Loading...
2 Conz St revised 2020-02-27LIST OF DRAWINGS DRAWING ISSUED = ● REISSUED WITH REVISION = ○ REISSUED WITHOUT REVISION = ◌ISSUED FOR BID10/10/19Release Issue 2 --/--/--Release Issue 3 --/--/--Release Issue 4 --/--/--Release Issue 5 --/--/--Release Issue 6 --/--/--Release Issue 7 --/--/--Release Issue 8 --/--/--Release Issue 9 --/--/--GENERAL G 100 COVER SHEET ● G 101 GENERAL NOTES & SPECIFICATIONS ● GENERAL CONDITIONS GC 200 IBC CODE REVIEW GC 201 EGRESS FLOOR PLANS ● DEMOLITION AD 100 DEMOLITION FLOOR PLANS & NOTES ● AD 200 DEMOLITION REFLECTED CEILING PLANS ● ARCHITECTURAL A 001 STRUCTURAL GENERAL NOTES ● A 002 GENERAL STRUCTURAL DETAILS ● A 100 FOUNDATION PLAN, NOTES, & DETAILS ● A 101 FRAMING PLANS, NOTES, & DETAILS ● A 102 CONSTRUCTION FLOOR PLANS & NOTES ● A 103 PARTITION SCHEDULE & PLAN DETAILS ● A 200 REFLECTED CEILING PLANS, NOTES, & LEGENDS ● A 300 EXTERIOR ELEVATIONS & NOTES ● A 400 BUILDING SECTIONS AND DETAILS ● A 401 ENLARGED STAIR PLANS AND SECTION ● A 402 ENLARGED STAIR SECTION & DETAILS ● A 500 ENLARGED PLANS & ELEVATIONS ● A 700 DOOR, WINDOW, & HARDWARE SCHEDULES ● INTERIORS I 100 FINISH FLOOR PLANS, SCHEDULES, NOTES, & DETAILS ● I 101 FINISH SPECIFICATIONS & NOTES ● I 102 FLOOR PATTERNS ● I 300 ENLARGED MILLWORK PLANS & ELEVATIONS ● I 301 ENLARGED MILLWORK PLANS & ELEVATIONS ● I 302 ENLARGED MILLWORK PLANS & ELEVATIONS ● 1 303 MILLWORK DETAILS I 400 FURNITURE & EQUIPMENT PLANS I 500 SIGNAGE ● ABBREVIATIONSDRAWING LEGEND 1 A 100 1i Name EL.=Elevation± A101 1 Room name 101 101 ? ? A101 1 1 1A B 1C D 1 A 1 DEMOLITION U.N.O. NEW CONSTRUCTION EXISTING TO REMAIN PARTITION TYPE ELEVATION DETAIL EXTERIOR ELEVATION INTERIOR ELEVATION 1 A101 SECTION 1 ROOM NUMBER DOOR NUMBER WINDOW TYPE INTERIOR FINISH TYPE GRID LINE REVISION NO. AND REVISION CLOUD EXTERIOR FINISH TYPE KEY PLAN OWNER NORTHEMPTON, LLC 2131 WASHINGTON STREET BOSTON, MA 02119 JON NAPOLI OWNER BOSTONGARDENER@GMAIL.COM 617-816-7067 GENERAL CONTRACTOR TBD . . TBD . . . ARCHITECT BKA ARCHITECTS, INC 142 CRESCENT ST. BROCKTON, MA 02302 JILL PEEBLES ARCHITECT jpeebles@bkaarchs.com 508-583-5603 STRUCTURAL ENGINEER FLOOD ENGINEERING 56 LAUREL DRIVE HUDSON, MA 01749 STACY FLOOD PRINCIPAL SRFLOOD@VERIZON.NET 978-562-6246 PROJECT DIRECTORYLOCUS PLAN ACP ACOUSTIC CEILING PANEL ADDTL ADDITIONAL AFF ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION ADJ ADJUSTABLE ALT ALTERNATE ALUM ALUMINUM BO BOTTOM OF BOH BOARD OF HEALTH BLDG BUILDING CL CENTER LINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS DAFS DIRECTLY APPLIED FINISH SYSTEM DF DRINKING FOUNTAIN D/B DESIGN BUILD DIM DIMENSION DWG DRAWING ETR EXISTING TO REMAIN ENG ENGINEER ENG'D ENGINEERED EXIST EXISTING EXT EXTERIOR FD FLOOR DRAIN FO FINISHED OPENING FRGWB FIRE RATED GYPSUM WALL BOARD FS FRAME SIZE FIN FINISH FLR FLOOR FNDN FOUNDATION GA GAUGE GC GENERAL CONTRACTOR GWB GYPSUM WALLBOARD GYP GYPSUM HR HOUR INSUL INSULATED INT INTERIOR MO MASONRY OPENING MRGWB MOISTURE RESISTANT GYPSUM WALL BOARD MAX MAXIMUM MFGR'S MANUFACTURER'S MIN MINIMUM MIRR MIRROR MTD MOUNTED MTL METAL NTS NOT TO SCALE N/A NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER OAE OR APPROVED EQUAL OC ON CENTER OF OUTSIDE FACE OFCI OWNER FURNISHED CONTRACTOR INSTALLED OPP OPPOSITE P-LAM PLASTIC LAMINATE PR PATCH AND REPAIR PREP PREPARE PTD PAINTED RO ROUGH OPENING REQ'D REQUIRED REV REVISION(S) OR REVISED SA SOUND ATTENUATING SIM SIMILAR SPEC SPECIFICATIONS STRUCT STRUCTURAL SUB-C SUBCONTRACTOR TME TO MATCH EXISTING TO TOP OF TELE TELEPHONE TEMP TEMPERED TYP TYPCAL UL UNDERWRITERS LABORATORIES UNO UNLESS NOTED OTHERWISE US UNDERSIDE VIF VERIFY IN FIELD W/WITH HEMPEST DISPENSARY 2 CONZ STREET BID SET - 10/10/19 NORTHAMPTON, MA 01067 HEMPEST DISPENSARY HEMPEST DISPENSARY CHECKER DRAFTER Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_G-100 COVER SHEET.dwgLast save: Oct 10, 2019 - 3:29pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID G 100 COVER SHEET GENERAL NOTES: THE GENERAL CONTRACTOR SHALL CONFORM TO AIA DOCUMENT A201 - (2017) GENERAL CONDITIONS. IT IS HEREBY MADE PART OF THIS CONTRACT HEREIN: 1.THE GENERAL CONTRACTOR (G.C.) SHALL FIELD VERIFY ALL DIMENSIONS & CONDITIONS PRIOR TO THE WORK AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT REGARDING ANY DISCREPANCIES. NO WORK SHALL PROCEED UNTIL SUCH DISCREPANCY HAS BEEN RECTIFIED. 2.THE G.C. AND THE DESIGN/BUILD (D/B) SUBCONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING COMPLETE M.E.P. SYSTEMS DESIGN AND LAYOUT DRAWINGS WITH CALCULATIONS & LOADS (AS MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION) WHICH CONFORM TO ALL STATE AND LOCAL CODES, STAMPED AND CERTIFIED BY A REGISTERED P.E. AS REQUIRED BY THE M.S.B.C. & THE LOCAL BUILDING & FIRE DEPTS. AT THE TIME OF PERMIT. THIS INCLUDES ANY DESIGN & INSPECTION AFFIDAVITS ENERGY CONSERVATION DATA AND NARRATIVES AS REQUIRED PER 2015 IBC, 2015 IECC AND THE AMENDMENTS TO CHAPTER 13 OF THE MASSACHUSETTS STATE BUILDING CODE (M.S.B.C.), NINTH EDITION. 3.THE G.C. SHALL SEAL ALL THROUGH-WALL & FLOOR PENETRATIONS WITH 3M BARRIER CAULK AND SEALANT ON USG SAFING- 2500 PSI GROUT @ CMU. INSTALL ANY REQUIRED FIRE RATED PARTITIONS TO UNDERSIDE OF FLOOR OR ROOF DECK INCLUDING DEFLECTION HEAD. 4.THE G.C. SHALL BE RESPONSIBLE FOR DAILY REMOVAL AND LEGAL DISPOSAL OF ALL DEBRIS. 5.THE G.C. SHALL BE RESPONSIBLE FOR ALL PERMITS, AND FEES AS REQUIRED BY THE LOCAL MUNICIPALITY OR UTILITIES 6.THE DRAWINGS ARE NOT TO BE SCALED. ALL WORK, LINES AND LEVELS SHALL BE LAID OUT BY WRITTEN DIMENSIONS. GWB DIMENSIONS ARE FROM FACE TO FACE OF FINISH. ANY DEVIATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. ALL DEVIATIONS SHALL BE CORRECTED BY THE CONTRACTOR BEFORE HE BEGINS HIS PORTION OF THE WORK. 7.INSTALL A CONTINUOUS SEALANT BEAD ON BACKER ROD AT ALL JUNCTURES OF DISSIMILAR MATERIALS (E.G.: METAL TO CMU, STEEL TO ALUMINUM) AND ALL MATERIAL JOINTS AS REQUIRED BY THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS, INDUSTRY STANDARDS AND GOOD PRACTICE. 8.COORDINATE SOLID BLOCKING FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES PER 521 CMR MAAB AND ADAAG (WHERE MORE RESTRICTIVE) AS DEFINED FOR STRUCTURAL STRENGTH. 9.PROVIDE CONTINUOUS GALVANIZED METAL EDGE TRIM AT ALL GWB WORK. 10.THE G.C. SHALL SUBMIT ALL SHOP DRAWINGS, SAMPLES, CATALOG CUTS ETC., INCLUDING COLOR CHARTS FOR PAINTS AND STAINS FOR ALL EXTERIOR AND INTERIOR FINISHES, TO THE ARCHITECT & OWNER FOR SELECTION, REVIEW AND APPROVAL PRIOR TO ORDERING, FABRICATION OR INSTALLATION. 11.ALL PARTIES SHALL BE RESPONSIBLE FOR CONFORMING TO 2015 IBC AND AMENDMENTS TO THE M.S.B.C. SECTION 107.6 FOR CONSTRUCTION CONTROL. 12.THE G.C. AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE ENGINEERING DESIGN LAYOUT AND INSTALLATION FOR ANY EXTERIOR COLD-FORMED METAL FRAMING AS PER MSBC. METAL STUDS SHALL BE INSTALLED AS REQUIRED TO SUIT FIELD CONDITIONS. BRACE AS REQUIRED BY MSBC CH.16 AND FIELD CONDITIONS. PROVIDE SEALED AND SIGNED ENGINEERED SHOP DRAWINGS & CALCULATIONS INDICATING MATERIAL CHARACTERISTICS, DETAILS OF CONSTRUCTION, CONNECTIONS, AND RELATIONSHIPS W/ADJACENT CONSTRUCTION- TYP. BY A MASSACHUSETTS STATE REGISTERED P.E. 13.INSTALL USG .093 (OR APPROVED EQUAL) CONTROL JOINTS @ 30'-0" O.C. MAX. OR AS PER MANUFACTURER'S SUGGESTED DETAILS AND SPECIFICATIONS. 14.PERFORM ALL WORK IN ACCORDANCE WITH THE M.S.B.C. AND ADAAG (WHERE MORE RESTRICTIVE), AS WELL AS ALL LOCAL BY-LAWS, ORDINANCES AND FIRE STATUTES. 15.THE G.C. SHALL INSTALL ALL INTERIOR FINISHES AT ALL SURFACES INDICATED ON THE DRAWINGS IN CONFORMANCE TO M.S.B.C. TABLE 803.11 & SECTION 804. 16.THE G.C. SHALL INSTALL ALL DOORS HAVING LEVER HARDWARE TO CONFORM TO 521 CMR, MAAB & ADAAG (WHERE MORE RESTRICTIVE). 17.THE G.C. SHALL COORDINATE WITH THE D/B SUB-CONTRACTORS AND PROVIDE ANY ACCESS PANELS REQUIRED BY CODE AND AS REQUESTED BY THE OWNER & TENANT. MECHANICAL NOTES 1.THE D/B HVAC SUB-C SHALL BE RESPONSIBLE FOR PROVIDING ENGINEERING DESIGN DRAWINGS, LAYOUT, SHOP DRAWING SUBMITTALS AND INSTALLATION FOR SUPPLY, RETURN, MAKE-UP AIR & EXHAUST SYSTEMS & CONTROL WIRING, DEVICES & EQUIP. AS REQUIRED BY THE LATEST EDITION OF THE INTERNATIONAL MECHANICAL CODE 2015 M.S.B.C. CHAPTER 13, AS AMENDED FOR ENERGY CONSERVATION. WORK SHALL CONFORM TO LATEST SMACNA & ASHRAE STANDARDS. 2.THE DESIGN/BUILD HVAC SUB-C. SHALL BE RESPONSIBLE FOR CONFORMING TO CH. 13 IBC AS AMENDED BY MASSACHUSETTS AND 2015 IMC, SECTION 106.3, INCLUDING ALL SEALED AND SIGNED CALCULATIONS AND NARRATIVES. 3.G.C. AND D/B HVAC SUBCONTRACTOR TO COORDINATE WITH TENANT & TENANT'S VENDORS PRIOR TO COMPLETING ENGINEERED DESIGN DRAWINGS. PLUMBING NOTES 1.D/B PLUMBING SUBCONTRACTOR SHALL CONFORM TO ALL STATE CODES, LOCAL CODES, MASS. STATE FUEL GAS & PLUMBING CODE (CMR 248) FOR ALL WORK. ELECTRICAL NOTES 1.THE D/B ELECTRICAL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE ELECTRICAL ENGINEERING DESIGN (AS MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION) LAYOUT, SHOP DRAWING SUBMITTALS, AND INSTALLATION TO SUIT THE WORK. INCLUDING 2015 IECC REQUIREMENTS FOR SECTION 405 POWER DISTRIBUTIONS AND LIGHTING SYSTEMS: HE/SHE SHALL COORDINATE POWER WIRING AND CABLING, LIGHTING, DEVICES, EQUIPMENT, RUNS, TERMINATIONS, CIRCUITS AND PANEL LOCATION. COORDINATE ANY SPECIAL ELECTRICAL DEVICES OR EQUIPMENT REQUIREMENTS WITH THE OWNER PRIOR TO WORK. 2.G.C. TO COORDINATE WITH D/B FIRE ALARM SUB-CONTRACTOR TO LOCATE AND PROVIDE EMERGENCY LIGHTING, EXIT SIGNS AND EXIT LIGHTS AS PER M.S.B.C. SECTION 1008 & 1013 G.C. TO COORDINATE LOCATIONS & SPECIFICATIONS WITH ARCHITECT PRIOR TO COMMENCING WITH THE WORK. 3.THE G.C. AND D/B ELECTRICAL SUBCONTRACTOR SHALL REVIEW LIGHT FIXTURE CUTS & SPECIFICATIONS WITH ARCHITECT AND OWNER PRIOR TO ORDERING AND PRIOR TO THE WORK. 4.THE G.C. SHALL COORDINATE THE WORK OF ALL TRADES REGARDING CEILING-MOUNTED AND ABOVE-CEILING-MOUNTED EQUIPMENT, DEVICES AND FIXTURES. 5.THE ELECTRICAL D/B SUBCONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMING TO THE UPGRADES TO NEC & MEC, LATEST EDITIONS, FOR ALL ELECTRICAL WORK. 6.COORDINATE MASTER BOX, KNOX BOX, AND BEACON LOCATIONS WITH THE D/B ELECTRICAL/FIRE ALARM DRAWINGS AND THE CITY OF NORTHAMPTON FIRE DEPARTMENT REQUIREMENTS. 7.D/B ELECTRICAL SUBCONTRACTOR TO PROVIDE D/B ENGINEERED FIRE ALARM DRAWINGS AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. D/B ELECTRICAL SUBCONTRACTOR TO COORDINATE WITH OWNER. PROVIDE AND INSTALL A COMPLETE FIRE ALARM SYSTEM AS APPROVED BY THE CITY OF NORTHAMPTON FIRE MARSHALL. MISCELLANEOUS: 1.G.C. TO COORDINATE THE ARCHITECTURAL, EXISTING STRUCTURAL & EXISTING FIELD CONDITIONS W/ THE D/B FIRE PROTECTION, PLUMBING, MECHANICAL, FIRE ALARM, & ELECTRICAL DWGS. FOR VERIFICATION OF ALL PROJECT REQUIREMENTS. DEMOLITION SPECIFICATIONS: 1.GENERAL 1.A.SUBMIT FOR APPROVAL SELECTIVE DEMOLITION SCHEDULE, INCLUDING SCHEDULE AND METHODS FOR CAPPING AND CONTINUING UTILITY SERVICES. 1.B.USE ADEQUATE NUMBERS OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE OF THE WORK OF THIS SECTION. 1.C.ALL WORK SHALL COMPLY WITH THE RULES AND REGULATIONS OF THE DIVISION OF INDUSTRIAL SAFETY, OSHA, 29 CMR 10 AND ALL OTHER LOCAL, STATE AND FEDERAL AGENCIES AND AUTHORITIES HAVING JURISDICTION. 1.D.THE DEMOLITION CONTRACTOR SHALL COORDINATE AND BE RESPONSIBLE FOR ALL CITY OF NORTHAMPTON & MASSACHUSETTS STATE REQUIREMENTS FOR PROTECTION OF PERSONS, PROPERTY, TRAFFIC, CONTROL, BARRICADES, TEMP. LIGHTING, ETC. FOR THE DURATION OF THE DEMOLITION CONTRACT. 1.E.GENERAL CONTRACTOR TO PROVIDE AND COORDINATE A SCHEDULE FOR DEMOLITION WITH SPECIFIC ITEMS TO CONFORM WITH SCHEDULING FOR OTHER TRADES REQUIRED TO COMPLETE OR PERFORM A DIRECTLY RELATED PORTION OF WORK. THE G.C. SHALL COORDINATE WITH OWNER AND ABUTTERS REGARDING DEMOLITION, NOISE, INTRUSIVE LIGHTING, ETC. PRIOR TO CONSTRUCTION AT A PRE-CONSTRUCTION CONFERENCE. 1.F.G.C. TO VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION 1.G.G.C. TO DEMOLISH ALL ITEMS INDICATED DASHED. REPORT TO ARCHITECT ANY DISCREPANCIES PRIOR TO DEMOLITION. 2.HANDLING 2.A.WHEN THE NATURE OF DEMOLITION WORK REQUIRES THEIR USE, ERECT AND MAINTAIN DUST CHUTES & BARRIERS FOR THE DISPOSAL OF MATERIALS, RUBBISH, AND DEBRIS. 2.B.REMOVE AND SALVAGE DEBRIS FROM THE SITE AS IT ACCUMULATES ON A DAILY BASIS. DO NOT STORE, SELL, BURN, OR OTHERWISE DISPOSE OF DEBRIS ON THE SITE. REMOVE ALL MATERIALS IN SUCH A MANNER AS TO PREVENT SPILLAGE. KEEP ALL PAVEMENTS AND AREAS ADJACENT TO AND LEADING FROM THE SITE, CLEAN AND FREE OF MUD, DIRT, AND DEBRIS AT ALL TIMES. ALL MATERIALS SHALL BE DISPOSED OF IN A LEGAL MANNER OFF-SITE. 2.C.ERECT AND MAINTAIN TEMPORARY BRACING, SHORING, LIGHTS, PARTITIONS, BARRICADES, WARNING SIGNS, LIGHTS, AND GUARDS NECESSARY TO PROTECT ADJACENT BUILDING OCCUPANTS, AND WORKERS FROM INJURY, AND/OR DAMAGE, ALL IN ACCORDANCE WITH APPLICABLE RULES AND REGULATIONS. 2.D.DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATED TO REMAIN. ITEMS OF SALVAGE VALUE WHICH ARE NOT INCLUDED ON SCHEDULE OF SALVAGE ITEMS TO BE RETURNED TO OWNER SHALL BE REVIEWED WITH OWNER AS TO WHETHER THEY CAN BE REMOVED FROM THE PREMISES. STORAGE OR SALE OF ITEMS AT PROJECT SITE IS PROHIBITED. DEMOLISHED MATERIAL SHALL BE COMPLETELY REMOVED FROM THE SITE AND DISPOSED OF USING LEGAL METHODS. 2.E.DO NOT CLOSE OR OBSTRUCT THE MEANS OF EGRESS, CORRIDORS, OR OTHER OCCUPIED SPACES. REVIEW ANY SEQUENCE OR PHASING ISSUES W/ BKA ARCHITECTS, OWNER, TENANT, AND CITY OF NORTHAMPTON PROJECT REPRESENTATIVE. DO NOT INTERRUPT UTILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER OR AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES. 2.F.CEASE OPERATIONS IF PUBLIC SAFETY OR REMAINING STRUCTURES ARE ENDANGERED. PERFORM TEMPORARY CORRECTIVE MEASURES UNTIL OPERATIONS CAN BE CONTINUED PROPERLY. 3.SEQUENCING AND EXECUTION 3.A.AFTER CAREFUL STUDY OF THE CONTRACT DOCUMENTS, DETERMINE THE LOCATION AND EXTENT OF SELECTIVE DEMOLITION TO BE PERFORMED. 3.B.VISIT THE SITE AND VERIFY THE EXTENT AND LOCATION OF SELECTIVE DEMOLITION REQUIRED PRIOR TO STARTING THE WORK. 3.B.1.CAREFULLY IDENTIFY LIMITS OF SELECTIVE DEMOLITION. 3.B.2.MARK INTERFACE SURFACES AS REQUIRED TO ENABLE WORKMAN TO ALSO IDENTIFY ITEMS TO BE REMOVED, ITEMS TO BE LEFT IN PLACE INTACT, ITEMS TO BE SALVAGED AND/OR FOR REUSE AND RELOCATION, AND ITEMS TO BE REMOVED AND SORTED FOR RECYCLING. 3.C.PREPARE AND FOLLOW AN ORGANIZED PLAN FOR DEMOLITION AND REMOVAL OF ITEMS. 3.C.1.SHUT OFF, CAP, AND OTHERWISE PROTECT EXISTING UTILITY LINES IN ACCORDANCE WITH THE REQUIREMENTS OF THE PUBLIC AGENCY OR UTILITY HAVING JURISDICTION. NOTIFY DIG-SAFE AND CITY OF NORTHAMPTON PRIOR TO EXCAVATION. 3.C.2.COMPLETELY REMOVED ITEMS SCHEDULED TO BE SO DEMOLISHED AND REMOVED, LEAVING SURFACES CLEAN, SOLID, AND READY TO RECEIVE NEW MATERIALS SPECIFIED ELSEWHERE. IN ALL ACTIVITIES, COMPLY WITH PERTINENT REGULATIONS & GOVERNMENTAL AGENCIES HAVING JURISDICTION. 3.D.USE MEANS NECESSARY TO PREVENT DUST BECOMING A NUISANCE TO WORKERS IN THE BUILDING, THE PUBLIC, NEIGHBORING BUILDINGS, AND TO OTHER WORK BEING PERFORMED. 3.E.SCHEDULE & EXECUTE DEMOLITION WORK TO ENSURE SAFETY OF PERSONS AND ADJACENT PROPERTY AGAINST DAMAGE BY WIND-BLOWN OR FALLING DEBRIS. 3.F.IN THE EVENT DEMOLITION OF ITEMS NOT SO SCHEDULED TO BE DEMOLISHED, PROMPTLY REPLACE SUCH ITEMS TO THE APPROVAL OF THE ARCHITECT AT NO ADDITIONAL INCREASE IN COST OR TIME TO THE OWNER. 3.G.WHERE EXISTING CONSTRUCTION TO REMAIN IS AFFECTED BY DEMOLITION OR INSTALLATION OF NEW WORK, PATCH, REPAIR OR REPLACE THE WORK AT SURFACES WHICH HAVE BEEN DAMAGED AND FINISH TO MATCH EXISTING (T.M.E.) ADJACENT CONSTRUCTION. 3.H.FINISH NEW AND EXISTING SURFACES AS SCHEDULED. CLEAN EXISTING SURFACES OF DIRT, GREASE, AND LOOSE PAINT BEFORE REFINISHING. 3.I.COORDINATE THE REMOVAL, RELOCATION, REPLACEMENT, RE-USE, SHUT-OFF, STUB-OFF, CAPPING-OFF, OR UPGRADING OF ALL EXISTING, PLUMBING, HVAC, FIRE PROTECTION, FIRE ALARM, SECURITY AND ELECTRICAL SYSTEMS, EQUIPMENT, AND APPURTENANCES - INCLUDING, BUT NOT LIMITED TO, UTILITY LINES, DUCTS, CONNECTIONS, PANELS, VENTS, FANS, PIPING, DEVICES, CONTROLS, OUTLETS, AND CONDUIT DURING CONSTRUCTION AS REQUIRED, AS SCHEDULED, OR AS SPECIFIED IN ACCORDANCE WITH ALL LOCAL, MUNICIPAL AND STATE CODES TO SUIT THE WORK. 4.SCOPE 4.A.ITEMS TO BE SALVAGED FOR REUSE OR TO BE SORTED FOR RECYCLING: 4.A.1.G.C. TO SALVAGE, STORE AND PROTECT EXISTING TIN CEILING PANELS IN EXISTING HEMPEST TENANT SPACE FOR RE-USE IN NEW TENANT SPACE. ARCHITECT TO INSPECT AND SELECT PANELS FROM SALVAGED MATERIAL FOR RE-USE. 4.A.2.ALL METAL PRODUCTS, INCLUDING BUT NOT LIMITED TO, MISCELLANEOUS METALS, ORNAMENTAL METALWORK, METAL DOORS AND FRAMES, STRUCTURAL STEEL, PLEXIGLASS, ALL UNDAMAGED ACOUSTICAL CEILING PANELS & DUCTWORK. 4.A.3.MEP ITEMS PER D/B CONTRACTOR. ALL ALUMINUM PRODUCTS, INCLUDING BUT NOT LIMITED TO ALUMINUM DOORS, FRAMES, AND DUCTWORK. 4.A.4.CARPET, REFER TO MANUFACTURERS RECYCLING METHODS & REQUIREMENTS FOR PICKUP. 4.A.5.ANY OTHER ITEMS DEEMED RECYCLABLE BY THE G.C., OWNER, TENANT, OR ARCHITECT PRIOR TO THE START OF DEMOLITION. 4.B.REMOVAL OF HAZARDOUS MATERIALS: 4.B.1.IN THE EVENT THAT HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION WHICH HAVE NOT BEEN RENDERED HARMLESS, THE G.C. SHALL IMMEDIATELY STOP WORK IN THE AREA AFFECTED AND REPORT THE CONDITION TO THE OWNER AND ARCHITECT IN WRITING. WORK SHALL NOT BE RESUMED UNTIL THE MATERIAL IS RENDERED HARMLESS. 4.B.2.G.C. SHALL FORWARD ALL TESTING REPORTS AND DOCUMENTATION INDICATING REMOVAL OF HAZARDOUS MATERIALS TO OWNER AND ARCHITECT. CONSTRUCTION NOTES: 1.USE NO COMBUSTIBLE MATERIALS OVER SUSPENDED CEILINGS. FIRE RETARDANT TREATMENTS WILL BE EXTENDED TO STRUCTURAL CEILING WHEREVER REQUIRED FOR COMPLIANCE WITH CODE REQUIREMENTS. 2.USE MINIMUM 20 GAUGE METAL STUDS OR 7/8" METAL FURRING CHANNELS, TYPE AND SPACING IN ACCORDANCE WITH LOCAL BUILDING REQUIREMENTS, NORMAL SPACING OF 16" O.C., FOR FRAMING PARTITIONS AND SIMILAR CONSTRUCTION, U.N.O. 3.WOOD DOORS AND FRAMES SHALL MEET ALL APPLICABLE REQUIREMENTS OF THE AMERICAN WOODWORK INSTITUTE "QUALITY STANDARDS" AND "NATIONAL WOODWORK MANUFACTURERS ASSOCIATION" SPECIFICATION UNLESS OTHERWISE SPECIFIED. 4.GYPSUM BOARD SHALL BE 5/8" THICK AND SHALL BE MOISTURE AND WATER RESISTANT GRADE IN ALL WET AREAS, INCLUDING TOILET ROOMS. 5.ALL DIMENSIONS TO AND FROM NEW PARTITIONS ARE FACE OF GYPSUM TO FACE OF GYPSUM, UNLESS OTHERWISE NOTED. 6.ALL DIMENSIONS TO AND FROM EXISTING WALLS ARE FROM FACE OF EXISTING FINISH TO FACE OF EXISTING FINISH, UNLESS OTHERWISE NOTED. 5.SEE G201 AND D/B SUB DRAWINGS FOR PATH OF EGRESS AND FIRE ALARM PLAN. 6.UNLESS NOTIFIED OR STATED TO THE CONTRARY, THE G.C. IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS. THE G.C. IS RESPONSIBLE FOR THE PICK-UP OF THE PERMIT AND ALL ASSOCIATED FEES. G.C. IS RESPONSIBLE FOR ALL INSPECTIONS AND APPROVALS NEEDED TO MEET ALL APPLICABLE CODES. 7.WHERE REQUIRED BY LOCAL JURISDICTIONS IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL, PLUMBING, SPRINKLER, & FIRE ALARM SUB-CONTRACTORS, TO OBTAIN ALL NECESSARY PERMITS & ALL ASSOCIATED FEES FOR THEIR PERMITS RESPECTIVELY. THIS INCLUDES ANY EXPEDITED FEES NECESSARY TO OBTAIN SUCH PERMITS. 8.THE CONTRACTOR SHALL SCHEDULE AND COORDINATE WITH THE TENANT, THROUGH HIS AUTHORIZED REPRESENTATIVE, ALL WORK WHICH MAY CAUSE INTERRUPTION TO THE EXISTING MECHANICAL, ELECTRICAL SYSTEM, OR BUILDING OPERATIONS. ADVANCED NOTICE SHALL ALSO BE GIVEN TO THE OWNER'S & TENANT'S REPRESENTATIVE FOR ANY WORK WHICH WILL INTERFERE WITH THE FIRE SAFETY AND SECURITY SYSTEMS WITHIN THE BUILDING. 9.THE CONTRACTOR SHALL NOT DETAIL, ORDER, AND/OR FABRICATE ANY MATERIAL WITHOUT COORDINATING SAME WITH THE ACTUAL FIELD CONDITIONS. THE CONTRACTOR ALONE IS RESPONSIBLE FOR THE PROPER FITTING AND CONNECTION OF THE NEW CONSTRUCTION TO THE EXISTING CONSTRUCTION. 10.ALL FIREPROOFING OR SEALANTS THAT ARE DAMAGED AS A RESULT OF WORK SHALL BE PATCHED WITH MATERIALS AND THICKNESS TO MATCH EXISTING. 11.THE CONTRACTOR SHALL ACCEPT AND UNLOAD DELIVERY OF ALL FURNISHED CONSTRUCTION MATERIALS, EQUIPMENT, AND FIXTURES. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS ONCE DELIVERED. UPON ARRIVAL, CONTRACTOR MUST CHECK THE CONDITION AND QUANTITIES OF THE MATERIALS DELIVERED. 12.THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND SEE THAT ALL CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF ALL MATERIALS BY ALL TRADES IS PROPERLY EXECUTED AS DESCRIBED WITHIN THIS SCOPE OF WORK SHOWN ON THE DRAWINGS OR ISSUED DOCUMENTS. 13.THE CONTRACTOR SHALL COORDINATE WITH THE OWNER & TENANT THE AREAS OF THE SITE FOR DELIVERY & STORAGE OF MATERIAL. 14.ALL MATERIALS AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF ALL APPLICABLE BUILDING, ELECTRICAL, SAFETY AND SANITARY LAWS ENFORCED IN THE STATE AND CITY WHERE THIS PROJECT IS LOCATED. THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR ANY VIOLATION OF THE SAME AND SHALL MAKE ALL WORK ACCEPTABLE TO THE PUBLIC DEPARTMENT INVOLVED WITHOUT EXTRA CHARGE. 15.THE GENERAL CONTRACTOR AND SUPPLIERS OF LABOR AND MATERIALS SHALL PROVIDE A ONE (1) YEAR GUARANTEE ON ALL WORK AND MATERIALS FROM THE DATE OF SUBSTANTIAL COMPLETION AND COMPLETION OF ALL PUNCH LIST ITEMS TO THE COMPLETE SATISFACTION OF THE OWNER. 16.THE GENERAL CONTRACTOR AND SUPPLIERS OF LABOR AND MATERIALS SHALL ABIDE BY ALL THE BUILDING RULES AS SUPPLIED BY BUILDING OWNER & TENANT. 17.INITIATION OF WORK BY THE CONTRACTOR REPRESENTS THAT THE GENERAL CONTRACTOR AND DEMOLITION CONTRACTOR VISITED THE SITE PRIOR TO BIDDING, ARE FAMILIAR WITH THE SITE CONDITIONS AND INCORPORATED THE CONDITIONS INTO THE SCOPE OF WORK. 18.PROVIDE DIAGONAL BRACING TO STRUCTURE ABOVE ALL DOORS, GLAZING HEADS AND JAMBS AS REQUIRED TO MAKE ASSEMBLY RIGID. 19.CONTRACTOR IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF RATED PARTITIONS & STRUCTURE PARTICULARLY WHERE PENETRATED BY VARIOUS TRADES AND SERVICES. 20.THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE FINAL CLEAN UP OF THE ENTIRE PREMISES TO INCLUDE BUT NOT LIMITED TO FLOORS, MILLWORK, FIXTURES, ETC. FOLLOWING THE INSTALLATION OF THE EQUIPMENT & O.F.C.I. ITEMS. 21.G.C. SHALL COORDINATE, SUPPLY & INSTALL PROPER AND ADEQUATE ANCHORS, FURRING, BLOCKING, STUDS, AND SIMILAR PROVISIONS TO SUPPORT ALL MILLWORK & SHELVING FIXTURES OR RACK SYSTEMS (INCLUDING TENANT OR OWNER PROVIDED ITEMS) & CONTRACTOR ITEMS, FOR A FIRM, SECURE, AND CONCEALED SUPPORT OR ATTACHMENT OF WALL OR COLUMN FIXTURES, LIGHTING FIXTURES, TOILET ROOM ACCESSORIES, AND SERVICE FACILITIES AT LOCATIONS INDICATED BY PLANS AND/OR ELEVATIONS AND/OR DETAILS. GC SHALL COORDINATE WITH MILLWORK CONTRACTOR FOR REQUIRED LOCATIONS AND ADEQUACY OF BLOCKING REQUIREMENTS AND PROVIDE ALL SUCH BLOCKING PRIOR TO CLOSING UP ANY AND ALL WALLS, PARTITIONS, COLUMNS, ETC. IF REQUIRED BY CODE AND LOCAL BUILDING OFFICIAL, WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED TO MEET SUCH REQUIREMENT AS NEEDED. 22.G.C. SHALL COORDINATE WITH THE FIRE ALARM D/B SUB-CONTRACTOR FOR THE INSTALLATION OF ANY FIRE ALARM SYSTEM REQUIRED BY THE LOCAL FIRE MARSHALL OR FIRE DEPARTMENT OFFICIAL. 23.ANY & ALL PENETRATIONS THROUGH FIRE-RATED ASSEMBLIES SHALL BE FILLED, TAPED, SEALED, ETC. USING FIRE PROTECTION MATERIAL IN ACCORDANCE WITH ANY OR ALL LOCAL, STATE, OR FEDERAL CODES. JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_G-101 GENERAL NOTES & SPECIFICATIONS.dwgLast save: Oct 10, 2019 - 2:09pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID G 101 GENERAL NOTES & SPECIFICATIONS ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) SCALE: 1 FIRST FLOOR EGRESS PLAN 1/4" = 1'-0" N DESIGN NORTH EXTERIOR EXTERIOR EXTERIOR EXTERIOR ENTRY/ EXIT VESTIBULE 100 SECURITY OFFICE 101 SALES AREA 102 EXISTING ELEC. RM 103 I.T. CLOSET 101A STAIR ST1 POS STATIONS 102A HALL 103A ACCESSIBLE RESTROOM 106 FLUSH MOUNT CRAWLSPACE ACCESS PANEL (PROVIDE EMERGENCY LIGHTING AND FIRE ALARM NOTIFICATION IN CRAWLSPACE AS REQUIRED) FE FE UP SD SD SD F F F F MAX TRAVEL DISTANCE = ± 47'-6" (75' ALLOWED) MAX TRAVEL DISTANCE = ± 72'-10" (75' ALLOWED) HALL 104 F SLOPE 5% MAX.DN W W W JAN. CL. 105 SCALE: 2 SECOND FLOOR EGRESS PLAN 1/4" = 1'-0" N DESIGN NORTH EXTERIOR EXTERIOR EXTERIOR EXTERIOR STAIR ST1 STO. CL. 201 CORRIDOR 200 BREAK ROOM 204 COUNTING RM 206VAULT 207 OFFICE 203 PACKAGING 202 FE DN SD SD F F F BATH 205 ATTIC ACCESS (PROVIDE EMERGENCY LIGHTING AND FIRE ALARM NOTIFICATION IN ATTIC AS REQUIRED) MAX TRAVEL DISTANCE = ± 72'-10" (75' ALLOWED) JAN. CL. 200A W CLASS A,B,C, 20-B FIRE EXTINGUISHER - SEE NOTE #2 BELOW MINIMUM 44" CLEAR EGRESS PATH LED EXIT SIGN - REFER TO NOTE #3 BELOW FIRE ALARM PULL STATION FIRE ALARM AUDIO VISUAL DEVICE NOTE: 1.E = EXISTING, ER = EXISTING TO BE RELOCATED, N = NEW, W = WALL-MOUNTED 2.G.C. SHALL PROVIDE FIRE EXTINGUISHERS AND SIGNAGE AS REQUIRED BY LOCAL CODE AND AS PER THE FIRE DEPARTMENT REQUEST. 3.ILLUMINATED EXIT SIGN WITH DESIGNATION OF 'EL' INDICATES LITE TO BE EDGE LIT. FE SD CEILING MOUNTED SMOKE DETECTOR FAA FIRE ALARM ANNUNCIATOR PANEL INDICATES PORTION OF EXISTING CONSTRUCTION NOT IN CONTRACT FCAP FIRE ALARM CONTROL PANEL F F BATTERY BACK-UP EMERGENCY LIGHTING JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_GC-201 EGRESS FLOOR PLANS.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID GC 201 EGRESS FLOOR PLANS UP ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) UP UP SCALE: 1 FIRST FLOOR DEMOLITION PLAN 1/4" = 1'-0" EXISTING ANGELO'S BARBER SHOP 1 1 2 2 1A 1A 1 3 2 2 2 2 3 2 2 2 4 EXIST. BATH EXISTING BATH EXIST. STAIR EXIST. HALL EXISTING HALL EXISTING HEMPEST SHOP EXISTING HEMPEST SHOP STORAGE EXIST. CLO. EXISTING CLOSET EXIST. STOR. CLO. 1 1 5 5 1 7 8 8 8 7 7 8 10 BELOW 10 BELOW 2 EXISTING STORAGE SHED 11 11 11 12 13 14 (N.I.C.) 3 3 15 17 17± 22'-2"APPROXIMATE EXTENT OF VINYL SIDING REMOVAL16 ± 24'-6"APPROXIMATE EXTENT OF VINYL SIDING REMOVAL16 16 16 10A10A 1A 19 N DESIGN NORTH (ENTIRE TENANT SPACE, TYP.) 15 (ENTIRE TENANT SPACE, TYP.) 15 (ENTIRE TENANT SPACE, TYP.) 1 1 1 9 16A EXTENT OF 4x4 LANDSCAPING TIMBERS DEMOLITION EXTENT OF 4x4 LANDSCAPING TIMBERS DEMOLITION EXISTING ELECTRICAL EQUIPMENT AND METERS TO REMAIN EXISTING ELEC. ROOM 6 6 TYP. TYP. 9 3 1 20 ± 1'-9" G.C. TO V.I.F. 18 SCALE: 2 SECOND FLOOR DEMOLITION PLAN 1/4" = 1'-0" DN EXIST. BATH EXIST. CLO. EXIST. STAIR EXISTING BEDROOM EXISTING BEDROOM EXISTING CLOSET EXIST. HALL EXISTING LIVING ROOM EXISTING KITCHEN EXISTING DINING 1 2 2 2 2 2 2 4 11 1 5 5 1 6 1 1 8 7A TYP. 7A TYP. 7A TYP. 7A EXISTING DECK 2 EXISTING APARTMENT 15 (ENTIRE APT., TYP.) 17 1717± 24'-6"APPROXIMATE EXTENT OF VINYL SIDING REMOVAL± 25'-5"APPROXIMATE EXTENT OF VINYL SIDING REMOVAL16 16 3 18 18 EXTENT OF DEMO TO BE COORDINATED WITH NEW VAULT ROOM LOCATION. G.C. TO COORDINATE WORK WITH NEW SECURED FLOORING. REFER TO FRAMING AND FLOOR PLANS FOR ADDITIONAL INFORMATION N DESIGN NORTH 16A ± 11'-0"G.C. TO V.I.F.± 10'-0" G.C. TO V.I.F. 18 18 DEMOLITION LEGEND EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN EXISTING DOOR & FRAME ASSEMBLY TO REMAIN EXISTING DOOR & FRAME ASSEMBLY TO BE DEMOLISHED DESIGNATES AREA OF BUILDING N.I.C. - NO WORK TO BE DONE (ADJACENT TENANT SPACE) #DESIGNATES DEMOLITION KEY PLAN NOTE DEMOLISH EXISTING PARTITION TO EXTENTS SHOWN AND ALL ASSOCIATED FRAMING, MECHANICAL EQUIPMENT, ELECTRICAL WIRING, ETC. IN THEIR ENTIRETY. WHERE REMOVAL OF EXISTING PARTITION INTERSECTS PARTITIONS THAT ARE TO REMAIN. PATCH, REPAIR AND BLEND WITH ADJACENT SURFACES TO MATCH EXISTING. DEMOLISH EXISTING BUILD-OUT PARTITION BACK TO EXTERIOR WALL TO EXTENTS SHOWN AND ALL ASSOCIATED ITEMS REFERENCED ON DEMO "NOTE #1". DEMOLISH EXISTING DOOR & FRAME IN THEIR ENTIRETY, ADJACENT PARTITION TO REMAIN, U.N.O. DEMOLISH EXISTING EXTERIOR WINDOW GLAZING AND FRAME SYSTEM, INCLUDING BUT NOT LIMITED TO ALL ASSOCIATED MILLWORK IN ITS ENTIRETY. DEMOLISH EXISTING INTERIOR WOOD STAIR AND ALL ASSOCIATED MATERIALS IN THEIR ENTIRETY, INCLUDING BUT NO LIMITED TO HANDRAILS, ETC. DEMOLISH EXISTING PLUMBING FIXTURES IN THEIR ENTIRETY. CUT AND CAP AND/OR REMOVE IN ITS ENTIRETY, EXISTING PIPING NOT BEING USED AND/OR CONFLICTING WITH NEW WORK, BACK TO WALL AND/OR FLOOR AS TO ALLOW FOR THE INSTALLATION OF NEW FINISHES. DEMOLISH EXISTING MILLWORK CABINETRY, COUNTERS, SHELVING, ETC., INCLUDING ALL ASSOCIATED MATERIALS AND SUPPORTING BRACKETS. DEMOLISH EXISTING FLOORING AND WALL BASE IN ITS ENTIRETY. PREP CONCRETE SLAB TO RECEIVE NEW FLOOR FRAMING. DEMOLISH EXISTING FLOORING AND WALL BASE IN ITS ENTIRETY DOWN TO EXISTING SUBFLOOR. PREP EXISTING SUBFLOOR AS REQUIRED TO RECEIVE NEW FLOOR FINISH. DEMOLISH EXISTING FLOORING & SUBFLOORING IN ITS ENTIRETY DOWN TO EXISTING WOOD FLOOR FRAMING BELOW. G.C. TO VISUALLY INSPECT EXISTING FLOOR FRAMING AND REPLACE MEMBERS AS REQUIRED DUE TO ANY EXISTING ROT DAMAGE AND/OR CONFLICTING WITH NEW FLOOR FRAMING WORK. DEMOLISH EXISTING WOOD FLOOR ASSEMBLY IN ITS ENTIRETY, INCLUDING FLOOR FRAMING AND ASSOCIATED MATERIALS. G.C. TO PROVIDE TEMPORARY SHORING TO EXISTING EXTERIOR AND INTERIOR BEARING WALLS AS NEEDED PRIOR TO DEMOLITION AND PROVIDE NEW FRAMING AS REQUIRED TO ACCOMMODATE FOR NEW LOWER FLOOR FRAMING ELEVATION. G.C. TO COORDINATE DEMOLITION WORK WITH NEW PROPOSED FLOOR FRAMING WORK AND INFORM THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. DEMOLISH TOP OF EXISTING CMU FOUNDATION WALL AS REQUIRED TO ACCOMMODATE FOR NEW LOWER WOOD FLOOR FRAMING JOISTS. G.C. TO PROVIDE TEMPORARY SHORING OF EXISTING EXTERIOR AND INTERIOR BEARING WALLS AS NEEDED PRIOR TO DEMOLITION. G.C. TO COORDINATE DEMOLITION WORK WITH NEW PROPOSED FRAMING WORK. G.C. TO INFORM THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. DEMOLISH TOP OF EXISTING CMU FOUNDATION WALL AS REQUIRED TO ACCOMMODATE THE INSTALLATION OF NEW INTERIOR STAIR AND EXTERIOR DOORS. G.C. TO COORDINATE DEMOLITION WORK WITH NEW INTERIOR STAIR AND EXTERIOR DOORS LOCATIONS. REFERENCE FLOOR PLAN FOR ADDITIONAL INFORMATION. REMOVE EXISTING THRU-WALL A/C UNIT AND ALL ASSOCIATED SUPPORTS AND/OR BRACKETS IN THEIR ENTIRETY. G.C. TO INFILL OPENING TO MATCH ADJACENT WALL CONSTRUCTION. WALL INFILL TO MEET 2015 IECC CODE REQUIREMENTS, REFER TO FLOOR PLAN FOR ADDITIONAL INFORMATION. MATCH AND BLEND FINISHES WITH ADJACENT SURFACES. DEMOLISH EXISTING CONCRETE STEPS AND WALKWAY BACK TO STREET SIDEWALK IN ITS ENTIRETY. G.C. TO PROVIDE NEW LANDSCAPING IN DEMOLITION AREAS TO MATCH ADJACENT. COORDINATE DEMOLITION AND NEW LANDSCAPING WORK WITH OWNER. DEMOLISH EXISTING WOOD DECK PLATFORM, STAIRS, RAILINGS AND ALL ASSOCIATED COMPONENTS, INCLUDING BUT NOT LIMITED TO CONCRETE FOUNDATION PIERS IF EXISTING, CONCRETE WALKWAY AND LEDGER BOARD WITH ASSOCIATED ANCHORS. COORDINATE DEMOLITION WORK WITH NEW WORK AND WITH OWNER. DEMOLISH EXISTING CONCRETE WALKWAY, 4X4 LANDSCAPING TIMBERS & ASSOCIATED LANDSCAPING BACK TO ASPHALT DRIVEWAY AS TO ALLOW FOR NEW CONCRETE ACCESSIBLE ENTRANCE WALKWAY. COORDINATE DEMOLITION WORK WITH NEW WORK AND WITH OWNER. PROVIDE NEW LANDSCAPING IN ALL EXTERIOR AREAS AFFECTED BY DEMOLITION AND/OR NEW WORK. COORDINATE NEW LANDSCAPING WITH OWNER. DEMOLISH EXISTING ELECTRICAL BASEBOARD AND ALL ASSOCIATED COMPONENTS, BUT NOT LIMITED TO THERMOSTATS, LOW VOLTAGE WIRING, JUNCTION BOXES, ETC.. DEMOLISH EXISTING VINYL SIDING, SHUTTERS & VENTED SOFFIT DOWN TO SUBSTRATE AS NOTED. G.C. TO VISUALLY INSPECT WOOD SUBSTRATE & REPLACE DAMAGED AND/OR ROTTED AREAS AS REQUIRED (ALLOW FOR 20% REPLACEMENT IN BASE BID). EXISTING RAKE & SOFFIT BOARDS TO REMAIN. G.C. TO VISUALLY INSPECT BOARDS AND REPLACE AS REQUIRED. REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFO.. DEMOLISH EXISTING GUTTER AND DOWNSPOUT AND ALL ASSOCIATED COMPONENTS, INCLUDING BUT NOT LIMITED TO SUPPORTING BRACKETS, FASTENERS, ETC. PREP SURFACES TO RECEIVE NEW GUTTER & DOWNSPOUT. REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. DEMOLISH EXISTING BUILDING EXTERIOR SIGNAGE AND ALL ASSOCIATED COMPONENTS, INCLUDING BUT NOT LIMITED TO SUPPORTING BRACKETS, FASTENERS AND IF APPLICABLE, LIGHTING COMPONENTS BACK TO POWER SOURCE. WHERE APPLICABLE, PATCH AND/OR REPAIR ROOF AS REQUIRED TO MATCH EXISTING DUE TO SIGNAGE REMOVAL. DEMOLISH EXISTING GYPSUM WALL BOARD AND REMOVE EXTERIOR WALL INSULATION. REFER TO FLOOR AND FRAMING PLANS FOR ADDITIONAL INFORMATION. EXISTING ELECTRICAL SUB-PANEL TO BE DEMOLISHED AND/OR RELOCATED TO SECOND FLOOR STAIR CLOSET. G.C. TO COORDINATE WORK AND ENGINEERING DESIGN WITH D/B ELECTRICAL SUBCONTRACTOR. EXISTING TENANT MAILBOXES IN THIS AREA TO REMAIN. G.C. TO PROTECT AND MAINTAIN ACCESSIBLE TO BUILDING TENANTS THROUGHOUT CONSTRUCTION. DEMOLITION PLAN KEY NOTES -# 1A 3 4 5 6 1 2 11 12 7 7A 8 13 14 15 9 16 17 18 10 19 16A 10A 20 1.G.C. TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND INFORM THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. 2.G.C. IS RESPONSIBLE TO PROVIDE TEMPORARY SUPPORT/SHORING OF EXISTING CONSTRUCTION PRIOR TO DEMOLITION AS REQUIRED TO ACCOMMODATE DEMOLITION AND CONSTRUCTION ACTIVITIES. 3.DEMOLITION CONTRACTOR TO PATCH, REPAIR, AND/OR REPLACE ALL ITEMS AND MATERIAL DESIGNATED TO REMAIN OR BE RELOCATED THAT ARE DAMAGED DUE TO DEMOLITION ACTIVITIES. 4.G.C. TO PATCH AND REPAIR EXISTING-TO-REMAIN WALLS TO MATCH EXISTING ADJACENT CONSTRUCTION. 5.DEMOLITION CONTRACTOR TO VISIT SITE PRIOR TO SUBMITTING BID. NO ADDITIONAL COMPENSATION WILL BE PAID BY THE TENANT FOR WORK RESULTING FROM A LACK OF FAMILIARITY WITH THE EXISTING CONDITIONS. GENERAL DEMOLITION NOTES: 1.G.C. TO INCLUDE AN ALLOWANCE TO DEMOLISH ENTIRE SECOND FLOOR FRAMING FLOOR JOISTS IN THEIR ENTIRETY AND PREPARE WALLS TO RECEIVE NEW FLOORING JOISTS DUE TO POSSIBLE UNKNOWN STRUCTURAL FLOOR CONSTRUCTION DEFICIENCIES. DEMOLITION ALLOWANCES: (REFER TO SHEET G101 FOR ADDITIONAL DEMOLITION SPECIFICATIONS) JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_AD-100 DEMOLITION FLOOR PLANS & NOTES.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID AD 100 DEMOLITION FLOOR PLANS & NOTES SCALE: 2 REFLECTED CEILING PLAN 1/4" = 1'-0" SECOND FLOOR DEMOLITION EXIST. BATH EXIST. CLO. EXIST. STAIR EXISTING BEDROOM EXISTING BEDROOM EXISTING CLOSET EXIST. HALL EXISTING LIVING ROOM EXIST. KITCHEN AREA EXIST. DINING AREA 2 3 2 3 2 3 2 3 2 3 2 43 EXISTING APARTMENT 2 53 (ENTIRE APT., TYP.) N DESIGN NORTH SCALE: 1 REFLECTED CEILING PLAN 1/4" = 1'-0" FIRST FLOOR DEMOLITION 1 6 6 EXISTING ANGELO'S BARBER SHOP EXIST. BATH EXISTING BATH EXIST. STAIR EXIST. HALL EXIST. HALL EXISTING ELEC. ROOM EXISTING HEMPEST SHOP EXISTING HEMPEST SHOP STORAGE EXIST. CLO. EXISTING CLOSET EXIST. STOR. CLO. EXISTING STORAGE SHED (N.I.C.) 2 TYP. 2 TYP. 5 3 2 TYP. 3 2 TYP. 43 2 TYP. 4 3 2 3 2 TYP. 3 (OPEN TO STRUCT. ABOVE) 2 3 3 2 TYP. 53 2 TYP. 53 2 3ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) N DESIGN NORTH SALVAGE, STORE AND PROTECT EXISTING TIN CEILING PANELS FOR RE-USE IN NEW TENANT SPACE. ARCHITECT TO INSPECT AND SELECT PANELS FROM SALVAGED MATERIAL FOR RE-USE. DEMOLISH ALL EXISTING WALL AND CEILING MOUNTED LIGHT FIXTURES, MOUNTING BRACKETS, JUNCTION BOXES, ABANDONED WIRING, ETC., INCLUDING WIRING BACK TO ELECTRICAL PANEL. TYP. THROUGHOUT ENTIRE PROPOSED TENANT SPACE WORK AREA. DEMOLISH ALL EXISTING CEILINGS IN THEIR ENTIRETY, TO INCLUDE ALL GYPSUM CEILINGS, SOFFITS, DROP CEILINGS WITH ALL ASSOCIATED SUPPORT SYSTEMS. DEMOLISH EXISTING BATHROOM EXHAUST FANS, DUCTWORK BACK TO ROOF AND ALL ASSOCIATED MATERIALS IN THEIR ENTIRETY. DEMOLISH ALL EXISTING HVAC DUCTWORK, PIPPING, ELECTRICAL WIRING BACK TO EXISTING PANEL AND EQUIPMENT WITHIN WORK AREA NOT BEING RE-USED AND/OR CONFLICTING WITH NEW WORK. CAP AND PATCH EXISTING SYSTEMS FROM ADJACENT BUILDINGS AS IT MAY OCCUR. DEMOLISH EXISTING EXTERIOR LIGHT FIXTURES AT ROOF SOFFIT AND PREP AREA TO RECEIVE NEW EXTERIOR LIGHT FIXTURE. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION. DE-ENERGIZE POWER TO FIXTURE LOCATIONS DURING CONSTRUCTION AS REQUIRED. ALL EXTERIOR BUILDING LIGHTING TO BE CONNECTED TO OWNER'S ELECTRICAL SERVICE METER. DEMOLITION RCP KEY NOTES -DEMOLITION LEGEND EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN DESIGNATES AREA OF BUILDING N.I.C. - NO WORK TO BE DONE (ADJACENT TENANT SPACE) # 2 1 #DESIGNATES DEMOLITION KEY REFLECTED CEILING PLAN NOTE 3 4 5 6 JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_AD-200 DEMOLITION REFLECTED CEILING PLANS.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID AD 200 DEMOLITION REFLECTED CEILING PLANS JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-001 STRUCTURAL GENERAL NOTES.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 001 STRUCTURAL GENERAL NOTES JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-002 GENERAL STRUCTURAL DETAILS.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 002 GENERAL STRUCTURAL DETAILS ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) SCALE: 1 FOUNDATION PLAN 1/4" = 1'-0" 3-1/2" DIA. CONCRETE FILLED LALLY COLUMN W/ BASEPLATE AND SIMPSON LCC CAP ON 30" x 30" x 12" DEEP REINF. CONC. FOOTING W/ (3) #5 E.W.± 8'-3"± 8'-3"1'-0"1'-0"± 7'-3"± 7'-3"1'-0"1'-0" BUILT-UP GIRDER - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. 3-1/2" DIA. CONCRETE FILLED LALLY COLUMN W/ BASEPLATE AND SIMPSON LCC CAP ON 30" x 24" x 12" DEEP REINF. CONC. FOOTING W/ (3) #5 E.W., TYP. AT ALL OUTER MIDDLE FOOTINGS 3-1/2" DIA. CONCRETE FILLED LALLY COLUMN W/ BASEPLATE AND SIMPSON LCC CAP ON 24" x 24" x 12" DEEP REINF. CONC. FOOTING W/ (3) #5 E.W., TYP. AT ALL CORNER FOOTINGS 12" LONG #4 DOWELS AT 12" O.C. W/ 4" EMBEDMENT IN EXISTING CONCRETE FOOTING. DRILL HOLES IN EXISTING FOOTING TO ACCEPT DOWELS AND FILL WITH EPOXY TYP. AT ALL SIDES ABUTTING EXISTING FOOTINGS 2 A100 1 A400 3" CONC. RAT SLAB ON 6 MIL VAPOR BARRIER ON 6" CRUSHED STONE. 2 A400 N DESIGN NORTH SCALE: 2 DETAIL @ INT. FOOTING 1" = 1'-0" 1'-3" 2'-6" 1'-3"3"1'-0"1'-3"(3) - #5 REBAR EACH WAY - TYPICAL 3-1/2" DIAMETER LALLY COLUMN W/ BASEPLATE ANCHORED TO FOOTING 3" CONC. SLAB ON 6 MIL VAPOR BARRIER OVER 6" CRUSHED STONE 2'-6" x 2'-6" CONCRETE FOOTING BELOW SLAB 1/4" LEVELING PLATE AND 3/4" NON-SHRINK GROUT 9"3/4" BASE PLATE x 12" SQ. W/ (4) 1" DIA. A307 ANCHOR BOLTS W/ 4" STANDARD HOOK 1 - THE ALLOWABLE PRESUMED SOIL BEARING CAPACITY IS 2,000 PSF, WHICH IS TO BE VERIFIED IN THE FIELD BEFORE CONSTRUCTION. 2 - FOOTING SHALL BE CARRIED TO LOWER ELEVATION THAN SHOWN ON THE DRAWINGS IF REQUIRED TO REACH PROPER BEARING CAPACITY. 3 - COMPACT ALL FILL UNDER FOOTINGS AND SLABS TO 95% MAX DRY DENSITY AND VERIFY. FOOTINGS & CONCRETE NOTES: FOOTINGS:CONCRETE: 1 - ALL CONCRETE WORK AND MATERIALS SHALL COMPLY WITH THE SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-96). 2 - FOOTING - CONCRETE SHALL HAVE A 28-DAY COMPRESSIVE STRENGTH OF 3000 PSI, WITH MAXIMUM 3/4 INCH AGGREGATE AND MAXIMUM 6% AIR ENTRAINMENT FOR EXTERIOR CONCRETE EXPOSED TO MOISTURE. 3 - CRAWLSPACE SLAB - CONCRETE SHALL HAVE A 28-DAY COMPRESSIVE STRENGTH OF 3000 PSI, WITH MAXIMUM 3/4 INCH AGGREGATE 4 - EXTERIOR CONCRETE WALKS/RAMP - CONCRETE SHALL HAVE A 28-DAY COMPRESSIVE STRENGTH OF 4000 PSI, WITH MAXIMUM 3/4 INCH AGGREGATE AND MAXIMUM 6% AIR ENTRAINMENT FOR EXTERIOR CONCRETE EXPOSED TO MOISTURE. 5 - ALL REINFORCING STEEL SHALL BE DEFORMED BARS OF NEW BILLET STEEL CONFORMING TO ASTM A 615 GRADE 60. ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185. 6 - CONCRETE COVER OF REINFORCING BARS SHALL BE AS FOLLOWS: A. 3" AT CONCRETE PLACED DIRECTLY AGAINST EARTH. B. 2" AT WALLS RETAINING SOIL OR WATER. C. 1-1/2" AT ALL OTHER LOCATIONS. 7 - NO HORIZONTAL CONSTRUCTION JOINTS ARE ALLOWED, UNLESS SPECIFICALLY SHOWN ON THE DRAWINGS OR ALLOWED IN WRITING BY THE ENGINEER. 8 - ALL GROUT FOR BASE PLATES SHALL BE NON-SHRINK AND NON-METALLIC, WITH A MINIMUM COMPRESSIVE STRENGTH OF 5000 PSI. 9 - PROVIDE 1/2" ISOLATION JOINTS AROUND SLAB PERIMETER AND ALL SLAB PENETRATIONS. 10 - SAWCUTS TO BE 1/4 DEPTH OF OVERALL SLAB THICKNESS. PROVIDE 2'-0 X 2'-0" DIAMOND SHAPED SAW CUT AT COLUMN AND SAWCUT AT COLUMN LINE, MID-SPAN, AND INSIDE CORNERS. SAW CUT AT SLAB TO BE 8'-0" MAX SPACING. JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-100 FOUNDATION PLAN, NOTES, & DETAILS.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 100 FOUNDATION PLAN, NOTES, & DETAILS SCALE: 1 FIRST FLOOR FAMING PLAN 1/4" = 1'-0" ± 5'-0" G.C. TO V.I.F. SOLID WOOD BLOCKING, TYP. ± 19'-7" G.C. TO V.I.F. ± 17'-9" G.C. TO V.I.F. 8"8" ± 42'-4" G.C. TO V.I.F.± 13'-7"G.C. TO V.I.F.± 19'-1"G.C. TO V.I.F.8"8"± 26'-0"G.C. TO V.I.F.± 45'-9"G.C. TO V.I.F.EXISTING 8" CMU FOUNDATION WALL TO REMAIN. REPAIR WALL AS REQUIRED AND GROUT SOLID, TYP. OF (4) EXISTING 2x4 EXTERIOR WOOD FRAME WALL ABOVE TO REMAIN, TYP. FACE OF FOUNDATION WALL BELOW, TYP. EXISTING WOOD FLOOR FRAMING TO REMAIN. G.C. TO VISUALLY INSPECT FLOOR JOISTS AND REPLACE MEMBERS AS REQUIRED DUE TO ANY EXISTING ROT DAMAGE AND/OR CONFLICTING W/ NEW FLOOR FRAMING WORK. EXISTING WOOD BLOCKING TO REMAIN. IF NONE EXISTS, G.C. TO INSTALL WOOD BLOCKING AS REQUIRED 2x WOOD FLOOR JOISTS @ 16" O.C. TO MATCH EXISTING. G.C. TO INSTALL NEW WOOD FLOOR JOISTS AT SAME ELEVATION OF ANGELO'S BARBER SHOP EXISTING FLOOR JOISTS. PROVIDE WOOD JOIST LEDGERS AS REQUIRED TO PROPERLY SUPPORT AND SECURE NEW FLOOR JOISTS. G.C. TO FIELD VERIFY EXISTING CONDITIONS AND REVIEW W/ ARCHITECT SOLID WOOD BLOCKING, TYP.2 x 10 WOOD JOISTS @ 16" O.C.EXISTING 8" CMU FOUNDATION WALLS TO REMAIN. REPAIR WALL AS REQUIRED AND GROUT SOLID, TYP. OF (4) EXISTING CMU FOUNDATION WALL BELOW SOLID WOOD BLOCKING, TYP. 2X WOOD RIM JOIST 2X WOOD RIM JOIST SOLID WOOD BLOCKING, TYP. EXISTING 2x4 EXTERIOR WOOD FRAME WALL TO REMAIN, TYP. 2 x P.T. WOOD JOISTS @ 16" O.C. 2 x P.T. WOOD JOISTS @ 16" O.C. EXISTING 2x4 WOOD FRAME WALL TO REMAIN, TYP. EXISTING CONCRETE SLAB TO REMAIN, TYP. 2 x P.T. WOOD FLOOR JOISTS @ 16" O.C. OVER EXISTING CONCRETE SLAB. G.C. TO INSTALL NEW WOOD FLOOR JOISTS TO MATCH NEW FLOOR ELEVATION THROUGHOUT. ± 17'-6" G.C. TO V.I.F. 1 A400 2 A400 (2) 1-3/4" x 9-1/4" LVL CONT. (2) SPANS W/ SIMPSON LCC 3.5-3.5 LALLY COLUMN CAP, TYP. (3) 1-3/4" x 9-1/4" LVL CONT. (2) SPANS W/ SIMPSON LCC 5.25-3.5 LALLY COLUMN CAP (2) 1-3/4" x 9-1/4" LVL CONT. (2) SPANS W/ SIMPSON LCC 3.5-3.5 LALLY COLUMN CAP, TYP. ATTACH 2X10 RIM BOARD TO EXISTING CMU WALL W/ 2-1/2" DIA. HILTI KWIK BOLTS @ 32" O.C. W/ MIN. 4" EMBEDMENT, TYP. NOTE: G.C. TO SHORE UP EXISTING STRUCTURE AND FOUNDATION WALLS AS REQUIRED FOR ALL DEMOLITION AND NEW WORK, TYP.± 3'-0" R.O.G.C. TOVERIFYW/ MANUF.2X10 FLOOR ACCESS DOOR FRAMED OPENING. G.C. TO FIELD VERIFY LOCATION & COORDINATE ROUGH OPENING W/ DOOR MANUFACTURER ± 13'-9" R.O.G.C. TO COORD. FINAL LOCATION W/ FLOOR PLAN± 3'-0" R.O. ± 6" INSTALL (2) 1-3/4" x 9-1/4" LVL BELOW BEARING WALL ABOVE 2 x 10 WOOD FLOOR JOISTS @ 16" O.C. G.C. TO INSTALL NEW WOOD FLOOR JOISTS AT SAME ELEVATION OF ANGELO'S BARBER SHOP EXISTING FLOOR JOISTS. PROVIDE WOOD RIM JOISTS AS REQUIRED. N DESIGN NORTH 1- FRAME INTERIOR STAIR WITH (3) 2x12 STRINGERS. FRAME STAIR LANDINGS WITH 2x8 JOISTS AT 16" O.C, DOUBLE OUTSIDE STRINGERS AND LANDING JOISTS. TOP OF STRINGERS TO BE JOIST HUNG FROM 2x12 HEADER. 2- INSTALL ADDITIONAL FLOOR JOISTS BENEATH INTERIOR PARTITIONS RUNNING PARALLEL TO FRAMING. ALTERNATE TO BE BLOCKING AT 24" O.C. RUNNING PERPENDICULAR TO FLOOR JOISTS WITHIN JOIST BAY BENEATH INTERIOR WALL PARTITIONS. 3- DEFLECTION AT FLOOR DESIGNED FOR L/480. 4- INSTALL METAL JOIST HANGERS AT ALL PERPENDICULAR CONNECTIONS. G.C. TO MATCH CAPACITY OF HANGER WITH INTENDED USE. 5- INSTALL SOLID BLOCKING BETWEEN JOISTS AT LOCATIONS ABOVE SUPPORT BEAMS. 6- P.T. LUMBER MUST BE USED WHERE WOOD COMES IN CONTACT WITH CONCRETE. 7- FLOOR FRAMING TO BE ADJUSTED AS REQUIRED TO ACCOMMODATE PLUMBING FIXTURE LOCATIONS ABOVE. WOOD FRAMING NOTES: SCALE: 2 SECOND FLOOR FRAMING PLAN 1/4" = 1'-0" ± 19'-7" G.C. TO V.I.F. ± 42'-4" G.C. TO V.I.F. ± 5'-0" G.C. TO V.I.F. ± 17'-9" G.C. TO V.I.F.± 25'-3"G.C. TO V.I.F.10'-3" SISTER 1ST & 2ND FLOOR WALL STUDS 2'-8" EXISTING WOOD BLOCKING TO REMAIN. IF NONE EXISTS, G.C. TO INSTALL WOOD BLOCKING AS REQUIRED EXISTING WOOD FLOOR FRAMING TO REMAIN. (REFER TO FRAMING ALLOWANCE #1 FOR ADDITIONAL INFORMATION) 2x4 WALL FRAMING BELOW TO SUPPORT STAIR OPENING SECOND FLOOR FRAMING SOLID WOOD BLOCKING, TYP. 2x12 WOOD RIM JOIST(2) 1-3/4" x 11-1/4" LVL BEAMS EXISTING WOOD FLOOR JOISTS TO REMAIN. G.C. TO CUT BACK JOISTS FOR NEW FRAMED STAIR OPENING AS REQUIRED, TYP. EXISTING WOOD FLOOR FRAMING TO REMAIN. (REFER TO FRAMING ALLOWANCE #1 FOR ADDITIONAL INFORMATION) EXISTING WOOD BLOCKING TO REMAIN. IF NONE EXISTS, G.C. TO INSTALL WOOD BLOCKING AS REQUIRED INFILL EXISTING FLOOR STAIR OPENING W/ 2X10 WOOD JOISTS @ 16" O.C. AS REQUIRED. ± 8'-0" G.C. TO V.I.F.CL CL 3 1/2" x 3 1/2" PSL POST TO FLOOR BELOW. G.C. TO PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS TO TOP OF FOUNDATION WALL. POST CAP TO BE "SIMPSON" "LCE4", ON BOTH SIDES OF BEAM TO POST CONNECTION - TYP. OF (2)± 15'-3 1/2" G.C. TO V.I.F. (2) 1 3/4" X 11 1/4" LVL BEAMS BELOW CEILING JOISTS. 5 1/2" x 5 1/2" PSL POST WITH SIMPSON LCE4 POST CAP, BOTH SIDES OF BEAM TO POST CONNECTION - TYP. OF (2) (3) 1 3/4" X 14" LVL BEAM BELOW CEILING JOISTS. ± 22'-7" G.C. TO V.I.F. CL 2 3/4" CL 5 1/2" x 5 1/2" PSL POST TO FLOOR BELOW. G.C. TO PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS TO TOP OF FOUNDATION WALL. 1 A400 2 A400 (2) 1-3/4" x 11-1/4" LVL BEAMS (2) 2x12 FLUSH FRAMED HEADER 7'-0" 4'-5" 5'-11"4'-5"4'-3 1/2"12'-4"SISTER 1ST & 2ND FLOOR WALL STUDS3 1/2"3'-11 1/2"4'-1"EXISTING/NEW 2x4 EXTERIOR WOOD STUD WALL. G.C. TO SISTER NEW & EXISTING WALL STUDS @ FIRST & SECOND FLOOR LEVELS WITH 2X4 FULL HEIGHT STUDS. PROVIDE 2X4 SISTER STUDS AT STAIR EXTERIOR WALLS ONLY. 2x4 @ 16" O.C. PARTITION BELOW, TYPICAL. (3) 2x4 WOOD POST BELOW. G.C. TO PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS TO TOP OF FOUNDATION WALL (4) 2x4 WOOD POST BELOW. G.C. TO PROVIDE SOLID BLOCKING BETWEEN FLOOR JOISTS TO TOP OF FOUNDATION WALL (2) 2x12 FLUSH FRAMED HEADER G.C. TO INSTALL AN ADDITIONAL WOOD FLOOR JOIST TO MATCH EXISTING, CENTERED IN EACH EXISTING JOIST BAY BELOW ENTIRE NEW VAULT ROOM. PROVIDE CONTINUOUS SOUND ATTENUATION BATTS BETWEEN FLOOR JOISTS AND PROVIDE AMICO SECURITY MESH, ASM .75-9F MIN. ABOVE FLOOR JOISTS WITHIN ENTIRE VAULT ROOM FLOOR WITH SECURA CLIPS 12" O.C., FOLLOWED BY NEW T&G PLYWOOD SUB-FLOOR AND SCHEDULED FLOORING. SOLID WOOD BLOCKING, TYP. EXISTING WOOD FLOOR JOIST FRAMING TO REMAIN. (REFER TO FRAMING ALLOWANCE #2 FOR ADDITIONAL INFORMATION) N DESIGN NORTH 1.G.C. TO INCLUDE AN ALLOWANCE TO REPLACE ENTIRE SECOND FLOOR FRAMING WITH 2X10 WOOD JOISTS @ 16" O.C. DUE TO POSSIBLE UNKNOWN STRUCTURAL FLOOR CONSTRUCTION DEFICIENCIES. 2.G.C. TO INCLUDE ALLOWANCE TO PROVIDE NEW FLUSH FRAMED LVL HEADERS, (3) 1-3/4" x 14" (ESTIMATED DUE TO CONCEALED FRAMING) WITH (1) INTERMEDIATE 5 1/2" x 5 1/2" PSL POST & FOOTING TO SUPPORT SECOND FLOOR FRAMING SUSPECTED OF CURRENTLY BEARING ON INTERIOR WALLS SCHEDULED TO BE DEMOLISHED. STRUCTURAL ENGINEER TO REVIEW CURRENT FLOOR FRAMING AND PROVIDE FINAL DIRECTION UPON EXPOSURE OF EXISTING FRAMING DURING DEMOLITION. FRAMING ALLOWANCES: JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-101 FRAMING PLANS, NOTES, & DETAILS.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 101 FRAMING PLANS, NOTES, & DETAILS FLOOR PLAN LEGEND EXISTING WALL TO REMAIN NEW WALL NEW DOOR WALL TYPE, REFER TO PARTITION TYPES DOOR TAG, REFER TO DOOR SCHEDULE WINDOW TAG, REFER TO WINDOW SCHEDULE ROOM TAG, REFER TO FINISH SCHEDULE INDICATES OTHER TENANT AREA N.I.C. # CONSTRUCTION KEY NOTES RM# DR# A G.C. TO INFILL EXISTING EXTERIOR WALL OPENING TO MATCH ADJACENT WALL CONSTRUCTION. PROVIDE 2LB. CLOSED-CELL SPRAY FOAM INSULATION IN WALL CAVITY AND ENSURE WALL INFILL MEETS 2015 IECC CODE REQUIREMENTS. CREATE SEAMLESS TRANSITION BETWEEN NEW AND EXISTING AND PREP SURFACE FOR NEW FINISHES. G.C . TO INFILL EXISTING INTERIOR WALL OPENING TO MATCH ADJACENT WALL CONSTRUCTION. PROVIDE SOUND ATTENUATION BATT INSULATION AT TENANT DEMISING WALL INFILLS. CREATE SEAMLESS TRANSITION BETWEEN NEW AND EXISTING AND PREP SURFACE FOR NEW FINISHES. ALIGN FACE OF NEW PARTITION WITH FACE OF EXISTING WALL. CREATE SEAMLESS TRANSITION BETWEEN NEW AND EXISTING AND PREP SURFACE FOR NEW FINISHES. EXTERIOR LANDINGS AND WALKWAYS TO BE REINFORCED CONCRETE WITH BROOM FINISH ON 18" CRUSHED STONE. FINISHED SURFACE TO SLOPE UP TO CREATE A FLUSH TRANSITION BETWEEN INTERIOR AND EXTERIOR AT FRONT ENTRANCES. LANDINGS AND WALKWAYS ADJACENT TO BUILDING TO BE DOWELED TO FOUNDATION WALL WITH #4 BAR X 2'-0" LONG WITH 4" MIN. EMBEDMENT. INSTALL DOWELS 2'-0" O.C. WITH MIN. OF (3) PER DOOR LOCATION. ALL LANDINGS AND WALKWAYS TO SLOPE AWAY FROM THE BUILDING. MAXIMUM WALKWAY SLOPES ALLOWED BY CODE ARE 5% IN THE DIRECTION OF TRAVEL WITH A 2% CROSS SLOPE. LANDING TO BE LEVEL AT MAX. 2% SLOPE FOR FULL WIDTH OF REQUIRED DOOR MANEUVERING CLEARANCES. 1 2 3 NOTE: REFER TO ADDITIONAL GENERAL CONSTRUCTION NOTES ON G-101 1.G.C. SHALL CLEAN AND PREP ALL SURFACES TO RECEIVE NEW FINISHES AS REQUIRED BY M.F.G.R.'S STANDARD SPECS, RECOMMENDATIONS AND DETAILS - TYPICAL. 2.THE G.C. SHALL INSTALL ALL NEW INTERIOR FINISHES AT ALL SURFACES IN CONFORMANCE TO LOCAL BLDG CODES. 3.THE G.C. MUST NOTIFY THE ARCHITECT OF ANY PROPOSED CHANGES BASED UPON THE DISCOVERY OF LATENT CONDITIONS OR DISCREPANCIES BEFORE PROCEEDING W/ THE WORK, INCLUDING RELOCATION OF, OR ADDITIONS TO, PROPOSED FLOOR & WALL OPENINGS. 4.G.C. TO PATCH AND/OR REPAIR EXISTING WALL FINISHES TO REMAIN AS REQUIRED DUE TO CONSTRUCTION ACTIVITIES. MATCH AND BLEND WITH ADJACENT SURFACES AND PREPARE SURFACES TO RECEIVE NEW FINISHES. ALL NEW WORK TO MATCH EXISTING CONSTRUCTION. 5.G.C. IS TO PROVIDE AND COORDINATE SOLID BLOCKING WITH OWNER FOR ALL WALL MOUNTED EQUIPMENT, ACCESSORIES, HANDRAILS, LIGHT FIXTURES, ETC. TO INCLUDE BUT NOT LIMITED TO TOILET FIXTURES, WALL MOUNTED MONITORS, MILLWORK, AND WALL MOUNTED PIN-UP BOARDS. 6.THE G.C. SHALL BE RESPONSIBLE FOR COORDINATING AND PROVIDING FIRE EXTINGUISHER TYPE, LOCATION, QUANTITY, AND A-V FIRE ALARM REQUIREMENTS WITH THE ALL LOCAL CODES. 7.THE G.C. SHALL COORD. ALL FLOORING AND FINISHES W/ THE FINISH PLAN. SUBMIT ALL SHOP DRAWINGS, SAMPLES, CATALOG CUTS ETC., INCLUDING COLOR CHARTS FOR PAINTS AND STAINS FOR ALL EXTERIOR AND INTERIOR FINISHES, TO THE ARCHITECT FOR SELECTION, REVIEW AND APPROVAL PRIOR TO FABRICATION OR INSTALLATION. 8.THE G.C. SHALL SUPPLY ALL LABOR & MATERIALS FOR A COMPLETE JOB UNLESS OTHERWISE DESIGNATED AS THE OWNER'S RESPONSIBILITY. ROOM NAME ### DRAWING NOTES: 1.DRAWINGS ARE NOT TO BE SCALED. ALL WORK, LINES AND LEVELS SHALL BE LAID OUT BY WRITTEN DIMENSIONS. PARTITION DIMENSIONS ARE FROM FINISH FACE TO FINISH FACE. ANY DEVIATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. ALL DEVIATIONS SHALL BE CORRECTED BY THE CONTRACTOR BEFORE HE BEGINS HIS PORTION OF THE WORK. START OF WORK INDICATES ACCEPTANCE OF CONDITIONS. 2.G.C. MUST FIELD-VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE WORK. NOTIFY THE ARCHITECT REGARDING ANY DISCREPANCIES. 3.ANY GRADE OR ELEVATIONS SHOWN SHALL BE FIELD VERIFIED AND COORDINATED. G.C. TO FIELD VERIFY PRIOR TO START OF ANY WORK & REPORT TO THE ARCHITECT AND OWNER ANY DISCREPANCIES, TYP. PROVIDE NEW CRAWLSPACE FLUSH MOUNTED, INSULATED ACCESS DOOR WITH GALVANIZED STEEL ACCESS SHIPS LADDER. ACCESS DOOR TO BE LOCKABLE AND ALARMED. COORDINATE WITH TENANT SECURITY VENDOR. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION. G.C. TO COORDINATE FINAL SIZE AND LOCATION WITH MECHANICAL CONTRACTOR AND TENANT. WALLS TO BE ALIGNED. G.C. TO FIELD VERIFY AND NOTIFY ARCHITECT IF EXISTING FIELD CONDITION DIFFERS FROM PROPOSED FLOOR PLAN LAYOUT. PROVIDE 3/4" PLYWOOD WITH WALL BLOCKING AS REQUIRED AT BACK WALL OF I.T. CLOSET FOR EQUIPMENT MOUNTING. COORDINATE EXTENT OF PLYWOOD BACKING WITH TENANT'S SECURITY VENDOR. EXTERIOR WALL INFILL TO MATCH ADJACENT 2X4 WALL CONSTRUCTION WITH 2LB. CLOSED-CELL SPRAY FOAM INSULATION AND 5/8" GYPSUM WALL BOARD ON INTERIOR SIDE. EXTERIOR SIDE TO RECEIVE NEW VINYL SIDING ON "TYVEK" COMMERCIAL BUILDING WRAP OVER 1/2" EXTERIOR GRADE SHEATHING. G.C. TO ENSURE WALL INFILL MEETS 2015 IECC CODE REQUIREMENTS. REFER TO EXTERIOR ELEVATION FOR EXTENT OF VINYL SIDING. EXTERIOR WALL CONSTRUCTION TO BE DOUBLE 2X4 WALL STUDS @ 16" O.C. W/ 2LB. CLOSED-CELL SPRAY FOAM INSULATION & 5/8" GYPSUM WALL BOARD ON INTERIOR SIDE. EXTERIOR SIDE TO RECEIVE RECLAIMED WOOD SIDING ON P.T. STRAPPING @ 16" O.C., OVER "TYVEK" COMMERCIAL BUILDING WRAP, OVER 1/2" EXTERIOR GRADE SHEATHING. G.C. TO ENSURE WALL INFILL MEETS 2015 IECC CODE REQUIREMENTS. REFER TO FRAMING PLANS FOR EXTENT OF DOUBLE 2X4 WALL STUDS AND EXTERIOR ELEVATION FOR EXTENT OF RECLAIMED WOOD SIDING. 5 GENERAL NOTES: 6 7 8 91A 4 G.C. TO PROVIDE ASPHALT INFILL FROM EXISTING DRIVEWAY TO NEW CONCRETE LANDINGS AND WALKWAYS. MATCH AND BLEND WITH EXISTING ASPHALT AND PROVIDE FLUSH TRANSITIONS BETWEEN NEW AND OLD ASPHALT AND BOTTOM OF NEW CONCRETE WALKWAY. ASPHALT INFILL TO BE 1-1/2" WEARING COURSE OVER 1-1/2" BASE COURSE OVER 8" COMPACTED GRAVEL BASE. ALL LANDSCAPED AREAS DISTURBED BY NEW CONSTRUCTION TO BE RE-LANDSCAPED. DISTURBED GRASS LANDSCAPED AREAS TO BE COVERED WITH MINIMUM 4" LOAM AND SEEDED WITH NATIVE GRASS MIXTURE. COORDINATE LANDSCAPING REQUIREMENTS AND WORK WITH TENANT AND LANDLORD PRIOR TO COMMENCING WORK. G.C. TO FIELD VERIFY EXTENTS OF NOTED AREAS IN PLAN. G.C. TO INSTALL AN ADDITIONAL 2X WOOD STUD TO MATCH EXISTING, CENTERED IN EACH EXISTING STUD BAY. FULLY INSULATE WALL CAVITY WITH 2LB. CLOSED-CELL SPRAY-FOAM INSULATION AND PROVIDE AMICO SECURITY MESH, ASM .75-9F MIN. ON "INSIDE FACE" OF WALL STUDS W/ SECURA CLIPS @ 12" O.C.. 5/8" GYPSUM WALL BOARD TO BE INSTALLED OVER SECURITY MESH. G.C. TO ENSURE NEW WALL CONSTRUCTION MEETS 2015 IECC CODE REQUIREMENTS. PROVIDE NEW P.T. HANDRAIL AND BALUSTERS AND INSTALL PER STATE AND LOCAL BUILDING CODES. MODIFY EXISTING HANDRAILS TO MEET CURRENT CODE REQUIREMENTS. REPAIR EXISTING ROOF DECK AND RAILINGS AS REQUIRED AND PROVIDE NEW PAINT AS SELECTED BY ARCHITECT. COORDINATE ALL WORK WITH TENANT AND LANDLORD PRIOR TO COMMENCING. 10 11 12 EXISTING 2X4 WALL STUDS TO RECEIVE FULL HEIGHT SISTER STUDS. G.C. TO PROVIDE SISTER STUDS @ FIRST AND SECOND FLOOR LEVELS OF STAIR EXTERIOR WALLS & INSULATE WALLS W/ 2LB. CLOSED-CELL SPRAY FOAM INSULATION. PROVIDE 5/8" GYPSUM WALL BOARD ON INTERIOR SIDE. EXTERIOR SIDE TO RECEIVE NEW VINYL SIDING ON "TYVEK" COMMERCIAL BUILDING WRAP. G.C. TO ENSURE WALL INFILL MEETS 2015 IECC CODE REQUIREMENTS. REFER TO FRAMING PLANS FOR EXTENT OF 2X4 SISTER WALL STUDS & EXTERIOR ELEVATION FOR EXTENT OF VINYL SIDING. 13 ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) ENTRY / EXIT VESTIBULE 100 SECURITY OFFICE 101 SALES AREA 102 EXISTING ELEC. RM 103 JAN. CL. 105 STAIR 1 103A 2 EXISTING STORAGE SHED (N.I.C.) HALL 104 POS STATIONS 102A HALL 103A 103A 1 103A 3 103A 4 100 1 100 2 100 3 101 1 105 1 ACCESSIBLE RESTROOM 106 106 1 STR 1 SCALE: 1 FIRST FLOOR PLAN 1/4" = 1'-0" 1 A400 2 A400 3 A300 2 A300 1 A300 X A A UP B 1 A401 5'-0" MIN. LANDING ± 12'-6"10'-0" LANDING5'-0" MIN.LANDING5'-0" MIN.LANDING27'-6" SLOPE DN 1:20 MAX. 4'-0" CLEAR STEPEQ.EQ.DN1A 1 1 12 1 4 5 5 5 5'-6 1/2"R.O.± 9 1/2"5-1/2" x 5-1/2" PSL POST. REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION, TYP. EACH SIDE 3-1/2" x 3-1/2" PSL POST. REFER TO FRAMING PLAN FOR ADDTL. INFORMATION, TYP. EACH SIDE B G.C. TO PROVIDE FLUSH TRANSITION BETWEEN CONCRETE LANDING AND ASPHALT PAVING 4 A1 A1 A1 A1 A1 33 A1 B B2 B2 A1 B A4 A4 A4 A4 B1 B1 C CEQ.EQ.℄7'-10"HOLD± 5'-0"3'-0"9'-5" 4'-0" ℄14'-2" 102 1 7'-0"HOLD± 5'-9"4'-0" ℄ 2'-4 1/2" HOLD A1 2'-7 1/2" R.O. 2'-4 1/2" HOLD ℄ 2'-10"7'-8 1/2"4'-0"CLEAR MIN.1'-1"± 7'-8"7'-0" HOLD 7'-0" 8 6'-6"6'-6 1/2" R.O. 1'-2"3'-0 1/2" R.O. 7'-0" 4 1/2" 9 9 3 A400 EXISTING CMU FOUNDATION WALL BELOW EXISTING CMU FOUNDATION WALL BUMP-OUT. PROVIDE STAINED SILL & PAINTED APRON. FINISH STAIN AND COLOR TBD. N DESIGN NORTH 5'-0" A1 101A 1 EQ.EQ.℄ I.T. CL. 101A10 11 11 12 12 12 SIM. SIM. 13 SCALE: 2 SECOND FLOOR PLAN 1/4" = 1'-0" 1 A400 2 A400 STOR. CL. 201 CORRIDOR 200 PACKAGING 202 BATH 205 BREAK ROOM 204 COUNTING ROOM 206 VAULT 207 206 1 200A 1 204 2 205 1 3 A300 2 A300 1 A300 X X X X X X X X8'-11 1/2"DN ± 11'-6 1/2"7'-2 1/2" HOLD ± 14'-9 3/4"4'-2"6'-6"4'-4" HOLD C A A A2 A1 EXISTING OUTDOOR DECK 2 A401 207 1 7'-0" HOLD C 2 1 6 6 7 ± 6'-0"GC TO VIFSTAIR 1 OFFICE 203 201 1 204 1 202 1 203 1 200 1 A5 ± 12'-0 1/2"4'-5"7'-3"± 11'-6 1/2"9'-10 1/2"± 19'-6" ℄3'-0"± 11'-0 1/2"12'-0 1/2"HOLD4'-0"CLEAR MIN.4'-0 1/2"4'-0"CLEARMIN.5'-6"4'-0" CLEAR MIN. ℄10'-5 1/2" A1 A A1 A1 A1 EXTENT OF VAULT ROOM SECURED FLOOR FRAMING WITH ADDITIONAL FLOOR JOISTS AND AMICO SECURITY MESH. REFER TO FLOOR FRAMING PLAN FOR ADDITIONAL INFORMATION N DESIGN NORTH JAN. CL. 200A A2 A2REF.DW2'-6" HOLD 13 13 1313 SIM.SIM. JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-103 PARTITION SCHEDULE.dwgLast save: Oct 10, 2019 - 3:15pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 102 CONSTRUCTION FLOOR PLANS, AND NOTES PARTITION TYPES: ACOUSTICAL SEALANT BOTH SIDES CONTINUOUS SOUND ATTENUATION BATTS. 3 1/2" WOOD STUDS @ 16" O.C. W/ 5/8" G.W.B. FULL HEIGHT ON BOTH SIDES BASE AS SCHEDULED BOTH SIDES, TYP. CARRY STUDS TO U.S. OF STRUCTURE ABOVE CEILING PLANE WHERE IT OCCURS, REFER TO RCP FOR CEILING INFO. SCALE:UL DES. NO.: STC RATING: FULL-HEIGHT PARTITION 3/4" = 1'-0"N/A N/A A ACOUSTICAL SEALANT BOTH SIDES A1 SAME AS TYPE A, BUT WITH NO SOUND ATTENUATION BATTS A2 SAME AS TYPE A, BUT WITH MOISTURE RESISTANT G.W.B. ON BOTH SIDES. A4 SAME AS TYPE A, BUT WITH MOISTURE RESISTANT G.W.B. ON WET SIDE ONLY. 3 1/2" WOOD STUDS @ 16" O.C. W/ 5/8" G.W.B. FULL HEIGHT ON ONE SIDE ONLY (12" O.C. @ BEARING WALLS) BASE AS SCHEDULED ONE SIDE ONLY CARRY STUDS TO U.S. OF STRUCTURE ABOVE CEILING PLANE WHERE IT OCCURS, REFER TO RCP FOR CEILING INFO. SCALE:UL DES. NO.: STC RATING: FULL-HEIGHT PARTITION 3/4" = 1'-0"N/A N/A B 3 1/2" WOOD STUDS @ 12" O.C. W/ 5/8" G.W.B. FULL HEIGHT ON BOTH SIDES BASE AS SCHEDULED BOTH SIDES, TYP. CARRY STUDS TO U.S. OF STRUCTURE ABOVE CEILING PLANE WHERE IT OCCURS, REFER TO RCP FOR CEILING INFO. SCALE:UL DES. NO.: STC RATING: TYP. VAULT PARTITION 3/4" = 1'-0"N/A N/A C VAULT SIDE AMICO SECURITY MESH, ASM .75-9F MIN. ON "OUTSIDE" OF WALL STUDS W/ SECURA CLIPS @ 12" O.C. 5/8" GYPSUM WALL BOARD ON 1X3 WOOD STRAPPING @ 12" O.C. AMICO SECURITY MESH, ASM .75-9F MIN. ON "UNDERSIDE" OF CEILING JOISTS WITH SECURA CLIPS 12" O.C. A3 SAME AS TYPE A, BUT WITH NO SOUND ATTENUATION BATTS AND WITH MOISTURE RESISTANT G.W.B. ON BOTH SIDES. A5 SAME AS TYPE A, BUT WITH NO SOUND ATTENUATION BATTS AND WITH MOISTURE RESISTANT G.W.B. ON WET SIDE ONLY. B1 SAME AS TYPE B, BUT WITH MOISTURE RESISTANT G.W.B. ON WET SIDE. B2 SIMILAR TO TYPE B, BUT WITH NO GYPSUM WALL BOARD JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-103 PARTITION SCHEDULE.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 103 PARTITION SCHEDULE AND PLAN DETAILS 7'-6" A.F.F. A.C.P. SCALE: 2 SECOND FLOOR REFLECTED CEILING PLAN 1/4" = 1'-0" STORAGE CLOSET 201 OFFICE 203 BATH 205 BREAK ROOM 204 COUNTING ROOM 206 VAULT 207 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1L-1 L-1L-1 L-1 L-1 L-8 L-6 ± 7'-9" A.F.F. G.W.B. ± 7'-9" A.F.F. G.W.B. ± 7'-9" A.F.F. GWB ± 7'-9" A.F.F. G.W.B.L-1 L-1L-1 L-1 L-1L-1 PACKAGING 202 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1L-1 L-1 ± 7'-9" A.F.F. G.W.B. ± 7'-9" A.F.F. G.W.B. CORRIDOR 200 STAIR 1 ST1 7'-6" A.F.F. A.C.P. ± 7'-9" A.F.F. G.W.B. 3 N DESIGN NORTHL-9L-9L-9L-9 W L-1 JANITOR CLOSET 200A ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) SCALE: 1 FIRST FLOOR REFLECTED CEILING PLAN 1/4" = 1'-0" SALES AREA 102 EXISTING ELEC. RM 103 EXISTING STORAGE SHED (N.I.C.) HALL 104 ENTRY / EXIT VESTIBULE 100 EXISTING A.C.P. 8'-0" A.F.F. G.W.B. L-1 L-1 L-1L-1 L-3 L-4 L-5L-5 L-1 L-4L-4 L-7L-7 IT CLOSET 101A POS STATIONS 102A HALL 103A WD-3 WD-3 8'-0" A.F.F. G.W.B. STAIR 1 ST1 JANITOR CLOSET 105 ACCESSIBLE RESTROOM 106 L-2 L-2 L-2 L-2 L-2 L-2 L-2 L-2 L-7 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 8'-0" A.F.F. A.C.P. L-6 L-8 L-2 L-2 L-2 L-2 L-2L-2 L-2 L-2 L-5 L-5 L-5 L-1 L-3 L-1L-1L-3 L-3 L-3 L-3 ± 8'-9" A.F.F. WOOD PLANK ± 8'-9" A.F.F. WOOD PLANK L-1L-1 L-3 L-1L-1 L-1L-1 L-1L-1 L-3 1 (OPEN TO STRUCTURE ABOVE TO REMAIN) 7'-6" A.F.F. G.W.B. 8'-0" A.F.F. G.W.B. 2 2 2 N DESIGN NORTH L-1 L-1 L-1 SECURITY OFFICE 101 L-9 L-9 W W W GENERAL REFLECTED CEILING PLAN NOTES: 1.LIGHTING SHOWN ON THIS PLAN IS DIAGRAMMATIC AND FOR DESIGN INTENT ONLY. G.C. TO COORD. WITH D/B ELECTRICAL, PLUMBING, HVAC, AND ELECTRICAL/FIRE ALARM SYSTEM DRAWINGS FOR FIXTURE, DEVICES AND EQUIPMENT LOCATIONS, TYPES, REQUIREMENTS AND SPECIFICATIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 2.THE G.C. SHALL COORDINATE THE WORK OF ALL OWNER'S VENDORS, SUB-C'S AND D/B SUBCONTRACTORS FOR ABOVE-CEILING WORK INCLUDING, BUT NOT LIMITED TO: CEILING MOUNTED WORK AND DUCTWORK, EQUIPMENT, DEVICES, SECURITY CAMERAS, AS WELL AS FIRE ALARM SYSTEM: E.G. SIGNALING & DETECTION. 3.REFER TO D/B ENGINEERED ELECTRICAL/FIRE ALARM DRAWINGS FOR FINAL EMERGENCY LIGHT, EXIT SIGN AND LIGHT LOCATIONS. G.C. TO COORDINATE WITH TENANT ON REQUIRED ZONING AND CONTROLS PRIOR TO PROCEEDING WITH THE D/B SUBCONTRACTOR. 4.D/B HVAC ENGINEER IS RESPONSIBLE FOR DESIGN, LAYOUT, AND ALL INSTALLATION AND COORDINATION W/ OTHER TRADES AS WELL AS CONFORMANCE TO ALL APPLICABLE CODES. NOTIFY ARCHITECT AND OWNER REGARDING ANY UL DESIGN RATING ISSUES. 5.CEILING HEIGHTS SHALL BE NOT LESS THAN 7'-6" A.F.F. REFER TO THE REFLECTED CEILING PLANS FOR AREAS OF DIFFERING CEILING HEIGHTS. 6.G.C. TO COORDINATE WITH TENANT REGARDING FINAL MFGR, FIXTURE TYPES, AND LOCATIONS FOR HVAC EQUIPMENT. 7.INSTALL MATERIALS AND SUSPENSION SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS, AS WELL AS ASTM C 636. COORDINATE THE INSTALLATION WITH THE MEP, AND ELECTRICAL WORK TO ENSURE PROPER LOCATIONS. 8.LEVEL THE CEILING TO WITHIN 1/8" IN 10 FEET IN BOTH DIRECTIONS. SCRIBE AND CUT PANELS TO FIT ACCURATELY. MEASURE AND LAYOUT TO AVOID LESS-THAN-HALF PANEL UNITS TO THE GREATEST EXTENT POSSIBLE. (6" MIN.) ADJUST, CLEAN, AND TOUCH-UP ALL SYSTEM COMPONENTS. 9.ACOUSTICAL CEILING PANEL SHALL BE INSTALLED WITH CUT REVEALS AT ALL PERIMETER WALLS. 10.PROVIDE ALL MOLDINGS, TRIM, CLIPS, SEALANT, ACCESSORIES, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION OF ALL CEILING SYSTEMS PER MFGR'S SPECIFICATIONS AND RECOMMENDATIONS. 11.PROVIDE HOLD-DOWN CLIPS FOR CEILING PANELS AT ALL RATED LOCATIONS. 12.PROVIDE OWNER WITH WRAPPED AND LABELED MAINTENANCE STOCK OF NEW MATERIAL EQUAL TO 2% OF CEILING PANELS AND SUSPENSION SYSTEM INSTALLED. STORE AS PER OWNERS & REP DIRECTIONS. 13.PROVIDE 10 YEAR WARRANTY ON ALL SUSPENSION ACP CEILING SYSTEMS. 14.PROVIDE ALUMINUM GRID SYSTEM AT ALL WET LOCATIONS. NOTES: REFLECTED CEILING PLAN LEGEND USAI LIGHTING: BeveLED 4.5" Ø LED RECESSED LIGHT FIXTURE B4RDF. TRIMMED. 3500k. 0-10V DIM. IC RATED LBL BA1082BLAB TAE BLACK/ AGED BRASS VANITY FIXTURE 1.FINAL SPECIFICATION FOR EXIT SIGNAGE AND EMERGENCY LIGHTING TO BE REVIEWED AND APPROVED BY ARCHITECT AND OWNER 2.G.C. TO COORDINATE ALL SMOKE DETECTORS, EMERGENCY LIGHTING, & FIRE ALARM EQUIPMENT LOCATIONS WITH D/B FIRE ALARM SUBCONTRACTOR. 3.D/B SUBCONTRACTOR TO COORD. HEAT & SMOKE DETECTORS AS REQUIRED BY LOCAL FIRE DEPT. 4.W M= WALL MOUNTED, SM = SURFACE MOUNTED LIGHT FIXTURES 5.G.C. TO PROVIDE CUT SHEETS TO ARCHITECT FOR ALL LIGHTING PRIOR TO ORDERING 6.ALL LED LIGHTING TO BE 3500K 7.ALL RECESSED LIGHT FIXTURES TO BE IC RATED 8.SECURITY CAMERAS: LOCATIONS & QUANTITY ARE FOR PRICING PURPOSES. FINAL LOCATIONS AND QUANTITY MAY CHANGE. L-4 WAC LIGHTING: SUMMIT LED 208-30 LUMINAIRE AND TRACK SYSTEM. TROY LIGHTING LED MINI PENDANT FL4896. HAND WORKED IRON. L-5 L-2 L-1 4" Ø LED RECESSED EXTERIOR LIGHT FIXTURE TBD. PROVIDE EXTERIOR MOUNTING ACCESSORIES AND IC RATING L-3 L-7 NUTONE ULTRAPRO SERIES EXHAUST FAN L-8 L-6 USAI LIGHTING: BeveLED 4.5" Ø LED RECESSED LIGHT FIXTURE B4RDM. MILLWORK. 3500k. 0-10V DIM. IC RATED USAI LIGHTING: BeveLED 4.5" Ø LED RECESSED LIGHT FIXTURE B4RW.. WALL WASH. 3500k. 0-10V DIM. IC RATED NEW GWB CEILING OR SOFFIT, PAINTED NEW OR EMERGENCY EXIT SIGN - LED, WALL OR SOFFIT MOUNTED (W = WALL-MOUNTED) (N = NEW, E = EXISTING) 2X2 ACOUSTICAL CEILING PANEL W/ 9/16" SUSPENSION SYSTEM N-W NEW OR EMERGENCY LIGHTING (N = NEW) N NEW MOTION SENSORS, COORDINATE W/ SECURITY VENDOR PLANS NEW SECURITY CAMERA, COORDINATE W/ SECURITY VENDOR PLANS 360MD RECLAIMED WOOK PLANK: WD-3 REFLECTED CEILING PLAN KEY NOTES EXISTING LIGHTING TO REMAIN. NEW LIGHT FIXTURE TO BE INSTALLED AT EXISTING LIGHT FIXTURE LOCATION. PROVIDE NEW ATTIC INSULATED ACCESS DOOR. ACCESS DOOR TO BE LOCKABLE AND ALARMED. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION. G.C. TO COORDINATE FINAL SIZE AND LOCATION W/ MECHANICAL CONTRACTOR AND OWNER. 1 2 3 L-9 LUMENPULSE LUMANFACADE EXTERIOR LED FIXTURE. LOGR. 48", 300K, WAMR6, BK JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-200 REFLECTED CEILING PLANS, NOTES, & LEGENDS.dwgLast save: Oct 10, 2019 - 2:10pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 200 REFLECTED CEILING PLANS, NOTES, & LEGENDS HEMPEST THE SCALE: 1 CONZ ST. ELEVATION 1/4" = 1'-0" 2 A400 X X X X 0'-0" A.F.F. FIRST FINISH FLOOR ± 9'-10" A.F.F. SECOND FINISH FLOOR - 6'-6" A.F.F. ± CRAWLSPACE SLAB FINISH EXISTING DORMER TO REMAIN, TYP. EXISTING ROOF SHINGLES TO REMAIN PROVIDE NEW ALUMINUM GUTTER AND DOWNSPOUT TO MATCH EXISTING. FINISH COLOR TBD. 1X6 PVC CORNER BOARD W/ BUILT-IN "J" CHANNEL, TYP., FINISH COLOR TBD. FINISH GRADE VINYL "CLAPBOARD" SIDING WITH 4" EXPOSURE, OVER "TYVEK" COMMERCIAL BUILDING WRAP OVER EXISTING SHEATHING, TYPICAL. FINISH COLOR TBD. RECLAIMED WOOD SIDING RAINSCREEN ON P.T. STRAPPING @ 16" O.C., OVER "TYVEK" COMMERCIAL BUILDING WRAP, OVER 1/2" EXTERIOR GRADE SHEATHING. REFER TO FINISH SCHEDULE FOR SPECIFICATIONS. 1X8 PVC AT DOOR JAMBS WITH BUILT-IN "J" CHANNEL AND 1X16 PVC AT DOOR HEAD TIGHT TO SOFFIT ABOVE. G.C. TO FIELD VERIFY HEIGHT. FINISH COLOR TBD. NEW CONCRETE LANDING AND WALKWAY, MAX 1:20 SLOPE IN DIRECTION OF TRAVEL AND 2% CROSS SLOPE - REFER TO FLOOR PLAN FOR ADDTL. INFORMATION B 100 1 WINDOW INSTALLED WITH 1X6 PVC WINDOW SURROUND W/ BUILT-IN "J" CHANNEL, TYP., FINISH COLOR TBD. G.C. TO INSTALL TENANT PROVIDED EXTERIOR BUILDING SIGN. G.C. TO VERIFY W/ TENANT, WEIGHT OF SIGN AND PROVIDE CONCEALED BRACKETS & ALL NECESSARY BLOCKING TO SUPPORT SIGN. ARCHITECT TO REVIEW W/ STRUCTURAL ENGINEER PRIOR TO SIGN INSTALLATION. COORDINATE ALL WORK WITH OWNER AND TENANT, TYP. "L-9" EXTERIOR LINEAR LED LIGHT FIXTURES. G.C. TO PROVIDE POWER & ALL NECESSARY SUPPORT BLOCKING AS REQUIRED. COORDINATE ALL WORK WITH OWNER AND TENANT, TYP. 1x6 PVC FREEZE TRIM BOARD @ VINYL SIDING ONLY. FINISH COLOR TBD. 4'-0" HOLD 7'-6"± 14'-8" G.C. TO V.I.F. ± 26'-2" G.C. TO V.I.F. ± 16'-4 1/2" G.C. TO V.I.F. G.C. TO MITER RECLAIMED WOOD SIDING AT OUTSIDE CORNER, TYP. G.C.TO PROVIDE BUILT-IN "J" CHANNEL AT ALL RECLAIMED WOOD SIDING END PIECES IF REQUIRED TO CONCEAL VINYL SIDING TERMINATION "J" CHANNEL. PROVIDE EXTERIOR GRADE CAULKING AS REQUIRED. FINISH CAULKING COLOR TBD. HEMPEST THE SCALE: 2 WEST SIDE ELEVATION 1/4" = 1'-0" 1 A400 X X 0'-0" A.F.F. FIRST FINISH FLOOR ± 9'-10" A.F.F. SECOND FINISH FLOOR ± 22'-2" EXTENT OF VINYL REPLACEMENT EXISTING DORMER BEYOND TO REMAIN, TYP. EXISTING RAKE BOARDS TO REMAIN. PATCH, REPAIR AND/OR REPLACE BOARDS AS REQUIRED AND PREP TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD. PROVIDE NEW ALUMINUM GUTTER AND DOWNSPOUT TO MATCH EXISTING. FINISH COLOR TBD. EXISTING ROOF SHINGLES TO REMAIN, TYP. EXISTING ATTIC LOUVER VENT TO REMAIN. PATCH AND/OR REPAIR AS REQUIRED AND PREP TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD. EXISTING SHED DORMER BEYOND TO REMAIN. EXISTING VINYL SIDING AT REAR FACE OF DORMER TO REMAIN 1X6 PVC WINDOW SURROUND WITH BUILT-IN "J" CHANNEL, TYPICAL. FINISH COLOR TBD. FINISH GRADE 1X6 PVC CORNER BOARD WITH BUILT-IN "J" CHANNEL, TYP., FINISH COLOR TBD. VINYL "CLAPBOARD" SIDING WITH 4" EXPOSURE, OVER "TYVEK" COMMERCIAL BUILDING WRAP OVER EXISTING SHEATHING, TYPICAL. FINISH COLOR TBD. "L-9" EXTERIOR LINEAR LED LIGHT FIXTURES, MOUNTED ON WHITE PVC TRIM BLOCKS WITH INTEGRAL REVEAL ON ALL EDGES TO ACCEPT SIDING. G.C. TO PROVIDE POWER & ALL NECESSARY SUPPORT BLOCKING AS REQUIRED. COORDINATE ALL WORK WITH OWNER AND TENANT, TYP. G.C. TO INSTALL TENANT PROVIDED EXTERIOR BUILDING SIGN. G.C. TO VERIFY W/ TENANT, WEIGHT OF SIGN AND PROVIDE CONCEALED BRACKETS & ALL NECESSARY BLOCKING TO SUPPORT SIGN. ARCHITECT TO REVIEW W/ STRUCTURAL ENGINEER PRIOR TO SIGN INSTALLATION. COORDINATE ALL WORK WITH OWNER AND TENANT, TYP. 1x6 PVC FREEZE TRIM BOARD @ VINYL SIDING ONLY. FINISH COLOR TBD. HEMPEST THE SCALE: 3 MAPLE AVE. ELEVATION 1/4" = 1'-0" 1 A400 X X A A 0'-0" A.F.F. FIRST FINISH FLOOR ± 9'-10" A.F.F. SECOND FINISH FLOOR - 6'-6" A.F.F. ± CRAWLSPACE SLAB FINISH INFILL EXISTING CMU WALL OPENING TO MATCH EXISTING. PREP EXPOSED CMU WALL TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD. 4'-0" HOLD EXISTING DORMER BEYOND TO REMAIN, TYP. EXISTING RAKE BOARDS TO REMAIN. PATCH, REPAIR AND/OR REPLACE BOARDS AS REQUIRED AND PREP TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD. EXISTING ROOF SHINGLES TO REMAIN, TYP. PROVIDE NEW ALUMINUM GUTTER AND DOWNSPOUT TO MATCH EXISTING. FINISH COLOR TBD. RECLAIMED WOOD SIDING RAINSCREEN ON P.T. STRAPPING @ 16" O.C., OVER "TYVEK" COMMERCIAL BUILDING WRAP, OVER 1/2" EXTERIOR GRADE SHEATHING. REFER TO FINISH SCHEDULE FOR SPECIFICATIONS. FINISH GRADE EXISTING ATTIC LOUVER VENT TO REMAIN. PATCH AND/OR REPAIR AS REQUIRED AND PREP TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD. EXISTING SHED DORMER TO REMAIN. EXISTING VINYL SIDING AT REAR FACE OF DORMER TO REMAIN 1X6 PVC WINDOW SURROUND W/ BUILT-IN "J" CHANNEL, TYP. FINISH COLOR TBD. VINYL "CLAPBOARD" SIDING WITH 4" EXPOSURE, OVER "TYVEK" COMMERCIAL BUILDING WRAP OVER EXISTING SHEATHING, TYPICAL. FINISH COLOR TBD. 1X6 PVC TRIM BOARD WITH BUILT-IN "J" CHANNEL, TYP., FINISH COLOR TBD. WINDOW INSTALLED WITH 1X6 PVC WINDOW SURROUND WITH BUILT-IN "J" CHANNEL, TYP., FINISH COLOR TBD. SIDING INFILL TO MATCH EXISTING. G.C. TO REMOVE EXISTING SIDING PANELS AS REQUIRED TO ALLOW FOR A FULL PANEL TO BE INSTALLED AND A CONTINUOUS EXISTING PATTERN MAINTAINED. EXISTING EXTERIOR SIDING TO REMAIN. PREP SURFACES TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD EXISTING CORNER BOARD TO REMAIN. PREP SURFACES TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD. EXISTING EXTERIOR SIDING TO REMAIN. PREP SURFACES TO RECEIVE NEW EXTERIOR GRADE PAINT. FINISH COLOR TBD "L-9" EXTERIOR LINEAR LED LIGHT FIXTURES, MOUNTED ON WHITE PVC TRIM BLOCKS WITH INTEGRAL REVEAL ON ALL EDGES TO ACCEPT SIDING. G.C. TO PROVIDE POWER & ALL NECESSARY SUPPORT BLOCKING AS REQUIRED. COORDINATE ALL WORK WITH OWNER AND TENANT, TYP. G.C. TO INSTALL TENANT PROVIDED EXTERIOR BUILDING SIGN. G.C. TO VERIFY W/ TENANT, WEIGHT OF SIGN AND PROVIDE CONCEALED BRACKETS & ALL NECESSARY BLOCKING TO SUPPORT SIGN. ARCHITECT TO REVIEW W/ STRUCTURAL ENGINEER PRIOR TO SIGN INSTALLATION. COORDINATE ALL WORK WITH OWNER AND TENANT, TYP. PROVIDE BREAK METAL FLASHING AT VINYL & RECLAIMED WOOD SIDING TRANSITION. FINISH COLOR TBD. G.C.TO PROVIDE BUILT-IN "J" CHANNEL AT ALL RECLAIMED WOOD SIDING END PIECES IF REQUIRED TO CONCEAL VINYL SIDING TERMINATION "J" CHANNEL. PROVIDE EXTERIOR GRADE CAULKING AS REQUIRED. FINISH CAULKING COLOR TBD. JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-300 EXTERIOR ELEVATIONS & NOTES.dwgLast save: Oct 10, 2019 - 2:11pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 300 EXTERIOR ELEVATIONS AND NOTES SCALE: 1 BUILDING SECTION 1/4" = 1'-0" 2 A400 1 A402 STAIR 1 CORRIDOR 200 201 1 ACCESSIBLE RESTROOM 106 100 3 C HALL 104 EXISTING CMU FOUNDATION WALLS TO REMAIN. REPAIR WALL AS REQUIRED AND GROUT SOLID, TYP. OF (4) - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. EXISTING EXTERIOR WALL TO REMAIN. REPAIR AND/OR PATCH GWB AS REQUIRED, TYP. VINYL "CLAPBOARD" SIDING - REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. 1/2" GYPSUM WALL BOARD ON 1X3 WOOD STRAPPING @ 12" O.C. ON 2X6 WOOD CEILING JOISTS @ 16" O.C. EXISTING RAKE BOARDS TO REMAIN. PATCH, REPAIR AND/OR REPLACE BOARDS AS REQUIRED - REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. EXISTING ROOF SHINGLES TO REMAIN, TYP. 0'-0" A.F.F. FIRST FINISH FLOOR ± 9'-10" A.F.F. SECOND FINISH FLOOR - 6'-6" A.F.F. CRAWLSPACE SLAB FINISH 3-1/2" DIA. LALLY COLUMN ON REINF. CONC. FOOTING - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. 3" CONC. RAT SLAB - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. 2X10 WOOD JOISTS @ 16" O.C. - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. BUILT-UP GIRDER - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. 9 1/2" R30 KRAFT FACED F.G. INSUL. EXISTING WOOD JOISTS TO REMAIN - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. EXISTING FOUNDATION WALL TO REMAIN 2X4 @ 16" O.C. NON-BEARING PARTITION - REF. PARTITION TYPES, TYP. (2) 2X12 FLUSH FRAMED HEADER - REFER TO FRAMING PLAN FOR ADDTL. INFORMATION. VINYL "CLAPBOARD" SIDING - REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. EXISTING RAKE BOARDS TO REMAIN. PATCH, REPAIR AND/OR REPLACE BOARDS AS REQUIRED - REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. 12" R38 KRAFT FACED F.G. INSULATION 12" R38 KRAFT FACED F.G. INSULATION EXISTING EXTERIOR WALL TO REMAIN. REFER TO FLOOR AND FRAMING PLAN FOR ADDITIONAL INFORMATION. NEW FLOOR FRAMING TO MATCH ELEVATION OF EXISTING FLOOR FRAMING TO REMAIN 202 1 OFFICE 203 100 2 101 1 JANITOR CLOSET 105 1/2" GYPSUM WALL BOARD ON 1X3 WOOD STRAPPING @ 12" O.C. ACOUSTICAL CEILING TILE, REF. CEILING PLAN, TYP. 1/2" GYPSUM WALL BOARD ON 1X3 WOOD STRAPPING @ 12" O.C. INTERIOR STAIR - REFER TO ENLARGED PLAN AND SECTION FOR ADDITIONAL INFORMATION 200 1 ATTIC INSUL. ACCESS DOOR. REFER TO DOOR SCHED. FOR ADDTL. INFO. G.C. TO COORD. FINAL SIZE & LOCATION W/ MECH. CONTRACTOR & OWNER. 3/4" T&G PLYWOOD SHEATHING, TYP. REF. TO FINISH PLAN FOR FLOOR FINISH SCALE: 2 BUILDING SECTION 1/4" = 1'-0" 1 A400 103A 1 STR 1 SALES AREA 102 BREAK ROOM 204 EXISTING ROOF SHINGLES TO REMAIN, TYP. EXISTING EXTERIOR WALL TO REMAIN. REPAIR AND/OR PATCH GWB AS REQUIRED, TYP. PROVIDE NEW P.T. HANDRAIL AND BALUSTERS AND INSTALL PER STATE AND LOCAL BUILDING CODES. MODIFY EXISTING HANDRAILS TO MEET CURRENT CODE REQUIREMENTS. REPAIR EXISTING ROOF DECK AND RAILINGS AS REQUIRED AND PROVIDE NEW PAINT AS SELECTED BY ARCHITECT. COORDINATE ALL WORK WITH TENANT AND LANDLORD PRIOR TO COMMENCING. 3/4" T & G PLYWOOD SHEATHING, TYP. - REFER TO FINISH PLAN FOR FLOOR FINISH EXISTING CMU FOUNDATION WALLS TO REMAIN. REPAIR WALL AS REQUIRED AND GROUT SOLID, TYP. OF (4) - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION 3-1/2" DIA. LALLY COLUMN ON REINF. CONC. FOOTING - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION 3" CONC. RAT SLAB - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. 2X10 WOOD JOISTS @ 16" O.C. - REF. TO FRAMING PLAN FOR ADDTL. INFO. BUILT-UP GIRDER - REF. TO FRAMING PLAN FOR ADDTL. INFO. 5 A-400 9 1/2" R30 KRAFT FACED F.G. INSUL. EXISTING WOOD ROOF RAFTERS TO REMAIN 1/2" GYPSUM WALL BOARD ON 1X3 WOOD STRAPPING @ 12" O.C. ON 2X8 WOOD CEILING JOISTS @ 16" O.C. EXISTING CONCRETE SLAB TO REMAIN 2X P.T. WOOD SLEEPERS @ 16" O.C.. G.C. TO ENSURE P.T. WOOD IS USED WHEN IN CONTACT WITH EXISTING CONCRETE SLAB. SLEEPER FLOOR FRAMING ELEVATION TO MATCH MAIN FLOOR ELEVATION. (2) 2X P.T. SILL ON SILL SEALER - ANCHOR BOLT TO FOUNDATION WALL 5 1/2" R21 KRAFT FACED F.G. INSUL. EXISTING FOUNDATION WALL TO REMAIN EXISTING EXTERIOR WALL TO REMAIN. REPAIR AND/OR PATCH GWB AS REQUIRED, TYP. 4 A-400 203 1 STAIR 1 CRAWLSPACE INSUL. ACCESS DOOR. REFER TO DOOR SCHED. FOR ADDTL. INFO. G.C. TO COORD. FINAL SIZE & LOCATION W/ MECH. CONTRACTOR & OWNER. GALVANIZED STEEL, ACCESS SHIPS LADDER. RECLAIMED WOOD CEILING ON 1/2" PLYWOOD SHEATHING, ON EXISTING FLOOR JOISTS - REFER TO CEILING PLAN FOR ADDITIONAL INFORMATION 2X4 @ 16" O.C. NON-BEARING PARTITION - REF. PARTITION TYPES, TYP. 1/2" GYPSUM WALL BOARD ON 1X3 WOOD STRAPPING @ 12" O.C. PROVIDE NEW ALUMINUM GUTTER AND DOWNSPOUT TO MATCH EXISTING. FINISH COLOR TBD. 12" R38 KRAFT FACED F.G. INSULATION "TYVEK" COMMERCIAL BUILDING WRAP, OVER 1/2" EXTERIOR GRADE SHEATHING INTERIOR STAIR - REFER TO ENLARGED PLAN AND SECTION FOR ADDITIONAL INFORMATION 12" R38 KRAFT FACED F.G. INSULATION 3 A401 (2) 1-3/4" x 11-1/4" LVL BEAMS - REFER TO FRAMING PLAN FOR ADDTL. INFORMATION. 102 1 TENANT PROVIDED EXTERIOR BUILDING SIGN. G.C. TO VERIFY W/ TENANT, WEIGHT OF SIGN AND PROVIDE CONCEALED BRACKETS & ALL NECESSARY BLOCKING TO SUPPORT SIGN. ARCHITECT TO REVIEW W/ STRUCTURAL ENGINEER PRIOR TO SIGN INSTALLATION. DOUBLE 2X4 WALL STUDS @ 16" O.C. W/ 2LB. CLOSED-CELL SPRAY FOAM INSULATION. REFER TO FLOOR AND FRAMING PLANS FOR ADDITIONAL INFORMATION 5/8" GYPSUM WALL BOARD, TYP. VINYL SOFFIT PANEL. FINISH COLOR TBD. RECLAIMED WOOD SIDING RAINSCREEN ON P.T. STRAPPING @ 16" O.C.. REFER TO FINISH SCHEDULE FOR SPECIFICATIONS. EXISTING WOOD ROOF RAFTERS TO REMAIN 1/2" GYPSUM WALL BOARD ON 1X3 WOOD STRAPPING @ 12" O.C. ON 2X8 WOOD CEILING JOISTS @ 16" O.C. 12" R38 KRAFT FACED F.G. INSULATION RECLAIMED WOOD CEILING ON 1/2" PLYWOOD SHEATHING, ON EXISTING FLOOR JOISTS - REFER TO CEILING PLAN FOR ADDITIONAL INFORMATION EXISTING FLOOR FRAMING ASSEMBLY TO REMAIN. REFER TO FINISH PLAN FOR FLOOR FINISH (3) 1 3/4" X 14" LVL BEAM BELOW CEILING JOISTS - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. 1/2" GYPSUM WALL BOAD ON WOOD BLOCKING AS REQUIRED 7'-6" A.F.F. G.W.B. FINISH CEILING HEIGHT EXISTING EXTERIOR WALL TO REMAIN. REPAIR AND/OR PATCH GWB AS REQUIRED, TYP. EXTERIOR OUTDOOR DECK - REFER TO FLOOR PLAN FOR ADDITIONAL INFORMATION. EXISTING CMU FOUNDATION WALLS TO REMAIN. REPAIR WALL AS REQUIRED AND GROUT SOLID, TYP. OF (4) - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. 3-1/2" DIA. LALLY COLUMN ON REINF. CONC. FOOTING - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. 2X10 WOOD JOISTS @ 16" O.C. - REF. TO FRAMING PLAN FOR ADDTL. INFO. 9 1/2" R30 KRAFT FACED F.G. INSUL.3/4" T&G PLYWOOD SHEATHING, TYP. REF. TO FINISH PLAN FOR FLOOR FINISH EXISTING CONCRETE SLAB TO REMAIN (2) 2X8 P.T. SILL ON SILL SEALER WITH 1/2" DIA. ANCHOR BOLTS @ 48" O.C. 2 x 10 WOOD FLOOR RIM JOIST (2) 2x10 FLUSH FRAMED HEADER FOR CRAWLSPACE ACCESS DOOR - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION BUILT-UP GIRDER - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. CRAWLSPACE FLUSH MOUNTED, INSULATED ACCESS PANEL DOOR. REFER TO FLOOR PLAN AND DOOR SCHEDULE FOR ADDITIONAL INFO. 2X P.T. WOOD SLEEPERS @ 16" O.C. 5 1/2" R21 KRAFT FACED F.G. INSUL. 6"9"EXISTING CMU FOUNDATION WALLS TO REMAIN. REPAIR WALL AS REQUIRED AND GROUT SOLID, TYP. OF (4) - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. VINYL "CLAPBOARD" SIDING - REFER TO EXTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION. 3-1/2" DIA. LALLY COLUMN ON REINF. CONC. FOOTING - REFER TO FOUNDATION PLAN FOR ADDITIONAL INFORMATION. 2X10 WOOD JOISTS @ 16" O.C. - REF. TO FRAMING PLAN FOR ADDTL. INFO. 9 1/2" R30 KRAFT FACED F.G. INSUL. INFILL DEMO FLOOR JOIST VOID W/ 2X WOOD JOIST & 1/2" PLYWOOD TO CREATE CONT. FLUSH WALL SURFACE. PREP WALL TO RECEIVE NEW WALL FINISH BUILT-UP GIRDER - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. 3/4" T&G PLYWOOD SHEATHING, TYP. REF. TO FINISH PLAN FOR FLOOR FINISH 3/4" PROVIDE WOOD BLOCKING AS REQUIRED 1x OAK SILL TRIM BOARD W/ BULL NOSE. FINISH STAIN TBD. 1x OAK APRON TRIM BOARD. FINISH COLOR TBD. 0'-0" A.F.F. FIRST FINISH FLOOR JSP PMA #DATE REVISION Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-400 BUILDING SECTIONS & NOTES.dwgLast save: Oct 10, 2019 - 2:11pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 400 BUILDING SECTIONS AND DETAILS SCALE: 3 ENLARGED SECTION DETAIL 1 1/2" = 1'-0" SCALE: 4 ENLARGED SECTION DETAIL 1 1/2" = 1'-0" SCALE: 5 ENLARGED SECTION DETAIL 1 1/2" = 1'-0" STAIR 1UP SCALE: 1 ENLARGED FIRST FLOOR STAIR PLAN 1/2" = 1'-0" N7'-8 1/2"1 A402 12'-1"3'-4"4 TREADS @ 11"4'-4 1/4"LANDING13'-11 1/2" 4'-1 1/2" LANDING 3 A401 UP A4 A1 B1 1-1/2" DIA. WOOD HANDRAIL TO BE INSTALLED PER STATE AND LOCAL BUILDING CODE REQUIREMENTS. G.C. TO PROVIDE BLOCKING IN WALL AS REQUIRED - HANDRAIL TO RECEIVE A MIN. OF (2) COATS OF POLYURETHANE, TYP. STAIR TREADS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. STAIR LANDINGS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. OF BOTH LANDINGS ENTRY / EXIST VESTIBULE 100 HALL 104 SALES AREA 102 ACCESSIBLE RESTROOM 106 106 1 100 3 100 1 102 1 STR 1 5'-10" (7) TREADS @ 11" 4'-0" HOLD1'-1"4'-0"4'-1"2'-7 1/2"4'-0 1/2" 6'-11 1/2"6'-8" 14'-4"1'-5 1/2"4'-0" CLEAR MIN. 1'-0" TYP. 11" TYP. 1'-11" TYP. B1 B B B2 BB A4 A4 A4 A1 B2 4'-0"CLEAR MIN.CRAWLSPACE FLUSH MOUNTED, INSULATED ACCESS PANEL DOOR. REFER TO FLOOR PLAN & DOOR SCHED. FOR ADDTL. INFO. 2X4 EXTERIOR WALL - REFER TO PLANS AND SECTIONS FOR ADDITIONAL INFORMATION, TYP. 2X4 EXTERIOR WALL - REFER TO PLANS AND SECTIONS FOR ADDITIONAL INFORMATION, TYP. 2X4 EXTERIOR WALL - REFER TO PLANS AND SECTIONS FOR ADDITIONAL INFORMATION, TYP. DN DN 1'-0" TYP. SCALE: 2 ENLARGED SECOND FLOOR STAIR PLAN 1/2" = 1'-0" N STAIR 1 X X4'-0"CLEAR MIN.4'-0 1/2"4'-0"CLEAR MIN.A1204 1 1 A402 12'-0 1/2"4'-4 1/4"LANDING3'-4"(4) TREADS @ 11"4'-4 1/4"LANDINGX 9'-10 1/2" 4'-1 1/2" LANDING11"TYP.1'-11" TYP. 3 A401 6'-7 1/2" 2'-6" (3) TREADS @ 11" 4'-1 1/2" LANDING 201 1202 1 STORAGE CLOSET 201 CORRIDOR 200 BREAK ROOM 204 PACKAGING 202 DN 4'-0" CLEAR MIN. 5'-6" CLEAR A1 A1 A1 A1 A1 1-1/2" DIA. WOOD HANDRAIL TO BE INSTALLED PER STATE AND LOCAL BUILDING CODE REQUIREMENTS. G.C. TO PROVIDE BLOCKING IN WALL AS REQUIRED - HANDRAIL TO RECEIVE A MIN. OF (2) COATS OF POLYURETHANE, TYP. STAIR TREADS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. STAIR LANDINGS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. OF BOTH LANDINGS STAIR 106 4'-0" CLEAR MIN. 1-1/2" DIA. WOOD HANDRAIL TO BE INSTALLED PER STATE AND LOCAL BUILDING CODE REQUIREMENTS. G.C. TO PROVIDE BLOCKING IN WALL AS REQUIRED - HANDRAIL TO RECEIVE A MIN. OF (2) COATS OF POLYURETHANE, TYP. STAIR TREADS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. FRAME INTERIOR STAIR WITH (3) 2x12 STRINGERS. OUTSIDE STRINGERS TO BE DOUBLE. TOP OF STRINGERS TO BE JOIST HUNG, TYP. FRAME INTERIOR STAIR LANDINGS WITH 2x8 WOOD JOISTS AT 16" O.C.. OUTSIDE JOISTS TO BE DOUBLE, TYPICAL OF BOTH LANDINGS ± 4'-8"8R @ 7" (MAX.)± 2'-11"5R @ 7" (MAX.)± 2'-4"4R @ 7" (MAX.)9'-10"17R @ 7" (MAX.)0'-0" A.F.F. FIRST FINISH FLOOR ± 9'-10" A.F.F. SECOND FINISH FLOOR STAIR LANDINGS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. OF BOTH LANDINGS ± 7'-6 1/2" A.F.F. LANDING ± 4'-8" A.F.F. LANDING STR 1 203 1 BREAK ROOM 204 SALES AREA 102 102 1 4'-0" CLEAR MIN. 4'-4 1/4" LANDING 3'-4" (4) TREADS @ 11" 4'-4 1/4" LANDING 12'-0 1/2" 11" TYP.2'-10"TYP.STAIR NOSING TO HAVE 1" OVERHANG, TYP. STAIR RISERS TO 3/4" MAPLE BOARDS PAINTED WHITE. WALL BASE. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION INFILL DEMO FLOOR JOIST VOID W/ 2X WOOD JOIST & 1/2" PLYWOOD TO CREATE CONT. FLUSH WALL SURFACE. PREP WALL TO RECEIVE NEW WALL FINISH 2X8 P.T. SILL ON SILL SEALER AT NEW EXTERIOR WALL CONSTRUCTION 1/2" DIA. ANCHOR BOLTS @ 48" O.C. AT NEW EXTERIOR WALL CONSTRUCTION (2) 1-3/4" x 11-1/4" LVL BEAMS - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. 2X4 @ 16" O.C. NON-BEARING PARTITION - REF. PARTITION TYPES, TYP. SCALE: 3 ENLARGED STAIR SECTION 3/4" = 1'-0" NOTE: SEE SECTION 2/A-400 FOR TYPICAL NOTES JSP PMA #DATE REVISION Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-401 ENLARGED STAIR PLAN, SECTIONS, & DETAILS.dwgLast save: Oct 10, 2019 - 3:16pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 401 ENLARGED STAIR PLANS AND SECTION ± 2'-4"4R @ 7" (MAX.)9'-10"17R @ 7" (MAX.)0'-0" A.F.F. FIRST FINISH FLOOR ± 9'-10" A.F.F. SECOND FINISH FLOOR ± 7'-6 1/2" A.F.F. LANDING ± 7'-6 1/2"ACCESSIBLE RESTROOM 106 201 1 202 1 STAIR 106 WALL BASE. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION INFILL DEMO FLOOR JOIST VOID W/ 2X WOOD JOIST & 1/2" PLYWOOD TO CREATE CONT. FLUSH WALL SURFACE. PREP WALL TO RECEIVE NEW WALL FINISH STAIR LANDINGS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. OF BOTH LANDINGS 4'-0" CLEAR MIN. 2'-6" (3) TREADS @ 11" 4'-4 1/4" LANDING 1-1/2" DIA. WOOD HANDRAIL TO BE INSTALLED PER STATE AND LOCAL BUILDING CODE REQUIREMENTS. G.C. TO PROVIDE BLOCKING IN WALL AS REQUIRED - HANDRAIL TO RECEIVE A MIN. OF (2) COATS OF POLYURETHANE, TYP. 11" TYP.2'-10"TYP.STAIR NOSING TO HAVE 1" OVERHANG, TYP. STAIR RISERS TO 3/4" MAPLE BOARDS PAINTED WHITE. STAIR TREADS TO BE 3/4" PLYWOOD. REFER TO FINISH SCHEDULE FOR STAIR FINISH, TYP. FRAME INTERIOR STAIR WITH (3) 2x12 STRINGERS. OUTSIDE STRINGERS TO BE DOUBLE. TOP OF STRINGERS TO BE JOIST HUNG, TYP. FRAME INTERIOR STAIR LANDINGS WITH 2x8 WOOD JOISTS AT 16" O.C.. OUTSIDE JOISTS TO BE DOUBLE, TYPICAL OF BOTH LANDINGS (2) 1-3/4" x 9-1/4" LVL BEAMS BELOW BEARING WALL ABOVE - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. (2) 2X12 FLUSH FRAMED HEADER - REFER TO FRAMING PLAN FOR ADDITIONAL INFORMATION. 2X4 @ 12" O.C. WOOD STUD BEARING PARTITION - REF. PARTITION TYPES, TYP. SCALE: 1 ENLARGED STAIR SECTION 3/4" = 1'-0" NOTE: SEE SECTION 1/A-400 FOR TYPICAL NOTES JSP PMA #DATE REVISION Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-401 ENLARGED STAIR PLAN, SECTIONS, & DETAILS.dwgLast save: Oct 10, 2019 - 2:11pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 402 ENLARGED STAIR SECTION AND DETAILS PAINTED ACCENT COLOR ELEVATION AELEVATION BELEVATION CELEVATION D ELEVATION AELEVATION BELEVATION CELEVATION D +/- 7'-9" U.S. GWB CLNG 8'-0" U.S. GWB CLNG B-4B-4 3'-0"3'-0"2'-0"B-4B-4B-4 B-4 B-4 1'-0" PAINTED PAINTED PAINTED PAINTED PAINTED PAINTED 40" MAX A.F.F.TOWEL DISPENSER6"11" 8"27" MIN.MAXMIN. MIN. T-2 CERAMIC TILE FULL HEIGHT2'-10"4"MAX17"107 1 205 1 T-1T-1 SS-1 T-2 T-4 SS-1 T-3 T-5 T-5 T-6 T-6 T-7 T-8 T-12 T-13 T-9 T-4 PL-4 PL-4 T-14 SS-1 PL-4 T-13 T-11 2'-10"4"2'-112" SCHLUTER EDGE AS SPECIFIED, TYP. METAL FRAME, PTD. AS SPECIFIED, TYP. METAL FRAME, PTD. AS SPECIFIED, TYP. EXISTING WOOD TRIM TO BE P&R, PAINTED L-6 AS SPECIFIED, TYP. T-7 L-6 AS SPECIFIED, TYP. T-12 T-4 # B-38032 TRIMLINE SERIES # B-290 2436 ADA WALL MOUNTED LAVATORY T-2 T-10 KOHLER K-2035-1-0 PINOIR KOHLER K-3810-0 SANTA ROSA ALL ACCESSORIES ARE SPECIFIED AS MANUFACTURED BY BOBRICK UNLESS NOTED OTHERWISE. 24"x36" WELDED FRAME MIRROR SEMI RECESSED PAPER TOWEL DISPENSER / WASTE RECEPTACLE NOTES: ·REFER TO MEP & ENG. DWGS FOR FINAL SPECIFICATIONS. ·G.C. TO PROVIDE RECESSED SOLID BLOCKING FOR ALL ACCESSORIES, INCLUDING GRAB BARS AND SINK. ·ALL PLUMBING FIXTURES TO COMPLY WITH STATE CODE # B-6806.99x42 ; PEENEDT-1 42" GRAB BAR RESTROOM ACCESSORY SCHEDULE MFG. NO.ITEMNO. T-3 # B-76867SURFACE-MOUNTED DOUBLE ROLL TOILET TISSUE DISPENSER T-5 HEAVY-DUTY CLOTHES HOOK W/ EXPOSED MOUNTING # B-211 MOUNT @ 54" MAX. A.F.F. T-8 UNDER MOUNT SINK T-11 KOHLER K-2355-0 ARCHER RECESSED SANITARY NAPKIN DISPOSAL # B-35303 TRIMLINE SERIES T-6 AUTOMATIC SOAP DISPENSERT-7 NOT USED # B-76857SURFACE-MOUNTED SINGLE ROLL TOILET TISSUE DISPENSER # B-2013 T-9 SURFACE -MOUNTED PAPER TOWEL DISPENSER # B-5262 T-13 FLOOR MOUNTED TOILET display ACCESSIBLE RESTROOM 107 2 A-500 B A D C 1'-10"1'-6"BATH 205 4 A-500 B A D C 2'-112"3'-0"30"X48" CLEAR SPACE REQ'D FORWARD REACH SIDE REACH FIRE ALARM, THERMOSTAT ROOM IDENTIFICATION DOOR LEVERS OUTLETS1'-6" 5'-0" 4'-6" 3'-0" NOTES: 1. DIAGRAMS SHOWN ON THIS SHEET ARE NOT TO SCALE. 2. ALL DIMENSIONS LABELED "HOLD" ARE MANDATED BY CODE AND MUST BE MAINTAINED. 3. REFER TO CMR 521 SECTION 6.5 & 6.6 FOR ALL MOUNTING HEIGHTS. 4. FORWARD REACH IS TO BE 15" TO 48", SIDE REACH IS 9" TO 54" WITHOUT OBSTRUCTION. REFER TO AAB 521 CMR SECTIONS 6.5-6.6. TYPICAL MOUNTING HEIGHTS 9"MIN.15"MIN.LEVER HANDLE EXIT STAIRS COMPLIANT TACTILE SIGNAGE 5'-0"1. DOOR OR WALL MOUNTED SIGNAGE 2. ALL SIGNAGE SHALL CONFORM WITH M.A.A.B. GUIDELINES 48" MAX.54" MAX.ADULT SPECIFIC REQUIREMENTS: AAB (521 CMR) ACCESSORY AND FIXTURE MOUNTING HEIGHTSSIGNAGE ROOM NAME CL 48" 30"X48" CLEAR SPACE REQ'D LAVATORY NOTES: 1.PROVIDE A CLEAR SPACE 30"x48" MIN. IN FRONT OF THE LAVATORY. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACE UNDER LAVATORY. 2.HOT WATER SUPPLY AND DRAIN PIPING UNDER LAVATORIES SHALL BE RECESSED, INSULATED, OR GUARDED TO PREVENT CONTACT. 3.NO SHARP OR ABRASIVE ELEMENTS ARE ALLOWED UNDER LAVATORIES. 4.FAUCET CONTROLS AND OPERATING MECHANISMS ARE REQUIRED TO BE OPERABLE WITH ONE HAND AND CANNOT REQUIRE GRASPING, PINCHING, OR TWISTING OF WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS IS NOT TO EXCEED 5 LBS. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN. 5.SELF CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. 17"-25"9"MIN.6" MAX. 11" MIN.27" MIN.KNEE CLEARANCE8" MIN.29" MIN.34" MAX.40" MAXB.O. REFLECTINGSURFACE30"X48" CLR FLOOR SPACE MAX 6 1/2" SINK DEPTH 19" MAX. TOILET ACCESSORY NOTES: 1.THE TOP OF ANY SHELF AND OR BOTTOM OF ANY MIRROR THAT IS PROVIDED ABOVE A SINK SHALL BE SET WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN 40 INCHES ABOVE THE FINISH FLOOR. 2.TOWEL DISPENSERS, DRYING DEVICES, OR OTHER TYPES OF DEVICES AND DISPENSERS SHALL HAVE AT LEAST ONE OF EACH DEVICE MOUNTED WITHIN THE ZONE OF REACH. AT LEAST ONE OF EACH DEVICES SHALL BE LOCATED WITHIN REACH OF A PERSON USING THE ACCESSIBLE SINK. 3.IF CONTROLS, RECEPTACLES, OR OTHER EQUIPMENT IS PROVIDED, THEN AT LEAST ONE OF EACH SHALL BE ON AN ACCESSIBLE ROUTE AND WITHIN THE REACH RANGES SPECIFIED IN 521 CMR 6.00. SEAT COVER DISPENSER TOWEL AND TRASH RECEPTACLES HAND DRYER PRODUCT DISPENSER MIRROR 40" MAX.Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-500 ENLARGED PLANS & ELEVATIONS.dwgLast save: Oct 10, 2019 - 2:11pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 500 ENLARGED PLANS & ELEVATIONS JSP AMC SCALE: 1 ACCESSIBLE RESTROOM 107 1/2"=1'-0" ENLARGED PLAN- SCALE: 2 RESTROOM 107 1/2"=1'-0" ENLARGED PLAN- SCALE: 3 BATH 205 1/2"=1'-0" ENLARGED PLAN- SCALE: 4 BATH 205 1/2"=1'-0" ENLARGED PLAN- REMARKS A.EXTERIOR DOOR ASSEMBLY TO HAVE AN OVERALL U-FACTOR OF 0.77. GLAZING TO BE CLEAR LOW-E, U-VALUE OF 0.38, AND SHGC OF 0.40. G.C. TO VERIFY THAT EXTERIOR DOORS MEET 2015 ENERGY REQUIREMENTS. B.G.C. TO VERIFY ROUGH OPENINGS AND JAMB DEPTHS AT ALL DOORS PRIOR TO ORDERING DOORS AND FRAMES. C.G.C. IS SOLELY RESPONSIBLE FOR VERIFYING QUANTITY OF DOORS AND FRAMES WITH THE FLOOR PLANS PRIOR TO ORDERING. D.SEE FLOOR PLAN FOR REQUIRED DOOR SWING. E.ALL METAL DOOR FRAMES ON FIRST FLOOR TO RECEIVE WOOD CASING, TYPICAL. REFER TO FINISH SPECIFICATIONS FOR ADDITIONAL INFORMATION. F.ALL ROOMS WITH SUPPLY AIR AND NO RETURN OR EXHAUST TO HAVE 1" UNDERCUT UNLESS NOTED OTHERWISE. DOOR SCHEDULE DOOR TAG ROOM NAME DOOR SIZE WIDTH HGT THK MATL GLASS ELEV MATL ELEV JAMB DEPTH FRAME HARDWARE SET NO. KEY SIDE RM. NO. COMMENTS 1st FLOOREXTERIOR SALES AREA #102 3 - SECURITY OFFICE #101 --1 -3 3'-0"7'-0"HALL #104 3'-0"7'-0" STAIR 1 3'-0"7'-0"1 3/4"WD -3 -MTL 3'-0"7'-0"1 3/4"WD -6MTL (2) 3'-0"7'-0"1 3/4"WD 5 V.I.F.MTL SALES AREA #102 ACCESS. RESTROOM #106 -63'-0"7'-0"1 3/4"WD 1"6MTL 1 3/4"WD -8 -6MTL 1 3/4"WD -4 -6MTL BATH #205 COUNTING ROOM #206 3'-0"6'-8"1 3/4"-WD MTL VAULT #207 3'-0"6'-8"1 3/4"-MTL MTL 1" 2'-0"6'-8"1 3/4"WD -MTLSTORAGE CLOSET #201 6 3'-0"6'-8"1 3/4"WD -6MTLOFFICE #203 3'-6"6'-8"C.O.--7MTL EXIST.EXIST.1 3/4"MTL 1"6MTL BREAK ROOM #204 BREAK ROOM #204 TO FROM 100 1 ENTRY / EXIST VESTIBULE #100 ENTRY / EXIST VESTIBULE #100 HALL #104 JANITOR CLOSET #105 ENTRY / EXIST VESTIBULE #100 HALL #103A HALL #104 100 2 101 1 103A 1 105 1 106 1 STR 1 2nd FLOOR201 1 203 1 204 1 204 2 205 1 206 1 207 1 3'-0"6'-8"1 3/4"WD -6MTLCORRIDOR #200 CORRIDOR #200 COUNTING ROOM #206 CORRIDOR #200 CORRIDOR #200 CORRIDOR #200 EXTERIOR 4 4 3 4 4 1 4 3/4" 4 3/4" 4 4 4 4 - 2 4 4 3/4" 4 3/4" 4 3/4" 6 6 6 4 3/4" 4 3/4" 4 3/4" EXIST 4 3/4" 4 3/4" V.I.F. 7 5 - 2 4 3 3 - - - - - - - -- -- EXISTING DOOR AND FRAME TO REMAIN EXISTING DOOR AND FRAME TO REMAIN EXIST. ELEC. ROOM #103 HALL #103A103A 2 EXIST.EXIST.1 3/4"MTL - -- - - - - - PROVIDE 1" UNDERCUT - PROVIDE 1" UNDERCUT - CASED FRAMED OPENING - - - - 6MTL4 EXIST. 103A 3 103A 4 EXIST. ADJACENT TENANT EXIST. ADJACENT TENANT HALL #103A HALL #103A EXISTING DOOR AND FRAME TO REMAIN TOP OF FIN. FLOOR ENTRY VESTIBULE #100 EXTERIOR DOOR1 EXIST. TOP OF FIN. FLOOR T 1" CLEAR LOW-E, TEMPERED DOUBLE PANE INSULATED GLASS EXIST.BREAK ROOM #204 EXTERIOR DOOR23'-0"2'-0" 3'-0" TOP OF FIN. FLOOR T 1/4" CLEAR TEMPERED GLASS W/ 3M PRIVACY FILM 7'-0"INTERIOR DOOR34'-6"2'-0" TOP OF FIN. FLOORVARIESSEE DOOR SCHEDULEVARIES SEE DOOR SCHEDULE REFER TO PLAN FOR CORRECT SWING ORIENTATION INTERIOR DOOR4 REFER TO PLAN FOR CORRECT SWING ORIENTATION EXTERIOR DOOR FRAME5 TOP OF FIN. FLOOR 3'-0" 2"2"7'-2"2"7'-0"INTERIOR DOOR FRAME6 TOP OF FIN. FLOOR VARIES SEE DOOR SCHEDULE 2"2"VARIESSEE DOOR SCHEDULE2"VARIESSEE DOOR SCHEDULE6'-6" NOTE: FACTORY PRIMED AND FIELD PAINTED 18 GA. WELDED METAL FRAME NOTE: FACTORY PRIMED AND FIELD PAINTED 18 GA. WELDED METAL FRAME SCALE: A DOOR TYPES / FRAMES 1/4" = 1'-0" HARDWARE NOTES: 1.ALL DOOR HARDWARE TO BE LEVER TYPE TO MEET ADA REQUIREMENTS. 2.USE WELDED DOOR BUCKS ONLY. 3.DO NOT USE KNOCK DOWN TYPE. 4.DOOR SCOPE TO BE INSTALLED AT 54" A.F.F. 5.DOOR LATCHES AND LOCKSETS SHALL BE BELOW 48", TYP. 6.ALL DOORS TO BE FITTED WITH DOOR SILENCERS. NOTE: IF DOUBLE DOORS HAVE MULTIPLE LOCKS, ALL HOUSINGS EXCEPT FOR THE MAIN SHALL BE BLANK. G.C. TO CONFIRM THAT EXTERIOR DOORS WILL ACCOMMODATE SECURITY VENDOR PROVIDED CORES. 2'-7" 2"2"2'-3"7'-2"2"6'-4"8"TOP OF FIN. FLOORTOP OF FIN. FLOOR7'-2"2"3'-8"3'-2"A.F.F.2"5'-6" 2" 2" 2"2'-0"3'-0" SLIDING TOP OF FIN. FLOOR EXIST. R.O. G.C. TO V.I.F.EXISTINGEXISTING R.O.G.C. TO V.I.F.A EXTERIOR WINDOW C INTERIOR WINDOW D INTERIOR WINDOW 1" CLEAR LOW-E, TEMPERED DOUBLE PANE INSULATED GLASS 1/4" CLEAR TEMPERED GLASS 1/4" CLEAR TEMPERED GLASS. SCALE: B WINDOW TYPES / FRAMES 1/4" = 1'-0" 1.ALL EXTERIOR AND INTERIOR DOORS SHALL BE BY MARSHFIELD DOOR SYSTEMS, SOLID CORE OR APPROVED EQUAL. VENEER AND FACTORY FINISH STAIN TO BE DETERMINED. G.C. TO SUBMIT FINISH SAMPLES & SHOP DRAWINGS TO ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO ORDERING. 2.MORTISE STEEL DOOR FRAMES AND PROVIDE W/ REINFORCEMENT PLATES FOR HARDWARE SECURITY WELD PLATES IN PLACE AT FACTORY & TAP FOR SCREWS, WELD IN FOUR PLACES. PROVIDE STRIKE PLATE REINFORCING. 3.ALL DOOR FRAMES SHALL HAVE SILENCERS 4.ALL DOOR HARDWARE SHALL BE A.D.A. COMPLIANT. 5.ALL INTERIOR DOORS SHALL BE 1-3/4" FLUSH SOLID CORE U.N.O. 6.DOORS WITH CLOSER SHALL HAVE BALL BEARING HINGES. CLOSERS SHALL MEET OR EXCEED ACCESSIBILITY REQUIREMENTS, TO BE ADJUSTED AS FOLLOWS: MAXIMUM FORCE TO OPEN SHALL BE 8.5 LBS FOR EXTERIOR DOORS AND 5 LBS FOR INTERIOR DOORS. A MOMENTARY AUXILIARY FORCE EXCEEDING THE MAXIMUM IS APPROVED IN ORDER TO OVERCOME THE INERTIA OF THE DOOR. SWEEP PERIOD OF CLOSERS SHALL BE AT LEAST 3 SECONDS FROM 90 DEGREES TO APPROXIMATELY 12 DEGREES. 7.DOOR FLOOR STOP SHALL BE OMNIA 7000, BRASS. COORD. FINAL PLACEMENT W/ ARCH. DOOR WALL STOP SHALL BE "IVES" WS401CCV - 1/2 CONCAVE WALL BUMPER/STOP 8.CONTRACTOR SHALL CONFIRM DOOR FUNCTION AND KEYING OF LOCKSETS AND DEAD BOLTS WITH OWNER AND SECURITY CONSULTANT PRIOR TO PURCHASING HARDWARE. 9.COORD. SECURITY REQUIREMENTS W/ RESPECT TO DOOR ELECTRONIC HARDWARE WITH OWNER AND SECURITY CONSULTANT PRIOR TO PURCHASING HARDWARE. 10.PROVIDE ACCESSIBLE SIGNAGE AT RESTROOM AND EXIT DOORS 11.G.C. SHALL PROVIDE ENGINEERING APPROVAL FOR EXTERIOR DOORS AT TIME OF SUBMITTAL TO BUILDING DEPARTMENT. 12.ALL THRESHOLDS SHALL HAVE NO STEP GREATER THAN 1/2" PER A.D.A. REQUIREMENTS. 14.HARDWARE FINISH THROUGHOUT DISPENSARY TO BE BRUSHED BRASS. 15.HINGES, BUTTS & PIVOTS: FULL MORTISE, BALL BEARING TYPE IVES O.A.E. 3 HINGES PER DOOR, STEEL PINS ON STEEL HINGES, STAINLESS STEEL PINS ON NON-FERROUS HINGES. 16.SUBMIT A FINAL HARDWARE SCHEDULE FOR ARCHITECT'S & SECURITY CONSULTANT'S REVIEW. COORDINATE HARDWARE WITH DOORS, FRAMES, AND RELATED WORK TO ENSURE PROPER SIZE, HAND, FUNCTION, AND FINISH OF HARDWARE. DOORS AND HARDWARE NOTES: ENTRY / EXIST VESTIBULE #100 -6A3'-0"7'-0"1 3/4"WD 1"6MTLSALES AREA #102100 3 3 4 3/4"- DOOR CONTACT - COORDINATE WITH SECURITY VENDOR CRAWLSPACE -8B3'-0" (V.I.F.) 3'-0" (V.I.F.)2"GALV. MTL --GALV. MTLSALES AREA #102102 1 -(V.I.F.) COORDINATE SIZE WITH MECHANICAL SUBCONTRACTOR. VERIFY TYPE AND SECURITY LOCKSET W/ OWNER PRIOR TO ORDERING. DOOR TO BE INSULATED 1'-10" (V.I.F.) 3'-0" (V.I.F.)2"MTL -MTLATTIC200 1 CORRIDOR #200 --(V.I.F.)8B - 3'-0"6'-8"1 3/4"WD -6MTLPACKAGING #202202 1 CORRIDOR #200 4 4 3/4"3 -- T7'-0"4'-6"3'-0" 2'-0" 1" CLEAR LOW-E, TEMPERED DOUBLE PANE INSULATED GLASS CASED OPENING7 TOP OF FIN. FLOOR 3'-10" 2"2"6'-10"2"6'-8"NOTE: FACTORY PRIMED AND FIELD PAINTED 18 GA. WELDED METAL FRAME 3'-6"1- G.C. TO VERIFY ROUGH OPENINGS WITH MANUFACTURER PRIOR TO CONSTRUCTION. 2- EXTERIOR WINDOWS TO BE FIXED HARVEY TRIBUTE COMMERCIAL WINDOWS SERIES OR APPROVED EQUAL, WITH 5/8" CONTOUR GRID BETWEEN GLASS, AND WHITE CLAD EXTERIOR AND INTERIOR SURFACES. G.C TO VERIFY ROUGH OPENINGS PRIOR TO FRAMING. 3- EXTERIOR WINDOWS TO HAVE CLEAR LOW-E, ARGON GLAZING GLAZING, U-VALUE OF 0.25, AND SHGC OF 0.40. G.C. TO VERIFY THAT EXTERIOR WINDOWS MEET IECC 2015 ENERGY REQUIREMENTS, INCLUDING 117 MPH WIND ZONE DESIGN REQUIREMENT. 4- INTERIOR WINDOWS TO BE FIXED WINDOWS WITH METAL FRAME UNLESS OTHERWISE NOTED. G.C. TO VERIFY MANUFACTURER, FUNCTION, STYLE AND FINISH WITH OWNER AND ARCHITECT PRIOR TO SUBMITTING SHOP DRAWINGS AND HARDWARE SCHEDULE. 5- G.C. TO REFER TO FINISH SPECIFICATIONS FOR PRIVACY FILM LOCATIONS AND SPECIFICATION. 6- ALL WINDOW FRAMES TO RECEIVE WOOD CASING, TYPICAL. REFER TO FINISH SPEC. FOR ADDITIONAL INFORMATION. COORDINATE SIZE WITH MECHANICAL SUBCONTRACTOR. VERIFY TYPE AND SECURITY LOCKSET W/ OWNER PRIOR TO ORDERING. DOOR TO BE INSULATED TOP OF FIN. FLOOR 3'-0"MATCH EXTERIORDOOR HEAD HEIGHT4'-0"B EXTERIOR WINDOW 1" CLEAR LOW-E, TEMPERED DOUBLE PANE INSULATED GLASS SECURITY OFFICE #101 -3A3'-0"7'-0"1 3/4"WD -6MTLI.T.CLOSET #101A101A 1 4 4 3/4"PROVIDE 1" UNDERCUT 3'-0"6'-8"1 3/4"WD -MTLCORRIDOR #200200A 1 JANITOR CLOSET #200A 4 6 4 3/4"8A -PROVIDE 1" UNDERCUT EXIST.V.I.F.± 3'-0"V.I.F.3'-0" 2" T T TT T T T 3'-0" FIXED 2'-0" STOREROOM - SECURE 3 HINGES 1 STOREROOM LOCKSET1 1 FLOOR STOP 1 DUST PROOF STRIKE 3 DOOR SILENCERS HARDWARE SET # QTY. PER LEAF ITEM REMARKS 1 EXTERIOR - MAIN ENTRANCE 3 HINGES 1 EXIT DEVICE 1 WIRELESS LOCK COORD SPEC & DOOR CONTACT REQ'S W/ SECURITY VENDOR 1 ELECTRIC STRIKE COORD REQ'S W/ SECURITY VENDOR 1 RIM CYLINDER 1 DOOR CLOSER INSTALL ON PUSH SIDE OF DOOR 1 GASKET 1 DOOR SWEEP/DRIP 1 SADDLE THRESHOLD 2 EXTERIOR - BREAK ROOM 3 HINGES 1 STOREROOM LOCKSET 1 FLUSH BOLT 1 RIM CYLINDER 1 DOOR CLOSER INSTALL ON PULL SIDE OF DOOR 1 GASKET 1 DOOR SWEEP/DRIP 1 SADDLE THRESHOLD 1 DOOR CONTACT COORD W/ SECURITY VENDOR HARDWARE SCHEDULE 1 FLOOR STOP STOREROOM - SECURE 3 HINGES 1 FLUSH BOLT 1 STOREROOM LOCKSET 1 DOOR CLOSER INSTALL ON PULL SIDE OF DOOR 1 KICKPLATE INSTALL ON PUSH SIDE OF DOOR 1 FLOOR STOP 1 DUST PROOF STRIKE 3 DOOR SILENCERS 3 FLUSH BOLT 3A PRIVACY 3 HINGES 1 PRIVACY SET 1 DOOR CLOSER 1 KICKPLATE INSTALL ON PUSH SIDE OF DOOR 1 FLOOR STOP 3 DOOR SILENCERS 4 INSTALL ON PULL SIDE OF DOOR OFFICE 3 HINGES 1 LOCKSET 1 FLOOR STOP 1 COAT & HAT HOOK 3 DOOR SILENCERS 5 6 VESTIBULE (ENTRY) - SECURE 3 HINGES 1 ELECTRIFIED STOREROOM LOCKSET 1 FLUSH BOLT 1 DOOR CLOSER INSTALL ON PUSH SIDE OF DOOR 1 KICKPLATE INSTALL ON PUSH SIDE OF DOOR 1 FLOOR STOP 1 POWER TRANSFER COORD W/ SECURITY VENDOR 3 DOOR SILENCERS 6A VESTIBULE (EXIT) - SECURE 3 HINGES 1 ELECTRIFIED STOREROOM LOCKSET 1 FLUSH BOLT 1 DOOR CLOSER INSTALL ON PUSH SIDE OF DOOR 1 KICKPLATE INSTALL ON PUSH SIDE OF DOOR 1 FLOOR STOP 1 POWER TRANSFER COORD W/ SECURITY VENDOR 3 DOOR SILENCERS 1 EXIT DEVICE PASSAGE 3 HINGES 1 PASSAGE SET 1 FLOOR STOP 1 KICKPLATE 3 DOOR SILENCERS 7 INSTALL ON PUSH SIDE OF DOOR 3 HINGES 1 STOREROOM LOCKSET 1 1 FLOOR STOP1 3 DOOR SILENCERS KICKPLATE INSTALL ON PUSH SIDE OF DOOR DOOR CLOSER INSTALL ON PUSH SIDE OF DOOR UTILITY8 3 HINGES 1 STOREROOM LOCKSET FLOOR STOP1 3 DOOR SILENCERS UTILITY8A 3 HINGES 1 STOREROOM LOCKSET 1 1 GASKET1 PUSH/PULL HANDLE INSTALL ON PUSH SIDE OF DOOR FLUSH PULL HANDLE INSTALL ON PULL SIDE OF DOOR UTILITY8B JSP PMA Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_A-700 DOOR, WINDOW, & HARDWARE SCHEDULES.dwgLast save: Oct 10, 2019 - 3:24pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID A 700 DOOR, WINDOW, & HARDWARE SCHEDULES ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) 1 2 3 4-ADA ONLINE PICK-UP? basement access millwork (bud bar?) displaydisplaydisplay SCALE: 1 FIRST FLOOR FINISH PLAN 1/4" = 1'-0" ENTRY VESTIBULE 100 SALES AREA 102 EXISTING STORAGE SHED (N.I.C.) HALL 104 STAIR 1MAT WD-1 WD-1 LT-1 LT-1 POS STATIONS 102A WD-1 LT-1 WD-4T-1 CPT-1ACCENTPAINTT-2WP ACCENT PAINT T-2 SCHLUTER JOLLYWD-2MTLT-2WD-4WD-2WPACCENT PAINT ACCESSIBLE RESTROOM 106 EXISTING ELEC. RM 103 HALL 103A JANITOR CLOSET 105 6'-0" WALL PANELWCWC SDT CLOSET 101A 31'-10"17'-412" 5'-0" 21'-1112"5'-0"7'-912"9'-5"912"FRP 4'high SECURITY OFFICE 101 WD-1 WC attic access countertop wall shelving wall shelving SCALE: 2 SECOND FLOOR FINISH PLAN 1/4" = 1'-0" STAIR 1 OFFICE 203 CORRIDOR 200 BATH 205 COUNTING ROOM 206 EXISTING OUTDOOR DECK CPT-1 LT-1 T-1 CPT-1 CPT-1 CPT-1 PACKAGING 202 CPT-1 STOR. CLO. 201 CPT-1ACCENT PAINTACCENTPAINTVAULT 207 ACCENT PAINT TWO COLOR PATTERN T.B.D.7'-1012"14'-0"2'-1"1'-0"2'-112"3'-0"5'-614"1'-018"JAN. CLO. 200A LT-1 BREAK ROOM 204 LT-1 LT-2 FRP 4'high WT WT WT WTWTWT WTWTFINISH SCHEDULE- FIRST FLOOR WALLS: REFER TO 1/I-100 & I-300 ROOM FLOOR BASE WALLS CEILING CEILING HEIGHT REMARKSNORTH: UP SOUTH: DOWN EAST: RIGHT WEST: LEFT 100 ENTRY VESTIBULE MAT-1 B-3 P-WC P-WC WD-1 8'-9"- 101 SECURITY OFFICE WD-1 B-3 P-P-P-P-ACCE NT GWB 8'-0"- 101A IT CLOSET SDT-1 B-1 P-P-P-P-ACP 8'-0"- 102 SALES AREA WD-1 B-3 ----GWB/ WD-1 7'-6" - 8'-9"REFER TO FINISH PLAN & I-300, 301, 302 FOR WALL FINISHES 102A POS STATIONS WD-1 B-3 ----GWB/ WD-1 7'-6"REFER TO FINISH PLAN & I-300, 301, 302 FOR WALL FINISHES 103 EXISTING ELECTRICAL ROOM LT-1 B-1 P-P-P-P-GWB 7-6"- 103A HALL 103A LT-1 B-1 P-P-P-P-ACP 7-6"- 104 HALL WD-1 B-3 P-ACCE NT P-P-P-GWB 8'-0"- 105 JANITOR CLOSET LT-1 B-1 P-/ FRP P-P-P-/ FRP ACP 8'-0"- 106 ACCESSIBLE RESTROOM T-1 B-4 P-P-P-T-2 GWB 8'-0"T-2 WALL TILE FULL HEIGHT FINISH SCHEDULE- SECOND FLOOR WALLS: REFER TO 1/I-100 & I-300 ROOM FLOOR BASE WALLS CEILING CEILING HEIGHT REMARKSNORTH: UP SOUTH: DOWN EAST: RIGHT WEST: LEFT 200 CORRIDOR CPT-1 B-2 P-P-P-P-GWB 7'-9+/-"- 200A JANITOR CLOSET LT-1 B-1 P-/ FRP P-P-/ FRP P-ACP 7'-9+/-"- 201 STORAGE CLOSET CPT-1 B-2 P-P-P-P-ACP 7'-9+/-"- 202 PACKAGING CPT-1 B-2 P-P-P-P-GWB 7'-9+/-"- 203 OFFICE CPT-1 B-2 P-P-P-P-GWB 7'-9+/-"- 204 BATH T-1 B-4 P-P-P-P-GWB 7'-9+/-"- 205 BREAK ROOM LT-1/LT-2 B-1 P-P-P-P-GWB 7'-9+/-"- 206 COUNTING ROOM CPT-1 B-2 P-P-P-P-GWB 7'-9+/-"- 207 VAULT LT-1 B-1 P-P-P-P-GWB 7'-9+/-"- STAIR 1 STAIR CPT-1 B-2 P-P-P-P-GWB 7'-9+/-" FINISH PLAN LEGEND FINISH TAG. SEE I-101 FOR FINISH SPECIFICATIONS INDICATES FLOORING TRANSITION KEY FLOORING PATTERN DIRECTION P-1 1 D FINISH NOTES 1.REFER TO G-200 & G-201 GENERAL SPECIFICATIONS 2.SPECIFIED FINISHES ARE SUBJECT TO CHANGE PENDING OWNER FINAL REVIEW AND APPROVAL. 3.SHOULD THE INSTALLER FIND ANY DISCREPANCIES, OMISSIONS, AMBIGUITIES OR CONFLICTS ON THE PLANS, HE SHOULD BRING THE ITEM(S) TO THE ARCHITECT'S ATTENTION FOR DIRECTION BEFORE PROCEEDING WITH ANY WORK IN QUESTION AND/OR ORDERING MATERIALS. 4.LEVEL ALL FLOORS TO 1/8" IN 10'-0" FLASH-PATCH WITH LEVELASTIC @ TRANSITION 5.ALL GWB SOFFITS & GWB CEILINGS TO RECEIVE NOTED PAINT @ UNDERSIDE, FLAT FINISH 6.REFER TO A-201 & A-202 FOR ACOUSTICAL CEILING PANEL & SUSPENSION SYSTEM SPECIFICATIONS. 7.G.C. TO CAULK ALL EXPANSION JOINTS IN NEW WORK AREAS USING FOAM BACKER RODS, SPRAY EXPANSION FOAM, & CLEAR CAULKING. EXPANSION JOINTS TO BE CLEARED OF DEBRIS PRIOR TO CAULKING. 8.TILE SUB-CONTRACTOR SHALL PROVIDE (FURNISH AND INSTALL) FLOOR , WALL TILE & METAL TRIM AS SPECIFIED. 9.UPON RECEIPT FROM THE MANUFACTURER, THE INSTALLER SHALL INSPECT ALL MATERIALS FOR DEFECTS, SHIPPING DAMAGE, CORRECT COLOR AND PATTERN. DAMAGED OR INCORRECT MATERIALS SHALL BE RETURNED TO THE MANUFACTURER FOR IMMEDIATE REPLACEMENT TO PREVENT DELAYS IN THE COMPLETION OF THE WORK. THE INSTALLER SHALL INFORM THE ARCHITECT OF ANY DEFECTIVE MATERIALS AND COORDINATE WITH THE MANUFACTURER FOR AN ACCURATE SHIPPING DATE FOR THE REPLACEMENT MATERIALS. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF LOCATION CHANGES IN DYE LOTS OR COLOR SHIFTS. 10. SHOP DRAWINGS, PAINT DRAW DOWN AND FINISH SAMPLES SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING MATERIALS. 11.ALL FINISHES SHALL BE INSTALLED AND/ OR APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S FINISH SPECIFICATIONS AND INSTRUCTIONS, IN A MANNER CONSISTENT WITH THE HIGHEST QUALITY STANDARDS OF WORKMANSHIP. FINISHES SHALL MEET OR EXCEED ALL APPLICABLE CODE REQUIREMENTS. 12.ALL SURFACES TO BE PAINTED SHALL RECEIVE (1) COAT PRIMER AND A MINIMUM OF (2) FINISH COATS. REFER TO SPECIFICATION DRAWING I-501 SECTION 09900 PAINTS AND COATINGS FOR PAINT FINISHES. 13.DO NOT PAINT PRE-FINISHED ITEMS AND SURFACES (E.G. ANODIZED ALUMINUM, BAKED ENAMEL PANELS, PLASTIC SWITCH PLATES, ETC.), UNLESS OTHERWISE NOTED. 14. ALL REGISTERS, VENTS, GRILLES, DIFFUSERS, ELECTRICAL OUTLET COVERS, AND ACCESS PANELS SHALL BE PRE-FINISHED TO MATCH ADJACENT WALL SURFACES, UNLESS OTHERWISE NOTED. 15.ALL WALLS SCHEDULED TO RECEIVE PAINT SHALL BE PAINTED CORNER TO CORNER AND FLOOR TO CEILING, UNLESS OTHERWISE NOTED. 16. PROVIDE ADA COMPLIANT MARBLE THRESHOLDS AT ALL TILE FLOORING WHERE FLOORING CHANGE OCCURS. SUBMIT SAMPLES FOR SELECTION BY ARCHITECT. 12.FLOORING CONTRACTOR SHALL COORDINATE DIFFERENT FLOORING MATERIAL THICKNESSES. FINISHED FLOORING MATERIALS SHALL HAVE SMOOTH GRADUAL TRANSITIONS FROM DIFFERENT MATERIALS. INSTALLER SHALL PROVIDE LEVEL LASTIC UNDERLAYMENT TO RAISE DISSIMILAR MATERIALS HEIGHTS AS REQUIRED. 13.TILE SUB-CONTRACTOR SHALL PROVIDE AND INSTALL METAL TRIM FOR WALL AND BASE TILE WHERE INDICATED. 14.CERAMIC TILE GROUT JOINTS TO BE 1/8", U.N.O. 15.EPOXY FLOORING- TEK-CRETE URETHANE CEMENT: INSTALLER TO PROVIDE AND INSTALL SCHLUTER METAL TRANSITION FOR ALL ADJACENT FLOORING TYPES AND HEIGHTS. HEIGHTS MAY VARY. 16.PROVIDE ALLOWANCE FOR THERMOPLASTIC WALL MOUNTED SIGNAGE TO INCLUDE ROOM NAME, NUMBER AND BRAILLE AS REQUIRED PER 521 CMR AND ADA REGULATIONS. REFER TO SHEET I-500 FOR REQUIRED MOUNTING HEIGHTS. JSP/AMC DMG/ AMC Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_I-100 FINISH FLOOR PLANS, SCHEDULES, NOTES, & DETAILS.dwgLast save: Oct 10, 2019 - 2:12pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID I 100 FINISH FLOOR PLANS, SCHEDULES, NOTES, & DETAILS FINISH NOTES 1.SPECIFIED FINISHES PENDING TENANT'S APPROVAL. 2.WHERE EXISTING CONSTRUCTION IS AFFECTED PATCH/REPAIR SO THAT ALL NEW FINISHES SHALL MATCH, BLEND AND ALIGN WITH EXISTING ADJACENT SURFACES. THIS IS TYPICAL FOR ALL SURFACES. 3.PROVIDE FLOORING TRANSITIONS BETWEEN DISSIMILAR MATERIALS. 4.LEVEL ALL FLOORS TO 1/8" IN 10'-0" FLASH-PATCH WITH LEVELASTIC @ TRANSITION. 5.G.C. TO REMOVE ANY EXISTING DOOR CLOSERS PRIOR TO PAINTING AND RE-INSTALL WHEN PAINTING IS COMPLETE. 6.PATCH & REPAIR ALL EXISTING WALLS IN AREAS TO RECEIVE NEW FINISHES PER SCHEDULE, (TYP.) 7.ALL GWB WALLS ARE TO RECEIVE ONE COAT PRIMER AND TWO COATS OF FINISH PAINT. COLORS AND FINISH AS SCHEDULED. SUBMIT PRODUCT DATA AND COLOR CHIPS TO ARCHITECT. 8.EXISTING METAL CEILING PANELS TO BE SALVAGED AND STORED FOR DECORATIVE RE-USE. REFER TO I-100 FOR LOCATIONS. ARCHITECT TO SELECT FOR RE-USE. SELECTED METAL PANELS TO BE CLEANED AND SEALED PRIOR TO INSTALLATION. 9.G.C. TO PROVIDE NEW WALL MOUNTED ROOM SIGNS TO INCLUDE ROOM NAME, NUMBER AND BRAILLE AS REQUIRED PER 521 CMR AND ADA REGULATIONS. REFER TO SHEET GC-201 FOR REQUIRED MOUNTING HEIGHTS 10.METAL DOOR AND WINDOW FRAMES TO BE PAINTED ADJACENT WALL COLOR WITH SEMI-GLOSS FINISH. COLOR SPECIFIC TAGS NOT SHOWN ON FINISH SPECIFICATION OR FINISH PLANS. 11.ALL EXISTING SURFACES TO REMAIN SHALL BE P&R AND FINISHED AS SCHEDULED. FINISH SPECIFICATION REFER TO I-100 & I-300/ 301 FOR LOCATIONS TAG MATERIAL MANUF.SIZE/ FINISH STYLE COLOR/ FINISH:CONTACT LOCATION INSTALLATION REMARKS MAT WALK OFF CARPET TILE MOHAWK 24"x 24"TUFF STUFF II: STEP IN STYLE ll 983 IRON ORE Katy Coyman-Huntress katy_coyman-huntress@mohawkind.com 617-901-7734 100 ENTRY VESTIBULE BRICK ASHLAR - T-1 PORCELAIN TILE - FLOOR CROSSVILLE 12" x 12" x 3/8"BASALT AV294 MAFIC Lori Bowers lbowers@crossvilleinc.com 617-947-0057 106 ACCESSIBLE RESTROOM, 205 BATH ASHLAR PROVIDE FLASH PATCH, LEVELING, MORTAR BED AS RECOMMENDED BY MANUFACTURER; REFER TO I-102 FOR TILE PATTERNS; GROUT: MAPEI #47 CHARCOAL T-2 CERAMIC GLAZED WALL TILE- ACCENT GARDEN STATE TILE 4" x 8"MARZO AZURE Pamela King pking@gstile.com 203-434-5547 102 SALES AREA: WALL ACCENTS ASHLAR CEMENT BOARD BACKER GROUT: MAPEI #111 HICKORY 1/16" GROUT JOINT SDT STATIC DISSAPATIVE TILE ARMSTRONG 12"x 12"SDT 51956 FOSSIL GRAY Jasmine Bulmer jbulmer@armstrongflooring.com 1-403-463-2601 105 IT CLOSET QUARTER TURN INSTALL - CPT CARPET - BROADLOOM T.B.D.T.B.D.$25.00SY/ INSTALLED TBD --PREP FLOOR & INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS REFER TO I-100; I-102 LT-1 LINOLEUM COMPOSITION TILE FORBO 13.11" X 13.11" X 0.08"MARMOLEUM 2.0mm MCT TILE 629 EIGER Matt O'Keefe matt.okeefe@forbo.com 978-810-1045 103 ELEC. ROOM, 103A HALL, 204 BREAK ROOM, 207 VAULT -- LT-2 LINOLEUM COMPOSITION TILE FORBO 13.11" X 13.11" X 0.08"MARMOLEUM 2.0mm MCT TILE T3233 SHITAKE -204 BREAK ROOM -- WD-1 RECLAIMED WOOD: TONGUE & GROOVE PLANK ELMWOOD 3/4" THICK x 7" WIDE RANDOM LENGTHS ANTIQUE OAK; COMMERCIAL FINISH SINGLE MALT Brent Kroh kroh@elmwoodreclaimedtimber.com 816-779-7300 FLOOR: 102, 102A, 104 SEE I-300 FOR ADDITIONAL LOCATIONS -COMMERCIAL GRADE, STANDARD FINISH WD-2 RECLAIMED WOOD: PEEL & STICK PLANKS STIKWOOD 3/16" THICK x 5" WIDE. RANDOM LENGTHS RECLAIMED WEATHERED WOOD RECLAIMED WEATHERED WOOD Steve Andrade steve@stikwood.com 866-226-8354x 2121 SEE I-300, I-302 FOR LOCATIONS REVIEW MANUFACTURERS INSTALLATION INSTRUCTIONS. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS - WD-3 RECLAIMED WOOD ELMWOOD 3/8" THICK x 3"-5"W x 2'-8'L RANDOM WIDTHS & LENGTHS THIN CUT RUSTIC PANELING - Brent Kroh kroh@elmwoodreclaimedtimber.com 816-779-7300 CEILINGS WHERE SPECIFIED REFER TO A-200 $15.00/ SF: MATERIALS ONLY PROVIDE PLANS / ELEVATIONS TO MANUFACTURER FOR ACCURATE PRICING. WD-4 RECLAIMED WOOD: PEEL & STICK PLANKS STIKWOOD 3/16" THICK x 5" WIDE. RANDOM LENGTHS RECLAIMED WEATHERED WOOD PACIFICA --SEE I-300 FOR LOCATIONS REVIEW MANUFACTURERS INSTALLATION INSTRUCTIONS. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS - WD-5 RECLAIMED WOOD: CABINET ACCENT TRIM ELMWOOD 3/4" THICK x 5" WIDE SQUARE EDGES ANTIQUE OAK RUSTIC --MILLWORK ACCENT REFER TO 1-300 FOR LOCATIONS MANUFACTURER TO FINISH SQUARE EDGES PROVIDE MILLWORK PLANS / ELEVATIONS TO MANUFACTURER FOR ACCURATE PRICING. WD-6 RECLAIMED WOOD: EXTERIOR GRADE w/ touch up stain ELMWOOD 3/4" THICK x 7" WIDE ANTIQUE OAK; EXTERIOR GRADE, COMMERCIAL FINISH SINGLE MALT -REFER TO EXTERIOR ELEVATIONS. MITERED AT CORNER WOOD WRAP. MANUFACTURER TO PROVIDE TOUCH UP STAIN FOR CUT AND MITERED EDGES. OUTSIDE CORNER TO BE MITERED. EXTERIOR WALL APPLICATION: AIR SPACE REQ'D. REFER TO EXTERIOR WALL SECTIONS. MANUFACTURER TO PROVIDE FINISH FOR EXTERIOR APPLICATION. MTL METAL EDGE TRIM STIKWOOD 4' LENGTHS METAL EDGE TRIM BLACK -ACCESSIBLE BATHROOM 106, BATH 205 REVIEW MANUFACTURERS INSTALLATION INSTRUCTIONS. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS - B-1 RUBBER BASE- COVE JOHNSONITE 4" ROLL TRADITIONAL RUBBER WALL BASE TBD Karen Gilligan karen_gilligan@nfdist.com 508-397-1583 103, 103A, 105, 204, 207 -- B-2 RUBBER BASE - STRAIGHT JOHNSONITE 4" ROLL TRADITIONAL RUBBER WALL BASE TBD -CARPETED AREAS -- B-3 WOOD BASE PAINT GRADE POPLAR 5"h FLAT STOCK -T.B.D.-THROUGHOUT, U.N.O.-- B-4 CERAMIC TILE BASE WITH SCHLUTER TRIM CROSSVILLE 4" H x 12" CUT FROM T-1 BASALT METAL EDGE AT TOP OF BASE: JOLLY ABGB BASALT - AV294 MAFIC METAL EDGE - BRUSHED ANTIQUE BRONZE -ENTRANCE VESTIBULE -- SN STAIR NOSING JOHNSONITE 4" ROLL SLIMLINE STAIR NOSING SLN-XX-A -STAIR 1 -- CA CASING PAINT GRADE POPLAR 3.5" FLAT STOCK -T.B.D.-EXTERIOR WALL WINDOWS; CASING ONLY: DOORS WHERE NOTED -- WP SALVAGED EXISTING METAL CEILING- WALL ACCENT EXISTING CEILING ARCHITECT TO SELECT RE-PURPOSED EXISTING TIN CEILING SECTION FOR WALL ACCENTS EXIST. or TBD -102 SALES REFER TO I-100, I-___ FOR LOCATIONS METAL CEILING SHALL BE CLEANED AND SEALED WITH PROTECTIVE COATING BEFORE RE-INSTALLING CONTRACTOR SHALL SALVAGE AND STORE EXISTING METAL CEILING PIECES. ARCHITECT TO SELECT FOR WALL ACCENT AREAS. WC WALL COVERING CHILEWICH 72"MINI BASKETWEAVE PISTACHIO Lisa Walters lwalters@watersolutions.com 617-513-6336 100 ENTRY VESTIBULE, 104 HALL -- FRP 4' HIGH FIBERGLASS REINFORCED PANEL MARLITE 4' x 8' x 3/32"STANDARD FRP SMOOTH FINISH COLOR: S 490N SMOOTH GRAY -JANITOR CLOSETS SINK WALLS; 4'-0" HIGH PVC TRIM: INSIDE CORNER, DIVISION, EDGE P-1 PAINT- FIELD SHERWIN WILLIAMS EGGSHELL PROMAR 200 INTERIOR LATEX TBD Mark Weiner mark.t.weiner@sherwinwilliams.com 617-438-1408 OFFICES AND COMMON AREAS, U.N.O.-- P-2 PAINT- FIELD SHERWIN WILLIAMS EGGSHELL PROMAR 200 INTERIOR LATEX TBD ENTRANCE VESTIBULE AND SALES AREA, U.N.O.-- P-3 PAINT- ACCENT SHERWIN WILLIAMS EGGSHELL PROMAR 200 INTERIOR LATEX TBD --- P-4 PAINT- ACCENT SHERWIN WILLIAMS EGGSHELL PROMAR 200 INTERIOR LATEX TBD --- P-5 PAINT- CEILING/ SOFFIT SHERWIN WILLIAMS FLAT PROMAR 200 INTERIOR LATEX TBD GWB CEILINGS/ SOFFITS -- P-6 PAINT- TRIM SHERWIN WILLIAMS SEMI-GLOSS PROMAR 200 INTERIOR LATEX TBD --- P-7 PAINT- EXTERIOR SHERWIN WILLIAMS EGGSHELL PROMAR 200 EXTERIOR LATEX TBD EXISTING VERTICAL SIDING -- P-8 PAINT-TRIM SHERWIN WILLIAMS SEMI-GLOSS PROMAR 200 INTERIOR LATEX TBD TOE KICK- DISPLAY CABINET ACP-1 ACOUSTICAL CEILING PANEL & 9/16" GRID USG, or EQ.2' x 2' x 3/4"MARS ORION 60 SQ ACOUSTICAL PANEL WHITE Steve Adelman SAdelman@usg,org 781-281-5237 REFER TO A-200 FOR LOCATIONS -ACP STYLE SPECIFIED FOR CURRENT LOCATIONS ONLY LOCATIONS QS-1 QUARTZ SURFACING WILSONART 63" x 126" x 2cm Q4027L LUCCA --COUNTERS, WHERE SPECIFIED -EASED EDGE SS-1 SOLID SURFACING WILSONART 1/2"TBD --BATH 205 VANITY TOP & 4" BACKSPLASH -EASED EDGE PL-1 PLASTIC LAMINATE- VERTICAL GRADE AROBORITE -CASHMERE FINISH P-331 CA CHARCOAL CHAMOIS Kelly Palumbo kelley.palumbo@arborite.com 978-872-8993 REFER TO I-300,301, 302 FOR LOCATIONS -- PL-2 PLASTIC LAMINATE- VERTICAL GRADE LAB DESIGNS.4' x 8'TX FINISH PG 040 TX STEEL MESH Anne Nicholas annen@surfacematerials.com 857-488-3148 REFER TO I-300,301, 302 FOR LOCATIONS -PROVIDE 4" BACKSPLASH AT COUNTERS PL-3 PLASTIC LAMINATE- VERTICAL GRADE LAB DESIGNS.4' x 8'BARK CUT FINISH PC 223 BC TEAL OXIDE -REFER TO I-300,301, 302 FOR LOCATIONS -- PL-4 PLASTIC LAMINATE- HIGH WEAR LAMINATE LAMINART -VELLUM FINISH 9 213-E SLATE GRAY -SHELVING, WORK COUNTERS. REFER TO I-100, I-300,301-302 FOR LOCATIONS -PROVIDE 4" BACKSPLASH AT COUNTERS PULLS METAL PULL RICHELIEU 5 3/16" BRUSHED OIL RUBBED BRONZE TRADITIONAL METAL PULL 2377 --CABINETS -- PULLS METAL PULL RICHELIEU BRUSHED OIL RUBBED BRONZE TRADITIONAL METAL PULL 8233 --DRAWERS -- LOCK CABINET/ DRAWER CAM LOCK -3/4"; OIL RUBBED BRONZE ---DRAWERS -CONFIRM LOCKED CABINET LOCATIONS SHOWN ON DRAWINGS WITH OWNER PF PRIVACY FILM 3M OR EQ.-T.B.D. WHITE OPAGUE TBD -FIRST FLOOR EXTERIOR GLAZING -- SIGN INTERIOR SIGNAGE INPRO OR EQ.PVC; 4x 4 (ROOM) & 6x 4 (ADA & OTHER) ADA SIGNS WHERE REQ'D; ROOM (9) & OTHER (3) SELF ADHESIVE CONTRASTING BACK AND COPY. COLORS & COPY T.B.D. ---ADA COMPLIANT. PROVIDE ALL SIGNAGE REQ'D BY CODE. PROVIDE INSTALLATION. WT WINDOW TREATMENTS- ROLLER SHADE ROLLEASE/ ACMEDA VARIES R SERIES, 3% OPENNESS. SQUARE FASCIA COLOR T.B.D. Rich Fredericks Royal Window Treatment 617-512-4549 --2ND FLOOR. TO BE FIELD MEASURED BY VENDOR PRIOR TO ORDERING MILLWORK: ·CABINETS: FLUSH OVERLAY P-LAM ON 3/4" MDF ·30"H UPPER CABINETS ·P-LAM ADJUSTABLE INTERIOR SHELVING ON 3/4" MDF, UPPER & LOWER CABINETS ·EXPOSED/ OPEN CABINETS/ SHELVING AREAS AT POS STATIONS TO BE P-LAM. ·BLACK MELAMINE CABINET/ DRAWER INTERIOR ·SOFT CLOSE DRAWER HARDWARE ·CABINET & DRAWER PULLS AS SPECIFIED ·CABINET TOE KICKS: P-LAM ·CONCEALED HINGES ·ADA COMPLIANT APPLIED TOE-KICK BY RICHELIEU AT BREAK ROOM SINK CABINET ·PAINTABLE SILICONE SEALANT AT BACKSPLASH ·PROVIDE BLOCKING/ SHIMS MILLWORK- MISC: ·DISPENSARY: RECLAIMED BASE CABINET WOOD ACCENTS ·SHELVING: PLAM; HEAVY DUTY BLACK STANDARDS AND BRACKETS . ·SHELVING LOCATIONS: ··STORAGE 201 ··PACKAGING 202 ·HEAVY DUTY RAKKS BRACKETS, PAINTED. COLOR BY ARCHITECT ·P-LAM ALL SIDES ON 3/4" MDF, U.N.O. ·WORK COUNTERS: PROVIDE GROMMETS AT ALL DATA LOCATIONS ·POS STATIONS: PROVIDE GROMMETS AT SHELF UNDER CASH BOXES. ·POS STATIONS: PROVIDE PLAM ADJUSTABLE INTERIOR & OPEN SHELVING. ·PAINTABLE SILICONE SEALANT AT BACKSPLASH ·PROVIDE COUNTER HEIGHT GFCI OUTLETS AT BREAK ROOM 204 AND BATH 205. ·APPLIANCE CUT SHEETS ARE TO BE REVIEWED PRIOR TO FABRICATION ·BREAK ROOM: PROVIDE UNDER CABINET LED LIGHTING ·G.C. TO COORDINATE REQUIREMENTS & LOCATIONS FOR CABINET LOCKS WITH OWNER · QUARTZ/ SOLID SURFACE COUNTERS TO HAVE EASED EDGE ·INTERIOR WINDOW TRIM: FLAT HEADER, JAMBS, SILL AND APRON; PAINTED ·FIRST FLOOR INTERIOR DOOR TRIM: FLAT HEADER, JAMBS, SILL AND APRON; PAINTED, WHERE NOTED · JSP/AMC DMG/ AMC Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_I-100 FINISH FLOOR PLANS, SCHEDULES, NOTES, & DETAILS.dwgLast save: Oct 10, 2019 - 2:12pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID I 101 FINISH SPECIFICATIONS & NOTES ADJACENT TENANT - (N.I.C.) ADJACENT TENANT - (N.I.C.) 1 2 3 4-ADA ONLINE PICK-UP? basement access millwork (bud bar?) displaydisplaydisplay FIRST FLOOR FINISH PLAN ENTRY VESTIBULE 100 SALES AREA 102 EXISTING STORAGE SHED (N.I.C.) HALL 104 STAIR 1MAT WD-1 WD-1 LT-1 LT-1 POS STATIONS 102A WD-1 LT-1 6 T-1 11 3 CPT-1 2 3 ACCESSIBLE RESTROOM 106 EXISTING ELEC. RM 103 HALL 103A JANITOR CLOSET 105 D SDT IT CLOSET 101A 31'-10"17'-412" 5'-0" 21'-1112"5'-0"7'-912"9'-5"912"3 SECURITY OFFICE 101 WD-1 attic access countertop wall shelving wall shelving STAIR 1 OFFICE 203 CORRIDOR 200 BATH 205 COUNTING ROOM 206 EXISTING OUTDOOR DECK CPT-1 LT-1 CPT-1 CPT-1 CPT-1 PACKAGING 202 CPT-1 5 5 4 STOR. CLO. 201 CPT-1 VAULT 207 D TWO COLOR PATTERN T.B.D. D D D D D D 7'-1012"14'-0"2'-1"1'-0"2'-112"3'-0"5'-61 4"1'-018"JAN. CLO. 200A LT-1 BREAK ROOM 204 LT-1 LT-2 SCALE: 2 WOOD TO TILE N.T.S.5/16"PROVIDE ADA COMPLIANT MARBLE THRESHOLD 1/2" MAX. ,TYP. TILE SCALE: 3 VINYL TO WOOD N.T.S. WOOD FLOOR VINYL 3/16" SCHLUTER VINPRO S TRANSITION STRIP FOR RESILIENT FLOORING; BRONZE FINISH 1/2" PLYWOOD UNDERLAYMENT3/4"SCALE: 5 VINYL TO CARPET N.T.S. CARPET VINYL 1/4" SCHLUTER VINPRO S TRANSITION STRIP FOR RESILIENT FLOORING; BRONZE FINISH 1/8" SCALE: 1 CARPET TO WOOD N.T.S. SCALE: 4 CARPET TO TILE N.T.S.5/16"LEVELASTIC OR REDUCER CARPET PROVIDE ADA COMPLIANT MARBLE THRESHOLD 1/2" MAX. ,TYP. TILE 3/16"LEVELASTIC OR REDUCER WOOD FLOOR JOHNSONITE SLIM LINE RUBBER TRANSITION STRIP SLT-XX-F COLOR TO MATCH RUBBER BASE AS SCHEDULED WOOD FLOORCARPET 3/4"3/4"JSP/AMC DMG Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_I-100 FINISH FLOOR PLANS, SCHEDULES, NOTES, & DETAILS.dwgLast save: Oct 10, 2019 - 2:12pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID I 102 FLOOR PATTERNS SCALE: 1 FLOOR PATTERNS 1/4"=1'-0" FIRST FLOOR PLAN- SCALE: 2 FLOOR PATTERNS 1/4"=1'-0" SECOND FLOOR PLAN- SCALE: 3 FLOOR ING TRANSITIONS NTS ADJACENT TENANT - (N.I.C.) 1 2 3 4-ADA ONLINE PICK-UP? basement access millwork (bud bar?) displaydisplaydisplay4 I-300 A 4 I-300 C 2 I-300A 2 I-302 A 3 I-300 A 2 I-302 DC 4 I-300 B 4 I-300D SALES AREA 102 EXISTING ELEC. RM 103 POS STATIONS 102A HALL 103A 2 I-302 B 5 I-300 A 11'-11"18'-412"2'-6" 4'-0" 1'-612" 7'-47 8"6'-13 4"3'-2"SALVAGED METAL CEILING 6'-0" T-2 PAINTED PAINTED- (ACCENT COLOR) WALL TILE ACCENT: COPPER PATINA COLOR SALVAGED CEILING PIECES TO BE SELECTED BY ARCHITECT. APPLIED TO FINISHED PTD. GWB. B-3 ELEVATION A RECLAIMED WOOD CEILING ACCENT 22'-03 8" MONITORS: MENU DISPLAY AREA. MONITOR SIZE & QUANTITY TO BE PROVIDED BY OWNER WD-2/4: SUBSTRATE TO BE PRIMED WITH TINTED PRIMER. PRIMER MUST BE A NON-SILICONE TYPE OF PRIMER. PRIMER IS TO DRY AT LEAST 72 HOURS BEFORE WOOD IS ADHERED. 8'-9" WD-3 . 7'-6" U.S. GWB . WP V.I.F. PROVIDE IN WALL BLOCKING AND MOUNTING BRACKETS AS REQ'D. COORDINATE POWER NEEDS TO BE PROVIDED BY OWNER CA CA TO CEILING, V.I.F. SIM.634"MTL WOOD TO WRAP CORNER PROVIDE ALTERNATE PRICING USING WD-3 PAINTED- (ACCENT COLOR) 8'-9" WD-3 . WD-2 PAINTED BULLNOSE & WOOD TRIM, STAINED FINISH, T.B.D.858"15'-1118" PAINTED CA ELEVATION A WD-4 WD-2=75% WD-2/4: SUBSTRATE TO BE PRIMED WITH TINTED PRIMER. PRIMER MUST BE A NON-SILICONE TYPE OF PRIMER. PRIMER IS TO DRY AT LEAST 72 HOURS BEFORE WOOD IS ADHERED. HEMPESTTHE B-3 PROVIDE ALTERNATE PRICING USING WD-3 RECLAIMED WOOD CEILING ACCENT 7'-6" U.S. GWB . CA PF A PF A ELEVATION A & CELEVATION B & D DISPLAY CASES N.I.C. RECESSED TOE-KICK, PTD. QS-1 QS-1 RECLAMIED WOOD & P-LAM CABINET STORAGE/ DISPLAY 5"5" 2'-6"2'-6" 5"5" WD-5 TYPICAL PL-3 PROVIDE LOCKS, TYP. RECESSED TOE-KICK, PTD. PL-3 3'-6"2'-6"6'-2" PROVIDE ADJUSTABLE SHELVING. PL-1 AT CABINET INTERIORS QUARTZ COUNTERS: EASED EDGE, TYP. 8'-9" WD-3 . WOOD TRIM, PAINTED ELEVATION A T-2 8'-0" U.S. GWB SOFFIT WP 8'-9" WD-3 B-3 T-2: WRAP RETURN PAINTED SCHLUTER JOLLY SCHLUTER JOLLY PAINTED SALVAGED METAL CEILING 6'-1112" JSP AMC #DATE REVISION Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_I-300 ENLARGED MILLWORK PLANS & ELEVATIONS.dwgLast save: Oct 10, 2019 - 2:12pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID I 300 ENLARGED MILLWORK PLANS & ELEVATIONS SCALE: 1 FIRST FLOOR 1/4"=1'-0" ENLARGED PLAN- SCALE: 2 SALES AREA 1/2"=1'-0" ELEVATIONS- SCALE: 4 SALES AREA 1/2"=1'-0" ELEVATIONS- SCALE: 3 SALES AREA 1/2"=1'-0" ELEVATIONS- SCALE: 5 SALES AREA 1/2"=1'-0" ELEVATIONS- 8'-0" U.S. GWB CLNG 2'-6"ELEVATION BELEVATION CELEVATION D 101 1 5 I 302 C B-3 PAINTED PAINTED PAINTED PL-1 PL-1 PAINTED RAKKS HEAVY DUTY BRACKETS, PTD. TYP. CA METAL FRAMES PAINTED TO MATCH ADJACENT WALL COLOR; COLOR T.B.D. SEMI-GLOSS FINISH, TYP., PF B-3 B-3B-3 PROVIDE GROMMETS AT OUTLET LOCATIONS, TYP. P-LAM COUNTER & BACKSPLASH 101A 1 ELEVATION A CA CA display ENTRY VESTIBULE 100 SECURITY OFFICE 101 HALL 104 STAIR 106 RESTROOM 107 IT CLOSET 105 4 I-301 D C B A A 2 I-301 A 3 I-301 C B A D7'-912"2'-0" JAN CLOSET 105 2 I-303 B A D C 1'-10"1'-6"0'-0" FIN. FL. 8'-0" U.S. GWB CLNG B-3 ELEVATION A WC-1 PAINTED METAL FRAMES PAINTED TO MATCH ADJACENT WALL COLOR; COLOR T.B.D. SEMI-GLOSS FINISH, TYP., CA CA 100 3100 2 CA PF PF 101 1D PF B-3 ELEVATION A 100 1 STR1 1 C ELEVATION BELEVATION CELEVATION D 0'-0" FIN. FL. 8'-9" U.S. WOOD PLANK CEILING WC-1 PAINTEDPAINTED METAL FRAMES PAINTED TO MATCH ADJACENT WALL COLOR; COLOR T.B.D. SEMI-GLOSS FINISH, TYP., METAL FRAMES PAINTED TO MATCH ADJACENT WALL COLOR; COLOR T.B.D. SEMI-GLOSS FINISH, TYP., PFPF B-3 B-3 CA CA CA D CA PF WC WC 100 2 100 3 PFPF JSP AMC Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_I-300 ENLARGED MILLWORK PLANS & ELEVATIONS.dwgLast save: Oct 10, 2019 - 2:12pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID I 301 ENLARGED MILLWORK PLANS & ELEVATIONS SCALE: 3 ENTRANCE/ EXIT VESTIBULE 1/2"=1'-0" ELEVATIONS- SCALE: 1 FIRST FLOOR 1/4"=1'-0" ENLARGED PLAN- SCALE: 2 VESTIBULE/ SECURITY 1/2"=1'-0" ELEVATIONS- SCALE: 4 SECURITY OFFICE 1/2"=1'-0" ELEVATIONS- PL-2 QS-1 PAINTED WD-5 WD-5 ELEVATION D ELEVATION C EQ. 2'-6"2'-6" B-3 GATE & PANEL: LATCH & PROVIDE LOCK; BRUSHED BRONZE PL-4 3'-0"4'-55 8"1'-6"434"5"3'-0"HEMPESTTHE PULLS AS SPECIFIED; PROVIDE LOCKS WHERE SHOWN TYP. PROVIDE DATA/ ELEC. OWNER TO PROVIDE DATA/ ELEC. NEEDS AT POS STATIONS. PROVIDE ADJ. SHELF; ALL CAB. INTERIORS TO BE BLACK MELAMINE, TYP. 1'-6"1'-55 8" PL-4: OPEN AREA & ADJ. SHELVING, TYP. SIGNAGE/ GRAPHICS BY TENANT CASH DRAWER O.F.C.I. CASH DRAWER O.F.C.I. CASH DRAWER O.F.C.I. OPEN 3'-3" 7'-6" U.S. GWB . 7'-6" U.S. GWB . PL-1 5"PL-2 CASH DRAWER O.F.C.I. PL-2 FINISHED FLAT EDGE BY MFR., TYP. QUARTZ COUNTERS: EASED EDGE, TYP. QS-1 PL-2 PL-1 TYP. PL-2 RETURN PROVIDE ADJUSTABLE SHELVING. PL-1 AT CABINET INTERIORS, TYP. PULLS AS SPECIFIED, TYP. OPEN OPEN OPEN OPEN OPEN OPEN OPEN PL-4 P-LAM FILLER, TYP. P-LAM FILLER, TYP. P-LAM FINISH END, TYP. EQ.44" TYP.CA PL-2 FACE, DRAWERS, DOORS. PL-1 OPEN INTERIOR, TYP. MTL PROVIDE GROMMETS AT CASH DRAWERS, TYP. WD-5 WD-2 QS-1 ELEVATION A RETURN WD-2 TO GATE 5'-0" WD-2: SUBSTRATE TO BE PRIMED WITH TINTED PRIMER. PRIMER MUST BE A NON-SILICONE TYPE OF PRIMER. PRIMER IS TO DRY AT LEAST 72 HOURS BEFORE WOOD IS ADHERED.3'-0"112"ELEVATION B 7'-6" U.S. GWB . WD-2 QS-1 PLAM GATE 2'-6"3'-0"2'-10"MTL MTL 7'-6" U.S. GWB . MTL PL-1 QUARTZ COUNTERS: EASED EDGE, TYP. PL-2 WD-5: FINISHED SQUARE EDGE PROVIDED BY MANUFACTURER. WD-2: SUBSTRATE TO BE PRIMED WITH TINTED PRIMER. PRIMER MUST BE A NON-SILICONE TYPE OF PRIMER. PRIMER IS TO DRY AT LEAST 72 HOURS BEFORE WOOD IS ADHERED.QS-1 412"PLAM PANEL 412"412"MTL B-3 B-3 TENANT - (N.I.C.) 1 2 3 4-ADA ONLINE PICK-UP?display4 I-300 C 2 I-300A 2 I-302 A 3 I-300 A 2 I-302 DC SALES AREA 102 EXISTING ELEC. RM 103 POS STATIONS 102A HALL 103A 2 I-302 B 11'-11"18'-412"2'-6" 4'-0" 1'-612" 73 CL 6'-11"1'-0"3'-212"4'-8"3'-2"2'-1"4 I302 A BREAK ROOM 204 REFDW U/C LIGHT 3 I200 2 I200 P-LAM FINISHED PANEL RETURN, TYP. 7'-6" +/- 7'-9" U.S. GWB CLNG ELEVATION A 2'-6"2'-6" P-LAM COUNTER & BACKSPLASH P-LAM 3'-2" P-LAM 2'-10" 1 I200 4'-6" PL-4 PL-2 PL-1 PL-4 APPLIANCES, BLACK FINISH, TYP. 101 4"2'-6"2'-6" PULLS AS SPECIFIED, TYP. countertop wall shelving 14'-0"2'-1"1'-0"PACKAGING 2022'-6"5 I 302 RAKKS HEAVY DUTY BRACKETS, PTD. TYP. B-2 PROVIDE GROMMETS AT OUTLET LOCATIONS, TYP.1'-6"1'-0"PAINTED 202 1 PL-4 P-LAM COUNTER & BACKSPLASH PL-4 JSP AMC Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_I-300 ENLARGED MILLWORK PLANS & ELEVATIONS.dwgLast save: Oct 10, 2019 - 2:12pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID I 302 ENLARGED MILLWORK PLANS & ELEVATIONS SCALE: 1 POS COUNTER 1/4"=1'-0" ENLARGED PLAN- SCALE: 2 POS COUNTER 1/2"=1'-0" ELEVATIONS- SCALE: 3 BREAK ROOM 1/4"=1'-0" ENLARGED PLAN- SCALE: 4 BREAK ROOM 1/2"=1'-0" ELEVATION- SCALE: 3 PACKAGING 1/4"=1'-0" ENLARGED PLAN- SCALE: 4 PACKAGING 1/2"=1'-0" ELEVATION- 1. G.C. TO PROVIDE AND INSTALL ALL INTERIOR BUILDING SIGNAGE REQUIRED BY CODE AND AS SPECIFIED. 2. INSTALL USING DOUBLE FACED TAPE AND SILICONE ADHESIVE, AS RECOMMENDED BY MANUFACTURER. 3. INSTALL ALL SIGNAGE LEVEL & PLUMB WITH FLOOR AND WALL. 4. REFER TO A-601 FOR ADA COMPLIANT MOUNTING HEIGHTS. 5. PROVIDE SIGNAGE SUBMITTAL, SCHEDULE AND LOCATION PLANS. 6. SIGN COLORS & FONTS TO BE SELECTED BY ARCHITECT. 7. ROOM NAMES SHOWN ARE FOR DESIGN PURPOSES ONLY. FINAL ROOM NAMES TO BE REVIEWED, EDITED AND SIGNED OFF BY CLIENT BEFORE FABRICATION. NOTES RESTROOM SCALE: 2 ACCESSIBLE RESTROOM SIGN 6"=1'-0" TYPE 28"6" CODE COMPLIANT VINYL APPLIED GRAPHICS RAISED BRAILLE LETTERING, TACTILE SANS SERIF UPPERCASE TEXT TO CONTRAST WITH BACKPLATE. RAISED POLYMER LETTERS 5/8" HIGH. QUANTITIES & COPY SHOWN ARE NOT FINALIZED AND SUBJECT TO CHANGE. TYPE 1 = 6 TYPE 2 = 1 TYPE 3 = 1 TYPE 4 = 3 QUANTITIES ELEC. SCALE: 4 MECH., ELEC., JAN. & CLOSETS 6"=1'-0" TYPE 43"6" RAISED BRAILLE LETTERING, TACTILE SANS SERIF UPPERCASE TEXT TO CONTRAST WITH BACKPLATE. RAISED POLYMER LETTERS 5/8" HIGH. SCALE: 3 STAIR 6"=1'-0" TYPE 3 STAIR 18"6" RAISED BRAILLE LETTERING, TACTILE SANS SERIF UPPERCASE TEXT TO CONTRAST WITH BACKPLATE. RAISED POLYMER LETTERS 5/8" HIGH. SCALE: 1 SPECIALITY/ SAFETY 6"=1'-0" TYPE 1- 6"8"BEFORE ENTERING RAISED BRAILLE LETTERING, TACTILE ACTUAL TEXT T.B.D. & WILL VARY SANS SERIF UPPERCASE TEXT TO CONTRAST WITH BACKPLATE. RAISED POLYMER LETTERS 5/8" HIGH. SECURITY WITH CKECK-IN TEXT SHOWN FOR EXAMPLE ONLY. PLEASERIGID VINYL WITH SQUARE CORNERS RIGID VINYL WITH SQUARE CORNERS RIGID VINYL WITH SQUARE CORNERS RIGID VINYL WITH SQUARE CORNERS CODE COMPLIANT VINYL APPLIED GRAPHICS Drawing name: P:\Proj_2019\219001\300_CAD_and_Drawings\Contract_Dwgs\219001_I-500 SIGNAGE.dwgLast save: Oct 10, 2019 - 2:12pmChecked By: Job Number: Drawn By:Copyright 2019 by BKA Architects, Inc. The architectural plans, drawings, designs, specifications and other arrangements on this sheet are and shall remain the property of BKA Associates, Inc. No part thereof shall be copied, disclosed to others, or used in connection with any work or project, other than the specified project for which they have been prepared and developed, without the express knowledge and written consent of BKA Architects, Inc.DRAWING INFORMATION DRAWING NUMBER DRAWING TITLE REVISIONS ISSUED SEAL CONSULTANT OWNER/CLIENT ARCHITECT PROJECT 219001 HEMPEST DISPENSARY NORTHEMPTON, LLC. 2 CONZ STREET NORTHAMPTON, MA 01060 10/10/19 ISSUED FOR BID I 500 SIGNAGE JSP AMC