Loading...
22B-043 296 NONOTUCK ST - MA ADAPTIVE TECH CENT SM-2021-0001 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 8978 Map: 22B Block: 001 Lot: ', SHEETMETAL PERMIT . 'oo I Permit: SHEETMETAL " Category: renovation Permit# SM-2021-0001 PERMISSION IS HEREBY GRANTED TO: Project# JS-2021-000005 Est.Cost: $60,000.00 Contractor: License: Expires: Fee Charged:$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020 Balance Due:$.00 Owner: NONOTUCK MILL LLC #of Fixtures:!, Applicant: ROCK VALLEY HVAC DigSafe# _ AT: 296 NONOTUCK ST-MA ADAPTIVE TECH CENTER U seGroup ConstClass ISSUED ON: 3 I-Jul-2020 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: RENO LOWER LEVEL FOR MA ADAPTIVE TECH CENTER THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2021-000328 31-Jul-20 1337 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413).587-1272,Email:lhasbrouck@northamptonma.gov GeoTMS*2020 Des Lauriers Municipal Solutions,Inc. _ ncur:ivL:u Commonwealth of Massachusetts 041Ci Of Northampton I JUL 3 1 2020 City p � PFPT. F SUILDIN9 INSPECTIONS Date: 7/28/2020 Sheet Metal Permit permit Estimated Job Cost: $60,000.00 Permit Fee: $ �j� Plans Submitted: YES NO Plans Reviewed: YES NO Business License# 824 Applicant License # SM2626 Business Information: Property Owner/Job Location Information: Name: Rock Valley HVAC (Jesse Fortier) Name: Nonotuck Mill LLC Street: 296c Nonotuck Street Street: 296 Nonotuck Street-Ma Adaptive Tech City/Town: Florence City/Town: Florence Telephone: (413) 535-7804 Telephone: (413) 737-7803 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2 / M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other V Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: V Renovation: HVAC Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Install American Standard 7.5 ton packaged unit. Install spiral duct system. Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential, $100.00 Commercial INSURANCE COVERAGE: I have a current liar insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes® No ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy ® Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee rims not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waive this requirement. Check One Only Owner ® Agent ❑ Signature of Owner or Owner's Agent By checking this box®, I hereby certify that all of the details and information 1 have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO j PrjUoreSSIncn�tinnc D-JAC Find Incnvrtinn D.Ue Type of License: By ® Master Title ❑ Master-Restricted r-- City/Town ❑Journeyperson Signature of Licensee Permit# ❑Journeyperson-Restricted SM262 License Number: Fee$ ❑ X� � Check at www macs 93v� ldpi Inspector Signature of Permit Approval Rock Valley Project Summary Date: July 27,2020 Entire House By: Rock Valley HVAC Inc. 296C NonotLK*Street,Florence,Ma 01062 Phone:(413)535-7804 Email:rockvalle^ac@yahoo.00m Web wwwroavalleytWac com License SM2626 Pro"ect Information For: Ma Adaptive Tech,Nonotuck Mill LLC 296 Nonotuck Street, Florence,Ma 01062 Notes: Desiqn Information Weather: Greenfield(Worcester Dd),MA, US Winter Design Conditions Summer Design Conditions Outside db -2 'F Outside db 85 'F Inside db 72 'F Inside db 68 'F Design TD 74 'F Design TD 17 'F Daily range M Relative humidity 50 % Moisture difference 42 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 100436 Btuh Structure 60460 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh piping 0 Btuh Equipment load 100436 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 54414 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 40550 Btuh Ducts 0 Btuh Central vent(0 chn) 0 Btuh Heating Cooling (none) Area(ft) 8710 8710 Equipment latent load 40550 Btuh Volume(ft) 78390 78390 Air changes/hour 0.37 0.19 Equipment Total Load(Sen+Lat) 94964 Btuh Equiv.AVF(cfm) 483 248 Req.total capacity at 0.70 SHR 6.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating Input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual airflow 4266 cfrn Actual airflow 4266 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.071 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.60 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pk wrightsoft 2020-Jt1-2816:29:47 Rigft-Sute®Urtversal 2019 19 0 19 RSU24598 Page 1 ACCA ...erstero\Desldop\Jobs\ATCMillkCrockerATC.rt{ Calc=MJ8 BuldingFront faces:SE