Loading...
HERS-1024 19 Higgins Way - Air Leakage ReportAir Leakage Report Property 19 Higgins Way Northampton, MA 01060 HERS -1024 19 Higgins Way confirmed Organization Inspection Status Power House Energy Con: 2020-03-16 Rafael Loveszy Rater ID (RTIN): 5182405 RESNET Registered Builder (Confirmed) The Pecoy Companies General Information Conditioned Floor Area [sq. ft.] 3,601.5 Infiltration Volume [cu. ft.] 28,474.9 Number of Bedrooms 3 Air Leakage Measured Infiltration 1019.6 CFM50 (2.15 ACH50) ACH50 (Calculated) 2.15 ELA [sq. in.] (Calculated) 56.08 ELA per 100 s.f. Shell Area (Calculated) 0.734 CFM50 (Calculated) 1,020 CFM501 s.f. Shell Area (Calculated) 0.133 Duct Leakage Mechanical Ventilation Rate [CFM] System 1 Leakage to Outdoors 0 CFM @ 25Pa (01100 s.f.) Total Leakage Test Type Post -Construction Total Leakage [CFM @ 25 Pa] 193.0 Total Leakage [CFM251 100 s.f.] 5.4 Total Leakage [CFM251 CFA] 0.054 Mechanical Ventilation Rate [CFM] 60 CFM Hours per day 24.0 Fan Power 50 Watts Recovery Efficiency % 60.0 Runs at least once every 3 hrs? true Average Rate [CFM] 60.0 CFM 2010 ASH RAE 62.2 Req. Cont. Ventilation 66.0 2013 ASHRAE 62.2 Req. Cont. Ventilation 103.6 Ekotrope RATER - Version 3.2.3.2394 All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. rj ='OWER HOUSE LNERGTCOMULTRiG