Loading...
Obrien-PlansetRELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVINGJURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNAdvancedSolarSolutions39650MallardBassLake,CA93604 PHONE: 559-321-7000EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSED WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE ALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTEDIN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDED AND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJ REQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT NORTH℄RESERVOIR RD ⅊ ⅊ ⅊ ⅊WATER ST℄ DRIVEWAY N/A VB 7.370 KW PV-001 COVER SHEET Obrien, John Steven Silverman 2015 National Grid 2015 74107048 2015 21134A(413) 584-8844 2020 Lilian Wanjiku(413) 584-8844 City Of Northampton jstocker@valleysolar.solar 50507Civil(202) 874-3483swyssling@wysslingconsulting.com R-3 Risk Category II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook DrAlpine, UT 84004 Obrien, John14 Reservoir Rd, Leeds, MA 01053 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 340 Riverside DrValley Solar Florence, MA 01062 Hanwha Q-Cell Q.PEAK DUO-G6 335 Enphase IQ7PLUS-72-2-US (240V) SnapNrack Ultra Rail UR-40 Snapnrack 242-01220 L FootINTEGRATED IN INVERTER 22 22 N/A 45 N/A0 1 (E) COORDINATES: 42.354343, -72.703216 6.620 KW 2 120/240V - 1 14° 163°,343° ROOF COVERING MAX ARRAY HGT. 116 N/AComp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS X-IQ-AM1-240-3 Enphase 100A BUS/100A MAIN BREAKER LINE-SIDE TAP PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS GENERALNOTES:* PROPERACCESSANDWORKINGCLEARANCEAROUND EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE PROVIDEDASPERSECTIONNEC110.26. PVSYSTEMCOMPONENTS;INCLUDINGBUTNOTLIMITED TO,MODULES,INVERTERSANDSOURCECIRCUIT COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV SYSTEMSINCOMPLIANCEWITHNEC690.4AND690.6 ANDALLUL,IEC,IEEECLASSIFICATIONSAS REQUIREMENTS. RAPIDSHUTDOWNNOTES:* PVSYSTEMCIRCUITSINSTALLEDONORINBUILDIDNG SHALLINCLUDEARAPIDSHUTDOWNFUNCTIONTHAT CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE WITH2020NEC690.12(A)-(D) EQUIPMENTLOCATIONS&ELECTRICAL NOTES:* JUNCTIONANDPULLBOXESAREPERMITTEDTOBE INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH NEC690.34. ADDITIONALACDISCONNECT(S)SHALLBEPROVIDED WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SERVICINGDISCONNECT.2020NEC690.15(A) ALLEQUIPMENTSHALLBEINSTALLEDACCESSIBLETO QUALIFIEDPERSONNELINCOMPLIANCEWITHNEC APPLICABLECODES. ALLCOMPONENTSARELISTEDFORTHEIRINTENDED PURPOSEANDRATEDFOROUTDOORUSAGEWHEN APPLICABLE. STRUCTURALANDINSTALLATION NOTES:* RACKINGSYSTEM&PVPANELSMOUNTEDONA ROOFTOPSHALLBELISTEDANDLABELEDINACCORDANCE WITHUL1703ANDSHALLBEINSTALLEDINACCORDANCE WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED THEPRE-ENGINEEREDMAXSPANSOUTLINEDBYTHE RACKINGMANUFACTURESENGINEEROFRECORD. GROUNDINGNOTES:* INUNGROUNDEDSYSTEMSONLYTHEDCCONDUCTORS AREUNGROUNDEDANDREQUIREANEQUIPMENT GROUNDINGCONDUCTOR.ALLMETALELECTRICAL EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUND,INCOMPLIANCEWITHNEC250.134ANDNEC250.136(A). PVEQUIPMENTINCLUDINGMODULEFRAMESANDOTHER METALPARTSSHALLBEGROUNDEDINCOMPLIANCE WITHNEC690.43ANDMINIMUMGROUND CONDUCTORSSIZEDINACCORDANCEWITHNECTABLE 250.122. CONDUCTIVEPARTSOFMODULEFRAMES,MODULE RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN COMPLIANCEWITHNEC250.134ANDNEC250.136(A). UL2703APPROVEDMODULEANDRACKGROUNDING SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S INSTALLATIONMANUAL.IFUL2703APPROVED GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG HOLESPERTHEMANUFACTURER'SINSTALLATION REQUIREMENTS. THEGROUNDINGCONNECTIONTOAMODULESHALLBE ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER MODULE. THEGROUNDINGELECTRODESYSTEMCOMPLIESWITH NEC690.47ANDNEC250.50THROUGHNEC250.106. IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN COMPLIANCEWITHNEC250,NEC690.47ANDAHJ. PVSYSTEMSSHALLBEPROVIDEDWITHDCGROUND- FAULTPROTECTION2020NEC690.41(B) INTERCONNECTION/POCNOTES:* ALLLOAD-SIDEINTERCONNECTIONSAREINCOMPLIANCE WITH2020NEC705.12(B) THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN COMPLIANCEWITHNEC705.12(B)(2)(3)(c) ALLFEEDERTAP(LOADSIDE)INTERCONNECTIONSAREIN COMPLIANCEWITH2020NEC705.12(B)(2)(1) THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL ALSOBESIZEDAPPROPRIATELYASPER2020NEC705.12(B)(2)(3)(b) SUPPLYSIDETAPINTERCONNECTIONSAREIN COMPLIANCEWITHNEC705.12(A)WITHSERVICE ENTRANCECONDUCTORSINCOMPLIANCEWITHNEC 230.42 BACKFEEDINGBREAKERFORINVERTEROUTPUTISEXEMPT FROMADDITIONALFASTENING2020NEC705.12(B)(5) MICROINVERTERBRANCHCIRCUITSSHALLBECONNECTED TOASINGLEOCPDINACCORDANCEWITHTHEIR INSTALLATIONINSTRUCTIONSANDNEC690.9 DISCONNECTSANDOCPDNOTES:* ALLDISCONNECTINGSWITCHESWILLBECONFIGUREDSO THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” (TYPICALLYTHEUPPERTERMINALS) ALLACDISCONNECTSSHALLBELABELED,LOCKABLE,OF VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. ACDISCONNECTSSHALLBEA“KNIFEBLADE”TYPE DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER PERNEC110.28 ADDITIONALACDISCONNECTSSHALLBEPROVIDED WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC DISCONNECT.2020NEC690.15(A) BOTHPOSITIVEANDNEGATIVEPVCONDUCTORSREMAIN UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH 2020NEC690.15(D) ALLOCPDRATINGSANDTYPESSPECIFIEDSHALLBEIN COMPLIANCEWITHNEC690.8,690.9,705.12AND240. BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE UNGROUNDED;BOTHREQUIREOVERCURRENT PROTECTIONINCOMPLIANCEWITHNEC690.9 ARCFAULT(AFCI)DCCIRCUITPROTECTIONISREQUIRED FORALLPVSYSTEMSONORPENETRATINGABUILDING WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR GREATER.ALLDCPVCIRCUITSINSTALLEDINORON BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN COMPLIANCEWITHNEC690.11,UL1699BANDSHALLBE LISTEDANDLABELEDINACCORDANCEWITHUL1699(B). WIRING&CONDUITNOTES:* ALLCONDUITANDCONDUCTORSSHALLBEAPPROVED FORTHEIRINTENDEDPURPOSEINCLUDINGWET LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE MINIMUMCODEREQUIREMENTSANDARENOTLIMITED TOUPSIZING. ALLCONDUCTORSSHALLBESIZEDINCOMPLIANCEWITH NEC690.8,NEC690.7. ALLCONDUCTORSSHALLBEDERATEDASAPPLICABLETO THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT SUNLIGHTINACCORDANCEWITH2020NEC 310.15(B)(3)(4)(c) EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT CIRCUITSSHALLUSECONDUCTORSLISTEDANDIDENTIFIED ASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE2020NEC 690.31(C)(1).PVMODULESWIRELEADSSHALLBELISTED FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE WITH2020NEC690.4(B) PVWIREBLACKWIREMAYBEFIELD-MARKEDWHITEIN COMPLIANCEWITHNEC200.6(A)(6). PVMODULECONDUCTORSLOCATEDUNDERARRAYSWILL BESECUREDINAWORKMANLIKEMANNERIN COMPLIANCEWITHNEC110.12. WATERPROOFING:* ALLNEWROOFTOPPENETRATIONSSHALLBESEALEDAND MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SEALANTANDFLASHINGSWHEREREQUIREDPERCODE ANDGENERALBUILDINGANDROOFINGWORKMANSHIP STANDARDSBYALICENSEDCONTRACTOR. ALLEXTERIORELECTRICALEQUIPMENT,SHALLBENEMA 3RORBETTERRATED.ALLEXTERIORCONDUITAND CONNECTORSSHALLBERATEDFORWETLOCATIONS. *ALLNOTESAREASAPPLICABLETOTHISPROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS PROJECT.N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPN2015 IFC ROOF ACCESS REQUIREMENTS PV SITE LAYOUT LEGEND EXISTING DIMENSIONS ARE APPROX.ONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 RA RA NORTH SECTION 1 SECTION 2 RESERVOIR RD WATER ST THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. A. B. C. AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/8” = 1’0” @ SHEET SIZE A3 1829 SECTION-1 309 23.24% 163 14°SECTION-1 343 14°SECTION-2 116SECTION-2 QTY 22 Hanwha Q-Cell Q.PEAK DUO-G6 335 MODULES QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESS* EXISTING ROOF DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFING COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING * DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP B.ANCHOR SPACING SHOWNIN DETAIL. UNLESS NOTED OTHERWISE PER RACKINGMANUFACTURER CERTIFIEDENGINEERED PRODUCT ANDLOCAL REQUIREMENTS. SEE"TABLE OF DIMENSIONS" EACH SECTION DETAILED FORHORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENTMANUFACTURERS. ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO ROOF RACKING RAIL NORTH11'-5"13'-734" 27'-334"11'-5"SCALE: 1/8” = 1’0” @ SHEET SIZE A3 Rafter-Simple Attic 24" O.C. 2"x6"@ 24" MAX OC Comp Shingle 2.89 PSF QTY 22 Hanwha Q-Cell Q.PEAK DUO-G6 335 MODULES QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 3:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 4’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND 21SCALE: NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODEREQUIREMENTS AT THE TIME IT WAS BUILT. C.STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING ISACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLYDESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL BE NO MORETHAN TWO LAYERS.(SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUTSIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURALDETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES.STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSPER RAILMANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER MAX RAFTER SPANMAX RAFTER SPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILSARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL * IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV 1 D3 D2 D1 D2H1R2R1 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. * IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV 1 D3 D2 D1 D2H1R2R1 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 (E) FRAMING@ 24" O.C. TYPICAL 2'-0"TYP.4'-0"MAX SIMPLE ATTIC / RAFTER - PORTRAIT SIMPLE ATTIC / RAFTER - LANDSCAPE STANCHION DETAIL STANCHION SPACING DETAIL Ultra Rail UR-40 242-01220 L Foot L-Foot Flashing 12" 14° 3" - 6" TYP 10.14" 20.27" 20.52" 6" 12'-8" 12" 14° 3" - 6" TYP 17.12" 34.25" 34.5" 6" 12'-8" 25' Comp Shingle NOT USED 12'-8"12'-8"S-200Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND * DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATIONINSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE: NTS 3 4 SCALE: NTS SCALE: NTSSCALE: NTS ATTACHMENT DETAILSROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSROOF RACKING RAIL ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" EMBEDMENT INTO FRAMING MEMBERS (E) ROOF SHEATHING /DECKING (E) FRAMING MEMBER L-FOOT PV MODULE, BY OTHERS MODULE END CLAMP SNAPNRACK ULTRA RAIL SNAPNRACK COMP UMBRELLA FLASHINGS5/16”-18 X 2-1/4” SS HCS BOLT 1/3" OF TOTAL SPAN MAX 2/3" OF TOTAL SPAN MAX RAIL MANUFACTURERRAIL SPLICE KITSEE "S-100 / TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE.SEE SHEET "S-100" FOR:HORIZONTAL ANCHOR SPAN SPACING. (E) FRAMINGTYPICAL * MODULES SHOWN PORTRAIT IN EXAMPLE DCAND/OR 1/3CANT.MAX COMPONENT +2" FROM SIDEOF MODULE 2" ROOF TOPCONDUIT EXTENSION OF RAIL RAIL OR STRUTCONNECTIONS TO MEETWEIGHT REQ. OF EQUIPMENT DCB * MODULES SHOWN PORTRAIT IN EXAMPLE** RAILING SHOWING IN VERTICAL IN EXAMPLE RIDGE BEAM *R2*R1VERIFY THAT NO DIAGONAL AND/OR VERTICAL ATTIC/FRAMING STRUT MEMBERSARE CUT OR NOTCHED * SEE DETAILS "1-2/S200" TABLE OF DIMENSIONS HOLES ALLOWED ONLY IN MIDDLE HALF OF FRAMING SPAN 1/4 1/4 HOLES ALLOWED ONLY IN MIDDLE THIRDOF FRAMING DEPTH, *R2, AND NO LARGERTHAN *R2/4 IN DIAMETER. MINIMUMSPACING BETWEEN HOLES AT *R2 FRAMING SAG IN INCHES NOTTO EXCEED FRAMING LENGTHIN FEET DIVIDED BY 20 NOTCHES DEEPER THAN 1/4"NOT ALLOWED ALONG TOP ORBOTTOM EDGE OF FRAMING NOTE: WHERE FRAMING IS VISIBLE FROM ATTIC &/OR UNDERSIDE OF ROOF,VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURALDECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. RIDGE SAG IN INCHES NOT TO EXCEED RIDGELENGTH IN FEET DIVIDED BY 20 STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL RAFTER HOLE AND CONSTRUCTION DETAIL S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CALCULATIONSPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STCTEMPERATURE CORRECTEDTEMPERATURE MFR. PMAX TEMPCOEFFICIENT[-0.#%/C] * 100 FORMULA CORRECTEDTEMP.COEFFICIENT MODULE Voc[VDC] TEMPERATURECORRECTEDOPEN CIRCUITVOLTAGE -=*+=*= PV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/THICK PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (SHORT-CIRCUIT POWER)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC AC COMBINER (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) AC SUB-PANEL #2 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS AMPS (Imax) AMPS (Imax) MICRO INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max PV POWER @ MODULE STC WATTS Max INPUT DC VOLTAGE VOLTS DC Max INPUT CURRENT AMPS MODULES PER MICRO INVERTER QTY AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 ALT. ENERGY BACKFEED BREAKER (IF APPL.)AMPS (Imax) Hanwha Q-CellQ.PEAK DUO-G6 33543.7868.5 x 40.55 x 1.2633539.9933.1310.6210.11-0.2820.0 Enphase IQ7PLUS-72-2-US (240V)2902.38 2906015.01 240201.21 EnphaseX-IQ-AM1-240-324012523RN/A26.622 EatonDG222NRB Fusible2406023R40.026.62 EXISTING120/240V Single Phase100100 020 -20 25 -45 -0.28%0.13 1 1.13 39.99 45.19 45.19 1 E-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUITORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 MAXCURRENT690.8 (A)(1) CONT.OPERATION690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT.TEMP. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILLDERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY DC1 XXX=XX=<WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3. WIRE COLOR CODING (2020) CEC/NEC SECTIONS 250.119 & 200.6 PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT AREEQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED CONDUCTOR(S).TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES ADDRESS kW PHOTOVOLTAIC PLANSWHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED.USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. 4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X = AC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < #OFCOMBINEDPARALLELCIRCUITS QTY INPARALLEL &MATERIAL QTY INPARALLEL &MATERIAL DESTINATION MAX INV. OUTPUTCURRENT (AMPS)ORCOMPONENT(AMPS) lsc (AMPS)ORCOMPONENT(AMPS) PV MODULE INVERTER (1) CU 90 #12 AWG 30 10.62 1 1.25 1.25 16.6 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 16.6 28.8 INVERTER JUNCTION BOX (1) CU 75 #12 AWG 25 1.25 13.31 16.6 ROOFTOP 35 >7/8"0 35 0.94 2 N/A 25 0.94 1.0 23.5 16.6 23.5 AC COMBINER (1) CU 75 #10 AWG 35 1.25 13.31 16.6 ROOFTOP 35 0.5" – 3.5"0 35 4 0.80 350.94 0.94 0.80 26.32 16.6 26.32 AC DISCONNECT (1) CU 75 #8 AWG 50 1.25 26.62 33.3 EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 33.3 47.0 PRODUCTION METER (1) CU 75 #8 AWG 50 1.25 26.62 33.3 EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 33.3 47.0 EXISTING SERVICE PANEL (1) CU #8 AWG 50 1.25 26.62 33.3 EXT WALL 35 N/A 0 JUNCTION BOX AC COMBINER AC DISCONNECT PRODUCTION METER 75 35 0.94 3 1.0 50 0.94 1.0 47.0 33.3 47.0 E-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT LEGEND RELEASEREVDATE NAME ADDRESSDC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC#THREE LINE DIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 MICRO INVERTER 3 AC COMBINER BOX 4 JUNCTION BOX 5 NEW SOLAR LOAD CENTER 9 AC DISCONNECT (FUSIBLE) 7 PROD/GENERATION METER 8 SUB PANEL 10 11 12 EXISTING UTILITY METER GROUND CONDUCTOR TAGGND ELECTRICAL NOTES TAG APN ADDRESSBRANCH MODULE QTY OCPD BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 AC1 AC2 AC3 AC4 AC5 GROUND CONDUIT TABLE SIZE TYPE AC6 •INTEGRATED MICRO INVERTERS (AC MODULES) MUST BE CERTIFIEDUL1742 AND UL1703 COMPLIANT. AS EITHER INDIVIDUALCOMPONENTS OR AC MODULE ASSEMBLY. THEY MUST ALSO BELABELED "UTILITY INTERACTIVE" CONFORMING TO IEEE1547TESTING. •PV MODULES THAT HAVE INVERTERS ATTACHED WITHOUT AN ACMODULE EVALUATION BY A NRTL MAY VIOLATE THE ORIGINALLISTING OF THE PV MODULE AND VOID THE WARRANTY OFTHE MODULE. •VERIFY MODULE IS COMPATIBLE WITH MICRO INVERTERMANUFACTURER AND MODEL.•ARTICLE CEC/NEC 690 STILL APPLIES. THE INSTALLER WILL NEED TO CONSIDER REQUIREMENTS SUCH AS: DC GROUND FAULT DETECTION AND INTERRUPT, DC CABLE MANAGEMENT, DCDISCONNECTING MEANS AND DC GROUNDING AS WELL AS THE ACEQUIPMENT GROUNDING CONDUCTOR TO THE INVERTER. BACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS,UNLESS OTHERWISE MARKED, ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINE” AND “LOAD” SHALL NOTBE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITYINTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BE RATEDFOR 600 VOLTS ON THE DC / PV POWER SIDE OF THE INVERTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FORWET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FOR kW PHOTOVOLTAIC PLANSAC7 AC9 AC10 AC8 6 AC DISCONNECT AT GROUND LEVEL SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONSNOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS • INVERTER NAMEPLATE RATING 335W/240V MODULE NAMEPLATE RATING 335W L2 L1 G BUSRATING 3 AC3 125A L2L1 G N ENVOY-IQFOR MONITORING GEC N (-)(+) (-)(+) ACDC AC DC 2 2 11 MODULES 1 1 11 MODULES (+) (+) 2 2 ACDC(-) (-)DCAC 1 1 DC1 EGC AC1 20A G G L1 L1 L1 L1 L2 L2 L2 L2 L1 L1 L2 L2 AC2 20A 4 10A L2 L1 G N L2 L1 G N 9 N G L2 L1PV N G L2 L1 7 AC4 EGC AC5 G N BUSRATING 11 MAIN C/BRATING GEC 100 A 100 A M 12 LOCATED EXTERIORSOLAR GENERATION (LOAD) BOTTOM LUGS TO TOP LUGS TO UTILITY (LINE) NATIONAL GENERATION METERREADILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT(UTILITY ONLY) VISIBLE FROM APPROACH TO RESIDENCE 60A 240V LOCATED EXTERIOR ON WALL NEARMETER NEMA 3R FUSES 60A NOTE: CONDUCTORS AC3, AC4 & AC5 MAY BE THWN-2 OR SER CABLE(1) & (2) STRINGS (L1/L2 SHOWN) OF (11) MODULES 22 Hanwha Q-Cell Q.PEAK DUO-G6 335 Enphase IQ7PLUS-72-2-US (240V) Soladeck RSTC 0799-5B MA SMART GENERATION METER 1 11 20A 2 11 20A 120/240V - 1 #12 AWG PV Wire Open Air N/A NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER CEC/NEC 705.12(A) 22 1 2 0 0 1 0 1 0 Eaton DG222NRB 1 1 2 #6 AWG N/A 3 #12 AWG TRUNK CBL #6 AWG N/A Open Air 5 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT Enphase X-IQ-AM1-240-3 E-003NEW MAIN SERVICE PANEL EXISTING MAIN SERVICE PANEL 100A BUS/100A MB Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNELECTRICAL SYMBOL LEGEND SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP AC DISCONNECT PERFORMANCE METER UTILITY METER JUNCTION BOX AC P M ELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES NEED TO BE CONNECTED TO THE EGC(EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSOR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBSARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKINGSPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2.FOR "LAY-IN" LUG MODULE GROUNDING; CORRECTHARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED,TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BEATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TOBOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETAL PARTS THAT MIGHT COME INTO CONTACT WITHCURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THEMETAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS,DISCONNECTS, METERS, JUNCTION BOXES AND COMBINERBOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTSTO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THECONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THESYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT,OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECTCONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING,USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER.THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP ADDRESS kW PHOTOVOLTAIC PLANSAUTO TRANSFORMERATF SOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATT CLP CRITICAL LOADS PANEL JB XFMR TRANSFORMER SUB-PANELSUBACSPMACCP NORTH JB JB SCALE: 1/8” = 1’0” @ SHEET SIZE A3QTY 22 Hanwha Q-Cell Q.PEAK DUO-G6 335 MODULES QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER E-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSTANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSSHEET NOTES1SCALE:1/2" = 1'-0"CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 2 3 5 6 8 SCALE:1/4" = 1'-0"9 10 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12"FROM BENDS, 12" ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE: NEC 690.31(G)(3)3.MINIMUM OF 1 1/8" x 5 3/4" 4.FONT: 3/8" AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX, DC COMBINER, AND DC DISCONNECT WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SCALE:1/4" = 1'-0" 1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITSOR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSEDDURING SERVICE. 3.MINIMUM OF 3" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. NON-LOAD BREAK DC COMBINER / J-BOX WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SCALE:1/2" = 1'-0" 1.PLACED ON DC DISCONNECT(S) AND ON ANYEQUIPMENT THAT STAYS ENERGIZED IN THE OFFPOSITION FROM THE PV SUPPLY. 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 3 1/2" x 10" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. INVERTER(S)SCALE:1/2" = 1'-0" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 1.A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATEDON OR NO MORE THAN 1M (3 FT) FROM THE SWITCH THATINCLUDES THE FOLLOWING: 2. 3. MINIMUM OF 3 1/2" x 10 1/2" 4. FONT: 3/8" WHITE LETTERS ON A RED BACKGROUND. AC AND DC DISCONNECTS PV SYSTEM DISCONNECT 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 1" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/4" = 1'-0"SCALE:1/4" = 1'-0" DC COMBINER BOX 1. 2. USE PLACARD "COMBINER # 1" WHEN MORE THAN 1DC COMBINER IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1" x 4" 4. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR WHITE LETTERS ON A RED BACKGROUND. 1.CODE REFERENCE: NEC 690.13(C) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1" x 6" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1.USE PLACARD ON CUSTOMER GENERATION METER. 2.VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. SOLAR kWh METER SCALE:1/2" = 1'-0" INVERTER # 1 1.USE PLACARD "INVERTER # 1" WHEN MORE THAN 1INVERTER IS USED. NUMBER ACCORDING TO THREELINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1" x 4" 3.FONT: 3/8" 4.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/2" = 1'-0"INVERTER'S USE PLACARD "[AC][DC] DISCONNECT # 1" WHEN MORETHAN ONE DISCONNECT IS USED. NUMBER ACCORDING TOTHREE LINE DIAGRAM AND CALCULATIONS. 11 SCALE:1/4" = 1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.13 & 690.53) 4.THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLEASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALLTURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOWALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS ANDBARRIERS. (IFC 605.11.1.4, NEC 690.31[G][3] ) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATEOR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOTCOVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THELOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT, NON-BOLD. 7.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 7.4.CONTRASTING BACKGROUND AND LETTERING. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT CODE ABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE (IBC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY (UL) DO NOT DISCONNECT UNDER LOAD 7 RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZEDAND HAVING A MINIMUM HEIGHT OF 9.5 MM (3⁄8 IN.),IN WHITE ON RED BACKGROUND. 2. 1/4" = 1'-0"SCALE: 2CODEREFERENCE:NEC690.56(C)(1)(a) 3TITLE:MIN.3/8"BLACKCHARACTERSONYELLOWBACKGROUND,REMAININGCHARACTERSMIN.3/16"INBLACKONWHITEBACKGROUND. 1LOCATENOMORETHAN1mFROMTHESERVICEDISCONNTMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDSHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDSHUTDOWNSWITCHESIFNOTATTHESAMELOCATION. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS P-001QTY 22 Hanwha Q-Cell Q.PEAK DUO-G6 335 MODULES QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNDYNAMIC PLACARDS ADDRESS kW PHOTOVOLTAIC PLANS1.PRIME CONTRACTOR / PERMIT APPLICANT SIGNERIS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEMINSTALLATION. PRIME CONTRACTOR / PERMITAPPLICANT SIGNER WILL BE RESPONSIBLE FORCOLLECTION OF EXISTING ONSITE INFORMATIONREQUIREMENTS TO DESIGN, SPECIFY, AND INSTALLTHE EXTERIOR MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEM DETAILED IN THISDOCUMENT. 2.ADVANCED SOLAR SOLUTIONS, INC ISRESPONSIBLE FOR APPLYING SUPPLIEDINFORMATION INTO A SET OF PERMIT DRAWINGS.ANY CHANGES TO DRAWINGS ARE SUBJECT TOCONTRACT CONDITIONS BETWEEN THE CLIENTAND ADVANCED SOLAR SOLUTIONS, INC. INACCORDANCE WITH THE REQUIREMENTS OF THEAHJ. RESPONSIBILITY NOTES SHEET NOTES 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2. 4. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT, NON-BOLD. 5.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS.5.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS. 5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BEREDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT6.ANSI Z535.4-2014 PRODUCT SAFETY SIGNS AND LABELS: THISINFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDS MAY BE USED WITH PRIOR APPROVAL OF THE AHJ.MOST NOTABLE DIFFERENCES IS COLOR OF PLACARDS AND USEOF HAND WRITTEN VALUES WITH INDUSTRIAL MARKERS ONSTANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT AFUTURE DATE. I.E. ADDING MODULES AT A FUTURE DATE, ORSTANDARD PLACARD MANUFACTURER INSTALLED ONELECTRICAL COMPONENT. AHJ APPROVAL REQUIRED. (SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 2 3 4 SCALE:1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE:1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / AC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.54 4.MINIMUM OF 1 1/2" x 8 1/2" (TOP), 1 3/4" x 6 1/2" (BOT) 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1) PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEMSUPPLY BREAKER AT POINT OF INTERCONNECTION. (#2 & #3) PLACARD(S)REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT ARENOT LOCATED NEXT TO EACH OTHER. MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS. IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS; SEESHEET "E-001 / STRING INVERTER[#] SPECIFICATIONS". 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. 2.1.2."RATED AC OUTPUT CURRENT" WILL BE THE SUM OF THE INVERTERS2.1.3."AC NORMAL OPERATING VOLTAGE" WILL BE THE NAME PLATE RATING OF THEINVERTER 3.CODE REFERENCE: NEC 690.54, NEC 705.12(B)(3) 4.MINIMUM OF 2" x 6 1/2" (#1), VARIES (#2 & #3) 5.FONT: 3/8" HEADER, 3/16" DATA (#1), 1/4" (#2 & #3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PVINVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICEDISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEMDISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 7 3/4" x 5" 6.FONT: 3/4" "CAUTION", 1/4" "WARNING", 3/16" HEADER,1/8" DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEDISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERETHE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRCR331.2.3) MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE:1/2" = 1'-0" CAUTION 1.PLACARD PLACED AT ELECTRICAL SERVICE AND ATTHE PV INVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THESERVICE DISCONNECTING MEANS ANDPHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 6 1/2" x 6 1/2" 6.FONT: 3/4" "CAUTION", 1/4" HEADER, 1/8" DATAAND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAINSERVICE DISCONNECT IN A LOCATION CLEARLYVISIBLE FROM WHERE THE DISCONNECT ISOPERATED. (CFC 605.11.1.3 & CRC R331.2.3) AC COMBINER AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING SCALE:1/2" = 1'-0" 1. 2. USE PLACARD "COMBINER # 1" WHEN MORE THAN 1 AC COMBINER IS USED. NUMBERACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1" x 4" 4. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR MINIMUM. 5. WHITE LETTERS ON A RED BACKGROUND. PLACARDS MAY BE COMBINED TOGETHER. I.E. "AC COMBINER BOX #1". MINIMUM REQUIREMENTS LISTED ABOVE. AC COMBINER / DISCONNECT #1 AC SUB-PANEL #1 AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC COMBINER / DISCONNECT #2 AC SUB-PANEL #2 AC COMBINER / DISCONNECT #3 #1 #2 #3 CODE ABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE (IBC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY (UL) 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.53) N AC DISCO (E) UTILITY METER& SERVICE PANEL SOLAR ARRAYON ROOF TOP SOLAR ARRAYON ROOF TOP N AC COMBINER PRODUCTIONMETER AC DISCO (E) UTILITY METER& SERVICE PANEL AC COMBINER PRODUCTIONMETER 26.62 240 26.62 240 26.62 240 26.62 240 26.62240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT The new Q.PEAK DUO-G6 solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. Q.ANTUM’s world-record-holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding perfor- mance under real conditions — both with low-intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. THE IDEAL SOLUTION FOR: Rooftop arrays onresidential buildings 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information. ANTI PID TECHNOLOGY(APT) HOT-SPOT PROTECT(HSP) TRACEABLE QUALITY(TRA.Q™) YIELD SECURITY ANTI LID TECHNOLOGY(ALT) www.VDEinfo.comID. 40032587 Quality Tested high reliabilitylow degradationoptimized durabilitycontinous line monitoring üüüü 11/2016 Rooftop arrays on commercial / industrial buildings Q.PEAK DUO-G6 330-345 Q.ANTUM SOLAR MODULE MECHANICAL SPECIFICATION Format 1740 mm × 1030 mm × 32 mm (including frame) Weight 19.9 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction box 61-71 mm × 41-50 mm × 13-21 mm Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) 1150 mm, (−) 1150 mm Connector Multi-Contact MC4, IP68 QUALIFICATIONS AND CERTIFICATES PARTNER Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. 22%2%%%%/2%///%2 %2 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companieswith the highest production capacity in 2014 (as at: September 2014) ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP [W]330 335 340 345 Short Circuit Current1 ISC [A]10.57 10.62 10.68 10.73 Open Circuit Voltage1 VOC [V]39.74 39.99 40.24 40.49 Current at MPP IMPP [A]10.06 10.11 10.16 10.22 Voltage at MPP VMPP [V]32.81 33.13 33.45 33.76 Efficiency1 η [%]≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP [W]246.5 250.2 254.0 257.7 Short Circuit Current ISC [A]8.52 8.56 8.60 8.65 Open Circuit Voltage VOC [V]37.39 37.63 37.87 38.10 Current at MPP IMPP [A]7.92 7.96 8.00 8.04 Voltage at MPP VMPP [V]31.14 31.45 31.75 32.04 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 C, AM 1.5 G according to IEC 60904-3 ∙ 2800 W/m², NMOT, spectrum AM 1.5 G 2%%%%DETAIL A 16mm 8.5mm24.5mm 980mm1740mm 4 × Mounting slots (DETAIL A) Frame 1030mm 981mm 32mm 8 × Drainage holes 380mm 4 × Grounding points ø 4.5mm Label ≥1150mm ≥1150mm TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC α [% / K]+ 0.04 Temperature Coefficient of VOC β [% / K]− 0.28 Temperature Coefficient of PMPP γ [% / K]− 0.37 Normal Module Operating Temperature NMOT [°C]43 ± 3 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS [V]1000 Safety Class II Maximum Reverse Current IR [A]20 Fire Rating C Max. Design Load, Push / Pull [Pa]3600 / 2667 Permitted Module Temperature on Continuous Duty − 40 °C up to +85 °C Max. Test Load, Push / Pull [Pa]5400 / 4000 VDE Quality Tested, IEC 61215:2016; IEC 61730:2016, Application class AThis data sheet complies with DIN EN 50380.Specifications subject to technical changes © Hanwha Q CELLS Q.PEAK DUO-G6_330-345_2018-05_Rev01_ENHanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com At least 98 % of nominal power during first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement tolerances.Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions incomparison to STC conditions (25 °C, 1000 W/m2).RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSPV MODULE CUT SHEET R-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT 8IMTSIIQEMIE EIMEREIM EQEMEPPMQTPMIMREPPEMSRTSIMPI achievingthehighestsystemefciency. 4ESIRTEI-57IQI-5ER -51MSMRIIMRIEIMIRTEI -5RSRTEI-5EIERIRTEI Enlighten™monitoringandanalysissoftware. -57IMI1MSMRIIIIRIIPMEMPM EREISTIMSIRIEMSRER RISSIEQMPPMSRSSTSISRIMR IREPMRRTEISTSMIERMRPIEMR warrantyofupto25years. EI E MMII 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ EE7IIEIMMIIIMSR1-7 )EWXS-RWXEPP 0MLXIMLXERHWMQTPI *EWXIVMRWXEPPEXMSRMXLMQTVSIHPMLXIVXSMVIGEFPMR &YMPXMRVETMHWLYXHSRGSQTPMERX2) 4VSHYGXMIERH6IPMEFPI 3TXMQMIHSVLMLTSIVIHGIPPERHGIPPQSHYPIW 1SVIXLEREQMPPMSRLSYVWSXIWXMR PEWW--HSYFPIMRWYPEXIHIRGPSWYVI 90PMWXIH 7QEVX+VMH6IEH SQTPMIWMXLEHERGIHVMHWYTTSVXSPXEIERH VIUYIRGVMHIXLVSYLVIUYMVIQIRXW 6IQSXIPYTHEXIWXSVIWTSRHXSGLERMR VMHVIUYMVIQIRXW • Congurableforvaryinggridproles 1IIXW%6YPI907% 8LI-51MGVSMWVIUYMVIHXSWYTTSVXGIPPQSHYPIW2SIRSVGIH(%VEXMS7IIXLIGSQTEXMFMPMXGEPGYPEXSVEXLXXTWIRTLEWIGSQIRYWWYTTSVXQSHYPIGSQTEXMFMPMX2SQMREPSPXEIVERIGERFIIXIRHIHFISRHRSQMREPMVIUYMVIHFXLIYXMPMX0MQMXWQEEV6IIVXSPSGEPVIUYMVIQIRXWXSHIMRIXLIRYQFIVSQMGVSMRIVXIVWTIVFVERGLMRSYVEVIE 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ ©2018EnphaseEnergy.Allrightsreserved.AlltrademarksorbrandsusedarethepropertyofEnphaseEnergy,Inc. -2((-7-7 -77-77 SQQSRPYWIHQSHYPITEMVMRWz ;;;; 1SHYPIGSQTEXMFMPMXGIPP4:QSHYPIWSRPGIPPERHGIPP4:QSHYPIW 1EMQYQMRTYX(SPXEI :: 4IEOTSIVXVEGOMRSPXEI :::: 3TIVEXMRVERI :::: 1MR1EWXEVXSPXEI :::: 1E(WLSVXGMVGYMXGYVVIRXQSHYPI-WG%% 3IVSPXEIGPEWW(TSVX ---- (TSVXFEGOIIHGYVVIRX %% PVarrayconguration YRVSYRHIHEVVE2SEHHMXMSREP(WMHITVSXIGXMSRVIUYMVIH%WMHITVSXIGXMSRVIUYMVIWQE%TIVFVERGLGMVGYMX (-MVSMIVIV -MVSMIVIV 4IEOSYXTYXTSIV :%:% 1EMQYQGSRXMRYSYWSYXTYXTSIV :%:% 2SQMREP00SPXEIVERIs :::::::: 1EMQYQGSRXMRYSYWSYXTYXGYVVIRX %:%:%:%: 2SQMREPVIUYIRG,, )XIRHIHVIUYIRGVERI ,, %WLSVXGMVGYMXEYPXGYVVIRXSIVGGPIW %VQW %VQW 1EMQYQYRMXWTIV%00FVERGLGMVGYMXt :%:%:%:% 3IVSPXEIGPEWW%TSVX ------ %TSVXFEGOIIHGYVVIRX %% 4SIVEGXSVWIXXMR 4SIVEGXSVEHNYWXEFPIPIEHMRPEMRPIEHMRPEMR )--)2 PeakCECefciency CECweightedefciency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kW PHOTOVOLTAIC PLANSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-40RAIL 232-02449,232-02450,232-02451 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAILPROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 SECTION PROPERTIES A 0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³ DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 SPLICE 242-01213, 242-01214 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL N/A N/A 12 LB-FT UL 2703, FILE E359313 0.52 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, UR-40 SPLICE TAPPED PRC, CLEAR11 SNAPNRACK, UR-40 SPLICE THRU PRC, CLEAR12 SNAPNRACK, SNAPLINK BONDING CLIP, TYPE 2, STEEL23 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS14 1 2 4 3 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-60RAIL 232-02481,232-02482,232-02483 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 8.46 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 120 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-60 RAILPROPERTIES SKU FINISH 232-02481 MILL 232-02482 CLEAR232-02483 BLACK CENTROID .750 1.211 1.039 SECTION PROPERTIES A 0.515 in² Ixx 0.327 in⁴ Iyy 0.181 in⁴ Sx (TOP)0.270 in³ Sx (BOT)0.315 in³ Sy (LEFT)0.242 in³ Sy (RIGHT)0.242 in³ 2.250 1.500 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-60 SPLICE 242-01270, 242-01271 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL FULL UR-60 RAIL CAPACITY N/A 12 LB-FT UL 2703, FILE E359313 0.71 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS11 SNAPNRACK, UR-60 SPLICE, SLEEVE, CLEAR / BLACK12 SNAPNRACK, O-RING13 SNAPNRACK, UR-60 SPLICE, BONDING BRIDGE14 1 4 3 2 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT snapnrack.com 51 System Bonding Methods Grounding Specifications RAIL CHANNEL NUT MODULEFRAME MID CLAMP ASSEMBLY SS BONDING PIN NOTE: SnapNrack Mid Clamp SnapNrack Adjustable End Clamp SnapNrack UR-40 Rail Splice SnapNrack UR-60 Rail Splice q   SnapNrack module clamps contain a SnapNrack Channel Nut with integral bonding clips or pins in assembly to properly bond the system (except Universal End Clamps). Note: SnapNrack Ground Lug Assembly SNAPNRACKULTRA SERIES RAIL 5/16"-18 X 1" BOLT S.S.WITH SPLIT LOCK WASHER S.S. SNAPNRACK GROUNDLUG, 6-12 AWG SNAPNRACK BONDINGCHANNEL NUT COPPER WIRE, TYP. SS BONDING CLIP(2 TOTAL)RAIL SPLICEASSEMBLY SnapNrack Ultra Rail Splices contain integral bonding clips in assembly to properly bond the system. Note:  RAIL SPLICEASSEMBLY SS BONDING PIN(2 TOTAL) snapnrack.com 52 Grounding Specifications Ground Path Details Ilsco Lay-in Lug Assembly SNAPNRACKULTRA SERIES RAIL #10 BOLT SS ILSCO GBL-4DBT GROUND LUG #10 NUT SSWITH STAR WASHER COPPER WIRE, TYP. GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP TO EGC RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT snapnrack.com 53 Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP ENPHASEMICRO-INVERTER GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP SOLAREDGEOPTIMIZER TO EGC TO EGC Ground Path Details - Enphase Ground Path Details - SolarEdge snapnrack.com 54 INSTALLATION INSTRUCTIONS - SNAPNRACK GROUND LUG 1) Snap the SnapNrack Ground Lug into the rail channel on one rail per module row. 2) Place grounding conductor into slot underneath split ring washer. SnapNrack Ground Lug may be used in side or top channel, and may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. Install Note: SnapNrack Ground Lug only Listed for use with 6-12 AWG solid copper conductor. Install Note: 3) Tighten hardware to 16 ft-lbs. Grounding Specifications INSTALLATION INSTRUCTIONS - ILSCO LAY-IN LUG 1) Drill and deburr a 1/4” hole in the back side of the rail for the Ilsco lug to attach to, place the bolt through the hole, and attach the lug assembly on one rail per module row. 2) Place grounding conductor into slot. Torque rail connection to 35 in-lbs. Install Note: Torque set screw to 20 in-lbs for #10- #14 solid and stranded copper, 25 in-lbs for #8 stranded copper, and 35 in-lbs for #4-#6 stranded copper. Install Note: 3) Tighten set screw per Ilsco’s recommendation (see below). • System has been evaluated to a maximum overcurrent device (OCD) protection level of 20 Amps. • Universal End Clamp (UEC) does not bond module to rail. Be sure to separately ground any modules that are only secured by UECs, especially during servicing.• SnapNrack recommends that bare copper never come into contact with aluminum. • SnapNrack Ground Lug: torque bolt to 16 ft-lbs. The Ground Lug may be used in side or top channel. It may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. • Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling of a hole in the rail. • Ilsco hardware connection to rail: 5 ft-lbs. Torque for lug set screw: #10-#14 solid and stranded copper- 20 in-lbs, #8 stranded copper- 25 in-lbs, #4-#6 stranded copper- 35 in-lbs. Note:RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT snapnrack.com 55 Ground Path Details - DynoBond Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)M M M M M M M M E E TO EGC MOUNT M MODULE CLAMP M = MIDCLAMPE = END CLAMP(+)(-)E E M M M M E E E E DYNORAXX DYNOBOND R/C (QIMS2), DynoRaxx (E357716) photovoltaic bonding jumper cat. no. DynoBond is an optional component that may be used with this system. The DynoBond jumper has been evaluated to provide module to module bonding. The DynoBond device attaches to the frame flange of adjacent modules. 1/953 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Subject: Engineering Certification for the State of Massachusetts Building Codes:1.ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2.2015 International Building Code, by International Code Council, Inc. 3.2015 International Residential Code, by International Code Council, Inc. 4.AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5.Aluminum Design Manual 2015, by The Aluminum Association, Inc. 6.ANSI/AWC NDS-2015, National Design Specification for Wood Construction, by the American Wood Council Design Criteria:Risk Category II Seismic Design Category = A - E Basic Wind Speed (ultimate) per ASCE 7-10: up to 190 mph Ground Snow Load = 0 to 120 (psf) This letter certifies that the loading criteria and design basis for the SnapNrack Ultra Rail Racking System with UR-40 Rail Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA August 6, 2019 PZSE, Inc. – Structural Engineers has provided engineering and span tables for the SnapNrack Ultra Rail Racking System with UR- 40 Rail, as presented in PZSE Report # 2017-03227.11, "Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Re: Report # 2017-03227.11 – SnapNrack Ultra Rail Solar Photovoltaic Racking System with UR-40 Rail RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 n1.00 4.20 .30 3.25 n1.00 1.00 SLOT 1.50 2.78 1.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM n.35 1.80 105°RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-109Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT 8I)EI-QMIRTEI -RSSRSPEIRIVSRRISR ITQIRRSERPIIRPSVIER VIEQPRIERSVEIREPPESR TVSRESRIRTVIVISPSRSV VIIREPETTPESR-SIVTSSV TSPIRTVERESRIVI EVEIQP )EI -QMI -1 8SPIEVRQSVIEFSX)RTLEWISIVRKWWX EEII )EI2IXM QEVX -RPIW-)RSSVSQQREXSR ERSRXVSP PIFPIRIXSVORKWTTSVXW )XLIVRIXSVIPPPEV 3TXSREPVIITXEPIEEPEFPISV40 FVKI 4VSIWTVSXSRQIXIVRKERSTXSREP SRWQTXSRQSRXSVRK QTPI 6IIWIVSQTVISWSQFRIV IRXIVIQSRXRKFVEOIXWWTTSVXWRKPI WXQSRXRK TTSVXWFEOERWISRXIRXV 9TXSSVTSPIFVERLVXWSV TPKRFVIEOIVWRSXRPI XSXEP4SVWXSVEKIFVERLVXW 6IPEFPI • DurableNRTL-certiedNEMAtype 6IRPSWVI IIEVEVVERX 90PWXI 8SPIEVRQSVIEFSX)RTLEWISIVRKWWX kRTEIRIVPPVVIIVIPPVEIQEVSVVERRSQIREVIVIIVIIVVITIISRIV IQCombiner3X-IQ-AM1-240-3 -SQFRIVXL)RTLEWI-)RSTVRXIVXFSEVSVRXIKVEXIVIIRIKVEI4productionmetering(ANSIC12.20+/-0.5%)andoptional*consumptionmonitoring(+/-2.5%). ERRSXRPISVIVWITEVEXIP EnphaseMobileConnect™CELLMODEM-03(4G/12-yeardataplan)CELLMODEM-01(3G/5-yeardataplan)CELLMODEM-M1(4GbasedLTE-M/5-yeardataplan) 4PKERTPERWXVEPKVEIIPPPEVQSIQXLEXETPERSVWWXIQWTXSmicroinverters.(AvailableintheUS,Canada,Mexico,PuertoRico,andtheUSVirginIslands,wherethereisadequatecellularserviceintheinstallationarea.) ConsumptionMonitoring*CT840-8 Splitcorecurrenttransformersenablewholehomeconsumptionmetering(+/-2.5%). VXVIEOIVWBRK-10A-2-240BRK-15A-2-24064 SupportsEatonBR210,BR215,BR220,BR230,BR240,BR250,andBR260circuitbreakers.Circuitbreaker,2pole,10A,EatonBR210Circuitbreaker,2pole,15A,EatonBR215VXFVIEOIVTSPI)EXSR6 EPLC-01 4SIVPRIEVVIVSQQREXSRFVKITEVUERXX XA-PLUG-120-3 AccessoryreceptacleforPowerLineCarrierinIQCombiner3(requiredforEPLC-01) )246ITPEIQIRX-)RSTVRXIVXFSEV4SVSQFRIV 6EXRK SRXRSWX WXIQSPXEKI 120/240VAC,60Hz )EXSR6WIVIWFWFEVVEXRK 125A Max.continuouscurrentrating(outputtogrid)65A Max.fuse/circuitrating(output) Branchcircuits(solarand/orstorage)Uptofour2-poleEatonBRseriesDistributedGeneration(DG)breakersonly(notincluded) Max.continuouscurrentrating(inputfromPV) Max.totalbranchcircuitbreakerrating(input)80Aofdistributedgeneration/90AwithIQEnvoybreakerincluded ProductionMeteringCT WSPSVITVIRWXEPPIERVIXS-)RS Dimensions(WxHxD)49.5x37.5x16.8cm(19.5”x14.75”x6.63”).Heightis21.06"(53.5cmwithmountingbrackets). IKLX 7.5kg(16.5lbs) QFIRXXIQTIVEXVIVERKI -40ºCto+46ºC(-40ºto115ºF) SSPRK 2EXVEPSRIXSRTPWLIEXWLIP )RPSWVIIRVSRQIRXEPVEXRK Outdoor,NRTL-certied,NEMAtype3R,polycarbonateconstruction VIWIW 20Ato50Abreakerinputs:14to4AWGcopperconductors60Abreakerbranchinput:4to1/0AWGcopperconductorsMainlugcombinedoutput:10to2/0AWGcopperconductorsNeutralandground:14to1/0copperconductorsAlwaysfollowlocalcoderequirementsforconductorsizing. PXXI To2000meters(6,560feet) -RXIKVEXI802.11b/g/n )XLIVRIX Optional,802.3,Cat5E(orCat6)UTPEthernetcable(notincluded) IPPPEV Optional,CELLMODEM-01(3G)orCELLMODEM-03(4G)orCELLMODEM-M1(4GbasedLTE-M)RSXRPI SQTPERISQFRIV UL1741CAN/CSAC22.2No.107.147CFR,Part15,ClassB,ICES003Productionmetering:ANSIC12.20accuracyclass0.5(PVproduction) SQTPERI-)RSUL60601-1/CANCSA22.2No.61010-1 *ConsumptionmonitoringisrequiredforEnphaseStorageSystems. )EI-QMIRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC COMBINER CUT SHEET R-110Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT pe.eaton.com General Duty Cartridge Fuse Safety Switch DG222NRB UPC:782113144221 Dimensions: Height: 7 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Cartridge Fuse Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Class Provision: Class H fuses Fuse Configuration: Fusible with neutral Number Of Poles: Two-pole Number Of Wires: Three-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222NRB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy-duty switches incorporate these K-Series switch design features. ●Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism ●Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-111Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.370Obrien, John14 Reservoir RdLeeds, MA 0105308/10/2020SUBMIT FOR PERMIT