Loading...
SOLAR PLANSCONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: 559-321-7000 info@advpermits.com GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSEDWRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLEALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONS ARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLYRECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDEDAND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJREQUIREMENTS. ASCE 7-10 WIND SPEED: MSP RATINGS COMBINER(S) AZIMUTH TILT N/A VB 9.450 KW PV-001 COVER SHEET Quinn, Nancy Steven Silverman 2015 National Grid 2015 82855812 2015 21134A (413) 584-8844 2020 Lilian Wanjiku 413-584-8844 City of Northampton 50507 Civil (202) 874-3483 swyssling@wysslingconsulting.com R-3 Risk Category II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook Dr Alpine, UT 84004 Quinn, Nancy 603 Fairway Village, Leeds, MA 01053 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 LG Electronics LG350N1C-V5 Enphase IQ7PLUS-72-2-US (240V) SnapNrack Ultra Rail UR-40 Snapnrack 242-01220 L Foot INTEGRATED IN INV N/A 27 27 N/A 61 27 N/A 1 (E) GPS LOCATION: (42.34461090000001, -72.6955255) 8.533 KW 3 120/240V - 1 9.5°,26.6° 190° ROOF COVERING MAX ARRAY HGT. 116 N/A Comp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS X-IQ-AM1-240-3 Enphase 200A BUS/200A MAIN BREAKER LINE-SIDE TAP 2015NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE:1/8"=1'-0"@ SHEET SIZE A3 3226 SECTION-1 111 14.29% 190 9.5°SECTION-1 190 26.6°SECTION-2 SECTION-3 190 26.6° 184 166SECTION-2 SECTION-3 QTY 27 LG Electronics LG350N1C-V5 MODULES QTY 27 Enphase IQ7PLUS-72-2-US (240V) INVERTER SCALE:1/8"=1'-0"@ SHEET SIZE A3 Rafters with interior supports 2"x8"@ 24" MAX OC Comp Shingle 2.67 PSF QTY 27 LG Electronics LG350N1C-V5 MODULES QTY 27 Enphase IQ7PLUS-72-2-US (240V) INVERTER A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 6:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 4’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS. PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 25' Comp Shingle MANUF TRUSS / TRUSS - PORTRAIT MANUF TRUSS / TRUSS - LANDSCAPE STANCHION DETAIL STANCHION SPACING DETAIL 12" 26.6°3" - 6" TYP 16.59" 33.19" 33.44" Ultra Rail UR-40 242-01220 L Foot L-Foot Flashing 12" 26.6°3" - 6" TYP 10" 20" 20.25" NOT USED ENGINEERED TRUSS ENGINEERED TRUSS ENGINEERING. ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" EMBEDMENT INTO FRAMING MEMBERS (E) ROOF SHEATHING /DECKING (E) FRAMING MEMBER L-FOOT PV MODULE, BY OTHERS MODULE END CLAMP SNAPNRACK ULTRA RAIL SNAPNRACK COMP UMBRELLA FLASHINGSSS HCS BOLT STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL NOT USED Eaton DG222URB NON-FUSIBLE DISCONNECT 120/240 60 2 3R 50.0 32.67 1 / &MATERIAL &MATERIAL AC COMBINER AC DISCONNECT (1) CU 75 #8 AWG 50 1.25 32.67 40.8 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 40.8 47.0 PRODUCTION METER (1) CU 75 #8 AWG 50 1.25 32.67 40.8 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 40.8 47.0 CIRCUIT BREAKER DISCONNECT (1) CU #8 AWG 50 1.25 32.67 40.8 INT/EXT WALL 35 N/A 0 AC COMBINER AC DISCONNECT PRODUCTION METER 75 35 0.94 3 1.0 50 0.94 1.0 47.0 40.8 47.0 CIRCUIT BREAKER DISCONNECT EXISTING SERVICE PANEL (1) CU 75 #8 AWG 50 1.25 32.67 40.8 INT/EXT WALL 35 N/A 0 35 0.94 1.0 0.94 1.0 47.0 47.035040.8 * 27 LG Electronics LG350N1C-V5 Enphase IQ7PLUS-72-2-US (240V) Soladeck RSTC 0799-5B Eaton DG222URB MA SMART GENERATION METER 120/240V - 1 NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER CEC/NEC 705.12(A) 27 1 3 0 1 1 0 1 0 EATON CH2L70RP 70A LOAD CENTER NEW MAIN SERVICE PANEL 1 200A BUS/200A MBEXISTING MAIN SERVICE PANEL 1 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT Enphase X-IQ-AM1-240-3 SCALE:1/8"=1'-0" @ SHEET SIZE A3QTY 27 LG Electronics LG350N1C-V5 MODULES QTY 27 Enphase IQ7PLUS-72-2-US (240V) INVERTER PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER YELLOW a FOR SOLAR PV SYSTEM RAPID SHUTDOWN SWITCH DO NOT DISCONNECT UNDER LOAD INVERTER # 1 PV SYSTEM DISCONNECT MAY BE UNGROUNDED AND ENERGIZED NORMALLY GROUNDED CONDUCTORS IF A GROUND FAULT IS INDICATED, ELECTRIC SHOCK HAZARD WARNING: OPEN POSITION SIDES MAY BE ENERGIZED IN THE TERMINALS ON BOTH LINE AND LOAD DO NOT TOUCH TERMINALS ELECTRIC SHOCK HAZARD WARNING: BE ENERGIZED SYSTEM ARE UNGROUNDED AND MAY CONDUCTORS OF THIS PHOTOVOLTAIC ELECTRIC SHOCK HAZARD. THE DC WARNING: QTY 27 LG Electronics LG350N1C-V5 MODULES QTY 27 Enphase IQ7PLUS-72-2-US (240V) INVERTER #3 #2 #1 AC COMBINER / DISCONNECT #3 AC SUB-PANEL #2 AC COMBINER / DISCONNECT #2 VOLTS AMPS AC NORMAL OPERATING VOLTAGE RATED AC OUTPUT CURRENT AC DISCONNECT PHOTOVOLTAIC SYSTEM VOLTS AMPS PV SYSTEM AC DISCONNECT AC NORMAL OPERATING VOLTAGE RATED AC OUTPUT CURRENT VOLTS AMPS AC NORMAL OPERATING VOLTAGE RATED AC OUTPUT CURRENT AC DISCONNECT PHOTOVOLTAIC SYSTEM VOLTS AMPSRATED AC OUTPUT CURRENT PV SYSTEM AC DISCONNECT AC NORMAL OPERATING VOLTAGE AC SUB-PANEL #1 AC COMBINER / DISCONNECT #1 [N/E/S/W] WALL OF BUILDING SYSTEM DISCONNECT LOCATED LOCATED BELOW. SOLAR PV UTILITY SERVICE DISCONNECT UTILITY, SOLAR PV SOURCES OF POWER: BUILDING CONTAINS TWO LOCATED [N/E/S/W] WALL OF BUILDING BELOW. SOLAR PV SYSTEM DISCONNECT UTILITY SERVICE DISCONNECT LOCATED OF POWER: UTILITY, SOLAR PV BUILDING CONTAINS TWO SOURCES VOLTS AMPS AC NORMAL OPERATING VOLTAGE RATED AC OUTPUT CURRENT AC DISCONNECT PHOTOVOLTAIC SYSTEM VOLTS AMPSRATED AC OUTPUT CURRENT PV SYSTEM AC DISCONNECT AC NORMAL OPERATING VOLTAGE VOLTS AMPS AC NORMAL OPERATING VOLTAGE RATED AC OUTPUT CURRENT AC DISCONNECT PHOTOVOLTAIC SYSTEM VOLTS AMPSRATED AC OUTPUT CURRENT PV SYSTEM AC DISCONNECT AC NORMAL OPERATING VOLTAGE MAY BE ENERGIZED IN THE OPEN POSITION TERMINALS ON BOTH THE LINE AND LOAD SIDES ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS WARNING VOLTS AMPS AC NORMAL OPERATING VOLTAGE RATED AC OUTPUT CURRENT DUAL POWER SOURCES WARNING VOLTS AMPS AC NORMAL OPERATING VOLTAGE RATED AC OUTPUT CURRENT AC DISCONNECT PHOTOVOLTAIC SYSTEM VOLTS AMPSRATED AC OUTPUT CURRENT PV SYSTEM AC DISCONNECT AC NORMAL OPERATING VOLTAGE 32.67 240 32.67 240 32.67 240 32.67 240 32.67 240 RACKING & RAIL CUT SHEET mwatkins . B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL FULL UR-60 RAIL CAPACITY N/A 12 LB-FT UL 2703, FILE E359313 0.71 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS11 SNAPNRACK, UR-60 SPLICE, SLEEVE, CLEAR / BLACK12 SNAPNRACK, O-RING13 SNAPNRACK, UR-60 SPLICE, BONDING BRIDGE14 1 4 3 2 RACKING & RAIL CUT SHEET RACKING & RAIL CUT SHEET RACKING & RAIL CUT SHEET RACKING & RAIL CUT SHEET mwatkins . B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 mwatkins . B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 1.00 4.20 .30 3.25 1.00 1.00 SLOT 1.50 2.78 1.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM .35 1.80 105° © 2016 Eaton. All rights reserved. ______________________________________________________________________No DataProduct compliance: UL Listed Certifications: Eaton Specification Sheet - DG222NRB Eatons Volume 2-Commercial Distribution Supporting documents: 240VVoltage Rating: General Duty Safety SwitchProduct Category: Three-wireNumber Of Wires: Two-poleNumber Of Poles: Fusible with neutralFuse Configuration: Class H fusesFuse Class Provision: Painted galvanized steelEnclosure Material: NEMA 3REnclosure: 60AAmperage Rating: General Duty/Cartridge FuseType: Specifications: of the Product, whichever occurs first. eighteen (18) months from the date of shipment the date of installation of the Product or Eaton Selling Policy 25-000, one (1) year from Warranties: a grounded B phase rating, UL listed. element fuses are used. 3-Phase hp rating shown is Maximum hp ratings apply only when dualNotes: 9 LBWeight: 8.4 INWidth: 6.41 INLength: 7 INHeight: Dimensions: 782113144221UPC: DG222NRB Safety Switch General Duty Cartridge Fuse pe.eaton.com