Loading...
SOLAR PLANSRELEASEREVDATE NAMEGOVERNING CODESPARCEL MAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVING JURISDICTION: BUILDING: CONTACT NAME: PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE:COVER SHEETSHEET SHEET TITLE EMAIL:APNdvancedSolarSolutions 39650Mallard BassLake,C93604 PHONE: 559-321-7000 EMAIL: info@advpermits.com ADDRESS ADDRESS kW PHOTOVOLTAIC PLANS PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSEDWRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLEALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDEDAND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJREQUIREMENTS. ASCE 7-10 WIND SPEED: MSP RATINGS COMBINER(S) AZIMUTH TILT DRIVEWY ℄MOUNTINST⅊ ⅊ ⅊ ⅊ NORTH N/A VB 7.260 KW PV-001 COVER SHEET Corwin, Julie Steven Silverman 2015 National Grid 2015 98716629 2015 21134A (413) 584-8844 2020 Lilian Wanjiku (413) 584-8844 City of Northampton Info@valleysolar.solar 50507 Civil (202) 874-3483 swyssling@wysslingconsulting.com R-3 Risk Category II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook Dr Alpine, UT 84004 Corwin, Julie 22 Mountain St, Florence, MA 01062 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 Hanwha Q-cells Q.PEAK DUO-G7 330 Enphase IQ7-60-2-US (240V) SnapNrack Ultra Rail UR-40 Snapnrack 242-01220 L Foot INTEGRATED IN INVERTER N/A 22 22 N/A 50 22 N/A 1 (E) COORDINATES: 42.3456376, -72.6695575 5.273 KW 2 120/240V - 1Φ 33.7° 236° ROOF COVERING MAX ARRAY HGT. 117 N/A Comp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS X-IQ-AM1-240-3 Enphase 200A BUS/200A MAIN BREAKER BACK FEED PV-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNGENERAL NOTES ADDRESS kW PHOTOVOLTAIC PLANS PJCT. SGYTSTHTTPPLYTTHS *LLTSSPPLCBLTTHSPJCT. CCTSSHLLBTFWTLCTS. BTTT.LLTCT3 XICICQUIPM,HBMLL STSBYLCSCTCT. GLBLGFGWKMSHP SLTFLSHGSWHQPC MWTHTGHTWTHPPVCHMCL SHLLBSLPIFPLLW :*WPFI .CMPLCWTH BSCWKMLKM WLLPVMDUCDUCCDUDY (A)()CMPLCWTH MYBFL-MKWHTPVWIBCKWI 4(B)WTH FSWTHGSYSTMSCMPLC .PVMLSWLSSHLLBLST3()() SPHTVLTC(PV)WCMPLC SHLLSCCTSLSTTFCICUI XPDUUDDDCPVUCDUPU 35(B)(3)(4)(c) SLGHTCCCWTH THSPCTVVMTCLGCT SPPLCBLTCDUCHBDD .8,7 CMPLCWTHCDUCHBIZD TPSZG. MMMCQMTSTLMT CCTSZSPCFCTSBSTH LCTSPSTSLGHT.CT FTHTPPSCLGWT IDCDUCHBPPVDCDU DUI:*WII&C UL(B)LSTLBLCCCWTH SHLLBULBCMPLCWTH BLGSWLLBC-FLTCCTPTCT GT.LLCPVCCTSSTLL WTHMMMSYSTMVLTGF80VLTS FLLPVSYSTMSPTTGBLG SQCFU(FCI)DCCICUIPCI PTCTCMPLCWTH ;BTHQVCTUUDD BHPIIVDIVDCPVCDUC .475,8,CMPLCWTH SHLLBCPDIDYPPCIFID 5(D) WHSCCTSQCMPLCWTH G.THF,BTHSHLLMP MBHPIIVDIVPVCDUC 5(A)SCCT CSCCT,TWHTSGHTFTHTLTYC WHTHVTSTJCTTTHTLTY SHLLBPVDDIICDICC 8P SCCT.FT,TTM3BTT TYP”KFBL“SHLLBCDICC CCSSBLTQLFTLTYPSL. VSBLBKTYPSWTCHWTHTLHL SHLLBLBL,LCKBL,FCDICC (TYPCLLYTHPPTMLS) PSHLLBTHTMLSMK,“LS” THTLLGZCCTSWHSCCTS WLLBCFGSICCIWICHD DCPD:*DICC STLLTSTCTS TSGLCPCCCWTHTH SHLLBCCTMICIVBCHCICUI 75(B)(5)FMTLFSTG FVTTPTSMPTBCKFDIBK 34 TCCCTSCMPLCWTH WTHSVC75(A)CMPLCWTH UPPYIDPICCI 75(B)()(3)(b) LSBSZPPPTLYSP THPPSTFTHBSBTSHLL THPVSYSTMBCK-FBKSHLLBSTLL 75(B)()()CMPLCWTH FDP(DID)ICCI 75(B)()(3)(c)CMPLCWTH CLGTHCPPTCTGTHBSB SHLLTCTHTMPCTYFTHBSB HIFCPDIDC 75(B)WTH CMPLC-IDICCID /PC:*ICCI 4(B)FUPCI DCUD-PVSYSTMSSHLLBPVWTH .AHJ5,47CMPLCWTH GGLCTSYSTMWLLBPV FSTGSYSTMSCCSSBLQT, .5THGH5547 CMPLSWTHHUDICDYM ML. TTPTGGCCTTTH GSCHTHTTHMVLFMLS SHLLBHUDICCIMDU QMTS. HLSPTHMFCT'SSTLLT MSTBSTLLTTHSPCFGGLG GGSTS,MLGGLGS PPVUL73STLLTML.F SHLLBSSTLLPMFCT'S MDUDCKUDIPPVU2703 .534AD53(A)CMPLCWTH CKG,CLSSSHLLBG CCTVPTSFMLFMS,ML .5 TABLCCTSSZCCCWTH MMMG43WTH CMPLCMPHBUDD MDUFMDHCLGPVQPMT 53(A) 534G,CMPLCWTH QPMTSTCTLCMPTSBT GGCCT.LLMTLLCTCL GQQPMT LYTHCCCTSDYMIUUD :*UDI CKGMFCTSGFC. TLBYTHMXPTHP-G LLPVCKGTTCHMTPTSSHLLTC WTHTHMFCTSTLLTSTCTS. SHLLBSTLLCCCUL73WTH LBLCCCSHLLBLSTFP &PVPMUDCKIYM :* DIIUCU PPLCBL. WHPUPDDFUDU IDFHIIDDLLCMPTS PPLCBLCS. CMPLCQUIFIDP CCIBLLQPMTSHLLBSTLL 5(A)SVCGSCCT. WHTHVTSTWTHSGHTFTHC SHLLBPVDDIICDICC() .34 STLLPVMLSCMPLCWTH PMTTTBDPUBXJUCI :* CI&CICQUIPM (A)-(D)WTH CTLSSPCFCPVCCTSCCC THTPIDHUDWFUCISHLLCL TSSTLLBLGPVSYSTMCC W:*PIDHUD QMTS. CLSSFCTSSALLUL,I,I 4ADSYSTMSCMPLCWTH CMBSTFLSTFSPV T,MLS,VTSSCCCT ;CLGBTTLMTPVYMCMP PVSPSCT STGPPSLCTCLQPMTWLLB DWKICCPPCC :*N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPN2015 IFC ROOF ACCESS REQUIREMENTS PV SITE LAYOUT LEGEND * EXISTING DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV ARRAY LAYOUTSQUARE FOOTAGE CALCULATIONS ROOF REFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH NDTILTTABLE SECTION #AZIMUTH ROOF PITCH / TILT EXISTING ROOF ADDRESS kW PHOTOVOLTAIC PLANSSECTION 1 ROOF ACCESS POINT SITE ACCESS GATE ACCESS SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALEAND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. . B. C. R R SECTION 1 NORTH PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE:1/4"=1'-0"@ SHEET SIZE A3 1050 SECTION-1 399 38 % 236 33.7°SECTION-1 QTY 22 Hanwha Q-cells Q.PEAK DUO-G7 330 MODULES QTY 22 Enphase IQ7-60-2-US (240V)PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESS* EXISTING ROOF DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKING LAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PV RAIL SPLICE 1 PV RAIL 2 PV RAIL SPLICE 2 RILTOROOF ATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURAL CONSTRUCTION ROOFING COVERING RACKING MAX PSF ROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING * DETAILS IN TOP VIEW SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP B. ANCHOR SPACING SHOWN IN DETAIL. UNLESS NOTEDOTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS. SEE "TABLE OF DIMENSIONS" EACH SECTION DETAILED FOR HORIZONTAL ANCHOR SPACING. C.SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENT MANUFACTURERS. ADDRESSAPN kW PHOTOVOLTAIC PLANSFRAMING INFO ROOF RACKING RAIL 29'-1012"11'-812" NORTH SCALE:1/4"=1'-0"@ SHEET SIZE A3 Rafter-Simple Attic 24" O.C. 2"x6"@ 24" MAX OC Comp Shingle 2.8 PSF QTY 22 Hanwha Q-cells Q.PEAK DUO-G7 330 MODULES QTY 22 Enphase IQ7-60-2-US (240V)S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 8:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 6’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND 21SCALE: NTS 3 4 .THESE NOTES APPLY TO RAFTER ROOF CONSTRUCTION. B.THE ROOF STRUCTURE CONFORMED TO BUILDING CODE REQUIREMENTS AT THE TIME IT WAS BUILT. C. STRAND BOARD OR PLYWOOD. 1X SKIP SHEATHING IS ACCEPTABLE. D.THE SOLAR ARRAY DISPLACES ROOF LIVE LOADS (TEMPORARY CONSTRUCTION LOADS) THAT THE ROOF WAS ORIGINALLY DESIGNED TO CARRY. E.IF THE ROOF COVERING IS SHINGLES; IT SHALL BE NO MORE THAN TWO LAYERS.(SHOWN) F.IF ROOF COVERING IS TILE; ITS A SINGLE LAYER. ALL TILES ON PLANE OF PV COMPONENTS ARE SECURE. (NOT SHOWN IN DETAIL) G.THE ROOF STRUCTURE IS STRUCTURALLY SOUND, WITHOUT SIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURAL DETERIORATION OR SAGGING. H.THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. I. AND THE ROOF SURFACE. (SEE TABLE OF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAY VARY FROM LISTED TABLES. STANCHIONS CAN BE PLACED NO CLOSER THAN 24" O.C. K. # SCALE: NTS SCALE: NTSSCALE: NTS SECTION ELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAIL TYPE 1 2 PV RAIL SPLICE TYPE 1 3 PV RAIL TYPE 2 4 PV RAIL SPLICE TYPE 2 5 STANCHION 6 FLASHING 7 MID CLAMP 8 END CLAMP EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEAN ROOF HGT MAX ROOFING COVERING TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS OH1 OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH RISE ROOF PITCH R2 RAFTER DEPTH THIS AREA H1 PV MODULE HGT. ABOVE ROOF HS1 HORIZONTAL SPAN HS2 HORIZONTAL SPAN UPSLOPE ANCHOR SPACING D1 RAIL OVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX. STANCHION O.C. * DETAILS IN SECTION OR SIDE VIEW ROOF RACKING RAIL SPLICE ROOFRCKING STANCHIONW/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSPER RAILMNUFCTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER MAX RAFTER SPANMAX RAFTER SPAN L. DETAILS SHOWN ARE A REPRESENTATION OF EXISTING ROOF CONDITIONS. ACTUAL FIELD CONDITIONS MAY VARY. DETAILS ARE SHOWN FOR DIAGRAM USE ONLY. REFER TO TABLES FOR DESIGN CRITERIA. ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTED BY PV MODULES AND EQUIPMENT. M. ROOF RACKING RAIL * IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV 1 D3 D2 D1 D2H1R2R1 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. * IF BLOCKING REQUIRED32 S-201 1 S-201 HORIZONTAL SPAN 12 RIDGE BEAM FRAMING 1 5 6 7 RISE 3 OH1HS1 PV 1 D3 D2 D1 D2H1R2R1 ** COMP SHINGLE ROOF IN EXAMPLE. SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 (E) FRAMING @ 24" O.C. TYPICAL 2'-0" TYP. 4'-0" MAX SIMPLE ATTIC / RAFTER - PORTRAIT SIMPLE ATTIC / RAFTER - LANDSCAPE STANCHION DETAIL STANCHION SPACING DETAIL Ultra Rail UR-60 242-01220 L Foot L-Foot Flashing 8" 33.7° 3" - 6" TYP 9.85" 19.7" 19.95" N/A 6" 11'-1'' 8" 33.7° 3" - 6" TYP 16.58" 33.15" 33.4" N/A 6" 11'-1'' 25' Comp Shingle NOT USED 11'-9" MAX 11'-9" MAX S-200Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT SHEET NOTES RELEASEREVDATE NAME ADDRESSAPNPV RACKING LEGEND * DETAILS IN SECTION OR SIDE VIEW 1.(1) ENGINEERING. 2.ADHERE TO RACKING MANUFACTURERS INSTALLATION INSTRUCTIONS PERTAINING TO CANTILEVER. 21SCALE: NTS 3 4 SCALE: NTS SCALE: NTSSCALE: NTS ATTACHMENT DETAILSROOF RACKING RAIL SPLICE ROOF RACKING STANCHION W/ RETRO FIT FLASHING SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP ADDRESS kW PHOTOVOLTAIC PLANSROOF RACKING RAIL ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" EMBEDMENT INTO FRAMING MEMBERS (E) ROOF SHEATHING /DECKING (E) FRAMING MEMBER L-FOOT PV MODULE, BY OTHERS MODULE END CLAMP SNAPNRACK ULTRA RAIL SNAPNRACK COMP UMBRELLA FLASHINGS5/16”-18X2-1/4” SS HCS BOLT 1/3" OF TOTAL SPAN MAX 2/3" OF TOTAL SPAN MAX RAIL MANUFACTURER RAIL SPLICE KIT SEE "S-100 / TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE. SEE SHEET "S-100" FOR: HORIZONTAL ANCHOR SPAN SPACING. (E) FRAMING TYPICAL * MODULES SHOWN PORTRAIT IN EXAMPLE DC AND/OR 1/3 CANT. MAX COMPONENT + 2" FROM SIDE OF MODULE 2" ROOF TOP CONDUIT EXTENSION OF RAIL RAIL OR STRUT CONNECTIONS TO MEET WEIGHT REQ. OF EQUIPMENT DCB * MODULES SHOWN PORTRAIT IN EXAMPLE ** RAILING SHOWING IN VERTICAL IN EXAMPLE RIDGE BEAM *R2*R1VERIFY THAT NO DIAGONAL AND/OR VERTICAL ATTIC/FRAMING STRUT MEMBERS ARE CUT OR NOTCHED * SEE DETAILS "1-2/S200" TABLE OF DIMENSIONS HOLES ALLOWED ONLY IN MIDDLE HALF OF FRAMING SPAN 1/4 1/4 HOLES ALLOWED ONLY IN MIDDLE THIRD OF FRAMING DEPTH, *R2, AND NO LARGER THAN *R2/4 IN DIAMETER. MINIMUM SPACING BETWEEN HOLES AT *R2 FRAMING SAG IN INCHES NOT TO EXCEED FRAMING LENGTH IN FEET DIVIDED BY 20 NOTCHES DEEPER THAN 1/4" NOT ALLOWED ALONG TOP OR BOTTOM EDGE OF FRAMING NOTE: WHERE FRAMING IS VISIBLE FROM ATTIC &/OR UNDERSIDE OF ROOF, VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURAL DECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. RIDGE SAG IN INCHES NOT TO EXCEED RIDGE LENGTH IN FEET DIVIDED BY 20 STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL RAFTER HOLE AND CONSTRUCTION DETAIL S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CALCULATIONSPV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/ EXPEDITED-PERMIT/MAP/ EXTREME MIN. STC TEMPERATURE CORRECTED TEMPERTURE MFR. PMAX TEMP COEFFICIENT [-0.#%/C] * 100 FORMULA CORRECTED TEMP. COEFFICIENT MODULE Voc [VDC] TEMPERATURE CORRECTED OPEN CIRCUIT VOLTAGE -=*+=*= PV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L" x W" x D"/THICK PEAK POWER @ STC (Pmax)WATTS Voc (OPEN-CIRCUIT VOLTAGE)VOLTS DC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUIT CURRENT)AMPS imp (SHORT-CIRCUIT POWER)AMPS MFR. Voc TEMP COEFFICIENT %/K MAX SERIES FUSE RATING AMPS TEMP. CORRECTED Voc VOLTS DC AC COMBINER (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING MAIN BREAKER SIZE TOTAL INPUT CURRENT AMPS NUMBER OF BRANCH CIRCUITS AMPS CIRCUITS AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS PV BACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSS BAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS (Imax) AC SUB-PANEL #2 (IF APPL.) NEW OR EXISTING MAKE / MODEL TYPE OF PANEL NUMBER OF POLES P NEMA RATING BUSS BAR RATING AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C. BREAKER AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLAR CURRENT AMPS AMPS (Imax) AMPS (Imax) MICRO INVERTER #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs. DC INPUT Max PV POWER @ MODULE STC WATTS Max INPUT DC VOLTAGE VOLTS DC Max INPUT CURRENT AMPS MODULES PER MICRO INVERTER QTY AC OUTPUT NOMINAL VOLTAGE OUTPUT VOLTS AC MAX OVERCURRENT PROTECTION (OCPD)AMPS MAX. OUTPUT CURRENT AMPS - MAX ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECT DEVICE TYPE RATED OPERATIONAL VOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSE RATING AMPS TOTAL INPUT CURRENT QUANTITY AC DISCO.(S) PV BACKFEED BREAKER #2 PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 AMPS (Imax) SUM OF EXISTING CIRCUIT BREAKERS MAX ALLOWABLE SOLAR CURRENT 100% MAX ALLOWABLE SOLAR CURRENT 120% PV BACKFEED BREAKER #1 PV BACKFEED BREAKER #2 ALT. ENERGY BACKFEED BREAKER (IF APPL.)AMPS (Imax) Hanwha Q-cells Q.PEAK DUO-G7 330 39.4 66.3 x 39.4 x 1.26 330 40.62 34.14 10.15 9.67 -0.27 20.0 Enphase IQ7-60-2-US (240V) 240 2.38 240 48 15.0 1 240 20 1 Enphase X-IQ-AM1-240-3 240 125 2 3R N/A 22 2 Eaton DG222URB NON-FUSIBLE DISCONNECT 120/240 60 2 3R N/A 22 EXISTING 120/240V Single Phase 200 200 0 40 30 -20 25 -45 -0.27%0.12 1 1.12 40.62 45.49 45.49 1 E-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNDC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUIT CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILL DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMP RATING TRADE SIZE AMPACITY PER 310.16 MAX CURRENT 690.8 (A)(1) CONT. OPERATION 690.8 (B)(1) REQUIRED AMPACITY CIRCUIT ENVIRONMENT MBIENT TEMP. HGT. ABOVE ROOF (in) TEMP. ADDER PER 310.15 (B)(2)(c) OPERAT. TEMP. AMPACITY CORRECTION 310.15 (B)(2)(a) # OF UNGRND. COND. AMPACITY CORRECTION 310.15 (B)(3)(a) COND. AMPACITY TEMP. DERATING CONDUIT FILL DERATING XXX=XX=CORRECTED AMPACITY REQUIRED AMPACITY <CORRECTED AMPACITY DC1 XXX=XX=<WIRE AND COND. CALCS.1. ANY CONDUCTOR LENGTH UNDER 50' DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED. 3. WIRE COLOR CODING (2020) CEC/NEC SECTIONS 250.119 & 200.6 PV DC WIRING AC WIRING 2.BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS; WORST CASE SCENARIOS, ROUNDING UP SIZES OF CONDUCTORS THAT AREEQUIPMENT GROUNDGREEN OR BARE, OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE, OR GREEN/YELLOW TYPICALLY NEGATIVEWHITE OR GRAY(NEUTRAL)WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITE OR GRAY UNGROUNDED CONDUCTOR(S). TYPICALLY POSITIVE ANY COLOR OTHER THAN GREEN OR WHITE/GRAY UNGROUNDED L1 AND L2 ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. CONVENTION IS RED FOR GROUNDED SYSTEMSCONDUCTOR(S) HOT:CONVENTION IS L1 BLACK RED (+) AND BLACK (-) FOR UNGROUNDED SYSTEMSCONVENTION IS L2 RED WIRE AND CONDUCTOR NOTES ADDRESS kW PHOTOVOLTAIC PLANSWHEN LESS THAN 10'-0" OR 10% OF THE CIRCUIT LENGTH; THE LESSER AMPACITY MAY BE USED. USED BEYOND THE POINT OF TRANSITION, A DISTANCE EQUAL TO 10'-0" (3 METERS) OR 10% OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY, WHICHEVER IS LESS. 4.CEC/NEC 310.15(A)(2) (AS APPLICABLE) WHERE TWO DIFFERENT AMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT, THE HIGHER AMPACITY SHALL BE PERMITTED TO BE AC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUIT DESTINATION CONDUCTOR SPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILL DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMP RATING TRADE SIZE AMPACITY PER 310.16 CONT. OPERATION 690.8 (B)(1) X =REQUIRED AMPACITY CIRCUIT ENVIRONMENT MBIENT TEMP. HGT. ABOVE ROOF (in) TEMP. ADDER PER 310.15 (B)(2)(c) OPERAT. AMPACITY CORRECTION 310.15 (B)(2)(a) # OF UNGRND. COND. AMPACITY CORRECTION 310.15 (B)(3)(a) COND. AMPACITY X TEMP. DERATING X CONDUIT FILL DERATING =CORRECTED AMPACITY REQUIRED AMPACITY <CORRECTED AMPACITY AC1 X =X X =< AC2 X =X X =< AC3 X =X X =< AC4 X =X X =< AC5 X =X X = AC6 X =X X =< AC7 X =X X =< AC8 X =X X =< AC9 X =X X =< AC10 X =X X = < < #OF COMBINED PARALLEL CIRCUITS QTY IN PARALLEL &MATERIAL QTY IN PARALLEL &MATERIAL DESTINATION MAX INV. OUTPUT CURRENT (AMPS) OR COMPONENT (AMPS) lsc (AMPS) OR COMPONENT (AMPS) PV MODULE INVERTER (1) CU 90 #12 AWG 30 10.15 1 1.25 1.25 15.9 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 15.9 28.8 INVERTER JUNCTION BOX (1) CU 75 #12 AWG 25 1.25 11 13.8 ROOFTOP 35 >7/8"0 35 0.94 4 N/A 25 0.94 1.0 23.5 13.8 23.5 AC COMBINER (1) CU 75 #10 AWG 35 1.25 11 13.8 ATTIC 35 IN ATTIC 22 57 4 N/A 350.58 0.58 1.0 20.3 13.8 20.3 AC DISCONNECT (1) CU 75 #10 AWG 35 1.25 22 27.5 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 35 0.94 1.0 32.9 27.5 32.9 PRODUCTION METER (1) CU 75 #10 AWG 35 1.25 22 27.5 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 35 0.94 1.0 32.9 27.5 32.9 EXISTING SERVICE PANEL (1) CU #10 AWG 35 1.25 22 27.5 INT/EXT WALL 35 N/A 0 JUNCTION BOX AC COMBINER AC DISCONNECT PRODUCTION METER 75 35 0.94 3 1.0 35 0.94 1.0 32.9 27.5 32.9 E-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT LEGEND RELEASEREVDATE NAME ADDRESSDC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC#THREE LINE DIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PV MODULES 2 MICRO INVERTER 3 AC COMBINER BOX 4 JUNCTION BOX 5 NEW SOLAR LOAD CENTER 9 AC DISCONNECT (FUSIBLE) 7 PROD/GENERATION METER 8 SUB PANEL 10 NEW MAIN SERVICE PANEL 11 EXISTING MAIN SERVICE PANEL 12 EXISTING UTILITY METER GROUND CONDUCTOR TAGGND ELECTRICAL NOTES TAG APN ADDRESSBRANCH MODULE QTY OCPD BACK-FEED SOLAR BREAKER: CONDUCTOR TABLE TAG QTY*SIZE TYPE DC1 AC1 AC2 AC3 AC4 AC5 GROUND CONDUIT TABLE SIZE TYPE AC6 •INTEGRATED MICRO INVERTERS (AC MODULES) MUST BE CERTIFIED UL1742 AND UL1703 COMPLIANT. AS EITHER INDIVIDUAL COMPONENTS OR AC MODULE ASSEMBLY. THEY MUST ALSO BE LABELED "UTILITY INTERACTIVE" CONFORMING TO IEEE1547 TESTING. •PV MODULES THAT HAVE INVERTERS ATTACHED WITHOUT AN AC MODULE EVALUATION BY A NRTL MAY VIOLATE THE ORIGINAL LISTING OF THE PV MODULE AND VOID THE WARRANTY OF THE MODULE. •VERIFY MODULE IS COMPATIBLE WITH MICRO INVERTER MANUFACTURER AND MODEL. •ARTICLE CEC/NEC 690 STILL APPLIES. THE INSTALLER WILL NEED TO CONSIDER REQUIREMENTS SUCH AS: DC GROUND FAULT DETECTION AND INTERRUPT, DC CABLE MANAGEMENT, DC DISCONNECTING MEANS AND DC GROUNDING AS WELL AS THE AC EQUIPMENT GROUNDING CONDUCTOR TO THE INVERTER. BACKFEEDING. NEC INFORMATIONAL NOTE: FUSED DISCONNECTS, UNLESS OTHERWISE MARKED, ARE SUITABLE FOR BACKFEEDING. •690.13(F)(2) DEVICES MARKED WITH "LINET BEPERMITTEFRBCKFEERREVERECURRET •705.12(B)(5) CIRCUIT BREAKERS BACK FEED FROM UTILITY INTERACTIVE INVERTERS (ANTI-ISLANDING, UL 1741 CERTIFIED) •ALL OVERCURRENT PROTECTION DEVICES (OCPDs) MUST BE RATED FOR 600 VOLTS ON THE DC / PV POWER SIDE OF THE INVERTER. •ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FOR WET AND DAMP LOCATIONS WHEN APPLICABLE. INTERCONNECTION NOTES: •705.12(B)(4) CIRCUIT BREAKERS MUST BE SUITABLE FOR kW PHOTOVOLTAIC PLANSAC7 AC9 AC10 AC8 6 AC DISCONNECT AT GROUND LEVEL SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS NOTE: EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER, N/A USED * INCLUDES GROUND & CURRENT CARRYING CONDUCTORS • INVERTER NAMEPLATE RATING 330W/240V MODULE NAMEPLATE RATING 330W L2 L1 G BUS RATING 3 AC3 125A L2L1 G N ENVOY-IQ FOR MONITORING GEC N (-)(+) (-)(+) AC DC AC DC 2 2 11 MODULES 1 1 11 MODULES (+) (+) 2 2 AC DC(-) (-)DC AC 1 1 DC1 EGC AC1 15A G G L1 L1 L1 L1 L2 L2 L2 L2 L1 L1 L2 L2 AC2 15A 4 10A L2 L1 G N L2 L1 G N 6 N G L2 L1 PV N G L2 L1 7 AC4 EGC AC5 30A READILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT VISIBLE FROM APPROACH TO RESIDENCE 60A 240V LOCATED EXTERIOR ON WALL NEAR METER NEMA 3R TOP LUGS TO UTILITY (LINE) BOTTOM LUGS TO SOLAR GENERATION (LOAD) LOCATED EXTERIOR MA SMART GENERATION METER NOTE: CONDUCTORS AC3,AC4 & AC5 MAY BE THWN-2 OR SER CABLE ()PVSTRINGS(L/LSHOWN)OFMODULES M 12 G N BUS RATING 11 MAIN C/B RATING GEC 200A 200A 22 Hanwha Q-cells Q.PEAK DUO-G7 330 Enphase IQ7-60-2-US (240V) Soladeck RSTC 0799-5B Eaton DG222URB MA SMART GENERATION METER 1 11 15A 200A BUS/200A MB 2 11 15A 120/240V - 1ф #12 AWG PV Wire Open Air 30A NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER CEC/NEC 705.12(B)(2)(3)(b) 22 1 1 0 1 1 0 0 0 1 1 2 #6 AWG N/A 5 #12 AWG TRUNK CBL #6 AWG N/A Open Air 5 #10 AWG NM-B #10 AWG N/A Open Air 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT 4 #10 AWG THWN-2 #8 AWG 1/2 inch EMT Enphase X-IQ-AM1-240-3 E-003Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNELECTRICAL SYMBOL LEGEND SECTION 1 PV ARRAY TAG SECTION # MODULE GROUP AC DISCONNECT PERFORMANCE METER UTILITY METER JUNCTION BOX AC P M ELECTRICAL LAYOUTEQUIPMENT GROUNDING 1. METAL PV MODULE FRAMES NEED TO BE CONNECTED TO THE EGC (EQUIPMENT GROUNDING CONDUCTOR). 1.1. WEEBS MAY BE USED IN LIEU OF MODULE GROUND CLAMPS OR LUGS, WITH APPROVAL OF AHJ AND RACKING MFG. WEEBS ARE ONE TIME USE ONLY. SEE "we-llc.com" FOR RACKING SPECIFIC WEEB, INSTALL INSTRUCTIONS, AND UL 2703 CERT. 1.2.FOR "LAY-IN" LUG MODULE GROUNDING; CORRECT HARDWARE OF PROPER METAL MATERIAL TO AVOID CORROSION MUST BE USED. TYPICALLY DIRECT BURIAL RATED, TINNED, OR STAINLESS STEEL. GROUNDING LUGS MUST BE ATTACHED AT MARKED LOCATION ON EACH MODULE. 2. THE EGC (EQUIPMENT GROUNDING CONDUCTOR) IS USED TO BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSED METAL PARTS THAT MIGHT COME INTO CONTACT WITH CURRENT-CARRYING CONDUCTORS, INCLUDING THE FOLLOWING: 2.1. PV MODULES FRAMES, ARRAY MOUNTING RACKING; THE METAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS, DISCONNECTS, METERS, JUNCTION BOXES AND COMBINER BOXES; AND METAL CONDUIT HOLDING CIRCUITS > 250 VOLTS TO GROUND PER NEC 250.97 3. THE GEC (GROUNDING ELECTRODE CONDUCTOR) IS THE CONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THE SYSTEM GC, TO THE EGC, OR TO BOTH. 4. THE GE (GROUNDING ELECTRODE) IS A CONDUCTING OBJECT, OFTEN A ROD, RING, OR PLATE ESTABLISHING A DIRECT CONNECTION TO EARTH. THE AC SYSTEM GROUND IS EXISTING, USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BE DUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. SERVICE PANELSP ADDRESS kW PHOTOVOLTAIC PLANSAUTO TRANSFORMERATF SOLAR LOAD CENTER BATTERY SLC AC COMBINERACC BATT CLP CRITICAL LOADS PANEL JB XFMR TRANSFORMER SUB-PANELSUB C SP M CC P JB NORTH SCALE:1/4"=1'-0"@ SHEET SIZE A3QTY 22 Hanwha Q-cells Q.PEAK DUO-G7 330 MODULES QTY 22 Enphase IQ7-60-2-US (240V) PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER E-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSTANDARD PLACARDS ADDRESS kW PHOTOVOLTAIC PLANSSHEET NOTES1SCALE: 1/2" = 1'-0"CONDUIT, RACEWAY, J-BOX, AND PULL BOXES 2 3 5 6 8 SCALE: 1/4" = 1'-0"9 10 4 1.PLACE ON CONDUIT AND/OR RACE WAYS EVERY 10' (60"), 12" FROM BENDS, 12" ABOVE AND BELOW PENETRATIONS. 2.CODE REFERENCE: NEC 690.31(G)(3) 3.MINIMUM OF 1 1/8" x 5 3/4" 4.FONT: 3/8" AND .8 WIDTH FACTOR. 5.REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. J-BOX, DC COMBINER, AND DC DISCONNECT WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED SCALE: 1/4" = 1'-0" 1.ONLY FOR UNGROUNDED SYSTEMS. 2.PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITS OR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSED DURING SERVICE. 3.MINIMUM OF 3" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. NON-LOAD BREAK DC COMBINER / J-BOX WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION SCALE: 1/2" = 1'-0" 1.PLACED ON DC DISCONNECT(S) AND ON ANY EQUIPMENT THAT STAYS ENERGIZED IN THE OFF POSITION FROM THE PV SUPPLY. 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 3 1/2" x 10" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. INVERTER(S)SCALE: 1/2" = 1'-0" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED 1.A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN 1M (3 FT) FROM THE SWITCH THAT INCLUDES THE FOLLOWING: 2. 3. MINIMUM OF 3 1/2" x 10 1/2" 4. FONT: 3/8" WHITE LETTERS ON A RED BACKGROUND. AC AND DC DISCONNECTS PV SYSTEM DISCONNECT 1.PLACE ON ALL AC AND DC DISCONNECTS 2.CODE REFERENCE: NEC 690.13(B) 3.MINIMUM OF 1" x 10 1/2" 4.FONT: 3/8" 5.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" DC COMBINER BOX 1. 2. USE PLACARD "COMBINER # 1" WHEN MORE THAN 1 DC COMBINER IS USED. NUMBER ACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1" x 4" 4. FONT: 3/8" AND .75 TO .8 WIDTH FACTOR WHITE LETTERS ON A RED BACKGROUND. 1.CODE REFERENCE: NEC 690.13(C) 2.USE ON NON-LOAD BREAK RATED DISCONNECTION. 3.MINIMUM OF 1" x 6" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. DC DISCONNECTS 1.USE PLACARD ON CUSTOMER GENERATION METER. 2.VERIFY WHICH PLACARD IS REQUIRED WITH AHJ. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .8 WIDTH FACTOR 5.WHITE LETTERS ON A RED BACKGROUND. SOLAR kWh METER SCALE: 1/2" = 1'-0" INVERTER # 1 1.USE PLACARD "INVERTER # 1" WHEN MORE THAN 1 INVERTER IS USED. NUMBER ACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 2.MINIMUM OF 1" x 4" 3.FONT: 3/8" 4.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2" = 1'-0"INVERTER'S USE PLACARD "[AC][DC] DISCONNECT # 1" WHEN MORE THAN ONE DISCONNECT IS USED. NUMBER ACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 11 SCALE: 1/4" = 1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE PLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROMTHE MULTIPLE PLACARDS MUST BE PRESENT. 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN PLACE OF THE STANDARD WHITE LETTERS WITH RED BACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.13 & 690.53) 4.THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. (IFC 605.11.1.4, NEC 690.31[G][3] ) 5.WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING. UL LISTING OF MARKINGS ISNOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIAL OR SIMILAR FONT, NON-BOLD. 7.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 7.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 7.4.CONTRASTING BACKGROUND AND LETTERING. 7.5.ALL CAPITAL LETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 7.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVED MANUFACTURED PRODUCT CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL) DO NOT DISCONNECT UNDER LOAD 7 RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM AND HAVING A MINIMUM HEIGHT OF 9.5 MM (3 TEOREDBACKGROUD 2. 1/4" = 1'-0" SCALE: 90.5()(1)(a .3/8"BACKCHARACRSOYELLOW BACKGROUD,RAGCHARACRS.3/16" BACKOWHBACKGROUD. LATMTHA1mFROHSRVCDSCO MASTWHIHTHPVSYSTMSATA SHALLIIATTHLATIALLITIIAPI SHUTWSWITHSITATTHSAMLATI. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS THE LABEL SHALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZED P-001QTY 22 Hanwha Q-cells Q.PEAK DUO-G7 330 MODULES QTY 22 Enphase IQ7-60-2-US (240V)Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNSHEET NOTES123 4 SCALE: 1/4" = 1'-0" MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE: 1/4" = 1'-0"UTILITY METER, SERVICE PANEL, SUB-PANELAC DISCONNECT, AC SUB-PANEL 1.PLACARD PLACED ON EACH SOLAR SYSTEM DISCONNECTING COMPONENT. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. SEE SHEET "E-001 / AC DISCONNECT [#]" 3.CODE REFERENCE: NEC 690.54 4.MINIMUM OF 1 1/2" x 8 1/2" (TOP), 1 3/4" x 6 1/2" (BOT) 5.FONT: 3/8" HEADER, 3/16" DATA 6.WHITE LETTERS ON A RED BACKGROUND. AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1) PLACARD PLACED AT MAIN UTILITY SERVICE DISCONNECT/BREAKER AND PV SYSTEM SUPPLY BREAKER AT POINT OF INTERCONNECTION. (#2 & #3) PLACARD(S) REQUIRED WITH #1 PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT ARE NOT LOCATED NEXT TO EACH OTHER. MAP PLACARD REQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER INVERTERS. IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS; SEE SHEET "E-001 / STRING INVERTER[#] SPECIFICATIONS". 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. 2.1.2."RATED AC OUTPUT CURRENT" WILL BE THE SUM OF THE INVERTERS 2.1.3."AC NORMAL OPERATING VOLTAGE" WILL BE THE NAME PLATE RATING OF THE INVERTER 3.CODE REFERENCE: NEC 690.54, NEC 705.12(D)(3) 4.MINIMUM OF 2" x 6 1/2" (#1), VARIES (#2 & #3) 5.FONT: 3/8" HEADER, 3/16" DATA (#1), 1/4" (#2 & #3) 6.WHITE LETTERS ON A RED BACKGROUND. SCALE: 1/2" = 1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAP PLACARD: MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAME LOCATION) SCALE: 1/2" = 1'-0" CAUTION AC COMBINER DYNAMIC PLACARDSAC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING SCALE: 1/2" = 1'-0" 1.CODE REFERENCE: NEC 690.16(B) AND NEC 690.17 2.USE PLACARD "COMBINER # 1" WHEN MORE THAN 1 AC COMBINER IS USED. NUMBER ACCORDING TO THREE LINE DIAGRAM AND CALCULATIONS. 3.MINIMUM OF 1" x 4" 4.FONT: 3/8" AND .75 TO .8 WIDTH FACTOR MINIMUM. 5.WHITE LETTERS ON A RED BACKGROUND. 6.PLACARDS MAY BE COMBINED TOGETHER. I.E. "AC COMBINER BOX #1". MINIMUM REQUIREMENTS LISTED ABOVE. AC COMBINER / DISCONNECT #1 AC SUB-PANEL #1 AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC COMBINER / DISCONNECT #2 AC SUB-PANEL #2 AC COMBINER / DISCONNECT #3 ADDRESS kW PHOTOVOLTAIC PLANS#1 #2 #3 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PV INVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICE DISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 6 1/2" x 6 1/2" 6.FONT: 3/4" "CAUTION", 1/4" HEADER, 1/8" DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAINSERVICE DISCONNECT IN A LOCATION CLEARLYVISIBLE FROM WHERE THE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRC R331.2.3) 1.PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PV INVERTER AND PV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES A DIRECTORY OF THE SERVICE DISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE: NEC 690.56(A)(B), 705.10 4.WHITE LETTERS ON A RED BACKGROUND. 5.MINIMUM OF 7 3/4" x 5" 6.FONT: 3/4" "CAUTION", 1/4" "WARNING", 3/16" HEADER, 1/8" DATA AND NOTES 7.PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERE THE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRC R331.2.3) 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE PLACARDS FOR THE SAME DEVICE. ALL INFORMATION FROM THE MULTIPLE PLACARDS MUST BE PRESENT. 2. 3. 4. BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN PLACE OF THE STANDARD WHITE LETTERS WITH RED BACKGROUND WITH AHJ APPROVAL. ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (NEC 690.31[G], NEC 690.53) REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT. UL STANDARD IS RECOMMENDED TO DETERMINE WEATHER RATING. UL LISTING OF MARKINGS IS NOT REQUIRED. SEE UL LABELING SYSTEM 969 (UL 969) 5.MARKING CONTENT AND FORMAT: 5.1.ARIAL OR SIMILAR FONT, NON-BOLD. 5.2.MINIMUM 3/8" LETTER HEIGHT FOR HEADERS. 5.3.MINIMUM 1/16" LETTER HEIGHT FOR DATA 5.4.CONTRASTING BACKGROUND AND LETTERING. 5.5.ALL CAPITAL LETTERS. 5.6.CONTRASTING SPACE BETWEEN ROWS OF TEXT 5.7.DIMENSIONS OF PLACARDS ARE APPROXIMATE. MAY BE REDUCED AND / OR INCREASED TO UL APPROVED MANUFACTURED PRODUCT 6.ANSI Z535.4-2014 PRODUCT SAFETY SIGNS AND LABELS: THIS INFORMATIONAL NOTE AND ITS REQUIREMENTS FOR MAY BE USED WITH PRIOR APPROVAL OF THE AHJ.MOST NOTABLE DIFFERENCES IS COLOR OF PLACARDS AND USEOF HAND WRITTEN VALUES WITH INDUSTRIAL MARKERS ON STANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT A FUTURE DATE. I.E. ADDING MODULES AT A FUTURE DATE, OR STANDARD PLACARD MANUFACTURER INSTALLED ON ELECTRICAL COMPONENT. AHJ APPROVAL REQUIRED. (SEE NOTE #1 FOR INDIVIDUAL PLACARDS) CODE ABBREVIATIONS: NATIONAL ELECTRICAL CODE (NEC) INTERNATIONAL BUILDING CODE (IBC) INTERNATIONAL RESIDENTIAL CODE (IRC) INTERNATIONAL FIRE CODE (IFC) UNDERWRITERS LABORATORY (UL) (E)UTILITYMETER &SERVICEPNEL CDISCO CCOMBINER SOLARARRAY ONROOFTOP SOLARARRAY ONROOFTOP PRODUCTION METER (E)UTILITYMETER &SERVICEPNEL CDISCO CCOMBINER PRODUCTION METER N N 22 240 22 240 22 240 22 240 22 240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achievingthehighestsystemefciency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate seamlessly with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warrantyofupto25years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Congurableforvaryinggridproles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com ©2018EnphaseEnergy.Allrightsreserved.AlltrademarksorbrandsusedarethepropertyofEnphaseEnergy,Inc. 2018-05-14 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings¹235 W - 350 W +235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc)15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PVarrayconguration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range²240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A 1.15 A 1.21 A 1.39 A Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable)0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V PeakCECefciency 97.6 %97.6 %97.5 %97.3 % CECweightedefciency 97.0 %97.0 %97.0 %97.0 % MECHANICAL DATA IQ 7 Microinverter Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSsnapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience RACKING & RAIL CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSDESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-60RAIL 232-02481,232-02482,232-02483 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANY REPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHE WRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USA PHONE(415)580-6900●FAX(415)580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 8.46 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 120 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-60 RAIL PROPERTIES SKU FINISH 232-02481 MILL 232-02482 CLEAR 232-02483 BLACK CENTROID .750 1.211 1.039 SECTION PROPERTIES A 0.515 in² Ixx 0.327 in⁴ Iyy 0.181 in⁴ Sx (TOP)0.270 in³ Sx (BOT)0.315 in³ Sy (LEFT)0.242 in³ Sy (RIGHT)0.242 in³ 2.250 1.500 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-60 SPLICE 242-01270, 242-01271 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL FULL UR-60 RAIL CAPACITY N/A 12 LB-FT UL 2703, FILE E359313 0.71 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS11 SNAPNRACK, UR-60 SPLICE, SLEEVE, CLEAR / BLACK12 SNAPNRACK, O-RING13 SNAPNRACK, UR-60 SPLICE, BONDING BRIDGE14 1 4 3 2 RACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSsnapnrack.com 51 System Bonding Methods Grounding Specications RAIL CHANNEL NUT MODULE FRAME MID CLAMP ASSEMBLY SS BONDING PIN NOTE: SnapNrack Mid Clamp SnapNrack Adjustable End Clamp SnapNrack UR-40 Rail Splice SnapNrack UR-60 Rail Splice q   SnapNrack module clamps contain a SnapNrack Channel Nut with integral bonding clips or pins in assembly to properly bond the system (except Universal End Clamps). Note: SnapNrack Ground Lug Assembly SNAPNRACK ULTRA SERIES RAIL 5/16"-18 X 1" BOLT S.S. WITH SPLIT LOCK WASHER S.S. SNAPNRACK GROUND LUG, 6-12 AWG SNAPNRACK BONDING CHANNEL NUT COPPER WIRE, TYP. SS BONDING CLIP (2 TOTAL) RAIL SPLICE ASSEMBLY SnapNrack Ultra Rail Splices contain integral bonding clips in assembly to properly bond the system. Note:  RAIL SPLICE ASSEMBLY SS BONDING PIN (2 TOTAL) snapnrack.com 52 Grounding Specications Ground Path Details Ilsco Lay-in Lug Assembly SNAPNRACK ULTRA SERIES RAIL #10 BOLT SS ILSCO GBL-4DBT GROUND LUG #10 NUT SS WITH STAR WASHER COPPER WIRE, TYP. GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMP U = UNIVERSAL END CLAMP TO EGC RACKING & RAIL CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSsnapnrack.com 53 Grounding Specications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMP U = UNIVERSAL END CLAMP ENPHASE MICRO- INVERTER GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMP U = UNIVERSAL END CLAMP SOLAREDGE OPTIMIZER TO EGC TO EGC Ground Path Details - Enphase Ground Path Details - SolarEdge snapnrack.com 54 INSTALLATION INSTRUCTIONS - SNAPNRACK GROUND LUG 1) Snap the SnapNrack Ground Lug into the rail channel on one rail per module row. 2) Place grounding conductor into slot underneath split ring washer. SnapNrack Ground Lug may be used in side or top channel, and may be rotated 90 degrees relative to slot to acilitate running copper across top o rails. Install Note: SnapNrack Ground Lug only Listed or use with 6-12 AWG solid copper conductor. Install Note: 3) Tighten hardware to 16 t-lbs. Grounding Specications INSTALLATION INSTRUCTIONS - ILSCO LAY-IN LUG 1) Drill and deburr a 1/4” hole in the back side o the rail or the Ilsco lug to attach to, place the bolt through the hole, and attach the lug assembly on one rail per module row. 2) Place grounding conductor into slot. Torque rail connection to 35 in-lbs. Install Note: Torque set screw to 20 in-lbs or #10- #14 solid and stranded copper, 25 in-lbs or #8 stranded copper, and 35 in-lbs or #4-#6 stranded copper. Install Note: 3) Tighten set screw per Ilsco’s recommendation (see below). • System has been evaluated to a maximum overcurrent device (OCD) protection level o 20 Amps. • Universal End Clamp (UEC) does not bond module to rail. Be sure to separately ground any modules that are only secured by UECs, especially during servicing. • SnapNrack recommends that bare copper never come into contact with aluminum. • SnapNrack Ground Lug: torque bolt to 16 t-lbs. The Ground Lug may be used in side or top channel. It may be rotated 90 degrees relative to slot to acilitate running copper across top o rails. • Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling o a hole in the rail. • Ilsco hardware connection to rail: 5 t-lbs. Torque or lug set screw: #10-#14 solid and stranded copper- 20 in-lbs, #8 stranded copper- 25 in-lbs, #4-#6 stranded copper- 35 in-lbs. Note: RACKING & RAIL CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSsnapnrack.com 55 Ground Path Details - DynoBond Grounding Specications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)M M M M M M M M E E TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP E = END CLAMP(+)(-)E E M M M M E E E E DYNORAXX DYNOBOND R/C (QIMS2), DynoRaxx (E357716) photovoltaic bonding jumper cat. no. DynoBond is an optional component that may be used with this system. The DynoBond jumper has been evaluated to provide module to module bonding. The DynoBond device attaches to the rame ange o adjacent modules. SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Subject: Report # 2017-03227.11 – Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System PZSE, Inc. – Structural Engineers has reviewed and analyzed the SnapNrack Ultra Rail Racking System, a proprietary mounting system constructed from modular parts, which is intended for rooftop installation of solar photovoltaic (PV) panels; and has provided the attached span tables. This review included the complete system including the “UR-40” aluminum rail (6005-T56 alloy), attachment devices, splice elements, and PV Panels. All information, data, and analysis contained within are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2015 International Building Code, by International Code Council, Inc. 3. 2015 International Residential Code, by International Code Council, Inc. 4. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5. Aluminum Design Manual 2015, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2015, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category II; Seismic Design Category = A - E Wind Loads: Basic Wind Speed (ultimate) per ASCE 7-10 = 110 mph to 190 mph. Includes roof pitches from 0° to 90°, up to 60 feet mean roof height, and exposure categories B, C, & D. Parapets, roof overhangs, and topographic wind speed adjustment have not been considered. See Appendix A for conversion to Service-level wind speeds per ASCE 7-05. Snow Loads: Ground Snow Load = 0 to 120 (psf). Spans are based on the sloped roof snow load (Ps) corresponding to each ground snow load. See Appendix B to adjust span tables for non-reducible snow loads. PV Modules: All solar PV modules with metal frames. “60-Cell” tables are applicable for modules up to 5’-6” (66”) long; “72-Cell” tables are applicable for modules up to 6’-6” (78”) long; and “Landscape” tables are applicable for modules up to 3’ 4-1/2” (40-1/2”) long in the narrow direction. Module length is defined to be perpendicular to the rail, regardless of panel orientation. If you have any questions, do not hesitate to call. Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA 1/366 October 17, 2019 RACKING & RAIL CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Subject: Engineering Certification for the State of Massachusetts Building Codes:1.ASCE/SEI 7-10, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2.2015 International Building Code, by International Code Council, Inc. 3.2015 International Residential Code, by International Code Council, Inc. 4.AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5.Aluminum Design Manual 2015, by The Aluminum Association, Inc. 6.ANSI/AWC NDS-2015, National Design Specification for Wood Construction, by the American Wood Council Design Criteria:Risk Category II Seismic Design Category = A - E Basic Wind Speed (ultimate) per ASCE 7-10: up to 190 mph Ground Snow Load = 0 to 120 (psf) This letter certifies that the loading criteria and design basis for the SnapNrack Ultra Rail Racking System with UR-60 Rail Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE,Inc.–StructuralEngineers Roseville, CA August 6, 2019 PZSE,Inc.–StructuralEngineershasprovidedengineeringandspantablesfortheSnapNrackUltraRailRackingSystemwithUR- 60 Rail, as presented in PZSE Report # 2018-11940.03, "Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar Photovoltaic Racking System". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Re:Report#2018-11940.03–SnapNrackUltraRailSolarPhotovoltaicRackingSystemwithUR-60Rail RACKING & RAIL CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 n1.00 4.20 .30 3.25 n1.00 1.00 SLOT 1.50 2.78 1.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM n.35 1.80 105°RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSSTANCHION - ROOF ATTACHMENT CUT SHEET R-109Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT The Enphase IQ Combiner 3™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 3 (X-IQ-AM1-240-3) To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • DurableNRTL-certiedNEMAtype 3R enclosure • Five-year warranty • UL listed To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. 2018-09-13 MODEL NUMBER IQCombiner3X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV productionmetering(ANSIC12.20+/-0.5)andoptional*consumptionmonitoring(+/-2.5). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) EnphaseMobileConnect™ CELLMODEM-03(4G/12-yeardataplan) CELLMODEM-01(3G/5-yeardataplan) CELLMODEM-M1(4GbasedLTE-M/5-yeardataplan) Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters.(AvailableintheUS,Canada,Mexico,PuertoRico,andtheUSVirginIslands, wherethereisadequatecellularserviceintheinstallationarea.) ConsumptionMonitoring*CT CT-200-SPLIT Splitcorecurrenttransformersenablewholehomeconsumptionmetering(+/-2.5). Circuit Breakers BRK-10A-2-240 BRK-15A-2-240 BRK-20A-2P-240 SupportsEatonBR210,BR215,BR220,BR230,BR240,BR250,andBR260circuitbreakers. Circuitbreaker,2pole,10A,EatonBR210 Circuitbreaker,2pole,15A,EatonBR215 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity 2 XA-PLUG-120-3 AccessoryreceptacleforPowerLineCarrierinIQCombiner3(requiredforEPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC,60Hz Eaton BR series busbar rating 125A Max.continuouscurrentrating(outputtogrid)65A Max.fuse/circuitrating(output)90 A Branchcircuits(solarand/orstorage)Uptofour2-poleEatonBRseriesDistributedGeneration(DG)breakersonly(notincluded) Max.continuouscurrentrating(inputfromPV)64 A Max.totalbranchcircuitbreakerrating(input)80Aofdistributedgeneration/90AwithIQEnvoybreakerincluded ProductionMeteringCT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WxHxD)49.5x37.5x16.8cm(19.5”x14.75”x6.63”).Heightis21.06(53.5cmwithmountingbrackets). Weight 7.5kg(16.5lbs) Ambient temperature range -40ºCto+46ºC(-40ºto115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor,NRTL-certied,NEMAtype3R,polycarbonateconstruction Wire sizes • 20Ato50Abreakerinputs:14to4AWGcopperconductors • 60Abreakerbranchinput:4to1/0AWGcopperconductors • Mainlugcombinedoutput:10to2/0AWGcopperconductors • Neutralandground:14to1/0copperconductors Alwaysfollowlocalcoderequirementsforconductorsizing. Altitude To2000meters(6,560feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional,802.3,Cat5E(orCat6)UTPEthernetcable(notincluded) Cellular Optional,CELLMODEM-01(3G)orCELLMODEM-03(4G)orCELLMODEM-M1(4GbasedLTE-M) (not included) COMPLIANCE Compliance, Combiner UL1741 CAN/CSAC22.2No.107.1 47CFR,Part15,ClassB,ICES003 Productionmetering:ANSIC12.20accuracyclass0.5(PVproduction) Compliance, IQ Envoy UL60601-1/CANCSA22.2No.61010-1 *ConsumptionmonitoringisrequiredforEnphaseStorageSystems. Enphase IQ Combiner 3 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC COMBINER CUT SHEET R-110Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general- duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ● Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ● UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATE NAME ADDRESSAPNEQUIP. CUT SHEETS ADDRESS kW PHOTOVOLTAIC PLANSAC DISCONNECT CUT SHEET R-111Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88447.260Corwin, Julie22 Mountain StFlorence, MA 0106205/11/2020SUBMIT FOR PERMIT