Loading...
36-369 (4) 163 EMERSON WAY SM-2020-0026 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON GIS#: 11773 Map: 36 ? 1 Block: 369 {' r -., SHEETMETAL PERMIT Lot: 001 Permit: SHEETMETAL Category: ',SHEETMETAL Permit# ISM-2020-0026 Project# JS-2019-002425 PERMISSION IS HEREBY GRANTED TO: Est.Cost: $22,000.00 Contractor: License: Expires: Fee Charged:$50.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2020 Balance Due:$.00 Owner: KENNAMER HAL #of Fixtures:: Applicant: ROCK VALLEY HVAC DigSafe# AT. 163 EMERSON WAY UseGroup ConstClass ISSUED ON: 12-Feb-2020 AMENDED ON: EXPIRES ON. TO PERFORM THE FOLLOWING WORK: HVAC SYSTEM THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal REC-2020-002558 II-Feb-20 1291 $50.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck a northamptonma.gov GeoTMS%2020 Des l.auriers Municipal Solutions,Inc. Commonwealth of Massachusetts Sheet Metal Permit 4�c''� Date: 2/10/2020 Permit# FEB Estimated Job Cost: $22,000 Permit Fee: $ 60 `x/29/ ' 20CT ,. �nJSp Plans Submitted: YES NO Plans Reviewed: YES NO �. oN Mq F�r, X7060 Business License #824 Applicant License# SM2626 Business Information: Property Owner/Job Location Information: Name: Jesse Fortier(Rock Valley HVAC) Name: FCM Smart Build Street: 296C Nonotuck Street Street: 163 Emerson Way City/Town: Florence City/Town: Northampton Telephone: (413) 535-7804 Telephone: (413) 588-8975 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family ✓ Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. ✓ over 10,000 sq. ft. Number of Stories:I I Sheet metal work to be completed: New Work: ✓ Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide and install complete HVAC system. Bedroom zone contains (1) Mitsubishi PEAD-A 12AA7 ducted air handler, Main house zone contains (1) Mitsubishi SVZ-KP18NA ducted air handler,basement is conditioned with(1) Mitsubishi MSZ-FH06NA wall mounted indoor unit. All indoor units to be connected to (1)Mitsubishi MXZ-4C36NAHZ2 heat pump. Fabricate and install ductwork for(2) ducted air handlers. Ductwork to be run in conditioned space, sealed, and insulated in accordance with state and local code. INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes nNo ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy 0 Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: lam aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waives this requirement. Check One Only Owner Agent ❑ � Signature of Owner or Owner's Agent By checking this boxE, I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.. Duct inspection required prior to insulation installation: YES NO I` Yrol4ress Inspections Date Comments Final Inspection Date Comments Type of License: 1 By [ Master Title ❑ Master-Restricted City/Town ❑ Journeyperson Signature of Licensee Permit# ❑ Journeyperson-Restricted License Number: Fee$ ❑ Check at www.mass.gov/dpi In ector Signature of Permit proval /// Project Summa Job: wrightsoft 1 Date: Jun 06,2019 Entire House By: Rock Valley HVAC Inc. 296C Nonotuck Street,Florence,Ma 01062 Phone:(413)535-7804 Email:rockvalleyhvac@yahoo.com Web:www.rockvalleyhvac.com License:SM2626 Project Information For: FCM Smart Build 163 Emerson Way, Northampton, Ma 01060 Phone: (413) 588-8975 Email: ferrarl.steve( gmail.com Notes: Bedroom zone conditioned wl (1)Mitsubishi PEAD-Al2AA7 ducted air handler. Main house conditioned with(1)Mitsubishi SVZ-KP18NA ducted air handler Basement conditioned with(1) Mitsubishi MSZ-FH06NA ductless wall mounted indoor unit. All indoor units connected to(1)Mitsubishi MXZ-4C36NAHZ2 heat pump. Design Information Weather: Greenfield (Worcester Dd), MA, US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 °F Daily range M Relative humidity 50 % Moisture difference 42 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 22738 Btuh Structure 10254 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22738 Btuh Use manufacturer's data in Rate/swing multiplier 0.90 Infiltration Equipment sensible load 9228 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Tight) Structure 477 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 2128 2128 Equipment latent load 477 Btuh Volume (ft') 17024 17024 Air changes/hour 0.11 0.06 Equipment Total Load (Sen+Lat) 9705 Btuh Equiv. AVF (cfm) 31 17 Req. total capacity at 0.70 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80 AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 724 cfm Actual air flow 724 cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.071 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriyhtsott 2020-Feb-1011:25:03 Right-Suite@ Universal 2019 19.0.12 RSU24598 Pagel sers\thero\Desktop\Heat Loads\FCM Kennemaer.rup Calc=MJ8 Front Door faces: N N Bedroom zone conditioned with (1) Mitsubishi PEAD-Al2AA7 ducted air handler. Main house conditioned with (1) Mitsubishi SVZ-KP18NA ducted air handler Basement conditioned with (1) Mitsubishi MSZ-FH06NA ductless wall mounted indoor unit. All indoor units connected to (1) Mitsubishi MXZ-4C36NAHZ2 heat pump. All ductwork to be run in conditioned space. Ductwork to be sealed and insulated in accordance with state and local code. Level 1 STR Mudroon Dinina/Kitcher Livinq Roon Hall 2 Dressim Master Batt Entry WIC Clos Pantry/Laundry Hall Bed m: Bedtoom i Mast r th t� ■� 5�����c N1;��b� 5�,, It�-r�n-Aia��7 Job#: Rock Valley HVAC Inc. Scale: 1 : 92 Performed for: Page 1 FCM Smart Build 296C Nonotuck Street Right-Suite@ Universal 2019 163 Emerson Way Florence, Ma 01062 19.0.12 RSU24598 Northampton,Me 01060 Phone:(413)58 588-8975 Phone:(413)535-7804 2020-Feb-10 11:24:46 ferrari.steve@gmail.com www.rockvalleyhvac.com rockvalleyhvac@yahoo.car ...top\Heat Loads\FCM Kennemaer.i This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. also on al C E RT I www.ahridiretory.org Certificate of Product Ratings AHRI Certified Reference Number:201755020 Date:02-10-2020 Model Status:Active AHRI Type: HRCU-A-CB Series Name: M-Series Outdoor Unit Brand Name:Mitsubishi Electric Outdoor Unit Model Number:MXZ-4C36NAHZ Indoor Type :Mixed Ducted and Non-Ducted Indoor Units Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(95F):36000 EER(95F): 12.65 SEER: 17.45 High Heat(47F):45000 Low Heat(17F):35000 HSPF: 10.70 Sold in?:USA t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale,OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering far sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced:copied:disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING.BEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above.and the Certificate No.,which is listed at bottom right. ©2020Air-Conditioning, Heating,and Refrigeration Institute [CERTIFICATE NO.: 132258258689583084 CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) �-- 02/10/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT ME K.S.K.INSURANCE AGENCY,INC. PHONE 413 527-7859 FAx 413 527-8314 203 Northampton St. EA Ess.-MAIL travissias ksk-insurance.com P.O. Box 597 INSURER(S)AFFORDING COVERAGE NAIC# Easthampton MA 01027 INSURERA: SAFETY INSURANCE INSURED INSURER B: SAFETY INDEMNITY INS CO Rock Valley Heating and Air Conditioning Inc INSURER C: STARSTONE NATIONAL INS CO 296C Nonotuck St INSURER D: WESCO INSURANCE CO Florence MA 01062INSURER E INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE L 1STED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP JJIL POLICY NUMBER LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE S1,000,000 A CLAIMS-MADE XOCCUR DAMAGE TO RENTED $50,000 BMA0024116 08/28/2019 08/28/2020 MED EXP(Any oneperson) $10,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE s2,000,000 X POLICY❑ PRO F LOC PRODUCTS-COMP/OP AGG s2,000,000 JECT OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1 MIL CSL B ANY AUTO BODILY INJURY(Per person) $ ALL OWNED x SCHEDULED 6234640 08/10/2019 08/10/2020 BODILY INJURY(Per accident) $ AUTOS AUTOS X HIRED AUTOS 7t NON-OWNED PROPERTY DAMAGE $ AUTOS UMBRELLA LIAB X OCCUR EACH OCCURRENCE S 1 O 000 000 C X EXCESS LIAB CLAIMS-MADE 78912R190ALI 08/10/2019 08/10/2020 AGGREGATE S 10,000,000 DED X I RETENTION$10,000 Prod/Comp Ops A $10,000,000 WORKERS COMPENSATION PERSTATUTE OTH- AND EMPLOYERS'LIABILITY D OFFICER/MEMBER EXCLUDPROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $500,000 I ER ANY O? YIN ❑N NIA WWC3432563 08/12/2019 08/12/2020 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $500,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) HEATING AND AIR CONDITIONING INSTALLATION, MAINTANENCE REPAIR CERTIFICATE HOLDER CANCELLATION City Of Northampton SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 212 Main Street ACCORDANCE WITH THE POLICY PROVISIONS. Northampton MA 01060 //} y AUTHORIZED REPRESENTATIVEJ�����y�V► DA> ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD