Loading...
jb_0103126_00_a_acad_b_01 - SignedINDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NN 12/23/2020 UPDATED BOS AND MP PER SURVEY. **** **** **** **** LICENSE GENERAL NOTES (E) DRIVEWAY 0 20'40' Scale:1" = 20'-0' PROPERTY PLAN (E) DRIVEWAY Front Of House SV SV SV Pitch4/12MP1Pitch10/12MP2Pitch10/12MP3Scale:1/16" = 1' SITE PLAN 01'32'16' LEGEND MP3 40 80 40 80 Comp Shingle 2 Stories MP2 40 170 40 170 Comp Shingle 2 Stories MP1 15 170 15 170 Comp Shingle 2 Stories #SSTAMPMA #ESTAMPMA A A NTS TYPICAL PV SIDE VIEWSV Scale: 1 1/2" = 1' STANDOFFS1 #SSTAMPMA #SSTAMPMA LICENSEGENERAL NOTESMAIN PANEL SPECSGROUND SPECS AC Z GNDGND Y 9 N EGC L2 L18 W N EGC L2 L18 W N EGC L2 L18 W 7 L1NEGCL2 POI Z Y W 7 8 9 #ESTAMPMA LICENSEMODULE SPECS INV 1 INVERTER SPECSGENERAL NOTES INV 2 INV 3 AC DC GNDGND B GND C V240 L2 L1 N EGC GND N Inverter 1 EGC DC- DC+ DC- DC+ A EGC DC- DC+ DC- DC+ MP 1: 1x14 MP 2: 1x14 EGC DC- DC+MP 3: 1x8 A PV Gnd B C 1 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC1 2 3 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC2 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC3 4 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC4 5 Voc*= VDC Isc = ADC Vmp = VDC Imp= ADC5 6 Vmp = VAC Imp= AAC6 #ESTAMPMA CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 19 Pilgrim Dr OPERATING VOLTAGE = 240V JB-0103126-00 LB-130089-10X Per Code: NEC 690.31.G.3 Label Location: (C)(CB)(JB) LB-050081-10X Per Code: NEC 690.13.B Label Location: (DC) (INV) 690_53_2017 Per Code: NEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: 690.41.B Label Location: (DC) (INV) LB-010001-10X Per Code: CEC 690.13.B Label Location: (DC) (CB) LB-050082-10X Per Code: NEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: NEC 690.54 Label Location: (AC) (POI) LB-070005-10X Per Code: NEC 690.13.B Label Location: (AC)(POI) LB-070039-10X Per Code: NEC 705.12.B.2.3.b Label Location: (POI) LB_040108_10X Per Code: NEC 690.56.C.3 Label Location: (INV) LB-040008-10X Per Code: NEC 690.64.B.4 Label Location: (D) (POI) LB-040009-10X Per Code: NEC 705.12.B.3 Label Location: (POI) LB-060046-10X Per Code: CEC 690.13.B Label Location: (POI) LB-070016-10X Label Location: (DC) (INV) LB-250001-10X Per Code: 690.56(C)(1)(b) Label Location: ABB/Delta Solivia Inverter LB-250002-34X Per Code: 690.56(C)(1)(a) Label Location: SolarEdge/Delta M-Series Inverter (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set LB-040137-10X Per Code: NEC 408.4 Label Location: (BLC) LB-040144-10X Per Code: NEC 220 Label Location: (BLC) LB-200025-10X Per Code: NEC 312.8.A(3) Label Location: (MP) LB-030142-10X Per Code: NEC 705.12(B)(3) Label Location: (MP) LB-040141-10X Per Code: Label Location: (MP) LB-040139-10X Per Code: Label Location: (MP) LB-040140-10X Per Code: Label Location: (MP) LB-040138-10X Per Code: Label Location: (MP) LB-200011-10X Per Code: NEC 705.12(B)(3) Label Location: (MP) LB_200127_10X Per Code: NEC 705.12.B.2.3.c Label Location: (MP) LB-200110-10X Per Code: Per 706.7(D) label to be marked in field Label Location: (MP) (MP): Main Panel (BLC): Backup Load Center (AC): AC Disconnect Label Set ✁✂✄☎✆✝✞ ✟ ✠ ✡ ☛☎✆✠✄✡✆☛✝ ☞ ✠✌☛✠✌✡ ✍✠ ✎ ✏ ☞✠✄✄ ✑ ✌☞☞✌✡☛ ✍ ✒ ✍ ✓ ✠✏ ✔ ✆ ✕ ✌☞✆☞✌✒✆✞☛✂☛✄✏ ☞✆☎✞✝☛✄✆☞✄✠☞✖✂✝✠✄ ✗ ✓✠✏ ✔✆ ✕ ✌☞ ✘✄✄✆ ✕ ✠✑✌☞☞✌✡☛ ✍ ✂✄✝✆ ✡ ☛✌✂✡✠☎✂✡☛✁✠✑☞✂☛☛✠✡ ✏ ☞✆☎✞✝☛✑✌☞☞✌✡☛ ✍ ✙ ✆☞HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP ✚✆✝✞ ✟ ✠✡☛✛✜✢✢ ✣ ✤✜✥✢ ✣ ✢✢✤✦✠✖✧✚✌☛✠✕✌✄☛✠ ✎ ✏✆☞☛✠☎ ★ ✩✌✍ ✪✫✬✪✢✤✭✫★✮✤✯✩ ✰✱✲ ✳ ✴✵✶✷✸✹✴✺ ✻✼✽✾ ✿ ❀✼❁✼❂❃❄❅❆❇❈✾❉❈ ❊ ❋ ✼●❍❈❆❂❆ ❊■ for composition shingle roofs ❏❑▲▼◆❖◗ ❖❘❙ ❚ ❯❱✺✴❲❳❨❩❳❬✳✴✵❲❨❩✴❳❭✴✷✹✴✺✲✴✳❩❨❩✴❳✳❪❩❳❬✵✱✷✴✴❭✳ ❚ ❫✴✷❴✳❵❩❨❪✶✵✵❛✱✲ ❜ ✴✺✲✶❨❩❝✵✱❞✴❡❲✵✱✳ ❚❢❲❨✴❝✴❳❡❩❳❬ ❣ ❤ ✐ ✵❩✳❨✱❡❪✶✷❡❵✶✷✱✹✷✱✶❨✱✳✳❨✷❲✹❨❲✷✶✵✶❳❡✱✵✱✹❨✷❩✹✶✵❝✴❳❡ ❚❛❥❜✴✺✲❪✶✳✶❣❤❦❧♠♥❜✵✶✳✳ ♦ ❢ ♣ ❩✷✱✶❨❩❳❬❵❪✱❳❩❳✳❨✶✵✵✱❡❲✳❩❳❬✺✴❡❲✵✱✳❭✷✴✺DQ\PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´ 6SHFL¿FDWLRQV ❚ ✱✳❩❬❳✱❡❭✴✷✲❩❨✹❪✱❡✷✴✴❭✳ ❚ ❳✳❨✶✵✵✳❩❳✲✴✷❨✷✶❩❨✶❳❡✵✶❳❡✳✹✶✲✱✴✷❩✱❳❨✶❨❩✴❳✳ ❚ ❛❥❜✴✺✲✳❲✲✲✴✷❨✳✺✴❡❲✵✱❵❩❳❡❲✲✵❩❭❨✶❳❡✳❳✴❵✵✴✶❡✲✷✱✳✳❲✷✱✳❨✴✉♠✲✳❭✲✱✷❣❤✈❧♠♥ ❚ ❫❩❳❡❨❲❳❳✱✵✷✱✲✴✷❨❨✴❢❥❜✇❧ ✐ ♠✉✶❳❡❧ ✐ ❦♠✳❨✶❳❡✶✷❡✳ ❚ ❛❥❜✴✺✲❬✷✴❲❳❡❩❳❬✲✷✴❡❲✹❨✳✶✷✱❣❤✵❩✳❨✱❡❨✴❣❤✈❧♠♥✶❳❡❣❤①②❧ ❚ ❛❥❜✴✺✲❝✴❳❡❩❳❬✲✷✴❡❲✹❨✳✶✷✱❣❤✵❩✳❨✱❡❨✴❣❤✈❧♠♥ ❚ ✇❳❬❩❳✱✱✷✱❡❭✴✷✳✲✶❳✳❲✲❨✴❧✈ ♣ ✶❳❡✹✶❳❨❩✵✱③✱✷✳❲✲❨✴✈① ♣ ❚ ❛✱✲❵❩✷✱✺✶❳✶❬✱✺✱❳❨✲✷✴❡❲✹❨✳✵❩✳❨✱❡❨✴❣❤❦✉②✉❭✴✷❵❩✷✱✲✴✳❩❨❩✴❳❩❳❬❡✱③❩✹✱✳ ❚❢❨❨✶✹❪✺✱❳❨✺✱❨❪✴❡❣❤✵❩✳❨✱❡❨✴❣❤✈✉④✈❭✴✷❫❩❳❡✷❩③✱❳✶❩❳ ⑤⑥⑦⑧ ⑨ ⑩ ❶ ❷❸❹❺❺ ❻ ❼❹❽❺ ❻❺❺❼❾⑩ ❿ ➀⑤➁❷⑩ ➂ ➁➃❷⑩ ➄ ➅⑥ ➆ ❷⑩➇ ➈ ➉➁➊ ➋ ➌➍➋❺❼➎➌➈➏❼➐➉ ➑➒➓➃➇⑥⑦⑧ ⑨ ⑩ ❶ ❷➇⑥⑩➃❶⑥❷⑦➆⑩➁❷⑩➁ ❶ ➊⑩➄➅➆⑩➃➃ ➔ ➁ ➆ ➆➁ ❶ ❷ ➊ → ➊ ➣ ⑩➅ ↔ ⑥➂➁ ➆ ⑥➆➁→⑥⑧❷➓❷➃➅ ➆⑥➇⑧⑦❷➃⑥ ➆ ➃⑩➆❿➓⑦⑩➃ ↕ ➣⑩➅ ↔ ⑥➂➁ ➆ ➙ ➃➃⑥➂⑩➔➁➆➆➁ ❶ ❷ ➊➓➃⑦⑥ ❶ ❷➁➓❶⑩➇➓❶❷➒⑩➔➆➓❷❷⑩ ❶ ➅ ➆⑥➇⑧⑦❷➔➁➆➆➁ ❶ ❷ ➊ ➛ ⑥ ➆ HDFKSURGXFW7KHHQGXVHUGRFXPHQWDWLRQVKLSSHGZLWK=HS6RODU¶VSURGXFWVFRQVWLWXWHVWKHVROHVSHFL¿FDWLRQVUHIHUUHGWRLQWKHSURGXFWZDUUDQW\7KHFXVWRPHULVVROHO\UHVSRQVLEOHIRUYHULI\LQJWKHVXLWDELOLW\RI=HS6RODU¶VSURGXFWVIRUHDFKXVH6SHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH3DWHQWVDQG$SSV]VSDWVFRP 1H[W/HYHO390RXQWLQJ7HFKQRORJ\ ]HSVRODUFRP ➜➝➞ ➟ ➝➠➡➠➢➤ ➥➝➦➠➢➧➠ ➨ ➩ ➫➝➭➯ Part No. 850-1633 Listed to UL 2703 and UL 2582 &DSWXUHG:DVKHU/DJ Part No. 850-1631-001 850-1631-003 )ODVKLQJ$FFHVVRU\ Part No. 850-1634 Listed to UL 2703 and UL 2582 $UUD\6NLUW Part No. 850-1608 or 500-0113 Listed to UL 2703 ➲➳➧ ➟ Part No. 850-1606 or 850-1421 Listed to UL 2703 (QG&DS Part No. (L) 850-1586 or 850-1460 (R) 850-1588 or 850-1467 ➵➜➸➧➳➡➜➫➧➟ Part No. 850-1509 Listed to UL 1565 *URXQG=HS9 Part No. 850-1511 Listed to UL 467 and UL 2703 ➺➠➢➡➳➫➝➭➯ Part No. 850-1388 or 850-1613 Listed to UL 2703 /HYHOLQJ)RRW Part No. 850-1397 Listed to UL 2703 ✁✂✄☎✆✝✞✟✠✞✁✡✂h^ͳEͳ'ZDEzͳ/d>zͳ&ZEͳ:WEͳ,/Eͳh^dZ>/ͳd,Ed,Z>E^ͳh<ͳ/^Z>ͳdhZ<zͳ,hE'Zzͳ>'/hDͳZKDE/ͳh>'Z/POWER OPTIMIZER ĞƌƟĮĞĚĞƉŽŵƉĂƟďůĞ ☛☞ďƌĂĐŬĞƚ  ƩĂĐŚĞƐƚŽŵŽĚƵůĞĨƌĂŵĞǁŝƚŚŽƵƚƐĐƌĞǁƐͲƌĞĚƵĐĞƐŽŶͲƌŽŽĨ ůĂďŽƌĂŶĚŵŽƵŶƟŶŐĐŽƐƚƐ  WŽǁĞƌŽƉƟŵŝnjĞƌĞƋƵŝƉŵĞŶƚŐƌŽƵŶĚĞĚƚŚƌŽƵŐŚƚŚĞďƌĂĐŬĞƚ  hƉƚŽϮϱйŵŽƌĞĞŶĞƌŐLJ  ^ƵƉĞƌŝŽƌĞĸĐŝĞŶĐLJ;ϵϵ͘ϱйͿ  DŝƟŐĂƚĞƐĂůůƚLJƉĞƐŽĨŵŽĚƵůĞŵŝƐŵĂƚĐŚůŽƐƐĞƐ͕ĨƌŽŵ ŵĂŶƵĨĂĐƚƵƌŝŶŐƚŽůĞƌĂŶĐĞƚŽƉĂƌƟĂůƐŚĂĚŝŶŐ  &ůĞdžŝďůĞƐLJƐƚĞŵĚĞƐŝŐŶĨŽƌŵĂdžŝŵƵŵƐƉĂĐĞƵƟůŝnjĂƟŽŶ  EĞdžƚŐĞŶĞƌĂƟŽŶŵĂŝŶƚĞŶĂŶĐĞǁŝƚŚŵŽĚƵůĞͲůĞǀĞůŵŽŶŝƚŽƌŝŶŐ  DŽĚƵůĞͲůĞǀĞůǀŽůƚĂŐĞƐŚƵƚĚŽǁŶĨŽƌŝŶƐƚĂůůĞƌĂŶĚĮƌĞĮŐŚƚĞƌ ƐĂĨĞƚLJ ✌✍✎ ✏ ✑ ✒✓✔✕✖✗✓✒✘✙✖ ✏ ✚ ✛✍✍✜✖✢✛✑✎✖✣✎✍✣✤✕✖✥ SolarEdge Power Optimizer - Zep CompatibleTM Module Add-On For North America P300-ZEP, P400-ZEP © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017. V.01. Subject to change without notice. SolarEdge Power Optimizer - Zep CompatibleTM Module Add-On For North America P400-ZEP WϯϬϬͳW ✦ ✧ ★✩✪✫ ✬ ✭✮✯✯✰✱✲★✳✴✯✮✵✶ WϰϬϬͲW;ĨŽƌϳϮΘϵϲͲĐĞůůŵŽĚƵůĞƐͿ ✷✸✹✺✻ ZĂƚĞĚ/ŶƉƵƚƉŽǁĞƌ;ϭͿ ✼✽✽✾✽✽✿ ďƐŽůƵƚĞDĂdžŝŵƵŵ/ŶƉƵƚsŽůƚĂŐĞ;sŽĐĂƚůŽǁĞƐƚƚĞŵƉĞƌĂƚƵƌĞͿ✾❀❀✽sĚĐ DWWdKƉĞƌĂƟŶŐZĂŶŐĞ ϴͲϰϴ ϴͲϴϬ sĚĐ DĂdžŝŵƵŵ^ŚŽƌƚŝƌĐƵŝƚƵƌƌĞŶƚ;/ƐĐͿ ϭϬ ϭϬ͘ϭ ĚĐ DĂdžŝŵƵŵ/ŶƉƵƚƵƌƌĞŶƚ ϭϮ͘ϱ ϭϮ͘ϲϯ ĚĐ DĂdžŝŵƵŵĸĐŝĞŶĐLJϵϵ͘ϱ й tĞŝŐŚƚĞĚĸĐŝĞŶĐLJϵϴ͘ϴ й KǀĞƌǀŽůƚĂŐĞĂƚĞŐŽƌLJ// KhdWhdhZ/E'KWZd/KEΈWKtZKWd/D/ZKEEddKKWZd/E'/EsZdZΉ DĂdžŝŵƵŵKƵƚƉƵƚƵƌƌĞŶƚ ϭϱ ĚĐ DĂdžŝŵƵŵKƵƚƉƵƚsŽůƚĂŐĞ ϲϬ sĚĐ KhdWhdhZ/E'^dEzΈWKtZKWd/D/Z/^KEEd&ZKD/EsZdZKZ/EsZdZK&&Ή ^ĂĨĞƚLJKƵƚƉƵƚsŽůƚĂŐĞƉĞƌWŽǁĞƌKƉƟŵŝnjĞƌ ϭ sĚĐ ^dEZKDW>/E D&WĂƌƚϭϱůĂƐƐ͕/ϲϭϬϬϬͲϲͲϮ͕/ϲϭϬϬϬͲϲͲϯ ^ĂĨĞƚLJ /ϲϮϭϬϵͲϭ;ĐůĂƐƐ//ƐĂĨĞƚLJͿ͕h>ϭϳϰϭ ❁❂❃❄❅❆❇ /E^d>>d/KE^W/&/d/KE^ DĂdžŝŵƵŵůůŽǁĞĚ^LJƐƚĞŵsŽůƚĂŐĞ ϭϬϬϬ sĚĐ ŝŵĞŶƐŝŽŶƐŝŶĐůƵĚŝŶŐŵŽƵŶƟŶŐďƌĂĐŬĞƚ;tdž>dž,Ϳ ϭϮϴdžϭϵϲdžϮϳ͘ϱͬϱdžϳ͘ϳϭdžϭ͘Ϭϴ ϭϮϴdžϭϵϲdžϯϱͬϱdžϳ͘ϳϭdžϭ͘ϯϳ ŵŵͬŝŶ ŝŵĞŶƐŝŽŶƐĞdžĐůƵĚŝŶŐŵŽƵŶƟŶŐďƌĂĐŬĞƚ;tdž>dž,Ϳ ϭϮϴdžϭϱϮdžϮϳ͘ϱͬϱdžϱ͘ϵϳdžϭ͘Ϭϴ ϭϮϴdžϭϱϮdžϯϱͬ ϱdžϱ͘ϵϳdžϭ͘ϯϳ ŵŵͬŝŶ tĞŝŐŚƚ;ŝŶĐůƵĚŝŶŐĐĂďůĞƐĂŶĚŵŽƵŶƟŶŐďƌĂĐŬĞƚͿ ϳϮϬͬϭ͘ϲ ϴϰϬͬϭ͘ϵ ŬŐͬůď /ŶƉƵƚŽŶŶĞĐƚŽƌDϰŽŵƉĂƟďůĞ KƵƚƉƵƚŽŶŶĞĐƚŽƌŽƵďůĞ/ŶƐƵůĂƚĞĚ͖DϰŽŵƉĂƟďůĞ KƵƚƉƵƚtŝƌĞ>ĞŶŐƚŚ Ϭ͘ϵϱͬϯ͘Ϭ ϭ͘Ϯͬϯ͘ϵ ŵͬŌ KƉĞƌĂƟŶŐdĞŵƉĞƌĂƚƵƌĞZĂŶŐĞ ͲϰϬͲнϴϱͬͲϰϬͲнϭϴϱ ȗͬȗ& WƌŽƚĞĐƟŽŶZĂƟŶŐ /WϲϴͬEDϲW ZĞůĂƟǀĞ,ƵŵŝĚŝƚLJ ϬͲϭϬϬ й ;ϭͿZĂƚĞĚ^dƉŽǁĞƌŽĨƚŚĞŵŽĚƵůĞ͘DŽĚƵůĞŽĨƵƉƚŽнϱйƉŽǁĞƌƚŽůĞƌĂŶĐĞĂůůŽǁĞĚ͘ Ws^z^dD^/'Eh^/E' ^K>Z'/EsZdZΈϮΉ ^/E'>W,^ ,ͳts^/E'>W,^d,ZW,^ ϮϬϴs d,ZW,^ ϰϴϬs DŝŶŝŵƵŵ^ƚƌŝŶŐ>ĞŶŐƚŚ;WŽǁĞƌKƉƟŵŝnjĞƌƐͿ ❀ϭϬ ϭϴ DĂdžŝŵƵŵ^ƚƌŝŶŐ>ĞŶŐƚŚ;WŽǁĞƌKƉƟŵŝnjĞƌƐͿ Ϯϱ Ϯϱ ϱϬ DĂdžŝŵƵŵWŽǁĞƌƉĞƌ^ƚƌŝŶŐ ϱϳϬϬ;ϲϬϬϬǁŝƚŚ ^ϳϲϬϬ,Ͳh^Ϳ ϱϮϱϬ ϲϬϬϬ ϭϮϳϱϬ ✿ WĂƌĂůůĞů^ƚƌŝŶŐƐŽĨŝīĞƌĞŶƚ>ĞŶŐƚŚƐŽƌ KƌŝĞŶƚĂƟŽŶƐ ❅❆❇ ;ϮͿ&ŽƌĚĞƚĂŝůĞĚƐƚƌŝŶŐƐŝnjŝŶŐŝŶĨŽƌŵĂƟŽŶƌĞĨĞƌƚŽ͗ŚƩƉ͗ͬͬǁǁǁ͘ƐŽůĂƌĞĚŐĞ͘ĐŽŵͬƐŝƚĞƐͬĚĞĨĂƵůƚͬĮůĞƐͬƐƚƌŝŶŐͺƐŝnjŝŶŐͺŶĂ͘ƉĚĨ͘ TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, time-based control, and backup. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240 V Feed-In Type Split Phase Grid Frequency 60 Hz Total Energy1 14 kWh Usable Energy1 13.5 kWh Real Power, max continuous2 5 kW (charge and discharge) Real Power, peak (10 s, off-grid/backup)2 7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10 s, off-grid/backup)7.2 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor Range (full-rated power)+/– 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency1,3 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C (86°F) MECHANICAL SPECIFICATIONS Dimensions1 1150 mm x 753 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight1 114 kg (251.3 lbs) Mounting options Floor or wall mount 1 Dimensions and weight differ slightly if manufactured before March 2019. 1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2 In Backup mode, grid charge power is limited to 3.3 kW. 3 AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) 753 mm (29.6 in) 147 mm (5.75 in) 1150 mm (45.3 in) Contact Tesla for additional information. TESLA.COM/ENERGY TYPICAL SYSTEM LAYOUTS PARTIAL HOME BACKUP WHOLE HOME BACKUP Main panelSub panel Solar Home loads Solar inverter Utility meter GridBackup Gateway Powerwall Backup loads Optional NA - BACKUP - 2019-06-11 Utility meter GridBackup Gateway including service disconnect Main panel Solar Whole home backup Solar inverter Powerwall Optional INVERTERSsolaredge.com Optimized installation with HD-Wave technology 6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK SRZHURSWLPL]HUV %XLOWLQPRGXOHOHYHOPRQLWRULQJ 2XWGRRUDQGLQGRRULQVWDOODWLRQ 2SWLRQDO5HYHQXHJUDGHGDWD$16,& &ODVV DFFXUDF\ 5HFRUGEUHDNLQJH඼FLHQF\ 4XLFNDQGHDV\LQYHUWHUFRPPLVVLRQLQJGLUHFWO\ IURPDVPDUWSKRQHXVLQJWKH6RODU(GJH6HW$SS )L[HGYROWDJHLQYHUWHUIRUORQJHUVWULQJV 8/6$FHUWLÀHGIRU&38&5XOHJULGFRPSOLDQFH ,QWHJUDWHGDUFIDXOWSURWHFWLRQDQGUDSLG VKXWGRZQIRU1(&DQGSHUDUWLFOH DQG ([WUHPHO\VPDOO Single Phase Inverter with HD-Wave Technology for North America 6(+866(+866(+866(+86 6(+866(+866(+86 12-25 YEARWARRANTY SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)9999999Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-9 -9 --9 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16-24- -48.5A Power Factor DGMXᐎDEOHWR GFDI Threshold 1 A Utility Monitoring, Islanding 3URWHFWLRQ&RXQWU\&RQÀJXUDEOHThresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9-13.5--27Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity 0D[LPXP,QYHUWHU(੕FLHQF\99 99.2 % &(&:HLJKWHG(੕FLHQF\99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2)$KLJKHUFXUUHQWVRXUFHPD\EHXVHGWKHLQYHUWHUZLOOOLPLWLWVLQSXWFXUUHQWWRWKHYDOXHVᐎDWHG Single Phase Inverterwith HD-Wave Technology for North America 6(+866(+866(+866(+86 6(+866(+866(+86 SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional (3) Inverter Commissioning ZLWKWKH6HW$SSPRELOHDSSOLFDWLRQXVLQJEXLOWLQ:L)LᐎDWLRQIRUORFDOFRQQHFWLRQ Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range µPLQLPXPᐎULQJV$:* µPLQLPXPᐎULQJV$:* Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 OENJ Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)Ü)Ü& Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Revenue grade inverter P/N: SExxxxH-US000BNC4 (4))XOOSRZHUXSWRDWOHDᐎÜ&Ü)IRUSRZHUGHUDWLQJLQIRUPDWLRQUHIHUWRKWWSVZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVVHWHPSHUDWXUHGHUDWLQJQRWHQDSGI Single Phase Inverterwith HD-Wave Technology for North America 6(+866(+866(+866(+86 6(+866(+866(+86 Œ6RODU(GJH7HFKQRORJLHV,QF$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF$OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH TESLA.COM/ENERGY Backup Gateway 2 POWERWALL 660 411 149 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption, time-based control, and backup. The Backup Gateway 2 controls connection to the grid, automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker, the Backup Gateway 2 can be installed at the service entrance. When the optional internal panelboard is installed, the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall, allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Operating Humidity (RH)Up to 100%, condensing Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240V Feed-In Type Split Phase Grid Frequency 60 Hz Current Rating 200 A Maximum Input Short Circuit Current 10 kA1 Overcurrent Protection Device 100-200A; Service Entrance Rated1 Overvoltage Category Category IV AC Meter Revenue accurate (+/– 0.2 %) Primary Connectivity Ethernet, Wi-Fi Secondary Connectivity Cellular (3G, LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self-consumption, time-based control, backup, and off-grid Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC-coupled Powerwalls Optional Internal Panelboard 200A 6-space / 12 circuit Eaton BR Circuit Breakers Warranty 10 years COMPLIANCE INFORMATION Certifications UL 67, UL 869A, UL 916, UL 1741 PCS CSA 22.2 0.19, CSA 22.2 205 Emissions FCC Part 15, ICES 003 NA 2020-05-23 1 When protected by Class J fuses, Backup Gateway 2 is suitable for use in circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2; cellular should not be used as the primary mode of connectivity. Cellular connectivity subject to network operator service coverage and signal strength. MECHANICAL SPECIFICATIONS Dimensions 660 mm x 411 mm x 149 mm (26 in x 16 in x 6 in) Weight 20.4 kg (45 lb) Mounting options Wall mount, Semi-flush mount YIELD SECURITY ANTI PID TECHNOLOGY(APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.QTM) ANTI LID TECHNOLOGY(ALT) Product and Performance Warranty Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID and Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. ZEP COMPATIBLETM FRAME DESIGN High-tech black Zep CompatibleTM frame, for improved aesthetics, easy installation and increased safety. A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information THE IDEAL SOLUTION FOR: Rooftop arrays on commercial and industrial buildings Q.PEAK DUO BLK-G6+ / SC 330-345 ENDURING HIGH PERFORMANCE Į [% / K] + 0.04 ȕ [% / K] − 0.27 Ȗ [% / K] − 0.36 NMOT [°F] 109 ± 5.4 (43 ± 3 °C) 330 335 340 345 [W] 330 335 340 345 [A] 10.41 10.47 10.52 10.58 [V] 40.15 40.41 40.66 40.92 [A] 9.91 9.97 10.02 10.07 [V] 33.29 33.62 33.94 34.25 [%] ≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W] 247.0 250.7 254.5 258.2 [A] 8.39 8.43 8.48 8.52 [V] 37.86 38.10 38.34 38.59 [A] 7.80 7.84 7.89 7.93 [V] 31.66 31.97 32.27 32.57 [V] 1000 (IEC) / 1000 (UL)II [A DC] 20 C (IEC) / TYPE 2 (UL) [lbs / ft2] 50 (2400 Pa) / 50 (2400 Pa)− 40 °F up to + 185 °F (− 40 °C up to + 85 °C)[lbs / ft2] 75 (3600 Pa) / 75 (3600 Pa) 3 See Installation Manual CertifiedUL 1703(254141) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us MECHANICAL SPECIFICATION Format 68.5 × 40.6 × 1.57 in (including frame) (1740 × 1030 × 40 mm) Weight 47.4 lbs (21.5 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 × 1.26-2.36 × 0.59-0.71 in (53-101 × 32-60 × 15-18 mm), Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 43.3 in (1100 mm), (−) ≥ 43.3 in (1100 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G6+/SC_330-345_2019-11_Rev01_NAELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 Ș MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Normal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS Protection Class Maximum Series Fuse Rating Fire Rating based on ANSI / UL 1703 Max. Design Load, Push / Pull (UL)3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull (UL)3 QUALIFICATIONS AND CERTIFICATES UL 1703, CE-compliant, IEC 61215:2016, IEC 61730:2016, Application Class II, U.S. Patent No. 9,893,215 (solar cells) 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²]RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]100 95 90 85 80 75 1552520010 YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 37.4" (950 mm) 68.5" (1740 mm) 4 × Fastening points (DETAIL A) Frame 6.06" (154 mm) 40.55" (1030 mm) 38.6" (981 mm) 1.57" (40 mm) 8 × Drainage opening 0.14" × 3.1" (3.6 mm × 8 mm) 6 × Grounding points ø 0.16" (4 mm) Label DETAIL A 0,472" (12 mm) 0.354" (9 mm)1.063" (27 mm) 15.6“ (395 mm) 7.09" (180 mm) 4 × Drainage opening ≥ 43.3" (1100 mm) ≥ 43. 3" (1100 mm)