Enderle-Planset (1) solarRELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVINGJURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNAdvancedSolarSolutions39650MallardBassLake,CA93604 PHONE: 559-321-7000EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSEDWRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLEALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDEDAND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJREQUIREMENTS. ASCE 7-10 WIND SPEED: MSP RATINGS COMBINER(S) AZIMUTH TILT NORTH ⅊ ⅊ ⅊ ℄ HIG GIN S WA Y DRIVEWAY ℄HIGGINS WAY N/A VB 6.480 KW PV-001 COVER SHEET Enderle, Kimberly Steven Silverman 2015 National Grid 2015 22357164 2015 21134A(413) 584-8844 2020 Lilian Wanjiku(413) 584-8844 City Of Northampton Info@valleysolar.solar 50507Civil(202) 874-3483swyssling@wysslingconsulting.com R-3 Risk Category II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook Dr Alpine, UT 84004 Enderle, Kimberly79 Higgins Way, Northampton, MA 01060 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 REC REC360AAEnphase IQ7PLUS-72-2-US (240V) SnapNrack Ultra Rail UR-60 Snapnrack 242-01220 L Foot INTEGRATED IN INVERTER 1818 N/A 26 N/A 0 1 (E) GPS COORDINATE: (42.314571, -72.649001) 5.973 KW 2 120/240V - 1 36.9° 188° ROOF COVERING MAX. ARRAY HGT 117 N/AComp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS X-IQ-AM1-240-3 Enphase 200A BUS/200A MAIN BREAKER BACK-FED BREAKER PV-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS PROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS *ALLNOTESAREASAPPLICABLETOTHISPROJECT. CONNECTORSSHALLBERATEDFORWETLOCATIONS. ORBETTERRATED.ALLEXTERIORCONDUITAND3R EXTERIORELECTRICALEQUIPMENT,SHALLBENEMAALL STANDARDSBYALICENSEDCONTRACTOR. ANDGENERALBUILDINGANDROOFINGWORKMANSHIP SEALANTANDFLASHINGSWHEREREQUIREDPERCODE MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SHALLBESEALEDANDPENETRATIONSROOFTOPALLNEW :*WATERPROOFING .NEC110.12COMPLIANCEWITH BESECUREDINAWORKMANLIKEMANNERIN WILLPVMODULECONDUCTORSLOCATEDUNDERARRAYS .NEC200.6(A)(6)COMPLIANCEWITH MAYBEFIELD-MARKEDWHITEINPVWIREBLACKWIRE 2020NEC690.4(B)WITH FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE .PVMODULESWIRELEADSSHALLBELISTED690.31(C)(1) 2020NECASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE SHALLUSECONDUCTORSLISTEDANDIDENTIFIEDCIRCUITS EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT 310.15(B)(3)(4)(c) 2020NECSUNLIGHTINACCORDANCEWITH THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT ASAPPLICABLETOALLCONDUCTORSSHALLBEDERATED .NEC690.8,NEC690.7 INCOMPLIANCEWITHALLCONDUCTORSSHALLBESIZED TOUPSIZING. MINIMUMCODEREQUIREMENTSANDARENOTLIMITED CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND FORTHEIRINTENDEDPURPOSEINCLUDINGWET ITANDCONDUCTORSSHALLBEAPPROVEDALLCONDU DUITNOTES:*WIRING&CON .UL1699(B)LISTEDANDLABELEDINACCORDANCEWITH ANDSHALLBEUL1699B,NEC690.11COMPLIANCEWITH BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN GREATER.ALLDCPVCIRCUITSINSTALLEDINORON WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR FORALLPVSYSTEMSONORPENETRATINGABUILDING ISREQUIREDARCFAULT(AFCI)DCCIRCUITPROTECTION NEC690.9PROTECTIONINCOMPLIANCEWITH ;BOTHREQUIREOVERCURRENTUNGROUNDED BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE .240AND705.12,NEC690.8,690.9COMPLIANCEWITH SHALLBEINALLOCPDRATINGSANDTYPESSPECIFIED 2020NEC690.15(D) WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN REMAINBOTHPOSITIVEANDNEGATIVEPVCONDUCTORS 2020NEC690.15(A).DISCONNECT ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY SHALLBEPROVIDEDADDITIONALACDISCONNECTS NEC110.28PER DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER TYPE”KNIFEBLADE“SHALLBEAACDISCONNECTS ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND SHALLBELABELED,LOCKABLE,OFALLACDISCONNECTS (TYPICALLYTHEUPPERTERMINALS) OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS WILLBECONFIGUREDSOISCONNECTINGSWITCHESALLD ANDOCPDNOTES:*DISCONNECTS NEC690.9INSTALLATIONINSTRUCTIONSAND TOASINGLEOCPDINACCORDANCEWITHTHEIR SHALLBECONNECTEDMICROINVERTERBRANCHCIRCUITS 2020NEC705.12(B)(5)FROMADDITIONALFASTENING FORINVERTEROUTPUTISEXEMPTBACKFEEDINGBREAKER 230.42 NECENTRANCECONDUCTORSINCOMPLIANCEWITH WITHSERVICENEC705.12(A)COMPLIANCEWITH AREINSUPPLYSIDETAPINTERCONNECTIONS 705.12(B)(2)(3)(b)2020NECALSOBESIZEDAPPROPRIATELYASPER ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED 2020NEC705.12(B)(2)(1)COMPLIANCEWITH AREINALLFEEDERTAP(LOADSIDE)INTERCONNECTIONS NEC705.12(B)(2)(3)(c)COMPLIANCEWITH EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS 2020NEC705.12(B)WITH AREINCOMPLIANCE-SIDEINTERCONNECTIONSALLLOAD /POCNOTES:*INTERCONNECTION 2020NEC690.41(B)FAULTPROTECTION DCGROUND-PVSYSTEMSSHALLBEPROVIDEDWITH .AHJANDNEC250,NEC690.47COMPLIANCEWITH GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A .NEC250.106THROUGHNEC250.50ANDNEC690.47 COMPLIESWITHTHEGROUNDINGELECTRODESYSTEM MODULE. NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES SHALLBETHEGROUNDINGCONNECTIONTOAMODULE REQUIREMENTS. HOLESPERTHEMANUFACTURER'SINSTALLATION MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS APPROVEDUL2703INSTALLATIONMANUAL.IF SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S MODULEANDRACKGROUNDINGAPPROVEDUL2703 .NEC250.134ANDNEC250.136(A)COMPLIANCEWITH RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN CONDUCTIVEPARTSOFMODULEFRAMES,MODULE .250.122 NECTABLECONDUCTORSSIZEDINACCORDANCEWITH ANDMINIMUMGROUNDNEC690.43WITH INCOMPLIANCEMETALPARTSSHALLBEGROUNDED MODULEFRAMESANDOTHERINCLUDINGPVEQUIPMENT .250.136(A)NECAND250.134NECGROUND,INCOMPLIANCEWITH EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUNDINGCONDUCTOR.ALLMETALELECTRICAL AREUNGROUNDEDANDREQUIREANEQUIPMENT ONLYTHEDCCONDUCTORSEDSYSTEMSINUNGROUND NGNOTES:*GROUNDI RACKINGMANUFACTURESENGINEEROFRECORD. OUTLINEDBYTHEMAXSPANSTHEPRE-ENGINEERED ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ANDSHALLBEINSTALLEDINACCORDANCEUL1703WITH NDLABELEDINACCORDANCESHALLBELISTEDAROOFTOP &PVPANELSMOUNTEDONARACKINGSYSTEM NOTES:* ANDINSTALLATIONSTRUCTURAL APPLICABLE. WHENPURPOSEANDRATEDFOROUTDOORUSAGE LISTEDFORTHEIRINTENDEDALLCOMPONENTSARE APPLICABLECODES. NECWITHINCOMPLIANCEQUALIFIEDPERSONNEL ACCESSIBLETOALLEQUIPMENTSHALLBEINSTALLED 2020NEC690.15(A)SERVICINGDISCONNECT. WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SHALLBEPROVIDEDADDITIONALACDISCONNECT(S) .NEC690.34 INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH AREPERMITTEDTOBEDPULLBOXESJUNCTIONAN NOTES:* TLOCATIONS&ELECTRICALEQUIPMEN 2020NEC690.12(A)-(D)WITH CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE THATRAPIDSHUTDOWNFUNCTIONSHALLINCLUDEA ITSINSTALLEDONORINBUILDIDNGPVSYSTEMCIRCU WNNOTES:*RAPIDSHUTDO REQUIREMENTS. CLASSIFICATIONSASALLUL,IEC,IEEEAND NEC690.4AND690.6SYSTEMSINCOMPLIANCEWITH COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV TO,MODULES,INVERTERSANDSOURCECIRCUIT ;INCLUDINGBUTNOTLIMITEDPVSYSTEMCOMPONENTS NEC110.26.PROVIDEDASPERSECTION EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE AROUNDESSANDWORKINGCLEARANCEPROPERACC :*GENERALNOTES N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNPV SITE LAYOUT LEGEND * EXISTING DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 SHEET NOTE THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. A. B. C. RARA NORTH SECTION 1 DRIVEWAY PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/8"=1'-0"@ SHEET SIZE A3 188 22.6°SECTION-1 QTY 18 REC REC360AA MODULES QTY 18 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT2498 SECTION-1 339 13.57% SHEET NOTES RELEASEREVDATE NAME ADDRESS* EXISTING ROOF DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFING COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING * DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP B.ANCHOR SPACING SHOWNIN DETAIL. UNLESS NOTEDOTHERWISE PER RACKINGMANUFACTURER CERTIFIEDENGINEERED PRODUCT ANDLOCAL REQUIREMENTS. SEE"TABLE OF DIMENSIONS" EACH SECTION DETAILED FORHORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENTMANUFACTURERS. ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO ROOF RACKING RAIL NORTH 30'-4"9'-11"SCALE: 1/8"=1'-0"@ SHEET SIZE A3 Rafter - Strut to Walls Below 16" O.C. 2"x12" @ 16" MAX OC Comp Shingle 2.91 PSF QTY 18 REC REC360AA MODULES QTY 18 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 9:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 5'-4" AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND 21SCALE: NTS 3 4 A.THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODEREQUIREMENTS AT THE TIME IT WAS BUILT. C.STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING ISACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARYCONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL BE NO MORETHAN TWO LAYERS.(SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ONPLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUTSIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURALDETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I.AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES.STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRACKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSPER RAILMANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER MAX RAFTER SPANMAX RAFTER SPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOFCONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILSARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FORDESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTEDBY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL 1 5 6 7 HORIZONTAL SPAN HORIZONTAL SPAN RISE 12 VERIFY WALL OR BEAMBELOW ATTIC STRUT RIDGE BEAM FRAMING 3 OH1HS2HS1 PV 1 D3 D2 D1 D2H1R2R1* IF BLOCKING REQUIRED32 S-201 1 S-201 DIAGONAL AND/ORVERTICAL ATTIC STRUTS 2 S-201 12RISE HORIZONTAL SPAN HORIZONTAL SPAN VERIFY WALL OR BEAMBELOW ATTIC STRUT RIDGE BEAMDIAGONAL AND/ORVERTICAL ATTIC STRUTS 5 6 8 1 7 3 PV 1 D2D1 D1H1 OH1HS2HS1R1D3D2 * IF BLOCKING REQUIRED3 1 S-201 D3 D224" MINWHEN NOTSTAGGERED. TYPR2 ** COMP SHINGLE ROOF IN EXAMPLE. SAMEATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 (E) RAFTER@ 16" O.C. TYPICAL 1'-4"TYP 6'-0"MAX STRUTS TO WALL(S) / RAFTER - PORTRAIT STRUTS TO WALL(S) / RAFTER - LANDSCAPE STANCHION DETAIL STANCHION SPACING DETAIL Snapnrack Ultra Rail UR-60 Snapnrack 242-01220 L Foot L-Foot Flashing 12" 36.9° 3" - 6" TYP 10" 20" 20.25" 12" 12" 36.9° 3" - 6" TYP 16.94" 33.88" 34.12" 12" 15' Comp Shingle NOT USED S-200Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND * DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATIONINSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE: NTS 3 4 SCALE: NTS SCALE: NTSSCALE: NTS ATTACHMENT DETAILSROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSROOF RACKING RAIL ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" EMBEDMENT INTO FRAMING MEMBERS (E) ROOF SHEATHING /DECKING (E) FRAMING MEMBER L-FOOT PV MODULE, BY OTHERS MODULE END CLAMP SNAPNRACK ULTRA RAIL SNAPNRACK COMP UMBRELLA FLASHINGS5/16”-18 X 2-1/4” SS HCS BOLT 1/3" OF TOTAL SPAN MAX 2/3" OF TOTAL SPAN MAX RAIL MANUFACTURERRAIL SPLICE KITSEE "S-100 / TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE.SEE SHEET "S-100" FOR:HORIZONTAL ANCHOR SPAN SPACING. (E) FRAMINGTYPICAL * MODULES SHOWN PORTRAIT IN EXAMPLE DCAND/OR 1/3CANT.MAX COMPONENT +2" FROM SIDEOF MODULE 2" ROOF TOPCONDUIT EXTENSION OF RAIL RAIL OR STRUTCONNECTIONS TO MEETWEIGHT REQ. OF EQUIPMENT DCB * MODULES SHOWN PORTRAIT IN EXAMPLE** RAILING SHOWING IN VERTICAL IN EXAMPLE RIDGE BEAM *R2*R1VERIFY THAT NODIAGONAL AND/OR VERTICALATTIC/FRAMING STRUT MEMBERSARE CUT OR NOTCHED * SEE DETAILS "1-2/S200" TABLE OF DIMENSIONS HOLES ALLOWED ONLY IN MIDDLE HALF OF FRAMING SPAN 1/4 1/4 HOLES ALLOWED ONLY IN MIDDLE THIRDOF FRAMING DEPTH, *R2, AND NO LARGERTHAN *R2/4 IN DIAMETER. MINIMUMSPACING BETWEEN HOLES AT *R2 FRAMING SAG IN INCHES NOTTO EXCEED FRAMING LENGTHIN FEET DIVIDED BY 20 NOTCHES DEEPER THAN 1/4"NOT ALLOWED ALONG TOP ORBOTTOM EDGE OF FRAMING NOTE: WHERE FRAMING IS VISIBLE FROM ATTIC &/OR UNDERSIDE OF ROOF,VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURALDECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. RIDGE SAG IN INCHES NOT TO EXCEED RIDGELENGTH IN FEET DIVIDED BY 20 STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL RAFTER HOLE AND CONSTRUCTION DETAIL S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CALCULATIONSPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STCTEMPERATURE CORRECTEDTEMPERATURE MFR. PMAX TEMPCOEFFICIENT[-0.#%/C] * 100 FORMULA CORRECTEDTEMP.COEFFICIENT MODULE Voc[VDC] TEMPERATURECORRECTEDOPEN CIRCUITVOLTAGE-=*+=*= PV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/THICK PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (SHORT-CIRCUIT POWER)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC AC COMBINER (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) AC SUB-PANEL #2 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS AMPS (Imax) AMPS (Imax) MICRO INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs.DC INPUT Max PV POWER @ MODULE STC WATTS Max INPUT DC VOLTAGE VOLTS DC Max INPUT CURRENT AMPS MODULES PER MICRO INVERTER QTYAC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 ALT. ENERGY BACKFEED BREAKER (IF APPL.)AMPS (Imax) RECREC360AA4367.75 x 40 x 1.1836043.936.710.499.82-0.2420.0 EnphaseIQ7PLUS-72-2-US (240V)2902.38 2906015.01 240201.21 EnphaseX-IQ-AM1-240-324012523RN/A21.782 EatonDG221URB Non-Fusible2403023RN/A 21.78 EXISTING120/240V Single Phase200200 04030 -20 25 -45 -0.24%0.11 1 1.11 43.9 48.73 48.73 1 E-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUITORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 MAXCURRENT690.8 (A)(1) CONT.OPERATION690.8 (B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT.TEMP. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILLDERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY DC1 XXX=XX=<WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED.3. WIRE COLOR CODING (2020) CEC/NEC SECTIONS 250.119 & 200.6 PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT AREEQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED CONDUCTOR(S).TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES ADDRESS kW PHOTOVOLTAIC PLANSWHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED.USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. 4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF (in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT. AMPACITYCORRECTION310.15(B)(2)(a) # OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY <CORRECTEDAMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X = AC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < #OFCOMBINEDPARALLELCIRCUITS QTY INPARALLEL &MATERIAL QTY INPARALLEL &MATERIAL DESTINATION MAX INV. OUTPUTCURRENT (AMPS)ORCOMPONENT(AMPS) lsc (AMPS)ORCOMPONENT(AMPS) PV MODULE INVERTER (1) CU 90 #12 AWG 30 10.49 1 1.25 1.25 16.4 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 16.4 28.8 INVERTER JUNCTION BOX (1) CU 75 #12 AWG 25 1.25 10.89 13.6 ROOFTOP 35 >7/8"0 35 0.94 2 N/A 25 0.94 1.0 23.5 13.6 23.5 AC COMBINER (1) CU 75 #10 AWG 35 1.25 10.89 13.6 ATTIC 35 IN ATTIC 22 57 2 N/A 350.58 0.58 1.0 20.3 13.6 20.3 AC DISCONNECT (1) CU 75 #10 AWG 35 1.25 21.78 27.2 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 35 0.94 1.0 32.9 27.2 32.9 PRODUCTION METER (1) CU 75 #10 AWG 35 1.25 21.78 27.2 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 35 0.94 1.0 32.9 27.2 32.9 EXISTING SERVICE PANEL (1) CU #10 AWG 35 1.25 21.78 27.2 INT/EXT WALL 35 N/A 0 JUNCTION BOX AC COMBINER AC DISCONNECT PRODUCTION METER 75 35 0.94 3 1.0 35 0.94 1.0 32.9 27.2 32.9 E-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT LEGEND RELEASEREVDATE NAME ADDRESSDC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC#THREE LINE DIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 MICRO INVERTER 3 AC COMBINER BOX 4 JUNCTION BOX 5 NEW SOLAR LOAD CENTER 9 AC DISCONNECT (FUSIBLE) 7 PROD/GENERATION METER 8 SUB PANEL 10 NEW MAIN SERVICE PANEL 11 EXISTING MAIN SERVICE PANEL 12 EXISTING UTILITY METER GROUND CONDUCTOR TAGGND ELECTRICAL NOTES TAG APN ADDRESSBRANCH MODULE QTY OCPD BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 AC1 AC2 AC3 AC4 AC5 GROUND CONDUIT TABLE SIZE TYPE AC6 •INTEGRATED MICRO INVERTERS (AC MODULES) MUST BE CERTIFIEDUL1742 AND UL1703 COMPLIANT. AS EITHER INDIVIDUALCOMPONENTS OR AC MODULE ASSEMBLY. THEY MUST ALSO BELABELED "UTILITY INTERACTIVE" CONFORMING TO IEEE1547TESTING. •PV MODULES THAT HAVE INVERTERS ATTACHED WITHOUT AN ACMODULE EVALUATION BY A NRTL MAY VIOLATE THE ORIGINALLISTING OF THE PV MODULE AND VOID THE WARRANTY OFTHE MODULE. •VERIFY MODULE IS COMPATIBLE WITH MICRO INVERTERMANUFACTURER AND MODEL. •ARTICLE CEC/NEC 690 STILL APPLIES. THE INSTALLER WILL NEED TO CONSIDER REQUIREMENTS SUCH AS: DC GROUND FAULT DETECTION AND INTERRUPT, DC CABLE MANAGEMENT, DCDISCONNECTING MEANS AND DC GROUNDING AS WELL AS THE ACEQUIPMENT GROUNDING CONDUCTOR TO THE INVERTER. BACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS,UNLESS OTHERWISE MARKED, ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINE” AND “LOAD” SHALL NOTBE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITYINTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BE RATEDFOR 600 VOLTS ON THE DC / PV POWER SIDE OF THE INVERTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FORWET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FOR kW PHOTOVOLTAIC PLANSAC7 AC9 AC10 AC8 6 AC DISCONNECT AT GROUND LEVEL SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONSNOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS • INVERTER NAMEPLATE RATING 360W/240V MODULE NAMEPLATE RATING 360W L2 L1 G BUSRATING 3 EGC AC5AC3 L2 L1 L2 L1 GG NN 6 M 12 G N BUSRATING 11 MAIN C/BRATING GEC 125A 200A 200A L2L1 G N ENVOY-IQFOR MONITORING GEC N (-)(+) (-)(+) ACDC ACDC 2 2 9 MODULES 1 1 9 MODULES (+) (+) 2 2 AC DC(-) (-)DC AC 1 1 DC1 EGC AC1 20A G G L1 L1 L1 L1 L2 L2 L2 L2 L1 L1 L2 L2 AC2 20A 4 10A N G L2 L1 PV N G L2 L1 7 LOCATED EXTERIOR SOLAR GENERATION (LOAD) BOTTOM LUGS TO TOP LUGS TO UTILITY (LINE) MA SMART GENERATION METER R3METER NEMA LOCATED EXTERIOR ON WALL NEAR V 240A 30APPROACH TO RESIDENCE SYSTEM DISCONNECT VISIBLE FROM READILY ACCESSIBLE OPEN BLADE AC 4AC 30A (1) STRING OF (L1/L2 SHOWN) OF 9 MODULES (1) STRING OF (L1/L2 SHOWN) OF 9 MODULES NOTE: CONDUCTORS AC3, AC4 & AC5 MAY BE THWN-2 OR SER CABLE 18 REC REC360AA Enphase IQ7PLUS-72-2-US (240V) Soladeck RSTC 0799-5B Eaton DG221URB MA SMART GENERATION METER 1 9 20A 200A BUS/200A MB 2 9 20A 120/240V - 1 #12 AWG PV Wire Open Air 30A NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER CEC/NEC 705.12(B)(2)(3)(b) 18 1 1 0 1 1 0 0 0 1 1 2 #6 AWG N/A 3 #12 AWG TRUNK CBL #6 AWG N/A Open Air 3 #10 AWG NM-B #10 AWG N/A Open Air 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT Enphase X-IQ-AM1-240-3 E-003Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNELECTRICAL SYMBOL LEGEND SECTION 1 PV ARRAY TAGSECTION #MODULE GROUP AC DISCONNECT PERFORMANCE METER UTILITY METER JUNCTION BOXAC P M ELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES NEED TO BE CONNECTED TO THE EGC(EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPSOR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBSARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKINGSPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2.FOR "LAY-IN" LUG MODULE GROUNDING; CORRECTHARDWARE OF PROPER METAL MATERIAL TO AVOIDCORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED,TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BEATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TOBOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSEDMETAL PARTS THAT MIGHT COME INTO CONTACT WITHCURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THEMETAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS,DISCONNECTS, METERS, JUNCTION BOXES AND COMBINERBOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTSTO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THECONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THESYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT,OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECTCONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING,USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER.THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BEDUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP ADDRESS kW PHOTOVOLTAIC PLANSAUTO TRANSFORMERATFSOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATT CLP CRITICAL LOADS PANEL JB XFMR TRANSFORMER SUB-PANELSUBACCACSPMP NORTH JB SCALE: 1/8"=1'-0"@ SHEET SIZE A3QTY 18 REC REC360AA MODULES QTY 18 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER E-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSTANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSPV PANELS SOLAR ELECTRIC IN THE ARRAY. SHOCK HAZARD AND REDUCE SHUT DOWN PV SYSTEM “OFF” POSITION TO SWITCH TO THE TURN RAPID SHUTDOWN WITH RAPID SHUTDOWN SOLAR PV SYSTEM EQUIPPED SHUTDOWNSWITCHESIFNOTATTHESAMELOCATION.SHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDmFROMTHESERVICEDISCONNTLOCATENOMORETHAN11 BACKGROUND.INBLACKONWHITEREMAININGCHARACTERSMIN.3/16"BACKGROUND,YELLOWTITLE:MIN.3/8"BLACKCHARACTERSON3 )aCODEREFERENCE:NEC690.56(C)(1)(2 SCALE:1/4" = 1'-0" 2. IN WHITE ON RED BACKGROUND.⁄8 IN.),AND HAVING A MINIMUM HEIGHT OF 9.5 MM (3 FOR SOLAR PV SYSTEM RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH7 DO NOT DISCONNECT UNDER LOAD UNDERWRITERS LABORATORY (UL)INTERNATIONAL FIRE CODE (IFC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL BUILDING CODE (IBC)NATIONAL ELECTRICAL CODE (NEC)CODE ABBREVIATIONS: MANUFACTURED PRODUCT REDUCED AND / OR INCREASED TO UL APPROVED DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE 7.7. CONTRASTING SPACE BETWEEN ROWS OF TEXT7.6.ALL CAPITAL LETTERS.7.5.CONTRASTING BACKGROUND AND LETTERING.7.4. MINIMUM 1/16" LETTER HEIGHT FOR DATA7.3. MINIMUM 3/8" LETTER HEIGHT FOR HEADERS.7.2. ARIAL OR SIMILAR FONT, NON-BOLD.7.1. MARKING CONTENT AND FORMAT:7. REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969)NOT DETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TO THE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEREQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR6. LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED.COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THEOR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE5. BARRIERS. (IFC 605.11.1.4, NEC 690.31[G][3] )ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS ANDTURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOWASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE4. 690.13 & 690.53)BOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,3. BACKGROUND WITH AHJ APPROVAL.PLACE OF THE STANDARD WHITE LETTERS WITH RED BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN2. MULTIPLE PLACARDS MUST BE PRESENT.THE PLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROM COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE1. MAIN SERVICE PANEL 1/4" = 1'-0"SCALE:11 THREE LINE DIAGRAM AND CALCULATIONS.THAN ONE DISCONNECT IS USED. NUMBER ACCORDING TOUSE PLACARD "[AC][DC] DISCONNECT # 1" WHEN MORE INVERTER'S 1/2" = 1'-0"SCALE: WHITE LETTERS ON A RED BACKGROUND. 4. FONT: 3/8"3. MINIMUM OF 1" x 4"2. LINE DIAGRAM AND CALCULATIONS.INVERTER IS USED. NUMBER ACCORDING TO THREEUSE PLACARD "INVERTER # 1" WHEN MORE THAN 11. INVERTER # 1 1/2" = 1'-0"SCALE:SOLAR kWh METER WHITE LETTERS ON A RED BACKGROUND. 5. FONT: 3/8" AND .8 WIDTH FACTOR4. MINIMUM OF 1" x 4"3. VERIFY WHICH PLACARD IS REQUIRED WITH AHJ.2. USE PLACARD ON CUSTOMER GENERATION METER.1. DC DISCONNECTS WHITE LETTERS ON A RED BACKGROUND. 5. FONT: 3/8" AND .8 WIDTH FACTOR4. MINIMUM OF 1" x 6"3. USE ON NON-LOAD BREAK RATED DISCONNECTION.2. CODE REFERENCE: NEC 690.13(C)1. WHITE LETTERS ON A RED BACKGROUND. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR 4. MINIMUM OF 1" x 4" 3. THREE LINE DIAGRAM AND CALCULATIONS.DC COMBINER IS USED. NUMBER ACCORDING TO USE PLACARD "COMBINER # 1" WHEN MORE THAN 1 2. 1. DC COMBINER BOX 1/4" = 1'-0"SCALE:1/4" = 1'-0"SCALE: WHITE LETTERS ON A RED BACKGROUND. 5. FONT: 3/8"4. MINIMUM OF 1" x 10 1/2"3. CODE REFERENCE: NEC 690.13(B)2. PLACE ON ALL AC AND DC DISCONNECTS1. PV SYSTEM DISCONNECT AC AND DC DISCONNECTS WHITE LETTERS ON A RED BACKGROUND. FONT: 3/8" 4. MINIMUM OF 3 1/2" x 10 1/2" 3. 2. INCLUDES THE FOLLOWING:ON OR NO MORE THAN 1M (3 FT) FROM THE SWITCH THATA RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED1. MAY BE UNGROUNDED AND ENERGIZED NORMALLY GROUNDED CONDUCTORS IF A GROUND FAULT IS INDICATED, ELECTRIC SHOCK HAZARD WARNING: 1/2" = 1'-0"SCALE:INVERTER(S) WHITE LETTERS ON A RED BACKGROUND. 5. FONT: 3/8"4. MINIMUM OF 3 1/2" x 10"3. CODE REFERENCE: NEC 690.13(B)2. POSITION FROM THE PV SUPPLY.EQUIPMENT THAT STAYS ENERGIZED IN THE OFFPLACED ON DC DISCONNECT(S) AND ON ANY1. 1/2" = 1'-0"SCALE: OPEN POSITION SIDES MAY BE ENERGIZED IN THE TERMINALS ON BOTH LINE AND LOAD DO NOT TOUCH TERMINALS ELECTRIC SHOCK HAZARD WARNING: NON-LOAD BREAK DC COMBINER / J-BOX WHITE LETTERS ON A RED BACKGROUND. 5. FONT: 3/8"4. MINIMUM OF 3" x 10 1/2"3. DURING SERVICE.OR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSED PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITS2. ONLY FOR UNGROUNDED SYSTEMS.1. 1/4" = 1'-0"SCALE: BE ENERGIZED SYSTEM ARE UNGROUNDED AND MAY CONDUCTORS OF THIS PHOTOVOLTAIC ELECTRIC SHOCK HAZARD. THE DC WARNING: J-BOX, DC COMBINER, AND DC DISCONNECT REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. 5. FONT: 3/8" AND .8 WIDTH FACTOR.4. MINIMUM OF 1 1/8" x 5 3/4"3.CODE REFERENCE: NEC 690.31(G)(3)2. FROM BENDS, 12" ABOVE AND BELOW PENETRATIONS.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12"1. 4 1091/4" = 1'-0"SCALE:8 65 32CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 1/2" = 1'-0"SCALE:1 SHEET NOTES P-001QTY 18 REC REC360AA MODULES QTY 18 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNDYNAMIC PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSN (E) UTILITY METER& SERVICE PANEL AC DISCO SOLAR ARRAYON ROOF TOP N SOLAR ARRAYON ROOF TOP PRODUCTIONMETER AC COMBINER (E) UTILITY METER& SERVICE PANEL AC DISCO PRODUCTIONMETER AC COMBINER SHEET NOTES 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLEPLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2. 3. 4. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED INPLACE OF THE STANDARD WHITE LETTERS WITH REDBACKGROUND WITH AHJ APPROVAL. ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES,RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINERBOXES AND DISCONNECTS ARE MARKED. (IFC 605.11.1, NEC690.31[E][3], NEC 690.31[E][4], 690.17 & 690.53) REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FORTHE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BEWEATHER RESISTANT. UL STANDARD IS RECOMMENDED TODETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT, NON-BOLD.5.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS.5.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS. 5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BEREDUCED AND / OR INCREASED TO UL APPROVEDMANUFACTURED PRODUCT6.ANSI Z535.4-2014 PRODUCT SAFETY SIGNS AND LABELS: THISINFORMATIONAL NOTE AND ITS REQUIREMENTS FORPLACARDS MAY BE USED WITH PRIOR APPROVAL OF THE AHJ.MOST NOTABLE DIFFERENCES IS COLOR OF PLACARDS AND USEOF HAND WRITTEN VALUES WITH INDUSTRIAL MARKERS ONSTANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT AFUTURE DATE. I.E. ADDING MODULES AT A FUTURE DATE, ORSTANDARD PLACARD MANUFACTURER INSTALLED ONELECTRICAL COMPONENT. AHJ APPROVAL REQUIRED. (SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 2 3 4 SCALE:1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE:1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / AC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.54 4.MINIMUM OF 1 1/2" x 8 1/2" (TOP), 1 3/4" x 6 1/2" (BOT) 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1) PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEMSUPPLY BREAKER AT POINT OF INTERCONNECTION. (#2 & #3) PLACARD(S)REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT ARENOT LOCATED NEXT TO EACH OTHER. MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS. IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS; SEESHEET "E-001 / STRING INVERTER[#] SPECIFICATIONS". 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. 2.1.2."RATED AC OUTPUT CURRENT" WILL BE THE SUM OF THE INVERTERS2.1.3."AC NORMAL OPERATING VOLTAGE" WILL BE THE NAME PLATE RATING OF THEINVERTER 3.CODE REFERENCE: NEC 690.54, NEC 705.12(D)(3) 4.MINIMUM OF 2" x 6 1/2" (#1), VARIES (#2 & #3) 5.FONT: 3/8" HEADER, 3/16" DATA (#1), 1/4" (#2 & #3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE:1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION)SCALE:1/2" = 1'-0" CAUTION AC COMBINER AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING SCALE:1/2" = 1'-0" 1.CODE REFERENCE: NEC 690.16(B) AND NEC 690.17 2.USE PLACARD "COMBINER # 1" WHEN MORE THAN 1 AC COMBINER IS USED. NUMBERACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .75 TO .8 WIDTH FACTOR MINIMUM. 5.WHITE LETTERS ON A RED BACKGROUND. 6.PLACARDS MAY BE COMBINED TOGETHER. I.E. "AC COMBINER BOX #1". MINIMUM REQUIREMENTS LISTED ABOVE. AC COMBINER / DISCONNECT #1 AC SUB-PANEL #1 AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC COMBINER / DISCONNECT #2 AC SUB-PANEL #2 AC COMBINER / DISCONNECT #3 #1 #2 #3 CODE ABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE (IBC)INTERNATIONAL RESIDENTIAL CODE (IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY (UL) R331.2.3)THE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRC DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHEREPLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICE7. 1/8" DATA AND NOTES FONT: 3/4" "CAUTION", 1/4" "WARNING", 3/16" HEADER,6. MINIMUM OF 7 3/4" x 5"5. WHITE LETTERS ON A RED BACKGROUND.4. CODE REFERENCE: NEC 690.56(A)(B), 705.103.DISCONNECTION MEANS.DISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEM MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICE2. INVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PV1. OPERATED. (CFC 605.11.1.3 & CRC R331.2.3)VISIBLE FROM WHERE THE DISCONNECT ISCLEARLYSERVICE DISCONNECT IN A LOCATION MAINPLACARD WILL BE PLACED ADJACENT TO THE 7. AND NOTESFONT: 3/4" "CAUTION", 1/4" HEADER, 1/8" DATA6. MINIMUM OF 6 1/2" x 6 1/2"5. WHITE LETTERS ON A RED BACKGROUND.4. CODE REFERENCE: NEC 690.56(A)(B), 705.103. PHOTOVOLTAIC SYSTEM DISCONNECTION MEANS.SERVICE DISCONNECTING MEANS AND MAP PLACARD PROVIDES A DIRECTORY OF THE2. THE SAME LOCATION.THE PV INVERTER AND PV DISCONNECTS IF NOT AT PLACARD PLACED AT ELECTRICAL SERVICE AND AT1. 21.78 240 21.78 240 21.78 240 21.78 240 21.78 240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT rec Alphα Series αexperience performance 380 wp Power ELIGIBLE FOR www.recgroup.com 28 [1.1] 1721±2.5 [67.75 ±0.1] 802 [31.5]455 [17.9]956 [37.64]1016±2.5 [40 ±0.1]17 [0.7]45 [1.5] 1000 [39] 1200 [47] 11±0.2[0.43 ±0.8]6.6±0.2 [0.26 ±0.08]20.5±0.5[0.78 ±0.08] 30 [1.18] 22.5 [0.9] 621 ±3 [24.5 ±0.12] GR GR GR Ref: PM-DS1201Rev- D 03.20Specifications subject to change without notice.CERTIFICATIONS WARRANTY LOW LIGHT BEHAVIOUR TEMPERATURE RATINGS* MAXIMUM RATINGS Measurements in mm [in] 100 200 300 400 500 600 700 800 900 1000 85 90 95 100 Irradiance (W/m²) Typical low irradiance performance of module at STC: REC ALPHA SERIESPRODUCT DATASHEET Rel. Efficiency (%)Nominal Module Operating Temperature:44°C (±2°C) Temperature coefficient of PMAX:0.26 /°C Temperature coefficient of VOC:0.24 /°C Temperature coefficient of ISC:0.04 /°C *The temperature coefficients stated are linear values Operational temperature:40 ... +85°C Maximum system voltage:1000 V Design load (+): snow Maximum test load (+): 4666 Pa (97.5 lbs/sq )+ 7000 Pa (146 lbs/sq )* Design load (-): wind Maximum test load (-): 2666 Pa (55.6 lbs/sq )+ 4000 Pa (83.5 lbs/sq )* Max series fuse rating:25 A Max reverse current:25 A + Calculated using a safety factor of 1.5 * See installation manual for mounting instructions Founded in Norway in 1996, REC is a leading vertically integrated solar energy company. Through integrated manufacturing from silicon to wafers, cells, high-quality panels and extending to solar solutions, REC provides the world with a reliable source of clean energy. REC’s renowned product quality is supported by the lowest warranty claims rate in the industry. REC is a Bluestar Elkem company with headquarters in Norway and operational headquarters in Singapore. REC employs around 2,000 people worldwide, producing 1.5 GW of solar panels annually. IEC 61215:2016, IEC 61730:2016, UL 1703, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 1703 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 612152:2016 Hailstone (35mm) AS4040.2 NCC 2016 Cyclic Wind Load ISO 14001:2004, ISO 9001:2015, OHSAS 18001:2007, IEC 62941 Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 989898 Annual Degradation 0.250.250.25 Power in Year 25 929292 See warranty documents for details. Conditions apply. ELECTRICAL DATA Product Code*: RECxxxAA Power Output - PMAX (Wp) 360 365 370 375 380 Wa Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 36.7 37.1 37.4 37.8 38.1 Nominal Power Current - IMPP (A) 9.82 9.85 9.9 9.94 9.98 Open Circuit Voltage - VOC (V) 43.9 44 44.1 44.2 44.3 Short Circuit Current - ISC (A) 10.49 10.52 10.55 10.58 10.61 Power Density (W/sq )19.15 19.41 19.68 19.94 20.21 Panel Efficiency () 20.6 20.9 21.2 21.4 21.7 Power Output - PMAX (Wp)274 278 282 286 289 Nominal Power Voltage - VMPP (V) 34.6 35.0 35.2 35.6 35.9 Nominal Power Current - IMPP (A) 7.93 7.96 8.00 8.03 8.06 Open Circuit Voltage - VOC (V) 41.4 41.5 41.6 41.6 41.7 Short Circuit Current - ISC (A) 8.47 8.50 8.52 8.55 8.57 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one wa class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 /s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GENERAL DATA Cell type: 120 half-cut cells with REC heterojunction cell technology 6 strings of 20 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflection surface treatment Backsheet:Highly resistant polymeric construction Frame:Anodized aluminum (black) Junction box:3-part, 3 bypass diodes, IP67 rated in accordance with IEC 62790 Connectors:Stäubli MC4 PVKBT4/KST4, 12 AWG (4 mm²) in accordance with IEC 62852 IP68 only when connected Cable:12 AWG (4 mm² PV wire, 39 + 47 in (1 + 1.2 m) accordance with EN 50618 Dimensions:67.8 x 40 x 1.2 in (1721 x 1016 x 30 mm) 18.8 sq (1.75 m²) Weight:43 lbs (19.5 kg) Origin:Made in Singapore STC NMOTRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSPV MODULE CUT SHEET R-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT 8IMTSIIQEMIE EIMEREIM EQEMEPPMQTPMIMREPPEMSRTSIMPI achievingthehighestsystemefciency. 4ESIRTEI-57IQI-5ER -51MSMRIIMRIEIMIRTEI -5RSRTEI-5EIERIRTEI Enlighten™monitoringandanalysissoftware. -57IMI1MSMRIIIIRIIPMEMPM EREISTIMSIRIEMSRER RISSIEQMPPMSRSSTSISRIMR IREPMRRTEISTSMIERMRPIEMR warrantyofupto25years. EI E MMII 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ EE7II EIMMIIIMSR1-7 )EWXS-RWXEPP 0MLXIMLXERHWMQTPI *EWXIVMRWXEPPEXMSRMXLMQTVSIHPMLXIVXSMVIGEFPMR &YMPXMRVETMHWLYXHSRGSQTPMERX2) 4VSHYGXMIERH6IPMEFPI 3TXMQMIHSVLMLTSIVIHGIPPERHGIPPQSHYPIW 1SVIXLEREQMPPMSRLSYVWSXIWXMR PEWW--HSYFPIMRWYPEXIHIRGPSWYVI 90PMWXIH 7QEVX+VMH6IEH SQTPMIWMXLEHERGIHVMHWYTTSVXSPXEIERHVIUYIRGVMHIXLVSYLVIUYMVIQIRXW 6IQSXIPYTHEXIWXSVIWTSRHXSGLERMRVMHVIUYMVIQIRXW • Congurableforvaryinggridproles 1IIXW%6YPI907% 8LI-51MGVSMWVIUYMVIHXSWYTTSVXGIPPQSHYPIW2SIRSVGIH(%VEXMS7IIXLIGSQTEXMFMPMXGEPGYPEXSVEXLXXTWIRTLEWIGSQIRYWWYTTSVXQSHYPIGSQTEXMFMPMX2SQMREPSPXEIVERIGERFIIXIRHIHFISRHRSQMREPMVIUYMVIHFXLIYXMPMX0MQMXWQEEV6IIVXSPSGEPVIUYMVIQIRXWXSHIMRIXLIRYQFIVSQMGVSMRIVXIVWTIVFVERGLMRSYVEVIE 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ ©2018EnphaseEnergy.Allrightsreserved.AlltrademarksorbrandsusedarethepropertyofEnphaseEnergy,Inc. -2((-7-7 -77-77 SQQSRPYWIHQSHYPITEMVMRWz ;;;; 1SHYPIGSQTEXMFMPMXGIPP4:QSHYPIWSRPGIPPERHGIPP4:QSHYPIW 1EMQYQMRTYX(SPXEI :: 4IEOTSIVXVEGOMRSPXEI :::: 3TIVEXMRVERI :::: 1MR1EWXEVXSPXEI :::: 1E(WLSVXGMVGYMXGYVVIRXQSHYPI-WG%% 3IVSPXEIGPEWW(TSVX ---- (TSVXFEGOIIHGYVVIRX %% PVarrayconguration YRVSYRHIHEVVE2SEHHMXMSREP(WMHITVSXIGXMSRVIUYMVIH%WMHITVSXIGXMSRVIUYMVIWQE%TIVFVERGLGMVGYMX (-MVSMIVIV -MVSMIVIV 4IEOSYXTYXTSIV :%:% 1EMQYQGSRXMRYSYWSYXTYXTSIV :%:% 2SQMREP00SPXEIVERIs :::::::: 1EMQYQGSRXMRYSYWSYXTYXGYVVIRX %:%:%:%: 2SQMREPVIUYIRG,, )XIRHIHVIUYIRGVERI ,, %WLSVXGMVGYMXEYPXGYVVIRXSIVGGPIW %VQW %VQW 1EMQYQYRMXWTIV%00FVERGLGMVGYMXt :%:%:%:% 3IVSPXEIGPEWW%TSVX ------ %TSVXFEGOIIHGYVVIRX %% 4SIVEGXSVWIXXMR 4SIVEGXSVEHNYWXEFPIPIEHMRPEMRPIEHMRPEMR )--)2 PeakCECefciency CECweightedefciency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kW PHOTOVOLTAIC PLANSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-40RAIL 232-02449,232-02450,232-02451 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 SECTION PROPERTIES A 0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³ DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 SPLICE 242-01213, 242-01214 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL N/A N/A 12 LB-FT UL 2703, FILE E359313 0.52 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, UR-40 SPLICE TAPPED PRC, CLEAR11 SNAPNRACK, UR-40 SPLICE THRU PRC, CLEAR12 SNAPNRACK, SNAPLINK BONDING CLIP, TYPE 2, STEEL23 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS14 1 2 4 3 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-60RAIL 232-02481,232-02482,232-02483 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 8.46 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 120 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-60 RAIL PROPERTIES SKU FINISH232-02481 MILL232-02482 CLEAR 232-02483 BLACK CENTROID .750 1.211 1.039 SECTION PROPERTIES A 0.515 in² Ixx 0.327 in⁴ Iyy 0.181 in⁴ Sx (TOP)0.270 in³ Sx (BOT)0.315 in³ Sy (LEFT)0.242 in³ Sy (RIGHT)0.242 in³ 2.250 1.500 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-60 SPLICE 242-01270, 242-01271 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL FULL UR-60 RAIL CAPACITY N/A 12 LB-FT UL 2703, FILE E359313 0.71 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS11 SNAPNRACK, UR-60 SPLICE, SLEEVE, CLEAR / BLACK12 SNAPNRACK, O-RING13 SNAPNRACK, UR-60 SPLICE, BONDING BRIDGE14 1 4 3 2 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT snapnrack.com 51 System Bonding Methods Grounding Specifications RAIL CHANNEL NUT MODULEFRAME MID CLAMP ASSEMBLY SS BONDING PIN NOTE: SnapNrack Mid Clamp SnapNrack Adjustable End Clamp SnapNrack UR-40 Rail Splice SnapNrack UR-60 Rail Splice q   SnapNrack module clamps contain a SnapNrack Channel Nut with integral bonding clips or pins in assembly to properly bond the system (except Universal End Clamps). Note: SnapNrack Ground Lug Assembly SNAPNRACKULTRA SERIES RAIL 5/16"-18 X 1" BOLT S.S.WITH SPLIT LOCK WASHER S.S. SNAPNRACK GROUNDLUG, 6-12 AWG SNAPNRACK BONDING CHANNEL NUT COPPER WIRE, TYP. SS BONDING CLIP(2 TOTAL)RAIL SPLICEASSEMBLY SnapNrack Ultra Rail Splices contain integral bonding clips in assembly to properly bond the system. Note:  RAIL SPLICEASSEMBLY SS BONDING PIN(2 TOTAL) snapnrack.com 52 Grounding Specifications Ground Path Details Ilsco Lay-in Lug Assembly SNAPNRACKULTRA SERIES RAIL #10 BOLT SS ILSCO GBL-4DBT GROUND LUG #10 NUT SSWITH STAR WASHER COPPER WIRE, TYP. GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMPU = UNIVERSAL END CLAMP TO EGC RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT snapnrack.com 53 Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMP U = UNIVERSAL END CLAMP ENPHASEMICRO-INVERTER GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP SOLAREDGEOPTIMIZER TO EGC TO EGC Ground Path Details - Enphase Ground Path Details - SolarEdge snapnrack.com 54 INSTALLATION INSTRUCTIONS - SNAPNRACK GROUND LUG 1) Snap the SnapNrack Ground Lug into the rail channel on one rail per module row. 2) Place grounding conductor into slot underneath split ring washer. SnapNrack Ground Lug may be used in side or top channel, and may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. Install Note: SnapNrack Ground Lug only Listed for use with 6-12 AWG solid copper conductor. Install Note: 3) Tighten hardware to 16 ft-lbs. Grounding Specifications INSTALLATION INSTRUCTIONS - ILSCO LAY-IN LUG 1) Drill and deburr a 1/4” hole in the back side of the rail for the Ilsco lug to attach to, place the bolt through the hole, and attach the lug assembly on one rail per module row. 2) Place grounding conductor into slot. Torque rail connection to 35 in-lbs. Install Note: Torque set screw to 20 in-lbs for #10- #14 solid and stranded copper, 25 in-lbs for #8 stranded copper, and 35 in-lbs for #4-#6 stranded copper. Install Note: 3) Tighten set screw per Ilsco’s recommendation (see below). • System has been evaluated to a maximum overcurrent device (OCD) protection level of 20 Amps. • Universal End Clamp (UEC) does not bond module to rail. Be sure to separately ground any modules that are only secured by UECs, especially during servicing. • SnapNrack recommends that bare copper never come into contact with aluminum. • SnapNrack Ground Lug: torque bolt to 16 ft-lbs. The Ground Lug may be used in side or top channel. It may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. • Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling of a hole in the rail.• Ilsco hardware connection to rail: 5 ft-lbs. Torque for lug set screw: #10-#14 solid and stranded copper- 20 in-lbs, #8 stranded copper- 25 in-lbs, #4-#6 stranded copper- 35 in-lbs. Note:RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT snapnrack.com 55 Ground Path Details - DynoBond Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)M M M M M M M M E E TO EGC MOUNT M MODULE CLAMPM = MIDCLAMP E = END CLAMP(+)(-)E E M M M M E E E E DYNORAXX DYNOBOND R/C (QIMS2), DynoRaxx (E357716) photovoltaic bonding jumper cat. no. DynoBond is an optional component that may be used with this system. The DynoBond jumper has been evaluated to provide module to module bonding. The DynoBond device attaches to the frame flange of adjacent modules. 1/953 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Subject: Engineering Certification for the State of Massachusetts Building Codes:1.ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2.2015 International Building Code, by International Code Council, Inc. 3.2015 International Residential Code, by International Code Council, Inc. 4.AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5.Aluminum Design Manual 2015, by The Aluminum Association, Inc. 6.ANSI/AWC NDS-2015, National Design Specification for Wood Construction, by the American Wood Council Design Criteria:Risk Category II Seismic Design Category = A - E Basic Wind Speed (ultimate) per ASCE 7-10: up to 190 mph Ground Snow Load = 0 to 120 (psf) This letter certifies that the loading criteria and design basis for the SnapNrack Ultra Rail Racking System with UR-40 Rail Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA August 6, 2019 PZSE, Inc. – Structural Engineers has provided engineering and span tables for the SnapNrack Ultra Rail Racking System with UR- 40 Rail, as presented in PZSE Report # 2017-03227.11, "Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Re: Report # 2017-03227.11 – SnapNrack Ultra Rail Solar Photovoltaic Racking System with UR-40 Rail RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSRACKING & RAIL CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 n1.00 4.20 .30 3.25 n1.00 1.00 SLOT 1.50 2.78 1.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM n.35 1.80 105°RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-109Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT 8I)EI-QMIRTEI -RSSRSPEIRIVSRRISR ITQIRRSERPIIRPSVIER VIEQPRIERSVEIREPPESR TVSRESRIRTVIVISPSRSV VIIREPETTPESR-SIVTSSV TSPIRTVERESRIVI EVEIQP )EI -QMI -1 8SPIEVRQSVIEFSX)RTLEWISIVRKWWX EEII )EI2IXM QEVX -RPIW-)RSSVSQQREXSR ERSRXVSP PIFPIRIXSVORKWTTSVXW )XLIVRIXSVIPPPEV 3TXSREPVIITXEPIEEPEFPISV40 FVKI 4VSIWTVSXSRQIXIVRKERSTXSREP SRWQTXSRQSRXSVRK QTPI 6IIWIVSQTVISWSQFRIV IRXIVIQSRXRKFVEOIXWWTTSVXWRKPI WXQSRXRK TTSVXWFEOERWISRXIRXV 9TXSSVTSPIFVERLVXWSV TPKRFVIEOIVWRSXRPI XSXEP4SVWXSVEKIFVERLVXW 6IPEFPI • DurableNRTL-certiedNEMAtype 6IRPSWVI IIEVEVVERX 90PWXI 8SPIEVRQSVIEFSX)RTLEWISIVRKWWX kRTEIRIVPPVVIIVIPPVEIQEVSVVERRSQIREVIVIIVIIVVITIISRIV IQCombiner3X-IQ-AM1-240-3 -SQFRIVXL)RTLEWI-)RSTVRXIVXFSEVSVRXIKVEXIVIIRIKVEI4productionmetering(ANSIC12.20+/-0.5%)andoptional*consumptionmonitoring(+/-2.5%). ERRSXRPISVIVWITEVEXIP EnphaseMobileConnect™CELLMODEM-03(4G/12-yeardataplan)CELLMODEM-01(3G/5-yeardataplan)CELLMODEM-M1(4GbasedLTE-M/5-yeardataplan) 4PKERTPERWXVEPKVEIIPPPEVQSIQXLEXETPERSVWWXIQWTXSmicroinverters.(AvailableintheUS,Canada,Mexico,PuertoRico,andtheUSVirginIslands,wherethereisadequatecellularserviceintheinstallationarea.) ConsumptionMonitoring*CT840-8 Splitcorecurrenttransformersenablewholehomeconsumptionmetering(+/-2.5%). VXVIEOIVWBRK-10A-2-240BRK-15A-2-24064 SupportsEatonBR210,BR215,BR220,BR230,BR240,BR250,andBR260circuitbreakers.Circuitbreaker,2pole,10A,EatonBR210Circuitbreaker,2pole,15A,EatonBR215VXFVIEOIVTSPI)EXSR6 EPLC-01 4SIVPRIEVVIVSQQREXSRFVKITEVUERXX XA-PLUG-120-3 AccessoryreceptacleforPowerLineCarrierinIQCombiner3(requiredforEPLC-01) )246ITPEIQIRX-)RSTVRXIVXFSEV4SVSQFRIV 6EXRK SRXRSWX WXIQSPXEKI 120/240VAC,60Hz )EXSR6WIVIWFWFEVVEXRK 125A Max.continuouscurrentrating(outputtogrid)65A Max.fuse/circuitrating(output) Branchcircuits(solarand/orstorage)Uptofour2-poleEatonBRseriesDistributedGeneration(DG)breakersonly(notincluded) Max.continuouscurrentrating(inputfromPV) Max.totalbranchcircuitbreakerrating(input)80Aofdistributedgeneration/90AwithIQEnvoybreakerincluded ProductionMeteringCT WSPSVITVIRWXEPPIERVIXS-)RS Dimensions(WxHxD)49.5x37.5x16.8cm(19.5”x14.75”x6.63”).Heightis21.06"(53.5cmwithmountingbrackets). IKLX 7.5kg(16.5lbs) QFIRXXIQTIVEXVIVERKI -40ºCto+46ºC(-40ºto115ºF) SSPRK 2EXVEPSRIXSRTPWLIEXWLIP )RPSWVIIRVSRQIRXEPVEXRK Outdoor,NRTL-certied,NEMAtype3R,polycarbonateconstruction VIWIW 20Ato50Abreakerinputs:14to4AWGcopperconductors60Abreakerbranchinput:4to1/0AWGcopperconductorsMainlugcombinedoutput:10to2/0AWGcopperconductorsNeutralandground:14to1/0copperconductorsAlwaysfollowlocalcoderequirementsforconductorsizing. PXXI To2000meters(6,560feet) -RXIKVEXI802.11b/g/n )XLIVRIX Optional,802.3,Cat5E(orCat6)UTPEthernetcable(notincluded) IPPPEV Optional,CELLMODEM-01(3G)orCELLMODEM-03(4G)orCELLMODEM-M1(4GbasedLTE-M)RSXRPI SQTPERISQFRIV UL1741CAN/CSAC22.2No.107.147CFR,Part15,ClassB,ICES003Productionmetering:ANSIC12.20accuracyclass0.5(PVproduction) SQTPERI-)RSUL60601-1/CANCSA22.2No.61010-1 *ConsumptionmonitoringisrequiredforEnphaseStorageSystems. )EI-QMIRELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC COMBINER CUT SHEET R-110Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch UPC: 782113120232 Dimensions: Height: 6.25 IN Length: 5.73 IN Width: 6.1 IN Weight:5 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 30A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG221URB Certifications: UL Listed Product compliance: No Data DG221URB © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy-duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general-duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-111Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88446.480Enderle, Kimberly79 Higgins WayNorthampton, MA 0106006/16/2020SUBMIT FOR PERMIT