Loading...
06-038 (5) 319 HAYDENVILLE RD-Route 9 BP-2020-0773 GIs#: COMMONWEALTH OF MASSACHUSETTS MU:Block:06-038 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: ROOF BUILDING PERMIT, Permit# BP-2020-0773 Proiect# JS-2020-001337 Est.Cost:$14784.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO. Const.Class: Contractor: License: Use Group: VIVINT SOLAR DEVELOPER LLC 062490 Lot Size(sq. ft.): 11238.48 Owner: GRUNWALD JANET F Zoning: SR(100)/ Applicant: VIVINT SOLAR DEVELOPER LLC AT. 319 HAYDENVILLE RD - Route 9 Applicant Address: Phone: Insurance: 150 PADGETTE ST UNIT A - Attn Savina Cervone (413) 259-8044 () WC CHICOPEEMA01022 ISSUED ON:1/6/2020 0:00:00 TO PERFORM THE FOLLOWING WORK.-21 PANEL ROOF TOP SOLAR 6.72 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Sienature: FeeType: Date Paid: Amount: Building 1/6/2020 0:00:00 $75.00 212 Main Street,Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner k ✓ Department use only 9yof orthampton Status of Permit: 1QN _ 2 B ildin Department Curb Cut/Driveway Permit 2019 212 Main Street Sewer/Septic Availability Dom 100 Water/Well Availability r �t1N0/1Vr tF�SPF rtha pton, MA 01060 Two Sets of Structural Plans ^" I'aOFl fi 15871 1240 Fax 413-587-1272 Plot/Site Plans Other Specify i APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Provertv ProveAddress `r �J This section to be completed by office c319 Q� �V l IIv ' v Map Lot Unit J5, (Di(D5 Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record• an" j (31? zV4,J(50V-111e' 2a Name(Print) Cur g t aili ess Telephone Signature 2.2 Authorized Agent: Savina Cervone 150 Padgette St, Chicopee, MA 01022 Na (Print) Current Mailing Address 413-217-4033 Signature Telephone SECTION 3 -ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building g (a) Building Permit Fee 2. Electrical/ <7ei nen (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee C �J 4. Mechanical (HVAC) 5. Fire Protection 6. Total = 0 +2 + 3+4 + 5) Check Number 6) This Section For Official Use Only Building Permit Number: 7 Date Issued: Signature: / Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: ` volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DON'T KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DON'T KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservatibn Commission? Needs to be obtained O Obtained O Date Issued: C. Do any signs exist on the property? YES Q NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. a SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [M Siding [o] Other[O] Brief Description of Proposedf �S k W Inst 11 t' of r of mounted photovoltaic s lar systems# of modules tip lrt/lew;e MC10 ,H5 rmfi (YeH- live an Alteration of existing bedroom Yes o A ding new a room Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housina, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, Vivint Solar Developer, LLC as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Savina Cervone Print me Signature of Owner/Agent Dat SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Douglas Caverly CS-062490 License Number 150 Padgette St Unit B, Chicopee, MA 01022 03/02/2020 Address Expiration Date 413-259-8044 ' Signature Telephone 9.Registered Home Improvement Contractor: Not Applicable ❑ VIVINT SOLAR DEVELOPER, LLC/Douglas Caverly 170848 Company Name Registration Number 1800 W Ashton Blvd. Lehi UT 84043 1/4/2020 Address Expiration Date Telephone 413-259-8044 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work. The debris will be transported by: yivint Solar Developer, LLC The debris will be received by: yivint Solar Developer, LLC Building permit number: Name of Permit Applicant Savina Cervone Date Signature of Permit Applicant The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 600 Washington Street Boston, MA 02111 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Annlicant Information Please Print Leeibly Name(Business/Organization/Individual): Vivint Solar Developer.LLC _ Address: 1800 W Ashton Blvd City/State/Zip: Lehi, UT 84043 Phone #: 801-845-0286 Are you an employer? Check the appropriate box: Type of project(required): 1.® I am a employer with 253 4. ❑ I am a general contractor and I employees(full and/or part-time). have hired the sub-contractors 6. E]New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition workingfor me in an capacity. employees and have workers' y p �'• 9. EJ Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.[M Other Solar Installation comp. insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Zurich American Insurance Company _ Policy#or Self-ins. Lic.#: WC5096014-05 Expiration Date: 11/01/2020 Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the ins and enalhe perjury that the information provided above is true and correct Signature: Date: 11/20/2019 Phone#: 801-845-0 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone#: 1 Office of Consumer Afialrs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE: Supplement Card before the expiration date, If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 170848 01/04/2020 1000 Washington Street -Suite 710 VIVINT SOLAR DEVELOPER LLC. Boston,MA 02118 DOUGLAS CAVERLY 1800 W.ASHTON BLVD ,r.elCL js LEHI,UT 84043 Undersecretary Not valid out signature Commonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards Constr.4ctibii tUpgrvtsor CS-062490 Expires: 03102/2020 DOUGLAS P CAVERLY 34 SCHNEIDER ROAD SOMERS CT 06071 Commissioner gig 1 DATE(MMIDDIYYYY) AC" RO CERTIFICATE OF LIABILITY INSURANCE 22/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME` PHONE FAX 122517TH STREET,SUITE 1300 AIC.No.Eft (AIC,Nc): DENVER,CO 80202-5534 E-MAIL Attn:Denver.CertRequest@marsh.com Fax:212-948-4381 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC0 INSURER A:AXIS Specialty Eumpe SE INSVUIvinSolar Developer,LLC INSURER B:Zurich American Insurance Company 16535 1800 W Ashton Blvd INSURER C:American Zurich Insurance Company 40142 Lehi,UT 84043 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-003174122-21 REVISION NUMBER: 9 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL-THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. /NSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY NUMBER MMIDDIYYYY M LILY EXP TR LIMITS A �XL COMMERCIAL GENERAL LIABILITY 3776500119ES 12/0112019 11/01/2020 EACH OCCURRENCE $ 1,000,000 DA AGE TO RFNTFD- CLAIMS-MADE _X1 OCCUR PREMISES Ea occurrence $ 1,000,000 MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'LAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY E]PROJECT F]LOC PRODUCTS-COMP/OPAGG $ 1,000,000 OTHER $ H AUTOMOBILE LIABILITY SAP509601505 11101/2019 11/01/2020 COMBINED SINGLE LIMIT $ 1,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per acddent) $ AUTOS ONLY AUTOS _- X HIREDX NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident _- S X UMBRELLA LIAB X OCCUR 3776500219ES 12/01/2019 11/01/2020 EACH OCCURRENCE $ 5,000,000 EXCESS LAB I CLAIMS-MADE AGGREGATE $ 5,000,000 DED I I RETENTION$ $ C WORKERS COMPENSATION WC509601305(AOS) 1110112019 11/01/2020X PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER ANYPROPRIETORIPARTNER/EXg YIN WC509601405(MA) 11/01/2019 11/01/2020 1,000,000 OFFICER/MEMBEREXC UDED4ECUTIVE � NIA E.L.EACH ACCIDENT $ (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1000 000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION Town of Northampton SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 212 Main Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Northampton,MA 01060 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Jon Lindstrom ©1988-2016 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD vivin • sOI a i 1800 W Ashton Blvd. Structural Group Lehi, UT 84043 J. Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE- Civil Director of Engineering Structural Engineering Structural Engineering james.walsh@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vivintsolar.com December 26, 2019 Re: Structural Engineering Services Grunwald Residence 319 Haydenville Rd, Northampton, MA S-6283309; MA-04 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Sections (1a and 2a): Dimensional lumber-2x6 at 16"on center. Survey photos indicate that there was free access to verify the framing size and spacing. • Roof Section 3: Dimensional lumber- assumed 2x6 at 16" on center. Survey photos indicate that there was not free access to verify the framing size and spacing. • Roof Sections (1 b and 2b): Dimensional lumber-assumed 2x6 at 16"on center. Survey photos indicate that there was not free access to verify the framing size and spacing. B. Loading Criteria 11.13 PSF = Dead Load (roofing/framing) 3.00 PSF = Dead Load (solar panels/mounting hardware) 14.13 PSF =Total Dead Load 20 PSF = Roof Live Load 40 PSF = Ground Snow Load (based on local requirements) Wind speed of 117 mph (based on Exposure Category B-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. Page 1 of 2 v'v'nt• so I a r Page 2 of 2 • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website (www.ecofastensolar.com). 2. The solar panels are 1'/z" thick. At no time will the panels be mounted higher than 10" above the existing surface of the roof. 3. The following mounting types shall be used. Please refer to the mounting details for the associated required penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per connection and therefore is adequate. • EcoFasten with Rock-It: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS)of timber construction specifications for Spruce-Pine-Fir is 235 lbs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2015 IBC 2303.4.5 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible, to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 64 64 64 48 48 48 Max Uplift Load lbs 129 84 48 218 143 80 D. Summary Based on the above evaluation,with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2015 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, J. Matthew Walsh, PE MA License No. 54057 J- ATTt, NO. 54057 Q. �FG�STER�� �'(v NAI 12/26/2019 vivint. solar e As PV CIRCUIT(S): .Qq SLOPE-32 SYSTEM LEGEND ® #1)11 MODULES AZIMUTH-259 PV SYSTEM SIZE: MATERIAL- ® #2)10 MODULES COMPOSITION SHINGLE NEW 6.72OkW DC 5.04OkW AC U2 SLOPE-32 EXISTING INTERIOR MAIN SERVICE PANEL d \mN AZIMUTH-79 POINT OF INTERCONNECTION.TIED TO DETACHED MATERIAL- UTILITY METER#15925965. ,COMPOSITION SHINGLE P NEW SMART METER.LOCATED WITHIN 10'OF MSP. V3 SLOPE-32 AZIMUTH-169 NEW PV SYSTEM AC DISCONNECT(RSD). LOCATED MATERIAL- ® WITHIN 10'OF MSP. COMPOSITION SHINGLE C NEW DEDICATED PV SYSTEM COMBINER PANEL. 21 NEW JINKO SOLAR JKM320M-60HBL MODULES NEW ENPHASE ENERGY I07-60-2-US INVERTERS, OO MOUNTED ON THE BACK OF EACH MODULE, 3 O QA N—EW PV_C=ONDUITSEEEE/.O CONDUIT SCHEDULE AMC EXTERIORRUN ATTIC RUN ❑ r------ U -NEW JUNCTION BOX.(MOUNTED TO PVMODULE) NEW JUNCTION BOX.(MOUNTED WTTH SO(ADECKJ EXISTING DETACHED UTILITY METER O #15825965 I ON, I I I I I O O vivint.Solar 1.877.404.4129 319 HAYDENVILLE RD GRUNWALDRESIDENCE 319 HAYDENVILLE RD LEEDS,MA,01053 FRONT OF HOUSE. UTILITY ACCOUNT#:3807267020 SITE PLAN SERVICE 58293709 EGIONAL 2 ROPE ITRA NG CENTER:M401 PV 1.0 DATE:12232019 SCALE;3/16"=Td; DRAWN BY:DIN MOUNTING LEGEND ROCKITCOUPLING MID CLAMP 2 ROCK-IT COUPLING MID CLAMP S1.0 tMID -IT 3.0 COUPLING ROCK-IT ROCK-IT SLIDE CLAMP PEDESTAL METAL ROCKT5116'.318' FIASHINGCOUPLING SHELFHEX FLANGE BOLT 300 SERIES SS ROCK-R COUPLING SHELF ISOMETRIC VIEWCOMP SHINGLES SSLAG SCREWTORQUE=1322 FT-LBSSIDE VIEW x112' TIE PLATE FLANGE BOLT SIDE VIEW 300 SERIES SS 1 ROCK-IT MOUNT DETAIL , 1I �O�SGB 4 GROUNDING LUGS Mn ro s<.NT 51.0 �� sl.o uLusrNcvoRLcaFAsrEK / �m1 \ROCK-IT COUPLING ASSEMBLY nFlcrlr zl e. 51.0 norro�Ali TOP VIEW CLAMP"ATTACHMENT CLAMPS ATTACHMENT COUPLING PERMITTED COUPLBJG CANTILEVER L03 OR LESS CLAMP SPACING ' NDSCAPE=MAX 64'(5'4') PORTRAIT=MAX 48'(4'.0') ROCK-IT SLIDE COUPLING CLAMP RAFTER MODULE MOWLE METAL MODULE FLASHINGA JJEPD..ONDEDWASHER ORMS WATERTIGHT SEAL RAFTER RAFTER RAFTER = iPV SYSTEM MOUNTING DETAIL s MODULES IN PORTRAIT/LANDSCAPE I =PORTMIT 51.0 rat TI Y.N[ 91.0 IgTTo sau CLAMP SPACBJG COMP SHINGLES Z 1 MIN W MIN AND W MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE MIN 5116'DIAM ONE HOLE STEEL STRAP CONDUIT SS LAG SCREW PV MODULE,JYP.MOUNT 1 TORQUE=1322 FT-LBS. TO FRAMING OF EXISTING ROOF TYPE,PARALLEL S 1.0 i v'n iT`. o I a r WITH PLANE OF ROOF CONDUIT MOUNT BRACKET `/ W MAXIMU 1.877.404.4129 Sr C'IUN VIF N 1 1/2' FLASHING OR TILE STRAP GRUNWALD RESIDENCE 319 HAYDENVILLE RD 07-1 LEEDS,MA,01053 SECTION VIEW ^ UTILITY ACCOUNT#:3807267020 s l.o w rosalE / e ,PV ARRAY TYP.ELEVATION CONDUIT MOUNTING DETAIL s l.o osw, s l.o o wKE SERVICE x 54211=REGIONAL -- MOUNT DETAILS CENTER MAS S1 .0 DATE:12!!32019 SCALE:NOT TO SCALE DRAWN BY:DIN � s ti i Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 6720Tag Description Wire Gauge 4of Conductors/Color Conduit Type Conduit Size o AC System Size(Watts) 5040 1 Inverter Output(Enphase QCable) 12 AWG 2(Ll,12) Free Air N/A of o Total Module Count 21 1 EGC(Bare) 6AWG iBARE Free Air N/A ¢ rn 2 Inverter Output(THWN-2) 12 AWG 4(21.1,212) FMC 1/2" to o n 2 EGC(THWN-2) 12 AWG 1(GRN) FMC 1/2" Q 3 Inverter Output(THWN-2) 12AWG 4(21.1,21.2) EMT 112" v > G 3 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" 3 i -oon u u 4 Inverter 0utput(THWN-2) IIOAWG 3(L1,1.2,N)S/R/W JEMT 1/2" '" > � m 4 EGC(THWN-2) 10 AWG 1(GRN) EMT 1/2" _ 5 Service Feeder(THWN-2) 6AWG 3(L1,L2,N)B/R/W EMT 3/4" D 5 IGEC(THWN-2) 18AWG 1(GRN) JEMT 3/4" O of r A d U Gn a 8 a r; PV System SMART Meter g m 0 ¢ to u m Rapid Shutdown Point of Interconnection,Supply Side _> Disconnect,Square D Square D D222NRB 705.12(A) > Z Li DU221RB 24OV/30A W o, '^ Unfused,NEMA3,with 75' 240V/60A 75A Fused,terminNEMA3ations 2 Inverter:Enphase lQ7-60-2-US 15A with 75'C terminations [terminations ¢ Q 10A r~n r~o a 15A z z f ,p Exi sting GE 240W100A SHEET Service Panel,Single NAME: LINE Phase,with SODA Main opIh Disconnect C PVCircuit2:10 1 2 p�m A C 3 Modules/ Parallel = LOAD., 30A M O 9Ic 4 M 4 5 SHEET PV Circuit 1:11 t 2 �m om finer an np se Combiner X-IQ- 4 NUMBER: Modules/ 1 L 1 1 1-240-364 1240V Continuous,protection Parallel — max BOA breaker on solar ouput;with 10 KAIC circuit breakers;Envoy coforms to(12.1-2008 -- ' NEMA4 Junction Box 0 I Visible/Lockable'Knife'AC Visibl lockable'Knife AC Minimum GEC zize6 rt Disconnect Disconnect,In Sight of Tap AWG copper LL; PV Module Rating @ STC Conductor Calculations o SOLAR MODULE Module Make/Model Jinko Solar JKM320M-60HBL o Wire gauge calculated from 310.15(B)(16)&(17)with ambient temperature calculations from v a o Max.Power-Point Current(Imp) 9.59 Amps 310.15(8)(2)(a)&310.15(B)(3)(c)and raceway fill adjustments from 310.15(B)(3)(a).Conduit on m d a n Max.Power-Point Voltage(Vmp) 33.4 Volts - c the roof shall be installed no less than 1"above the roof deck. o „.r Open-Circuit Voltage(Voc) 40.9 Volts "Under Array"conductors use the 90'C ampacity in 310.15(B)(17)with relevant ambient w a Enpnase 107-6o-z-us Short-Circuit Current(Isc) 10.15 Amps temperature adjustments. a > g MICRO-INVERTERAT P I m - u EACH MODULE.ATTACHED Max.Series Fuse(OCPD) 20 Amps PV Circuit conductors use the larger ampacity in 310.15(8)(16)or(17)using the 75'C column with u WITH ECOLIBRIUM SOLAR Nom.Max.Power at STC(Pmax) 320 Watts the continuous duty uprating or the 90'C column with the relevant ambient temperature and s >. HARDWARE TMax.System Voltage 1000 VDC(UL/IEC) raceway fill adjustments and without the continuous duty uprating per 690.8(8). M —_ (A BARE CU GROUND Non-PV Circuit conductors use the ampacity In 310.15(B)(16)in the 75'C column or the 90'C (ATTACHED 70 FIRST MODULE IN Voc Temperature Coefficient -0.28 %/C P tY ARRAY).BALANCE OF ARRAY column with the relevant ambient temperature and raceway fill adjustments,whichever is less GROUNDING CONNECTIONS AC Output Current According to art.690.8(8)(1) 21 Amps (110.14(C)&310.15(A)(2)).The rating of the conductor after adjustments shall be greater than, MADE THROUGH ARRAY g or equal to,the continuous duty uprated current. HARDWARE Nominal AC Voltage 240 Volts THIS PANEL More information about conductor calculations can be provided upon request. IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) MICROINVERTER CONNECTION Calc.Ex:Wire Ampacity x Ambient Temp.Cort.Factor x Conduit Fill Adj.Factor>=Output Current TO ENGAGE TRUNK CABLE (Tag 1 Under Array): Rooftop conductor ampacities designed in compliance with art. Inverter Output:12 AWG rated 30 A, 30 A x 0.96 x 1=28.8 A>=11 A 0 690.8,Tables 310.15(8)(2)(a),310.15(8)(3)(a),310.15(8)(3)(c), (Tag 2 Attic): (A 310.15(B)(16),Chapter 9 Table 4,5,&9. Location specific Inverter Output:12 AWG rated 30 A, 30 A x 0.71 x 0.8=17.04 A>=11 A • temperature obtained from ASHRAE 2017 data tables. (Tag 3 On Roof): Inverter Make/Model Enphase I07-60-2-US ASHRAE 2017-WESTFIELD-BARNES AP Inverter Output:12 AWG rated 20 A, 20 A>=13.75 A m Max.Dc Volt Rating 48 Volts Highest Monthly 2%D.B.Design Temp.:34'C (Tag 4 Exterior): m Max.Power at 40 C 240 Watts Lowest Min.Mean Extreme D.B.:-25.4'C Inverter Output:10 AWG rated 30 A, 30 A>=26.25 A N Nominal AC Voltage 240 Volts (Tag 5 Exterior): Max.AC Current 1 Amps Service Feeder:6 AWG rated 65 A, 65 A>=60 A Max.OCPD Rating 20 Amps u Max.Panels/Circuit 16 Short Circuit Current 15 Amps m N OCPD Calculations Breakers sized according to continuous duty output current.PV circuit nominal current based off# g of modules per Circuit X(1.25[art.690.8(A)])X(1 Max AC current per micro-inverter) O .+ Circuit#1=11 modules,Output Current w/continuous duty=13.75<=15A Breaker w Circuit#2=10 modules,Output Current w/continuous duty=12.5<=15A Breaker system output current w/continuous duty=26.25<=30A(System OCPD) > z ui J J J M M Other Notes z z •Designed according to and all code citations are relevant to the 2017 National Electrical Code. SHEET •All interior raceways carrying Dc current shall be metallic. NAME: N Y d 2 6 SHEET NUMBER: N W R DocuSign Envelope ID: 16EEOC6F-F286-4C11-9FD4-9EOF11FE119A vivint.Solar Residential Solar Energy System Lease Agreement Customer Name&Contact Information: Installation Location: Name(s): Janet Grunwal d Address: 319 Haydenvi l l e Rd Contract co-signer Leeds MA 01053 Email: flamingos7@comcast. net Approx.Installation Start and Completion Date: 6/11/2020 Primary Phone: 4133201170 Account No.: 5-6283309 Date of Customer Signature: December 14, 2019 1 9:59 AM MST so See Exhibit A 2 Oyr Up-Front Cost Monthly Payment Initial Term Our Promises • We will design,install,operate and maintain a solar energy system on your home(the"System"). • We warranty all of our work,and that our roof penetrations will be watertight,for 20 years. • We will fix or pay for any damage we may cause to your Property or belongings. • We guarantee that the System will produce a certain amount of energy. • We will not place a lien on your Property,but will record a notice of our ownership of the System. • You will not be responsible for any personal property taxes assessed on the System. • The Monthly Payment includes a$5 monthly discount for paying by automatic debit from your bank account. • If you need to make Property repairs,we will remove and reinstall the System if you pay our estimated costs. At the End of Your Initial Term If You Move • You can renew the Agreement for a subsequent term; • You can transfer the Agreement to the new homeowner, • You can purchase the System;or regardless of credit rating; • You can request that we remove the System at no • You can prepay the Agreement; additional cost. • After the sixth anniversary,you can purchase the System;or • You can relocate the System under certain circumstances. Your Commitment • Pay the Monthly Payment to lease the System. • Keep your roof in good condition throughout the Initial Term. • Respond to our sales and support teams when scheduling work and completing paperwork. • Maintain a broadband internet connection. • Continue service with your utility for any energy used beyond the System's production. You may cancel this Agreement any time prior to commencement of any work at or near your Property associated with installation of the System. Vivint Solar Developer, LLC (EIN: 80-0756438) is a licensed contractor in each state in which we operate, including Massachusetts, license numbers HIC-170848 and EC.15688A. For more information, see Exhibit C and visit www.vivintsolar.com/licenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN & OPT-OUT NOTICE BELOW IN SECTION 25 OF THE GENERAL PROVISIONS FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: 1800 W Ashton Blvd., Lehi, UT 84043 help@vivintsolar.com I vivintsolancom ATTN: Processing Department Phone 877.404.4129 1 Fax 801.765.5758 Copyright© 2019 Vivint Solar Developer, LLC. All Rights Reserved. Lease(5/2019, v4.0.2) Page 1 of 16 Docu Sign Envelope ID: 16EEOC6F-F286-4C11-9FD4-9EOF11FE119A SIGNATURE PAGE AND NOTICE TO CUSTOMEK A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT. These documents are incorporated into this Agreement and apply to the relationship between you and us: (1) Lease Agreement, (2) General Provisions, (3) Customer Packet; and (4) any attachments, disclosures and exhibits, as applicable. x❑ BY CHECKING THIS BOX, YOU ACKNOWLEDGE RECEIPT OF EXHIBIT A— LEASE DISCLOSURES, AGREE TO MAKE PAYMENT AS SET FORTH IN EXHIBIT A, AND AGREE THIS CHECKBOX CONSTITUTES YOUR ELECTRONIC SIGNATURE. B. WE HAVE NOT GUARANTEED, PROMISED OR OTHERWISE REPRESENTED ANY REDUCTION IN ELECTRICITY COSTS IN RELATION TO THE SYSTEM THAT WILL BE INSTALLED ON YOUR PROPERTY. C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS AGREEMENT. D. IF YOU DO NOT ELECT ANY OF THE END-OF-TERM OPTIONS SET FORTH IN SECTION 2(A), THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS. CONSULT SECTION 2 FOR MORE INFORMATION. E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO A SALES REPRESENTATIVE. F. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement, signed by both you and us, before any work may be started. G. YOU, THE CUSTOMER, MAY CANCEL THIS CONTRACT AT ANY TIME BEFORE MIDNIGHT OF THE THIRD (3RD) BUSINESS DAY AFTER THE TRANSACTION DATE. SEE THE ATTACHED NOTICE OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. DO NOT SIGN BELOW UNLESS WE HAVE GIVEN YOU THE "NOTICE OF CANCELLATION". REPRESENTATIVE: DocuSlgnedby: CUSTOMER(S): DoauSigned by: r Signature: ", i�1 Signature: v Printed Name: Sabrina Doppman Printed Name: 3anet Grunwald 215985 December 14, 2019 1 9:59 AM MST Salesperson No.: Date: Date: December 14, 2019 1 9:59 AM MST Signature: FOR OFFICE USE ONLY Printed Name: THIS AGREEMENT IS NOT EFFECTIVE NOR BINDING UPON VIVINT SOLAR DEVELOPER, LLC UNTIL SIGNED Date: BY AN AUTHORIZED REPRESENTATIVE. VIVINT SOLAR DEVELOPER, LLC I Signature: ►'//G44,04, gA44,14 Printed Name: Madison Barnes Date: 12/14/2019 Processing No.: 215546 ' Copyright©2019 Vivint Solar Developer, LLC. All Rights Reserved. LEASE(5/2019, v4.0.2) Page 16 of 16