Loading...
36-386 (2) 196 EMERSON WAY SM-2020-0041 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 11790 Map: 36 p L Block: 306 Lot: 001 '- SHEETMETAL PERMIT _- Permit: SHEETMETAL ' Category: SHEETMETAL Permit# SM-2020-0041 PERMISSION IS HEREBY GRANTED TO: Project# JS-2020-001523 Est.Cost: $15,950.00 Contractor. License: Expires: Fee Charged:$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020 Balance Due:$.00 Owner: DARMON VERONICA&SHEINER DEBRA #'of Fixtures:', Applicant: ROCK VALLEY HVAC DigSafe# AT. 196 EMERSON WAY UseGroup ConstClass ISSUED ON. 19-May-2020 AMENDED ON. EXPIRES ON: TO PERFORM THE FOLLOWING WORK.- HVAC ORK.HVAC THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2020-003155 15-May-20 1319 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck@northamptonma.gov GeoTMSO 2020 Des Lauriers Municipal Solutions,Inc. Comino ealth of Massachusetts Sh al Permit Date: 05/08/2020 'yqy vermit#,514 030 o�AT V Estimated Job Cost: $15,95 4'' 10 ,`sip rmi ee: $ -0 I 3I Plans Submitted: YES NO °ti'/4, P1 s Reviewed: YES NO Business License#824 �O tis Applicant License# SM2626 Business Information: Property Owner/Job Location Information: Name: Jesse Fortier(Rock Valley HVAC) Name: Rosemund Homes Street: 296C Nonotuck Street Street: I It Emerson Way City/Town: Florence City/Town:Northampton Telephone: (413) 535-7804 Telephone: (413) 695-4195 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family ✓ Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stories:l Sheet metal work to be completed: New Work: ✓ Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide American Standard ducted HVAC system with two zones. Furnace is 97%afue,two stage, with variable speed ECM blower. AC unit is 17-SEER two stage, system AHRI reference#201800941. Fabricate and install custom sheet metal duct system. Ductwork to be sealed and insulated in accordance with state and local code. All ductwork to be run in conditioned space. INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes ZNo ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy 0 Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner Agent ❑ Si ure of Owner or Owner's Agent By checking this boxE,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progress Inspections Date Comments Final Inspection Date Comments Type of License: By Master Title ❑ Master-Restricted r � Cityfrown ❑ Journeyperson Signature of Licensee Permit# ❑ Jou rneyperson-Restricted License Number: Fee$ ❑ Check at www.massgov/dpl In ector Signature of Permit proval Rock Valley Project Summary Date: April 23,2020 Entire House By: ' Rock Valley HVAC Inc. 296C NonotLrk Street,Florerxe,Ma 01062 Phone:(413)535-7804 Email:rockvalle^ac@yahoo.com Web:wwvrockvalleyhvac.com License:SM2626 Proiect Information For: Rosemund Homes Emerson Way,Northampton, Ma 01060 Phone: (413)695-4195 Email: rosemundllc@yahoo.com Notes: Provide American Standard ducted HVAC system with two zones.Furnace is 97%afue,two stage,with variable speed ECM blower. AC unit is 17-SEER two stage,system AHRI reference#201800941. Fabricate and install custom sheet metal duct system.Ductwork to be sealed and insulated in Desiqn Information Weather: Greenfield(Worcester Dd), MA, US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 'F Daily range M Relative humidity 50 % Moisture difference 42 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 36357 Btuh Structure 20317 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfrn) 0 Btuh Central vent(0 cffn) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36357 Btuh Use manufacturer's data n Rate/swin multiplier 0.90 Infiltration Equipmenil sensible load 18285 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction qualityTight Fireplaces 1 (Tight) Structure 500 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(fit) 3728 3728 Equipment latent load 500 Btuh Volume(ft') 21450 21450 Air changes/hour 0.10 0.05 Equipment Total Load(Sen+Lat) 18786 Btuh Equiv.AVF(cfm) 36 18 Req.total capacity at 0.70 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating Input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual airflow 1434 cfm Actual airflow 1434 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.071 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �► wry ht... 2020-May-080 Right-Suite®Unversal201919.0.19RSU24598 Page1 ACCA ...ftro\DesktoUobs\RosemundDarmon\Rosemund.rup Calc=MJ8 FrorgDoorfaces: E N Level 2 mow Master Bed KiVDin/Liv MasterBath WIC Stairs Pan Laundry Bathroom Bedroom#2 Clos Closets Foy Garage Bedroom#3 Job#: Rock Valley HVAC Inc. Scale: 1 :94 Performed for: Page 1 Rosemund Homes 296C Nonotuck Street RightSuite®Universal 2019 Emerson Way Florence,Ma 01062 19.0.19 RSU24598 Northampton,Ma 01060 Phone:(413)535-7804 semun Dar onRos s Phone:(413)695-4195 obsU2osemund DartnonU�osemund.rup w rosemundllc@yahoo.com wwrockvalleyhvac.com rockvalleyhvac@yahoo.com N Jy ` ��1 Level 1 Now ri 9 I Finished NIC Job M Rock Valley HVAC Inc. Scale: 1 :94 Performed for: Page 2 Rosemund Homes 296C Nonotuck Street RightSLite®Universal 2019 EmersonWay Florence,W 01062 19.0.19 RSLJ24598 Northampton,Ma 01060 Phone: 413 535-78042020-May-08 09:55:09 Phone:(413)695-4195 obs\Rosemund Darmon\Rosemund.rup rosemundllc@yahoo.com wvuwrodcvalleyhvac.com rockvalleyhvac@yahoo.com