25C-053 (13) 51 LINCOLN AVE BP-2020-1066
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block:25C-053 CITY OF NORTHAMPTON
Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: shed BUILDING PERMIT
Permit# BP-2020-1066
Project# JS-2020-001810
Est.Cost:
Fee: $50.00 PERMISSION IS HEREBY GRANTED TO:
Const.Class: Contractor: License:
Use Group: Homeowner as Contractor
Lot Size(sa. ft.): 10062.36 Owner. MEERBERGEN CHADD
Zoning URB(100)/ Applicant. MEERBERGEN CHADD
AT. 51 LINCOLN AVE
Applicant Address: Phone: Insurance:
51 LINCOLN AVE (508) 221-4609 O
NORTHAMPTONMA01060 ISSUED ON:4/22/2020 0:00:00
TO PERFORM THE FOLLOWING WORK:199 SQ FT SHED
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy si}"nature:
FeeType: Date Paid: Amount:
Building 4/22/2020 0:00:00 $50.00
212 Main Street,Phone(413)587-1240,Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
File#BP-2020-1066
APPLICANT/CONTACT PERSON MEERBERGEN CHADD
ADDRESS/PHONE 51 LINCOLN AVE NORTHAMPTON (508)221-4609()
PROPERTY LOCATION 51 LINCOLN AVE
MAP 25C PARCEL 053 001 ZONE URB(100)/
THIS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out
Fee Paid.
Typeof Construction: 199 SO FT SHED
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/Statement or License
3 sets of Plans/Plot Plan
THE/FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INF RMATION PRESENTED:
Approved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND/OR Special Permit With Site Plan
Major Project: Site Plan AND/OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received&Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission Permit DPW Storm Water Management
Demolition Delay
t� Ld za
Signature of Building Official Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of
Planning&Development for more information.
City of Northampton
•�'' ' '' Massachusetts
DEPARTMENT OF BUILDING INSPECTIONS
212 Main Street a Municipal Building �41�
�\J, Northampton, MA 01060 fs{7r 317��0
4YOR
4 ` 0
I"No
ACCES', R CTURE PERMIT APPLICATION
0;�,�O
(For freestanding structur ; 4 as t an 200 sq. ft., at least 5 feet from any other structure)
-,/ Check# 17/77
� C)
PLEASE TYPE OR PRINT ALL INFORMATION
1. Name of Applicant: E#,*,o 4,vAl {
Address: S/ G/AJ691- ) I'/E. Telephone: UF 22� -`f��9kwv Z.? Aio
2. Owner of Property: Si9�►^G ,A�3V�'
Address: 9T z Telephone:
3. Status of Applicant:_Ow
ner_Contractor /
4. Structure Location: UAtm e 1,,,2e- 1 a-'I�
Parcel ID: Zoning Map 0-25f- Parcel # 0.53 District(s)
(TO BE FILLED IN BY THE BUILDING DEPARTMENT)
S. Use of Propert�--Single or Two Family:—IV/Multifamily: Commercial:
6. Description of Proposed Structure:
One Story Shed under 200 sq.ft.: v Freestanding Deck under 200 sq.ft., less than 30"above grade:
SIZE OF STRUCTURE: cel
Other(describe):�/
7. Attached Plans: Sketch Plan /Site Plan Plot Plan
8. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW YES
IF YES: Has a permit been, or need to be, obtained from the Conservation Commission?
Needs to be obtained Obtained , Date issued
CONTINUED ON NEXT PAGE
9. ALL INFORMATION MUST BE COMPLETED; PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION.
This column to be filled in by
the Building Department
Existing Proposed Required by Zoning
Lot size
Frontage N/A N/A N/A
Front:
Setbacks: Side:
Rear:
Height .�
% Open space:
(Lot area minus bldg and
paved parkin )
10.Certification: I hereby certify that the information contained herein is true and accurate to
the best of my knowledge.
DATE: J� �5 ��� APPLICANT'S SIGNATURE _
NOTE: Issuance of a permit does not relieve an appli �Vurde��to with all zoning requirements
and obtain all required permits from the Conservation Commission, Department of Public Works and other
applicable permit granting authorities
P,q � 0.Cc ka--. herr CaK �
J
.� Zc�zo 1�tO glo S�
PROVIDE ROOF VENT
LSTA 24 RIDGE STRAPS E.O.R.
(3)-1X12 RIDGE
1/2"PLYWOOD ROOF SHEATHING
12
2 X 8 RAFTERS @ 16"o.c.
12
2 X 6 T&G FLOOR
PROJECTING SOFFIT
u
1 X 8 CEILING JOISTS @ 16"o.c.
LAP TO STUDS AND SET ON LEDGER
1 X 6 LEDGER-4"TIMBERLOC
0o Q CONNECTION
in
4-i
_ F y 2 X 4 STUD WALL @ 16"o.c.
ze
0 (BALLOONFRAME)
00
�o 1/2"PLYWOOD WALL SHEATHING
Co
SIMPSON DTT2ZANCHORS @ EACH PIER
3/4 ADVANT CH T G (2)-1 X 10 P.T.BEAM
<< : 1 X 8 P.T.JOISTS @ 12"o.c.
•, 10"SONO-TUBE PIER w/24"BIGFOOT
OR DIAMOND PIER 75/63
,lv •f
.7
.tet 1:
SCALE: 1/4" = P-0"
there designs are the property of
brook m-t-bergen designs and may
not be reproduced electronically
SCALE: 118 rr— [7 I_O n or in any other manner without the espress
consent of brook meerbergen.
MM
IE
4
�o
® 2
D
® 3 W4=W0j
EAST ELEVATION I NORTH ELEVATION
facing ezeter street J
0.0n
20'-0" O
3 L
o S
n
0o u
C
PLAN
--- — - — = storage loft above
4
2
WEST ELEVATION SOUTH ELEVATION
facing jairjield street
0
F-91 11 3
I II I I II I 741-611 2'-6"
I II II II II II II II II III
II II II II II II II II II III
O
II II II II I II II II II III '
II II II II II II it II II III C4
II II II II II II II I II III
6-61/2"
PLAN
9'-9" 9'-9"
w
b
3 PIERS
a
0
0
20'-0"overall length(beam face)
SCALE: 1/4" = 1'-0"