °Mechanical Balance of System(MBOS) (Sheet 1 of 2) SOLAR'S MOST TRUSTED RE C .... REE 1011111111 N-PEAK 11111101111 SERIES11111111.000111111 PREMIUM MONO N-TYPE 11111111111111111111111111 SOLAR PANELS WITH SUPERIOR PERFORMANCE imilminillilligillill 1 , MONO N-TYPE:THE NO LIGHT INDUCED 4 r . r MOST EFFICIENT C-SI DEGRADATION TECHNOLOGY 111‘U r I $ t * kle � SUPER-STRONG FLEXIBLE FRAME UP TO 7000 PA INSTALLATION SNOW LOAD OPTIONS 4 ® .,,t: 1111111.1. IMPROVED GUARANTEED HIGH PERFORMANCE IN POWER OVER LIFETIME SHADED CONDITIONS 1111111111111111111 PRODUCT IMMIM _,\ i 330 /1 RED D 25 YEAR ) 3 PROTRUST m, /�/ MIMI rall P , WARRANTY .' POWERV 3,d�� Nu ELIGIBLE FOR REC N-PEAK SERIES 1675t2.5[65.94 1-0.1]_ DATA ► ..,28[1.1] 910[35.81 �� 382.5[15.05] ► k - e - Cell type: 120 half-cut n-type mono c-Si cells + I 6 strings of 20 cells in series "1000[39] - Glass: 0.13"(3.2 mm)solar glass with anti-reflection surface treatment Backsheet: Highly resistant polymeric _ construction Frame: Anodized aluminum(black) MJunction box: 3-part,3 bypass diodes,IP67 rated ul ,p . ,0IS 0 in accordance with IEC 62790 Cable: 12 AWG(4mmz)PV wire,39+4711 m+1.2 m) rg ^1 11t0.2 in accordance with EN 50618 , [[0.43 t0.81 +o r Connectors: StaubliMC4PV-KBT4/KST4,12AWG(4mm2) in accordance with IEC 62852 f: 20St0S IP68 only when connected Si i. ° [0.78 t0,081 in 1200[47] a Origin: Made in Singapore / />, a•' o .� MECHANICAL DATA Dimensions: 65.9 x 39.25 x 1.1" 1675 x 997 x 30 mm ► � 45[7.51 22.5(0.9] � 600 t1 123.6 i0.04] ( ) Area: 17.98ft2(1.67m2) I I 13011.181 Measurements in mm(inl Weight: 39.7 lbs(18 kg) LECTRICAL DATA-o STC Product code":RECxxxNP MAXIMUM RATINGS Nominal Power-PMAx(Wp) 305 310 315 320 325 330 Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 Operational temperature: 40...+85°C Nominal Power Voltage-VMPP(V) 33.3 33.6 33.9 34.2 34.4 34.6 Maximum system voltage: 1000V Nominal Power Current-IMpp(A) 9.17 9.24 9.31 9.37 9.46 9.55 Design load(+):snow 4666 Pa(97.5 Ibs/ft')' Open Circuit Voltage-Vac(V) 39.3 39.7 40.0 40.3 40.7 41.0 Maximumtestload(+): 7000Pa(1461bs/ftu)° Short Circuit Current-Isc(A) 10.06 10.12 10.17 10.22 10.28 10.33 Design load(-):wind 2666 Pa(55.7 lbs/ft2)' Maximum test load(-): 4000 Pa(83.5 Ibs/ftz)' °i Panel Efficiency(%) 18.3 18.6 18.9 19.2 19.5 19.8 G Max series fuse rating: 20 A Values at standard test conditions(STC:air mass AM I.5,irradiance 1000 W/m2,temperature 25'C),based on a production spread with a S' tolerance ofP,,,p,,Vac&Iscx3%within one watt class.'Where xxo indicates the nominal power class(P0 ()at STC above. Max reverse current: 20 A 'Calculated using a safetyfactorofl.5 m 'See installation manual for mounting instructions i. Product code':RECxxxNP 0 Nominal Power-PMAXP)(W 231 234 238 242 246 250 EMPERATURE RATINGS' d Nominal Power Voltage-VMpp(V) 31.1 31.4 31.7 32.0 32.2 32.4 >Nominal Operating Cell Temperature: 44°C(±2°c) Nominal Power Current 1,,,,,(A) 7.41 7.46 7.52 7.57 7.64 7.71 Temperature coefficient ofPMAx: -0.35%/°C s 11 Open Circuit Voltage-Voc(V) 36.7 37.1 37.4 37.7 38.0 38.3 °,Temperature coefficient ofVac: -0.27%/'C - Short Circuit Current-Isc(A) 8.13 8.17 8.21 8.25 8.30 8.34 'Temperature coefficient ofIsc' 0.04%/°C Nominal operating cell temperature(NOC T:air mass AM 1.5,irradiance 800 W/m2,temperature 20'C,windspeed 1 m/s). 'The temperature coefficients stated are linear values *Where xxx indicates the nominal power class(PM5x)at SIC above. 0 N ER LOW LIGHT BEHAVIOUR o w ® I�® Standard REC PIoTrust ypical low irradiance performance of module at STC. S C E ❑ InstalledbyanREC c us Certified Solar No Yes Yes o•- UL1703(Fire Type 2),IEC 61215,IEC 61730&UL1703;UL61730, Professional z o MCS 005,IEC 62804,IEC 61701,IEC 62716,IEC 62782 f ISO 9001:2015,ISO14001:2004,OHSA518001:2007 System size any 425kW 2S500kW a Product Warranty(yrs) 20 25 25 c ce PowerWarranty(yrs) 25 25 25 c, Labor Warranty(yrs) 0 25 10 a' Power in Yearl 98% 98% 98% Annual Degradation 0.5% 0.5% 0.5% Irradiance(W/m') Power inYear25 86% 86% 86% See warranty documents for details.Some conditions apply. REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean,affordable solar power in order to facilitate global energy transitions. Committed to quality and innovation,REC offers photovoltaic modules with leading high quality, ®4 backed by an exceptional low warranty claims rate of Tess than 100ppm.Founded in Norway in 1996, REC employs 2,000 people and has an annual solar panel capacity of 1.8 GW.With over 10 GW installed worldwide,REC is empowering more than 16 million people with clean solar energy.REC Group is a Bluestar Elkem company with headquarters in Norway,operational headquarters in www.recgroup.com Singapore,and regional bases in North America,Europe,and Asia-Pacific. 3/8 _---' T A 46 SERRATIONS i ± IL 1- ) , ._-_ :p / R1 /16" 1 7/8' 1/4" r 3/4„ 1/16 --1 R.005 R•010 Ail \ 2X R.01 — - -----gUr.}. ,,,,,,,, 60.00° 3/8"+-:006 / 1 /8" 002 y \/ 0 7/8" X 82° DETAIL A •X = +/- •1 SCALE 3:1 .XX = +/- .01 .XXX= +/- .005 289 Harrel Street pApMorrisville, VT 05661 SC --101 -3 i1� IEcoF'asten Solaro Toll Free Phone 1.888.766.9994 MATERIAL:O6000 SERIES ALUMINUM web www.ecofastensolar.com e-mail info@ecofastensolar.com SCALE: 1:1 1/6/2012 SHEET 1 OF 1 Cut Sheet ilfilk IRON RIDGE XR100 Bonded Splice ,::.10 " XR-100 RAIL ^ ` / 12.0 , it t O ItXR-100-SPLC-BD KIT, XR100 BONDED SPLICE IP 69 0 1) Splice, XR100, Mill 12" long 2) Screw, Self Drilling 1.24 Ili ♦ —0► .63 1.93mai .31 "\ -I o;Q=%;i1 �i 11u.t -I 0.42 .15 —..— .93 #12-14 TYPE "B"THREAD Property Value Property Value Material 6000 Series Aluminum Material 300 Series Stainless Steel Finish Mill Finish Clear vl.o %lk, Cut Sheet . .. IRONRIDGE XR100 Rail See Description / Length Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in' i .66 Section Modulus (X-axis) 0.297 in3 .46 Moment of Inertia (X-axis) 0.390 in4 J L. Moment of Inertia (Y-axis) 0.085 in° Torsional Constant 0.214 in3 Polar Moment of Inertia 0.126 in4 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) __ .58 1.2 L.- Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) 6000-Series 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 2D4" (17 Feet) Aluminum 1 1.60 lbs. vl.1