Loading...
12-012 (4) CS Beam 2018.9.0.16 2_ kmBeamEngine 2018.9.0.1 WllltelZlegleC 1� 16-t9 km Material,Database .9. 20 Country Way — 4:03pm Florence Ma. 1 of I Member Data Description: Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: 0.00 Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: U360 live. U240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 18.1 PLF Filename: 13ft 11 inBea Other Loads Type Trib. Other Dead (Description) Side Begin End Width Start End Start End Category Replacement Uniform(PSF) Top 0' 0.00" 15'11.50" 12' 2.00" 30 10 Live Additional Uniform(PLF) Top 0' 0.00" 15'11.50" 0 56 Livc Additional Uniform(PSF) Top 0' 0.00" 15'11.50" 12' 2.00" 0 10 Live Q 15 11 8 15„ s Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall LVUPSL(DF/SP) End-Grain(1000psi) N/A 1.500" 5495# 2 15'11.500" Wall SPF#3/Stud 2x or 4x End-Grain(650psi) N/A 1.610" 5495# Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 2939# 2556# 2 2939# 2556# Design spans 16' 1.250° Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Connect members with 2 rows of 16d common nails at 12.0"oc NOTE: Nails must be applied from both sides Minimum 1.50"bearing required at bearing#1 Minimum 1.61"bearing required at bearing#2 Design assumes continuous lateral bracing along the top chord. Design assumes maximum unbraced length of 0.00'along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 221234 33189.'# 66% 7.98' Total Load D+L Shear 4820.# 11845.# 40% 15.23' Total Load D+L TL Deflection 0.7048" 0.8052" 0274 7.98' Total Load D+L LL Deflection 0.3770" 0.5368" 0512 7.98' Total Load L Control: TL Deflection DOLS: Live=100% Snow=115% Roof=125% Wind=160°/ Design assumes a repetitive member use increase in bending stress: 4% All product names are trademarks of their respective owners Copyright(C)2018 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. "Passing is defined as when the member,floor joist,beam or girder.shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet The design must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation accordion to the manufacturersspecifications.