Loading...
22B-025 (5) 25 CORTICELLI ST BP-2020-0733 cls#: COMMONWEALTH OF MASSACHUSETTS Map:Block:22B-025 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2020-0733 Proiect# JS-2020-001257 Est.Cost: $27359.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VALLEY SOLAR LLC 077279 Lot Size(sg.ft.): 11064.24 Owner: AIKEN CHRISTOPHER Zoning: URB(100)/ Applicant. VALLEY SOLAR LLC AT: 25 CORTICELLI ST Applicant Address: Phone: Lisurance: PO BOX 60627 (413) 584-8844 WC FLORENCEMA01062 ISSUED ON.1211312019 0:00:00 TO PERFORM THE FOLLOWING WORK.-25 PANEL SOLAR ARRAY - 8.71 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 12/13/2019 0:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner o ar Department use only City of Northampton F? gtatus of Permit: <t '% Building Depart�men uUlr eway Permit 212 Main Steeet Se /Sep c Availability ROOM 10,0 DEC ,3 X01 wat r/Wel Availability Northampton, MAO 060 Tw Sets f Structural Plans --'' phone 413-587-1240 Fax 4f3F -rr Plo Site tans at4p r�N'�Jsppcer S cify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR H A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: Map �d � Lot (JUnit 25 Corticelli St Florence, MA 01062 Zone Overlay District Elm St.District CB District SECTION 2 -PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Chris Aiken 25 Corticelli St Florence, MA 01062 Name(Print) Current Mailing Address: 610-425-7672 Telephone Signature 2.2 Authorized Agent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) Current Mailing Address: '&w-M GL_ �i ev��rnan 413-584-8844 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total= (1 + 2 + 3+4 + 5) 1:5( Check Number p1 This Section For Official Use Only � Date Building Permit Number: y 7a) 2 Issued: Signature: I`� -31 Building Commissioner/Inspector of Buildings Date Ihasbrouck @ northamptonma.gov info( valleysolar.solar EMAIL ADDRESS (REQUIRED; CONTRACTOR) SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding [[3] Other[X Solar Brief Description of Proposed Work: Installation of a 26 Panel solar roof mount array. System size 8.71 kW DC. Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Chris Aiken as Owner of the subject property hereby authorize Valley Solar LLC to act on my behalf, in all matters relative to work authorized by this building permit application. if a n 12/13/2019 Signature of Date Valley Solar LLC as Gwaec/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Steven Silverman Print Name ,&vm 0, ��ev e�to a n 12/12/2019 Signature of Owner/Agent Date SECTION 8 -CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder: Steven Silverman License Number PO BOX 60627, Florence, MA 01062 CS-077279 Address Expiration Date ,�tz,v-M 0- 6/21/2020 Signature Telephone 413-584-8844 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 10/27/20 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152, §25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... No...... ❑ City of Northampton -}' Massachusetts DEPARTMENT OF BUILDING INSPECTIONS A r 212 Main Street •Municipal Building Northampton, MA 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: �1� Dov ik c-.r ST (Please print house number and street name) Is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Address) I1 Signature of Permit Wicant or Owner If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. The Conunonivealth of Massachusetts w Department of•Industrial Accidents r ;. Office of Investigations 600 Washington Street r Boston, MA 02111 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers ADMicant Information Please Print Legibly Name(flusitess/orgartizttiott/individual); Valley Solar LLC Address:340 Riverside Drive PO BOX 60627 City/State/zip:Florence, MA 01062 Phone It: 413-584-8844 Are you an employer?Checkthe appropriate box: Type of project(required): 1.® I am a employer with I 1 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors �' E] New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have S. ❑ Demolition working for me in any capacity. employees and have workers' INo workers' comp. insurance comp. insurance.+ ❑ Building addition required.] 5. [] We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I I.❑ Plumbing repairs or additions myself. INo workers'comp. right ofexemption per MGI. 12 ❑ Roof repairs insurance required.1 t c. 1.52, §1(4). and we have no employers. I No workers' 13.M Other Solar comp. insurance required.] *Any applicant that checks hux NI must alSO till out the action Ielow shox+inp,their%%orkerc'compensation Ix)[icy inibnnalion. i Lloneowners w9to they submit this atlidavit indicating thare doing all work and then hire outside contrarams must,nbmit a new allidavit indicating such. C'ontructom that check this Nix must attached an additional sheet showing the name oi'the sub-contractors and state whether or not thou entities have employees. if the suh-contractors hacc employees,they must provide their %%orkers'comp.polic% number. /ane an employer ticat is providing►w�rkerc'compeccsation irisrrrance for ncy encployec�c. Below is Lice polio and joh site infortnation. Insurance Company Name:_Llherh/ Mutual Policy#or Self-ins. Lie.#:WC5311 S620647019 Expiration nate: 2/1/2020 Job Site Address: T5 eoullaw ST City/State/Zip: ,FL MA 2 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGI.c. 152 can lead to the imposition orcriminal penalties ora tine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form ofa STOP WORK ORDER and a line of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do herehp certify under cq pants and penalfies of perj r+ i lite hilorm ation provided above is trite and correct Si*nature: - LA - -- Date: 12— -9" - Phone#: 413-584-8844 Official use on&. Do not write in this area,to he co►npleted hh c•ity or town official. City or Town: Permit/License 4 Issuing Authority(circle one): 1. Board or Health 2. Building Department 3. City/Towu Clerk 4. Electrical luspectur M. Plnnalaing Ill, fur 6. Other Contact Person: Phone#; *PennFUSION 1 52 S. Broad E n y l fl • • f 1 n 9 Lansdale, PA 1944466 (215)361-8040 June 13, 2019 Valley Solar 340 Riverside Dr Northampton, MA 01062 RE: Aiken Residence 25 Corticelli St,Florence, MA 01062 Client Project#:25AIKE PFE Project#: 193184 On behalf of Valley Solar, Penn Fusion Engineering LLC (PFE) performed a structural analysis of the roof at the above referenced location.The purpose of our analysis was to determine if the existing roof system is structurally sufficient to support the new photovoltaic moudles in addition to the code required design loads.Our analysis is based on the information provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed. System Specifications: Total System Size: 8.71 kW/DC Panel Specs: (26) LG Solar- LG335N 1 C-A5 Inverter Specs: (26) Enphase- IQ7 Racking System: SnapNRack-Series 100 UL The modules are to be located on the following roof planes: Mounting Rafter Rafter Horizontal Collar Collar Tie Shingle Number of Ceiling Plane Size Spacing Span Ties Spacing Sheathing Type Shingle Layers Profile 1 Truss 24" 1 6ft. Oin. N/A 0" CDX 1/2" Shingles 1 Flat 2 2x8 16" 1 3ft. Oin. N/A W CDX 112" Asphalt 1 Flat Shingles The roof design has been analyzed in accordance with the 2015 International Residential Code and Massachusettes Amendments 9th Edition with design loads as follows: Ground Snow(Pg): 40 psf Wind Speed (V): 1 1 7 mph Mounting Plane 1 It has been g that jspwfied,abawk ist ` q twl+Y 1 [fit Attach the module rail brackets to the roof with 5/16"lag bolts at 48 on center maximum with staggered penetration such that load is distributed evenly among roof members. Provide a minimum of 2" of penetration into the wood members. Mounting Plane 2 „fit k��.exermined by this office that .::is Attach the module rail brackets to the roof with 5/16"lag bolts at 48 on center maximum with staggered penetration such that load is distributed evenly among roof members. Provide a minimum of 2" of penetration into the wood members. This office has determined that the installation of the PV System as specified above will meet the structural requirements of the 2015 International Residential Code with Massachusettes Amendments 9th Edition and ASCE?-10 when installed in accordance with the manufacture's instructions. If you have any questions regarding this analysis, please feel free to contact us. t."OF 114,s9 Best Regards, �,� oy Penn Fusion Engineering LLC o G A^FtEW DOMEY C R, `j LEO%E NO 5304.%_ Andrew D. Leone, P.E. Principal <U�U s C LL Y r z • V O V by Pit x n a m r40 R .r W m 41A A go,4 adddo SYSTEM BRIEF PROJECT COMPONENTS a aInstallation of a 8.71kWD,6.24kWAC, BACKYARD SHED 26 LG335N1C-V5 SOLAR PV PANELS N a 26 panel roof mount solar array on ® ( ) ( ) � the back yard shed. (26)ENPHASE IQ7-60-2-US MICROINVERTERS x" SNAPNRACK ULTRA RAIL RACKING(N) =e o E�ao Array attached using Ecofasten Solar ENPHASE COMBINER X IQ-AM1-240 3(N) ato CorruSlide Corrugated roof bracket SUB PANEL(E) ?e g on Fabral Grand Rib3 metal roofing. BASEMENT Conductors will be pulled through 1 AC DISCONNECT(N) J m g s° E PANEL( ) oa �g existing conduit to basement of MAIN SERVICE P a house out to meters on street.Point >` of interconnection at main service EXTERIOR WALL OF HOUSE -- panel. © MA SMART GENERATION METER(N) _ = o c r =64 e AC DISCONNECT(N) _ -- -- - - -- ; UTILITY METER(E) �j� -�- --; vj• �- ^. pep:- a—z: e ►� Utility Client:CHRIS AIKEN,25 CORTICELLI ST.,FLORENCE MA 01062 N t F J 37 s CORTICELLI v ST � � • r L— a o 25 CORTICELLI ST Y s U NORTHAMPTON ��� US8^ m - 2219o m CORTICELLI C::ne AlKEN CHRIS & ANGIE HAUSER N v N ST 25 CORTICELi_! ST tZ FLORENCE f01A 01062 , Euiiding Value: $173,000 N 25 Land Value $130.400 CORTICELLI ,,.•� . her Vaiue s0 F- LI ' ST .f-`" Tota! Value: $303.400 a ►, -'`` 10 PARK 19 ;essment data from FY 2014 ST 21 CORTICEL Z o � COWICELLI ST Lot Size. 0.25 Acres ST Last Sate Price'. $315.000 g a Last Sale Date: 20120524 ` 1 Use Code 101 10a. LI Year Built: 1900 T _'corn to 17 �. CORTICELLI 0 30 60ft 5T �s 20 Inverter Trio Settings: Labeling Schedule Eauinment Schedule (�) g Inverter TRIP settings are set in the inverter per the ISO NE SRD and ESB 756 section 7.6.11. 1 WARNING!PHOTOVOLTAIC POWER SOURCE 1 RACKING(Ultra-Rail)Snap N Rack Roof Mount System ?1 DEVICE DEFAULT DEFAULT Pickups and 2 SOLAR PV AC COMBINER BOX 2 MODULE 26x LG335N1 C-V5 panels.Max output 41.OV/ SPICKUP ETTING CLEARING TIME ClearingTimss 3 RAPID SHUTDOWN SHUTDOWN SWITCH FOR 10.49A C it (seconds) Adhere to SOLAR SYSTEM(reflective) 31 MICROINVERTER 26x Enphase IQ7-60-2-US.Max (simplified Required 4 PV SYSTEM AC DISCONNECT Rated AC Output output 240VA/1.0A defaults from Defaults(Yes/ Current:26.OAAC Nominal Operating Voltage:240V 4 AC COMBINER(X-IQ-AMI-240-2)2x 20A Breaker/ section 7.6.11) No): AC branch. 1 x I OA breaker for IQ Envoy Gateway with Under Frequency 56.5 Hz 0.16 Yes 5.WARNING!ELECTRICAL SHOCK HAZARD production CTs(exterior of shed) t (61u) TERMINALS ON BOTH LINE AND LOAD SIDES MAY 5 AC DISCONNECT(DG222URB)60A 240VAC(adjacent - Under Frequency 56.5 Hz 30o Yes BE ENERGIZED IN THE OPEN POSITION to utility meter) <o (81 U) 6.UTILITY GENERATION METER fi GENERATION METER(U5934)Milbank meter socket Over Frequency 1 61.2 Hz 300 Yes7.WARNING BUSBAR IS ENERGIZED FROM 2 for Utility owned SMART Generation meter 0 N 3 y (e1o► SOURCES UTILITY GRID AND PHOTOVOLTAIC Z MAIN SERVICE PANEL 200A MAIN,200A BUS.35A 5 m Over Frequency 62.0 Hz 0.16 Yes SYSTEM system OCPD. (610) &WARNING!INVERTER OUTPUT CONNECTION DO $UTILITY METER(71056617)120/24OV, 1PH,3W w § Under Voltage 50%of Nominal 1.1 Yes w¢ m NOT RELOCATE THIS OVERCURRENT DEVICE o a F Under Voltage 88%of Nominal 2 yes9.SOLAR PV 0) (27) 10. WARNING!UTILITY METER ENERGIZED BY 2 t: > v w m Over Voltage(59) 0%of Nominal 2 Yes SOURCES 11. UTILITY SERVICE METER Over Voltage(59) 120%ofNominal 0.16 Yes Conductor/OCPDCalculations: aga NEC 210.19(A)(1)(a))Inverter Max Output=1.0A a x 26=26.OA x 1.25=32.5A — MOD 12 MOO MOD MOD 1 � J U MICRO 2 1 LINE on the tap and INVERTERS VCJ.# the LOAD on the U @ I CIRCCUITH CH 4 2 3 bottom side of the MA J 3 SMART eterW AC_ AC AC AC AC Combiner Box l e DC DC DC DC 3 Main i g 3 eox 5 4 5 b b Service 8` 10 11 s Panel o g MOD MOO MOD MOD n Ac Disco �F � kW �A —!Z M M TO/FROM $ ® MICRO (2)1212 Rx o 3 INVERTERS (1,a6 GUEGC UTILITY �m IN BRANCH '✓ a u w�+ CIRCUIT NI (3),#6 THHN (4)CBTHHN 613 SER 35A 4/0 SE h 'a AC AC AC AC ma]UGTION cr• (1)p6 cU EGC 1.s•aft.,n PdN a DC . . . . . . . . . DC DC DC - IN1.6'PVC uE` > Isolation Deice between -I (1)#6 CU THHN (2)02 CUTHWN-2. Company meter and DER AC Isolation Device SMART Meter AC Isolation Device EGC Q Cahle P Y I..il U ik THIS ELECTRICAL DRAWING 15 A PROPOSED DESIGN,THE ELECTRICIAN IS AT LIBERTY TO ADJUST DURING THE BUILD AND AMENDMENTS WILL BE REELECTED IN THE AS-BUILT DIAGRAM. Y LG335N 1 C-V5 335W The LG NeONO 2 is LG's best selling solar module,and is one of the most powerful and versatile modules on the market today.Featuring LG's Cello Technology, the LG NeON® 2 increases power output. New updates include an extended performance warranty from 86% to 89.6% to give customers higher performance and reliability. p C C r���yyy\\\eee''\wmuwaawa+a C �{�U� UJ N progress Made in USAF Fro.!.ported Parts Features Enhanced Performance Warranty Enhanced Product Warranty LG NeON® 2 has an enhanced performance LG has extended the warranty of the NeON®2 warranty. After 25 years,LG NeONe 2 is guar- to 25 years,which is among the top of industry anteed to perform at minimum 89.6%of initial standards. performance. Better Performance on a Sunny Day 4 Roof Aesthetics LG NeON®2 now performs better on sunny LG NeON® 2 has been designed with aesthetics in days,thanks to its improved temperature mind using thinner wires that appear all black at a coefficient. distance. The LG NeON®2 can increase the aesthetic value of your home with a more modern design. About LG Electronics LG Ei.o n s is a global leader in electren,,pmductc in the clean energy markets by ntfeang xMar Pt1 panelsanA energy omrxge systems The company fiat emar bked LG on a solar energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoXe series to the market,which is now available in 32 countries.The NcON's(previous.MonoXs NoON),Ne0Ne2,NeONe2 SiPacial won the"Imersolar AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation m the solar industry. LG r emi� No 2rted Parrs� LG335N1C-V5 General Data Electrical Properties(STC*) Cell Properties(Material/Type) Monocrystalline/N-type Madel L633SNTC-VS Cell Maker LG Maximum Power(Pmax) [W] 335 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) [V] 34.1 Number of Busbars 12EA MPP Current(Impp) [A] 9.83 Module Dimensions(L x W x H) 1,686mm x 1,016mm x 40 mm Open Circuit Voltage(VoS t s%) [V] 41.0 Weight -- 17.1 kg _ - ShortCircuit Current(kc,2%) [A] 10.49 Glass(Matenal) Tempered Glass with AR Coating Module Efficiency [%) 19.6 _. --._.. .. [%] -r3 Backsheet(Color) .White powerTok:rance 0 ___._..___.-____-_-.._._._�..._._�____��____.-__..___ I'mme(Matenal) Anodized Aluminium 'STC(Standard Test Condition).Irradiance 1000 W/m',Cell temperature 2S°C,AM is Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes Cables(Length) 1,000 mm x 2EA Operating Conditions ConnectoKType/Maker) MC 4/MC Operating Temperature [•C'; -40-+90 Maximum System Voltage [V] 1,000(UL),1000(IEC) Maximum Series Fuse Rating [A i 20 Certifications and Warranty Mechanical Test load(Front) Pa!psf; 5,400/113 IEC 61215-1/-1.1/22016,IEC 61730- Mechanical Test -_(Pa 1psf]_ 4,000/84 1/2:201 6,UL 1703 'Test loan-Design load X Safety Factor(1.5) Certifications ISO 9001,ISO 14001,ISO 50001 Packaging Configuration OHSAS 18001,PV CYCLE ----_--_-- Number of Modules per Pallet [EA] 25 Salt Mist Corrosion Test IEC 61701:2012 Seventy 6 Number of Modules per 40ft HQ Container [EA] 650 Ammonia Corrosion Test IEC 62716:2013 Packaging Box Dimensions(L x W x H) [mm] 1,750 x 1,120 x 1,221 Module Fire Performance Type 1(UL 1703) Packaging Box Gross Weight [kg] 454 Fire Rating Class C(UL790,ULC/ORD C 1703) Solar Module Product Warranty 25 Years Solar Module Output Warranty linear Warranty Dimensions(mm 1 inch) •1 First year:98%2)After 1 st year:035%annual degradation 3)89.6%fa 25 years Temperature Characteristics NMOT [ •C]_�- 42:1:3 A Pm" Nrc] -036. Voc Nrcl -0.27 — kc: [%rc] 0.03 u•. b.i a-ro 0-4 (u.r:•wvd,l -.. �.. •NMOT(Nominal Module Operating Temperature):Inachance 800 W/m,Ambient temperature 20'C, -- Wind speed i m/s,Spectrum AM I.S Electrical Properties T� rties NMO � Model LG33SN1C-Vs Maximum Power(Pmax) [W) 250 MPP Voltage(Vmpp) [Vj 31.9 MPP Current(Impp) I_Al _ - 7.84 -. Open Circuit Voltage(Voc) [V] 38.5 Short Circuit Current(Isc) - 8.43 r i 1-V Curves 100ow e r, eoow c 6.0 v 400w n` zaow ` - --— voltage(VI ® LG LG Electronics Inc Product specifications are subject to change without nonce ❑■ Solar Business Division LG335N1C-VS US Ver01 2000 Millbrook Drive . Lincolnshire,IL 60069 ®2019 LG Electronics.Alt rights reserved. Life's Good ■ +� www.lg-solarcom Enphase The high-powered smart grid-ready Enphase IQ 7 Micro' and Fnphase IQ 7+ Micro" IQ 7 and IQ 7+ dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple i Faster installation with improved,lighter two wire cabling Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable -- Optimized for high powered 60-cell and 72-cell*modules More than a million hours of testing Class II double-insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) u 'The IQ 7+Micro is required to support 72-cell modules. L To learn more about Enphase offerings,visit enphase.com � ENPHASE. s E. : Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) I07-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235W-350W+ 2.35 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27V-37V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22V/48V 22V/60V Max DC short circuit current(module Isc) 15A 15A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range' 240 V/ 208V/ 240 V/ 208 V/ 211-264 V 183-229V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V x@208 V Peak efficiency 97.6% 97.6% 97.5°i 97.3°i CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4°i to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httns://enohase com/en-u$/support/module-comp ti i Lty. 2.Norninal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of rnicroinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com U EN PHASE. C?2019 Enphase Energy All rights reserved.All trademarks or brands used are the property or Enphase Energy,Inc. 2019-3-26 SNAPNRACK UR-40 RAIL SHOWN SPLICED REVISION: TOGETHER WITH THE SNAPNRACK ULTRA g 110/2017 NEW DETAIL MA RAIL SPLICE. 2"MAX %"-'/"RAIL GAP - 2"MIN FOR THERMAL EXPANSION _ TORQUE SPECIFICATIONS: AT SPLICES 5/16"O NUTS&BOLTS,10-16 FT-LBS - CENTER SPLICE BETWEEN THE TWO BONDING CLIPS AS SHOWN IN"SPLICE ALIGNMENT LIMITS"VIEW nom,. RAIL EDGE MUST NOT PASS- SPLICE ALIGNMENT LIMITS THE CLIP EDGE,AS SHOWN. SNAPNRACK UR-40 RAIL, TYR SNAPNRACK BONDING CLIP,TYPE 2 8 FOR BONDING ACROSS RAILS 5116"o-18 BOLT,S.S. SNAPNRACK ULTRA SPLICE ASSEMBLY, CENTER ON RAIL GAP t 1" SNAPNRACK ULTRA SNAPNRACK ULTRA SPLICE,THRU SPLICE,TAPPED ^ w Surxun South LLC DESIGNER: M.Affentranger SCALE: PART NUMBER: DESCRIPTION: REV �r(��f' �l� ��."��,.2o<"a�.A���"C.w,"s"sA DNS n Nkrmm_ el "neNAsmsao.vw,iAswem DRAFTER: M.Affentranaer UR40-D05 UR-40 ULTRA SPLICE DETAILS DATE: 11/7/2017 APPROVED BY: G.McPheeters SNAPNRACK UR-40 RACKING SYSTEM REVISION: SHOWN MOUNTED ON ULTRA FOOT WITH SNAPNRACK g 11/30/2017 NEW DETAIL MA UNIVERSAL END CLAMPS.FOR TILE MID CLAMP, — ROOFING USE SNAPNRACK TILE "RAIL END OVERHANG" TMP' REPLACEMENT,UNIVERSAL TILE HOOK,OR NOT TO EXCEED 34%OF — — FLAT TILE HOOK SYSTEMS. ACCEPTABLE RAIL SPAN = STANDARD LAG SCREW SPEC ASSUMES SNAPNRACK UNIVERSAL END CLAMP ASSEMBLY,TYP. y 5/16"0 LAG SCREW WITH 21%"MIN. / EMBEDMENT INTO STRUCTURAL MEMBER. TOROUE SPECIFICATIONS: ® SNAPNRACK ROOF ATTACHMENT 5/16"0 NUTS&BOLTS,10-16 FT-LBS SNAPNRACK UR-40 RAIL,TYP. (MODULE HIDDEN FOR CLARITY) RAILS CAN BE MOUNTED ON EITHER SIDE OF ULTRA FOOT;UPSLOPE OR DOWNSLOPE. DETAIL A FOR UNEVEN ROOF SURFACES,UTILIZE THE SNAPNRACK LEVELER.EXTENSION "RAIL SPAN"IS DEFINED AS LEVELING SPACER.SEE DETAIL(S) "UR40-D01,""UR40-DOB,""UR40-D09,"& DISTANCE BETWEEN "UR40-D10,"FOR DETAILS AND ROOF ATTACHMENTS LIMITATIONS. \ A \ "STRUCTURAL MEMBER(S)" MAY REFER TO RAFTERS,PURLINS, BEAMS,OR OTHER STRUCTURAL, LOAD-CARRYING MEMBERS SNAPNRACK MID CLAMP,TYP; CLAMP ASSEMBLY SHALL BE SELECTED TO MATCH PV MODULE "MODULE OVERHANG" NOT TO EXCEED 25%OF MODULE LENGTH OR MODULE MANUFACTURERS RECOMMENDATIONS SNAPNRACK ROOF ATTACHMENT LAG SCREWED INTO STRUCTURAL MEMBER. NO FLASHING SHOWN FOR CLARITY. �I Sunrun South LLC DESIGNER: M.Affentranger SCALE,. DNS PART NUMBER: DESCRIPTION: REV << (� �_ M," " °°°M ��"" DRAFTER: M.Affentranger UR40-DO6 UR-40 TYPICAL LAYOUT A µ, DATE: 11/30/2017 �^ APPROVED BY: G.McPheeters