Loading...
31C-081 117 OLANDER DR-UNIT 4A&4B BP-2019-0943 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 3 1 C-081 CITY OF NORTHAMPTON ot: - PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:NEW DUPLEX BUILDING PERMIT Permit# BP-2019-0943 Project# JS-2019-001579 Est. Cost: $233000.00 Fee: $1715.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: SHAUL PERRY 065400 Lot Size(ss .ft.): Owner: SUNWOOD DEVELOPMENT CORP Zoning: Applicant: SHAUL PERRY AT: 117 OLANDER DR - UNIT 4A & 413 Applicant Address: Phone: Insurance: 84 POTWINE LN (413) 259-1000 WC AMHERSTMA01002 ISSUED ON:3/6/2019 0:00:00 TO PERFORM THE FOLLOWING WORK.-NEW CONSTRUCTION OF 2,000 SQ FT DUPLEX POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of lumbing Inspector of Wiring D.P.W. Building Inspector �,12 � I Tnder r u Service: Meter: Footings: Rough: Rough- House# Foundation: ,5 v/'Q —,ePm Driveway Final: Final: 7`2 7- Za Final:l,� -)3 ��'✓ e%� �-o� �. 1A Rough Frame: �l� ✓r/8�`� C,l� C Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: d K Final: Smoke: v 749o?, Final: gA. 0.1/ 7-28-ZOZO11-12 ge a v. 8-"-zoZo kR THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLLATION OF ANY OF ITS RULES AND R IONS. Certificate of Occupancy / Si nature: FeeTvpe: Date Paid: Amount: Ruilding 3/6/2019 0:00:00 $1715.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner OLANDER DR- UNIT 4A&4B BP-2019-0943 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 3 1 C-081 CITY OF NORTHAMPTON Lot: - PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL e.142A) Category:NEW DUPLEX DING PERMIT Permit# BP-2019-0943 Project# JS-2.019-001579 Est. Cost: $233000.00 Fee: $225.00 PERMISSION IS IIEREBY GRANTED TO: Const. Class: Contractor: License: Use Group SHAUL PIERRY 005400 Lot Sizes . fa t.): Owner: SUN WOOD DFVELOPMENT CORP 7Vning.:_ AEplicant: SHAUL PERKY AT. OLANDER DR - UNIT 4A & 413 A elicantAddress: Phone: Insurance, 8-f POTWINF LN � (413 259-1000 we AMHERSTMA01002 ISSUED ON.316120190:00:00 TO PERFORM THE FOLLOWING WORK:NEW CONSTRUCTION OF 2,000 SQ FT DUPLEX - FOUNDATION ONLY POST THIS CARD SO IT IS VISIBLE FROM THE STR ET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Juderground: Service: Meter: Footings: Rough: Rough: IioUtiv 1 Foundation; Vrivcway Final: Final; Final; Rough Frame: Gas: Fire Denartment Fireplace/Chimney: Rough` i Insulation; Final: S ce: at 7�?�d Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy FeeTvl)e: Date Paid: Atrlount: wilding 3/6%2014 0.00;04 $225.00 212 Main Strut, Ittltlne(413)5$a-1240, Fiw (413)387-1272 Louis Flasbruuck--Building Commissioner y�Fri tsr The Commonwealth of Massachusetts City of Northampton YYY � Certificate of Occupancy In accordance with 780 CMR, (The Ninth Edition of the Massacliusetts Residential Building Code) this Certificate of Occupancy is issued to the premise or structure or part thereof as herein identified. Identify Name of Building of Space Within, Building Owner, or Permit Holder Certificate No. Issued to Sunwood Development Corporation BP-2019-0943 Identify property address including street number, name, city or town and county Located at 117 Olander Drive Unit 4A & 4B Northampton, Hampshire, Massachusetts Use Group Two Family Dwelling Hers Rating Unit 4a Classification(s) Hers Rating Unit 4b 36 This Certificate of Occupancy is hereby issued by the undersigned to certify that the premise,structure or portion thereof as herein specified has been inspected for general fire and life safety features. This certificate shall allow for the use as herein described and in conformance with any and all conditions as identified below. It shall be posted in a conspicuous place within the space as directed by the undersigned. Failure to post the certificate,failure to comply with conditions or, tampering with the contents of the certificate is strictly prohibited. Conditions of Use Two Family Dwelling All fire protection and life safety systems must be maintained, and all means of egress must be kept clear Name of Municipal Date of Final Map/Plot: Buildin Official Kevin Ross Inspection 08/04/2020 Signature of Municipal Date of 31 C-U81 Building Official Issuance 08/07/2020 Home Energy Rating Certificate Rating Date: 2020-08-01 HIS � Registry I0: 530080817 HERS Final Repan Ekotrope ID: 7dBanooL Index Your Olander Drive #4a performance score.The lower the number, $ 2,811 • t i !•1 the • ihome, i . • 30learn more,visit www.hersindex.com "Relative to an average U.S.home Sunwood Builders Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtul Annual Cost criteria of the following: Heating 4.4 $217 2015 International Energy Conservation Code Cooling 0.4 $16 Hot Water 2.2 $101 Lights/Appliances 13.5 $621 Service Charges $72 Generation (e.g.Solar) 0.0 $0 Total: 20.4 $1,027 HERSIndex Home Feature Summary: Rating Completed by: M.Ftwa Home Type: Duplex,single unit Model: N/A Energy Rater: Adin Maynard Community: VHCoHousing RE5NET Ib:9463452 Conditioned Floor Area: 1,325 ft' Rating Company: HIS&HERS Energy Efficiency Number of Bedrooms: 3 Mailing:12 Perkins Ave.Northampton MA 01(X30 ger"H0M0 s100 Primary Heating System: Air Source Heat Pump"Electric-3.56 COP 4136588784 Primary Cooling System: Air Source Heat Pump-Electric•21.7 SEER Rating Provider: Enerqy Raters of Massachusetts Primary Water Heating: Water Heater•Electric-3.55 Energy Factor 2 Woodlawn Street Amesbury,MA 01913 978`270-3911 House Tightness: 270 CFM50(0.92 ACH50) _ Ventilation: 53 CFM•24 Watts j° �° ;s 'r' Duct Leakage to Outside: Untested ' t Above Grade Walls: R-28 f. Ceiling: Attic,R.60 Zero Energy Ma,r,e o WindowType: U-Value:0.23,SHGC:0.21 Adin Maynard,Certified Energy Rater u••e,wM I Foundation Walls: R-15 Digitally signed:8/5/20 at 9:03 AM Ekotrope. ekotropw The Energy Rating Disclosure for this home is available from the Approved Rating Provider, This re.port does not constitute any warranty of 2015 IECC R-406 RESNET Registered Energy Rating Index Report Property ion Energy Rating Index Information Builder:Sunwood Builders Company:HIS & HERS Energy Efficiency RESNET Registered Rating Address: Phone:4136588784 Rating No:530080817 117{dander Drive#4a, Northampton, MA Rater:Adin Maynard Rater ID (RTIN):9463452 01060 Date Rated:2020-08-01 HERS' Index Estimated Annual Energy Consumption* Mw*EneW Rated Home Calculated Rated Home Cost ($/yr) Energy Use (MBtu) ghomes 150 1 E 140 Heating 4.4 $217 Cooling 0.4 $16 120 Water Heating 2.2 $101 Reference goo 3.10 Lights&Appliances 13.5 $621 Home 90 1 Photovoltaics 0.0 $0 $1,027 'Based on Manoard coerating conditions 60 so ERI with PV:30 ERI without PV.30 so nft Annual Estimates Zero energy Electric(kWh):5,988.9 CO2 Emissions(Tons):3.8 Home .0 LeSYJ EnergV Natural Gas(Therms):O.O Energy Savings ($)**.N/A —Based on the K15 IECC R4%Reference design home Maximum Energy Rating Index:55 This Home's Energy Rating Index:30PASS This home MEETS the Energy Rating Index Score requirement of 2015 IECC 8-406 for Climate Zone 5. It MEETS all of the requirements verified by Ekotrope. Mandatory requirements are summarized on the 2nd page of this report, some of which are not verified by Ekotrope. Name: Adin Maynard Signature: Organization: HIS &HERS Energy Efficiency Digitally signed: 8/5120 at 9:03 AM Rating Provider Data and Seal Company:Energy Raters of Massachusetts V Address:2 Woodlawn Street Amesbury, MA 01913 r Phone#:978-270-3911 in Fax#: To determine if a provider is properly accredited go to:www.resnet.us/professionaUprograms/Search—dhvctory (Confirmed and tested) Climate Zone 5 MandatoryRequirements Provision Number Topic Compliance Decision 2009 IECC Table Building thermal envelope minimum insulation levels and PASS 402.1.1 or 402.1.3 maximum fenestration U-factor and SHGC R401.3 Post a permanent certificate listing the level of efficiencies Certificate required for CO installed in the house 8402.4.1.2 t Envelope air leakage maximum leakage rate PASS R402A.1 l Table ' Comply with air sealing and insulation requirements in Table Checklist required for CO 8402.4.1.1 8402.4.1.1 R402.4A Rooms containing fuel-burning appliances PASS* R402.5 Maximum fenestration U-factor and SHGC (U-Factor) PASS {SHGC} PASS R403.1.2 ? Heat pump controls PASS* I R406.2 Ducts outside of conditioned space to be insulated to a PASS* 3 minimum of R-6. I R403.3.2 Duct sealing on all ducts PASS` i R403.3.3 Duct testing for ducts in unconditioned space PASS* R403.3.5 Building cavities not used as ducts. PASS' i R403.5.1 Heated water circulation and temperature maintenance PASS` j systems comply R403.5.3 Hot water pipe insulated to R-3 PASS R403.6 Mechanical ventilation meeting the requirements of the IRC PASS` or IMC. Outdoor air and exhaust dampers installed R403.7 RCCA Manual J and S conducted for all heating and cooling ACCA forms required for systems. permit R403.8 Systems serving multiple dwe"!:ng units to meet the PASS* mechanical requirements of IECC commercial code R403.9 Snow melt and ice system controls installed where applicable PASS* R403.10 F Pools and permanent spa energy consumption meet PASS* requirements for heaters, time clocks and covers E R403.11 Portable spas meet the requirements of APSP-14. PASS* R404.1 High efficacy lights installed in 75%of permanently installed PASS fixtures. 'These items have been field-verified by the Rater,Field Inspector, Code Inspector,or Builder_ it 117 01ander Drive a Northampton, MA 01060 Builder: Sunwood Builders Community: VHCoHousin THIS HOME IS CERTIFIED TO MEET THE 2015 INTERNATIONAL ENERGY CONSERVATION Building Features Ceiling Attic, R-60 Duct Supply R-6.0, Return R-6.0 Above Grade Walls R-28 Duct Leakage to Outside Untested Foundation Walls R-15 Total Duct Leakage Untested Framed Floor N/A Heating Air Source Heat Pump- Electric• 3.56 COP Slab R-0.0 Perimeter, R-10.0 Cooling Air Source Heat Pump• Electric• 21.7 SEER Under Infiltration 270 CFM50(0.92 ACH50) Water Heating Water Heater• Electric• 3.55 Energy Factor Window U-Value: 0.23, SHGC: 0.21 As a 3rd party extension of the crate Jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter A of the adopted international Energy Conservation Code based on Climate Zone 5,if rating is Projected,I certify that the building design described herein is consistent with the building plans,specifications,and other calculations submitted with the permit application.if rating is Confirmed.t certify that the address referenced above has been inspecteditested and that the mandatory provisions of the IECC have been installed to meet or exceed the Intent of the IECC or will be verified as such by another party. Name: Adin Maynard Signature: Organization: HIS & HERS Energy Efficiency Digitally signed: 8/5/20 at 9:03 AM Ekotrope RATER-Version 3.2.3.2497 2015 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETAocredited HERS Rating Tod.Al results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on dais report- IECC 2015 Label 997 01ander Drive #4a Ekotrope RATER-Version: 3.2.3.2497 HERS) Index Scare: 30 ilding Envelope Specs _. Ceiling: R-60 Above Grade Wails: R-28 Foundation Walls: R-15 Exposed Floor: NIA Slab: R-10 Infiltration: 270 CFM50 (0.92 ACH50) Duct Insulation: NIA Duct Lkg to Outdoors: Untested Window & Door Specs �: w U-Value 0.2:3, SHGC 1' 21 Door: R-5 Mechanical Equipment Specs Heating:Air Source Heat Pump - Electric - 3.56 COP Cooling:Air Source Heat Pump• Electric-25.7 SEER Hot Water: Water Heater- Electric- 3.55 Energy Factor Builder or Design Professional ___._ Air Leakage Report Property Organization Inspection Status NIS 117Olander Drive#4a HIS& HERS Energy Effici, 2020-08-01 HERS Northampton, MA 01060 Adin Maynard Rater ID(RTIN): 9463452 Community: VHCoHousing 4136588784 RESNET Registered (Confirmed) Coho—Unit4a—38R BIdng2_FnI Builder VHCoho—Unit 4a—FnI Sunwood Builders General Information Conditioned Floor Area Ift2l 1,325 Infiltration Volume [ft"] 17,660 Number of Bedrooms 3 Air Leakage Measured Infiltration 270 CFM50(0.92 ACH50) ACH50(Calculated) 0.92 ELA[sq. in.] (Calculated) 14.85 ELA per 100 s.f. Shell Area (Calculated) 0.358 CFM50(Calculated) 270 CFM50/s.f. Shell Area (Calculated) 0.065 Duct Leakage Leakage to Outdoors Total Leakage Test Type Total Leakage[CFM @ 25 Pa] Total Leakage[CFM25/ 100 s.f.] Total Leakage[CFM25/CFA] Mechanical Ventilation Rate [CFM] 53 CFM Hours per day 24.0 Fan Power 24 Wafts Recovery Efficiency% 80.0 Runs at least once every 3 hrs? true Average Rate[CFM] 53.0 CFM 2010 ASHRAE 62.2 Req. Cont. Ventilation 43.3 2013 ASHRAE 62.2 Req. Cont.Ventilation 69.8 Ekotrope RATER-Version 3.2.3.2497 All results are based on data entered by Ekotrope users.Ekotrope disclaims all liability for the information shown an this report. RESNET HOME ENERGY HIS RATING Standard Disclosure HERS For home(s) located at: 117 Olander Drive #4a, Northampton, MA Check the applicable disclosure(s): 1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: L]A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel L-. E. Other(specify) [13.The Rater or the Rater's employer is: A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C.An employee, contractor, or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products Installed in this home by OR is in the business of HVAC systems Rater Employer Rater Employer Thermal insulation systems "'IRater Employer Rater Employer Air sealing of envelope or duct systems Rater MIlEmployerRaterEmployer Energy efficient appliances '----IRater ElEmployer `Rater Employer Construction (builder, developer, construction contractor, etc) Rater EmployerRater Employer Other(specify): Rater Employer €Rater ' Employer E15. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling"of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 9463452 Name: Adin Maynard Signature: Organization: HIS & HERS Energy Efficiency Digitally signed: 8/5120 at 9:03 AM I attest that the above information is true and correct to the best of my knowledge.As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 102.1.4.6 of the standard and are posted at https://standards.resnet.us The Home Energy Rating Standard Disclosure for this home its available from the rating provider. HERS'* Index Score: Annual Savings Home: Your Dome's HERS score is a relative 117 Ola nder Drive #4b performance sure.The lower the number, Northampton, MA 01060 the more energy efficient the homes To $2,032 Bl,1$Ider. 3 learn more,visit www.hersindex.com *Relative to an average U.S.home Sunulood Builders MFRS"Index # ! ! p Wg 41 i i ! s 1 F s r s ! e i a i ' + " • t IF f ♦ I t A � • i 't Ekotrope RATER-Version.3.23.2497 ekotrope The Energy Rating Disriosure for this home is available from the Approved Mating Provider. This report does not COnStitUte any warrant or guarantee. 2015 IECC R-406 RESNET ERIE Reg*stered Energy Rating Index Reoft Property Organi pation Energy Rating Index Information Builder:Sunwood Builders Company:HIS&HERS Energy Efficiency RESNET Registered Rating Address: Phone:4136588784 Rating No:889968038 117 Oiander Drive#4b, Northampton, MA Rater:Adin Maynard Rater ID (RTIN):9463452 01060 Date Rated:2020-08-01 ——— -------------------- HERS' Index 46- AmEr&W Rated Home Calculated Rated Home Cost($/yr) M Energy Use (MBtu) Existing Heating 3.8 $185 Homes Cooling 0.3 $14 Water Heating 1.9 $88 Reference Lights &Appliances 13.4 $617 Home 100 Photovoltaics 0.0 $0 r,.-d ern.1-d.,d ERI with PV,.36 ERI without PV-36 20 This Homt jjrgr -5 Zero EH,gy Electric (kWh):5,677.7 CO2 Emissions (Tons):3.6 me Natural I (Therms) T er �O Energy i gs($r_ N ra Gas h S En Savings N/A Less Energy Natural Gas (Therms):O,O Energy Savings "Dased or,tt*2015 1EC-1 8-406 Peteremc-de"n hww SS This home MEETS the Energy Rating Index Score requirement of 2015 IECC R-406 for Climate Zone 5. It MEETS all of the requirements verified by Ekotrope. Mandatory requirements are summarized on the 2nd page of this report, some of which are not verified by Ekotrope. Name: Adin Maynard Signature: Organization: HIS &HERS Energy Efficiency Digitally signed: 8/5/20 at 9:00 AM Company:Energy Raters of Massachusetts Address:2 Woodlawn Street AmesbuMA 01913 Phone#:978-270-3911 Fax#: To determine if a provider is properly accredited go to:www.resnet.usiprofessional/programslsearch—directory --.....................-... ..................—............ (Confirmed and tested) -NE' Milinate Zitihii 5 MIEN Provision Number Topic Compliance Decision 2009 iECC Table wilding thermal envelope minimum insulation levels and PASS 4012.1.1 or 402.1.3 maximum fenestration U-factor and SHGC 8401.3 Dost a permanent certificate listing the level of efficiencies 1 Certificate required for CO installed in the house 84{}2.4.1.2 Envelope air leakage maximum leafage rate PASS R402,4.1 J Table Comply with air sealing and insulation requirements in Table Checklist required for CO 8402.4,1,1 8402.4.1.1 8402.4.4 Rooms containing fuel-burning appliances PASS* 8402.5 Maximum fenestration U-factor and SHGC (U-Factor) PASS i 1 (SHGC) PASS R4031.2 Heat pump controls PASS* 8406.2 £ Ducts outside of conditioned space to be insulatedto a PASS'S minimum of R- . 8403.3.2 Duct sealing on all ducts PASS` R4033.3 Duct testing for ducts in unconditioned space PASS" i 8403.3.5 Building cavities not used as ducts. PASS" 84015.1 Heated water circulation and temperature maintenance PASS" systems comply 84173.5.3 Hot water pipe insulated to R-3 PASS R403.6 Mechanical ventilation meeting the requirements of the IRC I PASS" or IMC. Outdoor air and exhaust dampers installed R403.7 RCCAManul J and S conducted for all heating and ding ACGA forms required for systems. permit 8403.5 Systems serving multiple dwc!'ing units to meet the PASS` 1 mechanical requirements of IECC commercial code 84019 Snow melt and ice system controls installed where applicable PASS- R40310 Fools and permanent spa energy consumption meet PASS" requirements for heaters, time clacks and covers { R403.11 Portable spas meet the requirements of Al'SP-14. ;, PASS* l R404.1 High efficacy lights installed in 75%of permanently installed PASS fixtures. These Items have been field-verified by the Rater. Field inspector, Code Inspector, or Builder. 117 01aDrive #4b Northampton, MA 01060 Builder: Sunwood Builders Community: VHCol-lousing THIS HOME IS CERTIFIED TO MEET THE 2015 INTERNATIONAL ! ' • CODE Building Features Ceiling Attic, R-60 Duct Supply R-6.0, Return R-6.0 Above Grade Walls R-28 Duct Leakage to Outside Untested Foundation Walls R-15 Total Duct Leakage Untested Framed Floor N/A Heating Air Source Heat Pump• Electric- 3.66 COP Slab R-0.0 Perimeter, R-10.0 Cooling Air Source Heat Pump• Electric• 18 SEER Under Infiltration 270 CFM50(1.33 ACH50) Water Heating Water Neater• Electric*3.55 Energy Factor Window U-Value: 0.23, SHGC: 0.21 Asa 3rd party extension of the rade Jurisdiction utilizing these reports. t rrtify that this energy code compliance document has been created In accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5,if rating Is Projected,I certify that She building design described herein is consistent with the building plans.specifications,and other calculations submitted with the permit application.l(rating Is Confirmed,I certify that the address referenced above has been Inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Adin Maynard Signature: Organization: HIS tar HERS Energy Efficiency Digitally signed: 13!5!20 at 9:00 AM Ekotrope RATER-Version 3.2.3.2497 20155 IECC compliance results calculated using Ekotrope RATER's energy and Gude compliance algorithm, Eketrope RATER is a RESNET Accredited HERS Rating Taal.Al results are based an data entered by Ekulrope users. Ekotrope disclaims all liability for the information shown on this report. IECC 2015 Label 117 01ander Drive #4b Ekotrope RATER- Version: 3.2.3.2497 HERS® Index Score: 36 Building Envelope Specs ; ;.`I Ceiling: R-60 Above Grade Walls: R-28 Foundation Walls: R-15 Exposed Floor: N/A Slab: R-1Q Infiltration: 274 CFM50 (1.33 ACH50) Duct Insulation: N/A Duct Lkg to Outdoors: Untested Window & Door Specs U-` alue 3.23. SHGC 0.21 Door: R-5 Mechanical Equipment Specs 'Heating:Air Source Heat Pump • Electric- 3.66 COP Cooling:Air Source Heat Pump • Electric- 18 SEER Hot Water: Water Heater - Electric•3.55 Energy Factor Builder or Design Professional;; Air Leakage Report Organization Inspection Status Property HIS ,- 117 Olander Drive#4b HIS& HERS Energy Effici, 2020.08-01 HERS Northampton, MA 01060 Adin Maynard Rater ID (RTIN): 9463452 Community: VHCoHousing 4136588784 RESNET Registered (Confirmed) Coho,—Unit4b—2BR—BIdng2_FnI Builder VHCoho—Unit 4b—FnI Sunwood Builders General Information Conditioned Floor Area[ft2] 909 Infiltration Volume [ft'] 12,156 Number of Bedrooms 2 Air Leakage Measured Infiltration 270 CFM50(1.33 ACH50) ACH50(Calculated) 1.33 ELA[sq. in.] (Calculated) 14.85 ELA per 100 s.f. Shell Area (Calculated) 0.450 CFM50(Calculated) 270 CFM50/s.f. Shell Area (Calculated) 0.082 Duct Leakage Leakage to Outdoors Total Leakage Test Type Total Leakage[CFM @ 25 Pa] Total Leakage[CFM25/ 100 s.f.] Total Leakage[CFM25/CFA] Mechanical Ventilation Rate [CFM] 53 CFM Hours per day 24.0 Fan Power 24 Watts Recovery Efficiency% 80.0 Runs at least once every 3 hrs? true Average Rate[CFM] 53.0 CFM 2010 ASHRAE 62.2 Req. Cont. Ventilation 31.6 2013 ASHRAE 62.2 Req. Cont.Ventilation 49.8 Ekotrope RATER-Version 3.2.3.2497 A results are based on data entered by Ekotrope users.Ekotrope distUirns all liablifty for the information shown on this report, RE NET HOME ENERGY HIS RATING Standard Disclosure HERS For home(s) located at: 117 {lander Drive #41b, Northampton, MA Check the applicable disclosure(s): Sel. The Rater or the Raters employer is receiving a fee for providing the rating on this home, Z In addition to the rating, the Rater or the Raters employer has also provided the following consulting services for this home: A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself D. Training for sales or construction personnel 4, E. Other(specify) 3. The Rater or the Rater's employer is: L-4 A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C.An employee, contractor, or consultant of the electric and/or natural gas utility serving this home '*:--1'4.The Rater or Rater's employer is a supplier or installer of products, which may include: Products Installed in this home by OR is in the business of J-' HVAC systems Rater Employer :[]Rater '-lEmployer Thermal insulation systems Rater DEmployer jRater 01 Employer ,Air sealing of envelope or duct systems Rater TjEmployer E]Rater DEmployer Energy efficient appliances �7-111 mployer Rater Employer Rater E Construction (builder, developer, construction contractor, etc) Employer TEmployer ,:]Rater Rater Other(specify): 1---tRater Employer 2, Rater 7---!Employer This home has been verif ted under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling"of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification#: 9463452 Name: Adin Maynard Signature: Organization: HIS & HERS Energy Efficiency Digitally signed: 8/5/20 at 9:00 AM I attest that the above information is true and correct to the best of my knowledge.As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 102.1.4.6 of the standard and are posted at https://standards.resnet.us The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 117 OLANDER DR - UNIT 4B EP-2019-0754 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON Map: 31 C Lot:081 ELECTRICAL PERMIT Permit: Electrical Category: UNIT 4B-WIRE NEW HOUSE Permit# Electrical PERMISSION IS HEREBY GRANTED TO: Project# JS-2019-001579 Est.Cost: Contractor: License: Fee: $200.00 RICHARD SMART JR Journeyman Electrician 32453E Owner: SUNWOOD DEVELOPMENT CORP Applicant. RICHARD SMART JR AT. 117 OLANDER DR - UNIT 4A & 4B Applicant Address Phone Insurance 3 ISAAC BROADWAY (413) 219-5214 C- Liability, 8008030014703 HAMPDEN MA01036 ISSUED ON:5/6/2019 0:00:00 TO PERFORM THE FOLLOWING WORK: UNIT 4B - WIRE NEW HOUSE Call In Date: Date Requested Inspection Date/SignOff: Reinspect?: Trench/UG: Special Instructions x Rough X Special Instructions: Final: - 13 - 1-"l QQ SRE Called In: 25a4aad7 Signature: Fee Type:: Amount: DatePaid Electrical $200.00 5/6/2019 0:00:00 1705 212 Main Street,Phone(413)587-1244,Fax(413)587-1272-Inspector of Wires -Roger Malo 117 OLANDER DR - UNIT 4A EP-2019-0753 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON Map: 31 C Lot: 081 ELECTRICAL PERMIT Permit: Electrical Category: UNIT 4A-WIRE NEW HOUSE Permit# Electrical PERMISSION IS HEREBY GRANTED TO: Project# JS-2019-001579 Est.Cost: Contractor: License: Fee: $200.00 RICHARD SMART JR Journeyman Electrician 32453E Owner: SUNWOOD DEVELOPMENT CORP Applicant. RICHARD SMART JR AT. 117 OLANDER DR - UNIT 4A & 4B Applicant Address Phone Insurance 3 ISAAC BROADWAY (413) 219-5214 C- Liability, 8008030014703 HAMPDEN MA01036 ISSUED ON.5/6/2019 0:00:00 TO PERFORM THE FOLLOWING WORK. UNIT 4A - WIRE NEW HOUSE Call In Date: Date Requested Inspection Date/SignOff: Reinspect?: Trench/UG: Special Instructions X Rough X Special Instructions: Final: A n SRE Called In: (���" �/ \(� 110 LI53.3!T Sip-nature: Fee Type:: Amount: DatePaid Electrical $200.00 5/6/2019 0:00:00 1705 212 Main Street,Phone(413)587-1244,Fax(413)587-1272-Inspector of Wires -Roger Malo �1LQl S- Wil ', SL\ MASSACHUSETTS UNIFORM APPLICATION FOR A PERMIT TO PERFORM PLUMBING WORK 21 ` CITY(rOWN IUDIZ' WA-MQTZ)/V MA DATE PERMIT# JOBSITE ADDRESS 117 ALft&l g.. OWNER'S NAME P OWNER ADDRESS 6D W1'r q 6. TEL FAX TYPE OR OCCUPA CY TYPE COMMERCIAL El EDUCATIONAL ❑ RESIDENTIAL PRINT CLEARLY NEW: RENOVATION:❑ REPLACEMENT:❑ PLANS SUBMITTED: YES❑ NO❑ FIXTURES Z FLOOR— BSM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BATHTUB CROSS CONNECTION DEVICE DEDICATED SPECIAL WASTE SYSTEM DEDICATED GAS/OIL/SAND SYSTEM DEDICATED GREASE SYSTEM DEDICATED GRAY WATER SYSTEM DEDICATED WATER RECYCLE SYSTEM DISHWASHER DRINKING FOUNTAIN FOOD DISPOSER FLOOR/AREA DRAIN INTERCEPTOR INTERIOR Elect c,Plu bin Gas I octi KITCHEN SINKart npion. 1 .> LAVATORY ROOF DRAIN SHOWER STALL SERVICE/MOP SINK TOILET fj URINAL IML-Ull Ili 16-%0 11%01 9 WASHING MACHINE CONNECTION WATER HEATER ALL TYPES WATER PIPING OTHER INSURANCE COVERAGE: I have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL Ch.142. YES® NO ❑ IF YOU CHECKED YES,PLEASE INDICATE THE TYPE OF COVERAGE BY CHECKING THE APPROPRIATE BOX BELOW LIABILITY INSURANCE POLICY a OTHER TYPE OF INDEMNITY ❑ BOND ❑ 'I�Ly ff OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. CHECK ONE ONLY: OWNER ❑ AGENT ❑ SIGNATURE OF OWNER OR AGENT I hereby certify that all of the details and information I have submitted or entered regarding this application are t e urate tgg.,�the best f my knowledge and that all plumbing work and installations performed under the permit issued for this application will be in co Ii h all P t pr s' K7the Massachusetts State Plumbing Code and Chapter 142 of the General Laws. vU // PLUMBER'S NAME Phillip Hurteau LICENSE# 10963 SIGNATURE MP❑ JP❑ CORPORATION®# 2974 PARTNERSHIP❑# LLC❑AL- COMPANY NAME Phillip's Plumbing& Heating, Inc. ADDRESS 15 Arthur Street CITY Easthampton STATE MA ZIP 01027 TEL 413-527-0340 FAX 413-527-2406 CELL 413-626-6725 EMAIL pphl5arthur@gmail.com i ,._, 8--atm s, i. 5o ►�5 nAzzt i 'lot o o v C\ MASSACHUSETTS UNIFORM APPLICATION FO A PERMIT TO PERFORM PLUMBING WORK CITY/TOWN f D gni iA YY\p TO 110 MA DATE PERMIT#9?_j , _ JOBSITEADDRESS 1.17 DRI_P N Q EP_ D R_ _ OWNER'S NAME _g0(VW0Q1D -Bi-M-5 P OWNER ADD SS_ LAU L7' '18 TEL FAX TYPE OR OCCUPA TYPE COMMERCIAL❑ EDUCATIONAL ❑ RESIDENTIAL[ PRINT CLEARLY NEW: RENOVATION:❑ REPLACEMENT:❑ PLANS SUBMITTED: YES❑ NO❑. FIXTURES Z FLOOR- 85M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BATHTUB CROSS CONNECTION DEVICE DEDICATED SPECIAL WASTE SYSTEM DEDICATED GAS/OIUSAND SYSTEM DEDICATED GREASE SYSTEM Liz DEDICATED GRAY WATER SYSTEM DEDICATED WATER RECYCLE SYSTEM DISHWASHER ti DRINKING FOUNTAIN FOOD DISPOSER FLOOR/AREA DRAIN I Li INTERCEPTOR INTERIOR Eieci ric, MA 0 Oso KITCHEN SINK LAVATORY ROOF DRAIN SHOWER STALL SERVICE/MOP SINK • - TOILET ' _ URINAL WASHING MACHINE CONNECTION WATER HEATER ALL TYPES WATER PIPING OTHER INSURANCE COVERAGE: I have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL Ch.142. YES® NO ❑ IF YOU CHECKED YES,PLEASE INDICATE THE TYPE OF COVERAGE BY CHECKING THE APPROPRIATE BOX BELOW LIABILITY INSURANCE POLICY OTHER TYPE OF INDEMNITY ❑ BOND ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement.- CHECK ONE ONLY: OWNER ❑ AGENT ❑ SIGNATURE OF OWNER OR AGENT • I hereby certify that all of the details and information I have submitted or entered regarding this application are t a a rate#o a best of y knowledge and that all plumbing work and installations performed under the permit issued for this application will be in com all P ' e t provi on Massachusetts State Plumbing Code and Chapter 142 of the General Laws. PLUMBER'S NAME Phillip Hurteau LICENSE#. 10963 IGN TURE MP❑ JP❑ CORPORATION®# 2974 PARTNERSHIP❑# LLC❑# COMPANY NAME Phillip's Plumbing&Heating, Inc. ADDRESS 15 Arthur Street CITY Easthampton STATE MA Zip 01027 TEL 413-527-0340 FAX 413-527-2406 CELL 413-626-6725 EMAIL pphl5arthur@gmail.com j _-jf zr� !i 51 9 ' �