Loading...
Stamped PV Plans v4 - Powers, MylesSHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-1F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING 12/17/201 PHOTOVOLTAIC SYSTEMPV SYSTEM SUMMARY: 13.050 KWSITE LOCATION:HOUSE AERIAL VIEW:SITE LOCATION ANDHOUSE AERIAL VIEWROOF MOUNT RESIDENTIAL PHOTOVOLTAIC SYSTEMSYSTEM SIZE (DC): STC: 45 X 290.00= 13050W DC: PTC: 45 X 266.10 = 11974.50W DCSYSTEM SIZE (AC):10000W AC @ 240VMODULES:45 X HANWHA QCELLS: Q.PLUS BFR-G4.1 290, 290WOPTIMIZERS: 45 X SOLAR EDGE: P340INVERTER:SOLAREDGE: SE10000H-USRGM [SI1]ROOF: COMPOSITION SHINGLETILT:22° PITCHAZIMUTH:100° & 280°RAFTER/TRUSS SIZE :2"X6" RAFTERS @ 16" O.C.ATTACHMENT TYPE :UNIRAC: FLASHKIT PRO WITH UNIRAC SM LIGHTRAILMAIN SERVICE PANEL :EXISTING 200 AMPS MSP WITH 200 AMPS MAINBREAKER ON END FEEDINTERCONNECTION : LINE SIDE TAPOCPD RATING: 60 AMPSUTILITY: NATIONAL GRIDTABLE OF CONTENTSPV-1 SITE LOCATION AND HOUSE AERIAL VIEWPV-2SITE PLANPV-2A ROOF PLAN WITH MODULES LAYOUTPV-3ROOF MOUNTING DETAILSPV-4 ELECTRICAL LINE DIAGRAMPV-5EXISTING SERVICE PANELPV-6NOTES AND EQUIPMENT LISTPV-7 LABELSPV-8 OPTIMIZER CHARTPV-9 SAFETY PLANMODULE LOCATIONCITY NOTES:·PV WIRE SHALL BE USED ON DC RUNS FOR UNGROUNDED/TRANSFORMERLESSINVERTERS.·INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK.·EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS·DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETYPRIOR TO ANY EXCAVATION TAKING PLACETHIS PROJECT COMPLIES WITH THE FOLLOWING:2015 INTERNATIONAL BUILDING CODE (IBC) W/780CMR2015 INTERNATIONAL RESIDENTIAL CODE (IRC) W/780 CMR2018 INTERNATIONAL MECHANICAL CODE (IMC)2018 INTERNATIONAL PLUMBING CODE (IPC)2018 INTERNATIONAL FUEL GAS CODE (IFGC)2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)2015 INTERNATIONAL EXISTING BUILDING CODE (IEBC) W/780 CMR2018 INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC)2020 NATIONAL ELECTRICAL CODE (NEC)AS ADOPTED BY TOWN OF EASTHAMPTONCONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS.ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE.INSTALLATION NOTES:SITE LOCATION UM AC INV PM MSP JB SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-2F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201SITE PLANSCALE: 1/32" = 1'-0"1(N) 45 HANWHA QCELLS: Q.PLUSBFR-G4.1 290, 290WROOF LINEPROPERTY LINESITE PLANROOF AREA : 1953.05 SQ FTDRIVEWAY(E) MAIN SERVICE PANEL(E) UTILITY METERDRURY LN 258'-1"182'-7"104'-3"123'-6"182'-7"66'-8"66'-8"88'-5"120'-7"(N) SMART PRODUCTION METER UM AC INV PM MSP JB SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-2AF060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201ROOF PLAN WITH MODULES LAYOUTSCALE: 1/8" = 1'-0"1LEGEND:OBSTRUCTIONPIPE VENT(N) 45 HANWHA QCELLS: Q.PLUSBFR-G4.1 290, 290WROOF PLAN WITHMODULES LAYOUTMODULESCONDUITNOTES:1.EMT CONDUIT ATTACHED TOTHE ROOF USING CONDUITMOUNTS2.ATTACHED CLAMPS AT 25%FROM THE EDGE AND 50% FROMTHE CENTER OF THE MODULES3.JUNCTION BOX IS MOUNTED TOTHE RAIL.SETBACKMSP AC JBACDISCONNECTMSPJUNCTIONBOXINVINVERTERPMPRODUCTIONMETERROOF AREA : 1953.05 SQ FTUMUTILITY METERROOF AREA STATEMENTROOFMODULESQTYPITCHAZIMUTHROOF AREAARRAY AREAARRAYCOVERAGE %SYSTEMDISTRIBUTEDWEIGHT12322°100°596.91 SQ FT413.31 SQ FT41.40%2.50 LBS22222°280°596.91 SQ FT395.34 SQ FT(N) SMART PRODUCTION METER SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-3F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING 12/17/201ROOF MOUNTINGDETAILSMOUNTING DETAILSScale: NTSATTACHMENT DETAILScale: NTSPV MODULEUNIRAC SM LIGHT RAILUNIRAC L-FOOTATTACHMENTSUNIRAC FLASHKIT PROPV MODULEUNIRAC SM LIGHT RAIL SOLAR MOUNT RACKINGSYSTEM(E) SINGLE LAYER OFCOMP SHINGLEEXISTING 2"X6"RAFTERS @ 16" O.C.5/16"x3.5" SS LAG BOLTWITH MIN 212" THREADEMBEDMENT, SEALEDPENETRATIONUNIRAC CHANNEL NUTGROUNDING END/MIDCLAMPUNIRAC L-FOOTATTACHMENTSUNIRAC FLASHKIT PRO2"X6" RAFTERS @ 16" O.C.3" MIN.6" MAX.SAMPLE ROOF FRAMING PLANScale: 1/4"-1'-0"UNIRAC SM LIGHT RAILRACKING SYSTEMSOLAR MODULES2"X6" RAFTERS @ 16" O.C.ROOF ATTACHMENT4'NOTE TO INSTALL: STRUCTURAL UPGRADE IS REQUIRED UNDER THE ARRAY WHERE THE ATTACHMENTS HAPPEN. SEE STRUCTURAL UPGRADE SHEET FOR DETAILS. 2x6 SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-4F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201ELECTRICALLINE DIAGRAM- CONNECT TO PREMISES GEC SYSTEMSTRING-315 HANWHA QCELLS: Q.PLUSBFR-G4.1 290, 290WJUNCTIONBOX2 - #10 AWG, PV WIRE1 - #6 AWG IN FREE AIR OR#8 AWG MUST BE IN EMTCONDUITSTRING-115 HANWHA QCELLS: Q.PLUSBFR-G4.1 290, 290WSTRING-215 HANWHA QCELLS: Q.PLUSBFR-G4.1 290, 290WSOLAREDGE P340POWER OPTIMIZERSSOLAREDGE P340POWER OPTIMIZERS4 - #10 AWG,PV WIREUM(E) 200A / 2PMAIN BREAKER(END FED)(E) 200A RATEDMAIN SERVICE PANEL1PH, 120/240V 60HZ(E) UTILITYMETER(N) NEMA 3RRATED LOCKABLEJUNCTION BOX(N) LINESIDE TAPVIA UL LISTEDCONNECTORS3 - #6 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" OR LARGER EMT CONDUIT(N) MILBANK U5929-XL-INSSINGLE PHASE NEMA 3R600V/100A FORM 2S SMARTPRODUCTION METER(N) 60A RATEDAC DISCONNECTSQUARE D:D222NRB2 - 60 AMPFUSESFUSES SIZINGMAX. CONTINUOUS OUTPUT 42.0A @ 240V42.0X1.25=52.50AMPS60A FUSES - OKPV SYSTEM13.050 kW-DC10.000 kW-ACNOTE:CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASEDON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS(N) INVERTERSOLAREDGE:SE10000H-USRGM [SI1]6 - #10 AWG, THWN-21 - #8 EGC, THWN-2IN 3/4" ORLARGER EMT CONDUITCONDUCTOR AMPACITY DE-RATE CALCULATIONWireLocationCONDUCTORQUANTITYCircuitConductor SizeNEC Factors Table310.15(B)(16)Allowable AmpacityNEC Factors Table310.15(B)(2)(a)AmbientTemperatureCorrectionAdj. ConductorAmpacity @ 90°CConduit FillCorrection Per310.15(B)(3)(a)INVERTER TOAC DISCONNECTWALL36751.0075.001.00AC DISCONNECTTO POIWALL36751.0075.001.00RAPIDSHUTDOWNSWITCH SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-5F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201EXISTINGSERVICE PANEL SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-6F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201NOTES ANDEQUIPMENT LISTMATERIAL LIST1SOLAREDGE:SE10000H-USRGM [SI1]45SOLAR EDGEP340 POWEROPTIMIZERSQTYEQUIPMENTDESCRIPTION45HANWHAQCELLS: Q.PLUSBFR-G4.1 290,290W39.48V32.29V9.52A8.98A266.1WOPEN CIRCUIT VOLTAGE (Voc) :MAX. POWER VOLTAGE (Vmp) :SHORT CIRCUIT CURRENT (Isc) :MAX. POWER CURRENT (Imp) :PTC RATING :DC MAX SYSTEM VOLTAGE :AC OUTPUT VOLTAGE RANGE :MAX. AC OUTPUT CURRENT :MAX. AC POWER OUPUT :WEIGHTED EFFICIENCY :480V211-240V42.0A10000W99%GENERAL NOTES :1.(45) HANWHA QCELLS: Q.PLUS BFR-G4.1 290, 290W WIRED AND LISTED TO UL1703 STANDARDS2.THE SOLAREDGE: SE10000H-USRGM [SI1] INVERTER WITH INTEGRATED DC DISCONNECT AND ARC FAULT PROTECTION.ATTACHED WITH SYSTEM ELECTRICAL SPECIFICATIONS, GROUND FAULT PROTECTION & LISTED TO UL 1741STANDARDS.3.PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE AS PER NEC SEC.250.166(A).4.SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690OF THE NEC5.CONDUIT ABOVE ROOF SHALL BE NO LESS THAN 1" FROM TOP OF THE ROOF TO BOTTOM OF RACEWAY. TABLE NEC310.15(B)(3)(C)6.PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN METALLIC RACEWAY AND SHALL BEIDENTIFIED EVERY 10 FEET -- AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS, OR BARRIERS -- WITH MINIMUM 3/8-INCH-HIGH WHITE LETTERING ON RED BACKGROUNDREADING: “WARNING: PHOTOVOLTAIC POWER SOURCE"7.SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THE REQUIREMENTS OF NECTABLE 250.66.8.THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER.9.UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM.10.TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION.11.SOLAREDGE INVERTERS ARE LISTED TO UL 1741 AND UL 1699B STANDARDS.12.SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS.RATED DC INPUT POWER :MAXIMUM INPUT VOLTAGE :MPPT RANGE :MAX. INPUT CURRENT :MAX. OUTPUT CURRENT :340W48VDC8-48VDC13.75ADC15ADC2FUSES60A FUSES1JUNCTION BOX600VDC, NEMA 3R, UL LISTED1AC DISCONNECT 60A RATED, 240VAC, NEMA 3RUL LISTED108ATTACHMENTSUNIRAC: FLASHKIT PRO540 FtRAILUNIRAC SM LIGHT RAIL72MID CLAMPSUNIRAC SM LIGHT RAILGROUNDING MID CLAMPS36END CLAMPSUNIRAC SM LIGHT RAIL ENDCLAMPS100 FTCONDUIT 3/4" OR LARGER EMT CONDUIT UM AC INV PM MSP JB SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-7F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201JUNCTION BOX 45 PV MODULELABELSCAUTION:POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THEFOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN.DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMESNOTES:1.NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGSSHOWN HEREON2. ALL MARKING SHALL CONSIST OF THE FOLLOWING:A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED ORMACHINE PRINTED LETTERS OR ELECTRO-PLATING.B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK.C.AERIAL FONT.3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED INTHE LOCATIONS SPECIFIED. SIGNAGE CANNOT BEHAND-WRITTEN.4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITHPOP-RIVETS OR SCREWS.DRURY LN6X8" TYP - NEC 705.10ARRAYMACINVERTERJ/BDCEVERY 10' ON CONDUIT AND ENCLOSURESTURN RAPID SHUTDOWNSWITCH TO THE "OFF"POSITION TO SHUTDOWN PV SYSTEM ANDREDUCE SHOCKHAZARD IN THE ARRAY"WARNING"ELECTRICAL SHOCK HAZARD.TERMINALS ON BOTH LINE AND LOAD SIDESMAY BE ENERGIZED IN THE OPEN POSITION690.54 690.15, 690.54690.13 (B)690.53PV SYSTEM DC DISCONNECTMAXIMUM VOLTAGE: 480VMAXIMUM CIRCUIT CURRENT: 42.0AMAX RATED OUTPUT CURRENT OFTHE CONTROLLER OR DC-TO-DCCONVERTER: 15A690.56(C)(1)(A)RAPID SHUTDOWN SWITCH FORSOLAR PV SYSTEM690.56(C)(3)SOLAR PV SYSTEM EQUIPPED WITHRAPID SHUTDOWNSOLAR ELECTRICPV PANELSNEC 690.31(G)(3) & (4)705.12(B)(2)(3)(b)"WARNING"DUAL POWER SOURCESSECOND SOURCE IS PHOTO- VOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 42.0 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSPV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 42.0 AMPSAC NORMAL OPERATING VOLTAGE - 240 VOLTSWARNING:POWER SOURCE OUTPUTCONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICE"WARNING"PHOTOVOLTAIC POWER SOURCEAC DISCONNECTPRODUCTION METERINVERTER EQUIPPEDWITH RAPID SHUTDOWNUTILITY METERMAIN SERVICE PANEL SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-8F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201OPTIMIZERCHART123456789101-1011-2021-3031-4041-5051-60SOLAREDGE OPTIMIZER CHART SHEET:TITLE:CLIENT:REVISIONS:DATE:DESIGNBY:JOB NO.:DESCRIPTIONDATEREVISIONPOWERS, MYLES218 DRURY LN,EASTHAMPTON, MA 01027413-695-15579/16/20GREGPV-9F060986Electrical Contractor No:HIC 198080902-EL-A1MATTHEW MARKHAMFREEDOM FOREVER MASSACHUSETTS35 Robert Treat Paine Dr. Tauton, MA 02780Tel: (800) 385-1075UPDATE RAFTER SPACING12/17/201SAFETYPLANCREW SIGNATURES:MEDICAL INFORMATION:PPE INFORMATIONHAZARDSSAFETY PLANSCALE: NTS1 Q.PLUS BFR-G4.1 280-2901 APT test conditions: Cells at -1500 V against grounded, with conductive me-tal foil covered module surface, 25 °C, 168 h2 See data sheet on rear for further information.Q.ANTUM SOLAR MODULEThe new high-performance module Q.PLUS BFR-G4.1 is the ideal solution for all applications thanks to its innovative cell technology Q.ANTUM. The world-record cell design was developed to achieve the best performance under real conditions – even with low radiation intensity and on clear, hot summer days. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 17.7 %.INNOVATIVE ALL-WEATHER TECHNOLOGYOptimal yields, whatever the weather with excellent low-light and temperature behavior.ENDURING HIGH PERFORMANCELong-term yield security with Anti-PID Technology1,Hot-Spot-Protect and Traceable Quality Tra.Q™.EXTREME WEATHER RATINGHigh-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa) regarding IEC.MAXIMUM COST REDUCTIONSUp to 10 % lower logistics costs due to higher module capacity per box.A RELIABLE INVESTMENTInclusive 12-year product warranty and 25-year linear performance guarantee2. THE IDEAL SOLUTION FOR:Rooftop arrays on commercial / industrial buildingsRooftop arrays onresidential buildingsANTI PID TECHNOLOGY(APT)HOT-SPOT PROTECT(HSP)TRACEABLE QUALITY(TRA.Q™)YIELD SECURITY174 modules testedBest polycrystallinesolar module 2014Q.PRO-G2 235MOD:27898photon.info/laboratory999Quality TestedID. 40032587high reliabilitylow degradationfrequentproduct surveillanceUL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2); IEC 61730 (Ed.1) application class ASpecifications subject to technical changes © Hanwha Q CELLS Q.PLUS BFR-G4.1_280-290_2016-08_Rev01_NAAt least 97 % of nominal power during first year. Thereafter max. 0.6 % degradation per year.At least 92 % of nominal power up to 10 years.At least 83 % of nominal power up to 25 years.All data within measurement tolerances.Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country.Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Hanwha Q CELLS America Inc.300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.usMECHANICAL SPECIFICATIONQ CELLS PERFORMANCE WARRANTYPERFORMANCE AT LOW IRRADIANCEIRRADIANCE [W/m²]RELATIVE EFFICIENCY [%] 200400600800 10001101009080Format65.7 in × 39.4 in × 1.26 in (including frame)(1670 mm × 1000 mm × 32 mm)Weight41.45 lbs (18.8 kg)Front Cover0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technologyBack CoverComposite filmFrameBlack anodized aluminumCell6 × 10 Q.ANTUM solar cellsJunction box3.54-4.33 in × 2.99-3.03 in × 0.59-0.75 in (90-110 × 76-77 × 15-19 mm),Protection class IP67, with bypass diodesCable4 mm² Solar cable; (+) ≥ 39.37 in (1000 mm), (-) ≥ 39.37 in (1000 mm)ConnectorMC4, IP68PROPERTIES FOR SYSTEM DESIGNMaximum System Voltage VSYS[V]1000 (IEC) / 1000 (UL)Safety ClassIIMaximum Series Fuse Rating[A DC]20Fire RatingC (IEC) / TYPE 1 (UL)Design load, push (UL)2[lbs/ft2]75 (3600 Pa)Permitted module temperatureon continuous duty− 40 °F up to +185 °F(− 40 °C up to +85 °C)Design load, pull (UL)2[lbs/ft2]55.6 (2666 Pa)2 see installation manualQUALIFICATIONS AND CERTIFICATESPACKAGING INFORMATIONNumber of Modules per Pallet32Number of Pallets per 53' Container30Number of Pallets per 40' Container26Pallet Dimensions ( L × W × H )68.7 in × 45.3 in × 46.1 in(1745 × 1150 × 1170 mm)Pallet Weight1435 lbs (651 kg)NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product.RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]10095908580751552520010YEARS97Q CELLSIndustry standard for tiered warranties*Industry standard for linear warranties**Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014)DETAIL A0.630" (16 mm)0.335" (8.5 mm)0.965" (24.5 mm)Junction bo×Product label38.58" (980 mm)65.7" (1670 mm) 4 × Fastening points (DETAIL A)Cable withconnectorsFrame5.90" (150 mm)39.4" (1000 mm)37.44" (951 mm)1.26" (32 mm)8 × Drainage holes6 × Grounding points ø 0.177" (4.5 mm)39.37" (1000 mm)13.6“ (345 mm)ELECTRICAL CHARACTERISTICSPOWER CLASS280 285 290MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / -0 W)MinimumPower at MPP2PMPP[W]280 285 290Short Circuit Current*ISC[A]9.41 9.46 9.52Open Circuit Voltage*VOC[V]38.97 39.22 39.48Current at MPP*IMPP[A]8.84 8.91 8.98Voltage at MPP*VMPP[V]31.67 31.99 32.29Efficiency2Ș[%]≥ 16.8≥ 17.1 ≥ 17.4MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3MinimumPower at MPP2PMPP[W]207.0 210.7 214.4Short Circuit Current*ISC[A]7.58 7.63 7.68Open Circuit Voltage*VOC[V]36.37 36.61 36.84Current at MPP*IMPP[A]6.93 6.99 7.05Voltage at MPP*VMPP[V]29.87 30.15 30.4211000 W/m², 25 °C, spectrum AM 1.5 G 2 Measurement tolerances STC ± 3 %; NOC ± 5 % 3 800 W/m², NOCT, spectrum AM 1.5 G * typical values, actual values may differCertifiedUL 1703(254141)TEMPERATURE COEFFICIENTSTemperature Coefficient of ISCĮ[% / K]+ 0.04Temperature Coefficient of VOCȕ[% / K]− 0.29Temperature Coefficient of PMPPȖ[% / K]− 0.40Normal Operating Cell TemperatureNOCT [°F]113 ± 5.4 (45 ± 3 °C) DQD 507 Rev. 2016-02-18 Page 1 Certificate of Compliance Certificate: 70131735 Master Contract: 266909 (266909) Project: 70185553 Date Issued: 2018-10-08 Issued to: Unirac 1411 Broadway NE Albuquerque, New Mexico 87102 USA Attention: Klaus Nicolaedis The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Michael Hoffnagle Michael Hoffnagle PRODUCTS CLASS - C531302 - POWER SUPPLIES- PHOTOVOLTAICS--PV Racking CLASS - C531382 - POWER SUPPLIES- PHOTOVOLTAICS-PV Racking and clamping systems-Certified to US Standards Models: SM SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV racking system that is installed parallel to the roof in landscape or portrait orientations. ULA Unirac Large Array is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. SOLARMOUNT The system listed is designed to provide bonding/grounding, and mechanical stability for photovoltaic modules. The system is secured to the roof with the L-Foot components through the roofing material to building structure. Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end clamps. The modules are bonded to the racking system with the stainless steel bonding mid clamps with piercing points. The system is grounded with 10 AWG copper wire to bonding/grounding lugs. Fire ratings of Class A with Type 1, 2, 3, or 10 for steep slope. Tested at 5” interstitial gap which allows installation at any stand-off height. Certificate: 70131735 Project: 70185553 Master Contract: 266909 Date Issued: 2018-10-08 DQD 507 Rev. 2016-02-18 Page 2 The grounding of the system is intended to comply with the latest edition of the National Electrical Code, to include NEC 250 & 690. Local codes compliance is required, in addition to national codes. All grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used during the certification testing for the current edition of the project report. The system may employ optimizers/micro-inverters and used for grounding when installed per installation instructions. Mechanical ratings: Downward Design Load (lb/ft²) 113.4 Upward Design Load (lb/ft²) 50.4 Down-Slope Load (lb/ft²) 14.7 Conditions of acceptability: Installation is subject to acceptance of the local inspection authorities having jurisdiction. The certification of these products relates only to the methods of installation, bonding, and grounding as outlined in the Installation Manual for each product. Unirac Large Array ULA is a ground mount system using the SolarMount (SM) platform for the bonding and grounding of PV modules. ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the horizontal Pipe to the vertical Pipe. The Front cap is also used to secure the Cross brace. A Slider is attached to the vertical Pipe to secure the Cross brace. The SM rails, caps, slider, rail brackets, and cross braces materials are 6105-T5 aluminum extrusion. Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials meet the minimum requirements of ASTM A53 for galvanized steel pipe in 2” and 3” diameter. The mechanical load ratings from the SM test data will be applied to the ULA model. Fire Testing is not applicable due to being a ground mount system. APPLICABLE REQUIREMENTS UL 2703-1st Edition - Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. LTR AE-001-2012 - List of Technical Requirements for Photovoltaic Module and Panel racking Systems MARKINGS The manufacturer is required to apply the following markings: x Products shall be marked with the markings specified by the particular product standard. x Products certified for Canada shall have all Caution and Warning markings in both English and French. Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 1 of 3 GFT-OP-10a Subject: ETL Evaluation of SolarEdge Products to NEC 2017 Rapid Shutdown Requirements To, whom it may concern This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2017, Section 690.12 requirement for rapid shutdown. UL 1741, UL 1741 CRD for rapid shutdown The evaluation was done on the PV Rapid Shutdown System (PVRSS), and covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to: x Not more than 30 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation outside the array. x Not more than 80 volts and 240 voltamperes within 30 seconds of rapid shutdown initiation inside the array. The rapid shutdown initiation is performed by either disconnecting the AC feed to the inverter, or – if the inverter DC Safety switch is readily accessible – by turning off the DC Safety switch. Applicable products: x Power optimizers: o PB followed by 001 to 350; followed by -AOB or -TFI. OP followed by 001 to 500; followed by -LV, -MV, -IV or -EV. P followed by 001 to 850. SP followed by 001 to 350. *When optimizers are connected to 2 or more modules in series, the max input voltage may exceed 80V. Following the implementation of the NEC 2017 rapid shutdown value of 80V max inside of the array at the beginning of 2019 , modules exceeding this combined input max voltage will be required to use optimizers with parallel inputs. x 1-ph Inverters: Address: Intertek 3933 US 11 Cortland NY 13045 Telephone: 607-758-6516 www.intertek.com This information is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense, or damage occasioned by the use of this information. Any observations and results in this report are relevant only to the sample evaluated. Only the Client is authorized to copy and distribute this information and only then in its entirety. © 2018 Intertek Version: 8-September-2016 Page 2 of 3 GFT-OP-10a o SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE10000A-US / SE11400A-US / SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix x 3-ph Inverters: o SE9KUS / SE10KUS / SE14.4KUS / SE20KUS / SE30KUS / SE33.3KUS /SE43.2KUS / SE66.6KUS / SE100KUS ; when the following label is labeled on the side of the inverter: Inverter part number may be followed by a suffix If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. TÜV Rheinland PTL, LLC, 1107 W. Fairmont Drive, Building A, Tempe, Arizona 85282, Tel (480) 966-1700, Fax (775) 314-6458