Loading...
solar permitCity of Northampton Building Department 212 Main Street Room 100 Northampton, MA 01060 phone 413-587-1240 Fax 413-587-1272 Department use only Status of Permit: Curb Cut/Driveway Permit ____________________ Sewer/Septic Availability______________________ Water/Well Availability________________________ Two Sets of Structural Plans___________________ Plot/Site Plans_____________ Other Specify__________ APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 - SITE INFORMATION 1.1 Property Address: This section to be completed by office Map _______________ Lot __________________Unit_________ Zone ________________ Overlay District______________ Elm St. District__________________ CB District______________ SECTION 2 - PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: ______________________________________________________ Name (Print) _____________________________________________________ Signature _____________________________________________________ Current Mailing Address: ______________________________________________________ Telephone 2.2 Authorized Agent: ______________________________________________________ Name (Print) ______________________________________________________ Signature ______________________________________________________ Current Mailing Address: ______________________________________________________ Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be completed by permit applicant Official Use Only 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total = (1 + 2 + 3 + 4 + 5)Check Number This Section For Official Use Only Building Permit Number:_______________________________ Date Issued:______________________________________________ Signature: ______________________________________________ Building Commissioner/Inspector of Buildings _______________________________ Date _______________________________________________________________@ ____________ EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) 64 Sovereign WayNorthampton, MA 01062 Ari Kasal 143 Northampton Rd, Amherst, MA 01002 See authorized agent form (413) 695-3266 159 Front Street, Chicopee MA 01013All Energy Solar (Colin Buechel) 413-427-2050 $26,069 $7,448 $33,517 colin.buechel allenergysolar.com Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side Rear L:______ R:______ L:______ R:______ Building Height Bldg. Square Footage % Open Space Footage (Lot area minus bldg & paved parking) % # of Parking Spaces Fill: (volume & Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5- DESCRIPTION OF PROPOSED WORK (check all applicable) New House Addition Replacement Windows 0r Doors Alteration(s) Roofing Accessory Bldg. Demolition New Signs [ ] Decks [ ] Siding [ ] Other [ ] _________________________________________________________________ Brief Description of Proposed Work:________________________________________________________________________________________ Alteration of existing bedroom ______Yes ______ No Adding new bedroom _______ Yes _______ No Attached Narrative Renovating unfinished basement _______ Yes _______No Plans Attached Roll - Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family _________ Two Family _________ Other __________ b. Number of rooms in each family unit:______________ Number of Bathrooms_____________ c. Is there a garage attached? _________ d.Proposed Square footage of new construction._____________________ Dimensions __________________________________ e. Number of stories? ________________________________ f. Method of heating? ________________________________ Fireplaces or Woodstoves ___________ Number of each ______ g. Energy Conservation Compliance. _____________________ Masscheck Energy Compliance form attached? _______________ h. Type of construction _______________ i. Is construction within 100 ft. of wetlands? ______ Yes ______ No. Is construction within 100 yr. floodplain ______Yes _____No j. Depth of basement or cellar floor below finished grade __________________________ k. Will building conform to the Building and Zoning regulations? ________ Yes _______ No . l. Septic Tank _____ City Sewer _______ Private well _______ City water Supply _______ SECTION 7a - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, _______________________________________________________________________________________, as Owner of the subject property hereby authorize ________________________________________________________________________________________________ to act on my behalf, in all matters relative to work authorized by this building permit application. ______________________________________________________________________________________________________________ Signature of Owner Date I, _______________________________________________________________________________________, as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. ______________________________________________________________________________________________________________ Print Name ______________________________________________________________________________________________________________ Signature of Owner/Agent Date Solar PV (flush roof mount) Installation of 28 (360W) solar panels flush-mounted to the roof of the residence. x x x Ari Kasal All Energy Solar, Inc. Please see attached authorized agent form All Energy Solar (Colin Buechel) Colin Buechel 8/17/2020 SECTION 8 - CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Name of License Holder :___________________________________________________________ ___________________________________________________________________________ Address ___________________________________________________________________________ Signature Telephone Not Applicable ! _____________________________________ License Number _____________________________________ Expiration Date 9. Registered Home Improvement Contractor: __________________________________________________________________________ Company Name __________________________________________________________________________ Address _________________________________________________Telephone_________________ _ Not Applicable ! _________________________________ Registration Number _________________________________ Expiration Date SECTION 10- WORKERS’ COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... !No...... ! Scott Fournier 67 Pearl Street, South Hadley, MA 01076 413-658-8604 CS-109847 12/4/2021 All Energy Solar 159 Front Street, Chicopee MA 01013 413-427-2050 175144 4/24/2021 City of Northampton Massachusetts DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ● Municipal Building Northampton, MA 01060 AFFIDAVIT Home Improvement Contractor Law Supplement to Permit Application The Office of Consumer Affairs and Business Regulation ("OCABR") regulates the registration of contractors and subcontractors performing improvements or renovations on detached one to four family homes. Prior to performing work on such homes, a contractor must be registered as a Home Improvement Contractor ("HIC"). M.G.L. Chapter 142A requires that the “reconstruction, alteration, renovation, repair, modernization, conversion, improvement, removal, demolition, or construction of an addition to any pre-existing owner-occupied building containing at least one but not more than four dwelling units….or to structures which are adjacent to such residence or building” be done by registered contractors. Note: If the homeowner has contracted with a corporation or LLC, that entity must be registered. Type of Work:______________________________________________ Est. Cost:__________________ Address of Work:______________________________________________________________________ Date of Permit Application:______________________________________________________________ I hereby certify that: Registration is not required for the following reason(s): ___ Work excluded by law (explain):________________________________________________ ___ Job under $1,000.00 ___ Owner obtaining own permit (explain):___________________________________________ ____Building not owner-occupied ___ Other (specify):______________________________________________________________ OWNERS OBTAINING THEIR OWN PERMIT OR ENTERING INTO CONTRACTS WITH UNREGISTERED CONTRACTORS OR SUBCONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK ARE NOT ELIGIBLE FOR AND DO NOT HAVE ACCESS TO THE ARBITRATION PROGRAM OR GUARANTY FUND UNDER M.G.L. Chapter 142A. SUCH OWNERS ALSO ASSUME THE RESPONSIBILITES FOR ALL WORK PERFORMED UNDER THE BUILDING PERMIT. SEE NEXT PAGE FOR MORE INFORMATION. Signed under the penalties of perjury: I hereby apply for a building permit as the agent of the owner: Date Contractor Name HIC Registration No. OR: Notwithstanding the above notice, I hereby apply for a building permit as the owner of the above property: Date Owner Name and Signature Solar PV $26,069 64 Sovereign Way, Northampton, MA 01062 8/17/2020 8/17/2020 All Energy Solar 175144 City of Northampton Massachusetts DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ● Municipal Building Northampton, MA 01060 Massachusetts Residential Building Code Section 110.R5.1.2 Homeowner: Person (s) who own a parcel of land on which he/she resides or intends to reside, on which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in a two-year period shall not be considered a homeowner. Section 110.R5.1.3.1 Any homeowner performing work for which a building permit is required shall be exempt from the licensing provisions of 780 CMR 110.R5, provided that if a homeowner engages a person(s) for hire to do such work, then such homeowner shall act as supervisor. Such homeowner shall submit to the Building Official, on a form acceptable to the Building Official, that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time, during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152 (Workers’ Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death) of the Massachusetts General Laws Annotated, you may be liable for person(s) you hire to perform work for you under this permit. City of Northampton Massachusetts DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ● Municipal Building Northampton, MA 01060 In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: (Please print house number and street name) Is to be disposed of at: (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: (Company Name and Address) Signature of Permit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. Debris Disposal Affidavit 64 Sovereign Way AES 159 Front Street, Chicopee, MA 01013 8/17/2020 64 Sovereign Way Northampton, MA 01062 8/17/2020 10/1/2020 150 C66721176 Lockton Companies, LLC 17 Deborah St ARC Design 409 N. Main Street Elmer, NJ 08318 (856) 712-2166 fax: (856) 358-1511 Date: August 13, 2020 Re: Structural Roof Certification Subj: Kasal Residence, 64 Sovereign Way, Northampton, MA 01062 We have provided a review of the house roof construction of the above named property in regards to verifying the capacity of the existing roof for installation of a new Solar Panel Array. We have found the residence roof to be of wood frame construction bearing walls. Roof 1 is of 2x12 @ 16” o.c. framed roof with 2x8 collar ties @ 16” o.c. and is sheathed with ½” ext. ply decking and a single layer of composite shingle roofing. Roof 2 is of 2x10 @ 16” o.c. framed roof with 2x8 collar ties @ 16” o.c. and is sheathed with ½” ext. ply decking and a single layer of composite shingle roofing. The wood framed roof structure bears directly upon the framed exterior wall system. The existing rafters as installed meet the required (MA 780 CMR) IRC-2015 design span ratings with sufficient capacity to carry the 3#/sf additional load imposed by the proposed solar array per the details below. Installation of solar rack systems shall be as follows: Each panel row shall be supported upon 2 mounting rails. Rails shall be screw anchored through roof and directly to rafters below. Rail attachment points to rafters shall be staggered each row with exception to the first fastener row from the gable end which is attached to two adjacent rafters. A roofing compatible sealant or shingle flashing kit shall be utilized at each mtg. foot location. Solar panel mounting systems installed parallel to the plane of a roof shall be no more than 12" above the roof when measured perpendicular to the roof surface. When installed per the above specifications the system shall meet the required 117 MPH wind load and 40 PSF ground snow load requirements. Should you have any further question or comment please feel free to contact our office. Respectfully, James A. Clancy Professional Engineer MA License # 46775 7/27/2020 Scott Fournier CSL License.jpg https://drive.google.com/drive/folders/0B35cnD_M-iLCfjlyMWlEVEVmV1M4UHRjSjNvZ0pCWjIyeWhjWWhXdTJycGV2Vjg4TE9lZWM 1/1 ANY PROPRIETOR/PARTNER/EXECUTIVEOFFICER/MEMBER EXCLUDED? INSR ADDL SUBRLTR INSD WVD PRODUCER CONTACTNAME:FAXPHONE(A/C, No):(A/C, No, Ext): E-MAILADDRESS: INSURER A : INSURED INSURER B : INSURER C : INSURER D : INSURER E : INSURER F : POLICY NUMBER POLICY EFF POLICY EXPTYPE OF INSURANCE LIMITS(MM/DD/YYYY) (MM/DD/YYYY) AUTOMOBILE LIABILITY UMBRELLA LIAB EXCESS LIAB WORKERS COMPENSATIONAND EMPLOYERS' LIABILITY DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) AUTHORIZED REPRESENTATIVE EACH OCCURRENCE $ DAMAGE TO RENTEDCLAIMS-MADE OCCUR $PREMISES (Ea occurrence) MED EXP (Any one person) $ PERSONAL & ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ PRO-POLICY LOC PRODUCTS - COMP/OP AGGJECT OTHER: $ COMBINED SINGLE LIMIT $(Ea accident) ANY AUTO BODILY INJURY (Per person) $ OWNED SCHEDULED BODILY INJURY (Per accident) $AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $AUTOS ONLY AUTOS ONLY (Per accident) $ OCCUR EACH OCCURRENCE CLAIMS-MADE AGGREGATE $ DED RETENTION $ PER OTH-STATUTE ER E.L. EACH ACCIDENT E.L. DISEASE - EA EMPLOYEE $If yes, describe under E.L. DISEASE - POLICY LIMITDESCRIPTION OF OPERATIONS below INSURER(S) AFFORDING COVERAGE NAIC # COMMERCIAL GENERAL LIABILITY Y / N N / A(Mandatory in NH) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED INACCORDANCE WITH THE POLICY PROVISIONS. THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THISCERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZEDREPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement onthis certificate does not confer rights to the certificate holder in lieu of such endorsement(s). COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: CERTIFICATE HOLDER CANCELLATION © 1988-2015 ACORD CORPORATION. All rights reserved.ACORD 25 (2016/03) CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) $ $ $ $ $ The ACORD name and logo are registered marks of ACORD 4/1/2020 All Energy Solar Inc1264 Energy Lane Saint Paul, MN 55108 25127 A 1,000,000 PK202000016768 3/26/2020 3/26/2021 1,000,000 5,000 1,000,000 2,000,000 2,000,000 CAPPED DESIGNAT 2,000,000 1,000,000B 10021056CA 3/26/2020 3/26/2021 5,000,000A UM202000007951 3/26/2020 3/26/2021 5,000,000 10,000 All Energy Solar Inc. 1264 Energy Lane Saint Paul, MN 55108 ALLENER-02 TLEAVENS SF Insurance Group LLC744 Ryan Dr Ste 101Hudson, WI 54016 Sandra Anderson, CISR, CSRM, CPCU sanderson@sfinsurancegroup.com ProSight State Auto Mutual X X X X X X X COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A0 REVISIONS LAST: 08/7/20 MG AZIMUTH NOTES: 1. (1) SOLAREDGE SE10000H-US INVERTER(S) 2. ARRAY 1: 42° TILT, 262° AZIMUTH 3. ARRAY 2: 47° TILT, 172° AZIMUTH 6. ARRAY 3: (Array 3 Tilt)° TILT, (Array 3 Azimuth)° AZIMUTH 7. ARRAY 4: (Array 4 Tilt)° TILT, (Array 4 Azimuth)° AZIMUTH COVER PAGE ARI KASAL 64 SOVEREIGN WAY NORTHAMPTON, MA 01062 PO 38162 N SOVEREIGN WAY ARRAY 1ARRAY 2LG 360 BOB 28 Flush Roof Mount 10.080 Panel Type # of Panels System Size (kW) COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A2 REVISIONS LAST: 08/7/20 MG AZIMUTH ACCOUNT: 94714-52006 PREMISE: METER: 23556042 PROPERTY MAP N ARI KASAL 64 SOVEREIGN WAY NORTHAMPTON, MA 01062 PO 38162 NOTES: 1. (1) SOLAREDGE SE10000H- US INVERTER(S) = 10.00kW AC 2. ARRAY 1: 262° AZIMUTH, 42° TILT (22) LG 360W = 7.92kW 3. ARRAY 2: 172° AZIMUTH, 47° TILT (6) LG 360W = 2.16kW 4. ARRAY 3: (Array 3 Azimuth)° AZIMUTH, (Array 3 Tilt)° TILT ((Array 3 Panel Qty)) LG 360W = (Array 3 kW)kW 5. ARRAY 4: (Array 4 Azimuth)° AZIMUTH, (Array 4 Tilt)° TILT ((Array 4 Panel Qty)) LG 360W = (Array 4 kW)kW ELECTRICAL BOS PROPERTY LINE ARRAY 1 ARRAY 2 COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A3 REVISIONS LAST: 08/7/20 MG NOTES: 1. ELEVATIONS MAY VARY DEPENDING ON GROUND ELEVATION BUT ARE DRAWN TO THE BEST OF OUR ABILITY 2. 2X12 RAFTERS @ 16" OC 32' 6"20' 7"32' 7"16' 10"19' 2"20' 7"32' 5"32' 7"37' 10" 27'11'23' 4"17' 5"5' 7"ELEVATION DRAWINGS ARI KASAL 64 SOVEREIGN WAY NORTHAMPTON, MA 01062 PO 38162 SOUTH ELEVATION WEST ELEVATION COMPANY INFORMATION CLIENT INFORMATION SYSTEM DETAILS PROJECT-PAGE TITLE ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM PAGE NUMBER A4 REVISIONS LAST: 08/7/20 MG MIN MAX SOLAREDGE STRING LENGTH: 120/240V, P300, P320, P370, P400 MODULE WATTS *STRINGING TO BE DETERMINED ON SITE 2X12 RAFTERS @ 16" OC RAIL AND STRINGING DIAGRAM 355 - 375 8 14 AZIMUTH <aCustName(s)> <aCustAddress1> <aCustAddress2> <aCustAddress3> PO <aCustPONumber>N ARI KASAL 64 SOVEREIGN WAY NORTHAMPTON, MA 01062 PO 38162 SNAP-N-RACK FLASHINGMODULE2X12 RAFTERS @ 16" OC (28) LG LG360N1C-V5 MODULES (28) P370 OPTIMIZERS (1) SOLAREDGE SE10000H-US INVERTER(S) STRINGS: (2) STRING(S) OF 14 OPTIMIZERS ((Qty of circuits with the number of inverters optimizers above)) STRING(S) OF (Qty of inverters/optimizers in a circuit/string) OPTIMIZERS ((Qty of circuits with the number of inverters optimizers above)) STRING(S) OF (Qty of inverters/optimizers in a circuit/string) OPTIMIZERS ((Qty of circuits with the number of inverters optimizers above)) STRING(S) OF (Qty of inverters/optimizers in a circuit/string) OPTIMIZERS ((Qty of circuits with the number of inverters optimizers above)) STRING(S) OF (Qty of inverters/optimizers in a circuit/string) OPTIMIZERS SNAP-N-RACK MOUNTING HARDWARE: 1. (62) L-FEET 2. (6) RAIL SPLICES 3. CLAMPS (44) MIDCLAMPS (24) ENDCLAMPS 4. RAIL LENGTHS: (15) 168" RAILS LEGEND: NEGATIVE END: POSITIVE END: ARRAY 1ARRAY 2 snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience SnapNrack Umbrella Sealing Technology • Innovative Flashing Elevates Protection. New fl ashing uses a fully formed raised cone to prevent any potential water from getting into penetration. Feel secure as the fl ashing is one piece and doesn’t rely on multiple parts sealing together. • Mechanical Design Creates a Lifelong Seal. Patented Umbrella technology utilizes unique Umbrella Washer to seal lag bolt, L Foot, and fl ashing and prevent any potential roof leaks. Technology passes UL 2582 Wind Driven Rain Test without a rubber seal, however rubber gasket is included for extra peace of mind. • Single Fastener Eliminates Extra Steps. Utilize one lag bolt with Umbrella Washer to secure the entire mount assembly and fl ashing. No longer necessary to attach a base, then a fl ashing, then a mount as all are secured in one step. • Single Tool Installation. SnapNrack was the fi rst in the industry to develop a complete system that only requires a single tool. That tradition is continued as a ½” socket is still the only tool necessary to secure the mount as well as all other parts of the system. snapnrack.com Featuring New Innovative Flashing Smaller 9”x12” size allows for easier insertion under shingles Alignment markers make it easy to locate pilot holes Rounded corners make for easier insertion & eliminate corner points from folding up Note: Flashing shown in yellow for illustration purposes only. © 2018 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com snapnrack.com Ultra Rail, UR-40 Rail System Spans Wind (mph) 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 190 Snow (psf)0 5 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 120 System Span Key 6 ft Spans 4 ft Spans 2 ft Spans This table was prepared in compliance with applicable engineering codes and standards. Values are based on the following: • ASCE 7-10 • Chapter 30 Wind Loads & Chapter 7 Snow Loads • Roof Slope: 7 - 27 deg • Roof Height: 0 - 30 ft • Exposure: B • Roof Zone: 1 • Module Orientation: Portrait • Module Type: 60 Cell Modules • Roof Type: Comp Industry Leading Spans for a Light Rail Solution Visit SnapNrack.com for detailed span tables and certifi cations. Certifi cations SnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories (UL) and Listed to UL/ANSI Standard 2703 for Mechanical Loading and Fire. Additionally it is listed to UL 2582 for wind-driven rain. Raised Cone Flashing Single Lag Secures Mount to Roof Pre-assembled Ultra Rail L Foot & Clamp Pre-assembled Ultra Rail