22B-043 296 NONOTUCK ST - MA ADAPTIVE TECH CENT SM-2021-0001
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: 8978
Map: 22B
Block: 001
Lot: ', SHEETMETAL PERMIT
. 'oo I
Permit: SHEETMETAL "
Category: renovation
Permit# SM-2021-0001 PERMISSION IS HEREBY GRANTED TO:
Project# JS-2021-000005
Est.Cost: $60,000.00 Contractor: License: Expires:
Fee Charged:$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020
Balance Due:$.00 Owner: NONOTUCK MILL LLC
#of Fixtures:!, Applicant: ROCK VALLEY HVAC
DigSafe# _ AT: 296 NONOTUCK ST-MA ADAPTIVE TECH CENTER
U seGroup
ConstClass
ISSUED ON: 3 I-Jul-2020 AMENDED ON: EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
RENO LOWER LEVEL FOR MA ADAPTIVE TECH CENTER
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2021-000328 31-Jul-20 1337 $50.00
212 Main Street,Phone:(413)587-1240,Fax:(413).587-1272,Email:lhasbrouck@northamptonma.gov
GeoTMS*2020 Des Lauriers Municipal Solutions,Inc.
_ ncur:ivL:u
Commonwealth of Massachusetts
041Ci Of Northampton I JUL 3 1 2020
City p �
PFPT. F SUILDIN9 INSPECTIONS
Date: 7/28/2020 Sheet Metal Permit permit
Estimated Job Cost: $60,000.00 Permit Fee: $ �j�
Plans Submitted: YES NO Plans Reviewed: YES NO
Business License# 824 Applicant License # SM2626
Business Information: Property Owner/Job Location Information:
Name: Rock Valley HVAC (Jesse Fortier) Name: Nonotuck Mill LLC
Street: 296c Nonotuck Street Street: 296 Nonotuck Street-Ma Adaptive Tech
City/Town: Florence City/Town: Florence
Telephone: (413) 535-7804 Telephone: (413) 737-7803
Photo I.D. required/Copy of Photo I.D. attached: YES NO
Staff Initial
J-1 /M-1-unrestricted license
J-2 / M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family Multi-family Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other V
Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: V Renovation:
HVAC Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
Install American Standard 7.5 ton packaged unit. Install spiral duct system.
Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000
Minimum fees for jobs without Building Permit$50.00 Residential, $100.00 Commercial
INSURANCE COVERAGE:
I have a current liar insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes® No ❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy ® Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee rims not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws, and that my signature on this permit application waive this requirement.
Check One Only
Owner ® Agent ❑
Signature of Owner or Owner's Agent
By checking this box®, I hereby certify that all of the details and information 1 have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation: YES NO j
PrjUoreSSIncn�tinnc
D-JAC
Find Incnvrtinn
D.Ue
Type of License:
By ® Master
Title ❑ Master-Restricted r--
City/Town
❑Journeyperson Signature of Licensee
Permit#
❑Journeyperson-Restricted SM262
License Number:
Fee$ ❑
X� � Check at www macs 93v� ldpi
Inspector Signature of Permit Approval
Rock Valley Project Summary Date: July 27,2020
Entire House By:
Rock Valley HVAC Inc.
296C NonotLK*Street,Florence,Ma 01062 Phone:(413)535-7804 Email:rockvalle^ac@yahoo.00m Web wwwroavalleytWac com License SM2626
Pro"ect Information
For: Ma Adaptive Tech,Nonotuck Mill LLC
296 Nonotuck Street, Florence,Ma 01062
Notes:
Desiqn Information
Weather: Greenfield(Worcester Dd),MA, US
Winter Design Conditions Summer Design Conditions
Outside db -2 'F Outside db 85 'F
Inside db 72 'F Inside db 68 'F
Design TD 74 'F Design TD 17 'F
Daily range M
Relative humidity 50 %
Moisture difference 42 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 100436 Btuh Structure 60460 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
piping 0 Btuh
Equipment load 100436 Btuh Use manufacturer's data n
Rate/swing multiplier 0.90
Infiltration Equipment sensible load 54414 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 40550 Btuh
Ducts 0 Btuh
Central vent(0 chn) 0 Btuh
Heating Cooling (none)
Area(ft) 8710 8710 Equipment latent load 40550 Btuh
Volume(ft) 78390 78390
Air changes/hour 0.37 0.19 Equipment Total Load(Sen+Lat) 94964 Btuh
Equiv.AVF(cfm) 483 248 Req.total capacity at 0.70 SHR 6.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80AFUE Efficiency 0 SEER
Heating Input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 'F Total cooling 0 Btuh
Actual airflow 4266 cfrn Actual airflow 4266 cfm
Air flow factor 0.042 cfm/Btuh Air flow factor 0.071 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.60
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-Pk wrightsoft 2020-Jt1-2816:29:47
Rigft-Sute®Urtversal 2019 19 0 19 RSU24598 Page 1
ACCA ...erstero\Desldop\Jobs\ATCMillkCrockerATC.rt{ Calc=MJ8 BuldingFront faces:SE