Loading...
SOLAR PLANSRELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVING JURISDICTION: BUILDING: CONTACT NAME: PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNdvancedSolarSolutions 39650Mallard BassLake,C93604 PHONE: 559-321-7000 EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSEDWRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLEALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDEDAND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJREQUIREMENTS. ASCE 7-10 WIND SPEED: MSP RATINGS COMBINER(S) AZIMUTH TILT NORTHDRIVEWY℄ EMERSONWY ⅊ ⅊ ⅊ ⅊ N/A VB 11.520 KW PV-001 COVER SHEET Bascomb, Christopher Steven Silverman 2015 National Grid 2015 22357182 2015 21134A (413) 584-8844 2020 Lilian Wanjiku (413) 584-8844 City of Northampton Info@valleysolar.solar 50507 Civil (202) 874-3483 swyssling@wysslingconsulting.com R-3 Risk Category II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook Dr Alpine, UT 84004 Bascomb, Christopher 205 Emerson Way, Northampton, MA 01062 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED WITH BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 REC REC360AA GENERAC PWRcell 7.6 APKE00014 SnapNrack Ultra Rail UR-60 Snapnrack 242-01220 L Foot INTEGRATED IN INV & OPT Generac PWRcell 17 32 1 N/A 110 N/A 1 0 (E) GPS COORDINATES : 42.309081, -72.678014 10.564 KW 5 120/240V - 1Φ 32°, 40° 228°,138° ROOF COVERING MAX ARRAY HGT. 117 N/A Comp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS 200A BUS/200A MAIN BREAKER BACK-FED BREAKER PV-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS :* PPCCDWKICC STGPPSLCTCLQPMTWLLB PVSPSCT PVYMCMP;CLGBTTLMT T,MLS,VTSSCCCT CMBSTFLSTFSPV SYSTMSCMPLCWTH4AD ALLUL,I,ICLSSFCTSS QMTS. PIDHUDW:* PVSYSTMCCTSSTLLBLG SHLLCLPIDHUDWFUCITHT CTLSSPCFCPVCCTSCCC WTH(A)-(D) QUIPMCI&CIC :* JUCIDPUBXPMTTTB STLLPVMLSCMPLCWTH 34. DDIICDICC()SHLLBPV WHTHVTSTWTHSGHTFTHC SVCGSCCT.5(A) LLQPMTSHLLBSTLLCCIB QUIFIDPCMPLC PPLCBLCS. LLCMPTSIDFHIIDD PUPDDFUDUWH PPLCBL. UCUDII :* CKIYM&PVPMUD FPSHLLBLSTLBLCCC WTHUL73SHLLBSTLLCCC WTHTHMFCTSTLLTSTCTS. LLPVCKGTTCHMTPTSSHLLTC THP-GMXPTLBYTH CKGMFCTSGFC. UDI:* IUUDDYMLYTHCCCTS GQQPMT GGCCT.LLMTLLCTCL QPMTSTCTLCMPTSBT G,CMPLCWTH534 53(A) PVQPMTCLGMDUFMDH MPHBUDDCMPLC WTH43MMMG CCTSSZCCCWTHTABL 5. CCTVPTSFMLFMS,ML CKG,CLSSSHLLBG CMPLCWTH534AD53(A). U2703PPVMDUDCKUDI SHLLBSSTLLPMFCT'S STLLTML.FUL73PPV GGSTS,MLGGLGS MSTBSTLLTTHSPCFGGLG HLSPTHMFCT'SSTLLT QMTS. HUDICCIMDUSHLLB GSCHTHTTHMVLFMLS TTPTGGCCTTTH ML. HUDICDYMCMPLSWTH 4755THGH5. FSTGSYSTMSCCSSBLQT, GGLCTSYSTMWLLBPV CMPLCWTH5,47AHJ. PVSYSTMSSHLLBPVWTHDCUD- FUPCI4(B) ICCI/PC:* D-IDICCICMPLC WTH75(B) HIFCPDIDC SHLLTCTHTMPCTYFTHBSB CLGTHCPPTCTGTHBSB CMPLCWTH75(B)()(3)(c) FDP(DID)ICCI CMPLCWTH75(B)()() THPVSYSTMBCK-FBKSHLLBSTLL THPPSTFTHBSBTSHLL LSBSZPPPTLYSP 75(B)()(3)(b) UPPYIDPICCI CMPLCWTH75(A)WTHSVC TCCCTSCMPLCWTH 34 BCKFDIBKFVTTPTSMPT FMTLFSTG75(B)(5) MICIVBCHCICUISHLLBCCT TSGLCPCCCWTHTH STLLTSTCTS DICCDCPD:* DICCIWICHWLLBCFGS THTLLGZCCTSWHSCCTS PSHLLBTHTMLSMK,“LS” (TYPCLLYTHPPTMLS) CDICCSHLLBLBL,LCKBL,F VSBLBKTYPSWTCHWTHTLHL CCSSBLTQLFTLTYPSL. CDICCSHLLB“KFBL”TYP SCCT.FT,TTM3BTT P8 DDIICDICCSHLLBPV WHTHVTSTJCTTTHTLTY CSCCT,TWHTSGHTFTHTLTYC SCCT5(A) BHPIIVDIVPVCDUCM G.THF,BTHSHLLMP WHSCCTSQCMPLCWTH 5(D) CPDIDYPPCIFIDSHLLB CMPLCWTH8,,754. BHPIIVDIVDCPVCDUC UUDD;BTHQVCT PTCTCMPLCWTH CFU(FCI)DCCICUIPCISQ FLLPVSYSTMSPTTGBLG WTHMMMSYSTMVLTGF80VLTS GT.LLCPVCCTSSTLL BLGSWLLBC-FLTCCTPTCT CMPLCWTHULBSHLLB LSTLBLCCCWTHUL(B) WII&CDUI:* CDUIDCDUCHBPPVD FTHTPPSCLGWT LCTSPSTSLGHT.CT CCTSZSPCFCTSBSTH MMMCQMTSTLMT TPSZG. CDUCHBIZDCMPLCWTH 8,7. CDUCHBDDSPPLCBLT THSPCTVVMTCLGCT SLGHTCCCWTH 35(B)(3)(4)(c) XPDUUDDDCPVUCDUPU CICUISHLLSCCTSLSTTF SPHTVLTC(PV)WCMPLC 3()().PVMLSWLSSHLLBLST FSWTHGSYSTMSCMPLC WTH4(B) PVWIBCKWIMYBFL-MKWHT CMPLCWTH(A)() PVMDUCDUCCDUDYWLL BSCWKMLKM CMPLCWTH. WPFI:* LLWFPPISHLLBSL MWTHTGHTWTHPPVCHMCL SLTFLSHGSWHQPC GLBLGFGWKMSHP STSBYLCSCTCT. LLXICICQUIPM,HBM 3BTTT.LLTCT CCTSSHLLBTFWTLCTS. *LLTSSPPLCBLTTHSPJCT. SGYTSTHTTPPLYTTHS PJCT.N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPN2015 IFC ROOF ACCESS REQUIREMENTS PV SITE LAYOUT LEGEND * EXISTING DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH NDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 R R NORTH SECTION 1 SECTION 4 SECTION 2 SECTION 3 DRIVEWY THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP.SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. . B. C. PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/8''=1'-0" @ SHEET SIZE A3 2054 SECTION-1 169 29.36% 228 32°SECTION-1 138 32°SECTION-4 228 40°SECTION-2 SECTION-3 228 40° 151 SECTION-4 254 38SECTION-2 SECTION-3 QTY 32 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESS* EXISTING ROOF DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RILTOROOF ATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURAL CONSTRUCTION ROOFING COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING * DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO ROOF RACKING RAIL NORTH20'-014"8'-8" 5'-112"5'-734"26'-0"16'-734"16'-1114"10'-3" B. ANCHOR SPACING SHOWN IN DETAIL. UNLESS NOTEDOTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS. SEE "TABLE OF DIMENSIONS" EACH SECTION DETAILED FOR HORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENT MANUFACTURERS. SCALE:1/8''=1'-0" @ SHEET SIZE A3 Pre-Eng Roof Trusses 24" O.C. 2"x 4" @ 24" MAX OC Comp Shingle 3.17 PSF QTY 32 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 10:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 4’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP 21SCALE: NTS 3 4 .THESE NOTES APPLY TO PRE-ENGINEERED PLATED TRUSSES. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODE REQUIREMENTS AT THE TIME IT WAS BUILT. C. STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING IS ACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL HAVE NO MORE THAN TWO LAYERS. (SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUT SIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES. STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS H1 PV MODULE HGT. ABOVE ROOF RISE ROOF PITCH OH1 OVERHANG IN THIS AREA UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS H1 PV MODULE HGT. ABOVE ROOF RISE ROOF PITCH OH1 OVERHANG IN THIS AREA UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSPER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER MAX RAFTER SPAN MAX RAFTER SPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOF CONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILS ARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FOR DESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTED BY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL 1 5 6 7 RISE 12 PRE-ENGINEERED FRAMING @ APPROX. 24" O.C. 2 OH1 PV 1 D1H1 D3 D2 D2 * IF BLOCKING REQUIRED32 S-201 1 S-201 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. D3 12 RISE 5 6 8 1 7 3 PV 1 D1H1 OH1 D2 D1 D3 D2 * IF BLOCKING REQUIRED32 S-201 1 S-201 D2 24" MINWHEN NOTSTAGGERED. TYP PRE-ENGINEERED FRAMING @ APPROX. 24" O.C. ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 (E) FRAMING @ ASSUMED 24" O.C. TYPICAL 2'-0" TYP. 4'-0" MAX 25' Comp Shingle MANUF TRUSS / TRUSS - PORTRAIT MANUF TRUSS / TRUSS - LANDSCAPE STANCHION DETAIL STANCHION SPACING DETAIL 12" 40°, 32°3" - 6" TYP 16.94" 33.88" 34.12" Ultra Rail UR-60 242-01220 L Foot L-Foot Flashing 12" 40°, 32°3" - 6" TYP 10" 20" 20.25" NOT USED ENGINEERED TRUSS ENGINEERED TRUSS S-200Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND * DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATION INSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE: NTS 3 4 SCALE: NTS SCALE: NTSSCALE: NTS ATTACHMENT DETAILSROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSROOF RACKING RAIL ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" EMBEDMENT INTO FRAMING MEMBERS (E) ROOF SHEATHING /DECKING (E) FRAMING MEMBER L-FOOT PV MODULE, BY OTHERS MODULE END CLAMP SNAPNRACK ULTRA RAIL SNAPNRACK COMP UMBRELLA FLASHINGS5/16”-18X2-1/4” SS HCS BOLT 1/3" OF TOTAL SPAN MAX 2/3" OF TOTAL SPAN MAX RAIL MANUFACTURER RAIL SPLICE KIT SEE "S-100 / TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE. SEE SHEET "S-100" FOR: HORIZONTAL ANCHOR SPAN SPACING. (E) FRAMING TYPICAL * MODULES SHOWN PORTRAIT IN EXAMPLE DC AND/OR 1/3 CANT. MAX COMPONENT + 2" FROM SIDE OF MODULE 2" ROOF TOP CONDUIT EXTENSION OF RAIL RAIL OR STRUT CONNECTIONS TO MEET WEIGHT REQ. OF EQUIPMENT DCB * MODULES SHOWN PORTRAIT IN EXAMPLE ** RAILING SHOWING IN VERTICAL IN EXAMPLE STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL NOT USED S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STC TEMPERATURE CORRECTED TEMPERTURE MFR. PMAX TEMP COEFFICIENT [-0.#%/C] * 100 FORMULA CORRECTED TEMP. COEFFICIENT MODULE Voc [VDC] TEMPERATURE CORRECTED OPEN CIRCUIT VOLTAGE - =*= +*=EQUIP. CALCULATIONSPV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/ PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (OPERATING CURRENT)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC DC/DC OPTIMIZER (IF APPL.) MANUFACTURER MODEL NUMBER WEIGHT Ibs RATED OUTPUT isc AMPS MAX OUTPUT VOLTAGE VOLTS MAX INPUT VOLTAGE Voc VOLTS DC COMBINER / DISCONNECT #1 MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPS DC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS STRING INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17 INTEGRATED AC DISCONNECT AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) ADDRESSTHICK WATTSMAX. AC APPARENT POWER kW PHOTOVOLTAIC PLANSDC COMBINER / DISCONNECT #2 (IF APPL.) MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS QTY MAX PV MODULE Voc VOLTS DC MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE VOLTS DC MAX INPUT FUSE/BREAKER RATING AMPS DC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT AMPS AMPS MANUFACTURER MODEL NUMBER OCPD (DISCONNECT TYPE) WEIGHT Ibs NEMA RATING LOCATION OF COMPONENT DC INPUT QTY MAX PV MODULE Voc MAX # OF MODULES IN CIRCUIT QTY MAX ALLOWED INPUT VOLTAGE AMPS DC OUTPUT MAX CIRCUIT OUTPUT CURRENT AMPS MAX CONT. OUTPUT CURRENT SERIES FUSE RATING FOR PV MODULES AMPS (OCPD) QUANTITY OF PV SOURCE CIRCUITS VOLTS DC VOLTS DC MAX INPUT FUSE/BREAKER RATING DC COMBINER / DISCONNECT #3 (IF APPL.) QUANTITY STRING INVERTER #2 SPECIFICATIONS (IF APPL.) AMPS - MAX MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max INPUT DC VOLTAGE VOLTS DC Min. MPPT VOLTAGE RANGE VOLTS DC Max. MPPT VOLTAGE RANGE VOLTS DC Max INPUT CURRENT AMPS MPPT QTY INTEGRATED DC DISCONNECT COMPLY W/NEC 690.17 INTEGRATED AC DISCONNECT AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT WATTSMAX. AC APPARENT POWER QUANTITY INVERTER(S) INVERTER(S) AC COMBINER #1 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 AMPS (Imax) AMPS (Imax) AC COMBINER #2 (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AMPS (Imax) AMPS (Imax) AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS AMPS (Imax) MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #3 PV BACKFEED BREAKER #4 ALT. ENERGY BACKFEED BREAKER (IF APPL.) SUM OF EXISTING CIRCUIT BREAKERS PCIFICION Years/MWh10/7.56Modulesion - Warranty:i Years10:ElectronicsWarranty U9540,U1973,U1642 -22.2 ompliance -EbusDanogridommunicationProtocol (kg)b,l(202)445,eight(Installed)W (kg)b,l(52)15,1eight(Enclosure)W (kg)b,l55,(25)ionmodule) - Weight(i VD46.8ModuleVoltage -6BatteryModules (mm)n,Ix22x10(1725x560x235)68Dimensions mt,f(3000)9834,MaximumInstallationltitude )F,()30 - 86,(13 - 54ecommendedTemp.ange ),(F45)-(5113,-41ngeperatingTemp.a %96.5TripEfficiency-ound VD420-360EbusVoltage:Input/utput kW10utesPower:2min kW8.4Power:60minutes kW6.7Power:atedontinuous kWh17.1UsableEnergy snit Specification - REC Eaton DG222URB 1 REC360AA 43 67.75 x 40 x 1.18 NON-FUSIBLE DISCONNECT 120/240360 43.9 36.7 10.49 60 48.73 9.82 3R 2 N/A 32-0.24 20.0 Generac PV Link APKE00010 7.3 8 420 420 GENERAC PWRcell 7.6 APKE00014 7600 62.7 420 420 360 20 2 Yes NO 240 7600 40 32 -20 25 -45 -0.24%0.11 1 1.11 43.9 48.73 1 E-001EXISTING 120/240V Single Phase 200 200 0 40 40 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUIT CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILL DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMP RATING TRADE SIZE AMPACITY PER 310.16 MAX CURRENT 690.8 (A)(1) CONT. OPERATION 690.8 (B)(1) REQUIRED AMPACITY CIRCUIT ENVIRONMENT MBIENT TEMP. HGT. ABOVE ROOF (in) TEMP. ADDER PER 310.15 (B)(2)(c) OPERAT. TEMP. AMPACITY CORRECTION 310.15 (B)(2)(a) # OF UNGRND. COND. AMPACITY CORRECTION 310.15 (B)(3)(a) COND. AMPACITY TEMP. DERATING CONDUIT FILL DERATING XXX=XX=CORRECTED AMPACITY REQUIRED AMPACITY <CORRECTED AMPACITY DC1 XXX=XX=< DC2 XXX=XX=< DC3 XXX=XX=< DC4 XXX=XX=< DC5 XXX=XX=< AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUIT DESTINATION CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILL DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMP RATING TRADE SIZE AMPACITY PER 310.16 CONT. OPERATION 690.8 (B)(1) X =REQUIRED AMPACITY CIRCUIT ENVIRONMENT MBIENT TEMP. HGT. ABOVE ROOF (in) TEMP. ADDER PER 310.15 (B)(2)(c) OPERAT. AMPACITY CORRECTION 310.15 (B)(2)(a) # OF UNGRND. COND. AMPACITY CORRECTION 310.15 (B)(3)(a) COND. AMPACITY X TEMP. DERATING X CONDUIT FILL DERATING =CORRECTED AMPACITY REQUIRED AMPACITY <CORRECTED AMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X =WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED. 3. 4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. WHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED. WIRE COLOR CODING (2020) CEC /NEC SECTIONS 250.119 & 200.6 PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT ARE EQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED CONDUCTOR(S). TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES APN ADDRESS kW PHOTOVOLTAIC PLANSAC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < DC6 XXX=XX=< DC7 XXX=XX=< DC8 XXX=XX=< #OF COMBINED PARALLEL STRINGS DESTINATION QTY IN PARALLEL &MATERIAL QTY IN PARALLEL &MATERIAL lsc (AMPS) OR COMPONENT (AMPS) MAX INV. OUTPUT CURRENT (AMPS) OR COMPONENT (AMPS)E-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMITPV MODULE PV LINK (1) CU 90 #12 AWG 30 10.49 1 1.25 1.25 16.39 ROOFTOP 35 0.5" – 3.5"22 57 0.71 2 N/A 30 0.71 1.0 21.3 16.39 21.3 PV LINK Y-CONNECTOR (1) CU 90 #10 AWG 40 8 1 1 1.25 10 ROOFTOP 35 0.5" – 3.5"22 57 0.71 10 N/A 40 0.71 1.0 28.4 10 28.4 Y-CONNECTOR JUNCTION BOX (1) CU 90 #10 AWG 40 24 1 1 1.25 30 ROOFTOP 35 0.5" – 3.5"0 35 0.96 4 N/A 40 0.96 1.0 38.4 30 38.4 JUNCTION BOX INVERTER (1) CU 90 #10 AWG 40 24 1 1 1.25 30 EXT WALL 35 N/A 0 35 0.96 4 0.8 40 0.96 0.8 30.7 30 30.7 BATTERY INVERTER (1) CU 90 #10 AWG 40 24 1 1 1.25 30 EXT WALL 35 N/A 0 35 0.96 2 1.0 40 0.96 1.0 38.4 30 38.4 47.0 0.94 0.94 0.94 0 0 0 N/A N/A N/A N/A 0 0.94 40.0 50.0 47.0 61.1 1.0 1.0 0.94 0.94651.033535EXT WALL50.050 (1) CUAUTO TRANSFER SWITCH EXT WALL INVERTER AC DISCONNECT (1) CU 75 #8 AWG 50 1.25 32 40.0 EXT WALL 35 35 3 1.0 50 0.94 1.0 47.0 40.0 AC DISCONNECT PRODUCTION METER (1) CU 75 #8 AWG 50 1.25 32 40.0 EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 40.0 47.0 PRODUCTION METER EXISTING SERVICE PANEL (1) CU 75 #8 AWG 50 1.25 32 40.0 EXT WALL 35 35 3 1.0 50 47.0 INVERTER AUTO TRANSFER SWITCH (1) CU 75 #6 AWG 65 N/A 61.1 CRITICAL LOADS PANEL 75 #6 AWG 65 N/A 50 50.0 35 35 3 1.0 65 0.94 1.0 61.1 50.0 61.1 0.940N/A(1) CUAUTO TRANSFER SWITCH EXT WALLEXISTING SERVICE PANEL 75 #6 AWG 65 N/A 50 50.0 35 35 3 1.0 65 0.94 1.0 61.1 50.0 61.1 LEGEND RELEASEREVDATE NAME ADDRESSTHREE LINE DIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 3 DC DISCONNECT 4 DC MODULE LEVEL RSD 5 JUNCTION BOX 6 RAPID SHUTDOWN 7 AC/DC INVERTER 8 AC/DC INVERTER W/ INTE AC DISC 9 BATTERY 10 11 PROD/GEN METER 12 13 14 15 EXISTING UTILITY METER NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED TAG APN ADDRESSSEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS kW PHOTOVOLTAIC PLANSELECTRICAL NOTES UNGROUNDED PV SYSTEMS: •INVERTERS, MODULES, AND DC COMPONENTS MUST BE LISTED FOR USE IN UNGROUNDED SYSTEMS, TYPICALLY TRANSFORMER-LESS (TL) •OCPD'S WHERE NECESSARY MUST HAVE DISCONNECTING MEANS. •PV SOURCE CIRCUITS MUST BE EITHER PV WIRE AND LISTED FOR WET LOCATIONS OR JACKETED MULTI-CONDUCTOR CABLES INSTALLED IN RACEWAY. •THE AC SIDE IS STILL GROUNDED ON THE NEUTRAL CONDUCTOR. •REQUIRE EQUIPMENT GROUNDING BUT DOES NOT HAVE SYSTEM GROUNDING; NO DC CURRENT-CARRYING CONDUCTOR IS CONNECTED TO GROUND. THESE CONDUCTORS ARE COLOR CODED DIFFERENTLY THAN GROUNDED PV SYSTEMS. AC/DC ELECTRICAL NOTES: •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BE RATED FOR 600 VOLTS ON THE DC / PV POWER SIDE OF THE INVERTER. •EXTERIOR ENCLOSURES TO BE NEMA TYPE 3R OR BETTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FOR WET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND STRING MODULE QTY INVERTER# BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 DC2 DC3 DC4 DC5 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE CONDUIT TABLE AC6 AC7 AC8 AC9 AC10 DC6 DC7 DC8 16 AC DISCONNECT (INDEPENDENT) • * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS 1 1 1 1 1 1 1 1 1 1 EGC M 16 G N BUS RATING 200A 15 MAIN C/B RATING 200A AC1 AC3 GEC G AC G N G L2 L1 3 6 DC GNL2L1 GNL2L1 N G L2 L1 PWRCell - + DC5 INVERTER NAMEPLATE RATING 7600W /240V CONFIGURED AS MAIN OCPD SHALL BE IN COMPLIANCE WITH NEC 408.36(D) 13 DC1 DC1 DC1 DC1 DC1 G G EGC DC3 DC4 5 7 MODULES 6 MODULES 6 MODULES 6 MODULES 7 MODULES MODULE NAMEPLATERATING 360WMC-4 Y-CONNECTORS 7 AC2 AUTO TRANSFER SWITCH L1 L2 N L1 L2 N G L1 L2 N G 10 AC4 G N G 50ADC2 AC5 AC6 50A 12 LOCATED EXTERIOR SOLAR GENERATION (LOAD) BOTTOM LUGS TO TOP LUGS TO UTILITY (LINE) NATIONAL GENERATION METER 4 4 4 4 4 4 4 4 4 4 2 2 2 2 2 40A N G L2 L1 PV N G L2 L1 11 L2 L1 L2 L1 GG NN 9 READILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT VISIBLE FROM APPROACH TO RESIDENCE 60A 240V LOCATED EXTERIOR ON WALL NEAR METER NEMA 3R AUTO TRANSFER SWITCH CIICOP00ABUS/0AMB NOTE: CONDUCTORS AC1, AC2, AC3, AC4, AC5 & AC6 MAY BE THWN-2 OR SER CABLE •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FOR BACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS, UNLESS OTHERWISE MARKED, ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINE TBEPERMITTEFRBCKFEERREVERECURRET •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITY INTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) 32 REC REC360AA 5 PV Link APKE00010 N/A INTEGRATED IN INV 32 SnapRS Device 4 Soladeck RSTC 0799-5B N/A INTEGRATED IN INV & OPT 1 GENERAC PWRcell 7.6 APKE00014 0 1 19 Eaton DG222URB INV 1 RSXW200A3 2 13 INV 1 1 1 1 1 0 1 1 120/240V - 1Φ 40A 1 NEW MAIN SERVICE PANEL EXISTING MAIN SERVICE PANEL 200A BUS/200A MB Genrac PWRcell 17 Battery NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER CEC/NEC 705.12(B)(2)(3)(b)E-003DC/DC OPTIMIZER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT2 #12 AWG PV Wire #6 AWG N/A Open Air 11 #10 AWG PV Wire #6 AWG N/A Open Air 5 #10 AWG THWN-2 #8 AWG N/A Open Air 5 #10 AWG THWN-2 #8 AWG 3/4 inch EMT 3 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT NATIONAL GRID/MA SMART METER 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMTThe battery will only be charged by PVThe battery will only be discharged to on-site loadsIf requested by the grid via connected solutions,the battery can discharge to the grid. RELEASEREVDATE NAME ADDRESSAPNELECTRICAL SYMBOL LEGEND AC DISCONNECT DC DISCONNECT DC COMBINER BOX AUTO TRANSFER SWITCHCB DC AC ATS DCB DC DISCONNECTING COMBINER BOX ELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES MUST BE CONNECTED TO THE EGC (EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPS OR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBS ARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKING SPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2. FOR "LAY-IN" LUG MODULE GROUNDING; CORRECT HARDWARE OF PROPER METAL MATERIAL TO AVOID CORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED, TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BE ATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TO BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSED METAL PARTS THAT MIGHT COME INTO CONTACT WITH CURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THE METAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS, DISCONNECTS, METERS, JUNCTION BOXES AND COMBINER BOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTS TO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THE CONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THE SYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT, OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECT CONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING, USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BE DUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP ADDRESS kW PHOTOVOLTAIC PLANSSOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATT INV#DC/AC STRING INVERTER CLP CRITICAL LOADS PANEL SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP PERFORMANCE METER UTILITY METER P M XFMR TRANSFORMER JUNCTION BOXJB RSD RAPID SHUTDOWN SUB-PANELSUBINV1CSPMTSCLPPBTTNORTH JB JB JB JB SCALE:1/8''=1'-0" @ SHEET SIZE A3QTY 32 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER E-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSHEET NOTES1SCALE: 1/2" = 1'-0"CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 2 3 5 6 7 SCALE: 1/4" = 1'-0"8 9 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12" FROM BENDS, 12" ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE: NEC 690.31(G)(3) 3.MINIMUM OF 1 1/8" x 5 3/4" 4.FONT: 3/8" AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX, DC COMBINER, AND DC DISCONNECT WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SCALE: 1/4" = 1'-0" 1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITS OR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSED DURING SERVICE. 3.CODE REFERENCE:NEC 690.35(F) 4.MINIMUM OF 3" x 10 1/2" 5.FONT: 3/8" 6.WHITE LETTERS ON A RED BACKGROUND. NON-LOAD BREAK DC COMBINER / J-BOX WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SCALE: 1/2" = 1'-0" 1.PLACED ON DC DISCONNECT(S) AND ON ANY EQUIPMENT THAT STAYS ENERGIZED IN THE OFF POSITION FROM THE PV SUPPLY. 2.CODE REFERENCE: NEC 690.17(E) 3.MINIMUM OF 3 1/2" x 10" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. INVERTER(S)SCALE: 1/2" = 1'-0" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 1.NORMALLY ALREADY PRESENT ON LISTED INVERTERS 2.CODE REFERENCE: NEC 690.5(C) 3.MINIMUM OF 3 1/2" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. AC AND DC DISCONNECTS PHOTOVOLTAIC SYSTEM DISCONNECT 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE: NEC 690.14(C)(2) 3.MINIMUM OF 1" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" DC COMBINER BOX 1.CODE REFERENCE: NEC 690.16(B) AND NEC 690.17 2.USE PLACARD "COMBINER # 1" WHEN MORE THAN 1 DC COMBINER IS USED. NUMBER ACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .75 TO .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. 1.CODE REFERENCE: NEC 690.16(B) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1" x 6" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1.USE PLACARD ON CUSTOMER GENERATION METER. 2.VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. SOLAR kWh METER SCALE: 1/2" = 1'-0" INVERTER # 1 1.USE PLACARD "INVERTER # 1" WHEN MORE THAN 1 INVERTER IS USED. NUMBER ACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1" x 4" 3.FONT: 3/8" 4.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2" = 1'-0"INVERTER'S USE PLACARD "[AC][DC] DISCONNECT # 1" WHEN MORE THAN ONE DISCONNECT IS USED. NUMBER ACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 10 SCALE: 1/4" = 1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE PLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN PLACE OF THE STANDARD WHITE LETTERS WITH RED BACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (IFC 605.11.1, NEC 690.31[E][3], NEC 690.31[E][4], 690.17 & 690.53) 4.THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. (IFC 605.11.1.4, NEC 690.31[E][3] & NEC 690.31[E][4]) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT, NON-BOLD. 7.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 7.4.CONTRASTING BACKGROUND AND LETTERING. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVED MANUFACTURED PRODUCT STANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSCODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL) 90.5()(1)(a 3/8"BACKCHARACRSOYELLOW BACKGROUD,RAGCHARACRS3/16" BACKOWHBACKGROUD LATMTHA1mFROHSRVCDSCO MASTWHIHTHPVSYSTMSATA SHALLIIATTHLATIALLITIIAPI SHUTWSWITHSITATTHSAMLATI. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS P-001QTY 32 REC REC360AA MODULES QTY 1 GENERAC PWRcell 7.6 APKE00014 INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSHEET NOTES 1. 2. 3. 4. COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE PLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROM THE MULTIPLE PLACARDS MUST BE PRESENT. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN PLACE OF THE STANDARD WHITE LETTERS WITH RED BACKGROUND WITH AHJ APPROVAL. ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (IFC 605.11.1, NEC 690.31[E][3], NEC 690.31[E][4], 690.17 & 690.53) REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING. UL LISTING OF MARKINGS IS NOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT, NON-BOLD. 5.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 5.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS. 5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVED MANUFACTURED PRODUCT 6.ANSI Z535.4-2014 PRODUCT SAFETY SIGNS AND LABELS: THIS INFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDS MAY BE USED WITH PRIOR APPROVAL OF THE AHJ.MOST NOTABLE DIFFERENCES IS COLOR OF PLACARDS AND USEOF HAND WRITTEN VALUES WITH INDUSTRIAL MARKERS ON STANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT A FUTURE DATE. I.E. ADDING MODULES AT A FUTURE DATE, OR STANDARD PLACARD MANUFACTURER INSTALLED ON ELECTRICAL COMPONENT. AHJ APPROVAL REQUIRED. (SEE NOTE #1 FOR INDIVIDUAL PLACARDS) 1 SCALE: 1/4" = 1'-0"2 3 4 1.PLACARD PLACED ON EACH DISCONNECT, IF MORE THAN ONE PRESENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / DC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.53 4.MINIMUM OF 2 1/2" x 8" OR 5" x 2 1/2" RESPECTIVELY. 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. 7.IN SOME CASES TWO LABELS MAY BE REQUIRED. AN INVERTER WITHINTEGRATED DC DISCONNECT UTILIZING TWO MPPT TRACKERS; IF CONFIGURATIONUSES DIFFERENT MODULES. SCALE: 1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE: 1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE PV SYSTEM DC DISCONNECT ADC PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDC 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / AC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.54 4.MINIMUM OF 1 1/2" x 8 1/2" OR 1 3/4" x 6 1/2" RESPECTIVELY. 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1) PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEM SUPPLY BREAKER AT POINT OF INTERCONNECTION. (#2 & #3) PLACARD(S) REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT(S) ARE NOT LOCATED NEXT TO EACH OTHER. MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS. IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS; SEE SHEET "E-001 / STRING INVERTER[#] SPECIFICATIONS". 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. 2.1.2."RATED AC OUTPUT CURRENT" WILL BE THE SUM OF THE INVERTERS 2.1.3."AC NORMAL OPERATING VOLTAGE" WILL BE THE NAME PLATE RATING OF THE INVERTER 3.CODE REFERENCE: NEC 690.54, NEC 705.12(D)(3) 4.MINIMUM OF 2" x 6 1/2" (#1), VARIES (#2 & #3) 5.FONT: 3/8" HEADER, 3/16" DATA (#1), 1/4" (#2 & #3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE: 1/2" = 1'-0" CAUTION DC DISCONNECTS & DISCO. COMBINER DYNAMIC PLACARDS(WITH COMBINED WARNING PLACARD IF REQUIRED. EXAMPLE: LADWP) PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT PV SYSTEM DC DISCONNECT PHOTOVOLTAIC SYSTEM DC DISCONNECT #1 #2 #3 RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING STRING INVERTER #1 - INTEGRATED AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS STRING INVERTER #2 - INTEGRATED AC DISCONNECT AC DISCONNECT #1 - INDEPENDENT/ SEPARATE AC SUB-PANEL #1 ADDRESS kW PHOTOVOLTAIC PLANS#1 #2 #3 CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL)VDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC MAXIMUM CIRCUIT CURRENT MAXIMUM VOLTAGE ADC MAX. CIRCUIT CURRENT MAXIMUM VOLTAGE ADC VDCVDC N N PRODUCTION METER CDISCO (E)UTILITYMETER &SERVICEPNEL INVERTER W/DCDISCO TUOTRNSFORMER SWITCH SOLARARRAY ONROOFTOP PRODUCTION METER CDISCO (E)UTILITYMETER &SERVICEPNEL INVERTER W/DCDISCO UTOTRNSFORMER SWITCH SOLARARRAY ONROOFTOP TTISVINT THVINVTNVISONNTSIFNOTT THSMOTION MOVISITOYOFTH SVIISONNTINGMNSN HOTOVOTISYSTMISONNTIONMNS OFN:N69056()(B),7050 WHITTTSONBKGOUN MINIMUMOF6/2"x6/2" FONT:3/4""UTION",/4"H,/8"T NNOTS WIBJNTTOTHMIN SVIISONNTINOTIONY VISIBFOMWHTHISONNTIS OT(IF6053) TTISVINTTHV INVTNVISONNTSIFNOTTTHSMOTION 2 MOVISITOYOFTHSVI ISONNTINGMNSNHOTOVOTISYSTM ISONNTIONMNS 3 OFN:N69056()(B),7050 4 WHITTTSONBKGOUN 5 MINIMUMOF73/4"x5" 6 FONT:3/4""UTION",/4""WNING",3/6"H, /8"TNNOTS 7WIBJNTTOTHMINSVI ISONNTINOTIONYVISIBFOMWH THISONNTISOT(IF6053) CRITICL LODPOINT BTTERY CRITICLLOD POINT BTTERY 32.0240240 32.026.2 26.2 240341341 32 240 32.0 32 240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT rec Alph α Series αexperience performance 380 wp Power ELIGIBLE FOR www.recgroup.com 28 [1.1] 1721±2.5 [67.75 ±0.1] 802 [31.5]455 [17.9] 95 6 [ 3 7 . 6 4 ] 10 1 6 ± 2 . 5 [ 4 0 ± 0 . 1 ] 17 [ 0 . 7 ] 45 [1.5] 1000 [39] 1200 [47] 11±0.2 [0.43 ±0.8]6.6 ± 0 . 2 [ 0 . 2 6 ± 0 . 0 8 ] 20.5±0.5 [0.78 ±0.08] 30 [1.18] 22.5 [0.9] 621 ±3 [24.5 ±0.12] GR GR GR Re : P M DS - 1 2 - 0 1 - Re v D 03 . 2 0 Sp e c i i c a i o n s s u b j e c o c h a n g e w i h o u n o i c e . CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS * MAXIMUM RATINGS Measuremens in mm [in] 100 200 300 400 500 600 700 800 900 1000 85 90 95 100 Irradiance (W/m²) Typical low irradiance perormance o module a STC: REC ALPHA SERIES PRODUCT DATASHEET Re l . E f c i e n c y ( % ) Nominal Module Operaing Temperaure:44°C (±2°C Temperaure coecien o P MAX :-0.26 %/°C Temperaure coecien o V OC :-0.24 %/°C Temperaure coecien o ISC:0.04 %/°C * The emperaure coeciens saed are linear values Operaional emperaure:-40 ... +85°C Maximum sysem volage:1000 V Design load (+: snow Maximum es load (+: 4666 Pa (97.5 lbs/sq + 7000 Pa (146 lbs/sq * Design load (: wind Maximum es load (: 2666 Pa (55.6 lbs/sq + 4000 Pa (83.5 lbs/sq * Max series use raing:25 A Max reverse curren:25 A + Calculaed using a saey acor o 1.5 * See insallaion manual or mouning insrucions Founded in Norway in 1996, REC is a leading verically inegraed solar energy company. Through inegraed manuacuring rom silicon o waers, cells, highqualiy panels and exending o solar soluions, REC provides he world wih a reliable source o clean energy. REC’s renowned produc qualiy is suppored by he lowes warrany claims rae in he indusry. REC is a Bluesar Elkem company wih headquarers in Norway and operaional headquarers in Singapore. REC employs around 2,000 people worldwide, producing 1.5 GW o solar panels annually. IEC 61215:2016, IEC 61730:2016, UL 1703, UL 61730 IEC 62804 PID IEC 61701 Sal Mis IEC 62716 Ammonia Resisance UL 1703 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailsone (35mm AS4040.2 NCC 2016 Cyclic Wind Load ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 Standard REC ProTrust Insalled by an REC Ceried Solar Proessional No Yes Yes Sysem Size All ≤25 kW 25-500 kW Produc Warrany (yrs20 25 25 Power Warrany (yrs25 25 25 Labor Warrany (yrs0 25 10 Power in Year 1 98%98%98% Annual Degradaion 0.25%0.25%0.25% Power in Year 25 92%92%92% See warrany documens or deails. Condiions apply. ELECTRICAL DATA Product Code * : RECxxxAA Power Oupu P MAX (Wp 360 365 370 375 380 Wat Class Soring (W-0/+5 -0/+5 -0/+5 -0/+5 -0/+5 Nominal Power Volage V MPP (V 36.7 37.1 37.4 37.8 38.1 Nominal Power Curren I MPP (A 9.82 9.85 9.9 9.94 9.98 Open Circui Volage V OC (V 43.9 44 44.1 44.2 44.3 Shor Circui Curren I SC (A 10.49 10.52 10.55 10.58 10.61 Power Densiy (W/sq 19.15 19.41 19.68 19.94 20.21 Panel Eciency (% 20.6 20.9 21.2 21.4 21.7 Power Oupu P MAX (Wp274 278 282 286 289 Nominal Power Volage VMPP (V 34.6 35.0 35.2 35.6 35.9 Nominal Power Curren I MPP (A 7.93 7.96 8.00 8.03 8.06 Open Circui Volage V OC (V 41.4 41.5 41.6 41.6 41.7 Shor Circui Curren I SC (A 8.47 8.50 8.52 8.55 8.57 Values a sandard es condiions (STC: air mass AM 1.5, irradiance 10.75 W/sq (1000 W/m², emperaure 77°F (25°C, based on a producion spread wih a olerance o P MAX , V OC & I SC ±3 wihin one wat class. Nominal module operaing emperaure (NMOT: air mass AM 1.5, irradiance 800 W/m², emperaure 68°F (20°C, windspeed 3.3 /s (1 m/s. * Where xxx indicaes he nominal power class (P MAX a STC above. GENERAL DATA Cell ype: 120 halcu cells wih REC heerojuncion cell echnology 6 srings o 20 cells in series Glass: 0.13 in (3.2 mm solar glass wih anirefecion surace reamen Backshee: Highly resisan polymeric consrucion Frame:Anodized aluminum (black Juncion box: 3par, 3 bypass diodes, IP67 raed in accordance wih IEC 62790 Connecors: Säubli MC4 PV-KBT4/KST4, 12 AWG (4 mm² in accordance wih IEC 62852 IP68 only when conneced Cable: 12 AWG (4 mm²) PV wire, 39 + 47 in (1 + 1.2 m accordance wih EN 50618 Dimensions: 67.8 x 40 x 1.2 in (1721 x 1016 x 30 mm 18.8 sq (1.75 m² Weigh:43 lbs (19.5 kg Origin:Made in Singapore STC NMOT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSPV MODULE CUT SHEET R-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1-888-GENERAC (1-888-436-3722) 7.6kW 1Ø, 11.4kW 3Ø PWRcell Inverter w/ CTs and CT Adapter Model: APKE00014, APKE00013 Solar-plus-storage is simple with the Generac PWRcell Inverter. This bi-directional, REbus™- powered inverter oers a simple, ecient design or integrating smart batteries with solar. Ideal or sel-supply, backup power, zero-export and energy cost management, the PWRcell inverter is the industry’s most eature-rich line o inverters, available in single-phase and thr ee-phase models. ADDITIONAL FEATURES • Single inverter or grid-tied solar with smart battery integration • Simplifed system design: No autotransormer or battery inverter needed • User-selectable modes or backup power, sel-supply, time-o-use and zero-export • Free system monitoring included via PWRview Web Portal and Mobile App FEATURES: No autotransormer or battery inverter needed User-selectable modes Free system monitoring AC OUTPUT/ GRID-TIE MODEL APKE00014 MODEL APKE00013 RATED AC POWER OUTPUT 7600 W 11400 W AC OUTPUT VOLTAGE 120/240, 1Ø VAC 120/208, 3Ø VAC AC FREQUENCY 60 Hz 60 Hz MAXIMUM CONTINUOUS OUTPUT CURRENT 32 A, RMS 32 A, RMS GROUND-FAULT ISOLATION DETECTION Included Included CHARGE BATTERY FROM AC Yes Yes THD (CURRENT)< 2 %< 2 % TYPICAL NIGHTTIME POWER CONSUMPTION < 7 W < 7 W AC OUTPUT/ BACKUP MODEL APKE00014 MODEL APKE00013 RATED AC BACKUP POWER OUTPUT 8000 W 8000 W MAXIMUM AC BACKUP POWER OUTPUT 10000 W 10000 W AC BACKUP OUTPUT VOLTAGE 120/240, 1Ø VAC 120/240, 1Ø VAC AC FREQUENCY 60 HZ 60 HZ AC CIRCUIT BREAKER 50 A 50 A THD (VOLTAGE)< 2 %< 2 % AUTOMATIC SWITCHOVER TIME < 1 Seconds < 1 Seconds TYPICAL NIGHTTIME POWER CONSUMPTION 30 W 30 W DC INPUT MODEL APKE00014 MODEL APKE00013 DC INPUT VOLTAGE RANGE 360-420 VDC 360-420 VDC NOMINAL DC BUS VOLTAGE 380 VDC 380 VDC MAX INPUT CURRENT 20 A 30 A REVERSE-POLARITY PROTECTION YES YES GROUND-FAULT ISOLATION DETECTION YES YES TRANSFORMERLESS, UNGROUNDED YES YES DC INPUT/ BATTERY MODEL APKE00014 MODEL APKE00013 MAXIMUM CONTINUOUS POWER 8000 W 8000 W INTERNAL DC DISTRIBUTION BREAKERS 4X 2P30A 4X 2P30A DC FUSES ON PLUS AND MINUS 40 A 40 A 2-POLE DISCONNECTION YES YES EFFICIENCY MODEL APKE00014 MODEL APKE00013 PEAK EFFICIENCY 97 %98 % CEC WEIGHTED EFFICIENCY 96.5 %97.5 % Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com 1-888-GENERAC (1-888-436-3722) Specifcations Specifcations subject to change without notice. FEATURES AND MODES ISLANDING3 Yes GRID SELL Yes SELF CONSUMPTION Yes PRIORITIZED CHARGING FROM RENEWABLES Yes GRID SUPPORT - ZERO EXPORT Yes ADDITIONAL FEATURES SUPPORTED COMMUNICATION INTERFACES CANbus, RS4854, Ethernet SYSTEM MONITORING PWRview Web Portal and Mobile App CRITICAL LOADS DISCONNECT3 Yes MANUAL INVERTER BYPASS SWITCH Automatic WARRANTY 10 Years STANDARDS COMPLIANCE SAFETY UL1741 SA, CSA 22.2 GRID CONNECTION STANDARDS IEEE1547, Rule 21, Rule 14H EMISSIONS FCC part15 class B DIMENSIONS AND INSTALLATION SPECIFICATIONS WIRE GAUGE RANGE 10 8 AWG TOTAL AC KNOCKOUTS X SIZE 2“ x 0.75“, 2 x 1“ TOTAL DC KNOCKOUTS X SIZE 5“ x 1“ DIMENSIONS (L,W,H)24.5“ x 19.25“ x 8“ WEIGHT 62.7 lb COOLING Forced convection NOISE < 40 dBA OPERATING TEMPERATURE 20 to 50 °C* PROTECTION RATING NEMA 3R INSTALLATION GUIDELINES BATTERY TYPES SUPPORTED PWRcell battery module MODULE STRING SIZE PER PV LINK OPTIMIZER 29 PV modules MAXIMUM RECOMMENDED DC POWER FROM PV 10kW 1Ø, 15kW 3Ø BATTERIES PER INVERTER Up to 2 3 3Ø inverters ofer islanding or 1Ø loads, 4 Modbus, *Reduced power at extreme temperatures RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSDC/DC CONVERTERS CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-40RAIL 232-02449,232-02450,232-02451 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANY REPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHE WRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USA PHONE(415)580-6900●FAX(415)580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 SECTION PROPERTIES A 0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³ DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 SPLICE 242-01213, 242-01214 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL N/A N/A 12 LB-FT UL 2703, FILE E359313 0.52 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, UR-40 SPLICE TAPPED PRC, CLEAR11 SNAPNRACK, UR-40 SPLICE THRU PRC, CLEAR12 SNAPNRACK, SNAPLINK BONDING CLIP, TYPE 2, STEEL23 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS14 1 2 4 3 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-60RAIL 232-02481,232-02482,232-02483 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANY REPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHE WRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USA PHONE(415)580-6900●FAX(415)580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 8.46 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 120 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-60 RAIL PROPERTIES SKU FINISH 232-02481 MILL 232-02482 CLEAR 232-02483 BLACK CENTROID .750 1.211 1.039 SECTION PROPERTIES A 0.515 in² Ixx 0.327 in⁴ Iyy 0.181 in⁴ Sx (TOP)0.270 in³ Sx (BOT)0.315 in³ Sy (LEFT)0.242 in³ Sy (RIGHT)0.242 in³ 2.250 1.500 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-60 SPLICE 242-01270, 242-01271 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL FULL UR-60 RAIL CAPACITY N/A 12 LB-FT UL 2703, FILE E359313 0.71 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS11 SNAPNRACK, UR-60 SPLICE, SLEEVE, CLEAR / BLACK12 SNAPNRACK, O-RING13 SNAPNRACK, UR-60 SPLICE, BONDING BRIDGE14 1 4 3 2 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT snapnrack.com 51 System Bonding Methods Grounding Specications RAIL CHANNEL NUT MODULE FRAME MID CLAMP ASSEMBLY SS BONDING PIN NOTE: SnapNrack Mid Clamp SnapNrack Adjustable End Clamp SnapNrack UR-40 Rail Splice SnapNrack UR-60 Rail Splice q   SnapNrack module clamps contain a SnapNrack Channel Nut with integral bonding clips or pins in assembly to properly bond the system (except Universal End Clamps). Note: SnapNrack Ground Lug Assembly SNAPNRACK ULTRA SERIES RAIL 5/16"-18 X 1" BOLT S.S. WITH SPLIT LOCK WASHER S.S. SNAPNRACK GROUND LUG, 6-12 AWG SNAPNRACK BONDING CHANNEL NUT COPPER WIRE, TYP. SS BONDING CLIP (2 TOTAL) RAIL SPLICE ASSEMBLY SnapNrack Ultra Rail Splices contain integral bonding clips in assembly to properly bond the system. Note:  RAIL SPLICE ASSEMBLY SS BONDING PIN (2 TOTAL) snapnrack.com 52 Grounding Specications Ground Path Details Ilsco Lay-in Lug Assembly SNAPNRACK ULTRA SERIES RAIL #10 BOLT SS ILSCO GBL-4DBT GROUND LUG #10 NUT SS WITH STAR WASHER COPPER WIRE, TYP. GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMP U = UNIVERSAL END CLAMP TO EGC RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT snapnrack.com 53 Grounding Specications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMP U = UNIVERSAL END CLAMP ENPHASE MICRO- INVERTER GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMP U = UNIVERSAL END CLAMP SOLAREDGE OPTIMIZER TO EGC TO EGC Ground Path Details - Enphase Ground Path Details - SolarEdge snapnrack.com 54 INSTALLATION INSTRUCTIONS - SNAPNRACK GROUND LUG 1) Snap the SnapNrack Ground Lug into the rail channel on one rail per module row. 2) Place grounding conductor into slot underneath split ring washer. SnapNrack Ground Lug may be used in side or top channel, and may be rotated 90 degrees relative to slot to acilitate running copper across top o rails. Install Note: SnapNrack Ground Lug only Listed or use with 6-12 AWG solid copper conductor. Install Note: 3) Tighten hardware to 16 t-lbs. Grounding Specications INSTALLATION INSTRUCTIONS - ILSCO LAY-IN LUG 1) Drill and deburr a 1/4” hole in the back side o the rail or the Ilsco lug to attach to, place the bolt through the hole, and attach the lug assembly on one rail per module row. 2) Place grounding conductor into slot. Torque rail connection to 35 in-lbs. Install Note: Torque set screw to 20 in-lbs or #10- #14 solid and stranded copper, 25 in-lbs or #8 stranded copper, and 35 in-lbs or #4-#6 stranded copper. Install Note: 3) Tighten set screw per Ilsco’s recommendation (see below). • System has been evaluated to a maximum overcurrent device (OCD) protection level o 20 Amps. • Universal End Clamp (UEC) does not bond module to rail. Be sure to separately ground any modules that are only secured by UECs, especially during servicing. • SnapNrack recommends that bare copper never come into contact with aluminum. • SnapNrack Ground Lug: torque bolt to 16 t-lbs. The Ground Lug may be used in side or top channel. It may be rotated 90 degrees relative to slot to acilitate running copper across top o rails. • Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling o a hole in the rail. • Ilsco hardware connection to rail: 5 t-lbs. Torque or lug set screw: #10-#14 solid and stranded copper- 20 in-lbs, #8 stranded copper- 25 in-lbs, #4-#6 stranded copper- 35 in-lbs. Note:RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT snapnrack.com 55 Ground Path Details - DynoBond Grounding Specications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)M M M M M M M M E E TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP E = END CLAMP(+)(-)E E M M M M E E E E DYNORAXX DYNOBOND R/C (QIMS2), DynoRaxx (E357716) photovoltaic bonding jumper cat. no. DynoBond is an optional component that may be used with this system. The DynoBond jumper has been evaluated to provide module to module bonding. The DynoBond device attaches to the rame ange o adjacent modules. August 6, 2019 SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Subject: Report # 2018-11940.03 – Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System PZSE, Inc. – Structural Engineers has reviewed and analyzed the SnapNrack Ultra Rail Racking System, a proprietary mounting system constructed from modular parts, which is intended for rooftop installation of solar photovoltaic (PV) panels; and has provided the attached span tables. This review included the complete system including the “UR-60” aluminum rail (6005-T56 alloy), attachment devices, splice elements, and PV Panels. All information, data, and analysis contained within are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2018 International Building Code, by International Code Council, Inc. 3. 2018 International Residential Code, by International Code Council, Inc. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5. Aluminum Design Manual 2015, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2015, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category II; Seismic Design Category = A - E Wind Loads: Basic Wind Speed (ultimate) per ASCE 7-16 = 95 mph to 190 mph. Includes roof pitches from 0° to 90°, up to 60 feet mean roof height, and exposure categories B, C, & D. Parapets, roof overhangs, and topographic wind speed adjustment have not been considered. Snow Loads: Ground Snow Load = 0 to 120 (psf). Spans are based on the sloped roof snow load (Ps) corresponding to each ground snow load. See Appendix A to adjust span tables for non-reducible snow loads. PV Modules: All solar PV modules with metal frames. “60-Cell” tables are applicable for modules up to 5’-6” (66”) long; “72-Cell” tables are applicable for modules up to 6’-6” (78”) long; and “Landscape” tables are applicable for modules up to 3’ 4-1/2” (40-1/2”) long in the narrow direction. Module length is defined to be perpendicular to the rail, regardless of panel orientation. If you have any questions, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA 1/923 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Subject: Engineering Certification for the State of Massachusetts Building Codes:1.ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2.2015 International Building Code, by International Code Council, Inc. 3.2015 International Residential Code, by International Code Council, Inc. 4.AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5.Aluminum Design Manual 2015, by The Aluminum Association, Inc. 6.ANSI/AWC NDS-2015, National Design Specification for Wood Construction, by the American Wood Council Design Criteria:Risk Category II Seismic Design Category = A - E Basic Wind Speed (ultimate) per ASCE 7-10: up to 190 mph Ground Snow Load = 0 to 120 (psf) This letter certifies that the loading criteria and design basis for the SnapNrack Ultra Rail Racking System with UR-60 Rail Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE,Inc.–StructuralEngineers Roseville, CA August 6, 2019 PZSE,Inc.–StructuralEngineershasprovidedengineeringandspantablesfortheSnapNrackUltraRailRackingSystemwithUR- 60 Rail, as presented in PZSE Report # 2018-11940.03, "Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Re:Report#2018-11940.03–SnapNrackUltraRailSolarPhotovoltaicRackingSystemwithUR-60Rail RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-109Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 n1.00 4.20 .30 3.25 n1.00 1.00 SLOT 1.50 2.78 1.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM n.35 1.80 105°RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-110Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ● Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ● UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-111Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSModel APKE00007, PWRcell Battery Cabinet Model A0000391219, 2.85kWh PWRcell Battery Module Certification Model Reference: BJ-DCB05ZKAX Model APKE00008, PWRcell Spacer Kit Model APKE00009, PWRcell Upgrade Kit Certification Model Reference for Battery Configurations: PWRcell 9, PWRcell 12, PWRcell 15, PWRcell 17 FEATURES & BENEFITS • Connect 2 PWRcell Battery Cabinets to a single PWRcell Inverter for 34.2kWh of storage • Best-in-class battery backup power • Plug-and-play with PWRcell Inverter and PV Link™ • Time-of-use (TOU) and zero-export ready • Residential and commercial application ready BATTERY CONFIGURATION GUIDE BATTERY CABINET ASSEMBLY PWRcell Battery Cabinet PWRcell 17 17.1kWh 6x Battery Module PWRcell 15 14.3kWh 5x Battery Module + Module Spacer Kit PWRcell 12 11.4kWh 4x Battery Module PWRcell 9 8.6kWh 3x Battery Module + Module Spacer Kit OR OR OR SPACER SPACER PWRcell Battery Cabinet Back PanelModule Spacer Kit x1 Battery Module x5PWRcell Battery Cabinet Front Panel The PWRcell™ Battery Cabinet is a modular smart battery platform that allows for a range of configurations to suit any need, small or large. No other smart battery oers the power and flexibility of PWRcell. Whether for backup power or smart energy management, PWRcell has power and capacity options for every need, without sacrificing flexibility or function. PWRcell BATTERY CABINET DESIGN The PWRcell Battery Cabinet allows system owners the flexibility to scale from the economical 8.6kWh PWRcell 9 to the massive 17.1kWh PWRcell 17 by installing additional battery modules to the PWRcell Battery Cabinet. When needs change, an existing PWRcell Battery Cabinet can be upgraded with additional modules. Use the graphic below and the chart on the back of this sheet to understand what components you need for your chosen PWRcell configuration. Specifications Generac Power Systems, Inc. S45 W29290 Hwy. 59, Waukesha, WI 53189 www.Generac.com | 888-GENERAC (436-3722) A0000528139 REV C ©2020 Generac Power Systems. All rights reserved. Specifications are subject to change without notice. UPGRADING PWRcell Inside of the PWRcell Battery Cabinet, battery modules are stacked two deep on three levels, allowing for up to six modules to be connected in series. You can upgrade an existing PWRcell Battery Cabinet by adding Battery Modules and a Module Spacer (APKE00008) if required. PWRcell 9 and PWRcell 15 require a module spacer. Generac oers a convenient PWRcell Battery Upgrade Kit (APKE00009) to help replace lost or misplaced hardware. A PWRcell Battery Upgrade Kit may be purchased from your Generac distributor. Refer to the table to the right for material requirements related to upgrading the PWRcell Battery Cabinet. UPGRADE MATERIAL REQUIREMENTS ENDING CONFIGURATION ST A R T I N G C O N F I G U R A T I O N PWRcell 17 PWRcell 15 PWRcell 12 PWRcell 9 + 3 x PWRCell Mod + 2 x APKE00009* + 2 x PWRCell Mod + 1 x APKE00009* + 1 x PWRCell Mod + 1 x APKE00009* PWRcell 12 + 2 x PWRCell Mod + 1 x APKE00009* + 1 x PWRCell Mod + 1 x APKE00008 PWRcell 15 + 1 x PWRCell Mod + 1 x APKE00009* *APKE00009 (Upgrade kit) only required if original hardware is unavailable PWRcell™ BATTERY CONFIGURATIONS 9 12 15 17 BATTERY MODULES:3 4 5 6 USABLE ENERGY:8.6kWh 11.4kWh 14.3kWh 17.1kWh POWER RATED CONTINUOUS: 3.4kW 4.5kW 5.6kW 6.7kW POWER 60 MINUTES:4.2kW 5.6kW 7.0kW 8.4kW POWER 2 MINUTES:5.0kW 6.7kW 8.4kW 10.0kW REbus™ VOLTAGE INPUT/OUTPUT: 360-420 VDC MODULE VOLTAGE:46.8 VDC ROUNDTRIP EFFICIENCY:96.50% OPERATING TEMPERATURE FAHRENHEIT CELSIUS: 41 to 113 °F 5 to 45 °C RECOMMENDED AMBIENT TEMPERATURE FAHRENHEIT CELSIUS: 55 to 86 °F 13 to 30 ºC MAXIMUM INSTALLATION ALTITUDE FT M: 9834 (3000) DIMENSIONS, L x W x H IN MM: 22" x 10" x 68" 559 x 254 x 1727 WEIGHT, ENCLOSURE LB KG:115 (52) WEIGHT, INSTALLED LB KG:280 (127)335 (152)390 (178)445 (202) WARRANTY LIION MODULES:10 Years, (7.56MWh) WARRANTY ELECTRONICS AND ENCLOSURE: 10 Years COMMUNICATION PROTOCOL:REbus™ DC Nanogrid™ COMPLIANCE:UL 9540, UL 1973, UL 1642, CSA 22.2 BATTERY CUT SHEET R-112Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-884411.520Bascomb, Christopher205 Emerson WayNorthampton, MA 0106206/25/2020SUBMIT FOR PERMIT