Loading...
The Community Builders-SE9K & SE14.4K se-three-phase-us-inverter-208V-datasheetINVERTERSwww.solaredge.us SolarEdge Three Phase Inverters for the 208V Grid for North America SE9KUS / SE14.4KUS) The best choice for SolarEdge enabled systems Integrated arc fault protection for NEC 2011 690.11 Rapid shutdown for NEC 2014 690.12 Outdoor and indoor installation Built-in module-level monitoring Internet connection through Ethernet or Wireless Small, lightweight and easy to install on provided bracket Fixed voltage inverter, DC/AC conversion only Integrated Safety Switch 12-25 USA ͳ GERMANY ͳ ITALY ͳരFRANCE ͳര:APAN ͳരCHINA ͳരAUSTRALIA ͳ THE NETHERLANDS ͳ UK ͳ ISRAEL © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2016. V.01. Subject to change without notice. Three Phase Inverters for the 208V Grid for North America SE9KUS / SE14.4KUS(1) SE9KUS SE14.4KUS OUTPUT Rated AC Power Output 9000 14400 VA Maximum AC Power Output 9000 14400 VA AC Output Line Connections 4-wire WYE (L1-L2-L3-N) plus PE or 3 wire Delta AC Output Voltage Minimum-Nominal- Maximum(2) (L-N)105-120-132.5 Vac AC Output Voltage Minimum-Nominal- Maximum(2) (L-L)183-208-229 Vac AC Frequency Min-Nom-Max(2)59.3 - 60 - 60.5 Hz Max. Continuous Output Current (per Phase) 25 40 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Set Points Yes INPUT Maximum DC Power (Module STC)12150 19400 W Transformer-less, Ungrounded Yes Maximum Input Voltage DC to Gnd 250 300 Vdc Maximum Input Voltage DC+ to DC-500 600 Vdc Nominal Input Voltage DC to Gnd 200 Vdc Nominal Input Voltage DC+ to DC-400 Vdc Maximum Input Current 26.5 38 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 1MΩ Sensitivity CEC Weighted Effciency 96.5 97 % Night-time Power Consumption < 3 < 4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional) Rapid Shutdown – NEC 2014 690.12 Manual Rapid Shutdown(3)Automatic Rapid Shutdown STANDARD COMPLIANCE Safety UL1741, UL1699B, UL1998, CSA 22.2 Grid Connection Standards IEEE1547 Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4” minimum / 12-6 AWG DC input conduit size / AWG range 3/4” minimum / 12-6 AWG Number of DC inputs 2 pairs 3 pairs (with fuses on plus & minus)(4) Dimensions (HxWxD)21 x 12.5 x 10.5 / 540 x 315 x 260 in/mm Dimensions with Safety Switch (HxWxD)30.5 x 12.5 x 10.5 / 775 x 315 x 260 in/mm Weight 73.2 / 33.2 99.5 / 45 Weight with Safety Switch 79.7 / 36.2 106 / 48 Cooling Fans (user replaceable) Noise < 50 < 55 dBA Operating Temperature Range -40 to +140 / -40 to +60 ˚F/˚C Protection Rating NEMA 3R (1) For 277/480V inverters refer to: http://www.solaredge.com/files/pdfs/products/inverters/se-three-phase-us-inverter-datasheet.pdf(2) For other regional settings please contact SolarEdge support.(3) With installation of rapid shutdown kit; contact SolarEdge for kit P/N.(4) Field replacement kit for 1 pair of inputs P/N: DCD-3PH-1TBK.