36-382 (2) 230 EMERSON WAY SM-2020-0027 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 11786 Map: 36 i Bock:Lot: 001 SHEETMETAL PERMIT Permit: SHEETMETAL Category: 'SHEETMETAL, Permit# !SM-2020-0027 PERMISSION IS HEREBY GRANTED TO: Project# 1"JS-2020-000536 Est.Cost: ;$17,000.00 Contractor: License: Expires: Fee Charged:S50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020 Balance Due:$.00 Owner: ROSEMUND LLC #of Fixtures:F Applicant: ROCK VALLEY HVAC DigSafe# AT: 230 EMERSON WAY UseGroup ConstClass ISSUED ON: 12-Feb-2020 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK.- HVAC ORK:HVAC THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2020-002560 I I-Feb-20 1287 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck(a-northamptonma.gov GeoTMS®2020 Des Lauriers Municipal Solutions,Inc. Commonwealth of Massachusetts 1 Permit Date: 2/10/2020 it Estimated Job Cost: $17,00FEB 20 601 1 20 P rmit ee: $ � * -7 1 Plans Submitted: YES I NO Plans su,ta,N�ins ans eviewed: YES NO HA MnTC� MgpECTIpNS Business License #824 01060 1 cant License # SM2626 Business Information: Property Owner/Job Location Information: Name: Jesse Fortier (Rock Valley HVAC) Name: Rosemund Homes Street: 296C Nonotuck Street Street: 230 Emerson Way City/Town: Florence City/Town: Northampton Telephone: (413) 535-7804 Telephone: (413) 695-4195 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family V Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stories:2 Sheet metal work to be completed: New Work: ✓ Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney /Vents Air Balancing Provide detailed description of work to be done: Provide and install complete HVAC system. 2nd floor system contains (3) Mitsubishi MSZ-FH06NA wall mounted ductless units, 1St floor contains (1) Mitsubishi SVZ-KP24NA ducted air handler. All indoor units connecting to (1) Mitsubishi MXZ-5C42NAHZ heat pump. Fabricate and install ductwork for 1 st floor air handler. Ductwork to be run in conditioned space, sealed, and insulated in accordance with state and local code. INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes ZNo ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy 0 Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waives this requirement. _ Check One Only Owner Agent ❑ Signature of Owner or Owner's Agent By checking this boxy,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Prol4ress Inspections Date Comments Final Inspection Date Comments Type of License: By Master — Title ❑ Master-Restricted -- City/Town ❑ Journeyperson Signature of Licensee Permit# ❑ Journeyperson-Restricted License Number_ ✓1 Fee$ ❑ Check at www.mass.gov/dpi Ins ector Signature of Permit A roval �� ✓�� Project Summa Job. wrightsoft Date: Aug 07,2019 Entire House By: Rock Valley HVAC Inc. 296C Nonotuck Street,Florence,Ma 01062 Phone:(413)535-7804 Email:rockvalleyhvacCo yahoo.com Web:www.rockvalleyhvac.com License:SM2626 Project • • For: Rosemund Homes 230 Emerson Way, Northampton, Ma 01060 2nd floor hvac system contains(3)Mitsubishi wall mounted indoor units. 1st floor hvac system contains(1)Mitsubishi SVZ air handler. Notes: All indoor units going to(1)Mitsubishi MXZ-5C42NAHZ heat pump. AHRI attached Desiqn Information Weather: Greenfield (Worcester Dd), MA, US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 'F Daily range M Relative humidity 50 % Moisture difference 42 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 19568 Btuh Structure 12106 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh piping 0 Btuh Equipment load 19568 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 10895 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tight) Structure 553 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 1645 1645 Equipment latent load 553 Btuh Volume (ft) 13160 13160 Air changes/hour 0.18 0.09 Equipment Total Load (Sen+Lat) 11448 Btuh Equiv. AVF (cfm) 39 20 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 854 cfm Actual air flow 854 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.071 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -r"d- wright- 2020-Feb-10 10:26:10 Right-SuiteOO Universal 2019 19.0.12 RSU24598 Page ers\thero\Desktop\Heat Loads\Rosemund Brown.rup Calc=MJ8 Front Door faces: N First floor conditioned with Mitsubishi SVZ-KP24NA air handler and conventional ductwork. Air handler to be connected to Mitsubishi MXZ-5C42NAHZ heat pump. IJ`c� �S Level 1 AW( �allot ( Master Bath 'n ba e nd Master Bej t Linein Ent Laundr WIC Open Garage STR CL Offi PWD Job#: Rock Valley HVAC Inc. Scale: 1 : 87 Performed for: Page 2 Rosemund Homes 296C Nonotuck Street 230 Emerson Way RightSuite®Universal 2019 Northampton,Ma 01060 Florence,Me 01062 19.0.12 RSU24598 Phone:(413)535-7804 2020-Feb-10 10:25:52 www.rockvalleyhvac.com rockvalleyhvac@yahoo.com ...op\Heat Loads\Rosemund Brown.ru 2nd floor has(3)Mitsubishi MSZ-FH06NA wall mounted indoor units. All indoor units going to(1)Mitsubishi MXZ-5C42NAHZ heat pump Level 2 Mitsubishi MSZ-FH06NA wall Mitsubishi MSZ-FH06NA wall mounted indoor unit mounted indoor unit Bedroom#2 Bedroom#3 Bathroon CIO! Hal Clos STR2 Mitsubishi MSZ-FHO6NA wall mounted indoor unit Open to Belo Bedroom 44 Job#: Rock Valley HVAC Inc. Scale: 1 : 87 Performed for: Page 1 Rosemund Homes 296C Nonotuck Street 230 Emerson Way RightSe uit ®Universal 2019 Northampton,Ma 01060 Florence,Ma 01062 19.0.12 RSU24598 Phone:(413)535-7804 2020-Feb-10 10:25:52 www,rockvalleyhvac.com rockvalleyhvac@yahoo.com ...op\Heat Loads\Rosemund Brown.rup ANERLS CERTIFIED www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:201755022 Date:02-10-2020 Model Status:Active AHRI Type:HRCU-A-CB Series Name:M-Series Outdoor Unit Brand Name:Mitsubishi Electric Outdoor Unit Model Number: Indoor Type:Mixed Ducted and Non-Ducted Indoor Units Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1,Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third parry testing: Cooling Capacity(95F):42000 EER(95F):12.10 SEER:17.00 High Heat(47F):48000 Low Heat(17F):36200 HSPF:10.55 Sold in?:USA t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced"Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)ratino. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahrldirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and It confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,In any form or manner or by any means,except for the user's Individual, Ad N! personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. 132258222257324318 ©2020Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO,: --, CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) `-� 02/10/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT 14A E. K.S.K.INSURANCE AGENCY,INC. PHONE 413 527-7859I FAX ( 413 527-8314 203 Northampton St. . E-MAIL . travissias ksk-insurance.com P.O.Box 597 INSURERS AFFORDING COVERAGE NAIC# Easthampton MA 01027 INSURER A: SAFETY INSURANCE INSURED INSURER B: SAFETY INDEMNITY INS CO Rock Valley Heating and Air Conditioning Inc INSURER C: STARSTONE NATIONAL INS CO 296C Nonotuck St INSURER D: WESCO INSURANCE CO Florence MA 01062 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP JJJL POLICY NUMBER LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE X❑OCCUR DIR AMAGE., RENTED $50,000 BMA0024116 08/28/2019 08/28/2020 MED EXP(Any one arson 10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 X POLICY❑PRO- JECT F_�LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1 MIL CSL B ANY AUTO BODILY INJURY(Per person) $ ALL OWNEDx SCHEDULED AUTOS AUTOS 6234640 08/10/2019 08/10/2020 BODILY INJURY(Per accident) $ X HIRED AUTOS x NON-OWNED PROPERTY DAMAGE $ AUTOS $ UMBRELLA LIAB X OCCUR EACH OCCURRENCE 10,000,000 C X EXCESS LIAR CLAIMS-MADE 78912R190ALI 08/10/2019 08/10/2020 AGGREGATE $10,000,000 DED X I RETENTION$10,000 Prod/Comp Ops A $10,000,000 WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY ANY D OFFICER/MEMBER EXCLUDED?ECUTIVE Y I❑ N/A WWC3432563 08/12/2019 08/12/2020 E.L.EACH ACCIDENT $500 000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $500 OOO If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT I$500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) HEATING AND AIR CONDITIONING INSTALLATION,MAINTANENCE REPAIR CERTIFICATE HOLDER CANCELLATION City Of Northampton SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 212 Main Street ACCORDANCE WITH THE POLICY PROVISIONS. Northampton MA 01060 AUTHORIZED REPRESENTATIVE f '- ♦ /j//,r/.�'''''/) <DA> ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD