Loading...
12C-057 (2) 26 HAROLD ST BP-2020-1198 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 12C-057 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-1198 Proiect# JS-2020-002006 Est.Cost:$17000.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: SUNBUG SOLAR 109144 Lot Size(sa.ft.): 10628.64 Owner. LACROIX M IXI. Zoning: RI(100)/URA(100)/WSP(100)/ Applicant: SUNBUG SOLAR AT. 26 HAROLD ST Applicant Address: Phone: Insurance: 411 A HIGHLAND AVE (413) 884-1000 O W(' SOMERVILLEMA02144 ISSUED ON:6/4/2020 0:00.00 TO PERFORM THE FOLLOWING WORK:4.2KW SOLAR ON ROOF - 14 PANELS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footinhs: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 6/4/2020 0:00:00 $75.00 212 Main Street, Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner DocuSign Envelope ID:8FBFA8EB-48DC-4CE2-8973-0C8D2E30FC6E The Commonwealth of Massachusetts r--- - Board of Building Regulations and Standards FOR Massachusetts State Building Code,780 CMR CIPALITY Building Permit Application To Construct,Repair,Renovate Or Demolish a Revi r 201 One-or Two-Family Dwelling o18M This Sec ' n For Official Use Only Building Pen-nit Number: / Date.Applied: 0 Cr Building Official(Print Name) Signature �— ate SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 26 Harold St i 1G 0'J? J 1.la Is this an accepted street?yeses_ no Map Numi, Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Residential- Solar Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal El On-site disposal system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owners of Record- Bredoet Mulkerrins/Steven Lacroix Florence, MA 01062_ Name(Print) City,State,ZIP 26 Harold St No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORD (check alt that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units Other M Specify: Solar Brief Description of Proposed Work2: Install 4.2 kW solar on roof per attached documents. (14ap nels) SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials 1.Building $ 5,000 1. Building Permit Fee:$ Indicate how fee is determined: [3 Standard City/Town Application Fee 2.Electrical $ 12,000 ❑Total Project Cost'(Item 6)x multiplier x_ 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ - 5. resanic Total All Fees Check No. Check Amount:_ J Cash Amount: 6.Total Project Cost: $ 17,000 ❑Paid in Full 0 Outstanding Balance Due: DocuSign Envelope ID:8FBFA8EB-48DC-4CE2-8973-0C8D2E30FC6E SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS 109144 07/21/21 Aaron Simms License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 66 Westfield Ind Park Rd No.and Street — Type Description Westfield, MA 01085 U Unrestricted(Buildings u to 35,000 cu.ft.) R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC RoofinR Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-884-1000 aaron.simmsCsungbugsolar.com _ I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) CheneyBrand-Sunbu Solar LLC 163091 05/10/21 9 HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 4-11A Highland Ave-Suite 312 cheney.brand@sunbtrgsolar.com No.and Street Email address Somerville, MA 02144 413-884-1000 Cit /Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes.......... M No........... D SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize SunBua Solar to act on my behalf,in all matters relative to work authorized by this building permit application. Steven Lacrpt5r,54�°' Bridget Mul 3/17/2020 3/16/2020 I Shu, (air?. I bviLid MU(1•MWS Print Owner's N ("&da"nic Signature) Date SECTION 7b: OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Dmuftrad by: Aaron Simms 5/21/2020 Print Owner's or Au 560WL*(Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his4wr own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.o, 142A. Other important information on the HIC Program can be found at www.mass. og v� /oca Information on the Construction Supervisor License can be found at www.mass.g:ov/dpss 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.)_ Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms_ Number of half/baths Type of heating system Number of decks/porches Type of cooling system _ Enclosed Open 3. "Total Project Square Footage"maybe substituted for"Total Project Cost" WESTSHORE DESIGN ENGINEERS, P.C. 100 GREAT OAKS BLVD. I SUITE 115 ALBANY I NEW YORK 1 12203 To: SunBug Solar 66 Westfield Industrial Park Rd. Westfield, MA 01085 Date: April 24, 2020 Ref: 20040544 Subject: Mulkerrins Residence 26 Harold St. Northampton, MA To Whom It May Concern, The following references the Mulkerrins Residence in Northampton, MA: 1. Existing roof framing,: Conventional framing is 2x6 at 20"o.c. with a 9'-7" max. span (horizontal rafter projection). This existing structure is capable to support all the loads that are indicated below for this photovoltaic proj ect 2. Roof Loading: - 4.33psf dead load(modules plus mounting hardware) - 40psf ground snow load - 5.7psf roof materials (1.7psf 2x6, 1.5psf sheathing, 2.5psf asphalt shingles) - Exposure Category B, 140mph wind(3 sec.) This installation design will be in general conformance to the manufacturer's specifications,and complies with all applicable laws, codes, and ordinances, specifically the International Building Code/IBC 2015 and International Residential Code/IRC 2015 including all MA regulations and amendments. The spacing and fastening of the mounting brackets is to have a maximum of 48"o.c. span between mounting brackets, staggered, and secured using 5/16" diameter corrosive resistant steel lag bolts. A minimum of 3" of penetration per lag bolt is required, which is adequate to resist all 125mph wind live loads including wind shear. Per NDS Section 11.1.4 clearance holes equal to the diameter of the shank need to be bored into primary a primary framing member for the full length to the threaded portion of the screw to avoid splitting of the framing member. Thank you. `IN0FmASSA`yD Westshore Design Engineers oEC.�" sF� NICOLAS A. NITTI CIVIL NO. 50222 o RECISTERE� Q ��FESSION A1 EN��a�� April 24, 2020 John Eibert Nicolas Nitti, PE Project Coordinator President WestShore Design Engineers 1 100 Great Oaks Blvd. I Suite 115 1 Albany,NY 12203 1518.313.7153 s 1 n` 1 � l 1 � Or. Y \ 1 1 l \ 1` 1 \ SATELLITE IMAGE SHOWN FOR REFERENCE ONLY l N LEGEND Stale:I"=20`-0 ". E PROPERTY LINES 0 20' 40' S, SETBACKS OWNER: DESBNADRA"NGB/MICKELONa CONFIDENTIAL J08 REFERENCE: 2567—Wes—W Mulkerrins, Bridget SYSTEM SIZE: 4.2 WV DC DESCR6'f10N. DATE REv MUSETHEINFFOR FIE HEREIN OF ANYONE EXCEL NOT SENSED SORRMDR OFMTONE IX[EPf Ctpnai 5�11lA]0 1 SU6UGSIX/R U.C.LLC.NOR SNAILITBEDISCLOSED MOUNTING SYSTEM: SnapNRack Ultra Rall Rocking 26 Harold St. MONITORING: Enphpse IQ Combiner+ Sundtlg s� TOOTHERS OUTSDE OF SJNBUG SOLAR LLC, WTHOUTCONSENTORINCONNECnONWTHTHE Northampton, MA 01062 UTILITY: NatanolGrid mAHpa�eA+asw�T SN,E AND 16E OF THE RE>PECnVE 9JNBUG SIXCA MODULES: (14) Mission PERC 300 LLC SYSTEM Son ,NA 02144 INVERTER: 14 IQ7 Microinverter 508 647-8966 SHEETTTTLE: PROPERTYPUW SHEETNLMBER:1 r(6+n 7WeE 2�OHa7m7 ( � SNEETSIZE:11k17' smagvlm.\an �}-.� °, ,x.. .. v.. ., m... ..v•.vi�. ..r+W.r+ rwp'•;N.. � .. .. ,.,� . 'y,�}vy,..,w,.w.lwln.,...... . . w.... .., y� r=� Aw p ° "at zc f •4 'wv r •. r rlA.i�l'•A_ i F i t r i .t t Y F T . I 1 1 I I I I I II I I t I I i I I I j I M)MSE300SQ5T (10.)1 a7 PLUS I I I 1 I I I I AC DISCONNECT MA SMART ME 01'IQ I UTILITY SEWCE METE ! I N I I F I S I I LEGEND SITE PLAN I Q UTILfTYMETER BWARNINGLABEL SCak.1/EP- t I INVERTER 8 WARNING LABELS 0 1' 8' t8' --— II DC DISCONNECT 8 WARNING LABELS AC DISCONNECT 8 WARNING LABELS CONFIDENTIALOWNER: OESON&DPWINGBY MC AELLYNp MEINFORUTATIONNERBNCONTANEOSKALNOT �BREFERENCE: 2567-Wes-W Mulkerrins, Bridget SYSTEM SIZE: 4.2 kW DC DESCRIPTON DATE REV BEUSEDFORTWSENERTOFANYONE EXCEPT mel `.,/11!)x1 I SUNOUGSOIARLLC NORSHALLITEIEDISCLOSED MOUNTING SYSTEM SnapNRack Ultra Rail Racking 26 Harold St. MONITORING: Enphose IQ Combiner+ Sun Bug Solar TO OTHERS DUTSDE OF SUNDUG SOUR LLC. wT OUT CONSENT OR IN CONNECTION WTHTNE MODULES: (14) Mission PERC 300 Northampton, MA 01062 UTILITY: NotionalGrid 1I,AK0-AY,s�Fr7 SALE A,DUSEOFTPERESPECTWESUNBUGSOLAR "me kMA02111 LLC SYSTEM 508 847-8966 111,T)A NNF(61n1122^a INVERTER: (14) IQ7 Microinverter SHEETTITLE:SITE PLAN SHEETNUMBER:2 SHEET SIZE:11'.17' +���Lv—mm ATTACHMENT PLAN LAYOUT PLAN MAK MAX. AL OVESPAN ,O AX.RAL SPAN 48' POSITION RAILS 0-(MIN HI I 65jWX)FROM EDGE OF MODULES N PORTRAIT ONLY STAGGER STANDOFFS,SEE STRUCTURAL REPORT ROOF FRAMING MPI RAFTERS2(01P OC W WA W2 WA MPS WA MPD WA W WA ARRAY POSITION POSITION MPI ROOF ARRAY CENTERED ON ROOF ADDITIONAL WORK CRITTER GUARDS WA I I INVISIBLE END CLAPS WA , A I_ I I .--�_._._ ___ i __A SNOWGUARDS WA I i I I 1 I SERVICE UPGRADE WA I I I 1 1 I STRUCTURAL NO RENFORCET.ENT REQUIRED I 1 I I 1 I 1 REINFORCEMENT 1 1 1 1 1 1 1 1 I 1 1 1 SPECIAL PERMITTING 1 1 1 1 1 1 I WA i 1 1 1 1 I 1 1 I 1 I 1 1 1 1 L 1 I 1 1 1 EQUIPMENT LOCATION 1 1 1 L 1 1 I I 1 I 1 1 1 1 ENVOY IQ MOUNT N BASEMENTAWACENT TO PANEL I 1 1 1 1 1 1 1 1 i 1 1 1 I 1 1 1 1 1 1 PROD.METER MOUNT MASMART METER SOCKET OUTSIDE NEAR AC I 1 1 1 1 1 1 DISCO,LEAVE METER SOCKET EMPTY 1 1 1 1 1 1 AC DISCONNECT INSTALL WITHIN 10 FT OF UTILITY METER, MIST BE READILY ACCESSIBLE 1 1 1 1 1 1 PROJECT NOTES SNR MD CLAMPS,END CLAMPS,RAIL SPLICES TORQUE TO IOFT-LBS N F S OWNER Mulkerrins, Bridget SYSTEM SIZE: 4.2 kW DC DEscla PnoNREVISI DATEREV DESGNcaumrcaY NOMELLMCH TIE It J08 REFERENCE: 2567—Wes—W . .IEIKOCIRMARUN nON HERBAL CONTNNW SIW11 N07 SE USED FOR ME BENEFIT OF INTONE EKCEW ❑qmm SII IRPlD 1 SUWG S"LLC.NOR 91ALIT HE DISCLOSED MOUNTING SYSTEM. SnapNRock Ultra Roil Racking 26 Harold St. MONITORING: Enphose IQ Combiner+ Sun B{�Solar TOOTIERSMUDE OF SMBJG SOUR LLC, AITHDUTCONSEWrORINCONNECna+wTHTNE MODULES: (14) Mission PERC 300 Northampton, MA 01062 UTILITY: NationalGrid 1„nw an,a.sNre3,: "LE IND USE OF THE RESPECT1W SUNDA SOLA ITC StSfEA Sa 31133.NA 17tH 508 847-8966 T 6m sm-aTe F rom n7 na7 INVERTER: (14) 107 Microinveftef SHEET TITLE:CONSTRUCTION PLAN SHEET NUMBER:3 SHEET 512E:11•e7 rr smWRmM,om MOUNTI NG PLAN i i MOUNTING METHOD n SCALE 1*=1-0. c I I SNAPNRACK SNAPNRACK ULTRA RAIL END CLAMP OR UNIVERSAL SNAPNRACK L-FOOT PJ MODULE ULTRA RAIL SNAPNRACK FLASHING MOUNTING 506'WSS LAG SCREW HARDWARE MIN 2.5'EMBEDMENT RAIL POSITION PLAN VIEVE MOUNTING DETAIL n SCN.E 3N'=t'.0' SCALE 7-1'0* `R D r 9 7 CONRDENRN. JOB REFERENCE: 2567—Wes—W OWNER:Mulkerrins, Bridget SYSTEM SIZE: 4.2 DESGNSDRRW By WCAELL"NCH THE IWOREVITIONHERBNCONTNNEDSAJ-NOi OESCRIPn ON DATE REV BE USED FOR THE SENERT Of ANYONE E(CEPT Orginel 5Tt/Op , SMGSO LLC.NORSHAUTBEaSCLOSED MOUNTING SYSTEM SnapNRack Ultra Rail Racking 26 Harold St. MONITORNG: Enphase IQ Combiner+ Sungug50lar Ta OTHERS OUTSIDE OF WMG SOLAR LLC, WMOUTCANSENT ORIN CONNECTION WH THE MODULES: (14) MiS6lanl PERC 300 Northampton, NA 01062 UTILITY: NotionalGrid H,AHp.Nm Are.s�r ra SALE AND USE OF THE RPSPECTAE SUNBUG SDL* A10W AV OSA LLC 508 647-6966 TMIm5Noa 3B f(61T� axe INVERTER: (14) IQ7 Microinverter SHEET TIRE:MOUNTING PLAN SHEETNUMBER:4 SHEETSIZE INIr ...—0.w— BRANCH _ � CIRCUIT 1 BRANCH CIRCUIT 2 OWNER: USGNSORa T1 BY xiCi ELLYNCH CoxADENTPI JOB REFERENCE: 2567—Wes—W Mulkerrins, Bridget SYSTEMSFE: 4,2 kW DC DESCRIPTION DATE Rev Ti USED MR nE ER COxrANNE 6XCEKkL NOT BE USED"D `I'NOP AANYONE EXCEPT a9+�al 5'11R02G 1 s,.�sussouRac.xoRSHaLITaEascros® MOUNTING SYSTEM SnapNRack Ultra Rail Racking 26 Harold St. MONRORNG: Enphase IQ Combiner+ Sun Qti9`•�CYlOf TOOTHEASOVTZ; OE StwAUG SODA LLC, WTHOUTCONSENTORNCONNECTION WTHTHE MODULES: (14) Mission PERC 300 Northampton, MA 01062 UTLtTY: NotionolGrid 4MHqu. ft@Sw3,2 SAIEAID USE OE THE RESPECT\£SLNEUG 9JIAR SomenJe.NA 0211/ LLC SYSTEM 508 847-8966 T�einND-v>aT�+nnz2om NVERTER: (14) 107 Microinverter SHEETTRLE:STRMGDIAGRAM SHEETNIIMBER:5 SHEET stff:ii•Stt• Groundin S cs N Existing Electrical Specs E Tie in Description Inverter Specs Module Specs General Notes BOND*8 GEC TO TWO CROUSE HINDS Tie-In:Back-Feed Breaker 14 Enphase IQ7-60-2-US 14 MISSION SOLAR MSE300SQ5T EXTERNAL PIPE RUN GROUND RODS AT PANEL Panes Info Inv.100A/2P Main Breaker 235-350 W,240V,97%,AFCI 300 W 276.9 W PTC NEXT TO UTILITY WITH IRREVERSIBLE CRIMP Meter Number 93276143 Inv: AC Ungrounded VOC: 40 Vpmax: 32.8 125A Raters Main Panei Service Entrance Overhead Ise And Imp Are Shown in the DC string labels (E)WING ENPHASE TYP. MP1:1x7 MSE300SC15T Panels 4 144 SMART 4 U"-tl d 9 IQC-bher3 2 Jmdun Boz 1–AG_ Wdh 1X7107 100AZP Melet ENVOY __ nc M crokrverte s (EI LO"DS METER 20A ___ EGC_________________i A r— (1 11 " i MP1:lx7MSE300SQ5TPanels " z0A 2 1 Ac. Wdh 1X7107 40A2P __ _ Grp _ _ __ _ G ________ ____ GCl , Ac Microinverters " �___________ A B I I EGC EG J L _ _____ __ _____ —_______—_______________ I _ I N I EderiorAC&co ct I EAkrior IaayownM EGwEt 1 pnIftion miler z – _ -- TO T21INUv SINGLE PHASE lfTY1TV SERVICE (E)129 MAIN PANEL SW EXT. BASEMENT @ UTILITY METER @ MAIN PANEL ROOFTOP CORNER PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPD SHUTDOYAl AC Disconnect Label tee&thi eurrent t ai wok _ 4 (3)AWG#10,THWN-2 3 (3)AWG #10,THWN-2 2 (2)AWG#10,THWN-2 1 (2)AWG#12, (Enphase Q cable) 3o n (1)AWG*6,THWN-2 Gnd loo ft 1)AWG#10,THWN-2, Gnd 3c ft (1)AWG#10,THWN-2 20 H (1)AWG#6, Bare Cu EGC 1'Conduit 1"Conduit CONFIDENT& OWNER: BEaGNaORAFnrwar Nar,EurNa THEll ORKAnoNNERENCOKTANEDSHA_LNOT JOB 2567—Wes—W MUlkerrins, Bridget SYSTEM SIZE: 4.2 kW DC oEscRlPnoN onrE. Rtv BE USED FOR THE BENEFIT OF ANYONE E(CEPr 0*.1 Y11(A20 i SO.NBUG SOLAR LLC,NOR SHALL IT SE DISCLOSED MOUNTING SYSTEM: SnapNRack Ultra Rail Racking 26 Harold St. MONITORNG: Enphase IQ Combiner+ Sw+6u85olor M OTHERS OLn90E OF 9AMG SOLAR LLC, WTIEWTCONSENTORINwrNEwo"WTHTHE MODULES: (14) Mission PERC 300 Northampton, MA 01062 UTILITY: NationalGrid N,AH�eMArASWAT2 SYE AND USE OF THE RESPECTIAE SUNBJG SO `� ft,eA 02144 ILC SYSTEM 508 847-8966 TIslN saa.aTa FISTn NaBaQ NVERTER: (14) IQ7 MicroinNerter SHEETTtfLE:ELECTRICAL DIAGRAM SHEETNUMBER: t sHEET9zE:tnt7• Commonwealth of Massachusetts Division of Professional Licensure �- Board of Building Regulations and Standards Construction Supervisor CS-109144 Expires: 07/21/2021 AARON SIMMS 42 LEAD MINE RD SOUTHAMPTON MA 01073 Commissioner ti _ -- � Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Horne Improvement Contractor Registration R-4 Type: LLC 1Registration: 163091 SUN BUG SOLAR LLC. ? Expiration: 05/10,12021 411A HIGHLAND AVE. ST 312 d ' = � = .� SOMERVILLE VA 02144 a I Update Address and Return Card. SCA 1 0 20M-05117 .//r- �rviriirrisrii'rr�/f r`, i/�r�i•)r�r�ii-ii//i Office of Consumer Affairs E. Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE: LLC; before the expiration date. If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 163091 05/10/2021 1000 Washington Street - Suite 710 SUN BUG SOLAR LLC, Boston, MA 02118 CHENEY BRAND 411A HIGHLAND AVE. ST 3121w1`r- SOMERVILLE, MA 02144 Undersecretary Not valid without signature �� DATE(MMIODIWYY) A C" CERTIFICATE OF LIABILITY INSURANCE F4/30/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER.,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). CO PRODUCER Commercial Global Insurance Services of CA, LLC NAAME: Commercial Global Insurance Services of CA LLC 20 Pacifica, Suite 450 (A/�No EM: 949.600-7995 A1C No: 949-600-7998 Irvine, CA 92618 E-MAIL ADDRESS: INSURERS AFFORDING COVERAGE NAIC• www.cgislic.com CA DOI License No.OG13559 INSURER A: Gotham Insurance Company 25569 INSURED INSURER e: New York Marine and General Insurance Co 16608 SunBug Solar, LLC, SunBug WM, LLC, SunBug, LLC INSURER 411 A Highland Ave#312 suRERc: NatuilusInsurance Company Somerville MA 02144 INSURER D: INSURER E: INSURER F COVERAGES CERTIFICATE NUMBER: 55295553 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTVNTHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR POLICY NUMBER MMIDDIYYYY MMMDD ✓ COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1 100010WDAMAGE To RENTED— _ CLAIMS-MADE a OCCUR PREMISES Me occurrence $100,000 A PK202000010568 4/30/2020 4/30/2021 MED EXP(Any one person) s5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 JJECT LOC PRODUCTS-COMP/OP AGG $ POLICY� E 2,000,000 OTHER: $ AUTOMOaILELIABILnY COMIEa ac idents E LIMIT $1,000,0W ✓ ANYAUTO 130DILY INJURY(Per person) $ B OWNED SCHEDULED AU202OW0168M 4/30/2020 4/30/2021 AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HIRED✓ AUTOS ONLY ✓ AUTOS ONLY PROP cid DAMAGE $ $ UMBRELLALIAB ✓ OCCUR EACH OCCURRENCE $5000000 _ A ./ EXCESS LIAR CLAIMS-MADE EX202000001495 4/30/2020 4/30/2021 AGGREGATE $5 ODO 000 DED I ✓I RETENTION$10,000 $ WORKERS COMPENSATION PER AND EMPLOYERS'LIAR ILI TY ✓ STATU YTE ER B OFFICER/MEMBBE EXCLUDED?ECUTIVE ❑ N/A M202000015422 4MM20 4/30/2021 E.L. 0 L.EACH ACCIDENT $10000 _. (Mandatory in NH) EL.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below EL.DISEASE-POLICY LIMIT $1,000,000 A Professional Liability-Claims Made PK202000010568 4/30/2020 4/30/2021 Each Wrongful Act: $1,000,000 Retroactive Date 01/01/2009 Aggregate Limit: $1,000,000 C Excess Prof Liability-Claims Made �BD 4/30/2020 4/30/2021 Each Wrongful Act:$1,000,000 Retroactive Dat /2020 Aciareclate Limit: $1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Evidence of Insurance-SunBug Solar, LLC;SunBug WM, LLC&SunBug, LLC CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE EVIDENCE OF INSURANCE ONLY THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS, AUTHORIZED REPRESENTATIVE ^�� — Bart J.Le Fevre/KSK /� ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD 55295553 1 20-21 GL AL XS WC PL I Sally Huynh 1 4/30/2020 3:06:46 PH (PDT) I Page 1 of 1 t. r' fl:'j Cti!4}t 11`ri'+G'31S .:j0i 1 Ott , . . (4"' lar i;. i"• - r A1. 'otjt:K01",A'."0"Irr%t',. >h,,,.;j?,✓i.t ^r',�;t , G ,. ,.!�G;•1:th.'l�.il't .l t.". t/l-' ,:pii!'81{7", •.') , .1�A •. a... In.u.y. (' I• �.H. ,rd 4�.( i,. V 1.. �i'_r'.J , . .J C. '4 •i''Mt f .,.`'�•. .y CIT t as it L 6 of .. •!.. a.i t f ' d•. ',V .l FXn N1.�a,• `_. 1. it .x >'.�j+r ;; `A. t I r,t `?,v yA 5 r a+ '.3°'A• yYI i"IkBJ: '. _ 1.,. 1 `U�' _,.. ....._ ._ mlt;, _ - 1 1 _ +:�.v'L.', a',i S�. - - ,...N�. t :.. r.�^� •.+LS .."�j.Is. '!;, .. :".�.y!+j.t�.- r:. •. _. 'T:_' f.- —.. M. •� ' r d��S',C' - .5, t .1i.i. �(:;�'� rtS:�'ti i e::'-�`t�:!t;3i•1 .,.t�F•:. ' , ,�, raj&; �'1t• 1�.��, t r• _ _ ;' �ffUNM lV I S t `` ' t�� -f t� r ..a • " ; !l ri'•I% .>i+� 1 - .. !ro nr�.�Ir-, o ,'.'.;'i{:.j,�,,t, a�� . �':..:, n, t.,,. _�{t��.,%arn,:r;i, ;;' a•r•; ._ ,..1-; . • � s .. - r.+ 't"rtt' '4sa, r ,.tx'^ts ,. m :.0 �Jti4,. „ � {� t_t d.�_i^' ''Et M 1•'+ '}{t i �l 1 Y � tia •.i:(`f, ..$t; ,?ft;. 6p'. �1. L.- .. 4'. �:..± Yrh_....t�;•r.l tat,'... ��E,titf(`i',-« t!-er1�^�� •tj ,i,.r; SVu 9rlec., ... ..._._ �......... _ ... _._. ` 'ttW" `7 14 ft xi(j i�,i C"'1? h i jl. e't:t[i�t' i{?�Ii "i#' .I,., ;.liC'll'tt: _ ir.+'.',' ia•a+ ••7+:.ui'-J(I.. t,r, 1 ti 1 d.r �)C t#I. .i`;"t ;t Si: .l��w L.^ t .. . ct� � .`( i Lf�' 'ra`..1n1.4�t� �,.. _�;'�x. .. ,,,3"f•�rS. ...... ......... _..._.._...._.,... .. �_.. _._ _... .. .. _._ i .r .r } ,.rG '�i Y.i4' l t�!.+ v�..•• �t t ,.r/` ".! .,'tt, �• .,- -.;1-' t '1N`.�"',c r' ,.i,. r' (il'.P .. . � .�./_` -.. ri, 1. itlN•r' i : rt .d'4 '(F.J. 'ZPid,.!•1 '+'� ':Y'd'11- tf .t rWC► �:vt I t0l ' ' h ._ t.:� - f'a♦.`�. fa-+ + •i,':" < < 1'.. �•�.. It. �r .�.. y ♦�w�. .M/�{■sow■y[�/t,� `�/'�t� �}` �, _ �k �'.. 14b!, . tr/���rt���.:-� �i ^ .r�� t. �.�"!I ^CSP�•Y't,.'o'+ � � ' - t "\ The C'ominonwalth (If?Iloswchtimrtl r tF ,,w� Departmentof 1►rdu�triul. l rc irlcrnt� - Office of lnrc�Vtil,�ations iY L ajap'c'tte ON Center 2Awnr►e tie La%al'ctte, Roston, MA 02111-1750 www murr.got/dict Workers'Compensation Insurance AftidaN it: Builders/Contractors/Electricittny/Plumbers Applicant information Please Print Legibly Name SunBug Solar Address:411A Highland Ave„ Suite 312 city/StatelZip:Somerville. MA 02144 hhonc 11:617-500-3938 _ _ - - - -- Type of project (requre i : Are you an employer-? Check the appropriate box: dl 1.Q I am a cnipluyi-r s,.ith 59 4 [� I ani it general contractor and 1 ti F-jNcw construction rinployecs i full and/or part-time). lime hired the sub-contractors '_ 1 ant a %-ilc proprietor or part»rr_ listed on dic attached sheet. 7 ❑ Remodeling ship and has no cmploNces 1'hcsc sub-contractors hose K C Qernolition ssorkin g for inc in am ca acih employees and have workers � , IS;o workers' comp. insurance p. ? ( 3 Building addition i corn insurance.: i rcqutrcd] 5 ❑ We are it corlwation and its 10.E Electrical repairs or additions El I am a honico%%ner doing all work officers has a exercised their I I.F Pluinbing repairs or additions rtn-self INo tsorkers' compright of exemption per MGL I '.C ltixif repairs titsurancc required.] ' c 152. J10). and sse hase no emplo�ces I\o%corkers 13.�,OtpurSOlaf Installation _ compinsurance rt:yu►rcd.) 'AnN ap plic mi that ehxks hnx:.1 mint a'.so fill out info-matioo. .14<ame,-wricis.wh.-submit this alfidavit indicaimp they are"ng all wrxk.and fluor hav outside contractors must wbmii a new aftidasit indicating such •Cmaracumthat chock this her must ultuhad an additional.sheet showing;ilac uamc of the sub•aaitr",t(w%:mt1 elate whc chc; ,t th,x er!1:r.,f,r\c crn;Ao�.c if the%ub-(xm1nwtorxha\c cmplowv,they musl Vto%ide shear cwikers'cvinp.policv nunil, + I am an emplui•er that is providim', imuranc e jew nti-einploi-ces. l elms is the pi'Ll ilntl irh silt, information. Insurance C<►mpan\ Name New York Marine and General Insurance Co Potic• #or Sclf-ins lac WC202000015422 Expiration Date 04/30/2021 J++h site Addicss .attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). )-aiture to sec:urc ws°cragc as required under Section 25A of MCiL c 152 can lead Lo dic intpoNition of Omit tl penalues of a j tine up to$1.500 00 an(Vor one-sear imprisonment, as well as civil penalties in the form of a S IOP WORi: ORDER and a fine of up to$250.00 a dac against die violator. Be advised that a copy-of this statement nuns he tonsarded to the Otlicc of lnscstgr.itions of the DIA for insurance co%,:rayc scrilication I do hereb.l �erlifi- under the Loin%and penalties of pe•rjtlrl• that the inl(Armation prc,ivded ahove i.t true and L orrt•,7. 413-884-1000 llfficial ase'unll•. 110 nor arritc•in t/ric urr•cr, to hc•rumplrtc•cl ht+e•in�nr tu►r,r r►f�cicrl City or•how n:_ _ Permit/License b issuing Authority(check ones): i[]Board of Health 20 Building Department .311('ityrl'own Clerk 411 l•. ct I i ical Inspector 5altinihing inspector I'hunc rr; "4 MISSION SOLAR ENERGY • Power Rooftop Class Leading Output: L OA 30OW power Advanced Technology: ((� PERC and 4 busbars drive I >18% module efficiency Superior Aesthetics: j All-black design coupled with i outstanding power output Certified Reliability: 3X IEC, salt mist, ammonia Buy American Act S As"s bliA Compliant liant m The us Proudly assembled in the USA Mission Solar Energy is headquartered in San Antonio, TX with module all-black design c• • '• with facilities onsite. Our hardworking team outstanding •• - output makes it idealfor • calls Texas home and is devoted to including commercial and rooftop producing high quality solar products and services. Our supply chain includes local and domestic vendors Passivated Emitter Rear Contact • •• provides increasing • •- increasing our impact to the U.S. excellent power output through • -• cell structure. economy. Mission Solar Energy production lines are fully automated and include multiple quality checks throughout the production process. Assembled in the USA CERTIFICATIONS 25-YEAR LINEAR WARRANTY IEC 61215/IEC 611730/IEC 61701 UL 1703: CSA Independently Audited by 100% 7% Mission Sglar Energy Warranty -O'SOLARBUYER o 90/o 80.2% TOV""11nleq PowerGuard soda SVL Ciw L:I'.n S6R n'4CC S(Rv CES As there are different certification requirements in different markets,please contact your local Mission Soler Energy sales 70% representative for the specific certificates applicable to the 1 5 10 15 20 25 products in the region In which the products are to be used. YEARS ILL "" •t+Y6"'f' ,:v, '4't +�c'� 3t r +F7.1 ' S.a,��r��? :y! � r+r3A y` .r � :, +,;�:. '#�M.r i t t ,.� ai•,p,�� n 44 va 44 r r.iv.✓v.:.o+ i� ,. is'��.#.' � `'b � .. .��`.= ��'+�s•.k��"-:.lSr�i��'`', ,:9 :�Cy:+5 .^ e t' J s• "� .* i� i �I^ .� i'. +J< ... l',. �t+ !t ^� ,SSL«. ' �y.w yl�kr.� � }V .�`.. w 9+ ,j.. v+•iF: t1_, � �r. .� ,. . +, 3 � �`u_^ c, � 4,• a` .. s. ,�y_ t iia a iM 1 .,' _ .•a.i •w ,i- .r... a....i..�".. .. « .- ,:. y. ` ` '� � t. L '�. 4 ' ! .. �' C•�+t.' i' '�t.:� .tai•. �-fG' �,. v�. ` {�' �5., t�f, i�J� Ni� 'Fi �1r � ,'J �'�t� 1,' �• t x`, - 1 ,� :.r. 4, +�'+rV a V • .,c�* .+ -�� �f.;w r i' vt t�'� t.� � tr r..t.: 2.R ..1.. 1' ,W ... 5.;..: �O '.f'' 7�.A.�. �,+ t e � + • 1, �1 �i .1� .� fir. ' A� `.5 'v � ;�,, fit•�+!1 o w p�i��`f�1F,'i� i`� F 'k►' , ^aiNlk.rw•scv..,....'. . Ja - • ` r i ?'..y�N7wMi' (A .MM.•+wY4. .. •a�.K.,n« W...• . 5 1y T..:1'�, :'S':- ..d?K'.. •, `-F!A s 1,sm .fit� � why `t t• f ELECTRICAL SPECIFICATIONS Electrical parameters at Standard Test Condition(STC) Module Type MSE290SQ5T MSE295SQ5T MSE30OS05T .......................... .......... ....... ...................................... ...................................... ....................................... Power Output Pmax Wp 290 295 300 .......................... .......... ..o... ...................................... ...................................... ....................... ................ Module Efficiency /° 17.45 17.75 18.05 ............... .......... ....... ...................................... ............... .............. ....................................... Tolerance0"+3% .......................... .......... ....... ...................................... ...................................... ....................................... Short-Circuit Current Isc A 9.44 9.52 9.61 .......................... .......... ....... ...................................... ...................................... ....................................... Open Circuit Voltage Voc V 39.81 40.11 40.18 .......................... .......... ....... ...................................... ...................................... ....................................... Rated Current Imp A 8.95 9.03 9.17 .......................... .......... ....... ...................................... ...................................... .................................. . Rated Voltage VmpV 32.54 32.72 32.80 STC:Irradiance 1000 W/m2,Cell temperature of 25°C,AM 1.5 TEMPERATURE COEFFICIENTS MSE295SQ5T: 295WP, 60CELL SOLAR MODULE Normal Operating Cell Temperature(NOCT) 44-C(±2-C) CURRENT-VOLTAGE CURVE ...................................................... ........................._ 12 Temperature Coefficient of Pmax -0.427%/°C CellsTemp.=25`C Temperature Coefficient of Voc -0.318%/'C to Incident Irrd=1,000 W/m' - •.••.•••.••..•.••• .......................... ••. •••••. Temperature Coefficient of Isc 0 g Incident Irrd.=800 W/mz ........................................................ .......................... a 6 Incident Irrd.=600 W/m' OPERATING CONDITIONS ` UIncident Irrd.=400 W/m' Maximum System Voltage 1,000VDC 6 ........................................ .......................................... Operating Temperature Range -40°C(-40°F)to+90°C(194°F) 2 Incident Irrd.=200 W/m2 ........................................ .......................................... Maximum Series Fuse Rating 15A ........................................ .......................................... 0 ... Fire Safety Classification Type 1,Class C /0 ........................................ ..................... ...................._ Votage[V] Static Load Wind/Snow .2400Pa/5400Pa Current-voltage characteristics with dependence on irradiance ...................................... .......................................... 9 Pe Hail Safety Impact Velocity 25mm at 23 m/s and module temperature MECHANICAL DATA BASIC DESIGN (UNITS: mm) Solar Cells P-type Mono-crystalline Silicon (156.75mm) •x.00 XW 26.00 ....................... ........................................................... 2as6°— Cell orientation 60 cells(6x10) 4 busbar � ..................... ......................................................... 2e7m • �• 1664mm x 999mm x 40mm Module dimension nm (65.51 In.x 39.33 In.x 1.57 in.) + ....................... .................................... Weight 18.2 kg(40.1 Ib) ....................... ........................................................... Front Glass 3.2mm 0.126 in. tempered, ee 1 ..00 i ,•bpm Low-iron,Anti-reflective coating Hcole ................... ... ............................ Frame Anodized aluminum alloy ....................... ........................................................... •,a 00 Encapsulant Ethylene vinyl acetate(EVA) T' 460 ....................... ........................................................... 5m J-Box Protection class IP67 with 3 bypass-diodes ;�•.,�, 7m ....................... ........................................................... 726 -.--.m sa2m � Cables PV wire, 1 m(39.37 in.),4mm2/12 AWG _ ....................... ......... p .. .................................. Connector . MC4 or...com.... al..ible.. Front view sack view ,• )MISSION SOLAR �, ENERGY ' Mission Solar Energy reserves the right to make specification changes without notice. Rev.7.02 8303 •uth New Braunfels Ave. San Antonio TX 78235 missionsolar.cominfo@missionsolar.com1 .11 Data Sheet Enphase Microinverters Region:AMERICAS Enphase The high-powered smart grid-ready pEnphase IQ 7 Micro" and Enphase IQ 7+ Micro" IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery", and the Enphase Enlighten"" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing Class II double-insulated enclosure UL listed IQ Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements lie • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U *The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com � E N PHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/I0-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60 V Peak power tracking voltage 27 V-37 V 27V-45V Operating range 16 V-48 V 16V-60V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power - - 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208V/ 240V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(I07-60-2-US&IQ7PLUS 72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS 72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-525 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.Seethe compatibility calculator at ht a•// nphase.com/en-us/support/module-com atn ibMU. 2.Nominal voltage range can be extended beyond nominal if required bythe utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v E N P H AS E. 0E 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2010-05-24 Data Sheet Enphase Networking Enphase The Enphase IQ Combiner 3T" with Enphase IQ Combiner 3 IQ Envoy`" consolidates interconnection equipment into a single enclosure and (X-IQ-AM1-240-3) streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control _ Flexible networking supports Wi-Fi, Ethernet,or cellular Optional AC receptacle available for PLC bridge • Provides production metering and optional ttt consumption monitoring Simple • Reduced size from previous combiner Centered mounting brackets support single ` stud mounting Supports back and side conduit entry • +r Up to four 2-pole branch circuits for 240 VAC plug-in breakers(not included) -- -- - - — - 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure �` • Five-year warranty • UL listed LISTED ore about Enphase offerings,visit enphase.com E N P H A S E Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5°x)and optional*consumption monitoring(+/-2.5%). ACCESSORIES and REPLACEMENT PARTS (not included,order separately) Enphase Mobile Connect'" CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%) Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240 Circuit breaker,2 pole,1 SA,Eaton BR215 BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 EPLC-01 Power line carrier(communication bridge pair),quantity 2 XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC,60 Hz Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Max.continuous current rating(input from PV) 64A Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WXHXD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). Weight 7.5 kg(16.5 lbs) Ambient temperature range -40°C to+46°C(-401 to 115°F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMAtype 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional,802.3,Ca15E(or Cat 6)UTP Ethernet cable (not included) Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No. 107.1 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 *Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings,visit enphase.com v 2018 Enphase Energy.All rights reserved.All ttadernarks or brands in this document are registered bytheir respective owner E N P H AS E 2018-09-13 \� SnapNrack- UR=4^ Solar Mounting Solutions UR 60 Ti ie% U t i m a e 11 %A, in R*0%o if+L 0 saol. i, r Industry • • Wire • • - for ClampsMarvagc�nt Solutions- roof types Single Tool Installation All SnapNrack Module Accessories - compatible both • profiles Start Installing Ultra Rail Today RESOURCES snapnrack.com/resources DESIGN snapnrack.com/configurator WHERE TO BUY snapnrack,com/where-to-buy ,� �yy�?I__}.�RR •{ {' 7..; . W. .`., fix�. �f_,_ye,� ��p/R ��,�+�4.`4; �� '��j�I� "�� �iA Nr 0 oil Njp f IL Cf tj � r A Z F •Y. .c �, 'yam','#? '?�' . •;'f 'h9 i 3Al� '' r•A � r �N 3 � �, r ,W� j• rfM , � {� ]V�F:',n,,.`y !. .. ,yf �'. .X •'1fp 1 ��.y'�,�>E" � � .,` ;i '� 'ice,_ A`°�` �{f.M� `•'�� f A�;` +�,<�! f ,y . .f'c�.hlK`'�.= *,�B+�'...,v:•�?.., r.��s�If,, 'Y,;:"„' ^:.ti's;, IGA'. '�'' Vi �f►.�r.; �74'.i�+a..ra.r �A ���J°r14Q Wfa, Ap}� SnapNrack A sleek, straig-htforward rail sotUtjon for mounting solar modUtet--on all—eboUt-ypes. Ultra FZ811 features two rail profiles; UR-40 is a lightweight rail profile that is suitable for most geographic regions and ma ntains aff-We—great features of SnapNrack rail, while-UP 60 is a heavier duty rail 1 profile that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and-accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management %MW 010111111111W • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management offering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard Heavy Duty UR-60 Rail • UR-60 rail profile provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profile includes profile- specific rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience Qualityll-Innovative., Superior. SnapNrack Solar Mounting-..,Solutions are engill - . to . . use and labor resources and improve overall installation quality and safety. , • � `��• ` �*1Y, . � �* �r�,.A :x 4� + �4 r e�l' x. , 'y.,�1► �fla • ?� -� ,,,+. r � t", 1!' '� ttr " rJai't!d .t'M? Li�'i 0� r'•-�'k'� r 'f �°ry �1e Id' �� •� L y `�� � � f '� Hr;r 'ii � � � � •�.rr � � � �'!� 1�d� '. .� a�i> .."" r.� .`1 A,._r'R �' .Sr ! .8 1r,y. „�+ � •1�"Y s� y' �y v .I,! ! �, iii r y�'= •' + � }�°b"r°54 Ak hk r t Mrq"..tt'L ..E s i r .Y 'wb: .. t .._., :4. '?N, w 'i.N I.RY./'l11,.1 is ..Na ii� .t q. '�"�+i Ynps. -l:- `11Nrt�r r. .• � w. �eLa 1. .,rd+if nx 4ta.:¢LaBoa.. .:s..afts ,-ss. .. a-�. .re•,... .aa4.,t' ...•+Wt-a..:r*a.rr��+�a•rrL .t,R .-.esylrc-.a,.--.!r�^-•s:. �.Y•-.A .. ur'..t;.. •..tk. a�ats,�+. ._. � .. .,. .�... ..a. C Y t � s79Y�Yi! tY.QYwG#t ;: �•. /. � _���8s,�•, .,:,.i ��i+'��t'.�,',> i 1� �j � `v: Jl,.,�, t �.� • i tl jk,,_ � r C. �. r,M� N y b 4 �� ' '- ► { d9 N °,r !! ., en .4 ;�'ti iY: +: t Ki1T!„ .+7• }rNf: -a` D � -k+4 3 a i,,. . s f• + ..! 3 � `' � `�.' ! .��"• taN � �c... a q� x .Ya �1 ..A. •• k'�� ji t� •g ��� 6tlY � .L •w"L..��Yp.'4..,�•t+}•• h� *' �' "���� t ..i."'1° �'Rk. �`�f '� �.: t� N �' '� 4 a$t�'�c� � �•Y`� ti. C�y fi� ✓ � � � �f* ,a 1� L, A SUNMY INSTALLATION MADE E & 7 • EZ EZR SunModo' S best-selling EZ Roof Mount is the industry standard for PV system mounting on any composite . . . . - . . - shingle roof. • • - - . . . . • . . Now, SunModo introduces a smaller footprint, EZR Roof Mount flashing, where truss _ • anchoring can be assured, embossed design minimizes bending, and only one tool is needed. Key • - SUNM*N6I1FE3 T • MODEL EZ Mount EZR Mount 0 Raised teardrop design diverts water frorn the roof penetration. 360-clegree L foot positioning, serrated L foot on , , both sides • • A wide variety of L-feet and standoffs available. - - - - -- - - - - - - - - - - - - - - direct-to- decking foreasy Installation. Stamped emboss features stiffen the flashing to minimize bending. Only one tool is needed. Application Composite shingle Material High grade aluminum, 304 stainless steel hardware Finish Clear anodized, silver or black powder coated Flashing Size EZ Roof Mount: 10.00 x 12.48 x 0.04 inches EZR Roof Mount: 8.00 x 1 1 .38 x 0.03 inches Roof Attachment EZ Roof Mount: Rafter and decking EZR Roof Mount: Rafter only Structural Integrity IBC and IRC compliant Warranty 20 years SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com 1. -F•',' � f'it l7�� ,)tC 1 ,_, • .l t4l' ' 'f � f� i� • '�t r •.x t .. .'� .. !)l; .. .. !.t r 77 `r• %Att;r �t r r jhb� •�� YA� �Y 4+° v.G �r w f• r r, J � '�}. t � � .:Y�says 4 e.. , 4■■■'''{•!