Loading...
39A-076 (2) 492 PLEASANT ST SM-2020-0034 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: .11916 Map: — --39A -- b Block: !076 SHEETM ETAL PERMIT Lot: ;001 Permit: SHEETMETAL Category: jSHEETMETAL Permit# SM-2020-0034 PERMISSION IS HEREBY GRANTED TO: Project# JS-2020-001167 Est.Cost: $58,880.00 Contractor: License: Expires: Fee Charged:l$50.00 AARON MORIN Sheetmetal-533 10/28/2021 Balance Due:S.00 Owner: SUHER ERIC #of Fixtures: Applicant: AARON MORIN DigSafe# j AT: 492 PLEASANT ST UseGroup ConstClass �1. ISSUED ON: 13-Mar-2020 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK.- INSTALL MINISPLITS THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Shcetmetal REC-2020-002882 13-Mar-20 4114 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbroucknnorthamptonma.gov GeoTMS®2020 Des Lauriers Municipal Solutions,Inc. Commonwealth of Massachusetts Sheet . Date: ( � ^� P rmi #_ S� ' 3 y Estimated Job Cost: $ r� f1 7 MAR 1 3 2020 Pe t ee: $ ,,T1 � Plans Submitted: YES NO �'�.,T�,;�";,'^� ew d: YES NO 4 ON•�,14Otor Business License# -3 Applicant License— Business I ec es - Business Information: Property Owner/Job Location Information: Name: ( C`7Y� ``(GYt✓\ ( "RA(kt Name: Street: 1400 l�?. � t Street: City/Town: WQSA t�G` 1 � City/Town: � Telephone: 1�J ''L4 L-- Telephone: Photo I.D. required/Copy of Photo I.D. attached: YES l/ NO �-� Staff Initial - M-1-un:res�tricteVe) J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft./2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. 6,1 A�over 10,000 sq. ft. Number of Stories: Sheet metal work to be completed: New Work: Renovation: f/ HVAC (/ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: 19— rVork 5 9e 4arA.L C e, d l90 000 o,cry ,B6Ak_5CLAct C INSURANCE COVERAGE: I have a current liabili insurance policy or' s equivalent which meets the requirements of M.G.L. Ch. 112 Yes No❑ If you have checked Yes, indicate the pe of coverage by checking the appropriate box below: A liability insurance policy Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this boxEl,I hereby certify that all of the details and information 1 have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Pro%!ress Inspections Date Comments Final Inspection Date Comments Type of Lic e: By aster / Title ElMaster-Restricted L X City/Town ❑Journeyperson Signature of Licensee Permit# '-'> ❑Joumeyperson-Restricted License Number: Fee$ ❑ Check at www.mass.gov/dpl ."bat,I 14 U In pector Signature of Permit Approval g COMMONWEALTH OF MASSACHUSETT . .. • • " • • _ JNJASSA 'F1€.?SETTS DRIVER'S BUAKU OF LICENSE SHEET METALWORKERS ;y ISSUES THE FOLLOWING LICENSE <k �lFr ,HC4 Ba END 10 NUMBER Lu MASTER-UNRESTRICTED cc g� NONE S19852961 Ob y, '. DOB AARON S MORIN z10-14.1971 140 WEST ST W o SEX M NST 5.11 WEST HATFIELD, MA 01088-9500 z ms z°A91R S t�" e 140 WEST ST W HATFIELD,MA 01088.9500 533 10/28/2021 719370 0010.152015 Rev O7-1SZ009 The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 11 Lafayette City Center 2 Avenue de Lafayette, Boston,MA 02111-1750 www massgov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Leeibly Name (Business/Organization/Individual): Aaron Morin Sheet Metal Address: 140 West Street City/State/Zip: West Hatfield, MA. 01088 Phone#: 413-427-1416 Are you an employer?Check the appropriate box: Type of project(required): 1.H I am a employer with 5 4. ❑ I am a general contractor and 1 6. ❑New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. modeling ship and have no employees These sub-contractors have g. [J Demolition working for me in any capacity. employees and have workers' y C]Building addition [No workers' comp.insurance comp.insurance. . re uired5. E] We are a corporation and its 10.El Electrical repairs or additions required.] officers have exercised their 11. Plumb' repairs or additions 3.❑ I am a homeowner doing all work ❑Plumbing myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs ,/ insurance required.]t c. 152,§1(4),and we have no 13.(l]�ther �yy41�C employees. [No workers' comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: National Grange Mutual Insurance Policy#or Self-ins.Lic #: WGT1090D Expiration Date: 1/19/21.# Job Site Address: �'�`� Sr City/State/Zip: JAA(0 G O Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereb y cern nder the p r s and penalties of perjury that the information provided above is true and correct. _ Si lure: � Date: ZJ Q Phone#: 413-427-1416 Official use only. Do not write in this area,to he completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): 1❑Board of Health 211 Building Department 31]City/Town Clerk 4.0 Electrical Inspector 50PIumbing Inspector 6.❑Other Contact Person: Phone#: 5005743-YTG-C-0815 DESCRIPTION 4 These indoor coils are designed to be installed with UPG furnaces or modular air handlers and matched with UPG cooling and heat pump outdoor units. All coil models are . 2YOR available as"flex-coil" units without a factory installed metering device. Flex-coil models allow these coils to be used with R- 410A or R-22 for added flexibility to meet refrigerant system choice. A piston or TXV metering device should be installed in the field to meet your system requirements. CF Models, Full Case Coils - Full cased coils are suitable for TECHNICAL GUIDE use in upflow or downflow applications. CM Models, Multi-Position Coils - CM coils have the added ADD - ON COILS flexibility that allow them to be installed in any position-upflow, FOR USE WITH SPLIT-SYSTEM downflow, or horizontal (right or left). This coil can be easily installed with a UPG furnace or modular air handler in any COOLING & HEAT PUMPS configuration. CM, CU CU Models, Uncased Coils - These coils are designed for MODELS: CF installation on top of upflow furnaces, and they are to be used 600 -2000 CFM 1.5 -5 TON COILS for upflow only applications. The uncased coils require field modification of the furnace duct for the coil installation. FEATURES m RC2 - Rigid Case Construction interior endoskeleton for structural support,flush side,and locks in insulation. Powder-painted-G30 galvanized steel case provide a coated edge that resists corrosion and rust creep. MaxAlloyTM Coil - Long life aluminum coils built to deliver lasting performance,efficiency and reliability. UPFLOW Quality Construction - Structural components are made of UNCASED Aluminum or G90 galvanized steel to prevent corrosion. CU Improved Insulation Design - Single piece with no external screws to reduce thermal transmission paths to prevent sweating. Foil faced insulation for ease of cleaning. Thermostatic Expansion Valve - Bolt-on TXV provides easy installation to convert the indoor coil to the required refrigerant that does not require brazing to replace or install. Some models are available with factory installed TXVs. ' Case Depth - These models have 20.5' casing which provide UPFLOW/DOWNFLOW FULL CASED ease of attic access and tight applications. FULL CASED MULTI-POSITION Thermoset Drain Pan - Positive slope for drainage to reduce CF CM A0368-M, cause for potential mold or contaminants. 11 ACCESSORIES * �9 Refer to Price Manual for specific model numbers. TXV Kits -Thermal expansion valve kits are available for flex- coil applications with R-410A refrigerant. All TXV kits are non- braze. All connections are bolt-on including the valve assembly and equalizer tube. No orifice or any other metering device is to AMERICAN ® ,5�� ,l` be used in conjunction with the TXV. QUALITY 'Hkn Kl;r;islx`` Partial Case—Available to be used with CU coils in four widths. MIGNEG,ENQINUM A IS0900t This option is intended for upflow applications where height ASSENIKEO IN THE USA C US Certified Quality limitations in the application prevent the installation of full cased - Management System coils. The partial case design allows the top section of the indoor coil to be installed in the duct or plenum. Due to continuous product improvement, Coil Casing Without Coil - Coil casings are available in four specifications are subject to change without notice. widths that can be installed with the furnace or modular air handler during initial installation.This option is available to allow Visit us on the web at: the installer the flexibility to add the coil at a later date without www.upgnet.com and www.york.com duct modifications. UVC Germicidal Light - The UVC technology effectively Additional rating information can be found at: prevents mold, bacteria, and other microorganisms that WWW.ahrid irecto .Or develop in air handling systems. The UVC Light Kit provides 9 safe, continuous cleaning while actually saving money by reducing HVAC system maintenance and energy consumption. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE MODEL TR200 P�S& (Energy Recovery Ventilators - ERV) HVI C UL US CERTIFIED LISTED DUCTED HEAT .> RECOVERY VENTILATOR 89S5 NOW Specifications Performance 7 Ventilation Type:Static Plate,Heat and Humidity Transfer A i r f I o w T o t a I T o t a I Typical Airflow Range: 100-200 CFM CFM ESP in HZO Temp EFF% EFF% EFF% Winter* Summer* Unit may be mounted in any orientation 122 0.70 81 77 64 Number Motors:One,0.1 hp 149 0.60 79 75 61 V Hz Phase Input Watts FLA 168 0.50 78 73 59 120 60 Single 157 @ 181 CFM 1.5 176 0.40 78 72 59 Control Voltage:24 VAC 186 0.30 77 72 58 Filters:2 MERV 8,spun polyester media. 10-1/2"x 21-3/4"x V 192 0.20 77 71 57 Weight:68 lbs(unit), 110 lbs(in carton) 207 0.10 76 70 56 Shipping Dimensions:34"L x 44"W x 34"H Contact Factory for HVI certification report for complete certified rating. Dimensions ABBREVIATIONS EA:Exhaust Air to outside OA:Outside Air intake 33 1/4"Overall RA:Room Air to be exhausted FA:Fresh Air to inside 2 1/4"Typ. 28 3/4"Case INSTALLATION ORIENTATION Unit may be installed in any orientation. NOTE O. LUNLESS OTHERWISE SPECIFIED. N'm _ DIMENSIONS ARE ROUNDED TO THE O O YT NEAREST EIGHTH OF AN INCH. 00= p } }m N; u TOP VIEW 0 m` o m yC 22 1/4"Minimum cService Area a _ (Door can be bo oRemoved from c4 ; 06'Nominal 34"Line Cord a Hinges.) TYP7. 23 7/8"Case T I; I �;---------- - OA Eq E m ) m yi' 7 2 1 W U ° _� � ; Door p _U O co c ( ' Swing o J— �8"Nominal m Typ. Pressure Ports 24V AC� (4)Typ. Control n � Terminal LEFT VIEW FRONT VIEW RIGHT VIEW SOIer&PalaU% All specifications are subject to change without notice unless approved in submittal by S&P. %Ventilation Group TR200 Submittal-052119 5129602-BTG-B-1115 DESCRIPTION TE{ HNIn- AL These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized steel tubular primary heat exchangers. The units are factory shipped for U111.1 installation in upflow or horizontal applications and may be con- verted for downflow applications. These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and 96%AFUE TWO STAGE STANDARD ECM are also ideal for commercial applications. All units are factory RESIDENTIAL GAS FURNACES assembled, wired and tested to assure safe dependable and economical installation and operation. MULTI-POSITION These units are Category IV listed and may be vented either MODELS: TM9Y through side wall or roof applications using approved plastic NATURAL GAS combustion air and vent piping. 40 -120 MBH INPUT FEATURES • Two stage heating operation includes two stage gas valve, )? two stage inducer operation and constant torque standard ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat. • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. • Compact, easy to install, ideal height 33"tall cabinet. • Standard ECM constant torque drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code display. ®� Low unit current draw requirement for easy replacement /^ application. \, All models are convertible to use propane(LP)gas. polyflue- Electronic Hot Surface Ignition saves fuel use with increased dependability and reliability. • 100% shut off main gas valve for extra safety. • 24V, 40 VA control transformer and integrated furnace con- trol supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat n rso �o� exchanger for outstanding efficiency. r� �OREGISG5 ' Solid removable bottom panel allows easy conversion. lso 9001 Airflow leakage less than 1% of nominal airflow for duct Sp Certified Quality blaster conditions. Management system No knockouts to deal with, making installation easier. Due to continuous product improvement,specifications are Movable duct connector flanges for application flexibility. subject to change without notice. Quiet inducer operation, burner, and blower operation. Visit us on the web at www.york.com Inducer rotates for easy conversion of venting options. Additional rating information can be found at Fully supported blower assembly for easy access and www.ahridirectoW.org removal of blower. • External air filters used for maximum flexibility in meeting WARRANTY SUMMARY customers IAQ needs. A 20-year limited warranty on heat exchangers in residen- Insulated blower compartment for thermal and acoustic per- tial applications. formance. A 10-year warranty on the heat exchanger in commercial 1/4 turn knobs provided for easy independent door removal. applications. Internal condensate trap design (patent pending) provides Standard 5-year limited Parts warranty. condensate management options and is self priming to pre- Extended lifetime heat exchanger and 10-year limited vent nuisance problems. parts warranty when product is registered online within Protection included from air intake, exhaust vent or conden- 90 days of purchase for replacement or closing for new sate blockage. home construction. See Limited Warranty certificate in Users Information Manual for details. Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 5129599-YTG-C-1016. LEFT SIDE FRONT RIGHT SIDE Combustion Air Inlet Combustion Air Inlet Condensate Drain - Gas Pipe (Downflow) p Entry Gas Pipe Condensate Drain Entry �^(pownflow) ' Vent Outlet .0,0 Electrical Electrical Entry Entry Vent Outlet Condensate CD Drain ® ® 33 Condensate r � ® ® 23" 10, 1 Thermostat Wiring o Drain r Thermostat Wiring Optional Return Air 14 Cutout(Either side) W U W 1" L J L J .28.5" A 29. ►�I i� ---*j 1.5" ss �-- 23.8" 0 3" Vent Outlet B Combustion B Air Inlet C 56" 56' i 24.25"-� 20" RETURN END SUPPLY END Cabinet&Duct Dimensions Cabinet Dimensions Inches Approximate Nominal Cabinet (inches) Model Operating Weights Size CFM(m3/min) A B C Lbs TM9Y040A10MP11 1000 A 14-1/2 13-3/8 11-3/4 113 TM9Y060612MP11 1200 B 17-1/2 16-3/8 13-1/4 119 TM9Y080B12MP11 1200 B 17-1/2 16-3/8 14-3/4 123 TM9Y080C16MP11 1600 C 21 19-7/8 16-1/2 130 TM9Y100C16MP11 1600 C 21 19-7/8 18-1/4 136 TM9Y100C20MP11 2000 C 21 19-7/8 18-1/4 143 TM9Y120D20MP11 2000 D 24-1/2 23-3/8 21-3/4 154 Ratings&Physical/Electrical Data Input Output Total AFUE High Fire Low Fire Model High/Low High/Low Unit Air Temp.Rise Air Temp.Rise MBH MBH Amps % "F °F TM9Y040A10MP11 40/26 38/25 9.5 96 25-55 25-55 TM9Y060B12MP11 60/39 58/37 9.5 96 35-65 35-65 TM9Y080B12MP11 80/52 77/50 9.5 96 45-75 35-65 TM9Y080C16MP11 80/52 77/50 9.5 96 40-70 25-55 TM9Y100C16MP11 100/65 96/62 9.5 96 50-80 30-60 TM9Y100C20MP11 100/65 96/62 10.9 96 45-75 30-60 TM9Y120D20MP11 120/78 115/75 10.9 96 50-80 45-75 Max.Outlet Blower Blower Size Max. Min.Wire Size Model Air Temp. Over-current (awg)@ 75 ft. °F HP Amps In. Protect One Way TM9Y040A10MP11 190 1/2 6.8 11 X8 15 14 TM9Y060612MP11 190 1/2 6.8 11 X8 15 14 TM9Y0801312MP11 190 1/2 6.8 11 X8 15 14 TM9Y080C16MP11 190 1/2 6.8 11 x 10 15 14 TM9Y100C16MP11 190 1/2 6.8 11 x 10 15 14 TM9Y100C20MP11 190 3/4 8.4 11 x 11 15 14 TM9Y120D20MP11 190 3/4 8.4 11 x 11 15 14 Annual Fuel Utilization Efficiency(AFUE)numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code(NFPA-704atest edition)and all local codes. The furnace shall be installed so that the electrical components are protected from water. 2 Johnson Controls Unitary Products 5146416-YTG-B-1215 DESCRIPTION � ' The YCD models are the latest iteration in our successful LX Series split system air conditioner lineup. Optimized for the 13 SEER Regional Minimum Efficiency in the North US and Can- YORK ada, these outdoor units are specifically designed to be matched with Johnson Controls Unitary Products indoor coils, furnaces, and air handlers to provide a complete system solu- tion. TECHNICAL GUIDE -N F&r"A�N,DA FEATURES LX SERIES # • Small Footprint - Minimum footprint for easier handling, SPLIT SYSTEM transportation,and installation. • Easier Installation - Independent panels provide quick AIR CONDITIONERS °'" Ui."""ONed access for unit setup. Installation time is reduced by easy 13 SEER — R-41 OA — I PHASE power and control wiring access. Options are provided for indoor piston or TXV.The factory installed filter-drier and fac- 1.5 THRU 5 NOMINAL TONS tory charge for a 15-Ft lineset means less time spent brazing MODELS: YCD18 THRU 60 and charging the system. The small base dimension and reduced unit clearances make for easier retrofits. • Accessible Information - QR code on unit provides quick access to technical documents and warranty information. • Durable Finish - The coated steel wire fan guard, coated � ,a„ •��"y "r: external fasteners, and pre-treated G90-equivalent galva- 141. nized steel chassis components resist corrosion and rust : �... '! _ `�'�•` creep.Champagne colored powdercoat paint further protects external panels. Quality Coils -The high efficiency microchannel aluminum coil is manufactured using an improved material system pro- viding reliable performance and small unit size. Rugged Coil Protection -Coils are protected from mechan- ical n- ical damage by a proven stamped steel coil guard design. Protected Compressor - Compressors are protected inter- .: .. nally by a high pressure relief valve and a temperature sen- sor, and externally by the system high pressure switch. The liquid line filter-drier is factory installed to protect the com- pressor against moisture and debris. q Gwif Reliable Operation - Ball bearing fan motors provide supe- .�,.. nor performance in extreme temperatures. • Environmentally Friendly - CFC-free R-410A refrigerant AMERICAN delivers environmentally friendly performance with zero QUALITY ozone depletion. DESIGNED,ENGINEERED k . Top Discharge-Warm air is blown up, away from the struc- Itl:l:l��k ASSEMBLED IN THE USA Iso 9001 ture and any landscaping and allows compact location on Certified Quality C US multi-unit applications. Management System • Low Operating Sound Levels - Developed using CFD and Due to continuous product improvement,specifications FEA tools,the sturdy cabinet and top design provides sound are subject to change without notice. performance of 77 dBA or lower. Compatible accessories for Visit us on the web at further sound reduction are also available. www.upgnetcom and www.york.com • Better Service Access - Diagonal base valves with open Additional rating information can be found at access for low-loss fittings, single panel access to the electri- www.ahridirectory.orq cal controls, swing out control box for full corner access, and removable fan guard allow easy access for unit mainte- WARRANTY SUMMARY* nance. Standard 5-Years limited parts warranty. Agency Listed - Safety certified by CSA to UL 1995/CSA Standard 10-Years limited compressor warranty. 22.2. Performance certified to ANSI/AHRI Standard 210/240 Extended 10-Years limited parts warranty when product is in accordance with the Unitary Small Equipment certification registered online within 90 days of purchase for replacement program. or closing for new home construction. *Does not apply to R-22 models,3-Phase models,or Internet sales. See Limited Warranty certificate in User's Information Manual for details. FOR DISTRIBUTION USE ONLY-NOT TO BE USED AT POINT OF RETAIL SALE 5146416-YTG-B-1215 PHYSICAL AND ELECTRICAL DATA MODEL YCD18 YCD24 YCD30 YCD36 YCD42 YCD48 YCD60 B21(H,S) B21(H,S) B21(H,S) B21(H,S) B21(H,S) 621S B21S Unit Supply Voltage 208-230V, 1�,60Hz Normal Voltage Range 187 to 252 Minimum CircuitAmpacity 9.6 12.3 14.2 19.9 21.9 28.5 34.3 Max.Overcurrent Device Amps 2 15 20 20 30 35 50 60 Min. Overcurrent Device Amps 3 15 15 15 20 25 30 35 Compressor Type Recip Recip Recip Recip Recip Scroll Scroll Compressor Rated Load 7.0 9.2 10.7 14.7 16.5 21.8 26.4 Amps Locked Rotor 45.0 45.0 57.0 78.0 88.0 117 134 Crankcase Heater No No No No No No No Factory External Discharge Muffler No No No No Yes No No HS Kit Required with TXV 4 Yes* Yes* Yes* Yes* Yes* No No Fan Diameter Inches 18 18 18 18 22 22 22 Rated HP 1/8 1/8 1/8 1/4 1/4 1/4 1/4 Fan Motor Rated Load Amps 0.80 0.80 0.80 1.50 1.30 1.30 1.30 Nominal RPM 1075 1075 1075 1100 850 850 850 Nominal CFM 1925 1950 2150 2575 2925 3225 3350 Face Area Sq. Ft, 8.26 9.78 11.07 12.37 12.22 13.83 17.37 Coil Rows Deep 1 1 1 1 1 1 1 Fins/Inch 23 23 23 23 23 23 23 Liquid Line Set OD(Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD(Field Installed)5 3/4 3/4 3/4 3/4 7/8 7/8 1-1/8t Unit Charge(Lbs.-Oz.)6 2- 15 3-4 3-13 4-1 4-6 4-8 5-6 Charge Per Foot,Oz. 0.62 0.62 0.62 0.62 1 0.67 0.67 0.75 Operating Weight Lbs. 1 125 1 130 1 140 140 175 165 175 Models with"H"on the end of the model number are shipped with a Hard Start Kit installed at the factory. 1. Rated in accordance with AHRI Standard 110-2012,utilization range"A'. 2. Dual element fuses or HACR circuit breaker.Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker.Minimum recommended overcurrent protection. 4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model. 5. For applications with non-standard vapor line sizes,see the'Applications&Accessories"section of this Technical Guide. 6. The Unit Charge is correct for the outdoor unit,smallest matched indoor unit,and 15 feet of refrigerant tubing.For tubing lengths other than 15 feet,add or subtract the amount of refrigerant,using the difference in actual lineset length(not the equivalent length)multiplied by the per foot value DIMENSIONS C Dimensions Refrigerant Connection Unit (Inches) Service Valve Size Model A B C Liquid Vapor YCD18B21(H,S) 23-1/2 1 24 24 O0� YCD24B21(H,S) 26-3/4 24 24 3/4 YCD30B21(H,S) 30 24 24 A p0� YCD36B21(H,S) 33-1/4 24 24 3/8 Q QQ YCD42B21(H,S) 26-3/4 29-1/4 29-1/4 7/8 YCD481321S 30 29-1/4 29-1/4 IF O 0 YCD601321S 361/4 29-1/4 29-1/4 7/8$ 0� $Adapter fitting must be field installed for the required 1-118"line set. All dimensions are in inches and are subject to change without notice. B Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads. Johnson Controls Unitary Products 3