36-386 (2) 196 EMERSON WAY SM-2020-0041
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: 11790
Map: 36 p L
Block: 306
Lot: 001 '- SHEETMETAL PERMIT
_-
Permit: SHEETMETAL '
Category: SHEETMETAL
Permit# SM-2020-0041 PERMISSION IS HEREBY GRANTED TO:
Project# JS-2020-001523
Est.Cost: $15,950.00 Contractor. License: Expires:
Fee Charged:$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020
Balance Due:$.00 Owner: DARMON VERONICA&SHEINER DEBRA
#'of Fixtures:', Applicant: ROCK VALLEY HVAC
DigSafe# AT. 196 EMERSON WAY
UseGroup
ConstClass
ISSUED ON. 19-May-2020 AMENDED ON. EXPIRES ON:
TO PERFORM THE FOLLOWING WORK.-
HVAC
ORK.HVAC
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2020-003155 15-May-20 1319 $50.00
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck@northamptonma.gov
GeoTMSO 2020 Des Lauriers Municipal Solutions,Inc.
Comino ealth of Massachusetts
Sh al Permit
Date: 05/08/2020
'yqy vermit#,514 030
o�AT V
Estimated Job Cost: $15,95 4'' 10 ,`sip rmi ee: $ -0 I 3I
Plans Submitted: YES NO °ti'/4, P1 s Reviewed: YES NO
Business License#824 �O tis Applicant License# SM2626
Business Information: Property Owner/Job Location Information:
Name: Jesse Fortier(Rock Valley HVAC) Name: Rosemund Homes
Street: 296C Nonotuck Street Street: I It Emerson Way
City/Town: Florence City/Town:Northampton
Telephone: (413) 535-7804 Telephone: (413) 695-4195
Photo I.D. required/Copy of Photo I.D. attached: YES NO
Staff Initial
J-1 /M-1-unrestricted license
J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family ✓ Multi-family Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stories:l
Sheet metal work to be completed: New Work: ✓ Renovation:
HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
Provide American Standard ducted HVAC system with two zones. Furnace is 97%afue,two stage, with
variable speed ECM blower.
AC unit is 17-SEER two stage, system AHRI reference#201800941.
Fabricate and install custom sheet metal duct system. Ductwork to be sealed and insulated in accordance
with state and local code.
All ductwork to be run in conditioned space.
INSURANCE COVERAGE:
I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes ZNo ❑
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy 0 Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the
Massachusetts General Laws,and that my signature on this permit application waives this requirement.
Check One Only
Owner Agent ❑
Si ure of Owner or Owner's Agent
By checking this boxE,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will
be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation: YES NO
Progress Inspections
Date Comments
Final Inspection
Date Comments
Type of License:
By Master
Title ❑ Master-Restricted r �
Cityfrown ❑ Journeyperson
Signature of Licensee
Permit# ❑ Jou rneyperson-Restricted
License Number:
Fee$ ❑
Check at www.massgov/dpl
In ector Signature of Permit proval
Rock Valley Project Summary Date: April 23,2020
Entire House By:
' Rock Valley HVAC Inc.
296C NonotLrk Street,Florerxe,Ma 01062 Phone:(413)535-7804 Email:rockvalle^ac@yahoo.com Web:wwvrockvalleyhvac.com License:SM2626
Proiect Information
For: Rosemund Homes
Emerson Way,Northampton, Ma 01060
Phone: (413)695-4195
Email: rosemundllc@yahoo.com
Notes: Provide American Standard ducted HVAC system with two zones.Furnace is 97%afue,two
stage,with variable speed ECM blower.
AC unit is 17-SEER two stage,system AHRI reference#201800941.
Fabricate and install custom sheet metal duct system.Ductwork to be sealed and insulated in
Desiqn Information
Weather: Greenfield(Worcester Dd), MA, US
Winter Design Conditions Summer Design Conditions
Outside db -2 °F Outside db 85 °F
Inside db 72 °F Inside db 68 °F
Design TD 74 °F Design TD 17 'F
Daily range M
Relative humidity 50 %
Moisture difference 42 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 36357 Btuh Structure 20317 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfrn) 0 Btuh Central vent(0 cffn) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 36357 Btuh Use manufacturer's data n
Rate/swin multiplier 0.90
Infiltration Equipmenil sensible load 18285 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction qualityTight
Fireplaces 1 (Tight) Structure 500 Btuh
Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(fit) 3728 3728 Equipment latent load 500 Btuh
Volume(ft') 21450 21450
Air changes/hour 0.10 0.05 Equipment Total Load(Sen+Lat) 18786 Btuh
Equiv.AVF(cfm) 36 18 Req.total capacity at 0.70 SHR 2.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80AFUE Efficiency 0 SEER
Heating Input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 'F Total cooling 0 Btuh
Actual airflow 1434 cfm Actual airflow 1434 cfm
Air flow factor 0.039 cfm/Btuh Air flow factor 0.071 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.98
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
�► wry ht... 2020-May-080
Right-Suite®Unversal201919.0.19RSU24598 Page1
ACCA ...ftro\DesktoUobs\RosemundDarmon\Rosemund.rup Calc=MJ8 FrorgDoorfaces: E
N
Level 2
mow
Master Bed
KiVDin/Liv
MasterBath
WIC
Stairs Pan
Laundry
Bathroom Bedroom#2
Clos Closets
Foy
Garage
Bedroom#3
Job#: Rock Valley HVAC Inc. Scale: 1 :94
Performed for: Page 1
Rosemund Homes 296C Nonotuck Street RightSuite®Universal 2019
Emerson Way Florence,Ma 01062 19.0.19 RSU24598
Northampton,Ma 01060 Phone:(413)535-7804 semun Dar onRos s
Phone:(413)695-4195 obsU2osemund DartnonU�osemund.rup
w
rosemundllc@yahoo.com wwrockvalleyhvac.com rockvalleyhvac@yahoo.com
N
Jy ` ��1
Level 1
Now
ri
9
I
Finished
NIC
Job M Rock Valley HVAC Inc. Scale: 1 :94
Performed for: Page 2
Rosemund Homes 296C Nonotuck Street RightSLite®Universal 2019
EmersonWay Florence,W 01062 19.0.19 RSLJ24598
Northampton,Ma 01060 Phone: 413 535-78042020-May-08 09:55:09
Phone:(413)695-4195 obs\Rosemund Darmon\Rosemund.rup
rosemundllc@yahoo.com wvuwrodcvalleyhvac.com rockvalleyhvac@yahoo.com