Loading...
36-284 (13) Type , The Commonwealth of Massachusetts A F City of Northampton , ; Certi icate of Occupancy In accordance with 780 CMR, (The 9th Edition of the Massachusetts State Building Code) this Certificate of Occupancy is issued to the premise or structure or part thereof as herein identified. Identify Name of Building of Space Within Certificate No. Issued to BP-2020-0392 Gandara Center Identify property address including street number, name, city or town and county Located at 610 Burts Pit Road Sprinkler System in Northampton, Hampshire, Massachusetts accordance with NFPA 13D Use Group Classification(s) Residential Group R-3 This Certificate of Occupancy is hereby issued by the undersigned to certify that the premise,structure or portion thereof as herein specified has been inspected for general fire and life safety features. This certificate shall allow for the use as herein described and in conformance with any and all conditions as identified below. It shall be posted in a conspicuous place within the space as directed by the undersigned. Failure to post the certificate,failure to comply with conditions or, tampering with the contents of the certificate is strictly prohibited. Conditions of Use Structural,Means of Egress and Life Safety systems must be maintained. LNameofnicipal Date of Final Map/Plot: cialKevin Ross Inspection 01/06/2020 Municipal Date of36-284 cial ////Z Issuance 01/07/2020 Commonwealth OfMassachusetts City of Northampton Map: Block: Lot: 36 284 001 in Accordance With The Massachusetts State Building Code, Section 110, This CERTIFICATE OF INSPECTION is issued to Gandara Mental Health Center, Inc. 1 Certifythat I have Inspected the R3 known as Pride House located at 610 BURTS PIT RD, BP in the City of Northampton The Means Of Egress Are Sufficient For The Following Number Of Persons: BY STORY Story Capacity Story Capacity BY PLACE OF ASSEMBLY OR STRUCTURE Place of Assembly or Structure Capacity Location Place of Assembly or Structure Capacity Location 12 CI-2020-0012 01/07/2020 01/07/2021 Certificate Number Date Certificate Issued Date Certificate Expires Building Official **.4 COPY OF THIS CER TIFICA TE MUST BE POSTED IN CLEAR VIE w NEAR ALL ENTRANCES 212 Main Street-Rm 100*NORTHAMPTON,MA*Phone:(413)587-1240*Fax:(413)587-1272 610 BURTS PIT RD BP-2020-0631 GIS 4: COMMONWEALTH OF MASSACHUSETTS Map:Block: 36-284 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: BASEMENT RENOVATION BUILDING PERMIT Permit# BP-2020-0631 Project# JS-2020-000406 Est. Cost: $5800.00 Fee: $100.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contrtictor: License: Use Group: FITZGERALD BURGLARY_ Lot Size(sq. ft.): 33454.08 Owner: GANDARA MENTAL HEALTH Zoning: pNicant: FITZGERALD BURGLARY AT: 610 BURTS PIT RD Applicant Address: Phone: Insurance: 50 GERRARD AVE (413) 537-3644 EAST LONGMEADOWMA01028 ISSUED ON.1111412019 0:00:00 TO PERFORM THE FOLLOWING WORK:UPDATE FIRE & SECURITY SYSTEMS AND INSTALL CAMERA SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Finally/*-1 -//? owl Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS�ULES AND RE 'ULATIONS. Certificate of Signature: FeeType: Date Paid: Amount: Building 11/14/20190:00:00 $100.00 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck--Building Commissioner 0 - ii F I T Z GE R.ALD BURGLARY 50 Gerrard Ave. East Longmeadow Ma. 01028 413-733-5529 Fire alarm inspection and test report Customer Gandara Northampton Address 610 Burts Pit Road Date of inspection 11/27/2019 Inspector: Fitzgerald Burglary # 820C/21521) MICHAEL FITZGERALD Location phone number Owner/Representative: Joe Martins Fire Department: Northampton Panel location: Basement Panel model: E-FSP System type: Remote Signaling Signals received: CMS 1-800-432-1429 Remote Annunciator: Kitchen /Front Hall Smoke detector type: Style Y Class B Zone type: Class B Zones: 4 Main Power: AC Breaker Disconnect Location: Basement Auxiliary Power: 24VDC Condition: Good Battery Voltage: Before Drain Test: 25.5 After Drain Test: 24.9 r , Location: Device # Device Result Basement bottom of stairs rear 1 Smoke P Basement bottom of stairs front 2 Smoke P 1st floor hallway rear 3 Smoke P I" floor front stairwell 4 Smoke P 1St floor right office 5 Smoke P 1st floor left office 6 Smoke P 1st floor rear stairwell 7 Smoke P 2"d floor front right room 8 Smoke P 2"d floor rear right room 9 Smoke P 2"d floor front stairwell 10 Smoke P 2"d floor rear stairwell 11 Smoke P 2"d floor walk in closet 12 Heat N/A 2"d floor laundry 13 Heat N/A 1st floor living room /kitchen area 20 Smoke P Basement H1 Horn/Strobe P 1" floor H2 Horn/Strobe P 2"d floor H3 Horn/Strobe P Comments: All fire alarm Components tested in accordance with NFPA - 72. No deficiencies found. DATE 11/27/19 TECHNICIAN SIGNATURE Wichaef] Titzgerafd r � Northampton Fire Rescue Occupancy: Lisa Perrot ' Occupancy ID: FLR1223 Address: 610 Burts Pit RD Florence MA 01062 Inspection Type: Alarm System Test Inspection Date: 11/27/2019 By: Pelis, Andrew S (F3274) Form: Residential Smoke & Time In: 10:52 Time Out: 10:52 CO Authorized Date: 11/27/2019 By: Pelis, Andrew S (F3274) Inspection Description: MGL C. 148 s. 26F. All buildings or structures occupied in whole or in part for residential purposes shall, upon the sale or transfer of such building or structure, be equipped by the seller with approved smoke detectors. s. 26F1/2 Every dwelling, building or structure, occupied in whole or in part for residential purposes, shall, upon sale or transfer o such dwelling, building or structure, shall be equipped by the owner with working, approved carbon monoxide alarms. 527 CMR 1.00 Section 13.7 Inspection Topics: Inspection Residence meets the 26F and/or 26F1/2 requirements? Does the residence meet the 26F and/or 26F1/2 requirements? Status: Notes: Fee Fee Paid $50-Single Family$100-Two Family$150-3-6 Units$500-7+Units Status: Notes: Re-inspection $20-Re-inspection Status: Notes: Additional Time Spent on Inspection: Category Start Date I Time End Date/Time Notes: No Additional time recorded Total Additional Time: 0 minutes Inspection Time: 0 minutes Total Time: 0 minutes Summary: Overall Result: Passed Inspector Notes: Conducted alarm test. Installed new radio box. System reported and was working. Printed on 12/27/19 at 10:20:16 Page 1 of 2 Closing Notes: Smoke and Carbon Monoxide inspections are valid for 60 days from date of inspection. Inspector: Name: Pelis, Andrew S Rank: Captain Pelis, Andrew S: Signed on: 11/27/2019 10:53 Signature Date Representative Signature: Signature Date Printed on 12/27/19 at 10:20:16 Page 2 of 2 Northampton Fire Rescue Occupancy: Lisa Perrot Occupancy ID: FLR1223 Address: 610 Burts Pit RD Florence MA 01062 Inspection Type: Sprinkler Test Inspection Date: 12/27/2019 By: Davine, Jon (F3347) Form: Residential Smoke & Time In: 08:33 Time Out: 08:33 CO Authorized Date: Not Author By: Insection Description: MGL C. 148 s. 26F. All buildings or structures occupied in whole or in part for residential purposes shall, upon the sale or transfer of such building or structure, be equipped by the seller with approved smoke detectors. s. 26F1/2 Every dwelling, building or structure, occupied in whole or in part for residential purposes, shall, upon sale or transfer o such dwelling, building or structure, shall be equipped by the owner with working, approved carbon monoxide alarms. 527 CMR 1.00 Section 13.7 Inspection Topics: Inspection Residence meets the 26F and/or 26F1/2 requirements? Does the residence meet the 26F and/or 26F1/2 requirements? Status: Notes: Fee Fee Paid $50-Single Family$100-Two Family$150-3-6 Units$500-7+Units Status: Notes: Re-inspection $20-Re-inspection Status: Notes: Additional Time Spent on Inspection: Category Start Date / Time End Date / Time Notes: No Additional time recorded Total Additional Time: 0 minutes Inspection Time: 0 minutes Total Time: 0 minutes Summary: Overall Result: Passed Inspector Notes: Tested the sprinkler system and it activated the alarm in 15 seconds and successfully contacted the alarm company. Printed on 12/27/19 at 10:19:05 Page 1 of 2 Closing Notes: Smoke and Carbon Monoxide inspections are valid for 60 days from date of inspection. Inspector: Name: Davine, Jon Rank: Assistant Chief Davine, Jon: Signed on: 12/27/2019 10:18 Signature Date Representative Signature Signature Date Printed on 12/27/19 at 10:19:05 Page 2 of 2