Loading...
32C-067 (27) 2 CONZ ST - HEMPEST SM-2020-0042 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 10123 Map: 32C Block: 067 SHEETM ETAL PERMIT Lot: 001 ` Permit: 'SHEETMETAL Category: SHEETMETAL Permit## SM-2020-0042 PERMISSION IS HEREBY GRANTED TO: Project# JS-2020-001412 Est.Cost: $11,500.00 Contractor: License: Expires: 'Fee Charged:'$100.00 NOLAN PLUMBING&HEATING Sheetmetal-9758 08/28/2020 Balance Due:$.00 Owner: NORTHEMPTON ENTERPRISES INC #of Fixtures:: Applicant: NOLAN PLUMBING&HEATING i DigSafe :AT: 2 CONZ ST- HEMPEST UseGroup ConstC lass ISSUED ON: 21-May-2020 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: EXPANSION&RENO OF EXISTING SPACE THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2020-003198 20-May-20 600 $100.00 212 Main Street,Phone:(413);87-1240,Fax:(413)587-1272,Email:lhasbrouckid-norihamptonma.�;u� GeoTMS%2020 Des Lauriers Municipal Solutions,Inc. Commonwealth of Massachusetts City Of Northampton Date:, Sheet Metal Permit Permit# Estimated Job Cost: $ 1Permit Fee: $ 1V CD —T �lans'Sul�mitted: YES NO Plans Reviewed: YES NO Business icense# Applicant License # Business Information: Property Owner/Job Location Information: Name:NOI(A P(OM ti;V,�1Gcf ihC Name: W ct4 �h1evp%1�kS \t\C Street: ( C 1 c,v- i. !�A v Street: '2 CGI? Z S�rte 7 City/Town: GrTv&M mo, City/Town: Telephone: H 13 S 2Telephone: Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 4 -1-unrestricted license` J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office ," Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. /-over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: Renovation: HVAC Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: i 4 S-CAkkOA`,0n, p�y6w k, sok $Nk) SL V01 r1 ."i cctcc I ayj 2 fbr\ cnu44onc cr,-ri , �`�� s�allc,�l'r,vi dF S�D1� e(4, 'i 5,2(of f0 odea I uvms 2ucA ui 4o 6e -to tr At4 M q �oc� Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial INSURANCE COVERAGE: have a current liar insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes JNO❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: 1 A liability insurance policy d Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee dnac not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waive this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this boxLJ, I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progr"s luspertinnc Date Comments Final 1nSpoCt._.i_nn D:.I.I.e f llllll]L1115 Type of License: BY ❑ Master Title ❑ Master-Restricted City/Town ❑Journeyperson Signature of Licensee Permit# ❑J ou rneyperson-Restricted License Number' Fee$ ❑ Check at www mass goviripi Inspector Signature of Permit Approval MASSACHUSETTS DRIVER'S I NUMBER 0811412019 S65193527 EXP 0812612024 08126!1974 py t CtA55 RES? .END D NONE NONE Wii:�NKO ROBERT FRANCIS a 113 FRANKLIN ST GREENFIELD,MA 01301-2916 } A BLU SEX M DDD HGT 5'-10" �+ DD 08115!1079 Rer 07/71/2016 OVQ I2V// OMMONWEALTH OF MASSA HUS - • • • - • • BOARD OF SHEET METAL WORKERS I }y� ISSUES THE. FOLLOWING LICENSE I MASTER-UNRESTRICTED C a � d � I f ROBERT F MENKO y 113 FRANKLIN ST w. w GREENFIELD,MA 01301-2916 W U J 534615 9758 0812812020 } The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street, Suite 100 Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print LeLlibIN Name (Business/Organization/Individual):NOLAN PLUMBING & HVAC INC Address:26 CLARK STREET City/State/Zip:GREENFIELD MA 01301 Phone#:4138242204 Are you an employer?Check the appropriate box: Type of project(required): 1.[]I am a employer with 3 employees(full and/or part-time).* 7. ✓❑New construction 2.[]1 am a sole proprietor or partnership and have no employees working for me in 8. Remodeling any capacity.[No workers'comp.insurance required.] 9. ❑Demolition 3.1 1 am a homeowner doing all work myself.[No workers'comp.insurance required.]t 10 Building addition 4.[:]l am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.[:]Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions ❑I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.E:]Roof repairs fhese sub-contractors have employees and have workers'comp.insurance. 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.[:]Other 152,61(4),and we have no employees.[No workers'comp.insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. =Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:HARTFORD FIRE INSURANCE COMPANY Policy#or Self-ins.Lic.#:08 WEC AE5JE5 Expiration Date:31 DEC 2020 Job Site Address:2 CONZ STREET City/State/Zip:Northampton MA Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify er,under the pains and penalties of perjury that the information provided above is true and correct. Signature: Date: �l mkM Zdl U Phone#:413.824.2204 Official use only. Do not write in this vire a,to be completer/by cite or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: 7 C`t)Nf.4't 1IFNIPES-1 BP-202G-0818 GIs COMMONWEALTH OF 1 S,—;A - t S __ T Niap.13lock: 2C -06 71 C1TV OF NORT11 N11'' `t.)' I:ot:-001 Ptah`-SONS WITH UNRI•AiIS f RLDCO TRA TO Permit: _ Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGA. c.142i'- Cate r ,AI I ERATION RUI L D I N iJ P.i.:.r RM I.T Permit,', BP-2020-0818 Protect �r JS.,2020-001412 I=,st=,st. Cost S,1 0000.00 Feu: 52170.00 PERMISSION IS HEREBY GRANTED TO: (omst. C ki",� Corrtrtretor: License: Jse GK_up. BRIAN MCSWEENEY Ill 0697333 t,w Size(scl. ft.): 30666.24 ((1witer: NOR I'll f MF]QN 1,;N'l FRPRISFS INC Z,c�nit, ; t'tE tit > Applrcaut: BRIAN MCSWEENEY III -ter Applierrrrt Address: Phone: Insurrrrrc e: 4 FURNARI FARJNI 1 ANI F, .___ __ f>I i� �> -I488 ANDOVERMA01810 _ ISSUED 0,1V:3/13/2020 0:00:00 TO PERFORM THE FOLLOWING WORK:EXPANSION & RENO OF EXISTING SPACE POST TIIIS CARD SO IT tS VISIBLE FROM THE STRE L"T Inspector of Plumbing Inspector of Wiring DJI.w. Suitriina inspector Underground: Service: Meter: � Footings: - 2 Rough: Rough: House 4 Foundation: Driveway Final: Final: Final: Rough Frame: (,as: Fire DeCaartolen Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT NIAV BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy. Sinatnrt:: Fee h pe• hate Paid: Amount: Building 3/13/2020 0:0W00 S2I70.00 ,12 Niain Street,Phone W-1)587-12-10. Fa,v (41-33)?87-1272 Louis Fiashrouvk—Buildim-, ( ollintissir�ner rw weea ccx,IMNY SUBMITTAL DATA Order #: Date: 05/14/2020 Project: Hempest Dispensary Northampton Project #: Submitter: Jeff Baird F W WEBB COMPANY 145 Performance Boulevard, Springfield, Massachusetts 01104 413-781-1700 Information is subject to change without notice.Check local codes. Printed 05/14/2020 Date 05/14/2020 Project Name Hempest Dispensary Northampton Project Number FA%' `BB((W h`N) Client/Purchaser Submittal Summary Page Qty Tag# Model# Description 1 CU-1 YCD24B23S York Brand, 2 Ton, Air Conditioner, R-41 OA Refrigerant, 13 SEER/ 1-Stage, 208/230-1-60 1 GFU-1 TM9E040A10MP12 Mid Tier, 95%AFUE, Single Stage Gas Valve, X13 ECM Motor, 40 MBH, 14.5"Width Cabinet, 1000 CFM Nominal, Multi-Position, 115- 1-60 1 GFU-1 CF24AXAl 2 Ton, Full Case, Upflow/Downflow, Coil, 14.5" Cabinet Width, MaxAlloy Flex Coils, Aluminum Tube 1 GFU-1 S1-1TVMBH1 KITTXV,R-410A,3/4 INCH,CHATLEFF CO Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information &guidance. WARNING:Cancer and Reproductive Harm-www.P65Warnings.ca.gov Information is subject to change without notice.Check local codes. Printed 05/14/2020 YORKResidential Split Page:3 WSplit-System Outdoor Project Name: Hempest Dispensary Northampton Unit Model#: YCD24623S Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A1oMP12,CF24AXA1 Cooling PerformanceIII�IIII Total net capacity25.3 MBH � Sensible net capacity 19.1 MBH Seasonal Efficiency(at ARI) 13.50 SEER - "a• r Efficiency(at ARI) 11.50 EER Ambient DB temp. 95.0 °F -Zll Power input 2.27 kW v _ " Refrigerant �= i ZZ Refrigerant type R-41 OA Electrical Data Power supply 208/230-1-60 Unit min circuit ampacity 11.4 Amps Unit max over-current protection 15 Ams Dimensions&Weight Hgt 26.8 in. Len 24 in. Wth 24 in. Weight with factory installed options 115 lbs. Matchup Information ARI Reference Number 204327588 ARI Rated Capacity 25.3 MBH 2 Ton RI Rated Efficiency 13.5 SEER Note: Please refer to the tech guide for listed maximum static pressures Unit Features lllln ® • 13 SEER/1-Stage }.p ;I, n aur"r" �e saodtnq -' • Environmentally Friendly-CFC-free R-41 OA refrigerant delivers environmentally friendly performance with zero ozone depletion. • Durable Finish—The coated steel wire fan guard,coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep.Champagne colored powdercoat paint further protects external panels. • Fully Exposed Refrigerant Connections and a Single Panel Covering the Electrical Controls Make for Easy Servicing of the Unit • Rotary Compressor • Each Compressor is Protected Against Abnormal Pressures by an Internal Pressure Relief Valve and Factory Installed High Pressure Switch • Liquid Line Filter Drier • Quality Coils-Enhanced aluminum fins are mechanically bonded to copper tubing. • Secured Re-Usable Service Valves are Provided on Both the Liquid and Vapor Sweat Connections for Ease of Evacuating and Charging • Internally Protected Condenser Fan Motor Warranty • Five(5)Year Limited Parts Warranty • Ten(10)Year Limited Compressor Warranty • Extended Ten(10)Year Limited Parts Warranty when Product is Registered Online Within 90 Days of Purchase for Replacement or Closing for New Home Construction Information is subject to change without notice.Check local codes. Printed 05/14/2020 YtJRK® Residential Split Page:4 Split-System Outdoor Project Name: Hempest Dispensary Northampton Unit Model#: YCD241323S Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Factory installed Options YCD24B23S Equipment Options Option(s) Selected Product Category: Y York Brand Type: C Air Conditioner Nominal Series Efficiency&s Staging: D 13 SEER! 1-Stage Nominal Cooling Capacity: 24 2 Ton Refrigerant: B R-410A Refrigerant Voltage: 2 208/230-1-60 k. Product Generation: 3 Factory-Installed Options: S Field Installed Accessories O S1-1 HK0401 -Anchor Bracket Kit O S1-HPRKIT-6-Support Feet (1.0 lbs) (Snow Feet) Kit-6" (3.5 lbs) O S1-1HK0601 - Hurricane Kit(LX O S1-THXU280B-Wi-Fi Series) (1.4 lbs) Communicating Touchscreen O S1-2FD06700224- Blower-Off Thermostat with Proprietary Delay(2.0 lbs) Hexagon Interface (Black), with O S1-2LA04701024 -Advanced Low 2.8"display screen (1.0 lbs) Ambient Control Kit(1.8 lbs) O S1-THXU280W-Wi-Fi O S1-2LA06700424 -Standard Low Communicating Touchscreen Ambient Control Kit(0.8 lbs) Thermostat with Proprietary O S 1-2 PS06700524- Low Pressure Hexagon Interface (White), with Switch Kit(R-410A) (0.2 lbs) 2.8"display screen (1.0 lbs) O S1-2TD08700124BK-5 Minute O S1-THXU430W-Wi-Fi Time Delay(2.0 lbs) Communicating Touchscreen O S1-33102952310-Outdoor Thermostat with Proprietary Communicating Board Kit(2.0 lbs) Hexagon Interface (White), with O S1-51301535000-Touch-up 4.3"display screen (0.9 lbs) Paint: Champagne (1.1 lbs) O S1-51301537000-Touch-up Paint: Black(1.1 lbs) O S1-ACB-30 -Wall Mount Kit-30" (11.3 lbs) O S1-CCVREA26-Winter Cover Kit, 24"x 24"x 26" Height(6.2 lbs) O S1-CE-9722- High Ambient Condenser Fan Motor(1/12- 1/8 HP) (13.0 lbs) O S1-CHGTENT01 -Cold Weather Charging Tent(20.0 lbs) O S1-HPRKIT-12- Support Feet (Snow Feet) Kit- 12" (6.0 lbs) O S1-HPRKIT-3 -Support Feet (Snow Feet) Kit-3" (2.5 lbs) Information is subject to change without notice.Check local codes. Printed 05/14/2020 MYORK0 Residential Split Page:5 Split-System Outdoor Project Name: Hempest Dispensary Unit Model M YCD24B23S Northampton Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Typical Installation TYPICAL INSTALLATION 48'OVERHEAD LEARANCE NEC CLASS t WIRING NOTE: Ensure adequate wall support WEATHERPROOF —J DISCONNECT THERMOSTAT SWITCH NEC CLASS 2 WIRING 80"CLEARANCE Do not locate 3 BRACES outdoor unit closer Use for wall mount Meth than the indicated center brace under clearance to a dryer center of compressor. vent or to a 90+96 l TO FURNACE OR '1 AIR HANDLER furnace flue. TERMINAL BLOCK \ NEC CLASS 2 WIRING ' 10-CLEARANCE r AROUND PERIMETER (6"clearance permissible on one side only.see All outdoor wiring Alternative must be weatherproof. Installation Clearances.) NOTE CONTROL ACCESS SEAL OPENINGS 5 SNOW PUMP-UPS Ensure a minimum of PANEL Use permagum or equivalent. Use in deep snow areas 24"clearance between with fifth pump-up under any two units. MINIMUM 18'SERVICE ACCESS CLEARANCE center of compressor. Maintain minimum clearance on one side of access panel. A CAUTION Care must be taken to prevent ice frorn damaging the unit.Damage may occur from ice tailing onto unrt from a sloped roof or from a vertical drip fine due to a partial overhang. NO OVERHANG COVERING UNIT OVERHANG COMPLETELY COVERING UNIT OVERHANG PARTIALLY i COVERING UNIT 1 — 48'MINIMUM OVERHEAD CLEARANCE EARANCE INSTALLATION ACCEPTABLE INSTALLATION ACCEPTABLE INSTALLATION NOT RECOMMENDED (Refer to CAUTION above.) (Refer to CAUTION above.) NOTE: NOTE: The unit must be installed on a solid base above the grade. Install unit on flat surface.If installation surface is sloped,ensure The base must not be able to settle or shift causing strain on that unit slopes away from house structure at 114"per foot. refrigerant lines and possible leaks CAUTION: Special care must be taken to avoid recirculation of discharge air through condenser coil. Information is subject to change without notice.Check local codes. Printed 05/1412020 IS YO R K® Residential Split Page:6 Split-System Outdoor Project Name: Hempest Dispensary Unit Model#: YCD24B23S Northampton Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Unit Dimensions B DIMENSIONS Dimensions Refrigerant Connection Unit (Inches) Service Valve Size Model A I B C Liquid I Vapor YCD18B21(H,S) 23-1/21 24 24 YCD24B21(H,S) 26-3/4 24 24 314 YCD301321(H,S) 30 24 24 YCD36B21(H,S) 33-1/4 24 24 318 YCD42B21(H,S) 26-3/4 29-1/4 29-1/4 7/8 YCD48B21S 30 29-114 29-1/4 YCD60B21S 36-114129-1/4 29-114 7l8$ $Adapter fitting must be field installed for the required 1-1/8"fine set. All dimensions are in inches and are subject to change without notice. Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads. Information is subject to change without notice.Check local codes. Printed 05/14/2020 ww"YtJRK® Residential Split Page:8 Split-System Outdoor Project Name: Hempest Dispensary Unit Model#: YCD24B23S Northampton Quantity: 1 Tag#:CU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Typical Wiring TYPICAL FIELD WIRING ALL FIELD WIRING TO BE IN AC'C)RDANCF..WITH ELECTRIC CODE(NEC) AND/OR LOCAL CODES POWER WIRING — — — — POWER WIRING 24 VOLT CONTROL WIRING ————_ 208;730-1-60 —— CONTROL.WIRING �......_ /�_.� MINIMUM 18 GA.WIRE, (NEC CLASS 2) I FACTORY WIRING FURNACE OR AIR HANDLER TERMINAL BLACK trG W ! �•~ — �` I // I I I I •TIiRMINAL W 15 ONLY t -% •'�„_i i [ I I I REd)URED ON SYSTEMS CONTACTOR I I ( I I WITH HEAT. TERMINALS GND. �...,.,, i 1 1 I LUG COIL R\ \`1 � 1 G u CONDENSING UNIT ROOM THERMOSTAT I.................................................................................................................._.................................................................__.................................................._.._._....................— .__.._.........................................................; ALL OUTDOOR WIRING MUST BE WEATHERPROOF, USE COPPER CONDUCTORS ONLY. ALTERNATIVE INSTALLATION CLEARANCES MININ1UA1 CLEARANCE BETWLE'NLNI rs .... . ........................ 4AA. ......... .�.i I .J 1 NOTE: SI%RVK'Ti SERVICE SE•I[VICB Cls n ix-tw • twounits m hL i reduced to IS"minimum provided YM 1 ....... ...............Ir^:'....! the service accwss clearance is { increased to 24"minimuim and the IR- clearnce on each remuining side I , UNIT. liNrr• j is maintaincd at lA"minimtnn. ik" IA" IA' NOTL: (`karancemoixside ofthe mvr,i;;ati f t:1r+-�sct renalw-�Lt. unit may be reduced to ti"provided the deamtxro to each remaining sick - -�- 1 J!. is increased to 12"minimum,the 6 is 6 u7v iev acty"is im.reaw.d w 24" i f minimum,and the clearances between WALL any two unit,is nummained at 24" SBRVICI's L�---� minimum. 24' I ANDUNIT- SERVICE � T(t.IJNIT CAUTION: Special care must be taken to avoid recirculation of discharge air through condenser coil. Information is subject to change without notice.Check local codes. Printed 05/14/2020 or'YORK" Residential Split Page:9 Split-System Indoor Project Name: Hempest Dispensary Northampton Unit Model#: TM9E040A10MP12 Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Cooling Performance Total net capacity 25.3 MBH Sensible net capacity 19.1 MBH Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 62.0 °F Leaving WB temp. 59.0 °F Heating Performance Entering DB temp. 60 °F Heating output capacity(Max) 38 MBH ' Supply air 984 CFM Heating input capacity(Max) 40 MBH j Leaving DB temp. 95.8 °F Air temp.rise 35.8 °F AFUE 95.0 % Supply Air Blower Performance Supply air 984 CFM Ext.static pressure 0.6 IWG Blower speed description HIGH Unit Features Motor rating 0.50 HP • Unit Cabinet Constructed of Pre-Painted Steel Elevation 0 ft. . Sharp Edges Have Been Eliminated by Folding and Flattening the Sheet Drive type DIRECT Metal Indoor Electrical Data 60 • Full-Gasket,Rigid Independent Access Doors With View Ports and 1/4 Turn Power supply - - Knobs Unit max over-currentrentprotection 15 Amps Unit min circuit a y 10.40 Amps . Units are factory shipped for installation in upflow or horizontal applications Indoor Dimensions&Weight and may be converted for downflow applications. • Hi-tech Tubular Aluminized Steel Primary Heat Exchanger with Stainless Hgt 33 in. Len 29.5 in. Wth 14.5 in. Steel Tube/Aluminum Fin Secondary Heat Exchanger for Outstanding Weight with factory installed options 113 lbs. Matchu Information Efficiency. • Propane Convertible ARI Reference Number 204327588 Slide-Out Direct Drive Blower with High Efficiency Brushless DC Motor ARI Rated Capacity 25.3 MBH . Airflow Leakage Rate of Less Than 1%of Total Airflow @ 1"ESP Under RI Rated Efficiency 13.5 SEER Note: Please refer to the tech guide for listed maximum static pressures Duct Testing Conditions • Built-In,High-Level Self-Diagnostic Controls with Fault Codes for Reliable IIIII� / � AME® Operation Aw 4!' I ! f noA��N Warranty Five(5)Year Limited Parts Warranty A 20-year limited warranty on heat exchangers in residential applications. q=" A 10-year warranty on heat exchangers in commercial applications. • Extended lifetime heat exchanger and 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. Information is subject to change without notice.Check local codes. Printed 05/14/2020 YORK® Residential Split Page: 10 1 Split-System Indoor Project Name: Hempest Dispensary Northampton Unit Model#: TM9E040A10MP12 Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA7 Factory Installed_ Options TWEWA10MP12 Equipment Options Option(s) Selected RR Brand: T 3 Tier: M Mid Tier Efficiency: 9 95%AFUE Type: E Single Stage Gas Valve,X13 ECM Motor ' BTU Input: 040 40 MBH Cabinet Width: A 14.5'Width Cabinet Airflow: 10 1000 CFM Nominal Configuration: MP Multi-Position J- Voltage:1 115-1-60laffifflolliffim Product Generation: 2 Field Installed Accessories O S1-1BR0514-Bottom Return O S1-1NP0820- Propane (LP) Filter Rack Galvanized (Fits 14.5' Conversion Kit- includes stainless wide furnace) (8.0 lbs) steel LP Burners (3.0 lbs) O S1-1BR0614- Bottom Return O S1-1PS3307- High Altitude Kit Filter Rack(1"—4") Pre-Painted (0.2 lbs) To Match Furnace (Filters are O S1-1SR0200- Side Return Filter NOT included with the kit) (14.0 Rack 16x25x2 Contains 2" Hi- lbs) Velocity Pleated Filter(RNC or O S1-1CB0514- Combustible Floor AOR) (11.0 lbs) Base (For Downflow Applications) O S1-1SR0402- Side Return Filter (5.9 lbs) Rack 16x25x2 Contains 1" O S1-1CT0302-Concentric Vent Aluminum Mesh Filter(RNC or Termination Kit—2" (6.0 lbs) AOR) (4.5 lbs) O S1-1CT0302-636-Concentric O S1-2HU16700124- Humidistat Vent Termination Kit—2" (Canada) (5.0 lbs) (6.0 lbs) O S1-32924441000 - Natural (NAT) O S1-1CT0303-Concentric Vent Gas Stainless Steel Burner Kit Termination Kit-3"(9.0 lbs) (3.0 lbs) O S 1-1 CT0303-636-Concentric O S1-37327901001 -York Affinity Vent Termination Kit-3" (Canada) Cladding Kit(2.3 lbs) (9.0 lbs) O S1-1HT0901 -Sidewall Vent Termination Kit—3" (1.5 lbs) O S1-1HT0902-Sidewall Vent Termination Kit—2" (2.0 lbs) O S1-1NK0301 -Condensate Neutralizer Kit(3.0 lbs) O S1-1NP0347- Propane (LP) Conversion Kit(0.6 lbs) Information is subject to change without notice.Check local codes. Printed 05/14/2020 YtJRK® Residential Split Page: 11 or' Split-System Indoor Project Name: Hempest Dispensary Unit Model#: TM9E040A10MP12 Northampton Quantity: 1 Tag*GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Dimensions&Clearances LEFT SIDE FRONT RIGHT SIDE Combustion Air inlet Combustion Air Inlet _ ...._._.._. ...... ....... Condensate Drain' Gas Pipe (Downflow) Entry Gas PipeCondensate Drain Entry (Downflow) Vent Outlet—! Electrical Entry Electrical O Entry Vento tlet Condensate Drain ® (D 33 Condensate 1.bo 23- T r t ® (D Drain r t Thermostat Wiring Thermostat Wiring Optional Return Air Cutout(Either side) 14" i" 29p5" — N A 1.5" 4- I .56" �.. 43ent W -- Outlet B Combustion B Air Inlet 56 56" 20" — —►) �— 24.25" SUPPLY END RETURN END Cabinet&Duct Dimensions BTUH(kW) Nominal Cabinet Cabinet Dimensions(Inches) Approximate Operating Weights Input CFM{m31min} Size A B C Lbs TM9E040A10MP11 1000 A 14-112 13-3/8 11-3/4 113 TM9E060B12MP11 1200 B 17-1/2 16-3/8 13-1/4 122 TM9E080B12MP11 1200 B 17-1/2 16-3/8 14-3/4 126 TM9E080C16MP11 1600 C 21 19-7/8 16-1/2 136 TM9E100C16MP11 1600 C 21 19-7/8 18-1/4 142 TM9E100C20MP11 2000 C 21 19-7/8 18-1/4 145 TM9E120020MP11 2000 D 24-1/2 23-3/8 21-3/4 156 Ratings&Physical I Electrical Data Nominal Air Temp. Max.Outlet Max Min.wire Size BTUH(kW) Output AFUE Blower Blower Total Unit Input Airflow Rise Air Temp Size Over-Current Am (awg)@ 75 ft p MBH CFM % °F °F HP Amps Protect Amps one way TM9E040A10MP11 38 1000 95.0 45-75 180 1/2 6.8 11x8 15 9.5 14 TM9E060B12MP11 57 1200 95.0 40-70 180 1/2 6.8 11x8 15 9.5 14 TM9E080B12MP11 76 1200 95.0 50-80 170 1/2 6.8 11x8 15 9.5 14 TM9E080C16MP11 76 1600 95.0 40-70 165 1/2 6.8 1100 15 9.5 14 TM9E100C16MP11 95 1600 95.0 45-75 170 1/2 6.8 1100 15 9.5 14 TM9E100C20MP11 95 2000 95.0 50-80 165 3/4 8.4 1101 15 10.9 14 TM9E120D20MP11 114 2000 95.0 50-80 175 3/4 8.4 11x11 15 10.9 14 NOTES: Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-70-latest edition)and all local codes. The furnace shall be installed so that the electrical components are protected from water. Information is subject to change without notice.Check local codes. Printed 05/14/2020 YORK® Residential Split Page: 12 Split-System Coil Project Name: Hempest Dispensary Northampton Unit Model#: CF24AXAl Quantity: 1 Tag*GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Cooling Performance Total gross capacity 25.3 MBH Sensible gross capacity 19.1 MBH Ambient DB temp. 95.0 °F Refrigerant Refrigerant type R-41 OA Coil Dimensions&Weight Hgt 19.5 in. Len 21.5 in. Wth 14.5 in. Weight with factory installed options 40 lbs. Matchup Information ARI Reference Number 204327588 ARI Rated Capacity 25.3 MBH ARI Rated Efficiency 13.5 SEER Wetering Device S1-1TVMBH1 (or equiv Note: Please refer to the tech guide for listed maximum static pressures & I�Irllll II III IIII�I��I AMAM®V i I I GUAl1TY �P� (\Ge�Od"Hd�6'0'keepktg �� Unit Features • CF Series is Upflow/Downflow Only Application.If Removed from Case,will Need Diverter Available on Accessory Page • Copper Sweat Connect Fittings • Aluminum Tube/Aluminum Fin Coil • Rigid Case Construction Interior Endoskeleton for Structural Support,Flush Side,and Locks in Insulation • G30 Galvanized Steel Case • Long Life Aluminum Coils • Quality Aluminum or G90 Galvanized Steel Construction • Foil Faced Improved Insulation Design • Bolt-on-TXV Provides Easy Installation;Some Models Are Available with Factory Installed TXV • 20.5'Casing for Easy Attic Access • Thermal Plastic Drain Pan Warranty • Five(5)Year Limited Parts Warranty • Ten(10)Years Extended Limited Parts Warranty(with Registration) Information is subject to change without notice.Check local codes. Printed 05/14/2020 � ® Residential Split Page: 13 YO RK Split-System Coil Project Name: Hempest Dispensary Northampton Unit Model#: CF24AXAl Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 Factory Installed Options CF24AXA1 Equipment Options Option(s) Selected 4 Product Type: C Coil Product Category: F Full Case, Upflow/Downflow Capacity: 24 2 Ton Cabinet Width: A 14.5'Cabinet Width Refrigerant/TXV: X MaxAlloy Flex Coils Coil Options: A Aluminum Tube Product Generation: Field Installed Accessories • S1-1TVMBH1 - KIT,TXV,R- 410A,3/4 INCH,CHATLEFF CO (1.2 lbs) Information is subject to change without notice.Check local codes. Printed 05/1412020 a, Residential Split Page: 14 YORK Split-System Coil Project Name: Hempest Dispensary Unit Model M CF24AXAl Northampton Quantity: 1 Tag#:GFU-1 System: YCD24B23S,TM9E040A10MP12,CF24AXA1 CF Coil Dimensions DIMENSIONS CF Dimensions 2 Refrigerant Connections 3.4.5 19-ve - - Models' (OWNING) `�-`-C(OPENING) Height Width Opening Widths Line Size A 8 C D Liquid Vapor CF18A'A 1 19-112 14-112 13-1/2 13-1/2 CF18BXAl 19 17-1/2 16-1/2 16-1/2 CF24A'A1 19-1/2 14-1/2 13-1/2 13-1/2 I. CF24BXA1 19 17-1/2 1 16-1/2 16-1/2 A CF24CXAl 21 21 20 20 CF30AXA 1 21-5/8 14-1/2 13-1/2 13-1/2 CF30B'A1 23 17-1/2 16-112 16-1/2 3/4 CF30CXAl 21 21 20 20 CF30OXAl 25 24/112 23-112 23-1/2 C F36AXA 1 25-1/2 14-1/2 13-1/2 13-1/2 CF36B'A1 25-5/8 17-1/2 16-1/2 16-1/2 3/8 20 V2° B ( , � CF36CXA1 23 21 20 20 21-112" CF36DXA1 25 24-1/2 23-1/2 23-1/2 CF426XAl 25 17-1/2 16-1/2 16-112 CF42C'A1 25 21 20 20 CF42DXAl 25 24-1/2 23-1/2 23-1/2 BOTTOM OPENING CF48C"A1 27 21 20 20 DIMENSIONS 7/8 14.118„ CF48DXA1 27 24-1/2 23-1/2 23-1/2 D(OPENING; / CF60C"A1 33 21 20 20 ��'!s1 `4` CF60DXAl 32-3/4 24-1/2 23-1/2 23-1/2 CF64DXA1 32-3/4 24-1/2 23-1/2 23-1/2 1.Asterisk(')denotes coil model is available as a flex coil or with factory installed TXV. 2. All dimensions are in inches. 3. Refrigerant line sizes may require larger lines for extended line lengths.See Application Data part number 247077. 4.Adapter fitting must be field installed for other line set size. 5. See outdoor unit technical guide for proper line set size. DIMENSIONS CM `-� , � c Connections3,4 Dimensions ,5ts1/8„ 2 Refrigerant G ' , (OPENIPENING) Models Height Width Opening Widths Line Size A B C D Liquid Vapor CM18A'A1 19-1/2 14-1/2 13-1/2 13-1/2 CM18BXAl 19 17-1/2 16-1/2 16-1/2 CM24A'A 1 19-112 14-1/2 13-1 J2 13-112 A CM 24B'A 1 19 17-1/2 16-1/2 16-1/2 CM24CXAl 21 21 20 20 CM 30A'A 1 25-1/2 14-1/2 13-1/2 1 13-112 CM30B"A1 23 17-1/2 16-1/2 16-112 314 CM30CXA1 23 21 20 20 L CM30DXA1 25 24/112 23-1/2 23-112 CM36AXA l 25-1/2 14-1/2 13-112 13-1/2 CM36B'A1 25-5/8 17-1/2 16-1/2 16-1/2 3!8 21-112„ CM36C'A1 25 21 20 20 CM36DXAl 25 24-112 23-1/2 23-1/2 CM42C'A1 27 21 20 20 CM42DXAl 27 24-1/2 23-112 23-1/2 BOTTOM OPENING CM48C"A1 33 21 20 1 20 DIMENSIONS CM480'A1 32-3/4 24-1/2 23-1/2 23-112 7/8 19'1'9' CM60C"A1 33 21 20 20 D(OPENING) CM60D-A1 32-3/4 24-1/2 1 23-112 23-1/2 Ap9Y:1-991 CM64DXAl 32-3/4 24-112 1 23-112 23-112 1. Asterisk(')denotes coil model is available as a flex coil or with factory installed TXV. 2. All dimensions are in inches. 3. Refrigerant line sizes may require larger lines for extended line lengths.See Application Data part number 247077. 4.Adapter fitting must be field installed for other line set size. 5. See outdoor unit technical guide for proper line set size. Johnson Controls Unitary Products 3 Information is subject to change without notice.Check local codes. Printed 05/14/2020 ............... F- BATH IF F20-5 10x10 4WA ---- BREAK �'OUNTING RM p ROOM VAULT F2 0 E -6 6 f-2-04 F207 4 Y 8X8 RE5. 8X8 4WAYrF�nFE 18X8 , 4WAY 6" 6'' 101, 12" Pi I rl 12" ----------- 14'' ---------- OFFICE - --------- F -3] ---------- 203 6X R ........... 6X6PACKAGING 8X8 RE51� F-2-0-2-] 4WAY 23 wrightsoft Load Short Form Jo Date: May 1342020 Entire House By: Jeff B NOLAN PLUMBING AND HEATING Project Information For: HEMPEST DISPENSARY 20 CONZ ST, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db(°F) -5 97 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 65 22 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/Ib) 49 42 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftZ) (Btuh) (Btuh) (cfm) (cfm) SECOND FL. SYSTEM 960 18615 18057 889 889 FIRST FL. SYSTEM 1231 22211 21930 1085 1085 Entire House 2191 40826 39744 1974 1974 Other equip loads 0 0 Equip. @ 1.02 RSM 40539 Latent cooling 10681 TOTALS I 2191 I 40826 I 51220 I 1974 I 1974 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 08:19:49 wrightSOft" Right-Suite(g)Universal 2017 17.0.28 RSU18116 Page 1 PR.i ...cumenls\Wrightsoft HVAC\HEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N Load Short Form Job: RT-678423 Wry tso , Date: May 13,2020 FIRST FL. SYSTEM By: Jeff B NOLAN PLUMBING AND HEATING Project • - For: HEMPEST DISPENSARY 20 CONZ ST, NORTHAMPTON, MA Design Information Htg Clg Infiltration Outside db(°F) -5 97 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 65 22 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/Ib) 49 42 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1085 cfm Actual air flow 1085 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) SALES FLOOR 883 12680 14803 619 732 ENTRY 233 6431 2408 314 119 SECURITY 115 3100 4719 151 233 FIRST FL. SYSTEM 1231 22211 21930 1085 1085 Other equip loads 0 0 Equip. @ 1.02 RSM 22369 Latent cooling 5644 TOTALS I 1231 I 22211 I 28013 I 1085 I 1085 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 08:19:49 %_ wrightsbft" Right-Suite®Universal 2017 17.0.28 RSU18116 Page ,'M ...currents\Wrightsoft HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N Job: RT-678423 . wrightsoft Load Short Form Date: May 13,2020 SECOND FL. SYSTEM By: Jeff B NOLAN PLUMBING AND HEATING Project I • • For: HEMPEST DISPENSARY 20 CONZ ST, NORTHAMPTON, MA Design Information Htg Cig Infiltration Outside db (°F) -5 97 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 65 22 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference(gr/Ib) 49 42 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 889 cfm Actual air flow 889 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.78 ROOM NAME Area Htg load Clg load Htg AVF Cig AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) VAULT 104 1655 479 79 24 BREAK RM 174 2682 5583 128 235 CORRIDOR 128 230 184 11 9 BATH 60 5122 1760 245 87 COUNTING RM 77 746 1201 36 59 OFFICE 144 2919 3653 139 180 PACKAGING 154 2685 3447 128 170 STAIRS-CLST 120 2576 1749 123 86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 08:19:49 ►. wrightSOft Right-Suite®Universal 2017 17.0.28 RSU18116 Page / + ...currents\Wrightsoft HVAC\HEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N SECOND FL. SYSTEM 960 18615 18057 889 889 Other equip loads 0 0 Equip. @ 1.02 RSM 18418 Latent cooling 5037 TOTALS I 960 I 18615 I 23455 I 889 I 889 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-13 08:19:49 ►: wrtghtsoft Right-Suite®Universal 2017 17.0.28 RSU1 8116 Page ...cuments\Wrighlsoft HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N Building Analysis Job: RT-678423 - I- wrightsoft` gnaDate: May 13,2020 Entire House By: Jeff B NOLAN PLUMBING AND HEATING Project Information For: HEMPEST DISPENSARY 20 CONZ ST, NORTHAMPTON, MA Desiqn Conditions Location: Indoor: Heating Cooling Chicopee Falls/West, MA, US Indoor temperature (°F) 70 75 Elevation: 246 ft Design TD (°F) 65 22 Latitude: 42°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 49.5 41.7 Dry bulb(°F) -5 97 Infiltration: Dailyrange (°F) - 23 ( M ) Method Simplified V\kt bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btu h/111 Btuh %of load Walls 5.6 10302 25.2 Veniiabw Glazing 37.0 5042 12.4 veils Dx1s Doors 25.3 1063 2.6 Ceilings 3.5 4863 11.9 kfbatkn Floors 6.3 7702 18.9 Infiltration 2.9 5788 14.2 Ducts 2527 6.2 0ming Piping 0 0 Floors Humidification 0 0 lirx}s Ventilation 3538 8.7 Adjustments 0 Total 1 40826 100.0 Component Btuh/ft2 Btuh %of load Walls 1.5 2786 7.0 Glazing 50.1 6826 17.2 V�dlstilaial Doors 12.5 525 1.3 Gating Ceilings 3.0 4163 10.5 Floors 0 0 0 Infiltration 0.5 1051 2.6 aha' Ducts 1064 2.7 Ventilation 1199 3.0 CerifliI71trraig Irterr>d C�irsInternal gains 22130 55.7Blower 0 0 Adjustments 0 Iso Total 39744 100.0 Latent Cooling Load= 10681 Btuh Overall U-value=0.096 Btuh/ftz-°F Data entries checked. 2020-May-13 08:19:49 wrightsoft' Right-Suite®Universal 2017 17.0.28 RSU18116 Page 1 �^ ...cuments\wrightsoft HVAC\HEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N Building Analysis Job: RT-678423 wriglhtsoft` gnay Date: May 13,2020 FIRST FL. SYSTEM By: Jeff B NOLAN PLUMBING AND HEATING Project For: HEMPEST DISPENSARY 20 CONZ ST, NORTHAMPTON, MA Design Conditions Location: Indoor: Heating Cooling Chicopee Falls/West, MA, US Indoor temperature (°F) 70 75 Elevation: 246 ft Design TD(°F) 65 22 Latitude: 42°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 49.5 41.7 Dry bulb(°F) 5 97 Infiltration: Dailyrange (°F) - 23 ( M ) Method Simplified Wet bulb('F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft' Btuh %of load Walls 5.6 4966 22.4 QJds Glazing 37.0 1043 4.7 NiIs Infiltration Doors 25.3 1063 4.8 Ceilings 7.8 3243 14.6 Floors 6.3 7702 34.7 Cawing Infiltration 2.9 2746 12.4 Ducts 1447 6.5 Doors Piping 0 0 Floors Humidification 0 0 Ceilings Ventilation 0 0 Adjustments 0 Total 22211 100.0 -Component Btuh/fF Btuh % of load Walls 1.5 1343 6.1 VNIIs Glazing 73.5 2072 9.5 Gaarg Doors 12.5 525 2.4 Dtxrs Ceilings 6.6 2776 12.7 Floors 0 0 0 Infiltration 0.5 499 2.3 Calings Ducts 615 2.8 Ventilation 0 0 Irfiltrdirns IrteTal Cies Internal gains 14100 64.3 Dui Blower 0 0 Adjustments 0 Total 1 219301 100.0 Latent Cooling Load=5644 Btuh Overall U-value=0.106 Btuh/ft2-°F WARNING:window to floor area ratio=2.3%-less than 5%. 2020-May-13 08:19:49 '+ W1 ightsoft Right-Suite@ Universal 2017 17.0.28 RSU18116 Page 2 ...cuments\Wrightsoft HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N Buildin Anal sis Job: RT-678423 wrl htsoft y Date: May 13,2020 SECOND FL. SYSTEM By: Jeff B NOLAN PLUMBING AND HEATING Project Information For: HEMPEST DISPENSARY 20 CONZ ST, NORTHAMPTON, MA Design Conditions Location: Indoor: Heating Cooling Chicopee Falls/West, MA, US Indoor temperature (°F) 70 75 Elevation: 246 ft Design TD (°F) 65 22 Latitude: 42°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 49.5 41.7 Dry bulb(°F) 5 97 Infiltration: Dailyrange(°F) - 23 ( M ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftz Btuh %of load Walls 5.6 5335 28.7 Glazing 37.0 3999 21.5 Verlblebw Doors 0 0 0 WAIS Ceilings 1.7 1620 8.7 [qcls Floors 0 0 0 Infiltration 2.9 3043 16.3 Ducts 1080 5.8 ��� Piping 0 0 Humidification 0 0 Gazing Ceilings Ventilation 3538 19.0 Adjustments 0 Total 18615 100.0 —Component Btu h/112 Btuh %of load Walls 1.5 1443 8.0 Glazing 46.2 4990 27.6 V\13IIs Me tilation Doors 0 0 0 Ceilings 1.4 1387 7.7 Floors 0 0 0 Gating Infiltration 0.5 553 3.1 Ducts 456 2.5 Ventilation 1199 6.6 InterrEll Gars Internal gains 8030 44.5 Blower 0 0 li Adjustments 0 9r Total 1 1 18057 100.0 fl Ducts Latent Cooling Load =5037 Btuh Overall U-value=0.083 Btuh/ft2-°F Data entries checked. , � �,� ,. 2020-May-13 08:19:49 Right-SuileOUniversal 2017 17.0.28 RSU18116 Page + ...cuments\Wrighlsofl HVAMHEMPEST-NORTHAMPTON.rup Calc=MJ8 Front Door faces: N N Level 1 HALL NOT IN SCOP SALES FLOO 23'-6' SECURIT` ENTR) 14-7'4-111� Job#: RT-678423 NOLAN PLUMBING AND HEATING Scale: 1 : 88 Performed by Jeff B for: Page 1 HEMPEST DISPENSARY Right-Su ite®Universal 201 7 20 CONZ ST NORTHAMPTON,MA 17.0.28 811 2020-May--11 3 3 08:20:30 30 ...oft HVAMHEMPEST-NORTHAMPTON. N SECOND FLOOR BATH BREAK RA VAULT COUNTING RI CORRIDOF OFFIC' STAIRS-CLS PACKAGING Job#: RT-678423 NOLAN PLUMBING AND HEATING Scale: 1 : 88 Performed by Jeff B for: Page 2 HEMPEST DISPENSARY Right-Suite®Universal 2017 20 CONZ ST NORTHAMPTON,MA 17.0.28 811 2020-May--113 3 08:20:30 30 ...oft HVAC\HEMPEST-NORTHAMPTON.