Cross Section with Sheetrock FinalKEEP FASTENERS INTO TRUSS
16" BACK FROM WALL
Ix OR 2x BLOCKING FASTENED TO
WALL PLATE, BETWEEN CHORDS,
FOR DRYWALL EDGE FASTENING
-- OR PROVIDE DRYWALL CLIPS
2x TRUSS TIE
- TYPICAL
LIFTING / BOWING OF BOTTOM
CHORD OF TRUSS
—MANUFACTURED
SLOTTED CLIP
_ -- KEEPS WALL
STATIONARY BUT
ALLOWS TRUSS TO MOVE
UP AND DOWN
-- STC ROOF -TRUSS
CLIPS BY SIMPSON
OR EQUAL
TRUSS
PLATE
I& IN. TO
FIRST SHEETROCK
FASTENER
NON -SEARING INT. WALL ATTACHMENT TO TRUSSES
ROOF SHEATHING
2x4 OUTRIGGERS LET IN
THROUGH WALL AT MAX.
48" O.C.
2. GYP, BD. BACKING
OR DRYWALL CLIPS
TRUSS MANUFACTURER TO AT PARALLEL WALLS
VERIFY DETAILS
TRUSS FRAME CzABLE END ROOF
DOUBLE TOP PLATE
TRUSSES
'HI" FRAMING ANCHOR
TRUSS TO TOP PLATE
AT EACH END
DOUBLE TOP PLATE
SHEATHING
EDGE NAILING
SHEATHING
TRUSS
CLIP
DS DRYWALL I
CLIPS OR
WOOD NAILER S
TlxSWINGLEMOLD
2x BARGE RAFTER
2x TRUSS BRACE
MIN, 3 PER SET
RAFTERS
"HI" FRAMING ANCHOR
TRUSS TO TOP PLATE
AT EACH END
SHEATHING
EDGE NAILING
SHEATHING
12 TYPICAL TRUSS ROOF:
7 � ASPHALT SHINGLES
ZIP SYSTEM 5/8" TtG ROOF SHEATHING
PRE-ENGINEERED TRUSSES o 24" 0.c.7
R49 BLOWN -IN INSULATION �
PROPER VENT
RAISED TRUSS ENERGY HEAL
TOTAL HEAL HEIGHT 12 INCHES O
�Ix3 STRAPPING s 16" o.c.
TYPICAL 2x6 SIDING EXTERIOR WALL:
O 1/2" CEILING SHEETROCK
VINYL HORIZONTAL SIDING
TAPED E SANDED
Q
Il/32" ZIP SYSTEM WALL SHEATHING
W
2x(. STUDS ® 24" 0
W
I
RI9 CELLULOSE BLOWN -IN INSULATION
w DOUBLE 2xIO WINDOW HEADER
V%
1/2" DRYWALL
(L w/ 2 1/2" THK RIGID INSULATION
z
TAPED 4 SANDED
:3
lL
Q
O
z FLOATING HARDWOOD FLOORING
r
EXISTING THICK FLOORING
F
mq EXISTING EXPOPSEDBLOOR JOIST
EXISTING SIDING EXTERIOR WALL:
NEW VINYL HORIZONTAL SIDING
EXISTING WALL SHEATHING
EXISTING STUDS SYSTEM
FILL BAYS WITH CLOSED CELL
INSULATION
1/2" DRYWALL
TAPED 4 SANDED
EXISTING BEAM SYSTEM
II 1/8" DP. I -JOISTS o 16" o.c.
1/2" SHEETROCK
FIRST -FLOOR FLOOR SYSTEM:
NEW FINISHED FLOOR
EXISTING TOG SUBFLOORING
EXISTING BEAM t JOISTS SYSTEM
EXISTING FOUNDATION WALL
CLEAN FOUNDATION WALLS
SPRAY CLOSED CELL
p`
INSULATION ON ALL WALLS
AND BAND JOIST BEAMS
a
R VALUE TO MEET CODE
a
.A
D
�p
p'vo�
TYP/CAL 7RU55 ROOF:
ASPHALT SHINGLES
ZIP SYSTEM 5/8" Tr. ROOF SHEATHING
PRE-ENGINEERED TRUSSES m 24" o.c.
R49 BLOWN -IN INSULATION
RAISED TRUSS ENERGY HEAL
TOTAL HEAL HEIGHT 12 INCHES
PROPER VENT
ly
UJ
(L
(L
0
Q
z
3
EXISTING JOIST SYSTEM
- LEAVE EXPOSED
EXISTING BEAM SYSTEM
:a
.A
D
CLEAN FOUNDATION WALLS
SPRAY CLOSED CELL
INSULATION ON ALL WALLS
p"
AND BAND JOIST BEAMS
R VALUE TO MEET CODE
a
a
Do
vn�
TYPICAL 2.6 SIDING EXTERIOR WALL:
VINYL HORIZONTAL SIDING
Il/32" ZIP SYSTEM WALL SHEATHING
2x6 STUDS ® 24" o.c.
RI9 CELLULOSE BLOWN -IN INSULATION
1/2" DRYWALL
TAPED 4 SANDED
RIMBOARD
CLOSED CELL INSULATION
EXISTING SIDING EXTERIOR WALL:
NEW VINYL HORIZONTAL SIDING
EXISTING WALL SHEATHING
EXISTING STUDS SYSTEM
FILL BAYS WITH CLOSED CELL
INSULATION
1/2" DRYWALL
TAPED < SANDED
EXISTING FOUNDATION WALL
Ln
00
Ul
Q �
J Q
Z
z
c
a0-
a
L ;
Q �
z'
L O
1> W
a W ( h
z N �/
I �
Q Q l V
O
LL Q FH
n C
'v a `U
V '
Ld
c ra_u aY
TWN
o \vm eY
TLN
SCALL
NONE
-TAW
DATE.
JUNE.2020
"'T
a�T