Loading...
The Community Builders-se-p-series-add-on-power-optimizer-datasheetPOWER OPTIMIZERPower Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 solaredge.com PV power optimization at the module level Specifically designed to work with SolarEdge inverters Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Up to 25% more energy Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading Fast installation with a single bolt Flexible system design for maximum space utilization 25 YEARWARRANTY Power Optimizer P370 / P401 / P404 / P405 / P485 / P500 / P505 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 06/2020/V02/ENG ROW. Subject to change without notice. (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed.(2) For other connector types please contact SolarEdge.(3) For dual version for parallel connection of two modules use the P485. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module is supported. When connecting a single module, seal the unused input connectors using the supplied pair of seals. OPTIMIZER MODEL(typical module compatibilty) P370(60/72 Cell modules) P401(For high power 60/72-cell modules) P404(for 60/72-cell short strings) P405(for high-voltagemodules) P485 (for high-voltage modules) P500(for 96-cellmodules) P505(for highercurrentmodules)UNIT INPUT Rated Input DC Power(1)370 400 405 405 485 500 505 W Absolute Maximum Input Voltage(Voc at lowest temperature)60 80 125 80 83 Vdc MPPT Operating Range 8 - 60 12.5 - 80 12.5 - 105 8 - 80 12.5-83 Vdc Maximum Short Circuit Current (Isc)11 11.75 11 10.1 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x29.5 / 5.08 x6.02 x 1.16 129 x 89 x 42.5 / 5.1 x 3.5 x 1.7 129 x 90 x 49.5 / 5.1 x 3.5 x 1.9 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)655 / 1.5 775 / 1.7 845 / 1.9 750 / 1.7 1064 / 2.3 gr / lb Input Connector MC4(2)Single or Dual MC4(2)(3)MC4(2) Input Wire Length 0.16 / 0.52 m / ft Output Connector MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 Relative Humidity 0 - 100 % PV SYSTEM DESIGN USING ASOLAREDGE INVERTER(4)(5) SINGLE PHASEHD-WAVE SINGLE PHASE THREE PHASE THREE PHASE FOR 277/480V GRID Minimum String Length (Power Optimizers) P370, P401, P500(6)8 16 18 P404, P405, P485, P505 6 14 (13 with SE3K(7))14 Maximum String Length (Power Optimizers)25 50 50 Maximum Power per String 5700 5250 11250(8)12750(9)W Parallel Strings of Different Lengths or Orientations Yes (4) It is not allowed to mix P404/P405/P485/P505 with P370/P401/P500/P600/P650/P730/P801/P800p/P850/P950 in one string.(5) For SE15k and above, the minimum DC power should be 11KW. (6) The P370/P401/P500 cannot be used with the SE3K three phase inverter (available in some countries; refer to the three phase inverter SE3K-SE10K datasheet).(7) Exactly 10 when using SE3K-RW010BNN4 (8) For the 230/400V grid: it is allowed to install up to 13,500W per string when the maximum power diference between each string is 2,000W.(9)For the 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power diference between each string is 2,000W