Loading...
Mechanical Plans-420 E Deer Springs WayDEHUMIDIFIER SUSPENDED A40018"ØCHECK-IN /RECPTIONASSOC.ENTRANCE /DELIVERIESTELLERSCASHROOMOFFICEELECTRICAL/DATA/ SECURITYEQUIPMENTSECURESTORAGERECEPTIONLOBBYSALESHALLWAYEF-1DDDDA400A400A300A300A300A300A400A200C200D200G600G200G800E1200B100B100F2506"Ø6"Ø6"Ø6"Ø10"Ø10"Ø10"Ø10"Ø 10"Ø8"Ø16"x14"16"x14"10"x6"10"x6"14"x12"14"x14"10"x6"10"x6"18"x16" 10"x10"SST16"x14"20"x16"10"ØUNISEXTOILETROOM122341065789121113FLEXIBLE DUCTMAX. LENGTH 5'-0".MANUAL VOLUMEDAMPER. (TYPICAL)BUILDINGSPRINKLER ROOMN.I.C.BUILDINGELECTRICAL ROOMN.I.C.LOUNGE10"x10"A40010"Ø14"x12"G200A2008"Ø14"x14"G40012"x8"A400E1200A40024"x16"16"x14"16"x14"14"x12"10"Ø10"Ø10"Ø10"ØTR ALCOVE14SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:NORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGSmm-dd-2020LANDLORD TENANT IMPROVEMENTSUITE 100M100MECHANICAL PLANPODSCALE:MECHANICAL PLAN 1/4" = 1'-0"THE MECHANICAL CONTRACTORS SHALL BE HELD TO HAVE REVIEWED ALLSHEETS OF THESE CONTRACT DOCUMENTS AND WILL BE RESPONSIBLE FORPERFORMING ALL WORK INDICATED ON ANY SHEET. THE MECHANICALCONTRACTORS WILL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITHTHE WORK OF OTHERS.REFER TO THIS SHEET AND SHEET M101 FOR MECHANICAL EQUIPMENTSCHEDULES, NOTES AND SHEET M300 FOR SPECIFICATIONS.REFER TO SHEET A200 FOR LOCATION OF DIFFUSERS IN THE REFLECTED CEILINGPLAN, AND FIRE RATING NOTES.COORDINATE ALL NEW DUCT ROUTING AND EQUIPMENT LOCATIONS WITHEXISTING BUILDING CONDITIONSTHE DUCTWORK SHALL BE SUPPORTED BY STRAP HANGERS AROUNDDUCTWORK. DO NOT SUPPORT DUCTWORK FROM METAL DECK.THE MECHANICAL CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONSPRIOR TO STARTING WORK AND ADJUST DUCTWORK, ETC... TO CORRESPOND TOTHE EXISTING CONDITION REQUIREMENTS.MECHANICAL CONTRACTOR TO MAINTAIN 10 FEET BETWEEN THE FRESH AIRINTAKE & ALL EXHAUST FANS, PLUMBING VENTS, ETC...TENANT SHALL FURNISH TWO (2) COPIES OF A CERTIFIED INDEPENDENT TEST &BALANCE REPORT BY A LICENSED AABC OR NEBB CONTRACTOR TO LANDLORD.ALL EQUIPMENT, PIPING AND ETC. EXPOSED INSIDE OR OUTSIDE BUILDING SHALLBE PAINTED WITH COLOR AS SELECTED BY ARCHITECT.HVAC CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS IN FIELDBEFORE CONSTRUCTION.PROVIDE ALL REQUIRED OFFSETS FOR DUCTWORK.THE RTU'S SHALL HAVE "CHARCOAL" 2" THICK AIR FILTERS. CONTRACTOR TOINSTALL ONE SET OF NEW FILTERS FOR ALL EQUIPMENT PRIOR TO OPENING.SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF CEILING DIFFUSERS ANDREGISTERS.PERFORM INSTALLATIONS IN ACCORDANCE TO LANDLORDS SPECIFICATIONS.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL SMOKE DETECTOR INRTU'S SUPPLY AIR DUCTWORK AND ELECTRICAL CONTRACTOR SHALL WIRE ANDTIE INTO FIRE PROTECTION SYSTEM AS REQUIRED.RTU SHALL BE CONTROLLED BY A HEATING/COOLING THERMOSTAT WITH REMOTESENSOR DURING OCCUPIED HOURS AS DETERMINED BY A TIME CLOCK. THESUPPLY FAN SHALL BE ENERGIZED AND OUTSIDE AIR DAMPER OPEN. ON A RISEIN ROOM TEMPERATURE FROM SETPOINT THE MECHANICAL REFRIGERATIONSHALL BE ENERGIZED TO PROVIDE SUFFICIENT COOLING. ON A DROP IN ROOMTEMPERATURE FROM SETPOINT THE HEAT PUMP HEAT SHALL BE ENERGIZED TOPROVIDE SUFFICIENT HEATING.DURING UNOCCUPIED HOURS OF OPERATION THE SUPPLY FAN SHALL BE OFFAND OUTSIDE AIR DAMPER SHUT. ALSO DURING UNOCCUPIED HOURS, A NIGHTTHERMOSTAT SHALL OVERRIDE THE TIME CLOCK FUNCTION AND CYCLE ON THEFAN AND HEATING ONLY.PROVIDE RELAYS AND ALL EQUIPMENT AS REQUIRED FOR CONNECTION TOLANDLORD SYSTEM.MECHANICAL CONTRACTOR TO STENCIL TENANT NAME AND SPACE NUMBER ONNEW ROOF MOUNTED UNIT.EF-1 EXHAUST FAN SHALL BE OPERATED FROM TOILET ROOM WALL LIGHTSWITCH.ALL ROOFING WORK IS TO BE PERFORMED BY LANDLORD'S ROOFINGCONTRACTOR AT TENANTS EXPENSE.TRAPPED CONDENSATE PIPING SHALL DISCHARGE ONTO ROOF ON SLASHBLOCK.MECHANICAL NOTES:6.5.4.2.3.1.1MECHANICAL CONTRACTOR TO COORDINATE WITH GENERAL CONTRACTORFOR 1" UNDERCUT DOOR.DUCT MOUNTED SMOKE DETECTOR IN SUPPLY AIR DUCT FURNISHED BYELECTRICAL CONTRACTOR, INSTALLED BY MECHANICAL CONTRACTOR ANDWIRED BY ELECTRICAL CONTRACTOR.REMOTE SENSOR LOCATION FOR RTU-1 WITH T'STAT CONTROL INPURCHASING. VERIFY EXACT LOCATION WITH THE SOURCE FIELDREPRESENTATIVE FOR CONFLICT WITH FIXTURES.REMOTE SENSOR LOCATION FOR RTU-2 WITH T'STAT CONTROL INPURCHASING. VERIFY EXACT LOCATION WITH THE SOURCE FIELDREPRESENTATIVE FOR CONFLICT WITH FIXTURES.CAP FULL SIZE RETURN AIR DUCT FROM RTU-2 AND STUB IN 18"x16, 10"x6 AND12"x8" RETURN AIR DUCTS.TRANSITION SUPPLY AIR CONNECTION FROM RTU-2 INTO A 30"x14" SUPPLY AIRDUCT IN DROP. TRANSITION AS NECESSARY. PROPORTIONALLY SPLIT THE30"x14" SUPPLY AIR DUCT INTO (1) 14"x14" AND (1) 16"x14" SUPPLY AIR DUCTS.TIE FULL SIZE RETURN AIR DUCT FROM RTU-1 INTO TOP OF NEW 24"x16"RETURN AIR DUCT.TRANSITION SUPPLY AIR CONNECTION FROM RTU-1 INTO A 20"x16" SUPPLY AIRDUCT IN DROP. TRANSITION AS NECESSARY.NEW CEILING MOUNTED EF-1 (100 CFM).MOUNT RETURN GRILLE IN CEILING SPACE AS HIGH AS POSSIBLE.COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH ARCHITECT.10"x10" EXHAUST AIR DUCT UP THRU ROOF IN PRE-FAB ROOF CURB ANDCONNECT TO EF-2. TRANSITION AS NECESSARY. SEE DRAWING M101 FORCONTINUATION.8"Ø EXHAUST AIR DUCT UP THRU ROOF AND TERMINATE WITH GOOSENECKWITH BIRD SCREEN. SEE DRAWING M101FOR CONTINUATION.THERMOSTATS LOCATION FOR RTU-1, & 2. MOUNT AT 48" ABOVE FINISH FLOOR.DEHUMIDIFIER PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR.APRILAIRE MODEL 1830, 70 PPD CAPACITY, 120 VOLT, 1 PHASE, 67 LBS., 3/4"DRAIN LINE. UNIT SHALL BE MOUNTED FROM THE STRUCTURE WITH ALLTHREADED RODS AND NEOPRENE VIBRATION ISOLATORS TIGHT TO UNDERSIDEOF THE CEILING.MECHANICAL PLAN KEY NOTES23456789ALL THERMOSTAT/SENSORS TO BE LOCATED 4'-0''ABOVE FINISHED FLOORS.WHERE THEROMSTATS/SENORS ARE LOCATED ONINTERIOR COLUMNS THEY SHOULD BE LOCATED ATREAR OF COLUMN WITH RELATION TO FRONT OF STORE.THERMOSTAT/SENSOR SHALL NOT BE LOCATED ONFEATURES WALLS OR VIGNETTES.THERMOSTAT/ SENSOR NOTES1.2.3.ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK,HANGERS, SUPPORTS, PIPING, AND ACCESSORIES SERVINGTHIS SPACE AND NOT INDICATED TO REMAIN SHALL BEREMOVED BY THE LANDLORD. LANDLORD SHALL REMOVEUN-USED ROOF CURBS AND PATCH ROOF. G.C. SHALL FIELDVERIFY EXISTING CONDITIONS PRIOR TO BID.DEMOLITION NOTE13.14.11.12.9.10.8.7.15.16.18.17.1011121319.20.21.1. ALUMINUM CONSTRUCTION RETURN/EXHAUST/TRANSFER GRILLES WITH BLADES SET AT 22.5 DEGREES FACING CEILING OR BACK WALL.2. PROVIDE WITH RAPID MOUNT FRAME SUITABLE FOR INSTALLATION IN DRYWALL TYPE CEILINGS, WHERE APPLICABLE.ACCEPTABLE ALTERNATE MANUFACTURERS: TITUS NOTE: ALTERNATES TO BE APPROVED BY ANTHROPOLOGIE PRIOR TO ORDERING.NOTES:MARK MODELMANUFACTURERFINISHNECK SIZE (L"xW")FACE SIZE (L"xW")FRAME TYPENOTESDAMPERNOISE CRITERIA LEVELACCESSORIES:EXT - EXTRACTOR, OBD - OPPOSED BLADE DAMPERDIFFUSER, REGISTER, LOUVER SCHEDULETYPEAD3. WALL MOUNTEDC4. DUCT MOUNTED (TO BE FLUSH MOUNTED WITH AIR EXTRACTORS INSTALLED)5. CEILING MOUNTEDFEGBPRICESURFACE MOUNTED1, 3<3063010"x6"11-3/4"x7-3/4"NONERETURN AIRGRILLESTANDARDOFF-WHITE FINISHPRICE<302, 5SPD12"x12"AS NOTEDOPPOSED BLADESURFACE MOUNTEDCEILING DIFFUSERSTANDARDOFF-WHITE FINISHPRICE<302, 5SPD24"x24"AS NOTEDOPPOSED BLADELAY-INCEILING DIFFUSERSTANDARDOFF-WHITE FINISHPRICESURFACE MOUNTED2, 5<308022"x22"21-3/4"x21-3/4"NONERETURN AIRGRILLESTANDARDOFF-WHITE FINISHPRICESURFACE MOUNTED1, 5<3063010"x10"11-3/4"x11-3/4"OPPOSED BLADEEXHAUST AIRGRILLESTANDARDOFF-WHITE FINISH6. CEILING MOUNTED WITH CONCEALED FRAME TYPE 22PRICE<303520D11-3/4"x7-3/4"10"x6"OPPOSED BLADESURFACE MOUNTEDSUPPLY AIR GRILLESTANDARDOFF-WHITE FINISHPRICESURFACE MOUNTED2, 5<308010"x22"11-3/4"x22-3/4"NONERETURN AIRGRILLESTANDARDOFF-WHITE FINISHHVAC SYMBOL LEGENDSYMBOLDESCRIPTIONABOVE FINISH FLOORAFFABOVE FINISHED GRADEABOVE FINISHED FLOORAFFAFGRETURN AIRSUPPLY AIREXHAUST AIRROOFTOP UNITLANDLORDMECHANICAL CONTRACTORGENERAL CONTRACTORELECTRICAL CONTRACTORPLUMBING CONTRACTORRASARTUEAPCMCGCLLECSUPPLY AIR DIFFUSERSSCHEDULE NUMBERMANUAL VOLUME DAMPERTHERMOSTATCFMRETURN AIR REGISTEREXHAUST FANEFUNDERCUT DOOR BY GCDDDUCT MOUNTED SMOKE DETECTORREMOTE SENSORSEAL CLASSSMACNAB (SEALAIRTIGHT)NOTE: ALL DUCTWORK SIZES ARE AIRWAY DIMENSIONSDUCTWORK SCHEDULESUPPLY AIRDUCTWORKRETURN AIRDUCTWORKEXHAUST AIRDUCTWORKDUCT SYSTEM1"SMACNAPRESSURE CLASS2"1"BBGALVANIZEDSTEELGALVANIZEDSTEELGALVANIZEDSTEELMATERIALDUCT22.14Exp:_____________PRO F E S S OINAL MECHANICALKEVIN K.HERBERTE NGINEER-STATEOFNEVADANo.15894 3-31-21 EF-2RTU-2 (120 MBH)1" GAS RISER UP THRU ROOFIN PIPING CURB & CONNECTTO RTU-1 COMPLETE WITHSHUT-OFF VALVE & DIRT LEG.1" GAS RISER UP THRU ROOFIN PIPING CURB & CONNECTTO RTU-2 COMPLETE WITHSHUT-OFF VALVE & DIRT LEG.NEW ROOF MTD.EXHAUST FAN(EF-2) (250 CFM).RTU-1 (120 MBH)6"Ø EXHAUST DUCTTO TERMINATEWITH GOOSENECKWITH BIRDSCREEN.SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:NORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGSmm-dd-2020LANDLORD TENANT IMPROVEMENTSUITE 100M101MECHANICALROOF PLANPODSCALE:MECHANICAL ROOF PLAN 1/4" = 1'-0"NOTE: MECHANICAL CONTRACTOR SHALLMAINTAIN A MINIMUM OF 10' DISTANCE FROMANY PLUMBING VENTS, EXHAUST DUCTS, ETC...FROM THE ROOFTOP UNITS INTAKE HOODS.BASE UNIT OPTIONS / ACCESSORES1) R-410A REFRIGERANT2) 5 YEAR WARRANTY ON COMPRESSORS & HEAT EXCHANGERS3) HINGED ACCESS DOORS2) DISCONNECT (BY ELECTRICAL CONTRACTOR)FIELD INSTALLED OPTIONS / ACCESSORES3) 120V CONVENIENCE OUTLET (BY ELECTRICAL CONTRACTOR) 4) ECONOMIZER WITH ULTRA LOW LEAKAGE DAMPERS5) ENTHALPY CONTROL & BAROMETRIC RELIEF8) 14" HIGH INSULATED ROOF CURB1) 2" THICK PLEATED FILTERS (2-SETS) PROVIDE MERV-8 FILTERS DURING CONSTRUCTION, REPLACE WITH CHARCOAL PRIOR TO AIR BALANCE AND INSTALL A FINAL SET OF CHARCOAL PRIOR TO STORE OPENING.4) MULTI-SPEED FAN MOTOR5) PHASE MONITOR, PHASE LOSE PROTECTION6) FAULT DETECTION AND DIAGNOSTICS7) CO2 SENSOR (WIRING ONLY) PHASE REVERSAL PROTECTION, PHASE BALANCE PROTECTIONDX COOLING COILVOLTS/Ø/HZMOTOR HPAPPROX. WEIGHT (LBS.)MCAMFSTOTAL (MBH)EAT (*FDB/WB)SENSIBLE (MBH)INPUT (MBH)OUTPUT (MBH)ELECTRICALGAS HEATINGMARK (RTU - #)AMBIENT OAT (*F)EXT. S.P. (IN W.C.)AIR FLOW (CFM)OA FLOW (CFM)MANUFACTURERMODEL1EERAFUE %NOMINAL TONSROOFTOP UNIT SCHEDULE208/3/60372.7513505012097.268.456.280/67.802400105360YHC074F313.1 EER81TRANE66) HAIL GUARDS7) 7 DAY PROGRAMMABLE THERMOSTAT WITH REMOTE SENSOR2208/3/60372.7513505012097.268.456.280/67.802400105360YHC074F313.1 EER81TRANE6EXHAUST FAN SCHEDULEBD - GRAVITY BACKDRAFT DAMPER, DS - DISCONNECT SWITCH, RC - 12" ROOF CURBNOTESNOTES:ACCESSORIES:MARK (EF-#)MANUFACTURERTYPEFAN SPEED (RPM)EXT. STATIC (IN W.C.)AIR FLOW (CFM)DRIVE TYPEPERFORMANCESERVESAPPOX. WEIGHT (LBS.)ACCESSORIESFAN MOTOR HP (WATTS)VOLTS/Ø/HZELECTRICALMODEL1. FAN SHALL BE CONTROLLED FROM LIGHT SWITCH AND WIRED BY ELECTRICAL CONTRACTOR. 2. UL/cUL 705 LISTED3. FAN SHALL BE INTERLOCKED WITH ROOFTOP UNIT SUCH THAT FAN IS OPERATING WHEN THE ROOFTOP UNIT IS IN AN OCCUPIED MODE.4. FAN SHALL BE FURNISHED AND INSTALLED WITH INTEGRAL (ON UNIT) SPEED CONTROLLERS FOR BALANCING PURPOSES.GREENHECK2, 3, 7SECURE STORAGE115/1/6020BD, DS, RC1/15 HP16980.375250DIRECTG-070-VGROOF MOUNTEDEXHAUST FAN5. ALUMINUM WHITE CEILING GRILLE. 6. HANGING VIBRATION ISOLATOR KIT.211, 2, 4, 5, 6UNISEX RESTROOM115/1/6015BD, DS128 WATTS7560.375100GREENHECKDIRECTSP-B150CEILING MOUNTEDEXHAUST FAN7. VARI-GREEN EC MOTOR WITH DIAL FOR BALANCINGExp:_____________PRO F E S S OINAL MECHANICALKEVIN K.HERBERTE NGINEER-STATEOFNEVADANo.15894 3-31-21 RETURN TAPSUPPLY TAPLONG RADIUS ELBOWSCALE:NONEM200SUPPLY AIR FLEX DUCT DETAIL1SCALE:NONEM200RECTANGULAR DUCT SUPPORT DETAIL - CONCEALED4SCALE:NONEM200DUCTWORK DETAILS2SUPPLY TAP WITHSUPPLY REGISTERSCALE:NONEM200DIFFUSER CONNECTION DETAIL- FLEX DUCT5SCALE:NONEM200EXHAUST FAN DETAIL3SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:NORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGSmm-dd-2020LANDLORD TENANT IMPROVEMENTSUITE 100M200PODMECHANICALDETAILS &SCHEDULES123070 SF(1 PERSON)((5 CFM PER PERSON) +(.06 CFM PER SF)) x 1.25CASH ROOM33040 SF(.06 CFM PER SF) x 1.25DATA ROOMVENTILATION SCHEDULEOAREQUIRED(CFM)OASUPPLIED(CFM)REMARKSHVACUNITAREASERVEDOCCUPANTLOADREQUIREDVENTILATION1100 SF350315((7.5 CFM PER PERSON) +(.12 CFM PER SF)) x 1.25(16 PEOPLE)455(2 PEOPLE)((5 CFM PER PERSON) +(.06 CFM PER SF)) x 1.2512047STORAGESECURE1960255 SFHALLWAY15340 SF(.06 CFM PER SF) x 1.25DELIVERIES193085 SF(2 PEOPLE)((5 CFM PER PERSON) +(.06 CFM PER SF)) x 1.25OFFICE(1 WC)70 CFMEXHAUST70 CFM PER WCRESTROOMUNISEX100 CFMEXHAUST455 SF-STORAGESECURE250 CFMEXHAUST– 15 CFM OAFROM RTU-2RTU-1RTU-2RTU-2RTU-2RTU-2RTU-2RTU-2EF-1EF-2SALES /RECEPTION /CHECK-IN205 SF6059((7.5 CFM PER PERSON) +(.12 CFM PER SF)) x 1.25(3 PEOPLE)TELLERSRTU-2(.06 CFM PER SF) x 1.25480720TOTALSRTU-131035 SFTR ALCOVE(.06 CFM PER SF) x 1.25Exp:_____________PRO F E S S OINAL MECHANICALKEVIN K.HERBERTE NGI NEER-STATEOFNEVADANo.158943-31-21 SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:NORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGSmm-dd-2020LANDLORD TENANT IMPROVEMENTSUITE 100M300PODMECHANICALSPECIFICATIONS1. GENERAL NOTES:IF ANY DISCREPANCY EXISTS BETWEEN THESE DOCUMENTS, MECHANICAL CONTRACTOR MUSTREQUEST IN WRITING, CLARIFICATION FROM URBAN OUTFITTER'S, INC. ARCHITECT AND ENGINEER.1. BY SUBMITTING A QUOTATION OR PROPOSAL, THE MECHANICAL CONTRACTOR EXPRESSLY STATESAND WARRANTS THAT: ALL DRAWINGS AND SPECIFICATIONS HAVE BEEN THOROUGHLY REVIEWED,CONTRACTOR HAS BECOME FAMILIARIZED WITH JOB SITE CONDITIONS AND IS TOTALLY QUALIFIED TOPERFORM ALL OF THE WORK REQUIRED.2. BEFORE SUBMITTING A FINAL PROPOSAL, THE CONTRACTOR SHALL EXAMINE THE SITE OF THEPROPOSED WORK TO DETERMINE THE EXISTING CONDITIONS THAT MAY AFFECT THE PROPOSAL. IFDISCREPANCIES ARE NOTED BETWEEN THE DOCUMENTS AND THE EXISTING CONDITIONS THEARCHITECT SHALL BE NOTIFIED AND THE CONTRACTOR SHALL RECEIVE CLARIFICATION BEFORESUBMITTING A BID. THE SUBMISSION OF A PROPOSAL SHALL INDICATE THAT ALL CHARGES AND COSTSMADE NECESSARY BY EXISTING CONDITIONS ARE INCLUDED AND THAT THE COMPLETE SYSTEM ASDESCRIBED ABOVE WILL BE FURNISHED AT THE PROPOSED COST.3. IF WORK IS NOT SPECIFIED BUT REQUIRED BY CODE, THE WORK SHALL BE PROVIDED BY THECONTRACTOR WITHOUT ADDITIONAL EXPENSE TO THE OWNER.4. IT IS THE INTENT OF THESE SPECIFICATIONS TO PROVIDE A COMPLETE, FINISHED, TESTED, ADJUSTEDAND OPERATIONAL MECHANICAL SYSTEM. ANY APPARATUS, MATERIAL, WORK OR INCIDENTAL ITEMSREQUIRED TO MAKE THE SYSTEM COMPLETE AND READY FOR OPERATION SHALL BE INCLUDED IN THEMECHANICAL CONTRACTOR'S PROPOSAL WHETHER OR NOT IT IS SHOWN ON THE DRAWINGS OR IN THESPECIFICATIONS.5. THE LANDLORD'S "TENANT CRITERIA MANUAL" FORMS A PART OF THESE SPECIFICATIONS. ANYDISCREPANCY BETWEEN THESE SPECIFICATIONS AND THE "TENANT CRITERIA MANUAL" THE ARCHITECTSHALL BE NOTIFIED IMEDIATELY. ANY EQUIPMENT REQUIRED OF THE MANUAL BUT NOT SHOWN ONTHESE SPECIFICATIONS SHALL BE PROVIDED AT THIS CONTRACTOR'S EXPENSE. THE CONTRACTOR ISRESPONSIBLE FOR SECURING A COPY OF THE TENANT CRITERIA MANUAL FROM THE LANDLORD ANDBECOMING FAMILIAR WITH ITS CONTENTS.6. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC. THEY ARE INTENDED TO CONVEY THE SCOPE OFWORK AND TO INDICATE THE GENERAL ARRANGEMENT OF THE EQUIPMENT, DUCTS, PIPING, ETC. THEMECHANICAL CONTRACTOR MUST OBTAIN APPROVED CONSTRUCTION DRAWINGS FROM THE GENERALCONTRACTOR BEFORE BEGINNING ANY WORK.7. THE ENTIRE INSTALLATION, INCLUDING ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP, SHALLCONFORM TO ALL APPLICABLE LAWS, CODES AND REGULATIONS OF MUNICIPAL, COUNTY, STATE ANDFEDERAL AUTHORITIES AND SHALL ALSO BE IN COMPLIANCE WITH THE LANDLORD'S CRITERIA AND THELATEST EDITIONS OF ASHRAE STANDARDS, THE LIFE SAFETY CODE, THE STANDARD BUILDING CODE,UNDERWRITERS LABORATORIES, THE NATIONAL ELECTRICAL CODE, NFPA 1 (AS APPLICABLE) 70, 90A,AND 96.8. THE MECHANICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS ANDLICENSES PERTAINING TO HIS WORK.9. THE CONTRACTOR SHALL OBTAIN AND COMPLY WITH DETAILED REQUIREMENTS OF LEASE EXTRACTSFROM THE LANDLORD AND TENANT.10. THE CONTRACTOR SHALL FURNISH AND INSTALL AN AIR-CONDITIONING AND HEATING SYSTEM INACCORDANCE WITH LANDLORD CRITERIA.11. COORDINATE LOCATIONS OF ALL AIR OUTLETS WITH ALL WALLS, LIGHTS, SPRINKLER HEADS, CEILINGTILES AND DECORATIVE CEILING FIXTURES PRIOR TO INSTALLATION.12. ALL WORK SHALL BE DONE WITH A MINIMUM OF NOISE AND DISTURBANCE TO BUSINESS ROUTINE.ALL WORK SCHEDULES SHALL BE COORDINATED WITH AND APPROVED BY, THE ARCHITECT.13. SINCE THESE ARE SECURE FLOORS, ALL DELIVERIES, WORKERS, WORK OPERATORS, ETC.,REQUIRED BY THE CONTRACTOR FOR WORK PERFORMED IN ANY AREA OR SITE BUILDING SHALL BE INSTRICT CONFORMANCE TO THE RULES AND REGULATIONS OF THE OWNER AND ARCHITECT.14. CONTRACTOR SHALL PROTECT HIS WORK AND EQUIPMENT FROM DAMAGE, VANDALS, ETC. ANY ITEMTHAT IS DAMAGED, VANDALIZED OR STOLEN PRIOR TO ACCEPTANCE OF BUILDING BY OWNER ANDARCHITECT SHALL BE REPLACED BY RESPECTIVE CONTRACTOR AT NO CHARGE TO OWNER.15. PROVIDE ACCESS DOORS FOR ALL CONCEALED TURNING VANES IN DUCTWORK, VALVES, VENTS,DAMPERS, FIRE DAMPERS, EXPANSION JOINTS, PULL BOXES, SHOCK ABSORBERS, DRAINS, MOTORS,FANS, PUMPS AND ANY OTHER ITEM REQUIRING SERVICE. DOORS IN PLASTER OR CONCRETE SURFACESSHALL HAVE A RECESSED DOOR WITH CONCRETE OR PLASTER FACING. DOORS IN CARPETED OR TILEDAREAS SHALL BE RECESSED WITH TILE FACING. NO ACCESS DOORS ARE REQUIRED IN 2' X 2' AND 2' X 4'LAY-IN ACOUSTIC TILE CEILING. PROVIDE COLORED PINS TO DENOTE ACCESS TILES. FURNISH FACTORYMADE METAL ACCESS DOORS, COMPLETELY FLUSH, "ALLAN HEAD" SCREWDRIVER OPERATED, WITHFRAMES AND CAM-TYPE CATCH WITH STAINLESS STEEL STUD. DOORS SHALL BE NOT LESS THAN 12" X12" FOR HAND ACCESS. DOORS IN WALLS AND CEILING SHALL BE PRIME COATED CARBON STEEL.FURNISH FIRE RATED DOORS FOR FIRE RATED CONSTRUCTION. RATING OF DOOR MUST BE SAMERATING AS CONSTRUCTION.16. IT IS SPECIFICALLY THE INTENTION OF THIS SPECIFICATION TO HOLD THE CONTRACTORRESPONSIBLE FOR ALL DAMAGE DONE TO ANY EXISTING FACILITIES, EQUIPMENT, PAINTING, ORARCHITECTURAL AND STRUCTURAL FEATURES OF THE BUILDING, BY EITHER THEIR OWN WORKMEN ORBY ANY OF THEIR SUBCONTRACTORS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE DONE BY HIS OWNWORKMEN OR SUBCONTRACTORS, AND THE OWNER AT HIS DISCRETION, MAY WITHHOLD PAYMENTSEQUAL TO THE REASONABLE COST OF THE REPAIRS.17. THIS CONTRACTOR SHALL NOT INTERRUPT ANY OF THE SERVICES OF THE EXISTING BUILDING NORINTERFERE WITH THE SERVICES IN ANY WAY WITHOUT THE EXPRESSED PERMISSION OF THE OWNERAND ARCHITECT.18. THIS CONTRACTOR OR HIS WORKMEN SHALL NOT BE PERMITTED TO USE ANY PART OF THE EXISTINGBUILDING AS A SHOP WITHOUT THE APPROVAL OF THE OWNER AND ARCHITECT.19. WHERE THE WORK MAKES TEMPORARY SHUTDOWN OF SERVICES UNAVOIDABLE, THEY SHALL BEMADE AT NIGHT OR AT SUCH TIMES AS WILL CAUSE THE LEAST INTERFERENCE WITH THE ESTABLISHEDOPERATING ROUTINE.20. THIS CONTRACTOR SHALL ARRANGE THE WORK SO AS TO ASSURE THAT SERVICES WILL BE SHUTDOWN ONLY DURING THE TIME ACTUALLY REQUIRED TO MAKE THE NECESSARY CONNECTION TO THEEXISTING WORK. THIS CONTRACTOR SHALL GIVE AMPLE WRITTEN NOTICE IN ADVANCE TO THE OWNEROF ANY REQUIRED SHUT DOWN.21. ALL MOTORS, FANS, CONTROLS, FIXTURES, HVAC UNIT, DUCTWORK AND OTHER EQUIPMENT FORUSE IN THIS CONTRACT SHALL BE PROTECTED BY TARPAULIN OR BY BOXING AS SOON AS DELIVEREDTO THE SITE, AND SHALL BE KEPT CLEAN AND DRY. THE MOTORS, UNITS, FIXTURES, FANS, DUCTWORKAND MOVING PARTS SHALL BE KEPT COVERED SO AS TO ELIMINATE DIRT, DUST, AND OTHER MATERIALSENTERING THE PARTS DURING ERECTION AND CONSTRUCTION WORK ON THE BUILDING. SHOULD IT BEFOUND THAT ANY PARTS ARE DAMAGED DUE TO CARELESSNESS ON THE PART OF THE CONTRACTOR INNOT PROVIDING PROPER PROTECTION, SUCH PART OR PARTS SHALL BE REPLACED BY THECONTRACTOR AT HIS OWN COST AND EXPENSE. ALL OPENINGS IN DUCTS, PIPING, CONDUITS, ETC.,SHALL BE PROPERLY PROTECTED WITH TEMPORARY CAPS OR PLUGS AT ALL TIMES.22. THE MECHANICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL METHODS OF HANGING,SUPPORTING, CUTTING AND PATCHING WITH THE OWNER OR LANDLORD.23. DURING THE CONSTRUCTION PHASE OF THE PROJECT, ANY DUCTWORK INSTALLED IS TO BECOMPLETELY SEALED UP OF ANY OPENINGS, EITHER AT THE BEGINNING OR END OF A DUCT RUN OR AT ABRANCH, COLLAR DIFFUSER OR REGISTER TO AVOID DIRT OR OTHER CONTAMINANTS FROM ENTERINGTHE SYSTEM.24. CONTROL WIRING AND CONTROLS: THE MECHANICAL CONTRACTOR IS TO FURNISH AND INSTALL ALLNECESSARY WIRING (IN CONDUIT) AND CONTROLS REQUIRED TO PROVIDE A COMPLETE AND OPERATINGSYSTEM.25. POWER WIRING: A. THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL ALL EQUIPMENT AND MATERIAL REQUIRED TO PROVIDE POWER TO THE MECHANICAL EQUIPMENT FROM THE TENANT'S POWER SUPPLY. B. THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A DISCONNECT SWITCH AND STARTER ON THE MECHANICAL EQUIPMENT AS NECESSARY FOR A COMPLETE INSTALLATION. C. THE ELECTRICAL CONTRACTOR IS TO PROVIDE POWER WIRING TO THE TOILET EXHAUST FAN THROUGH THE TOILET ROOM LIGHT SWITCH WITH DELAY OFF BUILT IN.26. THIS CONTRACTOR IS TO HIRE LANDLORD'S SPECIFIED CONTRACTOR FOR ALL ROOF PENETRATIONS.27. IF STRUCTURAL DRAWINGS FOR HVAC EQUIPMENT SUPPORT(S) ARE NOT ALREADY INCORPORATEDINTO THIS SET OF PLANS AND SPECIFICATIONS, THE MECHANICAL CONTRACTOR, AT THEIR OWN COSTAND EXPENSE, AND AS PART OF THE BID TO THE G.C., IS TO HIRE A STRUCTURAL ENGINEER TO DESIGNTHE SUPPORTS FOR THE NEW HVAC UNITS AND A STRUCTURAL SUBCONTRACTOR TO FURNISH ANDINSTALL SUCH HANGERS / SUPPORTS, BRACING, ETC. TO HANG FROM THE STRUCTURE FOR ALL NEWHVAC EQUIPMENT. G.C. TO SUBMIT AS REQUIRED ALL STRUCTURAL SHOP DRAWINGS TO THE LANDLORD'SARCHITECT, AS REQUIRED, FOR APPROVAL, PRIOR TO STARTING WORK.28. MECHANICAL CONTRACTOR SHALL PROVIDE A COMPLETE AIR BALANCE OF ALL SYSTEMS ASREQUIRED PER PROJECT.29. ALL DUCTWORK MUST HAVE MARKERS AND DIRECTION ARROWS EVERY 15 FEET PER INDUSTRYSTANDARD, EXCEPT THROUGHOUT CUSTOMER/RETAIL AREAS WHERE DUCT/PIPING IS EXPOSED.II. DRAWINGS1. SUBMIT TWO (2) SETS OF AS BUILT DRAWINGS IDENTIFIED WITH PROJECT NAME AND LOCATION, TO THEARCHITECT OF RECORD, OF THE FOLLOWING: 1. DUCTWORK LAYOUT 2. CONTROL DIAGRAMS 3. SEQUENCE OF OPERATION 4. EXHAST FANS & HVAC UNITS 5. AIR OUTLETS 6. INSULATION2. AS-BUILT DRAWINGS ARE NOT A SUBSTITUTE FOR SHOP DRAWINGS AND SHOULD NOT BE CONSIDEREDTHE SAME.III. GUARANTEE, WARRANTY1. THE MECHANICAL CONTRACTOR SHALL INCLUDE IN THE PROPOSAL A ONE YEAR GUARANTEE,WARRANTY ON ALL EQUIPMENT AND MATERIAL HE INSTALLS OR REFURBISHES UNLESS A LONGERWARRANTY IS INDICATED FOR EQUIPMENT (IE: COMPRESSOR TO HAVE A MINIMUM FIVE (5) YEARWARRANTY)..IV. DUCTWORK1. THE MECHANICAL CONTRACTOR SHALL PROVIDE COMPLETE AIR BALANCING OF ALL NEW SYSTEMS.TESTING AND BALANCING SHALL BE PERFORMED BY AN INDEPENDENT CONTRACTOR AT MECHANICALCONTRACTOR'S EXPENSE. ALL NEW SYSTEMS SHALL BE BALANCED IN ACCORDANCE WITH THE LATESTSTANDARD OF THE "ASSOCIATED AIR BALANCE COUNCIL" (AABC) OR "THE NATIONAL ENVIRONMENTALBALANCING BUREAU" (NEBB), NO SUBSTITUTIONS WILL BE ACCEPTABLE. A COMPLETE CERTIFIED REPORTINDICATING AIR FLOW RATES, PRESSURE DROPS, STATIC PRESSURES, BRAKE HORSEPOWER, AMP DRAW,EXHAUST CFM, ETC., SHALL BE DELIVERED TO THE ARCHITECT, THE TENANT AND THE MALL MANAGEMENTOFFICE. ACTUAL AIR BALANCING SHALL BE PERFORMED WITH A 98% ACCURATE AIR VELOCITY METER.2. CHANGE IN DIRECTION ELBOWS SHALL HAVE AN INSIDE RADIUS OF NOT LESS THAN THE WIDTH OF THEDUCT.3. ALL DUCTWORK SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH SMACNA LOW VELOCITYAND "HVAC DUCT CONSTRUCTION STANDARDS MANUAL", LATEST EDITION AND ASHRAE USING PRIMESHEETS OF GALVANIZED STEEL. ALL SQUARE ELBOWS SHALL BE PROVIDED WITH DOUBLE WALLED VANESON MAXIMUM 3" CENTERS. PROVIDE SEAL CLASS "C" ON ALL TRAVERSE JOINTS UNLESS SUPERSEDED BYMORE STRINGENT LOCAL CODES. ALL DUCT CONNECTIONS ARE TO BE RIGID AND LEAK FREE ASSEMBLIESAS MANUFACTURED BY DUCTMATE INDUSTRIES OR APPROVED EQUIVALENT.4. ALL BRANCHES AND TAKEOFFS SHALL BE EQUIPPED WITH MANUAL VOLUME CONTROLLING DEVICESHAVING AN INDICATING AND LOCKING DEVICE.5. SUPPORT HORIZONTAL DUCTS WITH HANGERS SECURED TO BAR JOISTS OR STRUCTURE ABOVE, ATINTERVALS NOT TO EXCEED 5'-0". DUCTWORK SHALL NOT BE SUPPORTED FROM ROOF DECKING, AND/ORBRIDGING, BUT SHALL BE SUSPENDED FROM THE STRUCTURE. DUCTWORK SHALL CLEAR ALL SPRINKLERSAND OTHER OBSTACLES AND SHALL BE HUNG AS HIGH AS POSSIBLE IN WORK AND STORAGE AREAS.6. ALL REGISTERS AND DIFFUSERS SHALL BE AS SCHEDULED ON DWG M200, FLUSH TO THE CEILING,WALLS, ETC., AND SHALL HAVE MANUFACTURERS BAKED ENAMEL FINISH (COLOR TO MATCH CEILINGTILES OR CEILING). REGISTERS MOUNTED ON EXPOSED DUCTWORK SHALL HAVE ANODIZED ALUMINUMFINISH. DIFFUSERS SHALL BE OF THE ADJUSTABLE PATTERN TYPE WITH VOLUME CONTROL DAMPERSAND FLOW EQUALIZING. ANY PART OF DIFFUSER HOUSING LOCATED IN CONCEALED CEILING MUST BEINSULATED, SEE DETAIL.7. FIBERGLASS DUCTWORK WILL NOT BE ALLOWED.8. MECHANICAL CONTRACTOR SHALL REFER TO DUCTWORK SCHEDULE FOR DUCTWORK TYPE, HANGERSYSTEM, CONNECTIONS, ETC. NOTIFY ARCHITECT IMMEDIATELY IF ANY DISCREPANCY WITH THEDRAWINGS.9. ALL DUCTWORK SHALL BE HUNG AS HIGH AS POSSIBLE TO MAINTAIN ARCHITECTURAL CEILING HEIGHTREQUIREMENTS.10. PROVIDE SPLITTER OR VOLUME DAMPERS ON ALL NEW SUPPLY AIR DUCT SPLITS AND TAPS AND AIREXTRACTORS ON ALL SUPPLY AIR REGISTERS.11. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL CEILING DIFFUSERS ANDREGISTERS.12. WHEN NEW DUCTWORK CONFLICTS WITH EXISTING DUCTWORK, PIPING, ETC., NEW DUCTWORK SHALLBE SET UP OR DOWN AS REQUIRED WITH GGB "THE SOURCE" PROJECT MANAGER'S PERMISSION.V. AUTOMATIC TEMPERATURE CONTROLGENERAL1. INSTRUCTION AND ADJUSTMENT UPON COMPLETION OF THE JOB, THE CONTRACTOR SHALLCOMPLETELY ADJUST AND MAKE READY FOR USE ALL THERMOSTATS, CONTROL VALVES, DAMPERMOTORS, AND RELAYS PROVIDED UNDER THIS CONTRACT. THE CONTRACTOR SHALL PROVIDE ACOMPLETE INSTRUCTION MANUAL COVERING THE FUNCTION AND OPERATION OF ALL CONTROLCOMPONENTS ON THE JOB. THE MANUAL SHALL BE FURNISHED TO THE OWNER'S OPERATINGPERSONNEL, AND A COMPETENT TECHNICIAN SHALL BE PROVIDED FOR INSTRUCTION PURPOSES. THECONTRACTOR SHALL FURNISH A FRAMED SCHEMATIC CONTROL DIAGRAM SEQUENCE OF OPERATIONAND WIRING DIAGRAM IN A LAMINATED COVER.2. SERVICE AND GUARANTEE CONTROLS SHALL BE ADJUSTED, REPAIRED OR REPLACED FREE OFCHARGE FOR A PERIOD OF ONE (1) YEAR, UNDER NORMAL USE AND SERVICE.3. THERMOSTATS A. MOUNT SENSORS 5'-0" ABOVE FINISHED FLOORS AND THERMOSTATS AT 4'-0" ABOVE FINISHED FLOOR OR AS NOTED ON PLANS. TURN OVER OPERATING INSTRUCTIONS TO TENANT REPRESENTATIVE.4. ALL LOW VOLTAGE WIRING FOR THERMOSTATS/SENSORS SHOULD BE NO LESS THAN 18 GAUGE.VI. SPECIFIC HVAC SPECIFICATIONSSEE HVAC DRAWINGS SPECIFICATIONS FOR:1. WORK FURNISHED AND/OR INSTALLED BY LANDLORD.2. INSULATION AND/OR ACOUSTIC LINING 1) DUCTWORK3. AUTOMATIC TEMPERATURE CONTROLS 1) DESCRIPTION OF OPERATIONS 2) OPERATING INSTRUCTIONS4. EQUIPMENT 1) EXHAUST FANS & HVAC UNITS. 2) MISCELLANEOUS HVAC EQUIPMENT ACCESSORIES.VII. INSULATION1. ALL UNEXPOSED SUPPLY AIR DUCTWORK WITHIN BUILDING SHALL HAVE 2", 1 POUND DENSITY (R-6.0MINIMUM INSTALLED) FIBERGLASS DUCT WRAP INSULATION WITH FOIL FACE VAPOR BARRIER, ADHEREDWITH WHITE MASTIC CEMENT AND FOIL TAPE.2. LEADING EDGES OF DUCT INSULATION SHALL BE OVERLAPPED BY ADJOINING INSULATION FOR 6"MINIMUM AND THEN SEALED WITH FOIL VAPOR BARRIER ADHESIVE TAPE AND COATED WITH WHITEMASTIC CEMENT SO THAT NO FIBERGLASS INSULATION IS VISIBLE. MECHANICAL CONTRACTOR SHALLREFER TO MANUFACTURER'S INSTALLATION MANUAL FOR ADDITIONAL REQUIREMENTS,RECOMMENDATIONS, PROCEDURES, ETC.3. ALL INSULATION ON EXISTING PIPING OR DUCTS THAT IS WETTED, DAMAGED, DISTURBED ORREMOVED SHALL BE REPLACED.4. MAXIMUM FLAME SPREAD SHALL BE 25 AND MAXIMUM SMOKE DEVELOPED CRITERIA SHALL BE 50 ORLESS TO MEET MORE STRINGENT LOCAL CODE CRITERIA.5. RETURN AIR DUCTWORK SHALL BE INTERNALLY LINED WITH 1" THICK, 3 PCF DENSITY, NEOPRENECOATED, LONG TEXTILE FIBER TYPE DUCT LINER, WITH COATING ON THE AIR STREAM SIDE CONFORMINGTO NFPA 90A. DUCT LINER ADHESIVE SHALL BE AS RECOMMENDED BY DUCT LINER MANUFACTURER,AND SHALL COMPLY WITH ASTM C-916. DUCT LINER FASTENERS SHALL COMPLY WITH SMACNA "HVACDUCT CONSTRUCTION STANDARDS", LATEST EDITION. THERMAL CONDUCTIVITY SHALL BE EQUAL TO ORLESS THAN 0.26 AT 75°F. DUCT DIMENSIONS INDICATED ARE NET INSIDE DIMENSIONS REQUIRED FORAIRFLOW. INCREASE DUCT SIZE TO ALLOW FOR INSULATION THICKNESS. DUCT LINER IS PERMITTED FORACOUSTICAL PURPOSES.MECHANICAL NOTES AND SPECIFICATIONSVIII. FLEXIBLE CONNECTIONSFINAL CONNECTIONS TO EXHAUST FAN(S) SHALL BE WITH A HEAVY AIRTIGHT ACID RESISTANT FIRERETARDANT FIBER GLASSED NEOPRENE CONNECTOR, A MINIMUM OF SIX (6) INCHES IN LENGTH. THECONNECTOR SHALL BE FASTENED TO EQUIPMENT AND DUCT WITH TWO FLEXIBLE REMOVABLE BRASSSTRAPS, OR ALTERNATE APPROVED METHOD.IX. FLEXIBLE DUCTFLEXIBLE DUCT FOR CONNECTIONS SHALL BE A FACTORY FABRICATED ASSEMBLY CONSISTING OF ANINNER SLEEVE, INSULATION AND AN OUTER FOIL (ALUMINIZED) MOISTURE BARRIER. THE INNER SLEEVESHALL BE CONSTRUCTED OF A CONTINUOUS VINYL COATED SPRING STEEL WIRE HELIX FUSED TO ACONTINUOUS LAYER OF FIBERGLASS IMPREGNATED AND COATED VINYL. A 1-1/4" THICK LAYER OFINSULATING BLANKET OF FIBERGLASS WOOL SHALL ENCASE THE INNER SLEEVE AND BE SHEATHEDWITH AN OUTER MOISTURE BARRIER OF A BIDIRECTIONAL REINFORCED METALIZED VAPOR BARRIER.THE FLEXIBLE DUCT SHALL BE RATED FOR A MAXIMUM WORKING VELOCITY OF 6000 FPM AND SHALL BELISTED BY THE UNDERWRITERS LABORATORIES UNDER THEIR UL-181 STANDARDS AS A CLASS 1 DUCTAND SHALL COMPLY WITH NFPA STANDARD - 90A. THE FLEXIBLE DUCT SHALL BE THERMAFLEX M-KC ORAPPROVED EQUIVALENT. FLEXIBLE DUCT SHALL ROUTE FROM SHEET METAL DUCTWORK TO CEILINGDIFFUSERS ONLY. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 6'-0" MAXIMUM. THERE SHALL BE NOEXPOSED FLEXIBLE DUCT. FLEXIBLE DUCT BENDS MUST NOT BE GREATER THAN 45° OVER A 3 FOOTSPAN. KINKS OR BUNCHING OF FLEXIBLE DUCT IS PROHIBITED.X. INDOOR AIR QUALITY1. NO ANALYSIS HAS BEEN MADE WITH REGARD TO SOURCES OR POTENTIAL SOURCES OF INDOOR OROUTDOOR AIR CONTAMINANTS OR LEVELS OF CONTAMINATION.2. IT IS THE RESPONSIBILITY OF THE GENERAL AND MECHANICAL CONTRACTOR TO INFORM THETENANT'S REPRESENTATIVE, LANDLORD AND TENANT'S ARCHITECT IF ANY SOURCE OR POTENTIALSOURCE OF INDOOR AIR CONTAMINATION IS IDENTIFIED.3. PRIOR TO ENCLOSING SPACES SUCH AS PLUMBING CHASES, AIR SHAFTS AND RETURN AIR PLENUMSCLEAN ALL AREAS THOROUGHLY. THE CONTRACTOR SHALL GUARANTEE THAT THE PLENUM CHAMBERUSED FOR RECIRCULATING OF AIR WILL BE OF TIGHT CONSTRUCTION AND THAT ALL SOURCES OFCONTAMINATION FROM TRAPS, SOIL STACKS, DOWNSPOUTS, VENTS, EXHAUST DISCHARGES AND OTHERSOURCES WILL BE ENCLOSED SO THAT NO CONTAMINATED AIR WILL BE RECIRCULATED.4. PRIOR TO COMMENCING CONSTRUCTION ACTIVITIES SHUT OFF THE HVAC SYSTEM, BLOCK OFF ALLAIR GRILLS, DIFFUSERS, AND OTHER OPENINGS OUTSIDE THE IMMEDIATE CONSTRUCTION AREA.OPENINGS TO ADJACENT TENANT SPACES SHALL BE COVERED WITH FILTER MEDIA TO PREVENT DUSTAND OTHER AIRBORNE CONTAMINANTS FROM PASSING TO ADJOINING SPACES.5. CONTRACTOR TO INSTALL TEMPORARY EXHAUST SYSTEM TO VENTILATE CONSTRUCTION SITE ANDKEEP SITE UNDER SLIGHT NEGATIVE PRESSURE DURING ALL HOURS OF CONSTRUCTION, EVEN IF AFTERNORMAL BUSINESS HOURS.6. CONTRACTOR TO INSTALL TEMPORARY BARRIERS TO PROTECT ADJACENT SPACES FROM DUST,PARTICULATES, VAPORS AND NOISE. WHERE TEMPORARY BARRIERS ARE INSTALLED ALWAYS MAINTAINFIRE EXITS AND EXITWAYS.Exp:_____________PRO F E S S OINAL MECHANICALKEVIN K.HERBERTE NGI NEER-STATEOFNEVADANo.15894 3-31-21