Loading...
38A-061 (27) 178 REAR WEST ST EQUESTRIAN BP-2020-1047 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38A-061 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: ALTERATION BUILDING PERMIT Permit# BP-2020-1047 Project# JS-2020-001775 Est_Ci : $30000.00 Fee:5210.00 PERMISSION IS J ERI 8 Y C•% :i N I ED TO: Const.Class: Contractor: Use Group: KEITER BUILDERS Lot Size(sq. ft.): Owner: SMITH C01.1 1 •!,[Jlzf?R Zoning: URC(110)/RR(0)/ Applicant: KEITER BUoi AT: 178 REAR\NES7c.„ Applicant Address: Insurance: 35 MAIN ST 4 1 ) WC FLORENCEMA01062 ISSUED ON:4/I4' 070 0:11/1:00 TO PERFORM THE FOLLOWING WORK:INSTALL 2 PORTABLE FREEZERS POST THIISCARO SO IT IS VISIBLE FROM THE STREET Inspector eat l'li:n►hn w_ Inspector of Wiring D.P.W. Building Inspector Undergronod: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final �✓ Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: • Final: 0.e. 6-5-2OZO ) •1? THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND RE�I,A,TIONS. oi-laemoN J /- Certificate of-Geetipartey Signature: FeeType: Date Paid: Amount: Building 4/14/2020 0:00:00 $210.00 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck---Building Commissioner City of Northampton Mail-Smith Freezers https://mail.google.com/mail/u/0?ik=2af6507c1c&view=pt&search.. l w I. City of lNorthampton - Jasmine Ward <jward@northamptonma.gov> Smith Freezers P1.4 AFprOved — Per Necift\ Di.reCte 9 messages MC�f ridi th 0$Leo r l� patrick Diggins <foodbuyr@smith.edu> Tue, Feb 11, 2020 at 3:45 PM To: Jasmine Ward <jward@northamptonma.gov> Hi Jasmine, As we discussed, this is the area we would like to put the freezer containers. We would remove the fence and clean up the pavement road way. The front edge of the containers would be at the edge of the blacktop drive extending out into the field. We would level the area with compacted gravel to rest the containers on. Deliveries would be received by me or another Dining Services staff member. Only full cases will be delivered to and taken from the site, so no card board or other waste will be stored around the area. We will have the containers, closed and locked at all times. If you need any other information please let me know. n a u • Thanks... Patrick Diggins Purchasing Manager/ Assistant of Business Operations Smith College Dining Services 30 Belmont Ave. Northampton, Ma. 01063 1 413 585 2311 Foodbuyr@smith.edu Jasmine Ward <jward@northamptonma.gov> Fri, Feb 14, 2020 at 10:01 AM To: Merridith O'Leary<moleary@northamptonma.gov> 1 of 4 2/24/2020,3:59 PM r i w. C 0 LD oar ST ° RAU � ‘14, xo CO CD CD --I40-ft REFRIGERATED CONTAINER 0 . , CIStandard Features '4,,,,,,f. .n"'"" '_ 40-ft(2,360 cu ft)Size r-�- -10°Fto70°FRange " 0 � j' Adjustable Thermostat - �0,1®®®��' `�'` Orli co 1 ~ 1� - ®M! /N, , Automatic Defrost , , { -' _' 0 Full Opening Swing Cargo Doors r--_ ., r 0 o Aluminum T-grade Floors om-- -- D t Stainless Steel Interior ' `' CO 3 Phase/230V or 460V/60Amps or 30Amps Our spacious 40-ft refrigerated units(reefers) hold twice as much �. Lockable Doors as our 20-ft reefers and are available for purchase and lease, in CD both new and used conditions. Rigid, high quality construction,and On-site Delivery double swing doors allow you to load and unload product with the aid of forklifts and pallet jacks. Unit Length Height Width Door Opening Exterior Interior Exterior Interior Exterior Interior Height Width US 40'0" 38'0 3/4,. 9'6" 8'3 5/8" 8'0" 7' S 5/8" 8'6 1/2„ 7' 5 58„ Metric(mm) 12,192 11,602 2,896 2,531 2,438 2,276 2,603 2,276 UnitTare Weight Payload Gross Weight Cubic Capacity lb 10,030 57,170 67,200 2,360 cu ft kg 4,550 25,930 30,480 66.8 cu m www.coldstorage2go.com info@coldstorage2go.com 1 . 800 . 732 . 2698 1/23/2020 TK Mag+CS.jpg ♦i 9 " / 11 Ti 4 4 44 5 ai' `tea �z: ¢. i RAVU660716 ' ' ll F 1 --,.. .:r �j/ 34.0p0O KG { I i E RA. UR. 7Y.7�V LB 3 k $$ 3 . . TARE 10.10f)LB , r s PAYLOAD t9.� a KG a 1 P �. . 2.394(UST, r , , , rs [1 ;, r' 1_...... . r I . a '• 1/1 https://mail.google.com/mail/u/0/#label/Kendall?projector-1 Carrier TRANS / COLD C Mod T bilejln GEN14-013 Rev A 11/04/2014 SUBJECT: Standby Specifications for Vector Units with Dual Voltage Transformer This General Bulletin replaces GEN12-004 released on 5/30/2012. Carrier Transicold has introduced a transformer for the Vector product line which will enable both 460VAC and 230VAC standby capability. Attached is an electrical specification sheet for Vector units operating on standby with or without the dual voltage transformer. Please take the opportunity to distribute this information to your customers. VECTOR 8100, 8500, 8600MT Starting unit S/N* Frame mount transformer kit PAX91377448 76-00861-00 *Prior to this s/n, Call Service Eng Hotline (800) 448-1661 VECTOR 5100, 6500, 6600MT Starting unit S/N* Frame mount transformer kit NAV91293657 76-02024-00 *Prior to this s/n, Call Service Eng Hotline (800) 448-1661 Applications Engineer NAO Truck/Trailer Group Truck/Trailer/Rail Service Engineering Athens, GA TD Rev A: Corrected the Service Eng Hotline number r 0 w f Carrier • Electrical Specifications & Minimum Standby Infrastructure for f TRANS/ COLD Carrier Transicold Vector units A I VECT • J ■ Vector 81/85/8600 Vector 81/85/8600 Standard 460V 230V with Optional Transformer Operating Voltage 460V/3ph/60Hz 208-230V/3ph/60Hz Full Load Amp Draw(FLA)* 22A 44A 230V primary, 22A 460V secondary Locked Rotor Amp Draw(LRA) 99A 198A primary, 99A secondary Electrical Receptacle IEC 309 pin &sleeve 480V, 30A, 4 wire, 3 pole, IEC 309 pin &sleeve 250V, 60A, 4 wire, 3 pole, IP67 rated IP67 rated(installed on the unit) (installed on primary side of transformer) Receptacle part number 22-04166-01 Receptacle, 22-04168-01 Cap 22-04231-00 Receptacle, 22-04232-00 Cap Phase Reversal Automatic Automatic Standby Circuit Breaker & Cordset Specifications Standby cable type &gauge SOOW, 600V, 90C, 10/4 (3ph + G) SOOW, 600V, 90C, 4/4(3ph +G) Recommended external circuit breaker 30A 60A Connector p/n 22-02944-00 Connector(cap included) 22-04167-02 connector(cap included)on 230V primary, 22-02944-00 connector(cap included) on 460V secondary *FLA is adjustable in the microprocessor configuration with a maximum of 22A (460V) Minimum Requirements for Standby Infrastructure 1. Ensure that the standby power installation is performed by a licensed electrician who is familiar with both local and national electric codes and requirements. 2. Each refrigeration unit must be protected by an individual circuit breaker sized per the appropriate unit electrical specification listed above. 3. A continuous earthing ground conductor must be provided at the plug and through the power cord to the refrigeration unit. 4. Carrier Transicold recommends that customers establish an Assured Equipment Grounding Conductor Program per the National Electric Code (NEC). Per the Assured Equipment Grounding Conductor Program, the NEC calls for all cordsets to be verified for ground continuity and correct wiring on a 3 month basis. 5. A neutral conductor MUST NOT be connected to the refrigeration units. All Carrier Transicold refrigeration units are balanced three phase systems;therefore, the unit only requires three phase wires and a ground conductor. 6. Standby power cordsets a. 460V cordsets between the circuit breaker and the refrigeration unit MUST be constructed from 10/4 SOOW cable. Carrier recommends a cable length between power source circuit breaker and refrigeration unit circuit breaker to be a minimum length of 50 feet to limit maximum fault currents and prevent damage to the power circuits with the unit. b. 230V cordsets between the circuit breaker and the refrigeration unit MUST be constructed from 4/4 SOOW cable. There is no minimum cable length requirement. For low voltage sources (208V+/-10%), do not exceed 85 feet. Attachment to GEN14-013 ( arrier Electrical Specifications & Minimum Standby Infrastructure for IR Carrier Transicold Vector units TRANS/ COLD 0 United Technologies l t f.�t :A—i VE'C TO MI 5100 6500 6601 : PM . . Vector 51/65/6600 Vector 51/65/6600 Standard 460V 230V with Optional Transformer Operating Voltage 460V/3ph/60Hz 208-230V/3ph/60Hz Full Load Amp Draw(FLA)* 25A 50A 230V primary, 25A 460V secondary Locked Rotor Amp Draw(LRA) 99A 198A primary, 99A secondary Electrical Receptacle IEC 309 pin &sleeve 480V, 30A, 4 wire, 3 pole, IEC 309 pin &sleeve 250V, 60A, 4 wire, 3 pole, IP67 rated IP67 rated(installed on the unit) (installed on primary side of transformer) Receptacle part number 22-04166-01 Receptacle, 22-04168-01 Cap 22-04231-00 Receptacle, 22-04232-00 Cap Phase Reversal Automatic Automatic Standby Circuit Breaker & Cordset Specifications Standby cable type&gauge SOOW, 600V, 90C, 10/4 (3ph + G) SOOW, 600V, 90C, 4/4 (3ph +G) Recommended external circuit breaker 30A _ 60A _ Connector p/n 22-02944-00 Connector(cap included) 22-04167-02 connector(cap included)on 230V primary, 22-02944-00 connector(cap included)on 460V secondary *FLA is adjustable in the microprocessor configuration with a maximum of 25A (460V) Minimum Requirements for Standby Infrastructure 1. Ensure that the standby power installation is performed by a licensed electrician who is familiar with both local and national electric codes and requirements. 2. Each refrigeration unit must be protected by an individual circuit breaker sized per the appropriate unit electrical specification listed above. 3. A continuous earthing ground conductor must be provided at the plug and through the power cord to the refrigeration unit. 4. Carrier Transicold recommends that customers establish an Assured Equipment Grounding Conductor Program per the National Electric Code (NEC). Per the Assured Equipment Grounding Conductor Program, the NEC calls for all cordsets to be verified for ground continuity and correct wiring on a 3 month basis. 5. A neutral conductor MUST NOT be connected to the refrigeration units. All Carrier Transicold refrigeration units are balanced three phase systems; therefore, the unit only requires three phase wires and a ground conductor. 6. Standby power cordsets a. 460V cordsets between the circuit breaker and the refrigeration unit MUST be constructed from 10/4 SOOW cable. Carrier recommends a cable length between power source circuit breaker and refrigeration unit circuit breaker to be a minimum length of 50 feet to limit maximum fault currents and prevent damage to the power circuits with the unit. b. 230V cordsets between the circuit breaker and the refrigeration unit MUST be constructed from 4/4 SOOW cable. There is no minimum cable length requirement. For low voltage sources (208V+/-10%), do not exceed 85 feet. Attachment to GEN14-013 i ( -2rrier Electrical Specifications & Minimum Standby Infrastructure for Carrier Transicold Vector units 6 TRANS / COLD 0' 14Na.Tioaalaylaa N.....s.....::::... . 22-04231-00 Receptacle 230V 22-04167-02 " 22-04232-00 Cap (not shown) Connector 230V AI ''a �e. v t te 22-04166-01 Receptacle 460V 22-04168-01 Cap (not shown) —111 22-02944-00 Connector 460V 10-00484-00 230V to 460V Transformer Attachment to GEN14-013