Loading...
Electrical Plans-420 E Deer Springs WayE100LIGHTING FIXTURESCHEDULE ANDELECTRICAL SYMBOLLEGENDTARSHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:112-22-2020 - PER CITY & CLIENTCOMMENTSARRNORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGS11-13-2020LANDLORD TENANT IMPROVEMENTSUITE 100P R O FESSIONAL E N GI NEER - STATE OF NEVADANo. 024316 CHARLES SPARSONSExpiresELECTRICAL12/31/21LIGHTING FIXTURE SCHEDULELight TypeDescriptionManufacturer & Product #Light SourcePowerSupplySystemWattsVoltageDimmingProtocolNotesD14" LED DOWNLIGHT WITH WHITE TRIM RINGAND CLEAR ALZAC REFLECTOR.EATONLD4B 30 D1010 EU4B 3040 80 35 4LB W 0L1Integral LEDBeam: 75°CCT: 3500°KCRI: 80+Lumens: 3,000Integral27.6120V0-10VD1EMSAME AS D1 EXCEPT WITH EMERGENCYBATTERY BACK UP.EATONLD4B 30 D1010 EU4B 3040 80 35 4LB W 0L1 EIEM14Integral LEDBeam: 75°CCT: 3500°KCRI: 80+Lumens: 3,000Integral27.6120V0-10VD24" LED DOWNLIGHT WITH WHITE TRIM RINGAND CLEAR ALZAC REFLECTOR.EATONLD4B 10 D1010 EU4B 1020 80 35 4LB W 0L1Integral LEDBeam: 75°CCT: 3500°KCRI: 80+Lumens: 1,000Integral11120V0-10VD2EMSAME AS D2 EXCEPT WITH EMERGENCYBATTERY BACK UP.EATONLD4B 10 D1010 EU4B 1020 80 35 4LB W 0L1 EIEM7Integral LEDBeam: 75°CCT: 3500°KCRI: 80+Lumens: 1,000Integral11120V0-10VD36" LED DOWNLIGHT WITH WHITE TRIM RINGAND CLEAR ALZAC REFLECTOR.EATONLD6B 10 D1020 EU4B 1020 80 35 4LB W 0L1Integral LEDBeam: 75°CCT: 3500°KCRI: 80+Lumens: 2,000Integral11120V0-10VD3EMSAME AS D3 EXCEPT WIRED TO REMOTEMICROINVERTER MOUNTED INSIDE BUILDINGIN CEILING SPACE AS SPECIFIED ON LIGHTINGPLAN.EATONLD4B 10 D1020 EU4B 1020 80 35 4LB W 0L1Integral LEDBeam: 75°CCT: 3500°KCRI: 80+Lumens: 2,000Integral11120V0-10VEM1Surface emergency lighting unit with integral batterypack, test switch, indicator light and 90 minutebattery. Aimable optics. Mounted on pendant facingdown similar to ceiling mounted configuration.Fixture to have self diagnostics and remote test.bottom to be level with adjacent lighting in the area.Black finish.LITHONIAELM2L B UVOLT SDRTLP220L 220lumen, 2.4 watt,linear pattern,two lampsIntegral2.4120VNon-DimEMHRecessed emergency lighting unit with integralbattery pack, test switch, indicator light and 90minute battery. Black finish.ConcealiteF5 LED45 90 BLACK(2) 3 watt LEDlightsIntegral6120VNon-DimEZCAdjustable Recessed or Surface Mount LEDEdge-Lit Exit Sign with Battery Back-Up, 120V,Ceiling Mount, White finish, Green lettersContech LightingDouble Face: REXA-DF-G-EM-C-P, wiredfor 120VSingle Face: REXA-SF-G-EM-P, wired for120V5 WATT LEDIntegral5120VNon-DimF1LED GENERAL LIGHTING LINEAR LUMINAIREWITH CURVED LENS.ORACLE LIGHTING4 OC1LED 4000L 010V MVOLT 35K 85USAIntegral LEDCRI: 85+Lumens: 4,000Integral27120V0-10VF1EMSAME AS F1 EXCEPT WITH INTEGRALEMERGENCY LIGHTING BATTERY, TESTSWITCH AND INDICATOR LIGHT.ORACLE LIGHTING4 OC1LED 4000L 010V MVOLT 35K 850EMGLED USAIntegral LEDCRI: 85+Lumens: 4,000Integral27120V0-10VP1LED STANDARD DOME SELF BALLASTEDDOME WITH HAMMERED COPPER EXTERIORFINISH AND WHITE INTERIOR FINISH.BOCK LIGHTING516B G21 G1 LED1 35K 010V 1SL 116ARG21 64250 G21Integral LEDLumens: 2,000Integral18120V0-10VP2LED DECORATIVE PENDANTROLL AND BLUFFBLUFF CITY 14 INCH / BLACK & WHITE6 Watt FrostedLumens: 480N/A6120VNonDimP3ELLIMINATEDTH1LED TRACK HEAD WITH WHITE FINISH, FULLYADJUSTABLE FOR DISPLAY LIGHTING.Solais Power SecureFixture: Xd24 40 35K 2400 WH JIntegral LEDBeam: 40°CCT: 3500°CRI: 85Lumens: 2,400Integral28120VMLV/ForwardPhaseT18' LONG, SINGLE CIRCUIT TRACK. SURFACEMOUNTED PER ARCHITECTURAL DETAILS.PROVIDE ADDITIONAL LIVE END FEEDS ASREQUIRED PER LIGHTING PLAN.ALL PARTS, MOUNTING PIECES, END FEEDS,AND CONNECTORS, TO BE COORDINATED BYSUPPLIER PRIOR TO PURCHASING. PROVIDECURRENT LIMITING END FEEDS FOR T SERIESTRACK SYSTEM BY JUNO WITH CURRENTLIMITING C/B AS NOTED ON LIGHTING PLAN.Juno LightingTrack: T8FTWH with current limiting endfeed.120VMLV/ForwardPhaseRefer to Architecturaldrawings for continuouslengths required.DATA CABLE OUTLET - MOUNTED AT 18" AFF UON. REFER TO DETAIL ON E101.ROUTE CAT6 CABLE TO I.T. RACK LOCATION.TELEPHONE CABLE OUTLET - MOUNTED AT 18" AFF UON. REFER TO DETAIL ONE101. ROUTE CAT6 CABLE TO TTB LOCATION.JUNCTION BOX - MOUNTING HEIGHT AND SIZE AS REQUIRED BY CODE OR ASNOTED ON DRAWINGSPANELBOARD (120/240V - 1 ph - 3W)JSYMBOLDUPLEX RECEPTACLE - 20 AMPERE, 125 VOLT - MOUNTED AT 18" AFF UON."WP" = FURNISH AND INSTALL WATERPROOF "WHILE IN USE" COVER."GFCI" = GROUND FAULT CIRCUIT INTERRUPTER TYPE."IG" = ISOLATED GROUND TYPE. ROUTE ADDITIONAL AND SEPARATE ISOLATEDGROUND IN BRANCH CIRCUIT. "SW" = SHOW WINDOW RECEPTACLE ABOVE WINDOW.DESCRIPTIONPCTTBTTCTYPUONWPCPLUMBING CONTRACTORTELEPHONE TERMINAL BOARDTELEPHONE TERMINAL CABINETTYPICALUNLESS OTHERWISE NOTEDWEATHERPROOFMOUNTED 8" ABOVE BACKSPLASH (TO CENTER OF BACKBOX)HOMERUN TO PANEL INDICATING CIRCUIT NUMBERS - ALL WIRING SHALL BE #12 WITHGROUND WIRE UON (INCREASE TO #10 FOR CIRCUITS BETWEEN 100 AND 200 LF)CONSULT ENGINEER FOR RUNS OVER 200 LIN FEET IF WIRE SIZE IS NOT INDICATED -ALL HOMERUNS SHALL BE TO A 20 AMPERE, 1 POLE CIRCUIT BREAKER UON. WIREFILL AS REQUIRED FOR APPLICATION INDICATED. (TIE) INDICATES HOMERUN ISINDICATED IN MULTIPLE LOCATIONS, TIED TOGETHER AT CIRCUIT BREAKER. STANDARD SWITCHES - 20 AMPERE, 120/277 VOLT, SINGLE POLE - MTD AT 48" AFFUON ("3" = THREE-WAY, "4" = FOUR-WAY)EXHAUST FAN - 120 VOLT, FRACTIONAL HORSEPOWER - FURNISHEDSINGLE OR THREE PHASE MOTOR - SEE DRAWINGS FOR DESCRIPTIONAND INSTALLED BY MC, WIRED BY ECEFMANUAL MOTOR STARTER - 120/240 VOLT - SURFACE MOUNTED AT 48" AFF UON.PROVIDE OVERLOADS PER MECHANICAL EQUIPMENT INSTALLATION REQUIREMENTSAND UNIT NAMEPLATE DATA.MDUPLEX RECEPTACLE - 20 AMPERE, 125 VOLT - MOUNTED FLUSH IN FLOOR.HUBBELL #BA2436 CAST IRON BOX, ALUM. COLLAR, SA3825 ALUM. COVER OREQUIVALENT. (FOR CONCRETE FLOOR)COMBINATION VOICE/DATA TELECOM OUTLET. REFER TO CIRCUITS FOR CAT 6TERMINATED CABLES BACK TO TELEPHONE BACKBOARD.HEAVY DUTY POWER DISCONNECT SWITCH, SIZED PER CIRCUIT, NON FUSED. NEMACONFIGURATION SHALL BE AS REQUIRED.DOUBLE DUPLEX RECEPTACLE - 20 AMPERE, 125 VOLT - MOUNTED AT 18" AFFUON.DOUBLE DUPLEX RECEPTACLE - 20 AMPERE, 125 VOLT - MOUNTED FLUSH INFLOOR. HUBBELL #3SFBC CAST IRON RECESSED 2-GANG BOX WITH (2) #3SFBRPDUPLEX RECEPT. KNOCKOUT FACEPLATES AND #3SFB-COLOR FLOORBOXCOVER. VERIFY COLOR WITH ARCHITECT PRIOR TO PROCUREMENT.RECEPTACLES TO BE INCLUDED FLOORBOX. (FOR CONRETE FLOOR)HEAVY DUTY POWER DISCONNECT SWITCH, SIZED PER CIRCUIT, FUSED ASINDICATED. NEMA CONFIGURATION SHALL BE AS REQUIRED. "WP" = WATERPROOF.50AFWPLA:5(TIE)FLOORWITH CAT 6 CABLES3/4" CONDUIT IN WALLSTRUCTURELAY-IN CEILINGFURNISH AND INSTALL ALLTELECOM WIRING IN CONDUIT.(TYPICAL)SCALE:NONECONDUIT ROUTING DETAILTYPICAL PHONE / DATAE1001CAT6 CABLING BY E.C. BACK TOEXISTING DATA RACK1 F1F1F1F1EZCEZCTH1TH1F1-EMF1-EMF1EZCF1-EMF1-EMF1F1F1-EMP1P1P1TH1D3D3D3D3D3D3D3D3-EMD3-EMD3D3D3-EMD3-EMEZCF1-EMEZCF1F1-EMF1D3-EMFEFEFET1-4'-0"TH1TH1T1-8'-0"TH1TH1TH1T1-10'-0"F1F1F1-EMF1-EMF1-EMF1F1EZCTH1TH1TH1TH1T1-16'-0"TH1TH1TH1TH1TH1TH1TH1D3D3TH1TH1TH1TH1TH1T1-4'-0"TH1TH1T1-4'-0"TH1TH1T1-4'-0"D3D3-EMFED3D3D3D3P2P2D3D3-EMD3D3D3D3-EMD1-EMD1D1-EMD1D1D1TH1T1-4'-0"TH1TH1T1-4'-0"TH1OSOSDOS1TYPICAL: DASHED LINESBETWEEN LIGHTING CONTROLDEVICES INDICATE CAT5 LOWVOLTAGE WIRING, ORSWITCHING INTENT IF CIRCUITIS WIRED TO LCP.OSDA:1115 AMPCURRENTLIMITER.ABLCPTELLERSMOBILE POSASSOC.ENTRANCE / DELIVERIESUNISEXTOILETROOMCASHROOMOFFICEELECTRICAL /DATA /SECURITYEQUIPMENTSECURESTORAGECHECK-IN /RECEPTIONRECEPTIONLOBBYSALESHALLWAYLOUNGEBUILDINGSPRINKLER ROOMN.I.C.BUILDINGELECTRICALROOMN.I.C.MAINENTRY /EXITEXTERIORPARKINGEXTERIOREXTERIORTR ALCOVE1MLV0-10VLVLVOS1OSD0-10VA:29R2OSDA:33R433A:29R23A:35R5, 15/1321111111111111111DAYLIGHT ZONE33 WATTS OF GENERALLIGHTING.CLEARANCE NOTE ABOVESHELVING: EC TO MAINTAIN18" CLEAR ABOVESHELVING. STORAGESHELVING IS 9'-0" HIGH.1SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:112-22-2020 - PER CITY & CLIENTCOMMENTSARRNORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGS11-13-2020LANDLORD TENANT IMPROVEMENTSUITE 100SCALE:1/4" = 1'-0"LIGHTING FLOOR PLANTRE200LIGHTING FLOORPLAN1.WIRE ALL EXIT SIGNS, NIGHT LIGHTS AND BATTERY PACKS TOLOCAL LIGHTING CIRCUITS AHEAD OF ALL LOCAL SWITCHINGAND LIGHTING CONTACTORS. PROVIDE ADDITIONALUN-SWITCHED HOT WIRE IN BRANCH CIRCUIT TO FACILITATEWIRING.2.COORDINATE LOCATIONS OF ALL LIGHTING FIXTURES ANDCEILING MOUNTED DEVICES WITH THE ARCHITECTURALREFLECTED CEILING PLANS.3.PER 2018 IECC: LIGHTING SYSTEMS TO BE TESTED TO ENSUREPROPER CALIBRATION, ADJUSTMENT, PROGRAMMING ANDOPERATION.WALL MOUNTED OCCUPANCY SENSOR, PASSIVE IR, WITH ON/OFF SWITCH. LIGHTS TO TURN OFFAFTER 30 MINUTES OF NO MOVEMENT IN ROOM. SENSOR SWITCH, WATT STOPPER ORENGINEER APPROVED EQUIVALENT.WALL MOUNTED OCCUPANCY SENSOR, PASSIVE IR, WITH 0-10VOLT DIMMING AND ON/OFFSWITCH. LIGHTS TO TURN OFF AFTER 30 MINUTES OF NO MOVEMENT IN ROOM. SENSORSWITCH, WATT STOPPER OR ENGINEER APPROVED EQUIVALENT.CEILING MOUNTED OCCUPANCY SENSOR, DUAL TECHNOLOGY WITH LOW VOLTAGE WALLSWITCH. PROVIDE POWER PACK AS REQUIRED. PROVIDE DIMMING 0-10V POWER PACKS IF LVDSWITCH IS INDICATED.MOUNTED ON PENDANT FROM JUNCTION BOX ATTACHED TO STRUCTURE. BOTTOM OF SENSORTO BE LEVEL WITH BOTTOM OF LIGHTING. SENSOR SWITCH, WATT STOPPER OR ENGINEERAPPROVED EQUIVALENT.LOW VOLTAGE SWITCH WITH 0-10 VOLT SLIDE DIMMER AND ON/OFF SWITCH TO PAIR WITH OCCSENSORS OR LIGHTING CONTROL PANEL DIMMING CIRCUIT IN SAME ROOM.LOW VOLTAGE ON/OFF SWITCH TO PAIR WITH OCC SENSORS IN SAME ROOM.LOCAL LINE VOLTAGE DIMMER SWITCH, NOVA T OR SIMILAR. DIMM TO OFF. ELV = ELECTRONICLOW VOLTAGE, 0-10 = 0-10 VOLT DIMMABLE, MLV = MAGNETIC LOW VOLTAGE. PROVIDECONTROL WIRING AS REQUIRED.EXIT SIGNS, NIGHT LIGHTS, EMERGENCY LIGHTING AND EMERGENCY BATTERY PACK IN FIXTUREINDICATED AS "EM" SHALL BE WIRED AHEAD OF ALL SWITCHING. FIXTURES WITH "EM" TO BEWIRED AS NORMALLY SWITCHED. COORDINATE WIRING WITH MANUFACTURERS INSTALLATIONINSTRUCTIONS TO ENSURE THAT BATTERY WILL OPERATE FIXTURE DURING A POWER OUTAGEFOR 90 MINUTES MINIMUM. PROVIDE UNSWITCHED WIRE IN HOMERUN AND IN BRANCH CIRCUITSAS REQUIRED TO FACILITATE CIRCUITING.LOCATION OF LOW VOLTAGE LIGHTING CONTROL PANEL OVERRIDE SWITCH. REFER TO LIGHTINGCONTROL PANEL WIRING DIAGRAM ON THIS DRAWING.WIRE THROUGH RELAY FOR ON/OFF OR DIMMING CONTROL AS INDICATED ON LIGHTING CONTROLDIAGRAM. REFER TO LIGHTING CONTROL PANEL WIRING DIAGRAM ON THIS DRAWING.APPROX. LOCATION OF EXTERIOR ILLUMINATED SIGNAGE POWER. EC SHALL COORDINATE EXACTLOCATION WITH SIGN VENDOR DRAWINGS PRIOR TO ROUGH IN AND VERIFY EXACT CONNECTIONREQUIREMENTS. EC SHALL PROVIDE A CONCEALED POWER DISCONNECT SNAP-SWITCH,WATERPROOF IN A LOCATION APPROVED BY GC, IF NOT INTEGRAL TO SIGN.OSOS1LVDLV1OSD23R3 - RELAYR4 - RELAYPANEL "A"R1 - RELAYR2 - RELAYLIGHTING CONTROL PANEL LCPACUITY "BLUE BOX LT" RELAYPANEL #GR1408 LT ENC SM NE1GR1408 LT INT DTC DVBRANCH CIRCUIT OUT TOLIGHTING IN TOILETS, ASSOC,RECEP. DESKBRANCH CIRCUIT OUT TO SALES AREA GENERALLIGHTING.BRANCH CIRCUIT OUT TOTRACK IN PERIMETER SALESAREAR5 - RELAYR6 - RELAYINTEGRAL DIGITAL ASTRONOMIC TIME CLOCK TOOPERATE RELAYS. VERIFY EXACT SCHEDULEPROGRAMING WITH OWNER.FURNISH AND INSTALL: ACUITY BRIGHTON LOW VOLTAGEOVERRIDE SWITCH TO PROVIDE 30 EXTRA MINUTES OF"ALL LIGHT ON" WHEN PRESSED.LOCATE AT DOOR LEADING OUT TO SALES FROM HALLWAY(SEE LIGHTING PLAN AND PLAN NOTE #2).PROVIDE NAMEPLATE TO READ:PRESS FOR 30 EXTRA MINUTES LIGHTS ON. AFTER NORMALSTORE HOURS.R - RELAYTOILET EXHAUST FANSR8 - RELAYEXTERIOR ILLUMINATED SIGNEXTERIOR ILLUMINATED SIGNA:42422928333524PANEL "B"119BRANCH CIRCUIT OUT TO PEDESTAL DISPLAYS.BRANCH CIRCUIT OUT TOWALL DISPLAY UNITS.CAT5 WITH RJ45CONNECTORS.P R O FESSIONAL E N GI NEER - STATE OF NEVADANo. 024316 CHARLES SPARSONSExpiresELECTRICAL12/31/21 SSSSSFEFEFEDEHUMIDIFIER SUSPENDEDFESSS S4DATACABINET4TELLERSMOBILE POSA:313A:513AIR SCRUBBER111111A: 7A: 6A: 8A: 1072"72"72"A: 9A: 11A: 13A: 15A: 2A: 4A: 172A: 12GFCI3GFCI44"EF1 17A: 19,2130/2CCCC8CCCA: 14A: 16A: 2248"48"48"48"A: 2310A: 28R3A:30 EF-3 B:1314ROOFTOP UNITRTU-2. 37 MCA,208V-3PH50AFWP7911B50/33#6, 1#10G,3/4"CWPGFCIB:15(TIE)WPGFCIB:15(TIE)ROOFTOP UNITRTU-1. 37 MCA,208V-3PH50AFWP135B50/33#6, 1#10G,3/4"CMAIN SERVICESWITCHBOARD'MSRE'.ABLCP611PANEL FEEDERS INCEILING SPACE.A: 18CGFCIA: 20CC2#10, 1#10G,1/2"CA:27R1ASSOC.ENTRANCE / DELIVERIESUNISEXTOILETROOMCASHROOMOFFICEELECTRICAL /DATA /SECURITYEQUIPMENTSECURESTORAGECHECK-IN /RECEPTIONRECEPTIONLOBBYSALESHALLWAYLOUNGEBUILDINGSPRINKLER ROOMN.I.C.BUILDINGELECTRICALROOMN.I.C.MAINENTRY /EXITEXTERIORPARKINGEXTERIOREXTERIORADJACENTTENANTTR ALCOVE48"48"A: 24R61010B:2RECEPTACLE FORDEHUMIDIFIER.84"CC4A:409177CLEARANCE NOTE ABOVESHELVING: EC TO MAINTAIN18" CLEAR ABOVESHELVING. STORAGESHELVING IS 9'-0" HIGH.1ABCDE616161616161616161216111111111117158A: 378881SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:112-22-2020 - PER CITY & CLIENTCOMMENTSARRNORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGS11-13-2020LANDLORD TENANT IMPROVEMENTSUITE 100SCALE:1/4"=1'-0"POWER & COMMUNICATIONS FLOOR PLANTRE300POWER ANDCOMMUNICATIONSFLOOR PLANPOWER PLAN GENERAL NOTES1.CONDUIT PENETRATIONS: ALL PENETRATIONS THROUGH FIRE RATED WALLS,FLOORS, CEILING OR SHAFTS SHALL BE SEALED TO MAINTAIN FIRE INTEGRITYOF STRUCTURE.2.SURFACE MOUNTED CONDUIT OR WIREMOLD: USE OF SURFACE CONDUIT ORWIREMOLD TYPE RACEWAY SHALL BE APPROVED BY AND COORDINATED WITH,THE ARCHITECT AND OWNER ON SITE PRIOR TO ROUGH-IN.3.OWNER FURNISHED EQUIPMENT: EXACT WIRING AND CONNECTIONREQUIREMENTS SHALL BE VERIFIED ON SITE WITH THE EQUIPMENT NAMEPLATEDATA. CONTRACTOR SHALL FURNISH THE PROPER NEMA RECEPTACLE,DISCONNECT REQUIREMENTS CONNECTIONS, AND CIRCUITING IN ACCORDANCEWITH THE EQUIPMENT SPECIFICATIONS.4.MECHANICAL EQUIPMENT: VERIFY THE EXACT LOCATION OF MECHANICALEQUIPMENT WITH MC ON SITE. EXACT ELECTRICAL REQUIREMENTS SHALL BEVERIFIED WITH MECHANICAL EQUIPMENT NAMEPLATE DATA. THE CONTRACTORSHALL MAKE APPROPRIATE ADJUSTMENTS TO WIRE AND FUSE SIZES INACCORDANCE WITH THE UNIT NAMEPLATE DATA. DISCONNECT SWITCHED FORALL MOTORS AND EQUIPMENT SHALL BE INSTALLED IN A READILY ACCESSIBLELOCATION AND SHALL HAVE PROPER WORKING SPACE AS REQUIRED IN N.E.C.5.GROUNDING: ALL BRANCH CIRCUITS AND FEEDERS SHALL CONTAIN ANINSULATED GROUNDING CONDUCTOR IN ACCORDANCE WITH THE N.E.C.6.PROVIDE: UTILIZATION OF THE PHRASE "PROVIDE" WITHIN THE CONTEXT OFTHESE DOCUMENTS SHALL EXPLICITLY REPRESENT "FURNISH AND INSTALL".7.COORDINATE LOCATIONS OF RECEPTACLES AND OTHER WALL MOUNTEDDEVICES WITH THE ARCHITECTURAL WALL ELEVATIONS AND FINISHES.POWER & COMMUNICATIONSPLAN KEY NOTES1CASHWRAP OUTLETS TO BE MOUNTED IN MILLWORK,COORDINATE ROUTING OF CABLES AND MOUNTING OFOUTLETS WITH MILLWORK CONTRACTOR PRIOR TOROUGH-IN. PROVIDE 3/4" C IN CABINETRY MILLWORK FORPOWER AND 3/4" C IN CABINETRY MILLWORK FORTELECOMMUNICATIONS TO NEAREST FULL HEIGHT WALL FORTRANSITION TO CEILING SPACE.LOCATION OF DATA EQUIPMENT RACK, SWITCHES, POWERSUPPLIES ETC. ELECTRICAL CONTRACTOR SHALL FURNISHAND INSTALL ALL I.T. EQUIPMENT PER I.T. VENDORSPECIFICATIONS. ALL CAT6 DATA CABLING/CONDUIT SHALLBE ROUTED BACK TO THIS CABINET BY THE E.C.ELECTRIC WATER COOLER. VERIFY EXACT MOUNTING OFRECEPTACLE WITH PC ON SITE PRIOR TO ROUGH IN.PLYWOOD BACKBOARD (TTB): 8'-0" HIGH X 3/4" THICK, FORTELEPHONE TERMINAL BLOCKS, SECURITY CONTROL PANEL.ALL 4 TRADES SHALL BE COORDINATED THROUGH THEGENERAL CONTRACTOR. NO ONE IS PERMITTED TO MOUNTEQUIPMENT ON THIS BOARD UNLESS APPROVED BY THEGENERAL CONTRACTOR.2" CONDUIT TO BE ROUTED TO EXISTING BUILDINGTELEPHONE SERVICE. TO BE USED FOR NEW DEMARK CABLEAS REQUIRED.SOUND SYSTEM MUSIC SERVER / AMPLIFIER / NETWORKPLAYER (60 WAYYS, 120V) ON SHELF. REFER TO A410, DETAIL"O". ALSO REFER TO VENDOR DRAWINGS FOR WIRINGREQUIREMENTS.ROUTE CIRCUIT THROUGH LIGHTING CONTROL PANEL FORON/OFF CONTROL THROUGH TIME CLOCK. REFER TOLIGHTING PLAN E200 FOR ADDITIONAL INFORMATION.PROVIDE POWER AND DATA FOR WALL MOUNTED VIDEO ORQUE MONITORS. VERIFY EXACT REQUIREMENTS WITHVENDOR DRAWINGS PRIOR TO ROUGH IN. REFER TO A400FOR ADDITIONAL INFORMATION.WATER HEATER MOUNTED ON SHELF ABOVE SINK- 3.0KW, 240VOLT-1PH. PROVIDE POWER DISCONNECT SWITCH.RE-CIRC PUMP (FRACT. HP., 120V) IN THIS LOCATION TO BEWIRED TO CIRCUIT 'E8-13.FLOOR MOUNTED QUAD RECEPTACLE. COORDINATE EXACTLOCATION WITH OWNER PRIOR TO ROUGH IN. PROVIDE 3/4" CIN FLOOR FOR POWER TO NEAREST FULL HEIGHT WALL FORTRANSITION TO CEILING SPACE. ALL CUTTING AND CORINGTO BE COORDINATED WITH GENERAL CONTRACTOR.ALARM AND SECURITY PANELS BY VENDORS.SOUND SYSTEM VOLUME CONTROL LOCATIONS - (5)SEPARATE ZONES. REFER TO VENDOR DRAWINGS.QUAD RECEPTACLE FOR MASTER-BILT GLASS DOORREFRIGERATOR- 6.8 AMPS, 120V.EXHAUST FAN SHALL BE INTERLOCKED WITH ROOFTOP UNITSUCH THAT FAN IS OPERATING WHEN THE ROOFTOP UNIT ISIN AN OCCUPIED MODE. PROVIDE RELAY TO ACCOMPLISHCONTROL.FURNISH AND INSTALL 120 VOLT POWER TO MOTORIZEDSECURITY COUNTER GATE. COORDINATE EXACT WIRINGREQUIREMENTS WITH DOOR HARDWARE MANUFACTURERPRIOR TO ROUGH IN. 120 VOLT CIRCUIT SHALL BE 'E7-17'.CONTROLLED BY UP/DOWN SWITCH FURNISHED WITH GATE.SOUND SYSTEM SPEAKER LOCATION. SPEAKERS TO BEWIRED IN 5 SEPARATE ZONES BACK TO VOLUME CONTROLSTATION LOCATED IN OFFICE. SPEAKER WIRING TO BE INCONDUIT (FOR BIDDING PURPOSES 1/2" EMT. REFER TOVENDOR DRAWINGS FOR EXACT REQUIREMENTS.WIRE EXHAUST FAN THROUGH THE LIGHTING CONTROLPANEL FOR ON/OFF CONTROL ONLY.FAN SHALL RUN DURINGNORMAL STORE HOURS AND SHUT OFF AFTER HOURS.23456781011129SECURITYTELEPHONE#4A:32A:34SCALE:NONE54TTB - PHONE BOARDMOUNTING DETAIL13A:3614151617PROVIDE GROUND BARFOR USE BY VENDORS ASREQUIRED. 18" AFFDATAA:38DATADATARACKP R O FESSIONAL E N GI NEER - STATE OF NEVADANo. 024316 CHARLES SPARSONSExpiresELECTRICAL12/31/211111.SOUND SYSTEMa.ELECTRICAL CONTRACTOR SHALL PROVIDE ANY AND ALL PERMITS RELATED TO THE INSTALLATION OF THESOUND SYSTEM.b.ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL BACKBOXES, TRIM RINGS, CONDUITS ANDBUSHINGS FOR SOUND SYSTEM.c.ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE AND USABLE CONDUIT RACEWAY WITH WIRE PULLSTRINGS COMPLETE FROM EACH DEVICE TO SOUND SYSTEM RACK LOCATION.d.FURNISHING OF ALL SOUND SYSTEM DEVICES/ COMPONENTS (WIRE, SPEAKERS, AMPLIFIERS, VOLUMECONTROLS ) SHALL BE BY THE SOUND SYSTEM VENDOR.e.INSTALLATION OF ALL SOUND SYSTEM DEVICES/ COMPONENTS (WIRE, SPEAKERS, AMPLIFIERS, VOLUMECONTROLS ) SHALL BE BY THE ELECTRICAL CONTRACTOR.f.REFER TO SOUND SYSTEM VENDOR DRAWINGS AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OFDEVICES. ANY DEVICE PLACEMENT NOT SPECIFICALLY SPECIFIED IN THE VENDOR DRAWINGS ORARCHITECTURAL DRAWINGS WILL BE COORDINATED IN THE FIELD WITH THE PROJECT CONSTRUCTIONMANAGER AND/ OR ARCHITECT.2.IT/ TELECOM/ DATAa.TELECOM/DATA VENDOR WILL PROVIDE ANY AND ALL PERMITS RELATED TO THE INSTALLATION OF THETELECOM/ DATA SYSTEM.b.ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL BACKBOXES, TRIM RINGS, CONDUITS ANDBUSHINGS FOR TELECOM/ DATA SYSTEMS.c.ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE AND USABLE CONDUIT RACEWAY WITH WIRE PULLSTRINGS COMPLETE FROM EACH DEVICE TO THE DATA RACK AND/ OR PHONE BACKBOARD.d.TELECOM/DATA VENDOR WILL USE ELECTRICAL CONTRACTOR PROVIDED CONDUIT & PULL STRINGS TOINSTALL VENDOR PROVIDED WIRING TO ALL TELECOM/DATA DEVICES, RACKS, AND DEVICES.e.ALL TELECOM/ DATA TERMINATIONS/ PUNCH DOWNS TO BE BY THE TELECOM/ DATA VENDOR.f.FURNISHING & INSTALLATION OF ALL TELECOM/DATA DEVICES SHALL BE BY THE TELECOM/ DATA SYSTEMVENDOR.g.REFER TO TELECOM/DATA VENDOR DRAWINGS AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONSOF DEVICES. ANY DEVICE PLACEMENT NOT SPECIFICALLY SPECIFIED IN THE VENDOR DRAWINGS ORARCHITECTURAL DRAWINGS WILL BE COORDINATED IN THE FIELD WITH THE PROJECT CONSTRUCTIONMANAGER AND/ OR ARCHITECTh.GENERAL CONTRACTOR SHALL HAVE A SITE COORDINATION MEETING WITH SECURITY VENDOR PRIOR TOANY ROUGH-IN OR WIRE INSTALLATION.TELECOM/ DATA, & SOUND SYSTEMNOTES11 FE FE FE FESOUNDSYSTEMES ES ES ES ES ES ES DB ES CR CR CR CR CR CR CR CR KP IC IC IC IC ICIC IC MD PA IC IC IC IC PA PA PAMD MD PA PA PA IC IC IC IC IC IC MD KP IC IC IC ES CR EC EC EC EC EC IC IC IC 4X4 BOX- NETWORK DOOR CONTROLLER INSIDE SECURE SIDEUNSECURE SIDE 1 2" CONDUIT W/ CAT 6 TO POE SWITCH CEILING LINE CABLE A EXIT REQUEST PIR CABLE E CABLE F CABLE C,F 4X4 BOX ELECTRONIC STRIKE CARD READER SHEET TITLE : SHEET NO. : REVISION : ISSUE / DATE: CONSULTANT : DRAWN BY: 1 12-22-2020 - PER CITY & CLIENT COMMENTS ARR NORTH LAS VEGAS, NV 89084 420 EAST DEER SPRINGS WAY ISSUE 1 - BID - PERMIT DRAWINGS 11-13-2020 LANDLORD TENANT IMPROVEMENT SUITE 100 E400 SECURITY FLOOR PLAN TR/ ARR SCALE:1/4"=1'-0" SECURITY FLOOR PLAN NETWORK DATA RACK SECURITY LEGEND INTERNAL CAMERA EXTERNAL CAMERA CR CARD READER KP ALARM KEYPAD PANIC ALARM MOTION DETECTOR VM SECURITY VIEWING MONITOR IC EC GB GLASS BREAK SENSOR ELECTRONIC STRIKE *** DEADBOLT LOCK- NIGHT PA ES DB MD ***NOTE: ALL DOORS EQUIPPED WITH CARD READERS & ELECTRIC STRIKES TO RECEIVE A DOOR CONTACTOR & REQUEST TO EXIT DETECTOR. SCALE:3/8"=1'-0"E400 DOOR DETAIL- CARD IN/ MOTION OUT/ STRIKE1 PROFESSIONAL EN G INEER - STAT E OF NEVADANo. 0243 1 6 CHARLES S PARSONS Expires ELECTRICAL 12/31/21 1. ACCESS CONTROLS / CCTV/ INTRUSION DETECTION a.SECURITY VENDOR WILL PROVIDE ANY AND ALL PERMITS RELATED TO THE INSTALLATION OF THE SECURITY SYSTEM. b.ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL BACKBOXES, TRIM RINGS, CONDUITS AND BUSHINGS FOR SECURITY SYSTEMS: ACCESS CONTROL, INTRUSION DETECTION AND CAMERA SYSTEMS. c.ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE AND USABLE CONDUIT RACEWAY WITH WIRE PULL STRINGS COMPLETE FROM EACH DEVICE TO SECURITY CONTROL PANEL(S) AND/ OR NETWORK RACK. d.ALL SECURITY SYSTEM TERMINATIONS/ PUNCH DOWNS TO BE BY THE SECURITY VENDOR. e.SECURITY VENDOR WILL USE ELECTRICAL CONTRACTOR PROVIDED CONDUIT & PULL STRINGS TO INSTALL VENDOR PROVIDED WIRING TO ALL SECURITY SYSTEM DEVICES, RACKS, AND DEVICES. f.ALL SECURITY SYSTEM TERMINATIONS/ PUNCH DOWNS TO BE BY THE SECURITY VENDOR. g.FURNISHING & INSTALLATION OF ALL SECURITY DEVICES (ACCESS CONTROL, INTRUSION DETECTION & SECURITY CAMERAS SHALL BE BY THE RESPECTIVE SECURITY SYSTEM VENDOR. h.REFER TO SECURITY SYSTEM VENDOR DRAWINGS AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF DEVICES. ANY DEVICE PLACEMENT NOT SPECIFICALLY SPECIFIED IN THE VENDOR DRAWINGS OR ARCHITECTURAL DRAWINGS WILL BE COORDINATED IN THE FIELD WITH THE PROJECT CONSTRUCTION MANAGER AND/ OR ARCHITECT. i.GENERAL CONTRACT SHALL HAVE A SITE COORDINATION MEETING WITH SECURITY VENDOR PRIOR TO ANY ROUGH-IN OR WIRE INSTALLATION. SECURITY SYSTEMS NOTES 1 SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:112-22-2020 - PER CITY & CLIENTCOMMENTSARRNORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGS11-13-2020LANDLORD TENANT IMPROVEMENTSUITE 100TRSHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:112-22-2020 - PER CITY & CLIENTCOMMENTSARRNORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGS11-13-2020LANDLORD TENANT IMPROVEMENTSUITE 100E500POWER RISERMM1,200AMCBEXISTING METER CENTER -1,200A120/208V-3 PHASE, 4 WIRE100K AICM600/3MMMMALL PULL-OUTS ARERATED FOR 200AMPS/3PSERVICE FROMEXISTING PADMOUNTED UTILITYTRANSFORMER SHALLREMAIN.NEW PANEL "A"FURNISHED ANDINSTALLED BYTENANTCONTRACTOR.MLONEW PANEL "B"FURNISHED ANDINSTALLED BYTENANTCONTRACTOR.MLONEW LIGHTINGCONTROL PANELFURNISHED ANDINSTALLED BYTENANTCONTRACTOR.4#3/0, 1#6G, 2"CPANEL NAME: ALOAD SUMMARYPHASE BREAKDOWNNOTESMOUNTING:SURFACELOADKWCD.F.KWDAMPSTOTAL PANELGFCI = PROVIDE GROUND FAULT CIRCUITVOLTAGE:208Y/120V-3ph-4WLTG2.41.253.0KWC PHASE A:7.0BREAKER = 5ma FOR PERSONAL PROTECTIONBUS RATING:225AREC9.0N.E.C.9.0KWC PHASE B:7.1R = CIRCUIT ROUTED THROUGH LCP RELAYMAIN:MAIN LUGS ONLYAC0.01.000.0KWC PHASE C:7.9PANEL. REER TO WIRING DIAGRAM.A.I.C.42K AICHTG0.01.000.0LO = PROVIDE LOCK ON C/B CLIPETR OR NEW:NEWW. HTR.3.01.253.8PANEL NOTES:MISC.7.61.007.6TRACK LTG1.51.251.9CURRENT LIMITERSPER NEC article 220.43.Branch CCT watts have been subtracted.SHOW WIND.0.01.250.0N/ATOTAL23.525.370.20CCTNOTESDESCRIPTIONLTGRECACHTGW.HTR.MISCC/BPHASEC/BDESCRIPTIONLTGRECACHTGW.HTR.MISCNOTESCCT1ROOMS ON OCC SENSORS0.6320/1A20/1ATM MACHINE 10.3623MASTER-BILT REFRIGERATOR0.8220/1B20/1ATM MACHINE 20.3645MASTER-BILT REFRIGERATOR0.8220/1C20/1PURCHASING RECS0.7267AIR SCRUBBER0.6120/1A20/1CASH RECS0.7289QUE MONITORS0.5020/1B20/1CASHROOM QUAD RECEPT.0.181011TELLER POS STATIONS0.3620/1C20/1ELECTRIC WATER COOLER0.90GFCI1213TELLER POS STATIONS0.7220/1A20/1COUNTER OUTLETS AT DISPENSERY0.541415TELLER POS STATIONS0.7220/1B20/1BREAK ROOM - REFRIGERATOR0.401617MOBILE ACCESS POINT POS0.5420/1C20/1BREAK ROOM - COUNTER1.201819WATER HEATER1.5030/2A20/1BOH CONV. RECS0.7220211.50B20/1CHECK IN RECEPT0.722223TOILET REC0.1820/1C20/1WALL DISPLAYS1.08R62425SPARE20/1A20/1SPARE2627R1TOILET ROOM EXHAUST FAN0.2020/1B20/1PEDESTAL DISPLAYS0.36R32829R2TELLERS, CASHWRAP, HALLWAY0.6720/1C20/1MOTORIZED SECURITY GATE AT CTR0.10LO3031SPARE20/1A20/1TELEPHONE BOARD0.363233R4SALES AREA GENERAL LIGHTING0.2520/1B20/1TELEPHONE BOARD0.363435R5TRACK IN SALES AREA0.8615/1C20/1TTB DATA 10.363637QUE MONITORS0.5020/1A20/1TTB DATA 20.363839SPARE20/1B20/1BOH CONV. RECS0.724041SPARE20/1C20/1LIGHTING CONTROLL PANEL0.10LO42TOTALS:2.412.520.000.003.003.440.006.480.000.000.004.14TOTALS:PANEL NAME: BLOAD SUMMARYPHASE BREAKDOWNNOTESMOUNTING:SURFACELOADKWCD.F.KWDAMPSTOTAL PANELR = CIRCUIT ROUTED THROUGH LCP RELAYVOLTAGE:208Y/120V-3ph-4WLTG2.41.253.0KWC PHASE A:10.9PANEL. REER TO WIRING DIAGRAM.BUS RATING:225AREC0.4N.E.C.0.4KWC PHASE B:9.3LO = PROVIDE LOCK ON C/B CLIPMAIN:MAIN LUGS ONLYAC26.71.0026.7KWC PHASE C:10.1A.I.C.42K AICHTG0.01.000.0ETR OR NEW:NEWW. HTR.0.01.250.0PANEL NOTES:MISC.0.91.000.9TRACK LTG0.01.250.0N/APER NEC article 220.43.Branch CCT watts have been subtracted.SHOW WIND.0.01.250.0N/ATOTAL30.431.085.99CCTNOTESDESCRIPTIONLTGRECACHTGW.HTR.MISCC/BPHASEC/BDESCRIPTIONLTGRECACHTGW.HTR.MISCNOTESCCT1ROOFTOP UNIT RTU-14.4450/3A20/1DEHUMIDIFIER0.76234.44B20/1DUCT SMOKE DETECTORS0.10LO454.44C20/1SPARE67ROOFTOP UNIT RTU-24.4450/3A20/1SPARE894.44B20/1SPARE10114.44C20/1SPARE1213EF-30.1020/1A20/1SPARE1415ROOFTOP RECEPTACLES0.3620/1B20/1SPARE1617R7EXTERNAL SIGN1.2020/1C20/1SPARE1819R8EXTERNAL SIGN1.2020/1A20/1SPARE2021SPARE20/1B20/1SPARE2223SPARE20/1C20/1SPARE2425SPACEASPACE2627SPACEBSPACE2829SPACECSPACE3031SPACEASPACE3233SPACEBSPACE3435SPACECSPACE3637SPACEASPACE3839SPACEBSPACE4041SPACECSPACE42TOTALS:2.400.3626.740.000.000.000.000.000.000.000.000.86TOTALS:COMBINED LOAD SUMMARYConnected Load - Continuous KVALighting per NEC 220-127.73KVAWater Heater if NEC 422.13 applies3.00KVAAdditional for Track at 150va per 2 feet1.54KVACurrent liniting breakers used.Additional for Show window at 200W/Lin. Ft.N/A32.02KVADesigned branch circuits are subtractedContinuous load =44.29KVAConnected Load - Non-continuous KWRecept9.36KVAMisc.8.44KVAHVAC26.74KVANon-continuous load =44.54KVA125% Continuous + 100% Non-continuousContinuous load =1.25 x44.29=55.36KVANon-continuous load =1.00 x44.54=44.54KVAMin. Service Size=99.90KVA99.90KVA=277.50A208 x sq. root of 3Minimum Electric Service Size =277.50AP R O FESSIONAL E N GI NEER - STATE OF NEVADANo. 024316 CHARLES SPARSONSExpiresELECTRICAL12/31/211 SHEET TITLE :SHEET NO. :REVISION :ISSUE / DATE:CONSULTANT :DRAWN BY:NORTH LAS VEGAS, NV 89084420 EAST DEER SPRINGS WAYISSUE 1 - BID - PERMIT DRAWINGS11-13-2020LANDLORD TENANT IMPROVEMENTSUITE 100TRE600ELECTRICALSPECIFICATIONSSECTION 16010 - ELECTRICAL GENERAL PROVISIONS1.THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARYCONDITIONS, ALTERNATES, ADDENDAS AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. ELECTRICAL,ARCHITECTURAL, MECHANICAL AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THEDIVISIONS ARE A PART OF THE CONTRACT DOCUMENTS. ALL REVISIONS TO THE DRAWINGS ANDSPECIFICATIONS UP TO THE BID DUE DATE ARE A BINDING PART OF THE CONTRACT.2.VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH THE CONDITIONS AFFECTING THE INSTALLATION.SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF SUCH CONDITIONS AND NO ADDITIONALCOMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OFIGNORANCE OF THESE CONDITIONS.3.DISCREPANCIES BETWEEN ELECTRICAL, MECHANICAL AND ARCHITECTURAL, CONTRACT DRAWINGS, ORSPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER PRIOR TO FINAL BID SUBMITTAL.4.DEFINITIONS:A.)"CONTRACTOR" AS USED WITHIN THE CONTEXT OF THE ELECTRICAL CONTRACT DOCUMENTS SHALLEXPLICITLY REFER TO THE "ELECTRICAL CONTRACTOR".B.)THE TERM "FURNISH" SHALL MEAN TO SUPPLY AND DELIVER TO THE PROJECT SITE, READY FORUNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS.C.)THE TERM "INSTALL" SHALL MEAN WORK WHICH INCLUDES THE ACTUAL UNLOADING, UNPACKING,ASSEMBLY, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING,PROTECTING, CLEANING, AND SIMILAR OPERATIONS.D.)THE TERM "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL, COMPLETE AND READY FOR THEINTENDED USE.5.INCLUDE ALL LABOR, MATERIAL, EQUIPMENT, SERVICES AND PERMITS NECESSARY FOR THE PROPERCOMPLETION OF ALL ELECTRICAL WORK SHOWN. ITEMS OMITTED, BUT NECESSARY, TO MAKE THEELECTRICAL SYSTEM COMPLETE AND WORKABLE SHALL BE UNDERSTOOD TO FORM PART OF THE WORK.CONTRACTOR'S BID IS ASSUMED TO INCLUDE ANY PREMIUM TIME COSTS REQUIRED TO COMPLETE WORK.6.IT IS THE PURPOSE OF THE ELECTRICAL DRAWINGS TO INDICATE THE APPROXIMATE LOCATION OF ALLEQUIPMENT, OUTLETS, ETC. ASCERTAIN EXACT LOCATIONS AND ARRANGE WORK ACCORDINGLY. THERIGHT IS RESERVED TO EFFECT REASONABLE CHANGES IN THE LOCATION OF OUTLETS UP TO THE TIME OFROUGHING-IN, WITHOUT ADDITIONAL COST TO THE OWNER.7.TEMPERATURE AND INTERLOCK CONTROLS ARE PROVIDED AND WIRED BY A CONTROLS CONTRACTOR.LINE (120 VOLT) VOLTAGE CONTROL DEVICES, SUCH AS THERMOSTATS AND AQUASTATS, WHICH CONTROLFRACTIONAL HORSEPOWER, 120 VOLT MOTORS ARE FURNISHED BY MECHANICAL CONTRACTOR, AND AREMOUNTED AND WIRED BY THE ELECTRICAL CONTRACTOR.8.SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED FOR THE ELECTRICAL WORK.9.WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF LOCAL AND STATE(OBC - OHIO BUILDING CODE) CODES, AS WELL AS THE NATIONAL ELECTRICAL CODE (NEC), ASINTERPRETED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ). NO EXTRA COMPENSATION WILL BEALLOWED FOR ANY CHANGES NECESSARY FOR CODE COMPLIANCE. CONTRACTOR SHALL FOLLOW NECASTANDARDS OF INSTALLATION AS A MINIMUM.10.CONSULT THE DRAWINGS, PRODUCT DATA AND SHOP DRAWINGS COVERING THE WORK FOR VARIOUSOTHER TRADES, THE FIELD LAYOUTS OF THE CONTRACTORS FOR THE TRADE AND MAKE ADJUSTMENTSACCORDINGLY IN LAYING OUT THE ELECTRICAL WORK. WHERE ELECTRICAL REQUIREMENTS FOR OTHERTRADES VARIES FROM WHAT IS INDICATED ON THE DRAWINGS THE CONTRACTOR SHALL NOTIFY THEARCHITECT AND ENGINEER IMMEDIATELY AND SUSPEND ALL WORK ASSOCIATED WITH THE VARIATIONUNTIL A DETERMINATION IS MADE BY THE ARCHITECT AND ENGINEER.11.CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP AND MATERIALS, AND THE SUCCESSFULOPERATION OF ALL EQUIPMENT AND APPARATUS INSTALLED BY HIM FOR A PERIOD OF ONE YEAR AFTERFINAL ACCEPTANCE OF THE ENTIRE WORK BY THE OWNER, AND SHALL GUARANTEE TO REPAIR ORREPLACE AT HIS OWN EXPENSE ANY PART OF THE APPARATUS WHICH MAY SHOW TO BE DEFECTIVEDURING THAT TIME PROVIDED SUCH DEFECT IS, IN THE OPINION OF THE OWNER, DUE TO IMPERFECTMATERIAL OR WORKMANSHIP AND NOT TO CARELESSNESS OR IMPROPER USE.12.AUTHORIZED REPRESENTATIVES OF THE OWNER SHALL HAVE ACCESS TO AND PRIVILEGE OFINSPECTING ALL WORK AND MATERIALS AS WORK PROGRESSES. THESE REPRESENTATIVES SHALL HAVEAUTHORITY TO APPROVE OR REJECT WORK OR MATERIALS, USING DRAWINGS, SPECIFICATIONS, CODESAND GOOD ENGINEERING PRACTICES AS THE BASIS FOR APPROVAL OR REJECTION.13.THE EXISTING ELECTRICAL AND TELEPHONE SERVICE, AND ALL EXISTING COMMUNICATION SYSTEMSWITHIN THE BUILDING SHALL BE MAINTAINED THROUGHOUT THE CONSTRUCTION PERIOD. ANY SERVICESHUTDOWNS THAT MAY BE REQUIRED SHALL BE SCHEDULED THROUGH THE OWNER AND SHALL BE DONEAT A TIME AS DIRECTED BY THE OWNER. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED FOR THESESHUTDOWN PERIODS EVEN THOUGH PREMIUM-TIME WORK MAY BE REQUIRED. PROVIDE TEMPORARYSERVICE TO EQUIPMENT OR SYSTEMS THAT CANNOT BE SHUTDOWN, AS DETERMINED BY OWNER.14.PROVIDE A MINIMUM OF ONE WEEK'S NOTICE TO THE OWNER BEFORE ANY SERVICE SHUTDOWN ISSCHEDULED.15.BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVE EQUALS. THEDRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY TYPE, MODEL AND SIZE ANDTHUS ESTABLISH MINIMUM QUALITIES WHICH SUBSTITUTES MUST MEET TO QUALIFY FOR REVIEW. WHEREONLY ONE MAKE IS NAMED, IT SHALL BE PROVIDED. VERBAL REQUESTS OR APPROVALS SHALL NOT BEBINDING ON THE ARCHITECT, ENGINEER OR OWNER. SHOULD THE CONTRACTOR PROPOSE TO FURNISHMATERIALS AND EQUIPMENT OTHER THAN THOSE SPECIFIED, HE SHALL SUBMIT A WRITTEN REQUEST FORSUBSTITUTIONS TO THE ARCHITECT AT THE BID OPENING. INDICATE ANY ADDITIONS OR DEDUCTIONS TOTHE CONTRACT PRICE ON THE BID FORM.16.EQUIPMENT AND MATERIALS USED ON THIS PROJECT SHALL BE NEW AND UL. LISTED AND LABELEDFOR THE APPLICATION.17.PREPARE PDF SHOP DRAWINGS AND PRODUCT DATA FOR ALL SPECIFIED ELECTRICAL SYSTEMS ANDCOMPONENTS. THE SUBMITTALS WILL BE REVIEWED ONLY FOR GENERAL COMPLIANCE AND NOT FORDIMENSIONS, QUANTITIES, ETC. THE SUBMITTALS THAT ARE RETURNED SHALL BE USED FORPROCUREMENT. THE RESPONSIBILITY OF CORRECT PROCUREMENT REMAINS SOLELY WITH THECONTRACTOR.18.THE SUBMITTAL REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR ERRORS OROMISSIONS AND DEVIATIONS FROM THE CONTRACT REQUIREMENTS. IF THE SUBMITTAL SHOWSVARIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS FOR ANY REASON, THECONTRACTOR SHALL MAKE MENTION OF SUCH VARIATION IN HIS LETTER OF TRANSMITTAL. THECONTRACTOR SHALL NOTE IN RED ON THE SUBMITTAL ANY CHANGE IN DESIGN OR DIMENSION ON THEITEMS SUBMITTED INCLUDING CHANGES MADE BY THE MANUFACTURER WHICH MAY DIFFER FROM CATALOGINFORMATION. WHERE CONTENTS OF SUBMITTAL LITERATURE INCLUDE DATA NOT PERTINENT TO THESUBMITTAL, CLEARLY INDICATE WHICH PORTION OF CONTENT IS BEING SUBMITTED FOR REVIEW. WHEREADDITIONAL INSTALLATION DRAWINGS, WIRING DIAGRAMS OR OTHER DRAWINGS ARE SPECIFIED AS A PARTOF THE SUBMITTAL, THEY SHALL BE SUBMITTED AT THE SAME TIME WITH SHOP DRAWINGS AND PRODUCTDATA. PARTIAL SUBMITTALS AND SUBMITTALS NOT STAMPED WITH CONTRACTOR APPROVAL ARE NOTACCEPTABLE, AND WILL BE RETURNED FOR REPROCESSING.19.THE CONTRACTOR SHALL KEEP ONE COMPLETE SET OF THE CONTRACT WORKING DRAWINGS ON THEPROJECT SITE ON WHICH HE SHALL RECORD ANY DEVIATIONS OR CHANGES FROM SUCH CONTRACTDRAWINGS MADE DURING CONSTRUCTION. AFTER THE PROJECT IS COMPLETED, RECORD SETS OFDRAWINGS SHALL BE DELIVERED TO THE ARCHITECT IN GOOD CONDITION, AS A PERMANENT RECORD OFTHE INSTALLATION AS CONSTRUCTED.20.PROVIDE NAMEPLATES ON PANELBOARDS, DISTRIBUTION EQUIPMENT, SAFETY SWITCHES, MOTORSTARTERS AND CONTROL DEVICES. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, LETTERING SHALLINCLUDE THE NAME OR DESIGNATION OF EQUIPMENT, HORSEPOWER, VOLTAGE RATING AND SERVICEDESIGNATION. NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH A BLACK SURFACE AND WHITE CORE.IDENTIFICATION WITH A DYMO TYPE INSTRUMENT IS NOT PERMISSIBLE. THE INSIDE COVER OF ALLRECEPTACLE OUTLET PLATES SHALL BE PERMANENTLY MARKED TO INDICATE THE PANEL AND CIRCUITNUMBER OF THE OUTLET. THE INSIDE COVER OF ALL BLANK PLATES FOR JUNCTION BOXES INSTALLEDSHALL BE PERMANENTLY MARKED TO INDICATE THE SYSTEM. IDENTIFICATION OF BRANCH CIRCUITS SHALLBE TYPEWRITTEN ON DIRECTORY CARDS FURNISHED WITH ALL PANELS AND PLACED IN THE CARD HOLDERON THE DOOR. PROVIDE NEW TYPEWRITTEN DIRECTORY CARDS WITH UPDATED SCHEDULES FOR ALLEXISTING PANELS WITH NEW OR MODIFIED CIRCUITS.21.AFTER INSTALLATION, TEST FOR GROUNDS, SHORT CIRCUITS AND PROPER FUNCTION OF EACHSYSTEM AND RELATED WIRING. FAULTS IN THE INSTALLATION SHALL BE CORRECTED.22.INSULATION RESISTANCE TESTS SHALL BE MADE ON THE ELECTRICAL SYSTEM WITH AN APPROVEDMEGOHMMETER. PROVIDE ADDITIONAL GROUNDING COMPONENTS (ROD, ACTIVE ELECTRODE, ETC.) ASREQUIRED TO ACHIEVE 5 OHM RESISTANCE MAXIMUM FOR THE MAIN SERVICE DISCONNECT GROUNDINGELECTRODE SYSTEM.23.A GROUND CONTINUITY TEST SHALL BE MADE ON THE GROUNDING SYSTEM SHOWN TO BE INSTALLEDON THE DRAWINGS. WHERE AN EXISTING SERVICE OR PANELS ARE BEING REUSED, CONTRACTOR SHALLVERIFY PROPER GROUNDING OF SERVICE, PANELS, AND SEPARATELY DERIVED SYSTEMS AND CORRECTANY DEFICIENCIES IN THE GROUNDING ELECTRODE SYSTEM AND EQUIPMENT GROUNDING IN ORDER TOCOMPLY WITH THE NEC AND ABOVE REQUIREMENTS.24.AT ALL TIMES KEEP PREMISES AND BUILDING IN NEAT AND ORDERLY CONDITION CLEANED ON A DAILYBASIS WITH ALL DEBRIS BEING REMOVED FROM THE SITE DAILY. FOLLOW EXPLICITLY ANY INSTRUCTIONSOF THE OWNER'S REPRESENTATIVE. AFTER ALL TESTS AND ADJUSTMENTS HAVE BEEN COMPLETED, CLEANALL EQUIPMENT LEAVING EVERYTHING IN WORKING ORDER AT THE COMPLETION OF THIS WORK. CLEANLIGHTING FIXTURES, OUTLET BOX PLATES, PANEL AND CABINET INTERIORS AND EXTERIORS, ETC., OF DIRT,DUST, DEBRIS AND PAINT, AFTER ALL OTHER TRADES HAVE COMPLETED THEIR WORK.25.DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER OPERATION OF EACH OF THE SYSTEMSCOMPRISING THIS CONTRACT BEFORE FINAL PAYMENT.26.AT THE END OF THE PROJECT THE CONTRACTOR SHALL MEASURE THE LOADING ON EACHPANELBOARD AND VERIFY THAT THE EQUIPMENT IS NOT LOADED TO MORE THAN 80% OF THE NAMEPLATERATING. IF LOAD MEASUREMENTS SHOW OTHERWISE THE CONTRACTOR SHALL INFORM THE ARCHITECTAND ENGINEER IMMEDIATELY AND SHUT OFF NON CRITICAL LOADS UNTIL THE SYSTEM CAN BE MODIFIED TOWITHIN PROPER LOAD RATINGS.27.IF REQUIRED LOADS SHALL BE ADJUSTED ON PANELS, DISTRIBUTION PANELS, SWITCHBOARDS, ETC.SO THAT LOADING ON EACH PHASE IS WITHIN 10% OF EACH OTHER.28.PROVIDE TEMPORARY TELEPHONE AND ELECTRICAL SERVICES ADEQUATE IN SIZE FOR HEATING, FORTHE USE OF ALL TRADES AND FOR THE LIGHTING OF EACH ROOM DURING CONSTRUCTION (20FOOTCANDLES MIN.). TEMPORARY WIRING SHALL BE TO OSHA REQUIREMENTS. TEMPORARY SERVICE CANBE EXTENDED FROM THE OWNER'S EXISTING POWER DISTRIBUTION SYSTEM OR A SEPARATE UTILITYSERVICE. THE OWNER MUST APPROVE OF THE POINT OF SUPPLY, THE METHOD OF EXTENSION AND THEROUTING OF NECESSARY TEMPORARY FEEDERS. THE CONTRACTOR SHALL PAY FOR ALL COSTSASSOCIATED WITH A UTILITY TEMPORARY POWER SERVICE IF REQUIRED. ALL 120 VOLT SINGLE PHASE 15AND 20 AMP RECEPTACLES USED BY WORKMEN SHALL BE PROTECTED BY A GFCI. PROVIDE A TEMPORARYTELEPHONE SERVICE FOR THE USE OF ALL TRADES DURING CONSTRUCTION.29.DO ALL CUTTING AND PATCHING IN EXISTING CONSTRUCTION AS NECESSARY FOR INSTALLATION OFTHIS WORK. HAVE CUTTING DONE BY SKILLED MECHANICS AS CAREFULLY AS POSSIBLE AND WITH ASLITTLE DAMAGE AS POSSIBLE.30.DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT IS A PART OF THE ELECTRICAL WORK. REFER TOTHE DRAWINGS FOR EXACT REQUIREMENTS.SECTION 16050 - BASIC MATERIAL AND METHODS1.ALL BOXES AND CONDUIT SHALL BE RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE INDEPENDENTOF THE CONDUIT SYSTEM. ALL BOXES SHALL BE 4" SQUARE BOXES MINIMUM WITH RAISED COVERSSUITABLE FOR THE WALL MATERIAL.2.RACEWAYS:A.)CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL (RGS) OR INTERMEDIATE GRADE STEEL(IMC) IN EXTERIOR MASONRY WALLS, IN MASONRY WALLS BELOW GRADE, IN CRAWL SPACES, INCONCRETE FLOORS, IN SLABS, AND IN DAMP OR WET LOCATIONS. EXPOSED CONDUITS IN HIGHTRAFFIC AREAS WHERE CONDUITS ARE SUBJECT TO PHYSICAL ABUSE SHALL BE HEAVY WALL RIGIDGALVANIZED STEEL TO A LEVEL OF 8 FEET ABOVE THE FINISHED FLOOR. ALL OTHER INTERIORCONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT), UNLESS OTHERWISE NOTED ON THEDRAWINGS OR WITHIN THESE SPECIFICATIONS. CONDUITS SHALL BE 1/2" TRADE SIZE, MINIMUM,UNLESS OTHERWISE NOTED ON THE DRAWINGS OR WITHIN THESE SPECIFICATIONS.B.)CONDUIT BELOW SLABS AND UNDERGROUND SHALL BE SCHEDULE 40 PVC CONDUIT. FOR CONDUITSLARGER THAN 3" PROVIDE RGS OR IMC LONG SWEEP ELBOWS FOR STUB UPS INTO ELECTRICALEQUIPMENT. PROVIDE RGS TRANSITIONS WHERE SUBJECT TO PHYSICAL DAMAGE.C.)FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOXES TO RECESSED LIGHTING FIXTURES, 6FT. IN LENGTH. METAL CLAD (TYPE MC) CABLE OR MANUFACTURED WIRING SYSTEMS MAY BE UTILIZEDIN LIEU OF BRANCH CIRCUIT EMT CONDUIT. INSTALLATION OF MC CABLE SHALL COMPLY WITH ARTICLE334 OF THE NATIONAL ELECTRICAL CODE. INSTALLATION OF MANUFACTURED WIRING SYSTEMS SHALLCOMPLY WITH ARTICLE 604 OF THE NATIONAL ELECTRICAL CODE. ALL BRANCH CIRCUIT HOMERUNCONDUITS WITHIN THE CEILING SPACE COMPLETE TO THE PANELBOARDS SHALL BE IN EMT CONDUIT.D.)CONDUIT CONNECTIONS TO MOTORS SHALL BE FLEXIBLE METAL CONDUIT "SEAL-TITE" TYPE "UA" ASMANUFACTURED BY THE AMERICAN BRASS COMPANY OR EQUIVALENT AND SHALL BE OF THE SAMESIZE AS THE FEEDER CONDUIT.E.)CONDUIT CONNECTIONS TO UNDERCABINET TYPE LIGHTING FIXTURES SHALL BE 3/8" FLEXIBLE METALCONDUIT OR MC TYPE CABLE FROM THE WALL OUTLET BOX TO THE FIXTURE HOUSING.F.)CONDUITS PASSING FROM INTERIOR OF THE BUILDING TO EXTERIOR OF THE BUILDING SHALL BEFILLED WITH A UL APPROVED MATERIAL TO PREVENT CIRCULATION OF WARM AIR TO THE EXTERIORRACEWAY PER NEC SECTION 300.7(A).3.WIRING DEVICES:A.)LOCAL LIGHT SWITCHES SHALL BE 20 AMPERE, 120/277 VOLTS, AC SPECIFICATION GRADE, WITHGROUNDING TERMINAL, AS MANUFACTURED BY HUBBELL, OR EQUIVALENT, #CS-122 SERIES.B.)DUPLEX RECEPTACLES SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING. GENERAL PURPOSE"SPECIFICATION GRADE" DUPLEX RECEPTACLES: HUBBELL #CR5352.C.)GROUND FAULT CIRCUIT INTERRUPTER DUPLEX RECEPTACLES WHERE INDICATED ON THE DRAWINGSOR WHERE REQUIRED BY CODE, SHALL HAVE AN INTEGRAL GROUND FAULT PROTECTOR FORPERSONNEL PROTECTION (5MA) AND SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING: HUBBELL#GFR5352. GROUND FAULT RECEPTACLES SHALL NOT BE THRU-WIRED. PROVIDE INDIVIDUAL DUPLEXRECEPTACLES AS SHOWN ON THE DRAWINGS.D.)WIRING DEVICES (SWITCHES, RECEPTACLES, ETC.) SHALL BE IVORY UNLESS OTHERWISE INDICATED.VERIFY COLOR WITH THE ARCHITECT. PROVIDE (STAINLESS STEEL)(PLASTIC COVERPLATES WITHCOLOR) TO MATCH DEVICES. BOTH THE WIRING DEVICES AND THE COVERPLATES SHALL BE BY THESAME MANUFACTURER. IN UNFINISHED AREAS, USE CADMIUM PLATED, ROUND CORNER, STEELCOVERPLATES AND SURFACE MOUNTED OUTLET BOXES. EMERGENCY RECEPTACLES AND SWITCHESSHALL BE REDE.)MANUAL MOTOR STARTERS SHALL BE CUTLER-HAMMER TYPE "MS" SERIES OR EQUIVALENT, WITHPILOT LIGHT, OVERLOADS AND ON/OFF SWITCH; FLUSH MOUNTED IN FINISHED AREAS. MANUAL MOTORSTARTERS SHALL BE MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, SIEMENS OR ALLENBRADLEY.F.)THE FOLLOWING ARE EQUIVALENT WIRING DEVICES:1.RECEPTACLES: #5362 SERIES MANUFACTURED BY PASS AND SEYMOUR OR LEVITON.2.LIGHT SWITCHES: PASS AND SEYMOUR #20AC1 SERIES OR LEVITON #1221 SERIES.4.WIRE AND CABLE FOR BRANCH CIRCUITS AND FOR FEEDERS SHALL BE 600 VOLT, TYPE THHN/THWNCOPPER ONLY, UNLESS OTHERWISE INDICATED ON THE DRAWINGS. MINIMUM SIZE FOR POWER ANDLIGHTING BRANCH CIRCUITS SHALL BE #12. FLEXIBLE CORD SHALL BE HEAVY DUTY TYPE 'SO' WITH ANEQUIPMENT GROUND CONDUCTOR.5.SAFETY SWITCHES SHALL BE NEMA HEAVY DUTY FUSIBLE OR NONFUSIBLE TYPE AS INDICATED ON THEDRAWINGS, AND SHALL BE SUITABLE FOR THE VOLTAGE AND CURRENT RATINGS AS SHOWN ON THEDRAWINGS. THEY SHALL CONTAIN AN EXTERNAL PAD-LOCKABLE OPERATING HANDLE.6.FUSES RATED 600 AMPERES OR LESS, 600 VOLTS OR LESS, SERVING ALL LOADS SHALL BE UL CLASS RK1,DUAL ELEMENT, TIME DELAY AS MANUFACTURED BY BUSSMANN, OR APPROVED EQUIVALENT ASMANUFACTURED BY RELIANCE FUSE, GOULD SHAWMUT OR LITTELFUSE, GENERAL ELECTRIC OR S & C.7.DISCONNECT SWITCHES AND MOTOR STARTERS SHALL BE MANUFACTURED BY SQUARE D, GENERALELECTRIC, SIEMENS, CUTLER HAMMER, OR ALLEN BRADLEY.8.ANY CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS AND WALLS SHALL BE FIRE STOPPEDPRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE SEALED IN ACCORDANCE WITH UL FIRERESISTANCE HANDBOOK, VOLUME II AND SHALL BE RATED TO MATCH THE FIRE RATING OF THE FLOORS,SHAFTS OR WALLS PENETRATED.9.RACEWAY INSTALLATION:A.)CONDUITS SHALL BE CONTINUOUS AND SECURED TO ALL BOXES IN SUCH A MANNER THAT EACHCONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS FROM THE POINT OF SERVICE TO ALLOUTLET BOXES. RUN CONDUITS CONCEALED UNLESS OTHERWISE INDICATED.B.)IN REMODELED AREAS WHERE IT IS NOT POSSIBLE TO INSTALL CONCEALED CONDUIT, PERMISSIONMUST BE OBTAINED FROM THE ARCHITECT TO RUN SURFACE WIREMOLD OR CONDUIT. THE ROUTINGAND ELEVATION OF SUCH SURFACE MOUNTED RACEWAYS MUST BE COORDINATED WITH THEARCHITECT BEFORE INSTALLATION. EXPOSED RACEWAYS SHALL BE PAINTED TO MATCH ADJACENTFINISHES.C.)INDIVIDUAL BRANCH CIRCUITS ARE SHOWN ON THE DRAWINGS FOR CLARITY. MULTIWIRE BRANCHCIRCUITS MAY BE UTILIZED AS DEFINED BY N.E.C. ARTICLE 210.4. NEUTRAL CONDUCTORS INRECEPTACLE CIRCUITS SERVING DATA EQUIPMENT LOADS SHALL NOT BE SHARED.D.)WIRING FROM LEGALLY REQUIRED EMERGENCY AND STANDBY POWER GENERATION SOURCES SHALLBE KEPT INDEPENDENT OF EACH OTHER AND INDEPENDENT OF ALL OTHER BRANCH CIRCUIT WIRING,AND SHALL NOT ENTER THE SAME RACEWAY, CABLE, BOX, OR CABINET WITH OTHER WIRING, UNLESSSPECIFICALLY ALLOWED BY THE NATIONAL ELECTRICAL CODE.10.WIRE AND CABLE INSTALLATION:A.)PULL WIRE AND CABLES INTO CONDUIT USING IDEAL INDUSTRIES "YELLOW 190", OR EQUIVALENT.B.)CONNECT #10 AND SMALLER WIRESC.)COLOR CODE WIRE AND CABLE FOR CIRCUITS AS CALLED FOR IN THE NATIONAL ELECTRICAL CODE.COLOR CODING OF FEEDERS SHALL BE BY MEANS OF COLORED TAPE AT TERMINALS AND ALL POINTSOF ACCESS INCLUDING JUNCTION BOXES. COLOR CODE AS FOLLOWS:208/120V-3PH-4Wa.PHASE ABLACKb.PHASE BREDc.PHASE CBLUEd.NEUTRALWHITEe.GROUNDGREEN11.WIRING DEVICE INSTALLATION:A.)ADJACENT DEVICES SHALL BE MOUNTED IN GANGED BOXES WITH COMMON COVER PLATES.B.)VERIFY MOUNTING HEIGHTS AND LOCATIONS WITH THE ARCHITECT BEFORE ROUGH-IN. REFER TODETAILS AND INTERIOR WALL ELEVATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS.C.)OUTLETS SHALL NOT BE INSTALLED BACK TO BACK.D.)ALL RECEPTACLES SHALL BE MOUNTED WITH THE GROUND OPENING ABOVE THE PHASE ANDNEUTRAL OPENINGS.E.)ALL DEVICES SHALL BE SECURED WITH MORE THAN A SINGLE SCREW.12.ALL HARDWARE, SUPPORTS, HANGERS, BRACKETS, ANGLE IRON, CHANNELS, RODS AND CLAMPSNECESSARY TO INSTALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED TO SUIT THE FIELD CONDITIONS ANDTHE APPLICATIONS INTENDED AS SHOWN ON THE DRAWINGS. THE USE OF PERFORATED STRAPS IS NOTPERMITTED.13.ALL EQUIPMENT MOUNTED ON EQUIPMENT ROOM WALLS SHALL BE ATTACHED TO 3/4" PLYWOODBOARDS, PAINTED WITH FIRE RESISTANT PAINT.14.DISCONNECT SWITCHES MOUNTED ON OR ADJACENT TO MECHANICAL AND BUILDING EQUIPMENTSHALL BE LOCATED TO ALLOW THE PROPER WORKING CLEARANCE AS DEFINED IN ARTICLE 110 OF THENATIONAL ELECTRICAL CODE. THE ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTING MEANSAND OVERLOAD PROTECTION FOR ALL EQUIPMENT UNLESS SUCH EQUIPMENT IS FURNISHED WITH THESEITEMS IN THE EQUIPMENT PACKAGE.15.ELECTRICAL INSTALLATIONS IN HOLLOW SPACES, VERTICAL SHAFTS, AND VENTILATION ORAIR-HANDLING DUCTS SHALL BE MADE SO THAT THE POSSIBLE SPREAD OF FIRE OR PRODUCTS OFCOMBUSTION WILL NOT BE SUBSTANTIALLY INCREASED. OPENINGS AROUND ELECTRICAL PENETRATIONSTHROUGH FIRE-RESISTANT-RATED WALLS, PARTITIONS, FLOORS, OR CEILINGS SHALL BE FIRESTOPPEDUSING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. MAINTAIN A MINIMUM OF 24-IN.HORIZONTAL SEPARATION BETWEEN BOXES INSTALLED ON OPPOSITE SIDES OF WALLS OR PROVIDE ANAPPROVED FIRESTOPPING INTUMESCENT PUTTY PAD AND WRAP ELECTRICAL BOX TO MAINTAIN FIRERATING PER MANUFACTURER'S INSTRUCTIONS.SECTION 16500 - LIGHTING1.ALL LIGHT FIXTURES ARE LED TYPE. LED DRIVERS AND MODULESA.LED DRIVERS SHALL INCLUDE THE FOLLOWING FEATURES UNLESS OTHERWISE INDICATED:1.MINIMUM EFFICIENCY: 85% AT FULL LOAD.2.MINIMUM OPERATING AMBIENT TEMPERATURE: -20˚ C. (-4˚ F.)3.INPUT VOLTAGE: 120 - 277V (±10%) AT 60 HZ4.INTEGRAL SHORT CIRCUIT, OPEN CIRCUIT, AND OVERLOAD PROTECTION.5.POWER FACTOR: ≥ 0.95.6.TOTAL HARMONIC DISTORTION: ≤ 20%.7.COMPLY WITH FCC 47 CFR PART 15.8.SHALL PROVIDE DIMMING CAPABILITY AS INDICATED ON THE LIGHTING FIXTURE SCHEDULE.B.LED MODULES SHALL INCLUDE THE FOLLOWING FEATURES UNLESS OTHERWISE INDICATED1.COMPLY WITH IES LM-79 AND LM-80 REQUIREMENTS2.MINIMUM CRI 80 AND COLOR TEMPERATURE 3500˚ K UNLESS OTHERWISE SPECIFIED IN LIGHTING FIXTURESCHEDULE.3.MINIMUM RATED LIFE: 50,000 HOURS PER IES L70.4.LIGHT OUTPUT LUMENS AS INDICATED IN THE LIGHTING FIXTURE SCHEDULE.5.LED DRIVERS, MODULES, AND REFLECTOR SHALL BE ACCESSIBLE, SERVICEABLE, AND REPLACEABLE FROMBELOW THE CEILING.6.REFER TO LIGHTING FIXTURE SCHEDULE ON DRAWING E100 FOR DETAILS.7.WHERE LIGHT FIXTURES ARE CONNECTED TO MULTIWIRE BRANCH CIRCUITS, THE DISCONNECTING MEANSSHALL SIMULTANEOUSLY BREAK ALL THE SUPPLY CONDUCTORS TO ALL CIRCUITS.8.RECESSED AND SURFACE MOUNTED FIXTURES MOUNTED IN, OR ON CEILINGS OTHER THAN ACCESSIBLELAY-IN CEILING SYSTEMS, SHALL BE SECURELY SUPPORTED IN A MANNER APPROVED BY THE ARCHITECT.MOUNTING SHALL ALSO BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE ARTICLE 410, AND ASRECOMMENDED BY THE FIXTURE MANUFACTURER.9.RECESSED FIXTURES IN ACCESSIBLE LAY-IN CEILING SYSTEMS SHALL BE SUPPORTED AS FOLLOWS:A.)THE GRID SYSTEM TEES SHALL BE SUPPORTED AT EACH CORNER OF EACH FIXTURE WITH ASUSPENDED CEILING SUPPORT WIRE UP TO A BUILDING STRUCTURAL MEMBER, OR UP TO THESTRUCTURAL DECK.B.)EACH FIXTURE SHALL ALSO BE SECURELY FASTENED TO THE GRID SYSTEM TEES BY MECHANICALMEANS, SUCH AS BOLTS, SCREWS, RIVETS OR BY CLIPS IDENTIFIED FOR USE WITH THE TYPE CEILINGFRAMING MEMBER INSTALLED.10.ALL LIGHTING FIXTURES (INCLUDING "NORMALLY-OFF" EMERGENCY FIXTURES) THAT ARE CAPABLE OFBEING AIMED SHALL BE AIMED BY THE CONTRACTOR FOR THE OPTIMUM COVERAGE OF THEIR TASK, TO THESATISFACTION OF, AND UNDER THE DIRECTION OF THE ARCHITECT.SECTION 16700 - COMMUNICATIONS1.COMBINATION TELEPHONE/DATA OUTLET BOXES SHALL BE 4 INCHES SQUARE WITH SINGLE GANG PLASTERRINGS, UNLESS OTHERWISE NOTED.2.TELEPHONE-ONLY, DATA-ONLY, FAX AND PAY TELEPHONE OUTLETS SHALL BE SIMILAR.3.BLANK COVERPLATES SHALL BE PROVIDED FOR ALL UNUSED OUTLETS.4.ALL CONDUITS REQUIRED FOR COMBINATION TELEPHONE/DATA OUTLETS AS SHOWN ON THE DRAWINGSSHALL BE INSTALLED COMPLETE WITH CABLES INSTALLED BACK TO NETWORK RACK.5.CONDUITS SHALL BE 3/4" MINIMUM. EMPTY CONDUITS SHALL BE PROVIDED WITH PULL-STRING6.PROVIDE CONDUIT FROM EACH OUTLET UP TO THE NEAREST ACCESSIBLE CORRIDOR CEILING SPACE ANDPROVIDE A PLASTIC GROMMET AT EACH STUB.7.PROVIDE MISCELLANEOUS COMMUNICATION SYSTEM DEVICES AS SHOWN AND SPECIFIED ON THEDRAWINGS.8.INCLUDE SUFFICIENT WIRING, CONDUIT TERMINATIONS, ELECTRICAL BOXES, AND ALL OTHER NECESSARYMATERIAL AS RECOMMENDED BY THE SYSTEM SUPPLIERS.ELECTRICAL SPECIFICATIONSP R O FESSIONAL E N GI NEER - STATE OF NEVADANo. 024316 CHARLES SPARSONSExpiresELECTRICAL12/31/21