Azzoni StructuralTo:ReVision Energy 7 Commercial Drive Brentwood, NH 03833 Subject:Structural Certification for Installation of Solar Panels Azzoni Residence 5 Fort Street Northampton, MA. 01060 To Whom It May Concern, The spacing of the solar standoffs should be kept at 48" o.c. or less with a staggered pattern to ensure proper distribution of loads. I further certify that all applicable loads required by the codes and design criteria listed below were applied to the Ironridge solar rail system and analyzed. Furthermore, the installation crews have been thoroughly trained to install the solar panels based on the specific roof installation instructions developed by Ironridge for the racking system and Ecofasten for the roof connections. Finally, I accept the certifications indicated by the solar panel manufacturer for the ability of the panels to withstand high wind and snow loads. September 23, 2020 A design check for the subject residence was done on the existing roofing and framing systems for the installation of solar panels over the roof. From a field inspection of the property, the existing roof support structures were observed by the client's auditors as follows: The roof structure of (MP1) consists of composition shingle (replacing existing slate tiles) on 1x wood decking. The wood decking is supported by true dimensioned old growth 2x4 rafters at 30" o.c., paired with raised ceiling joists to create a semi-vaulted ceiling. The rafters are butt joined at the peak, and are supported by load bearing walls at the eave. The roof structure of (MP2) consists 2 layers of composition shingle on plywood sheathing. The plywood sheathing is supported by 2x6 rafters at 32" o.c., detected by non destructive probing test. The total horziontal span of the roof is approximately 12'-0", with a load bearing wall at mid roof to provide intermediate support to the rafters. Therefore, the max horizontal span of the 2x6 rafters is 6'-0", with a slope of 19 degrees. The roof structure of (MP3) consists of 1 layer of composition shingle on plywood sheathing that is supported by nominal 2x6 rafters at 16" o.c.. The rafters support a vaulted ceiling and have a max horizontal span of 5'-6", with a slope of 29 degrees. The rafters are connected to a ridge beam at the peak, and are supported by the exterior load bearing wall at the eave. The existing roof framing system of (MP1) is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The existing roof framing system of (MP2) is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The existing roof framing system of (MP3) is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. Azzoni Residence, Northampton 1 Design Criteria: ●Applicable Codes = Massachusetts Residential Code, 9th Edition, ASCE 7-12, and 2015 NDS ●Roof Dead Load = 7 psf (MP1) -- 9 psf (MP2) -- 11 psf (MP3) ●Roof Live Load = 20 psf ●Wind Speed = 117 mph, Exposure B ● Sincerely, Elaine Huang, P.E. Project Engineer Ground Snow Load = 40 psf - Roof Snow Load = 35 psf Please contact me with any further questions or concerns regarding this project. Azzoni Residence, Northampton 2 40 psf (ASCE7 - Eq 7-1) 1 (ASCE7 - Table 7-2) 1.1 (ASCE7 - Table 7-3) 1.1 35.0 psf (ASCE7 - Eq 7-2) 1 35.0 psf 3.00 3.00 0.89 0.00 (Ceiling Not Vaulted)0.117.0 psf 8.4 psf 6.00 2.000.86 0.00 (Ceiling Not Vaulted)0.149.0 psf 9.52 3.00 2.001.72 4.000.2811.0 psf 12.58DL Adjusted to 29 Degree Slope ps = Cspf ps = Sloped Roof Snow Load = pf = Flat Roof Snow Load = Roof Snow Load Calculations pg = Ground Snow Load = Miscellaneous 1x Decking Vaulted Ceiling Ce = Exposure Factor = pf = 0.7 Ce Ct I pg Ct = Thermal Factor = I = Importance Factor = Cs = Slope Factor = Roof Dead Load (MP1) Composition Shingle Roof Dead Load (MP3) Roof Plywood Vaulted Ceiling 2x4 Rafters @ 30"o.c. 2x6 Rafters @ 32"o.c. MiscellaneousTotal Roof DL (MP2) Total Roof DL (MP1) Roof Dead Load (MP2) Composition Shingle DL Adjusted to 34 Degree Slope DL Adjusted to 19 Degree Slope Gravity Loading MiscellaneousTotal Roof DL (MP3) PV Dead Load = 4 psf (Per catalog) Roof Plywood Composition Shingle 2x6 Rafters @ 16"o.c. Vaulted Ceiling Azzoni Residence, Northampton 3 Per ASCE 7-12 Components and Cladding 117 mph BGable/Hip34 degrees 20 ft40 ft 17.5 ft (Eq_30.3-1)0.7 (Table 30.3-1) 1 (Fig. 26.8-1)0.85 (Table 26.6-1) 117 mph 1 (Table 1.5-1)qh = 20.85 Zone 1 Zone 2 Zone 3 Positive GCp =-0.90 -1.10 -1.10 0.85 (Fig. 6-11) Uplift Pressure =-18.77 psf -22.94 psf -22.94 psf 17.7 psf X Standoff Spacing =4.00 4.00 4.00 Y Standoff Spacing =2.75 2.75 2.75 Tributary Area =11.00 11.00 11.00Footing Uplift =-206 lb -252 lb -252 lb -252 lb 400 lbTherefore, OK Fastener =1 - 5/16" dia Lag Number of Fasteners =1 Embedment Depth =2.5Pullout Capacity Per Inch =205 lb NDS Eq 12.2-1) Fastener Capacity =513 lb NDS Eq 11.3-1) w/ F.S. of 1.0 =513 lbTherefore, OK Embedment Depth Reduction Factor 1 Lateral Force From Gravity Loads 215 Attachment Lateral Capacity 288 (NDS Table 12K) Therefore, OK Fastener Uplift Capacity Check Fastener Shear Capacity Check 513 lb capacity > 252 lb demand Input VariablesWind Speed Effective Wind Area Design Wind Pressure Calculations Roof Shape Building Least Width Roof Slope 288 lb capacity > 216 lb demand Wind Calulations Standoff Uplift Capacity =400 lb capacity > 252 lb demand Kz (Exposure Coefficient) = Kzt (topographic factor) = Kd (Wind Directionality Factor) = V (Design Wind Speed) = I Importance Factor = qh = 0.00256 * Kz * Kzt * Kd * V^2 * IWind Pressure P = qh*(G*Cp) Exposure Category Mean Roof Height Standoff Uplift Calculations Standoff Uplift Check Maximum Design Uplift = Azzoni Residence, Northampton 4 PASS Dead Load 8.4 psfPV Load 4.0 psf Snow Load 35.0 psf Governing Load Combo = DL + SLTotal Load 47.4 psf Fb (psi) =f'b x Cd x Cf x Cr (NDS Table 4.3.1)975 x 1.15 x 1.5 x 1.15 Allowed Bending Stress = 1934.1 psi (wL^2) / 8 =726.479 ft# =8717.75 in# Actual Bending Stress = (Maximum Moment) / S = 1634.6 psi L/180 (E = 1500000 psi Per NDS)=0.466 in Deflection Criteria Based on =(5*w*L^4) / (384*E*I)= =L/210 <L/180 Therefore OK Allowed Deflection (Live Load) =L/240 0.35 in(5*w*L^4) / (384*E*I) L/284 <L/240 Therefore OK Member Area =Fv (psi) =150 psi (NDS Table 4A)Allowed Shear = Fv * A /1.5 =Max Shear (V) = w * L / 2 =415 lb Check Bending Stress 2x4 Rafters @ 30"o.c. Member Span = 7' - 0" 8.0 in^2 Check Shear w = 119 plf (True Dimensions) 800 lb Allowed > Actual -- 51.9% Stressed -- Therefore, OK HF#1 Member Spacing@ 30"o.c. Maximum Moment = Check Deflection I (in^4)10.67 Lumber Sp/Gr Actual Deflection (Live Load) = Allowed Deflection (Total Load) = Actual Deflection (Total Load) = Allowed > Actual -- 84.6% Stressed -- Therefore, OK Member Properties Member Size2x4 S (in^3)5.33 Framing Check (MP1) Simple Span 0.401 in 0.296 in Azzoni Residence, Northampton 5 PASS Dead Load 9.5 psfPV Load 4.0 psf Snow Load 35.0 psf Governing Load Combo = DL + SLTotal Load 48.5 psf Fb (psi) =f'b x Cd x Cf x Cr (NDS Table 4.3.1)875 x 1.15 x 1.3 x 1 Allowed Bending Stress = 1308.1 psi (wL^2) / 8 =582.223 ft# =6986.68 in# Actual Bending Stress = (Maximum Moment) / S = 923.9 psi L/180 (E = 1400000 psi Per NDS)=0.4 in Deflection Criteria Based on =(5*w*L^4) / (384*E*I)= =L/554 <L/180 Therefore OK Allowed Deflection (Live Load) =L/240 0.3 in(5*w*L^4) / (384*E*I) L/766 <L/240 Therefore OK Member Area =Fv (psi) =135 psi (NDS Table 4A)Allowed Shear = Fv * A/1.5 =Max Shear (V) = w * L / 2 =388 lb (True Dimensions) w = 129 plf 2x6 Rafters @ 32"o.c. Member Span = 6' - 0" Member Properties Member Size S (in^3)I (in^4)Lumber Sp/Gr Member Spacing2x67.56 20.80 SPF#2 @ 32"o.c. Check Shear 8.3 in^2 743 lb Allowed > Actual -- 52.3% Stressed -- Therefore, OK Check Bending Stress Maximum Moment = Allowed > Actual - 70.7% Stressed -- Therefore, OK Check Deflection Allowed Deflection (Total Load) = Actual Deflection (Total Load) = Actual Deflection (Live Load) = Framing Check (MP2) Simple Span 0.094 in 0.130 in Azzoni Residence, Northampton 6 PASS Dead Load 12.6 psfPV Load 4.0 psf Snow Load 35.0 psf Governing Load Combo = DL + SLTotal Load 51.6 psf Fb (psi) =f'b x Cd x Cf x Cr (NDS Table 4.3.1)875 x 1.15 x 1.3 x 1.15 Allowed Bending Stress = 1504.3 psi (wL^2) / 8 =260.034 ft# =3120.4 in# Actual Bending Stress = (Maximum Moment) / S = 412.7 psi L/180 (E = 1400000 psi Per NDS)=0.366 in Deflection Criteria Based on =(5*w*L^4) / (384*E*I)= =L/1347 <L/180 Therefore OK Allowed Deflection (Live Load) =L/240 0.275 in(5*w*L^4) / (384*E*I) L/1942 <L/240 Therefore OK Member Area =Fv (psi) =135 psi (NDS Table 4A)Allowed Shear = Fv * A/1.5 =Max Shear (V) = w * L / 2 =189 lb w = 69 plf 2x6 Rafters @ 16"o.c. Member Span = 5' - 6" Member Properties Member Size S (in^3)I (in^4)2x6 (True Dimensions) 8.3 in^2 7.56 20.80 SPF#2 @ 16"o.c. Check Bending Stress Maximum Moment = Check Shear 743 lb Allowed > Actual -- 25.5% Stressed -- Therefore, OK Actual Deflection (Live Load) = Lumber Sp/Gr Member Spacing Framing Check (MP3) Simple Span 0.049 in 0.034 in Allowed > Actual - 27.5% Stressed -- Therefore, OK Check Deflection Allowed Deflection (Total Load) = Actual Deflection (Total Load) = Azzoni Residence, Northampton 7